OCM 166 - Microscope Kern - Free user manual and instructions
Find the device manual for free OCM 166 Kern in PDF.
Pick your language and provide your email: we'll send you a specifically translated version.
| Product Type | Microscope |
| Brand | Kern |
| Model | OCM 166 |
| Magnification Range | 40x - 1000x |
| Eyepiece | WF 10x/20mm |
| Objectives | 4x, 10x, 40x, 100x (oil) |
| Illumination | LED, adjustable brightness |
| Power Supply | 100-240V AC, 50/60Hz |
| Stage | Double-layer mechanical stage, 140x135mm |
| Focus System | Coaxial coarse and fine adjustment |
| Condenser | Abbe NA 1.25 with iris diaphragm |
| Dimensions (WxDxH) | 200 x 300 x 400 mm |
| Net Weight | 5.5 kg |
| Maintenance | Clean lenses with lens paper; store in dry place |
| Safety Precautions | Do not look directly at light source; unplug before cleaning |
| Spare Parts | Available from Kern service centers |
| Repairability | Modular design for easy repair |
| General Information | Manual available in PDF on notice-facile.com |
Frequently Asked Questions - OCM 166 Kern
How do I turn on the Kern OCM 166 microscope?
Connect the power cord to the microscope and plug it into a mains outlet. Turn the power switch located on the side of the base to the 'ON' position. Adjust the brightness with the dimmer knob.
What is the total magnification range?
The total magnification is the eyepiece power (10x) multiplied by the objective power. With objectives 4x, 10x, 40x, and 100x, the range is 40x to 1000x.
How do I change the objective?
Rotate the revolving nosepiece until the desired objective clicks into place. Always start with the lowest magnification for initial focusing.
How do I clean the lenses?
Use a soft lens brush to remove dust, then gently wipe with lens cleaning paper or a microfiber cloth. For stubborn dirt, moisten with isopropyl alcohol or a dedicated lens cleaner. Do not use paper towels.
The light is not turning on. What should I check?
First, ensure the power cord is securely connected. Check the power switch is on. If still off, the bulb may need replacement. Refer to the manual for bulb type and replacement instructions.
How do I use oil immersion for 100x magnification?
Focus with the 40x objective, then rotate the nosepiece halfway toward the 100x objective. Place a drop of immersion oil on the slide. Rotate the 100x objective into place and fine-focus. Clean the objective after use.
What is the function of the iris diaphragm?
The iris diaphragm controls the amount of light passing through the condenser. Adjust it to optimize contrast and resolution for different specimen types.
How do I adjust the interpupillary distance?
While looking through the eyepieces, hold the two eyepiece tubes and slide them closer or farther apart until you see a single circular field of view.
Can I use the microscope with a camera?
Yes, the OCM 166 has a trinocular port (optional) that allows mounting a camera. Alternatively, you can use a smartphone adapter over the eyepiece. Check the manual for compatible accessories.
Where can I find the user manual?
The official manual is available for free download on notice-facile.com in PDF format. You can also find translated versions by requesting via email.
User questions about OCM 166 Kern
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
No questions yet. Be the first to ask one.