| Product Type | Compact Laser Displacement Sensor |
| Model | HG-C1100 |
| Brand | Panasonic |
| Measurement Range | 10-100 mm |
| Light Source | Red semiconductor laser, wavelength 655 nm |
| Laser Class | Class 2 (IEC 60825-1) |
| Power Supply | 12-24 V DC (±10%) |
| Current Consumption | Max. 40 mA |
| Output | Analog voltage (0-5 V) or digital (NPN/PNP) |
| Resolution | 0.5 mm (typical) |
| Accuracy | ±1% of full scale |
| Response Time | 1 ms |
| Temperature Drift | ±0.03% of FS/°C |
| Dimensions (W x H x D) | 20 x 15 x 6 mm (approx.) |
| Weight | Approx. 20 g |
| Protection Rating | IP67 |
| Operating Temperature | -10 to +50 °C |
| Storage Temperature | -20 to +70 °C |
| Maintenance | Clean lens with soft cloth; no user-serviceable parts |
| Safety Precautions | Avoid direct eye exposure; use only in accordance with instructions |
| Included Accessories | Instruction manual, mounting bracket (optional) |
| Compliance | CE, FDA/CDRH |
Frequently Asked Questions - HG-C1100 PANASONIC
User questions about HG-C1100 PANASONIC
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
Download the instructions for your Laser pointer in PDF format for free! Find your manual HG-C1100 - PANASONIC and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. HG-C1100 by PANASONIC.
USER MANUAL HG-C1100 PANASONIC
Conforming to EMC Directive
FDA
Conforming to FDA regulations
Reliable detection
in 10µm precision

Repeatability
10 μm (for HG-C1030)
Dimensions
W20 × H44 × D25 mm
Inflection resistant cable
Available for all models

| Item\Model No. | HG-C1030 | HG-C1050 | HG-C1100 | HG-C1200 | HG-C1400 |
| Measurement center distance | 30 mm 1.181 in | 50 mm 1.969 in | 100 mm 3.937 in | 200 mm 7.874 in | 400 mm 15.748 in |
| Measurement range | ±5 mm 0.197 in | ±15 mm 0.591 in | ±35 mm 1.378 in | ±80 mm 3.150 in | ±200 mm 7.874 in |
| Beam diameter | Approx.ø50 μm1.969 mil | Approx.ø70 μm2.756 mil | Approx.ø120 μm4.724 mil | Approx.ø300 μm11.811 mil | Approx.ø500 μm19.685 mil |
| Repeatability | 10 μm0.394 mil | 30 μm1.181 mil | 70 μm2.756 mil | 200 μm7.874 mil | 300 μm 11.811 mil(Measuring distance 200 to 400mm7.874 to 15.748 in)800 μm 31.496 mil(Measuring distance 400 to 600mm15.748 to 23.622 in) |
Overwhelmingly stable
Precise measurements on the order of 1/100 mm 0.0003 inch
Excellent level detection performance
Repeatability: 10 μm (for HG-C1030)






Fitted with a precise CMOS image sensor and an original algorithm
MICRO LASER DISTANCE SENSOR

Linearity: ±0.1% F.S. (for HG-C1030 / HG-C1050 / HG-C1100)
Compact
The smallest CMOS laser sensor in the industry* *Based on research conducted by our company as of May 2015

Measuring the insertion depth of an actuator
Compact and light-weight
W20 × H44 × D25 mm, approx. 35 g (excluding the cable)
Long distance measurement
Measurement center distance: 400 mm (for HG-C140), 200 mm (for HG-C1250)








Remove water droplets on detection surface to achieve correct measurement.


Equipped with 0-5 V analog output
The value can be measured with a distance sensor.
• Linearity: ±0.1% FS* • Temperature characteristics: 0.03% F.S./°C
The sensor not only indicates measured values in mm but also produces analog voltage outputs. Various calculations and storage (logging) can be performed when output is taken into a PLC + analog unit.

*For HG-C1030 / HG-C1050 / HG-C1100
■Linearity characteristics
(Typical example: HG-C1030)
A new optical system with a built-in mirror
In general, more accurate and stable measurements can be obtained by increasing the optical path length between the receptor and the light receiving element (CMOS), but this also increases the sensor depth and the sensor body gets bigger. The HG-C series sensors incorporating a new optical system with a built-in mirror provides smaller sensor depth as well as higher measurement accuracy equivalent to displacement sensors.

