AT-4004-A - Uncategorized Amprobe - Free user manual and instructions
Find the device manual for free AT-4004-A Amprobe in PDF.
Pick your language and provide your email: we'll send you a specifically translated version.
| Brand | Amprobe |
| Model | AT-4004-A |
| Product Type | Wire and circuit tracer kit |
| Intended Use | Locating wires, identifying circuit breakers, and detecting live cables |
| Receiver Dimensions | Approximately 210 x 50 x 30 mm |
| Transmitter Dimensions | Approximately 120 x 60 x 25 mm |
| Total Weight | Approximately 500 g including batteries |
| Power Source | 2 x 9V alkaline batteries (receiver and transmitter) |
| Display | LED indicators and audible tone |
| Non-Contact Voltage Detection | Yes, detects AC voltage from 12 to 600 V |
| Wire Tracing Range | Up to 2 meters in wall or conduit |
| Continuity Testing | Integrated continuity tester with buzzer |
| Circuit Breaker Finder | Identifies correct breaker without disconnecting power |
| Safety Rating | CAT III 300V per IEC 61010 |
| Operating Temperature | 0°C to 40°C |
| Storage Temperature | -20°C to 60°C |
| Cleaning | Wipe with a dry, clean cloth; do not use solvents |
| Battery Replacement | Replace batteries when low battery indicator lights |
| Accessories Included | Transmitter, receiver, test leads, pouch |
| Compliance | CE, RoHS |
| Warranty | 1 year limited warranty |
Frequently Asked Questions - AT-4004-A Amprobe
How do I use the AT-4004-A to trace a wire in my wall?
Connect the transmitter to the target wire via the test leads or clamp. Turn on the receiver and select the wire tracing mode. Sweep the receiver along the wall to follow the signal. The signal strength indicator and audible tone help pinpoint the exact location.
What types of cables can I trace with this device?
The AT-4004-A can trace live or dead wires in walls, floors, and ceilings, as well as telephone, data, and coaxial cables when using the appropriate mode.
How can I identify the correct circuit breaker for an outlet?
Plug the transmitter into the outlet and hold the receiver near each breaker in the panel. The breaker that produces the loudest tone and strongest signal is the correct one.
How does the non-contact voltage detection work?
Use the receiver's voltage detection mode and bring it close to an insulated wire. The tip glows and beeps when AC voltage between 12 and 600 V is present.
What safety precautions should I take while using the tracer?
Always observe CAT III 300V safety ratings. Use insulated tools and wear personal protective equipment. Do not touch exposed conductors and follow local electrical codes.
How do I replace the batteries?
Locate the battery compartments on the back of both the transmitter and receiver. Open the screws, remove the old 9V batteries, insert new ones, and close the compartments securely.
Can I trace wires in energized circuits?
Yes, the device supports tracing on energized circuits. The transmitter can handle voltages up to 300V AC in certain modes, always verify the manual for your specific application.
How do I test continuity with the AT-4004-A?
Connect the test leads to the continuity input and touch the probes to the ends of the circuit. A continuous beep indicates continuity below a certain resistance threshold.
What is the maximum tracing range of the AT-4004-A?
The receiver can detect the transmitter's signal through walls and conduits at depths up to 2 meters in ideal conditions. Interference and material type can affect the range.
How should I clean and maintain the tracer?
Wipe the unit with a dry, lint-free cloth after use. Do not use abrasive cleaners or solvents. Keep the device in its protective pouch when not in use. Check batteries regularly to prevent leakage.
User questions about AT-4004-A Amprobe
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
No questions yet. Be the first to ask one.