| Product Type | Distribution Board |
| Brand | Hager |
| Model | BKFD600045 |
| Dimensions (H x W x D) | 300 mm x 400 mm x 120 mm |
| Weight | 2.5 kg |
| Material | Metal with plastic cover |
| IP Rating | IP30 |
| Number of Ways | 12 |
| Rated Current | 100 A |
| Rated Voltage | 230/400 V AC |
| Frequency | 50 Hz |
| Main Functions | Distribution of electrical circuits, overload and short-circuit protection |
| Mounting Type | Wall-mounted |
| Operating Temperature | -5°C to +40°C |
| Maintenance | Periodic inspection of connections and cleanliness |
| Safety Features | IP30 protection, insulated barriers, earthing terminal |
| Spare Parts Availability | Through authorized Hager distributors |
| Compliance Standards | EN 60439, IEC 61439 |
| Warranty | 2 years |
Frequently Asked Questions - BKFD600045 HAGER
What tools are needed for installation?
You will need a screwdriver, cable cutters, and a voltage tester. Ensure the main power is off before starting.
How do I connect the incoming supply cable?
Connect the phase, neutral, and earth cables to the corresponding busbars. Torque to the recommended value (typically 2.5 Nm).
What is the maximum cable size for terminals?
The terminals accept cables up to 25 mm² for phase and neutral, and 16 mm² for earth.
Can I use this board outdoors?
The IP30 rating means it is not suitable for outdoor use unless placed in a weatherproof enclosure.
How do I replace a circuit breaker?
Isolate the supply, remove the cover, unscrew the faulty breaker, disconnect wires, and install a new one with the same rating.
What is the recommended tightness for screws?
For terminals, use a torque of 2.5 Nm; for cover screws, 1.2 Nm.
Is this board compatible with RCBOs?
Yes, it accepts Hager RCBOs of the same brand and series.
How often should I inspect the board?
Inspect annually for signs of overheating, corrosion, or loose connections.
What should I do if the main switch trips frequently?
Check for overloading or a short circuit. If unresolved, consult a qualified electrician.
Where can I find the wiring diagram?
The wiring diagram is inside the cover door. Additional copies can be downloaded from Hager's website.