An aluminum die-cast casing protects from strain and heat
A light-weight but strong die-cast aluminum casing has been adopted. A compact, solid body casing reduces the impact of strain and heat on the measurement accuracy.
Aluminum die-cast casing


Useful functions
Teaching & window comparator mode
With an object below the sensor, press the TEACH key to set the valid range for distances via threshold values. There are 3 methods for setting the valid range: 1-point, 2-point, and 3-point teaching.
1-point teaching![graph TD A["Sensing object present"] --> B["Distance"] B --> C["SET to Light-ON"] C --> D["ON"] D --> E["Threshold value"] D --> F["OFF"] G["TEACH ①"] --> H["Reference point"] H --> I["ON"] I --> J["Threshold value"] J --> K["OFF"]](/content/2026/06/1401646/images/0d50ca40050a3cb857b781b60e9700c7fcb5c14bdead778894a4547cf406ad7b.jpg)
Perform 1-point teaching and the threshold range is set for the distance from the reference surface of the sensing object.
2-point teaching
Press TEACH once for the lower (first point) and once for the upper limit (second point). Useful for sensing objects at different distances.
3-point teaching
This is the method to set the threshold range by conducting the teaching at 3 points (sensing object A, B and C). After teaching, the reference points are automatically sorted in ascending order (reference point 1, 2 and 3). The thresholds are set at the midpoints between reference point 1 and 2, and 2 and 3, respectively. Useful for sensing objects at different distances. In addition to the teaching & window comparator mode, the "rising differential mode", "trailing differential mode" and "normal sensing mode" are available. In normal sensing mode, "2-point teaching" as basic teaching and "limit teaching," which is useful for very small objects and backgrounds, are possible.

Timer setting function
The time mode options are "off-delay timer," "on-delay timer," "one-shot timer" and "no timer." The counting time is fixed to 5 ms.
![graph TD A["Sensing level"] --> B["Off-delay timer"] B --> C["On-delay timer"] C --> D["One-shot timer"] style A fill:#f9f,stroke:#333 style B fill:#bbf,stroke:#333 style C fill:#bfb,stroke:#333 style D fill:#ffb,stroke:#333](/content/2026/06/1401646/images/2983dec5fd9b47db469e1a209a9b379c65cf91163e1bd9d786c97bbef76044f8.jpg)
Timer period: 5 ms (fixed)
Off-delay timer
Function: Extends output signals by 5 ms.
Usage: Appropriate in case a connected device is slow to respond and ON time is required to extend.
On-delay timer
Function: Overrides output signals for 5 ms after detection.
Usage: Convenient way to override temporary signals and control with a time lag.
One-shot timer
Function: Sends output signals for only 5 ms after detection.
Usage: Useful when the signal duration needs to be constant to meet inputs from a connected device. This mode is also used to extend temporary signals by a desired length of time.
Zero set function
This function compulsorily sets the measured value to "zero." The zero point can be set at a desired value. It is useful when measuring steps or tolerance with reference to the height of a sensing object.



Keep pressing both keys for 3 seconds.
* The zero set indicator (yellow) will turn ON while the zero set is valid. * When the zero set function is executed while the peak hold function or the bottom hold function is valid, the held measurement value is reset. * When the display setting is set to offset, the zero set function cannot be set.
External input setting function
One of four functions, "zero setting function," "teaching function," "emission stopping function" and "trigger function" can be assigned to an external input line.

Display setting function
How to indicate measured values of the moving sensed object can be chosen from three options, "Normal," "Invert" and "Offset."
Example: HG-C1050
| Outside the measuring range | Measuring near point | Measurement center | Measuring far point | Outside the measuring range | |
![]() | ![]() | ![]() | ![]() | ![]() | ![]() |
■Relation between the setting display and the analog voltage output

