GREE

GMV-ND12A/A-T(U) - Air conditioner GREE - Free user manual and instructions

Find the device manual for free GMV-ND12A/A-T(U) GREE in PDF.

📄 22 pages English EN Download 💬 AI Question 10 questions ⚙️ Specs
Notice GREE GMV-ND12A/A-T(U) - page 8
Pick your language and provide your email: we'll send you a specifically translated version.
Product Type Air conditioner (indoor unit for VRF multi-split system)
Brand Gree
Model GMV-ND12A/A-T(U)
Category Air conditioner
Cooling Capacity 3.5 kW (12,000 BTU/h)
Heating Capacity 4.0 kW (13,650 BTU/h)
Power Supply 220–240 V ~ 50 Hz
Airflow Rate 450 m³/h (high speed)
Sound Pressure Level 32 dB(A) (high), 24 dB(A) (low)
Dimensions (W×H×D) 840 × 210 × 450 mm
Net Weight 21 kg
Refrigerant R410A
Indoor Unit Type Ducted concealed ceiling unit
Control Method Wired controller or centralised VRF control system
Air Filter Washable antibacterial filter
Condensate Drain Gravity drain with optional condensate pump
Static Pressure 30 Pa (default)
Installation Requires professional installation and refrigerant piping
Maintenance Accessible panel for easy filter cleaning and service
Safety Features Overcurrent protection, overheating protection, auto-restart
Operating Temperature (Cooling) -5 °C to 48 °C
Operating Temperature (Heating) -15 °C to 24 °C
Compliance CE, RoHS, ERP

Frequently Asked Questions - GMV-ND12A/A-T(U) GREE

How do I clean the air filter of the Gree GMV-ND12A/A-T(U)?
Turn off the unit, open the access panel, remove the filter, vacuum or rinse with water, dry completely before reinstalling. Clean every 2-4 weeks.
What refrigerant does this air conditioner use?
The unit uses R410A refrigerant. Always contact a certified technician for handling.
Can I control the unit with an infrared remote control?
This ducted indoor unit is designed for a wired controller or a central VRF control system. It does not include an infrared remote by default; an optional wired controller can be installed.
What are the recommended maintenance intervals for the air conditioner?
Clean the filters monthly during peak season and have a professional inspection of the refrigerant circuit and coils annually.
Is the heating function available at very low outdoor temperatures?
The unit can operate in heating mode down to -15 °C outdoor temperature, but performance may decrease as the temperature drops.
What is the default static pressure of the GMV-ND12A/A-T(U)?
The default static pressure is 30 Pa, which can be adjusted via the controller for ducting requirements.
How do I reset the unit after a power failure?
The unit has an auto-restart feature. After power returns, it automatically resumes the previous operation mode.
What type of installation is required for this indoor unit?
The GMV-ND12A/A-T(U) is a ducted concealed ceiling unit. It must be installed by a professional with access to refrigerant piping and drain lines.
Can I integrate this air conditioner into a smart home system?
With a suitable adapter or gateway, the VRF system can be integrated into some smart home platforms. Check with your installer for compatible options.
What should I do if the unit displays an error code?
Refer to the user manual's error code table. Turn off the unit and contact a certified Gree service center for diagnosis and repairs.

User questions about GMV-ND12A/A-T(U) GREE

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Air conditioner in PDF format for free! Find your manual GMV-ND12A/A-T(U) - GREE and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. GMV-ND12A/A-T(U) by GREE.

USER MANUAL GMV-ND12A/A-T(U) GREE

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : GREE

Model : GMV-ND12A/A-T(U)

Category : Air conditioner