DGST-10-10-PA - Uncategorized Festo - Free user manual and instructions
Find the device manual for free DGST-10-10-PA Festo in PDF.
Pick your language and provide your email: we'll send you a specifically translated version.
| Product Type | Guided Pneumatic Cylinder |
| Piston Diameter | 10 mm |
| Stroke Length | 10 mm |
| Operating Pressure | 1 to 10 bar |
| Ambient Temperature Range | 0 to 60 °C |
| Cushioning Type | Elastic cushioning rings at both ends |
| Port Size | M5 |
| Body Material | Aluminum alloy |
| Piston Rod Material | Stainless steel |
| Guide Type | Ball bearing guide |
| Weight | Approx. 50 g |
| Repetition Accuracy | ≤ 0.01 mm |
| Maintenance Requirement | Maintenance-free (dry lubrication) |
| Corrosion Protection | Good |
| Mounting Position | Any |
| Medium | Filtered compressed air (lubricated or unlubricated) |
| Seals Material | NBR (standard) |
| Max. Piston Rod Thread | M4 |
| Guide Accuracy | High precision |
| Energy Supply | Compressed air |
Frequently Asked Questions - DGST-10-10-PA Festo
What is the operating pressure range for the DGST-10-10-PA?
The recommended operating pressure is 1 to 10 bar. Ensure the air supply is filtered to at least 40 μm.
How do I mount the cylinder?
Mount the cylinder in any orientation using the threaded holes in the body and piston rod. Ensure the load is applied centrally to avoid side forces.
Can I use unlubricated air?
Yes, the cylinder is designed for maintenance-free operation with dry lubrication. Both lubricated and unlubricated air are acceptable.
What is the maximum allowable lateral force?
The guided design handles moderate lateral loads, but excessive side forces can reduce life. Refer to the manual for specific limits.
How do I adjust the cushioning?
Cushioning is fixed via elastic rings at both ends; no adjustment is possible. For softer end-of-stroke, reduce speed or pressure.
What maintenance is required?
The cylinder is maintenance-free. Periodically inspect for leaks and cleanliness. Replace seals if necessary (see spare parts).
What is the ambient temperature range?
Operate from 0 to 60 °C. For extreme temperatures, consult Festo for special versions.
How do I replace seals?
Remove the end caps, extract old seals, and install new ones from the seal kit. Use assembly grease to prevent damage.
What are the port sizes?
Port size is M5. Use appropriate fittings and tubing (e.g., 4 mm OD).
What is the weight of the cylinder?
Approximately 50 g, making it suitable for lightweight applications.
User questions about DGST-10-10-PA Festo
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
No questions yet. Be the first to ask one.
Download the instructions for your Uncategorized in PDF format for free! Find your manual DGST-10-10-PA - Festo and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. DGST-10-10-PA by Festo.