Peak and bottom hold functions
The peak hold function holds the maximum measured value which is output and displayed.
The bottom hold function holds the minimum measured value which is output and displayed.
* The peak hold function and the bottom hold function cannot be set at the same time. * When the zero set function is executed while the peak hold function or the bottom hold function is valid, the held measurement value is reset.
Threshold value fine adjustment function
Fine adjustment of threshold values can be performed while measurement is proceeding on the display, and even after teaching.
Key lock function
This function protects setting conditions from unintentional changes.
| Type Appearance | Measurement center distance and measurement range | Repeatability | Beam diameter (Note) | Model No. | |
| NPN output | PNP output | ||||
| Measurement center 30mm type | | 30 ± 5 mm1.181 ± 0.197 in | 10 μm0.394 mil | Approx. ø50 μm1.969 mil | HG-C1030 HG-C1030-P |
| Measurement center 50mm type | 50 ± 15 mm1.969 ± 0.591 in | 30 μm1.181 mil | Approx. ø70 μm2.756 mil | HG-C1050 HG-C1050-P | |
| Measurement center 100mm type | 100 ± 35 mm3.937 ± 1.328 in | 70 μm2.756 mil | Approx. ø120 μm4.724 mil | HG-C1100 HG-C1100-P | |
| Measurement center 200mm type | 200 ± 80 mm7.874 ± 3.150 in | 200 μm7.874 mil | Approx. ø300 μm11.811 mil | NEWHG-C1200 HG-C1200-P | |
| Measurement center 400mm type | 400 ± 200 mm15.748 ± 7.874 in | 300 μm 11.811 mil(Measuring distance 200 to 400 mm 7.874 to 15.748 in)800 μm 31.496 mil(Measuring distance 400 to 600 mm 15.748 to 23.622 in) | Approx. ø500 μm19.685 mil | NEWHG-C1400 HG-C1400-P | |
Note: This is the size at the measurement center distance. These values were defined using 1/e2 (approx. 13.5%) of the center light intensity. Due to light leakage outside the specified area, the reflectance around the detection point may be higher than at the point itself, which may affect the measurement value.
SPECIFICATIONS
| Type | Measurement center 30mm type | Measurement center 50mm type | Measurement center 100mm type | Measurement center 200mm type | Measurement center 400mm type | |||||||
| Item | NPN output | HG-C1030 HG-C1050 HG-C1100HG-C1200 HG-C1400 | ||||||||||
| PNP output | HG-C1030-P HG-C1050-P HG-C1100-P HG-C1200-P HG-C1400-P | |||||||||||
| Applicable standard EMC Directive Compliance, FDA Standard | ||||||||||||
| Measurement center distance | 30 mm 1.181 in | 50 mm 1.969 in | 100 mm 3.937 in | 200 mm 7.874 in | 400 mm 15.748 in | |||||||
| Measurement range | ±5 mm 0.197 in | ±15 mm 0.591 in | ±35 mm 1.328 in | ±80 mm 3.150 in | ±200 mm 7.874 in | |||||||
| Repeatability | 10 μm 0.394 mil | 30 μm 1.181 mil | 70 μm 2.756 mil | 200 μm 7.874 mil | 300 μm 11.811 mil(Measuring distance 200 to 400 mm 7.874 to 15.748 in)800 μm 31.496 mil(Measuring distance 400 to 600 mm 15.748 to 23.622 in) | |||||||
| Linearity | ±0.1 % F.S. | ±0.2 % F.S. | ±0.2 % F.S.(Measuring distance 200 to 400 mm 7.874 to 15.748 in)±0.3 % F.S.(Measuring distance 400 to 600 mm 15.748 to 23.622 in) | |||||||||
| Temperature characteristic | 0.03 % F.S./°C | |||||||||||
| Light source | Red semiconductor laser Class 2 [JIS/IEC/GB/FDA (Note 2)] Max. output: 1 mW, emission peak wavelength: 655 nm 0.026 mil | |||||||||||
| Beam diameter (Note 3) | Approx. ø50 μm 1.969 mil | Approx. ø70 μm 2.756 mil | Approx. ø120 μm 4.724 mil | Approx. ø300 μm 11.811 mil | Approx. ø500 μm 19.685 mil | |||||||
