Product Type 3-Phase Power Quality Analyzer
Brand Extech
Model PQ34-30
Display Backlit LCD with analog bargraph
Measuring Parameters AC/DC Voltage, AC/DC Current, True RMS, Power (W), Reactive Power (VAR), Power Factor, Phase Angle, Harmonics up to 50th order
Clamp Jaw Size 50mm (2000A AC/DC)
Voltage Range 0.1V to 600V AC/DC
Current Range 0.1A to 2000A AC/DC
Frequency Range 40Hz to 70Hz
Accuracy ±0.5% typical (voltage/current)
Data Logging Built-in memory for up to 32,000 readings
Interface USB and optional Bluetooth for PC connectivity
Power Supply 4 x AAA batteries or AC adapter (included)
Dimensions Approx. 250 x 100 x 50 mm
Weight Approx. 500 g
Operating Temperature 0°C to 50°C
Storage Temperature -10°C to 60°C
Safety Rating CAT III 600V
Certifications CE approved
Included Accessories Test leads, alligator clips, carrying case, user manual, software CD
Maintenance Wipe with dry lint-free cloth; keep connectors clean
Cleaning Do not use solvents or abrasive cleaners
Warranty 1-year limited warranty
Country of Origin China
Manual Language English

Frequently Asked Questions - PQ34-30 Extech

What measurements can the Extech PQ34-30 perform?
The Extech PQ34-30 is a 3-phase power quality analyzer that measures AC/DC voltage, AC/DC current, true RMS values, active power (W), reactive power (VAR), apparent power (VA), power factor, phase angle, and harmonics up to the 50th order. It is suitable for single-phase, split-phase, and three-phase systems.
How do I connect the instrument to a power source for measurement?
For voltage measurements, use the included test leads and connect the inputs to the voltage terminals (typically L, N, and Earth). For current measurements, clamp the AC/DC current probe around the conductor. Ensure the connections are secure and meet the safety category requirements before powering on.
Is the PQ34-30 suitable for three-phase systems?
Yes, the PQ34-30 is designed for 3-phase power analysis. It can calculate parameters for balanced or unbalanced loads and supports both 3-phase 3-wire and 3-phase 4-wire configurations. The analyzer automatically performs phase-to-phase and phase-to-neutral calculations.
How do I perform a harmonic analysis?
To perform harmonic analysis, connect the meter to the power source, press the HARMONICS button, and select the phase or parameter of interest. The display shows the harmonic spectrum as a bar graph or numerical table, including THD and individual harmonic percentages up to the 50th order.
Can I record data over time?
Yes, the PQ34-30 has a data logging feature that can record measurement readings at user-defined intervals. It can store up to 32,000 records in internal memory. You can start, stop, and retrieve logged data using the front panel buttons or via the PC software.
How do I connect the meter to a PC?
The PQ34-30 connects to a PC via the USB port. Install the included software, use the USB cable to link the meter to your computer, and select the appropriate COM port. Once connected, you can configure logging, download data, and generate reports.
What safety precautions should I take?
Always follow the safety warnings in the user manual. Use the meter only within its rated category (CAT III 600V). Inspect test leads and probes for damage before use. Do not work on live circuits if the meter has a low battery. Use appropriate personal protective equipment (PPE) when working with electricity.
How do I clean and maintain the device?
Clean the external surfaces with a soft, dry cloth. For stubborn dirt, use a cloth slightly dampened with water. Avoid using solvents, abrasives, or harsh chemicals that could damage the housing. Keep the AC/DC clamp jaws clean and free of debris for accurate readings.
How often should the meter be calibrated?
To ensure accuracy, Extech recommends calibrating the PQ34-30 at least once a year. If the meter is used frequently or under harsh conditions, calibration may be needed more often. Contact an accredited calibration laboratory or Extech service center for calibration.
What do I do if the display shows no reading?
If the display is blank, check whether the batteries are installed correctly and have sufficient voltage. If using an AC adapter, verify the adapter is connected. Ensure the test leads are properly inserted into the input terminals. If the problem persists, contact Extech technical support.

User questions about PQ34-30 Extech

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Measuring equipment in PDF format for free! Find your manual PQ34-30 - Extech and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. PQ34-30 by Extech.

USER MANUAL PQ34-30 Extech

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : Extech

Model : PQ34-30

Category : Measuring equipment