AS 1000-IN E - Boiler Baxi - Free user manual and instructions
Find the device manual for free AS 1000-IN E Baxi in PDF.
Pick your language and provide your email: we'll send you a specifically translated version.
| Brand | Baxi |
| Model | AS 1000-IN E |
| Product Type | Gas Boiler |
| Dimensions (HxWxD) | 800 x 450 x 350 mm |
| Weight | 35 kg |
| Power Input | 24 kW |
| Power Output (Heating) | 24 kW |
| Power Output (DHW) | 28 kW |
| Efficiency | Up to 94% |
| Energy Class | C |
| Fuel | Natural Gas / LPG |
| Water Connection | 15 mm |
| Gas Connection | 15 mm |
| Flue Type | Room sealed / Balanced flue |
| Ignition | Electronic |
| Control | Digital display with thermostat |
| Functions | Central heating and domestic hot water |
| Heat Exchanger | Stainless steel |
| Pump | Integrated variable speed pump |
| Expansion Vessel | 8 liters |
| Noise Level | < 50 dB(A) |
| Electrical Supply | 230V / 50Hz |
| Protection | IPX4 |
| Maintenance | Annual service recommended |
| Safety | Overheat protection, frost protection, safety valve, pressure switch |
| Spare Parts | Available through Baxi distributors |
Frequently Asked Questions - AS 1000-IN E Baxi
What is the recommended water pressure for the Baxi AS 1000-IN E boiler?
The recommended water pressure is between 1.0 and 1.5 bar when the system is cold. If the pressure drops below 0.5 bar, you may need to repressurize the system using the filling loop.
How do I reset the boiler after a fault?
To reset the boiler, press and hold the reset button on the control panel for 3 seconds. If the fault persists, check the error code on the display and consult the manual.
What does error code E01 mean?
Error code E01 typically indicates a flame loss or ignition failure. Check the gas supply, spark electrode, and ensure the flue is not blocked. If the problem continues, contact a qualified technician.
How often should I service the boiler?
It is recommended to service the boiler annually by a Gas Safe registered engineer to ensure efficient and safe operation.
Can the boiler be used with a new heating system?
Yes, the Baxi AS 1000-IN E is compatible with most modern heating systems. However, ensure the system is flushed and cleaned before installation to prevent debris damage.
What is the maximum flow temperature?
The maximum flow temperature is 82°C for central heating and 65°C for domestic hot water (depending on settings). Adjust via the control panel.
How do I adjust the heating temperature?
Use the heating temperature knob or digital menu on the control panel to set the desired flow temperature between 30°C and 82°C.
Why is the boiler making a banging noise?
Banging noises may be caused by air in the system or kettling due to limescale buildup. Bleed the radiators and consider descaling if needed.
Is the boiler compatible with smart thermostats?
Yes, the boiler is compatible with most smart thermostats that use standard OpenTherm or on/off control. Consult the manual for wiring details.
What type of flue is required?
The boiler uses a room-sealed balanced flue (concentric pipe). Ensure the flue is installed horizontally or vertically within the specified length limits (e.g., max 5m).