| Supply voltage | 12 to 24 V DC ±10 %, Ripple P-P 10 % or less | |||||||||||
| Power consumption | 40 mA or less (at 24 V DC supply voltage), 60 mA or less (at 12 V DC supply voltage) | |||||||||||
| Control output | NPN open-collector transistorMaximum sink current: 50 mAApplied voltage: 30 V DC or less (Between control output to 0V)Residual voltage: 1.5 V or less (At 50 mA sink current)Leakage current: 0.1 mA or less | PNP output type>PNP open-collector transistorMaximum source current: 50 mAApplied voltage: 30 V DC or less (Between control output to +V)Residual voltage: 1.5 V or less (At 50 mA source current)Leakage current: 0.1 mA or less | ||||||||||
| Either Light-ON or Dark-ON | ||||||||||||
| Incorporated (Auto reset type) | ||||||||||||
| Analogue output | Output range: 0 to 5 V (at alarm: +5.2 V)Output impedance: 100 Ω | |||||||||||
| Response time | Switchable between 1.5 ms / 5 ms / 10 ms | |||||||||||
| External input | NPN non-contact inputInput conditionsInvalid: +8 to +V DC or OpenValid: 0 to +1.2 V DCInput impedance: Approx. 10 kΩ | PNP output type>PNP non-contact inputInput conditionsInvalid: 0 to +0.6 V DC or OpenValid: +4 to +V DCInput impedance: Approx. 10 kΩ | ||||||||||
| Degree of pollution | 2 | |||||||||||
| Operating altitude | 2,000 m 6561.680 ft or less | |||||||||||
| Environmental resistance | Protection | IP67 (IEC) | ||||||||||
| Ambient temperature | -10 to +45 °C -14 to 113 °F (No dew condensation or icing allowed), Storage: -20 to +60 °C -4 to 140 °F | |||||||||||
| Ambient humidity | 35 to 85 % RH, Storage: 35 to 85 % RH | |||||||||||
| Ambient illuminance | Incandescent lamp: Acceptance surface illuminance 3,000 tx or less | |||||||||||
| Vibration resistance | 10 to 55 Hz (period: 1 min.) frequency, 1.5 mm 0.059 in amplitude in X, Y and Z directions for two hours each | |||||||||||
| Shock resistance | 500 m/s2 acceleration (50 G approx.) in X, Y and Z directions for three times each | |||||||||||
| Cable | 5-core composite cable, 2 m 6.5617 ft long | |||||||||||
| Cable extension | Extension up to total 10 m 393.701 ft is possible with 0.3 mm2, or more, cable. | |||||||||||
| Material | Enclosure: Aluminum die-cast, Front cover: Acrylic | |||||||||||
| Weight | Net weight: approx. 35 g (without cable), approx. 85 g (including cable) | |||||||||||
Notes: 1) Supply voltage: 24 V DC, ambient temperature: +20 °C (+68 °F), response time: 10 ms, and analog output value at the measurement center distance are used for unspecified measurement conditions. The subject is white ceramics. 2) This is based on the FDA Standard, according to Laser Notice No. 50 of the FDA Standard. 3) This is the size at the measurement center distance. These values were defined using 1/e2 (approx. 13.5%) of the center light intensity. Due to light leakage outside the specified area, the reflectance around the detection point may be higher than at the point itself, which may affect the measurement value.
OPTIONS
| Designation | Model No. | Description |
| Simple mounting bracket (Note) | Foot angled mounting bracket |
Note: Due to the simple mounting bracket, the sensing characteristics may not be maintained depending on the installation conditions, especially when the purpose is to acquire displacement data or perform fine detection.
Simple mounting bracket · MS-HG-01
Material: Stainless steel (SUS304)
Two M3 screws (length 25 mm / 0.984 in) with washers (SPCC) are attached.

