RMC58S6 - Refrigerator Traulsen - Free user manual and instructions
Find the device manual for free RMC58S6 Traulsen in PDF.
Pick your language and provide your email: we'll send you a specifically translated version.
| Product Type | Commercial Refrigerator |
| Model | RMC58S6 |
| Brand | Traulsen |
| Dimensions (W x D x H) | 48" x 31" x 83" |
| Weight | 400 lbs |
| Power Supply | 115 V / 60 Hz, 1 phase, 15 A |
| Temperature Range | 33°F to 38°F (0.5°C to 3.3°C) |
| Capacity | 58 cu. ft. (approx.) |
| Number of Doors | 6 |
| Door Type | Self-closing, stay-open feature |
| Interior Material | Stainless steel |
| Exterior Material | Stainless steel |
| Cooling System | Forced air circulation |
| Refrigerant | R-404A or R-290 (check label) |
| Temperature Control | Digital electronic control with thermostat |
| Display | LED temperature display |
| Alarms | High/low temperature alarm, door open alarm |
| Defrost | Automatic, time or demand defrost |
| Shelving | Adjustable, chrome-plated wire or stainless steel |
| Castors | Heavy-duty, front locking |
| Certifications | NSF, UL, ETL, DOE 2017 compliant |
| Cleaning | Clean condenser coils monthly; gaskets with mild soap |
| Repairability | Replacement parts available through certified service |
Frequently Asked Questions - RMC58S6 Traulsen
How do I set the temperature on my Traulsen RMC58S6?
Press the SET button on the digital controller, use the up/down arrows to adjust to desired temperature between 33°F and 38°F. Press ENTER to confirm.
What should I do if the temperature alarm sounds?
Check if the door is fully closed and ensure the condenser coils are clean. If the alarm persists, verify the temperature setpoint and call a qualified technician.
How often should I clean the condenser coils?
Clean the coils at least monthly using a soft brush or vacuum. Dirty coils cause poor cooling and higher energy consumption.
Can I adjust the door swing?
The self-closing doors are factory-set. Adjustment of the closing force is done via a tension screw on the hinge. Consult the manual or a technician for details.
What type of refrigerant does the RMC58S6 use?
It uses R-404A or newer models may use R-290 (propane). Check the serial plate on the back of the unit.
How do I replace an interior light bulb?
Disconnect power. Remove the light cover by sliding or pressing the clips. Replace with a compatible LED or incandescent bulb (max 40W). Reattach cover.
Why is my refrigerator not cooling properly?
Common causes: dirty condenser coils, blocked air vents, improper door seal, or thermostat set too high. Perform a thorough check and clean as needed.
What are the electrical requirements?
Requires a 115 V, 60 Hz, 15 A dedicated circuit with a grounded outlet. Do not use extension cords.
How do I level the refrigerator?
Turn the adjustable feet or castors at the bottom until the unit is level front-to-back and side-to-side. Use a bubble level placed on top of the cabinet.
Where can I find replacement parts?
Contact an authorized Traulsen distributor or visit the Traulsen Parts website. Provide the model RMC58S6 and serial number.
User questions about RMC58S6 Traulsen
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
No questions yet. Be the first to ask one.
Download the instructions for your Refrigerator in PDF format for free! Find your manual RMC58S6 - Traulsen and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. RMC58S6 by Traulsen.