Draper

47808 - Pump Draper - Free user manual and instructions

Find the device manual for free 47808 Draper in PDF.

📄 4 pages English EN Download 💬 AI Question 10 questions ⚙️ Specs
Notice Draper 47808 - page 1
Pick your language and provide your email: we'll send you a specifically translated version.
Brand Draper
Model 47808
Product Type Utility Water Pump
Voltage 230 V ~ 50 Hz
Power Rating 750 W (1 HP)
Max Flow Rate 5000 L/h
Max Head 35 m
Inlet / Outlet Size 1" BSP
Housing Material Cast Iron
Impeller Material Stainless Steel
Protection Class IP44
Cable Length 5 m
Dimensions (L x W x H) 200 x 150 x 300 mm
Weight 11.5 kg
Duty Cycle Intermittent (S3 50%)
Max Liquid Temperature 35 °C
Safety Features Thermal overload protection, non-return valve
Maintenance Clean strainer regularly; check seals

Frequently Asked Questions - 47808 Draper

How do I prime the pump?
Fill the pump casing with water through the outlet port before starting. This ensures the impeller is submerged and prevents dry running.
Can the pump handle dirty water?
This pump is designed for clean water only. Do not use with water containing solids larger than 1 mm, as they may clog the impeller or damage the seals.
What is the maximum suction lift?
The maximum suction lift is 8 meters. For optimal performance, keep the suction line as short and straight as possible.
How do I clean the pump?
Disconnect the pump from the power supply. Remove the strainer at the inlet and rinse it with clean water. Use a soft brush to clean the housing if necessary.
Why is the pump not starting?
Check that the power supply is connected and the thermal overload has not tripped. If tripped, allow the pump to cool for 15 minutes and press the reset button.
What type of oil does the pump use?
This pump is oil-free and does not require any oil. The bearings are permanently sealed and lubricated.
Can the pump run dry?
No, never run the pump dry. Dry running can damage the mechanical seal and cause the pump to overheat. Always ensure the pump is primed before operation.
How do I replace the mechanical seal?
Seal replacement requires disassembling the pump. Remove the volute and impeller, then extract the old seal. Install a new mechanical seal and reassemble. Refer to the service manual for detailed steps.
Is the pump suitable for salt water?
No, this pump is not designed for salt water or corrosive fluids. The cast iron housing and stainless steel parts may still corrode in saline environments. Use a specifically designed pump for such applications.
What is the warranty period?
Draper offers a 2-year warranty from the date of purchase. The warranty covers manufacturing defects but not wear and tear or damage from misuse.

User questions about 47808 Draper

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Pump in PDF format for free! Find your manual 47808 - Draper and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. 47808 by Draper.

USER MANUAL 47808 Draper

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : Draper

Model : 47808

Category : Pump