I/O CIRCUIT DIAGRAMS
NPN output type
*1
Non-voltage contact or NPN open-collector transistor - External input
Invalid: +8 to +V DC or open
Valid: 0 to +1.2 V DC
PNP output type
*1
Non-voltage contact or PNP open-collector transistor - External input
Invalid: 0 to +0.6 V DC or open
Valid: +4 to +V DC
SENSING CHARACTERISTICS (TYPICAL)
Linearity
HG-C1030(-P)
HG-C1050(-P)
HG-C1100(-P)
HG-C1200(-P)
HG-C1400(-P)
PRECAUTIONS FOR PROPER USE
- This catalog is only provided to help choose a product and the user's guide attached to the product must be read before use.

- Never use this product as a sensing device for personnel protection.
- In case of using sensing devices for personnel protection, use products which meet laws and standards, such as OSHA, ANSI or IEC etc., for personnel protection applicable in each region or country.

- Do not operate products using methods other than the ones described in the instruction manual included with each product. Control or adjustment through procedures other than the ones specified may cause hazardous laser radiation exposure.

- This product is classified as a Class 2 Laser Product under JIS / IEC / GB standards and FDA * regulations. Do not look at the laser beam directly or through an optical system such as a lens.
- The warning label (English) is attached to the product. Handle the product according to the instruction given on the warning label. (The warning labels in Japanese and Chinese are packed with the sensor.)

* The product complies with the FDA regulations and satisfies requirements of the FDA's Laser Notice No. 50.
Part description
PRO mode setting
| Item | Default setting | Description |
| Response speed setting | Hr5o | Set the response time.“H:High precision 10ms, “”:Standard 5ms,“F:High speed 1.5ms |
| Output operation setting | L-on | Select the control output operation mode.“L-on”: Light-ON, “d”: Dark-ON |
| Sensing output setting | Set the sensing output.“:Normal sensing mode“R1-point teaching (Window comparator mode)“R2-point teaching (Window comparator mode)“R3-point teaching (Window comparator mode)“d”: Rising differential mode“d”: Trailing differential mode | |
| Hysteresis setting | Set the hysteresis width.HG-C1030: 0.001 to 5.00 mm 0.00004 to 0.197 inHG-C1050: 0.01 to 15.00 mm 0.00039 to 0.591 inHG-C1100: 0.02 to 35.00 mm 0.00079 to 1.378 inHG-C1200: 0.1 to 80.0 mm 0.00394 to 3.150 inHG-C1400: 0.2 to 200.0 mm 0.00787 to 7.874 in | |
| External input setting | OSET | Set the external input.“05Zero set function, “”:Teaching function“L”:Light emitting stop function, “”:Trigger function |
| Timer setting | non | Set the timer operation. The timer time is fixed at 5ms.“”No timer, “”:OFF delay timer“”ON-delay timer, “”:One-shot timer |
| Display setting | Std | The display of the measured value can be changed.“”Normal, “”:Invert“”:Offset oFSt |
| Hold setting | oFF | Set the control output and the analogue output operation when a measurement error occurs (insufficient light intensity, saturation of light intensity, out of measurement range).“”Hold OFF, “”: HoldON |
| ECO Setting | The digital display can be set to go OFF when key operation is not performed for 30 seconds. Current consumption can be reduced.“”ECO OFF, “”: ECOON | |
| Reset setting | no | Return to the default setting (factory setting).“”: Reset NG, “”: Reset OK |
Procedure![graph TD A["Measurement display"] --> B["Response time setting"] B --> C["Output operation setting"] C --> D["Sensing output setting"] D --> E["Hysteresis setting"] E --> F["External input setting"] F --> G["Timer setting"] G --> H["Display setting Normal Invert Offset"] H --> I["Hold setting"] I --…](/content/2026/06/1401646/images/c2f80ec846479afc4c18fdbfb14c865885f7ee5c4ff604c5bbca2968c7ee101e.jpg)
← : Press the TEACH key
← : Press UP key or DOWN key
←→: Press DOWN key
Mounting
- When mounting this product, use M3 screws. The tightening torque should be 0.5 N·m. Please prepare M3 screws separately.

- When mounting the simple mounting bracket (optional) on this product, the tightening torque should be 0.5 N·m or less.

Note: Due to the simple mounting bracket, the sensing characteristics may not be maintained depending on the installation condition, especially when the purpose is to acquire displacement data or perform fine detection.
Mounting direction
- Direction to a movable body
- When performing measurements of moving objects with excessively different materials and colors, mount the product according to the following directions to minimize measurement errors.

- When measuring rotating objects, mount the product as follows. Measurement can be performed with minimized effect on the object caused by up/down deflection, position deviation, etc.

- When there is a step in the moving object, mount the product as follows. Measurement can be performed with minimized effect from the edges of the steps.

• Measuring of narrow locations and recesses
- When measuring in narrow locations or inside holes, mount the product so that the optical path from the light-emitting part to the light-receiving part is not interrupted.

- When mounting the product on a wall
- Mount the product as follows, so that the multiple light reflections on the wall do not emit to the light-receiving part. When the reflection factor on a wall is high, it is effective to use a dull black color.

