EWAD800T-SSB2 - Air Conditioning DAIKIN - Free user manual and instructions
Find the device manual for free EWAD800T-SSB2 DAIKIN in PDF.
Pick your language and provide your email: we'll send you a specifically translated version.
| Product Type | Air-Cooled Chiller |
| Brand | Daikin |
| Model | EWAD800T-SSB2 |
| Cooling Capacity (nominal) | 800 kW |
| Dimensions (H x W x D) | 2200 x 2500 x 4500 mm |
| Weight | 3500 kg |
| Power Supply | 400V / 3-phase / 50 Hz |
| Refrigerant | R-410A |
| Compressor Type | Screw compressor |
| Evaporator Type | Shell-and-tube |
| Condenser Type | Air-cooled finned coil |
| EER (Energy Efficiency Ratio) | 3.2 |
| Noise Level | 85 dB(A) |
| Operating Temperature Range | -10 to 46 °C |
| Control System | Microprocessor controller with touch screen |
| Protection Features | High/low pressure, freeze, motor overload, phase loss |
| Maintenance | Clean condenser coils annually, check refrigerant charge |
| Installation | Outdoor installation on a level concrete pad |
| Warranty | 2 years parts and labor |
| Certifications | CE, EAC, RoHS |
Frequently Asked Questions - EWAD800T-SSB2 DAIKIN
How do I reset the chiller after a fault?
Press the reset button on the control panel after addressing the fault cause. Refer to the manual for specific fault codes.
What refrigerant does the EWAD800T-SSB2 use?
It uses R-410A refrigerant. Always follow proper handling procedures.
How often should the condenser coils be cleaned?
At least once a year. More frequent cleaning may be needed in dusty environments.
What is the recommended clearances around the unit?
Minimum 1.5 m clearance on all sides for proper airflow and maintenance access.
Can the chiller be installed indoors?
No, it is designed for outdoor installation only due to air-cooled condenser requirements.
How do I check the refrigerant charge?
Use a manifold gauge set to measure suction and discharge pressures. Compare with the pressure-temperature chart in the manual.
What does error code 'E1' mean?
E1 indicates high pressure fault. Check condenser fans, coils, and refrigerant charge.
What is the maximum ambient temperature for operation?
The chiller can operate up to 46 °C ambient temperature.
How do I adjust the setpoint temperature?
Use the touch screen controller to navigate to the setpoint menu and adjust the desired leaving water temperature.
Is a specific oil type required for the compressor?
Yes, use only POE oil specified by Daikin for R-410A screw compressors.
User questions about EWAD800T-SSB2 DAIKIN
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
No questions yet. Be the first to ask one.