| Product Type | PC/104 Serial Communication Module |
| Model | PCM-3618 |
| Brand | Advantech |
| Serial Ports | 4 ports (RS-232/422/485 selectable per port) |
| Bus Interface | PC/104 (ISA) 16-bit |
| Dimensions | 90 mm x 96 mm (PC/104 standard) |
| Weight | Approx. 100 g |
| Power Consumption | 5V DC, typical 400 mA (max 500 mA) |
| Operating Temperature | 0°C to 60°C (32°F to 140°F) |
| Data Rate | Up to 115.2 kbps per port |
| Connector Type | 2x 20-pin box header (IDC) for serial signals |
| Isolation | 2500V DC isolation on RS-232/422/485 |
| ESD Protection | 15 kV air, 8 kV contact |
| Compatible Operating Systems | Windows, Linux, QNX, DOS |
| Mounting | Stackable PC/104 modules |
| Maintenance | Keep free of dust; no user-serviceable parts |
| Safety Compliance | CE, FCC Class A |
| Spare Parts | Contact Advantech for replacement or repair |
| Repairability | Not field-repairable; send to manufacturer |
Frequently Asked Questions - PCM-3618 Advantech
What is the PCM-3618?
The Advantech PCM-3618 is a PC/104 serial communication module that provides four independently configurable RS-232/422/485 serial ports.
Does the PCM-3618 require an external power supply?
No, it is powered directly from the PC/104 bus at 5V DC.
How do I configure the serial ports?
Each port can be set to RS-232, RS-422, or RS-485 via DIP switches or jumper blocks on the module.
What is the maximum data rate supported?
Each port supports data rates up to 115.2 kbps.
Can I use this module with Linux?
Yes, drivers are available for Linux, Windows, QNX, and DOS.
How do I install the PCM-3618?
Simply stack it onto a PC/104 CPU board using the bus connectors and secure with standoffs.
What kind of connector does it use for serial cables?
It uses a 20-pin IDC box header; a cable is typically required to connect to DB9 or DB25 connectors.
Is the PCM-3618 isolated?
Yes, it provides 2500V DC isolation on the serial signals for industrial environments.
How do I troubleshoot if a port is not working?
Check the I/O address and IRQ settings via DIP switches, ensure drivers are installed, and verify cable wiring.
Can I replace the PCM-3618 myself if it fails?
The module is not field-repairable. Contact Advantech support for RMA and replacement.