Type of product Copper Compression Lug
Brand Panduit
Model LCA2/0-12H-X
Cable size (AWG) 2/0
Stud size 1/2 inch (12H)
Material High-conductivity copper
Finish Tin-plated
Barrel type Standard
Connector type One-hole lug
Voltage rating Up to 600 V
Overall length 89 mm (3.5 in)
Width 25 mm (1 in)
Weight 45 g (0.1 lb)
Installation method Crimp with approved tool
Operating temperature -40 °C to 90 °C
Standards UL 486A-486B, CSA C22.2
RoHS compliant Yes
Maintenance Wipe with dry cloth
Safety Disconnect power before use

Frequently Asked Questions - LCA2/0-12H-X Panduit

What is the Panduit LCA2/0-12H-X used for?
It is a copper compression lug used to terminate 2/0 AWG copper cable to electrical panels, breakers, transformers, and bus bars, ensuring a secure and low-resistance connection.
What cable size does the LCA2/0-12H-X accommodate?
It accommodates a 2/0 AWG stranded copper conductor, commonly used in industrial and commercial power installations.
What size stud does the LCA2/0-12H-X fit?
The lug has a hole designed for a 1/2-inch (12.7 mm) bolt or stud, making it compatible with standard American electrical hardware.
Which crimping tool should I use with the LCA2/0-12H-X?
Use a Panduit crimping tool from the CT series, such as the CT-720 or CT-2930, equipped with the correct die for 2/0 AWG copper lugs. Always verify the die code on the barrel.
Can the LCA2/0-12H-X be used with aluminum conductors?
No, it is specifically fabricated for copper conductors. For aluminum, use a dual-rated lug or an aluminum-compression lug like Panduit's LAA series.
Is the LCA2/0-12H-X resistant to corrosion?
Yes, it has a tin-plated copper surface that protects against oxidation and galvanic corrosion, extending service life in humid environments.
What is the maximum operating temperature?
The lug is rated for continuous operation from -40 °C to 90 °C, which covers most indoor and outdoor power applications.
Do I need to apply heat shrink or insulation after crimping?
Heat shrink is not required for the connection itself, but you may add an insulating heat-shrink tube for extra protection against accidental contact. The lug is designed for bare termination.
Can the lug be reused after being crimped?
Reuse is not recommended. Once crimped, the metal is permanently deformed. For safety, always use a new lug when re-terminating a cable.
How should I maintain the lug during its service life?
Periodically inspect for signs of overheating, corrosion, or looseness. Clean with a dry lint-free cloth and, if necessary, use isopropyl alcohol. Do not use abrasive pads.

User questions about LCA2/0-12H-X Panduit

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Uncategorized in PDF format for free! Find your manual LCA2/0-12H-X - Panduit and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. LCA2/0-12H-X by Panduit.

USER MANUAL LCA2/0-12H-X Panduit

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : Panduit

Model : LCA2/0-12H-X

Category : Uncategorized