Notice SENCOR SAC MT7048C - page 7
Pick your language and provide your email: we'll send you a specifically translated version.
Type Portable air conditioner
Model SAC MT7048C
Brand Sencor
Cooling capacity 7,000 BTU/h (approx. 2.05 kW)
Power supply 220-240 V ~ 50 Hz
Rated power input 800 W
Dimensions (W × D × H) 45 cm × 30 cm × 70 cm
Net weight 25 kg
Refrigerant type R-290 (propane)
Air flow rate 250 m³/h
Noise level ≤ 65 dB(A)
Operating modes Cooling, Fan, Dehumidification
Thermostat control Electronic with LCD display
Timer 24-hour programmable timer
Remote control Included
Caster wheels Yes
Air filter Washable mesh filter
Maintenance Clean filter every 2 weeks; condenser coils annually
Energy efficiency class A (typical)
Safety features Overheat protection, auto restart, child lock
Spare parts availability Remote control, filter, drain hose
Included accessories Exhaust hose, window kit, remote control

Frequently Asked Questions - SAC MT7048C SENCOR

How do I install the portable air conditioner?
Place the unit near a window. Attach the exhaust hose to the back of the unit and connect the window kit to the hose. Close the window onto the kit. Ensure the hose is straight and not bent. Plug in the power and select desired mode.
What does the error code E1 mean?
Error code E1 indicates a sensor fault. Turn off the unit, unplug it for 5 minutes, then restart. If the error persists, contact Sencor service.
How often should I clean the air filter?
Clean the washable air filter every two weeks for optimal performance. Remove the filter, wash with mild detergent, rinse, and dry completely before reinstalling.
Can I use an extension cord?
No, do not use an extension cord or adapter. Plug the unit directly into a properly grounded outlet. Using an extension cord may cause voltage drop and damage the compressor.
What is the recommended room size for this AC?
The SAC MT7048C is suitable for rooms up to 25 m² (approx. 270 sq ft). Actual performance depends on insulation and ceiling height.
Does the unit have a heating function?
No, this model is a cooling-only portable air conditioner. It does not provide heating. Use the fan mode for air circulation.
How do I drain the water?
In dry mode, water accumulates in the internal tank. When full, the unit stops and shows a water full indicator. Remove the drain plug at the back to drain via a hose or bucket. In cooling mode, most water evaporates.
Why is the unit not cooling?
Check if the air filter is clogged, the exhaust hose is properly connected and not blocked, the set temperature is lower than room temperature, and the unit is not too close to walls. Also ensure the window kit is sealed.
Can I use the AC in a room with no window?
No, the unit requires exhaust hose ventilation to expel hot air. It must be vented to the outside via a window, door, or wall opening. Running without exhaust will not cool the room.
How do I set the timer?
Press the Timer button on the remote or control panel. Use + / - to set the desired time (1-24 hours). The unit will start or stop automatically after the set time. Confirm by pressing Timer again.

User questions about SAC MT7048C SENCOR

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Air Conditioning in PDF format for free! Find your manual SAC MT7048C - SENCOR and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. SAC MT7048C by SENCOR.

USER MANUAL SAC MT7048C SENCOR

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : SENCOR

Model : SAC MT7048C

Category : Air Conditioning