Product Type Air-Cooled Chiller
Brand Daikin
Model EWAD800T-SSB2
Cooling Capacity (nominal) 800 kW
Dimensions (H x W x D) 2200 x 2500 x 4500 mm
Weight 3500 kg
Power Supply 400V / 3-phase / 50 Hz
Refrigerant R-410A
Compressor Type Screw compressor
Evaporator Type Shell-and-tube
Condenser Type Air-cooled finned coil
EER (Energy Efficiency Ratio) 3.2
Noise Level 85 dB(A)
Operating Temperature Range -10 to 46 °C
Control System Microprocessor controller with touch screen
Protection Features High/low pressure, freeze, motor overload, phase loss
Maintenance Clean condenser coils annually, check refrigerant charge
Installation Outdoor installation on a level concrete pad
Warranty 2 years parts and labor
Certifications CE, EAC, RoHS

Frequently Asked Questions - EWAD800T-SSB2 DAIKIN

How do I reset the chiller after a fault?
Press the reset button on the control panel after addressing the fault cause. Refer to the manual for specific fault codes.
What refrigerant does the EWAD800T-SSB2 use?
It uses R-410A refrigerant. Always follow proper handling procedures.
How often should the condenser coils be cleaned?
At least once a year. More frequent cleaning may be needed in dusty environments.
What is the recommended clearances around the unit?
Minimum 1.5 m clearance on all sides for proper airflow and maintenance access.
Can the chiller be installed indoors?
No, it is designed for outdoor installation only due to air-cooled condenser requirements.
How do I check the refrigerant charge?
Use a manifold gauge set to measure suction and discharge pressures. Compare with the pressure-temperature chart in the manual.
What does error code 'E1' mean?
E1 indicates high pressure fault. Check condenser fans, coils, and refrigerant charge.
What is the maximum ambient temperature for operation?
The chiller can operate up to 46 °C ambient temperature.
How do I adjust the setpoint temperature?
Use the touch screen controller to navigate to the setpoint menu and adjust the desired leaving water temperature.
Is a specific oil type required for the compressor?
Yes, use only POE oil specified by Daikin for R-410A screw compressors.

User questions about EWAD800T-SSB2 DAIKIN

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Air Conditioning in PDF format for free! Find your manual EWAD800T-SSB2 - DAIKIN and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. EWAD800T-SSB2 by DAIKIN.

USER MANUAL EWAD800T-SSB2 DAIKIN

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : DAIKIN

Model : EWAD800T-SSB2

Category : Air Conditioning