CyberPower

CPS160PBURC1 - Battery CyberPower - Free user manual and instructions

Find the device manual for free CPS160PBURC1 CyberPower in PDF.

📄 1 pages English EN Download 💬 AI Question 10 questions ⚙️ Specs
Notice CyberPower CPS160PBURC1 - page 1
Pick your language and provide your email: we'll send you a specifically translated version.
Product Type UPS Replacement Battery
Brand CyberPower
Model CPS160PBURC1
Voltage 12V
Capacity 7.2 Ah
Chemistry Sealed Lead-Acid (SLA)
Terminal Type F1 (0.187" Faston Tab)
Dimensions (L x W x H) 4.5 x 3.5 x 6.5 inches
Weight 4.9 lbs
Compatible UPS Models CyberPower CP850, CP1000, CP1100, CP1350, CP1500, etc.
Charge Voltage 13.7 - 14.1V (float), 14.4 - 15.0V (cycle)
Operating Temperature 32°F to 104°F (0°C to 40°C)
Maintenance Maintenance-free, no electrolyte refill needed
Safety Features VRLA (Valve Regulated), spill-proof, explosion-proof
Replacement Frequency Every 3-5 years under normal use
Disposal Recycle per local regulations; contains lead acid

Frequently Asked Questions - CPS160PBURC1 CyberPower

How do I replace the battery in my CyberPower UPS with the CPS160PBURC1?
First, unplug the UPS and disconnect all devices. Open the battery compartment, disconnect the old battery terminals (red to positive, black to negative), remove the old battery, insert the new CPS160PBURC1, reconnect terminals, and close the compartment. Dispose of the old battery properly.
What is the expected lifespan of the CPS160PBURC1 battery?
Under normal operating conditions (room temperature, light load), the battery lasts 3 to 5 years. Higher temperatures or frequent deep discharges can shorten its life.
Can I use the CPS160PBURC1 in any CyberPower UPS?
No, it is compatible with specific CyberPower models that require a 12V 7.2Ah battery with F1 terminals. Check your UPS manual or our compatibility list to ensure fit.
How do I charge the CPS160PBURC1?
The UPS charges the battery automatically when plugged in. No external charger is needed. For best performance, keep the UPS plugged in continuously.
What are the storage recommendations for the CPS160PBURC1?
Store in a cool, dry place between 32°F and 77°F (0°C to 25°C). Recharge every 6 months to prevent sulphation. Do not store fully discharged.
Is the CPS160PBURC1 battery maintenance-free?
Yes, it is sealed and maintenance-free. You do not need to add water or check electrolyte levels. Simply install and use.
What does the 'VRLA' label mean on the battery?
VRLA stands for Valve Regulated Lead-Acid. It means the battery is sealed, with a safety valve to release excess pressure. It is spill-proof and can be used in any orientation except upside down.
How do I properly dispose of a used CPS160PBURC1?
Recycle at a designated battery recycling center or follow local hazardous waste regulations. Do not throw in regular trash as it contains lead and sulfuric acid.
Why is my UPS beeping after replacing with a new CPS160PBURC1?
The UPS may beep if the battery is not fully charged or if connections are loose. Allow 24 hours for the battery to charge. If beeping persists, check terminal connections.
What is the warranty on the CPS160PBURC1 battery?
CyberPower typically offers a 1-year warranty for replacement batteries. Check your purchase receipt or contact support for specific details.

User questions about CPS160PBURC1 CyberPower

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Battery in PDF format for free! Find your manual CPS160PBURC1 - CyberPower and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. CPS160PBURC1 by CyberPower.

USER MANUAL CPS160PBURC1 CyberPower

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : CyberPower

Model : CPS160PBURC1

Category : Battery