ERV100S - Air Conditioning BROAN - Free user manual and instructions
Find the device manual for free ERV100S BROAN in PDF.
Pick your language and provide your email: we'll send you a specifically translated version.
| Product Type | Energy Recovery Ventilator (ERV) |
| Model | ERV100S |
| Brand | Broan |
| Application | Balanced residential ventilation with heat and moisture recovery |
| Airflow Capacity | 100 CFM (cubic feet per minute) |
| Dimensions (H x W x D) | 20 x 20 x 16 inches |
| Weight | 45 lbs |
| Power Supply | 120 V, 60 Hz, 1.5 A |
| Power Consumption | 180 watts |
| Duct Connections | 6-inch round ducts (2 supply, 2 exhaust) |
| Recovery Efficiency | Up to 80% sensible heat recovery |
| Filter Type | Washable electrostatic or disposable MERV-6 |
| Mounting | Ceiling or wall mount with brackets |
| Controls | Low voltage wall control (included) or optional multi-speed/IAQ controls |
| Defrost Strategy | Automatic defrost cycle for cold climates |
| Certifications | UL listed, HVI certified, Energy Star compliant |
| Maintenance | Clean or replace filters every 3-6 months |
| Safety Features | GFCI protected circuit recommended; auto shut-off if motor stalls |
| Warranty | 5-year limited warranty on parts |
| Repairability | Accessible core, motor, and filters for service; spare parts available via Broan |
Frequently Asked Questions - ERV100S BROAN
What is an ERV and how does it differ from an HRV?
An ERV (Energy Recovery Ventilator) transfers both heat and moisture between incoming and outgoing air streams, while an HRV (Heat Recovery Ventilator) only transfers heat. The ERV100S is an ERV, making it ideal for humid climates.
What are the recommended duct sizes and lengths for the ERV100S?
Use 6-inch round ducts. Maximum total duct length should not exceed 100 feet equivalent length (including fittings). Use balanced duct runs to minimize static pressure.
How often should the filters be cleaned or replaced?
Inspect filters every 3 months. Clean washable filters with mild soap and water; replace disposable filters every 6 months or if damaged.
Can the ERV100S be installed in a cold attic?
Yes, but the unit should be insulated and installed in a conditioned or semi-conditioned space. The automatic defrost cycle protects against freezing in cold climates.
What is the typical noise level of this ERV?
Sound level is approximately 1.0 sone at normal speed, making it very quiet for residential use.
How do I connect the wall control?
The wall control connects via low-voltage thermostat wire (2-4 conductors). Follow the wiring diagram in the manual. Typical configurations use 18-22 gauge wire.
What does the automatic defrost cycle do?
When outdoor temperatures drop below approximately 23°F (-5°C), the ERV enters defrost mode, temporarily closing the outdoor intake to recirculate indoor air and prevent frost buildup on the core.
Can I use a timer to control the ERV?
Yes, you can connect a timer switch (like a humidity sensor or occupancy timer) to the low-voltage control circuit. The unit accepts standard 24VAC signals.
What maintenance is required for the ERV core?
The energy recovery core should be cleaned every 1-2 years. Remove it from the unit and wash with warm water and mild detergent. Allow it to dry completely before reinstalling.
How do I troubleshoot if the ERV stops working?
First, check that power is on and the circuit breaker has not tripped. Verify that the wall control is functioning. Inspect filters and core for blockages. Listen for unusual motor sounds. If still not working, consult the manual's troubleshooting guide or contact Broan customer support.
User questions about ERV100S BROAN
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
No questions yet. Be the first to ask one.
Download the instructions for your Air Conditioning in PDF format for free! Find your manual ERV100S - BROAN and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. ERV100S by BROAN.