Carbon CR12U51001 - Uncategorized CyberPower - Free user manual and instructions
Find the device manual for free Carbon CR12U51001 CyberPower in PDF.
Pick your language and provide your email: we'll send you a specifically translated version.
| Product Type | Rack-Mount Power Distribution Unit (PDU) |
| Brand | CyberPower |
| Model | Carbon CR12U51001 |
| Number of Outlets | 12 |
| Outlet Type | NEMA 5-15R |
| Input Plug Type | NEMA L5-15P |
| Input Voltage | 120V AC |
| Maximum Current | 15A |
| Maximum Power Rating | 1800W |
| Form Factor | 1U Rack-Mount |
| Mounting | Horizontal, 19-inch rack |
| Chassis Material | Heavy-duty aluminum |
| Dimensions (W x D x H) | 483 x 89 x 44 mm |
| Weight | 2.6 kg (5.7 lbs) |
| Input Cord Length | 2.4 m (8 ft) |
| Surge Protection | 1080 Joules |
| Circuit Breaker | 15A resettable |
| LED Indicators | Power and overload warning |
| Operating Temperature | 0°C to 35°C |
| Certifications | UL, cUL, NOM |
| Cleaning Instructions | Wipe with a dry cloth; avoid liquids |
| Repairability | No user-serviceable parts; contact support |
Frequently Asked Questions - Carbon CR12U51001 CyberPower
What is the CyberPower Carbon CR12U51001?
The CyberPower Carbon CR12U51001 is a rack-mount power distribution unit (PDU) designed for data centers and network racks. It provides 12 NEMA 5-15R outlets in a compact 1U form factor.
How many outlets does this PDU have and what type?
It has 12 outlets of type NEMA 5-15R, suitable for standard 120V equipment.
What is the input plug type?
The input plug is a NEMA L5-15P locking plug that securely connects to a 15A, 120V circuit.
Can this PDU be mounted in a standard rack?
Yes, it is designed for horizontal 1U mounting in a standard 19-inch rack. Mounting hardware is typically included or available.
Does this PDU provide surge protection?
Yes, it includes 1080 joules of surge protection to shield connected devices from spikes and transients.
How do I reset the circuit breaker?
If overload occurs, the built-in 15A resettable circuit breaker will trip. Disconnect some devices and press the breaker button to reset.
What is the maximum load I can connect?
The maximum load is 15A (1800W) at 120V. Do not exceed this rating to avoid tripping the breaker or causing damage.
Can I daisy-chain multiple PDUs?
No, daisy-chaining is not recommended. Connect each PDU to a separately protected circuit to avoid overloading.
How should I clean and maintain this PDU?
Disconnect power before cleaning. Use a soft, dry cloth to wipe the exterior. Do not use liquids or solvents.
What should I do if the PDU is not working?
Check the circuit breaker and input power. If the unit still fails, contact CyberPower technical support for troubleshooting. The unit has no user-serviceable parts.