Type of product Digital automatic blood pressure monitor (sphygmomanometer)
Measurement method Oscillometric
Measurement site Upper arm
Display Large LCD with date and time
Measurement range Pressure: 60-260 mmHg, Pulse: 40-200 bpm
Accuracy Pressure: ±3 mmHg, Pulse: ±5%
Cuff size Fits arm circumference 22-32 cm (standard), optional larger cuff
Memory 2 users × 90 readings
Irregular heartbeat detection Yes, alerts for arrhythmia
WHO indicator Color scale for blood pressure classification
Average function Shows average of last 3 readings
Power source 4 × AA batteries (1.5V) or AC adapter (6V, 600mA)
Battery life Approximately 300 measurements
Auto shut-off Yes, after 1 minute of inactivity
Low battery indicator Yes
Dimensions 152 × 106 × 58 mm (approx.)
Weight 265 g (without batteries)
Cleaning Wipe with a soft, dry cloth; do not immerse in water
Storage temperature -20°C to 55°C
Operating temperature 10°C to 40°C
Certification CE and ISO 13485 compliant
Included accessories Arm cuff, instruction manual, storage pouch
Repair / parts Only authorized service center; cuff is replaceable

Frequently Asked Questions - GP300 G-Tech

How do I position the cuff on my arm?
Place the cuff on your bare upper arm, about 2-3 cm above the elbow. The air tube should run along the inside of your arm. Position the cuff so that the artery marker aligns with the main artery. Wrap it snugly, but you should be able to slide one finger between the cuff and your arm.
What does the irregular heartbeat symbol mean?
The icon indicates that an irregular heartbeat was detected during the measurement. This may be a sign of arrhythmia. If it appears frequently, consult your doctor. This feature is not a substitute for a medical diagnosis.
When is the best time to measure blood pressure?
Measure at the same time each day, ideally in the morning before taking medication or eating, and in the evening before bed. Rest for 5 minutes beforehand. Avoid caffeine, smoking, and exercise for 30 minutes before a reading.
How do I replace the batteries?
Open the battery compartment on the side or back of the device. Remove old batteries and insert four AA batteries of the same type, respecting polarity marked inside. Use alkaline or lithium batteries for longer life. Do not mix old and new batteries.
Can I use the monitor with an AC adapter?
Yes, you can use a 6V DC, 600mA AC adapter with a compatible connector. Plug the adapter into the device and a power outlet. The monitor automatically switches to adapter power when connected. Batteries continue to power the device if the adapter is disconnected.
How many readings can be stored in memory?
The monitor stores up to 90 readings per user for two users, giving a total of 180 readings. Each reading includes the date, time, systolic and diastolic pressure, and pulse. You can easily switch between user memories.
Why do my readings vary between measurements?
Blood pressure varies naturally throughout the day. To get consistent values, measure under the same conditions: same arm, same time, and after resting. Avoid talking or moving during measurement. Also wait 3-5 minutes between readings.
How should I clean and maintain the monitor?
Use a soft, dry cloth to wipe the device and cuff. Do not use water, solvents, or abrasive cleaners. Never immerse the device or cuff in liquid. Store it in a dry, cool place, away from direct sunlight and extreme temperatures.
What do the error messages or symbols mean?
Common symbols include Err (improper operation or air leak), E1/E2 (cuff or air pressure issues), and the heart icon (irregular heartbeat). Refer to the manual's error table for exact meanings. Most errors are resolved by repositioning the cuff and staying still.
Does the device work for people with pacemakers?
This monitor is not recommended for people with pacemakers or other implanted electronic devices, as the oscillometric measurement could interfere. If you rely on such a device, consult your physician before using an automatic blood pressure monitor.

User questions about GP300 G-Tech

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Sphygmomanometer in PDF format for free! Find your manual GP300 - G-Tech and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. GP300 by G-Tech.

USER MANUAL GP300 G-Tech

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : G-Tech

Model : GP300

Category : Sphygmomanometer