RXLG35M2V1B - Air Conditioning DAIKIN - Free user manual and instructions
Find the device manual for free RXLG35M2V1B DAIKIN in PDF.
Pick your language and provide your email: we'll send you a specifically translated version.
| Brand | Daikin |
| Model | RXLG35M2V1B |
| Product Type | Air Conditioner (Split System) |
| Cooling Capacity | 3.5 kW (12,000 BTU/h) |
| Heating Capacity | 4.0 kW (13,600 BTU/h) |
| Power Supply | 230 V ~ 50 Hz |
| Indoor Unit Dimensions (W x H x D) | 795 x 290 x 238 mm |
| Outdoor Unit Dimensions (W x H x D) | 770 x 550 x 285 mm |
| Indoor Unit Weight | 9.5 kg |
| Outdoor Unit Weight | 34.0 kg |
| Refrigerant | R32 |
| Energy Efficiency Class (Cooling) | A++ |
| Energy Efficiency Class (Heating) | A+ |
| Noise Level (Indoor) | 19 - 24 dB(A) |
| Noise Level (Outdoor) | 46 - 48 dB(A) |
| Airflow Rate (High) | 672 m³/h |
| Number of Fan Speeds | 5 |
| Timer Function | 24-hour timer with on/off settings |
| Filter Cleaning Interval | Every 2 weeks |
| Remote Control | Infrared included |
| Operation Modes | Cooling, Heating, Fan, Dehumidification, Auto |
| Safety Features | Auto restart, overheat protection, compressor delay |
Frequently Asked Questions - RXLG35M2V1B DAIKIN
How do I clean the air filters?
Turn off the unit and disconnect power. Open the front panel, remove the filters, and wash them with warm water and mild detergent. Dry thoroughly before reinstalling. Clean every 2 weeks for optimal performance.
What does the error code E7 mean?
Error code E7 typically indicates a communication error between indoor and outdoor units. Check wiring connections and ensure no interference. If persistent, contact a qualified technician.
Can I use the air conditioner for heating in winter?
Yes, this model is a heat pump and provides efficient heating down to outdoor temperatures as low as -15°C. Use the remote to switch to heating mode.
How do I set the timer?
Press the TIMER ON or TIMER OFF button on the remote. Use the +/- buttons to set the desired time. The unit will start/stop automatically at that time. Confirm with SET.
Why is the unit not cooling properly?
Check if the air filter is dirty, ensure doors/windows are closed, verify the set temperature is below room temperature, and inspect the outdoor unit for obstructions. If problem persists, call service.
How often should I service the air conditioner?
Professional maintenance is recommended once a year before peak season. This includes checking refrigerant levels, cleaning coils, and electrical inspections.
Is the remote control replaceable?
Yes, you can order a replacement remote from Daikin or compatible universal remotes. Ensure it supports the ARC series codes. The original model number is usually printed inside the battery cover.
What is the power consumption of this unit?
Cooling: approx. 0.75 kW, Heating: approx. 0.85 kW. Actual consumption varies with usage. The Energy Efficiency Ratio (EER) is 4.7 for cooling.
How do I reset the filter indicator?
After cleaning and reinstalling the filters, press and hold the FILTER RESET button on the indoor unit or remote (if available) for 3 seconds until the indicator turns off.
Can I install the outdoor unit on a balcony?
Yes, but ensure proper air circulation and that it is not enclosed. Leave at least 30 cm of space around the unit. Also, check local noise regulations as outdoor units produce up to 48 dB(A).