PDU81008 - Power Strip CyberPower - Free user manual and instructions
Find the device manual for free PDU81008 CyberPower in PDF.
Pick your language and provide your email: we'll send you a specifically translated version.
| Product Type | Switched Power Distribution Unit (PDU) |
| Brand | CyberPower |
| Model Number | PDU81008 |
| Mounting Type | 1U Rackmount |
| Number of Outlets | 8 individually switched NEMA 5-15R outlets |
| Input Plug | NEMA 5-15P with 10 ft (3 m) power cord |
| Input Voltage | 120V AC |
| Maximum Current | 15A |
| Max Power Rating | 1800W (120V/15A) |
| Remote Management | Ethernet RJ45 port with web-based control |
| Switching Control | Individual outlet on/off via web interface or front panel |
| Display | Digital amp meter with LED indicators |
| Protection | Overload circuit breaker and surge protection |
| Dimensions (LxWxH) | 17.5 x 5.5 x 1.75 inches (44.5 x 14 x 4.4 cm) |
| Weight | 6.5 lbs (2.9 kg) |
| Operating Temperature | 32°F to 104°F (0°C to 40°C) |
| Humidity Range | 5% to 90% RH, non-condensing |
| Maintenance | Wipe with a dry cloth; do not use liquid cleaners |
| Repairability | No user-serviceable parts; contact CyberPower support for service |
Frequently Asked Questions - PDU81008 CyberPower
What is the maximum load capacity of the CyberPower PDU81008?
The maximum load capacity is 1800W at 120V with a maximum current of 15A. Do not exceed this rating to prevent tripping the built-in circuit breaker.
Can I control the outlets remotely?
Yes, the PDU81008 features remote management via an Ethernet connection. You can access the web interface to turn individual outlets on or off from anywhere on the network.
How do I set up the network connection?
Connect an Ethernet cable from your router to the RJ45 port on the PDU. The device will obtain an IP address via DHCP by default. Use the provided software or documentation to discover its IP address and access the web-based interface.
What type of power plug does it use?
It uses a NEMA 5-15P plug, which is standard for 120V outlets in North America. The unit is rated for 15A input.
Does the PDU81008 provide surge protection?
Yes, it includes surge protection to shield connected equipment from voltage spikes and transient surges.
How can I reset the PDU to factory defaults?
To reset, press and hold the reset button (usually located near the display) for approximately 10 seconds. This restores all network and outlet settings to factory defaults.
Is the PDU81008 suitable for 230V power systems?
No, the PDU81008 is specifically designed for 120V AC systems. It should not be connected to 230V outlets as this could damage the unit and connected equipment.
What is the operating temperature range?
The recommended operating temperature is 32°F to 104°F (0°C to 40°C) with a non-condensing humidity of 5% to 90%.
Can I mount the PDU horizontally or vertically?
The PDU81008 is designed for 1U rack mounting in a standard 19-inch server rack. It can also be placed on a shelf or mounted vertically with optional brackets, but horizontal rack installation is typical.
How do I update the firmware on the PDU?
Access the web interface, navigate to the firmware update section, and upload the latest firmware file downloaded from the CyberPower support website. Follow the on-screen instructions carefully to avoid interrupting the update.
User questions about PDU81008 CyberPower
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
No questions yet. Be the first to ask one.
Download the instructions for your Power Strip in PDF format for free! Find your manual PDU81008 - CyberPower and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. PDU81008 by CyberPower.