| Product Type | Soft starter for three-phase motors |
| Brand | Siemens |
| Model | 3RW4443-6BC35 |
| Rated Operational Voltage | 200-480 V AC |
| Rated Motor Power | 22 kW at 400 V AC |
| Rated Operational Current | 45 A |
| Control Supply Voltage | 24 V AC/DC |
| Connection Type | Screw terminals |
| Number of Poles | Three-phase (3 poles) |
| Protection Class | IP20 |
| Dimensions (W x H x D) | 145 mm x 300 mm x 230 mm |
| Weight | Approx. 4.5 kg |
| Mounting Type | Wall or panel mounting |
| Operating Temperature Range | -25 °C to +60 °C |
| Display | Integrated graphic display |
| Functions | Soft start, soft stop, overload protection, phase failure detection |
| Maintenance | Periodic inspection of terminals and cooling |
| Cleaning | Use dry cloth, avoid solvents |
| Safety | Thermal overload protection, motor protection |
| Spare Parts and Repairability | User-replaceable fan and control module |
| General Information | Instructions manual available in PDF (255 pages) |
Frequently Asked Questions - 3RW4443-6BC35 SIEMENS
What is the rated current of the 3RW4443-6BC35 soft starter?
The rated operational current is 45 A at a supply voltage of 400 V AC. This allows the device to control motors with a rated power of approximately 22 kW.
Which control voltage does the 3RW4443-6BC35 require?
The control supply voltage for this model is 24 V AC/DC. Make sure to connect it to a suitable power source for the logic and display functions.
How do I set the start ramp time on the device?
Use the integrated display and buttons to access the parameter menu. Navigate to the 'Starting Ramp' setting and adjust the ramp time from 1 to 20 seconds. Confirm with the Enter button.
What protection functions are included?
The device includes overload protection, phase failure detection, overcurrent protection, and motor protection via a built-in electronic relay.
Can I clean the device with water or a solvent?
No, use only a dry cloth to remove dust. Avoid water, aerosols, or solvents to prevent electrical shorts and component damage.
Is the soft starter suitable for single-phase motors?
No, this model is designed for three-phase induction motors only. Using it on a single-phase motor may damage the unit.
What do I do if the display shows an alarm?
Check the error code shown on the display and refer to the manual's fault matrix. Common causes include phase loss or overtemperature. Reset the alarm after clearing the fault.
How often should maintenance be performed?
Perform a visual inspection of the power terminals and cooling fan every 6 months. Replace the fan if it fails to prevent overheating.
Where can I find the spare parts for this soft starter?
Genuine spare parts such as the control module and fan assembly are available through Siemens service partners. Use only original components for repairs.
Can I download the user manual online?
Yes, the user manual is available as a PDF file on notice-facile.com. It includes 255 pages in English and can be downloaded for free.
User questions about 3RW4443-6BC35 SIEMENS
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
No questions yet. Be the first to ask one.
Download the instructions for your Uncategorized in PDF format for free! Find your manual 3RW4443-6BC35 - SIEMENS and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. 3RW4443-6BC35 by SIEMENS.