LCA2-56F-Q - Uncategorized Panduit - Free user manual and instructions
Find the device manual for free LCA2-56F-Q Panduit in PDF.
Pick your language and provide your email: we'll send you a specifically translated version.
| Product Type | Copper Compression Lug |
| Series | LCA2 |
| Material | High-Conductivity Copper |
| Wire Size | 56 mm² (approx. 1/0 AWG) |
| Number of Holes | Two |
| Stud Size | 1/2 inch (M12) |
| Finish | Tin-Plated |
| Barrel Shape | Flared barrel for easy wire insertion |
| Application | Electrical grounding and power connections |
| Compatible Conductors | Fine-stranded copper conductors |
| Mounting Type | Two-hole base for secure installation |
| Standards | UL Listed, CSA Certified |
| Operating Temperature | -40°C to +125°C |
| Voltage Rating | Up to 600V |
| Barrel Inside Diameter | 10.5 mm |
| Barrel Length | 35 mm |
| Overall Length | 95 mm |
| Width | 28 mm |
| Hole Spacing | 44.5 mm (1.75 in) |
| Weight | Approx. 0.15 kg |
| Color Code | Blue (for 56 mm²) |
| RoHS Compliant | Yes |
Frequently Asked Questions - LCA2-56F-Q Panduit
What is the Panduit LCA2-56F-Q used for?
The LCA2-56F-Q is a two-hole copper compression lug designed for terminating 56 mm² copper conductors in power distribution, grounding, and electrical connection applications.
What crimping tool is recommended for this lug?
A standard hydraulic or manual compression tool with the correct die for 56 mm² lugs is recommended. Panduit offers tools like the CT-3000 series, or equivalent dies for a 12-ton crimper.
Can the LCA2-56F-Q be used with aluminum wire?
No, this lug is specially engineered for copper conductors. Using it with aluminum wire may lead to improper connections and safety hazards. Use aluminum-rated lugs for aluminum cables.
What is the temperature rating of this lug?
The operating temperature range is -40°C to +125°C, making it suitable for a wide variety of indoor and outdoor environments.
How do I prepare the wire before crimping?
Strip the insulation to the barrel length, insert the bare conductor fully into the barrel, and ensure it is clean and free from oxidation. For fine-stranded wire, twisting may help.
Is the lug tin-plated for corrosion resistance?
Yes, the copper lug has a tin plating that enhances corrosion resistance, improves conductivity, and provides compatibility with other tinned or copper components.
What is the center-to-center distance between the mounting holes?
The hole spacing is 44.5 mm (1.75 inches), which fits standard 2-hole mounting pads on busbars and equipment.
Can this lug be used in high-vibration environments?
Yes, the two-hole mounting design provides a mechanically secure connection that resists vibration, and proper crimping ensures a reliable electrical joint.
What voltage rating is this lug suitable for?
The lug is rated for applications up to 600 volts, which covers most industrial and commercial electrical systems.
Does this lug comply with industry standards?
Yes, the LCA2-56F-Q is UL Listed and CSA Certified, ensuring it meets rigorous safety and performance requirements.