IPCP Pro 250 xi - Uncategorized Extron - Free user manual and instructions
Find the device manual for free IPCP Pro 250 xi Extron in PDF.
Pick your language and provide your email: we'll send you a specifically translated version.
| Product Type | Control Processor with IP Link Pro |
| Dimensions (H x W x D) | 1.7" x 6.7" x 3.0" (4.3 cm x 17.0 cm x 7.6 cm) |
| Weight | 1.0 lb (0.45 kg) |
| Power Supply | 12 VDC, 0.5 A (external power supply included) |
| Power over Ethernet (PoE) | Yes, IEEE 802.3af (PoE Class 0) |
| Ethernet Ports | 2 RJ-45 (1 LAN, 1 LAN/AV LAN) with built-in 2-port switch |
| Serial Ports | 2 RS-232 (3.5 mm captive screw connectors) |
| IR Control | 2 IR emitters (3.5 mm mini stereo jacks) |
| Relay Ports | 2 relay ports (3.5 mm captive screw, 1 A @ 24 VAC/VDC) |
| Digital I/O | 2 digital I/O ports (configurable) |
| Processor | Real-time control processor with 32-bit ARM architecture |
| Software Control | Extron Global Configurator Professional, Global Scripter |
| Web Interface | Built-in web server for configuration and monitoring |
| Mounting | Half rack width, rack mountable (bracket included) |
| Cleaning Instructions | Wipe with a soft, dry cloth. Do not use liquid cleaners. |
| Safety Precautions | Use only included power supply; ensure ventilation; avoid moisture. |
| Repairability | No user-serviceable parts. Contact Extron support for repairs. |
| Warranty | 3 years parts and labor |
| Environmental Temperature | 32 to 122°F (0 to 50°C) |
| Environmental Humidity | 10% to 90% noncondensing |
Frequently Asked Questions - IPCP Pro 250 xi Extron
How do I access the web interface of the IPCP Pro 250 xi?
Connect the device to your network via the LAN port. Use a web browser and enter the default IP address (192.168.254.254) or use Extron's Global Configurator to discover the IP.
Can I power the IPCP Pro 250 xi through PoE?
Yes, it supports Power over Ethernet (IEEE 802.3af Class 0). Ensure your PoE switch provides enough power.
How do I reset the unit to factory defaults?
Press and hold the rear panel Reset button for 5 seconds until the front panel LEDs flash. Release to reset.
What software is needed to program the IPCP Pro 250 xi?
Use Extron Global Configurator Professional or Global Scripter for programming. Both are available for free from the Extron website.
How many RS-232 devices can I control?
The unit has two RS-232 ports, each capable of controlling one device. You can also extend control via IP or IR.
What is the default IP address?
The default static IP is 192.168.254.254 with subnet mask 255.255.0.0. The default username and password are admin.
Does the IPCP Pro 250 xi support IR learning?
No, it does not support IR learning. It uses pre-configured IR drivers from Extron's IR library.
How can I update the firmware?
Download the latest firmware from Extron's support site. Upload via the web interface under 'Maintenance > Firmware Update'.
What is the maximum cable length for RS-232?
The maximum recommended RS-232 cable length is 50 feet (15 meters) at 9600 baud.
Can I use the unit as a network switch?
It has a 2-port Ethernet switch for connecting a control device and an AV device, but it is not a full network switch.
User questions about IPCP Pro 250 xi Extron
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
No questions yet. Be the first to ask one.
Download the instructions for your Uncategorized in PDF format for free! Find your manual IPCP Pro 250 xi - Extron and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. IPCP Pro 250 xi by Extron.