| Product type | Digital thermometer |
| Brand | Innoliving |
| Model | MD-CR.W00 |
| Intended use | Human body temperature measurement |
| Measurement range | 32.0 °C to 42.0 °C |
| Display accuracy | ±0.1 °C between 35.5 °C and 42.0 °C |
| Display type | Liquid crystal display (LCD) |
| Measurement time | Approximately 60 seconds |
| Units of measurement | °C / °F selectable |
| Memory function | Stores last measured value |
| Fever alarm | Acoustic signal when temperature is above 37.8 °C |
| Auto power off | Yes, after approximately 10 minutes |
| Battery type | 1 × LR41 button cell, 1.5 V |
| Dimensions | 127 × 22 × 15 mm |
| Weight | 15 g (including battery) |
| Material | ABS plastic, stainless steel sensor |
| Water resistance | Waterproof probe for easy cleaning |
| Cleaning method | Wipe with a soft cloth dampened with 70% isopropyl alcohol |
| Safety standards | Complies with medical device directives for home use |
| Battery replacement | User-replaceable; slide open battery compartment |
| Operating environment | 10 °C to 40 °C, relative humidity up to 85% |
Frequently Asked Questions - MD-CR.W00 Innoliving
How do I switch between Celsius and Fahrenheit?
On your Innoliving MD-CR.W00, press and hold the power button for about 3 seconds until °C or °F appears. Release the button to confirm your choice. The selected unit will be saved for future measurements.
How should I measure my temperature under the armpit?
Place the probe tip in the armpit, keep your arm close to your body, and wait for the beep. This usually takes about 60 seconds. Ensure the armpit is dry before measurement to obtain an accurate result.
What does the fever alarm indicate?
When the measured temperature is higher than 37.8 °C, the thermometer emits a continuous beeping tone for a few seconds to indicate a possible fever.
How do I clean my thermometer after use?
Wipe the probe and body with a soft cloth dampened with 70% isopropyl alcohol. Do not immerse the thermometer in water or other liquids.
When should I replace the battery?
Replace the battery when the low-battery symbol appears on the display. Use a new LR41 button cell, open the battery compartment with a small screwdriver, and insert the battery with the correct polarity.
Can I use the thermometer in the mouth and rectally?
The same probe can be used for oral, axillary or rectal measurement, depending on the model. For accurate readings, always measure in the same place and follow the hygiene instructions.
What accuracy can I expect from this thermometer?
The MD-CR.W00 offers ±0.1 °C accuracy in the range 35.5 °C to 42.0 °C, which is suitable for home medical monitoring.
Why is there an M on the display?
The letter M indicates that the thermometer is in memory mode, showing the last measured temperature. Press the power button to return to measurement mode.
How long does the thermometer stay on after a reading?
After a measurement, the device will automatically turn off after approximately 10 minutes to save battery. You can also press the power button to switch it off manually.
What should I do if the thermometer gets damaged?
Do not attempt to repair it yourself. Contact the Innoliving after-sales service or an authorised repair centre. The battery can be replaced by the user, but the electronic circuit should only be inspected by qualified personnel.