Product Type Coating Thickness Gauge
Measurement Range 0 - 5000 µm (0 - 197 mils)
Resolution 0.1 µm (0 - 999.9 µm); 1 µm (≥1000 µm)
Accuracy ±1% of reading + 1 µm
Probe Type Magnetic induction (Fe) and eddy current (NFe)
Substrates Ferrous (Fe) and non-ferrous (NFe) metals
Display LCD with backlight
Data Storage Up to 500 readings
Statistics Min, Max, Average, Standard Deviation
Calibration Zero and foil calibration
Power Supply 2 x AA batteries (1.5V each)
Battery Life Approximately 50 hours of continuous use
Auto Power Off Yes, after 5 minutes of inactivity
Dimensions 126 x 68 x 30 mm
Weight 160 g (including batteries)
Operating Temperature 0°C to 50°C (32°F to 122°F)
Storage Temperature -10°C to 60°C (14°F to 140°F)
Humidity 20% to 80% RH (non-condensing)
Protection Class IP54 (splash and dust resistant)
Included Accessories Probe, calibration foils, carrying case, manual
Maintenance Clean probe tip with soft cloth; store in dry place
Safety Use only as intended; avoid contact with solvents
Spare Parts / Repairability Replaceable probe and batteries; contact PCE Instruments

Frequently Asked Questions - CT 5000H PCE Instruments

What is the measurement range of the CT 5000H?
The CT 5000H measures coating thickness from 0 to 5000 µm (0 to 197 mils).
How do I calibrate the device?
Calibration is performed using the included zero plate and calibration foils. Follow the calibration procedure in the manual: first zero on the substrate, then adjust with a known thickness foil.
What types of substrates can it measure?
It works on both ferrous (iron/steel) and non-ferrous (aluminum, copper, brass) metal substrates using magnetic induction and eddy current principles.
How many readings can be stored?
The device can store up to 500 readings in memory, accessible via the menu.
What batteries does it use and how long do they last?
It uses two AA batteries (1.5V). Battery life is approximately 50 hours of continuous operation.
Can the probe be replaced?
Yes, the probe is replaceable. Contact PCE Instruments for a suitable replacement.
How do I clean the device?
Wipe the probe tip and housing with a soft, dry cloth. Do not use solvents or abrasive cleaners.
What is the auto power-off time?
The device automatically turns off after 5 minutes of inactivity to save battery.
Is the CT 5000H waterproof?
It has an IP54 rating, meaning it is splash-proof and dust-resistant, but not waterproof. Do not submerge.
Where can I find the manual?
The user manual is available for free download on notice-facile.com in PDF format.

User questions about CT 5000H PCE Instruments

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Measurement in PDF format for free! Find your manual CT 5000H - PCE Instruments and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. CT 5000H by PCE Instruments.

USER MANUAL CT 5000H PCE Instruments

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : PCE Instruments

Model : CT 5000H

Category : Measurement