2118-2 - Measurement Daytronic - Free user manual and instructions
Find the device manual for free 2118-2 Daytronic in PDF.
Pick your language and provide your email: we'll send you a specifically translated version.
| Product Type | Signal Conditioner / Measurement Module |
| Dimensions (H x W x D) | 8.5 x 2.5 x 6 in (216 x 64 x 152 mm) |
| Weight | 1.5 lbs (0.68 kg) |
| Power Supply | 115/230 V AC, 50-60 Hz, 10 VA |
| Measurement Functions | Voltage, current, temperature (thermocouple, RTD), frequency |
| Input Channels | 2 differential inputs |
| Output Signal | 0-10 V DC or 4-20 mA (selectable) |
| Accuracy | ±0.1% of reading + 0.05% of range |
| Operating Temperature | 0°C to 60°C |
| Storage Temperature | -20°C to 85°C |
| Humidity Range | 0 to 90% non-condensing |
| Housing Material | Aluminum with protective coating |
| Mounting | Panel mount or DIN rail |
| Maintenance | Clean with dry cloth; no internal adjustments required |
| Safety Features | Overvoltage protection, galvanic isolation (1500 V rms) |
| EMC Compliance | EN 61326-1 (industrial environment) |
| Spare Parts | Replacement connectors and fuses available from Daytronic |
| Repairability | Module can be returned to Daytronic for repair |
| Warranty | 1 year from date of purchase |
Frequently Asked Questions - 2118-2 Daytronic
How do I connect the Daytronic 2118-2 to a sensor?
Connect the sensor wires to the input terminals according to the wiring diagram in the manual. Ensure correct polarity for voltage or current signals. For thermocouples, use the appropriate extension wire.
What power supply is required for the 2118-2?
The 2118-2 accepts 115 or 230 V AC, 50-60 Hz. Refer to the voltage selector switch on the side of the unit. Power consumption is less than 10 VA.
How can I change the output range from 0-10V to 4-20mA?
Locate the output jumpers inside the module. Set them to the desired output type. Refer to the manual for jumper positions. After changing, recalibrate if necessary.
What is the calibration interval for the 2118-2?
Daytronic recommends annual calibration to maintain specified accuracy. Calibration can be performed by an accredited lab or returned to Daytronic.
Can I use the 2118-2 with a PT100 RTD?
Yes, the 2118-2 supports PT100 RTDs in 2-wire, 3-wire, or 4-wire configurations. Select the appropriate input range and connect accordingly.
The output reading is unstable. What should I check?
Check for loose connections, electrical noise from nearby equipment, or improper grounding. Ensure the input signal is within range and the sensor is properly shielded. If problem persists, contact Daytronic support.
How do I mount the 2118-2 on a DIN rail?
Attach the DIN rail mounting bracket (included) to the back of the module. Snap the module onto a standard 35 mm DIN rail. For panel mount, use the screws provided.
Is the 2118-2 suitable for outdoor use?
The 2118-2 is designed for indoor use only. It should be installed in a dry, sheltered environment with ambient temperature between 0°C and 60°C. Avoid direct sunlight and moisture.
What is the maximum wire length for inputs?
For voltage inputs, keep wire length under 100 meters to minimize noise. For 4-20 mA loops, up to 1000 meters is possible. For thermocouples, use appropriate extension wire and limit to 50 meters.
Where can I find the user manual for the 2118-2?
The user manual is available for free download on notice-facile.com. Select your language and provide your email to receive a translated version.
User questions about 2118-2 Daytronic
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
No questions yet. Be the first to ask one.
Download the instructions for your Measurement in PDF format for free! Find your manual 2118-2 - Daytronic and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. 2118-2 by Daytronic.