| Product Type | Industrial digital display |
| Brand | IFM |
| Model | EC0406 |
| Display Type | 7-segment LED |
| Number of Digits | 6 |
| Character Height | 10 mm |
| Supply Voltage | 24 V DC (18...30 V DC) |
| Current Consumption | ≤ 50 mA |
| Input Signal | NPN / PNP, pulse |
| Functions | Counting, frequency and time measurement |
| Dimensions (W × H × D) | 48 × 24 × 75 mm |
| Weight | 80 g |
| Housing | Industrial plastic, front panel sealed |
| Protection Rating | IP65 (front only) |
| Operating Temperature | -10 ... +60 °C |
| Electrical Connection | Screw terminals, ≤ 2.5 mm² |
| Cleaning | Wipe with a dry, lint-free cloth |
| Maintenance | No regular maintenance required |
| Safety | Observe national safety and installation regulations |
| Spare Parts | No user-replaceable parts; contact service |
| Repairability | Repairs only by IFM authorized service |
Frequently Asked Questions - EC0406 IFM
How do I install the EC0406 display?
Mount the display in a control panel with the provided seal. Connect the supply voltage and input signals to the screw terminals according to the pin assignment diagram in the manual. Ensure the front panel is properly sealed to maintain the IP65 protection.
What voltage should I supply to the EC0406?
The EC0406 operates with a 24 V DC supply (nominal range 18...30 V DC). Use a regulated power source to avoid damage due to voltage spikes or reverse polarity.
How can I clean the front panel?
Clean the front panel with a soft, dry, lint-free cloth. For stubborn dirt, use a slightly damp cloth with a mild detergent. Avoid abrasive cleaners, solvents, or excessive moisture.
Can the EC0406 be used outdoors?
The front panel is IP65 rated, meaning it is protected against dust and low-pressure water jets. However, the rear housing is not fully sealed, so the display should be installed in an enclosed enclosure if used outdoors.
How do I set a preset value?
Use the front keys to enter the programming mode. Navigate to the preset parameter, adjust the value using the arrow keys, and confirm. The display will then count and trigger an output when the preset is reached.
What is the input signal compatibility?
The EC0406 accepts NPN (open collector) and PNP pulse signals. It can also be configured for single or quadrature counting. Refer to the manual for the correct input wiring and signal levels.
How do I fix a blank display?
First, check the supply voltage at the terminals. If power is present, verify the display is not in sleep mode or that the contrast/backlight setting is not turned down. A defective unit may show no display even with power; contact IFM service.
Is the display protected against dust and water?
Yes, the front panel meets IP65 protection, meaning it is dust-tight and protected against water jets from any direction. The rear connection area requires proper installation to maintain this rating.
How can I reset the counter?
Press and hold the reset key for at least 3 seconds to clear the current count. Alternatively, you can assign a external reset input signal if configured in the programming menu.
Where can I find the user manual?
The user manual is available as a free PDF download on the product page. It includes detailed installation, wiring, and programming instructions. You can also request a printed copy from IFM support.
User questions about EC0406 IFM
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
No questions yet. Be the first to ask one.
Download the instructions for your Display in PDF format for free! Find your manual EC0406 - IFM and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. EC0406 by IFM.