Advantech ADAM-5000/TCP - Programmable Logic Controller

ADAM-5000/TCP - Programmable Logic Controller Advantech - Free user manual and instructions

Find the device manual for free ADAM-5000/TCP Advantech in PDF.

📄 222 pages English EN Download 💬 AI Question 10 questions ⚙️ Specs
Notice Advantech ADAM-5000/TCP - page 1
Pick your language and provide your email: we'll send you a specifically translated version.
Product TypeRemote Data Acquisition and Control Module
ModelADAM-5000/TCP
BrandAdvantech
Dimensions (W x H x D)230 mm x 110 mm x 75 mm
WeightApprox. 0.6 kg
Power Supply10 to 30 V DC
Power Consumption2.5 W typical
Communication InterfaceEthernet (TCP/IP), 10/100 Base-T
Supported ProtocolsModbus/TCP, TCP/IP, UDP
Analog Input ChannelsUp to 8 differential or 16 single-ended
Digital I/O ChannelsUp to 16 digital input and 16 digital output
Analog Input Resolution16-bit
Sampling RateUp to 10 kHz per channel
Operating Temperature-10°C to 70°C
Storage Temperature-20°C to 85°C
Humidity5% to 95% non-condensing
ProtectionESD protection, overvoltage protection
MountingDIN rail mountable
MaintenanceClean with a dry, soft cloth; avoid solvents
Spare PartsAvailable via Advantech distributors
RepairabilityModule replacement recommended; no user-serviceable parts

Frequently Asked Questions - ADAM-5000/TCP Advantech

How do I configure the IP address of the ADAM-5000/TCP?
Use the ADAM-5000 Utility software or a web browser to set the IP address. Default IP is 192.168.1.1. Connect via Ethernet and run the utility to assign a new static IP.
What protocols does the ADAM-5000/TCP support?
It supports Modbus/TCP, TCP/IP, and UDP. It can also communicate with Advantech's proprietary protocol for seamless integration.
How many analog inputs can I connect?
Up to 8 differential or 16 single-ended analog input channels, depending on wiring configuration.
Can the ADAM-5000/TCP be used in harsh environments?
Yes, it operates from -10°C to 70°C and has ESD protection. Suitable for industrial environments.
What power supply is required?
A 10 to 30 V DC power supply is required. Typical power consumption is about 2.5 W.
Is the ADAM-5000/TCP compatible with older ADAM modules?
Yes, it is backward compatible with ADAM-4000 and ADAM-5000 series modules using the same I/O expansion bus.
How do I factory reset the module?
Press and hold the Reset button (located on the front panel) for 5 seconds while powering on. This restores default IP settings.
Can I use the ADAM-5000/TCP with a PLC?
Yes, it supports Modbus/TCP, making it easy to integrate with most PLCs and SCADA systems.
What is the maximum cable length for analog inputs?
For accurate measurements, keep analog input cables below 100 meters. Shielded twisted-pair cable is recommended.
Where can I find the user manual?
The user manual is available for free download on notice-facile.com or the Advantech support site. It contains detailed wiring and configuration instructions.

User questions about ADAM-5000/TCP Advantech

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.