PC-40LT - Scale Tor Rey - Free user manual and instructions
Find the device manual for free PC-40LT Tor Rey in PDF.
Pick your language and provide your email: we'll send you a specifically translated version.
| Brand | Tor Rey |
| Model | PC-40LT |
| Type | Digital Postal Scale |
| Weighing Capacity | 40 kg (88 lb) |
| Readability | 5 g (0.01 lb) |
| Display | LCD with backlight |
| Units | kg, lb, oz, g |
| Functions | Tare, Hold, Auto-Off, Zero, Counting |
| Platform Size | 320 x 240 mm (12.6 x 9.4 in) |
| Dimensions (W x D x H) | 350 x 280 x 80 mm |
| Net Weight | 2.5 kg (5.5 lb) |
| Power Supply | 6 x AA batteries (included) or AC adapter (optional) |
| Battery Life | Approx. 200 hours of use |
| Material | ABS plastic platform, stainless steel metal parts |
| Overload Protection | Yes, automatic shutdown at >40.5 kg |
| Low Battery Indicator | Yes, symbol on display |
| Calibration | Automatic with external weights (user manual) |
| Operating Temperature | 0°C to 40°C (32°F to 104°F) |
| Storage Temperature | -10°C to 60°C (14°F to 140°F) |
| Warranty | 1 year limited |
Frequently Asked Questions - PC-40LT Tor Rey
How do I turn on the scale?
Press the ON/OFF button. If the scale does not turn on, check that the batteries are installed correctly and have sufficient power.
How to use the tare function?
Place the empty container on the scale, then press the TARE button. The display will reset to zero. Add the item to be weighed; the display will show only the net weight.
What does the Hold function do?
The HOLD function locks the weight reading on the display after about 3 seconds of stable weight, making it easier to read when weighing items in an awkward position.
How do I change the weighing unit?
Press the UNIT button repeatedly to cycle through kg, lb, oz, and g. The selected unit will be shown on the display.
Why does the scale shut off automatically?
The scale has an auto-off feature to conserve battery life. It will turn off after about 2 minutes of inactivity. To disable this feature (if you need continuous weighing), press and hold the ON/OFF button for 3 seconds until 'AOFF' disappears from the display.
How to calibrate the scale?
Ensure the scale is on a level surface and turned on. Press and hold the ON/OFF button until 'CAL' appears. Follow the prompts: place the specified calibration weight (usually 20 kg) on the platform when requested. The scale will auto-calibrate and return to weighing mode.
What kind of batteries does the scale require?
The scale uses 6 x AA batteries (alkaline recommended). Insert them with correct polarity as indicated inside the battery compartment. You can also use an optional AC adapter (DC 9V, center positive) plugged into the DC jack.
How to clean the scale?
Turn off the scale and remove batteries. Wipe the platform and housing with a soft, damp cloth. Do not use abrasive cleaners or immerse in water. Dry thoroughly before use.
What is the maximum weight I can weigh?
The maximum capacity is 40 kg (88 lb). Exceeding this by more than 0.5 kg may cause the scale to display 'O-Ld' and could damage the sensor. Remove the weight immediately.
The display shows 'Err' or 'EEEE'. What should I do?
This indicates an overload or internal error. Remove the weight immediately. If the error persists, recalibrate the scale (see calibration question) or check for any foreign objects under the platform. If still not working, contact Tor Rey support.