Back-UPS Pro BN1350M2 - Alimentation sans coupure APC - Free user manual and instructions
Find the device manual for free Back-UPS Pro BN1350M2 APC in PDF.
Pick your language and provide your email: we'll send you a specifically translated version.
| Product Type | Uninterruptible Power Supply (UPS) |
| Model | Back-UPS Pro BN1350M2 |
| Brand | APC by Schneider Electric |
| VA Rating | 1350 VA |
| Watts Rating | 810 W |
| Input Voltage | 120 VAC (nominal) |
| Output Voltage | 120 VAC (nominal), sine wave |
| Battery Type | Sealed lead-acid, maintenance-free |
| Battery Runtime (full load) | Approx. 5 minutes |
| Battery Runtime (half load) | Approx. 15 minutes |
| Number of Outlets | 8 (battery backup + surge protection) + 2 (surge-only) |
| USB Charging Ports | 2 (1.5A each) |
| Dimensions (H x W x D) | 12.6 x 6.6 x 15.3 inches (320 x 168 x 388 mm) |
| Weight | 30.9 lbs (14.0 kg) |
| Surge Protection | Yes, Joules rating 1400 |
| Automatic Voltage Regulation (AVR) | Yes, Boost and Trim |
| Software Compatibility | APC PowerChute Personal Edition |
| LCD Display | Yes, multifunction with battery status |
| Replacement Battery | APC RBC130 (user-replaceable) |
| Warranty | 3 years (hardware) and 2 years (battery) |
Frequently Asked Questions - Back-UPS Pro BN1350M2 APC
How do I connect the APC Back-UPS Pro BN1350M2?
Plug the UPS into a grounded 120V outlet. Do not use a power strip or extension cord. Then connect your devices (computer, monitor, etc.) to the battery backup outlets. For peripherals like printers, use the surge-only outlets to preserve battery runtime.
What does the LCD display show?
The LCD displays battery charge level, input/output voltage, load percentage in VA/Watts, estimated battery runtime, and alarm status. Use the button to cycle through screens.
How long does the battery last?
At full load (810W), runtime is about 5 minutes. At half load (405W), about 15 minutes. Actual runtime depends on connected devices and battery age.
Can I replace the battery myself?
Yes, the battery is user-replaceable. Order the APC RBC130 replacement battery. Follow the manual for safe replacement. Turn off and unplug the UPS before opening.
How do I connect the UPS to my computer?
Use the included USB cable to connect the UPS data port to your computer. Install APC PowerChute Personal Edition software for automatic shutdown in case of prolonged power outage.
What is the AVR feature?
Automatic Voltage Regulation (AVR) stabilizes utility power by boosting low voltage (brownouts) and trimming high voltage without switching to battery. This extends battery life and protects equipment.
How do I test the UPS?
Press and hold the power button on the front panel for 2 seconds (the button may be labeled 'Test'). The UPS performs a self-test and the LCD will show the result. You can also test via PowerChute software.
Can I use the UPS with a generator?
Yes, but only with a clean sine wave generator. The UPS may not work properly with modified sine wave generators. Ensure the generator output is stable before connecting.
What does the alarm mean?
The UPS sounds an alarm for various conditions: when running on battery, when battery is low (rapid beeping), or when overloaded. Refer to the manual alarm chart for specific patterns.
How do I clean the UPS?
Unplug the UPS and disconnect all equipment. Use a dry, soft cloth to wipe the exterior. Do not use liquids or aerosols. Ensure vents are free of dust for proper cooling.
User questions about Back-UPS Pro BN1350M2 APC
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
No questions yet. Be the first to ask one.
Download the instructions for your Alimentation sans coupure in PDF format for free! Find your manual Back-UPS Pro BN1350M2 - APC and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. Back-UPS Pro BN1350M2 by APC.