APDU1335TH - Inverter APC - Free user manual and instructions
Find the device manual for free APDU1335TH APC in PDF.
Pick your language and provide your email: we'll send you a specifically translated version.
| Product Type | Uninterruptible Power Supply (UPS) |
| Topology | Line Interactive |
| Power Rating | 1500 VA / 1350 W |
| Input Voltage | 230 V AC |
| Output Voltage | 230 V AC ± 5% |
| Number of Outlets | 8 (6 battery backup + 2 surge-only) |
| Battery Type | Sealed Lead-Acid, maintenance-free |
| Typical Backup Time at Half Load | 15 minutes |
| Recharge Time | 4 hours to 90% |
| Dimensions (H x W x D) | 2U: 89 x 445 x 460 mm |
| Weight | 25.5 kg |
| Operating Temperature | 0 to 40 °C |
| Relative Humidity | 0 to 95% non-condensing |
| Noise Level | < 45 dBA at 1 m |
| Communication Ports | USB, RS-232, SmartSlot |
| Management Software | APC PowerChute |
| Surge Protection | 320 joules |
| Safety Certifications | CE, TUV, VDE |
| Replacement Battery Cartridge | RBC55 |
| Warranty | 3 years (electronics), 2 years (battery) |
Frequently Asked Questions - APDU1335TH APC
What is the typical backup time for the APDU1335TH?
At half load (675 W), you can expect approximately 15 minutes of backup time. Full load (1350 W) reduces runtime to around 5 minutes.
How do I replace the battery?
The battery is hot-swappable – simply open the front panel, disconnect the old battery, and insert the new RBC55 cartridge. No power-down required.
Can I connect the UPS to a network?
Yes. The SmartSlot can accept an optional network management card (e.g., AP9630) for remote monitoring and control via SNMP.
What type of outlets does it have?
It has 8 IEC C13 outlets: 6 provide battery backup and surge protection, while 2 offer surge-only protection.
How loud is the UPS during operation?
Under normal load, the fan noise is less than 45 dBA – barely audible in a standard office environment.
What is the input voltage range?
The UPS accepts input voltage from 160 V to 275 V AC without switching to battery, thanks to Automatic Voltage Regulation (AVR).
Does the UPS protect against surges?
Yes, it provides 320 joule surge protection and also filters electromagnetic interference.
How long does the battery take to recharge?
After a full discharge, the battery recharges to 90% in approximately 4 hours.
What software is available for management?
APC PowerChute Personal Edition (Windows/Mac) provides graceful shutdown and monitoring. For advanced features, use PowerChute Network Shutdown.
Is the UPS rackmount compatible?
Yes, it is designed for 2U racks with included mounting rails. It can also be used as a tower.
User questions about APDU1335TH APC
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
No questions yet. Be the first to ask one.
Download the instructions for your Inverter in PDF format for free! Find your manual APDU1335TH - APC and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. APDU1335TH by APC.