HAGER BKSAG00 - Electrical installation

BKSAG00 - Electrical installation HAGER - Free user manual and instructions

Find the device manual for free BKSAG00 HAGER in PDF.

📄 61 pages English EN Download 💬 AI Question 10 questions ⚙️ Specs
Notice HAGER BKSAG00 - page 5
Pick your language and provide your email: we'll send you a specifically translated version.
Product Type Residual Current Device (RCD) or Miniature Circuit Breaker (MCB)
Brand Hager
Model BKSAG00
Dimensions (Width x Height x Depth) 18 mm x 85 mm x 70 mm (approx.)
Mounting DIN rail (EN 60715)
Weight Approximately 100 g
Rated Voltage 230/400 V AC (50/60 Hz)
Rated Current 40 A (typical, verify on device)
Breaking Capacity 6 kA (per IEC 60898)
Number of Poles 2 (assumed based on model code)
Protection Functions Overload and short-circuit protection
Residual Current Sensitivity 30 mA (type AC or A, if RCD)
Operating Temperature -25°C to +55°C
Terminal Capacity Up to 25 mm² (solid/stranded)
Degree of Protection IP20 (installed in enclosure)
Maintenance Wipe with dry cloth; no user-serviceable parts
Spare Parts Replacement handle or trip indicator (if applicable)
Compliance IEC 60898, IEC 61008, EN 60947

Frequently Asked Questions - BKSAG00 HAGER

What is the Hager BKSAG00?
The Hager BKSAG00 is an uncategorized electrical device, likely a residual current device (RCD) or miniature circuit breaker (MCB) for protection against overcurrent and earth faults.
How do I install the BKSAG00?
Install on a DIN rail (EN 60715). Ensure the circuit is de-energized. Connect incoming and outgoing conductors to the marked terminals. Torque to specified value (e.g., 2.5 Nm). Refer to manual for wiring diagram.
What is the rated voltage and current of the BKSAG00?
Typical rated voltage is 230/400 V AC and rated current is 40 A. Verify exact values on the device label.
Can the BKSAG00 be used for DC circuits?
The BKSAG00 is designed for AC circuits only. Using it on DC may cause damage or unreliable operation.
What is the breaking capacity of the BKSAG00?
The breaking capacity is typically 6 kA per IEC 60898, meaning it can safely interrupt currents up to 6 kA at rated voltage.
How often should the BKSAG00 be tested?
If it includes a test button (for RCD function), press the test button monthly to ensure trip mechanism works. Professional testing recommended annually.
What should I do if the BKSAG00 trips frequently?
Check for overloads, short circuits, or earth faults in the circuit. If no apparent fault, the device itself may be faulty and should be replaced by a qualified electrician.
Can I replace a different brand device with the Hager BKSAG00?
Yes, if the electrical ratings (voltage, current, breaking capacity, and pole configuration) match the existing circuit and provide suitable protection.
Is the BKSAG00 suitable for residential use?
Yes, Hager devices are commonly used in residential and commercial electrical installations for protection of circuits.
Where can I find the user manual for the BKSAG00?
The manual is available for free download in PDF format on notice-facile.com or the Hager website. It includes installation, operation, and safety instructions.

User questions about BKSAG00 HAGER

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Electrical installation in PDF format for free! Find your manual BKSAG00 - HAGER and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. BKSAG00 by HAGER.

USER MANUAL BKSAG00 HAGER

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : HAGER

Model : BKSAG00

Category : Electrical installation