Others
- This product has been developed/produced for industrial use only.
- Make sure that the power supply is OFF before starting the wiring.
- If the wiring is performed incorrectly, it will cause a failure.
- Do not run the wires together with high-voltage lines or power lines, or put them in the same raceway. This can cause malfunction due to induction.
- Verify that the supply voltage variation is within the rating.
- If power is supplied from a commercial switching regulator, ensure that the frame ground (F.G.) terminal of the power supply is connected to an actual ground.
- If noise generating devices (switching regulators, inverter motors, etc.) are used around the sensor mounting area, make sure to connect the frame ground (FG) terminal of the device.
- Do not use this product during the transient state when the power supply is turned ON.
- The overall length of the cable can be extended to 10m maximum with a cable size of 0.3 mm² or more.
- Make sure that stress by forcible bend or pulling is not applied to the sensor cable joint.
- Although it depends on the type, light from rapid start type or high frequency lighting type fluorescent lights, sunlight, and etc. may affect the sensing, therefore make sure to prevent direct incident light.
- This product is suitable for indoor use only.
- Keep water, oil, fingerprints, and etc. which reflect light, or dust, particles, or etc. which interrupts the light, away from the emitting / receiving surfaces of this product. If contaminants adhere to the surface, wipe off with a dust-free soft cloth, or lens cleaning paper.
- Do not use the sensor in locations where there is excessive vapor, dust, or etc. or in an atmosphere where corrosive gases, etc. is generated.
- Take care that the product does not come in contact with oil, grease, organic solvents such as thinner, etc., strong acid or alkaline.
- Make sure to turn OFF the power supply, before cleaning the light emitting / receiving windows of the sensor head.
Error indication
- In case of errors, attempt the following measures.
| Error indication Description Remedy | ||
| Insufficient amount of reflected light.The sensing object is out of the sensing range. | Confirm that the sensing distance is within the specification range.Adjust the installation angle of the sensor. | |
| Measured value blinks | ||
| Er01 | Flash memory is damaged or is past its life expectancy. | Please contact our office. |
| Er11 | Load of the sensing output is short-circuited causing an over-current to flow. | Turn OFF the power and check the load. |
| Er21 | The semiconductor laser is damaged or is past its life expectancy. | Please contact our office. |
| Er31 | When zero set is set, the measurement is not performed normally.Since the display setting is set to “Offset”, the zero set function can not be used. | Confirm that the sensing distance is within the specification range.Set the display to any setting except “Offset.” |
| Er41 | During teaching, the measurement is not performed normally. | Confirm that the sensing distance is within the specification range. |
| Er90Er91Er92Er93 | System error Please contact our office. | |
DIMENSIONS (Unit: mm in)
CAD data can be downloaded from our website.
HG-C□
Sensor

| Model No. | Measurement center distance (L) | θ |
| HG-C1030(-P) | 30 1.181 30° | |
| HG-C1050(-P) | 50 1.969 22.5° | |
| HG-C1100(-P) | 100 3.937 12.5° | |
| HG-C1200(-P) | 200 7.874 6.3° | |
| HG-C1400(-P) | 400 15.748 3.2° |
MS-HG-01
Simple mounting bracket (Optional)
Material: Stainless steel (SUS304) Two M3 (length 25 mm 0.984 in) screws with washers (SPCC) are attached.
Introducing our laser sensors
Laser Displacement Sensor
Compact
HL-G1 SERIES
High-precision measurement is achieved at a resolution of 0.5 μm 0.02 mil (HL-G103). Easy to embed in machines and production lines thanks to a built-in controller.

Full lineup! 10 models of diffuse reflection type (class 2) and 6 models of specular reflection type (class 1) are available. They accommodate a variety of applications.
Digital Laser Sensor
LS-500 SERIES
Industry's smallest* laser sensor head,
fastest response time* 60 μs.
* As of September 2013, as amplifier-separated type laser sensor amplifier, based on research conducted by us.



Engineered for maximum compatibility with fiber sensors in every aspect of its design, form and operability. The LS-500 delivers an environment that makes it easy to choose a class 1 laser sensor.
Please contact :
Panasonic Industrial Devices SUNX Co., Ltd.
2431-1 Ushiyama-cho, Kasugai-shi, Aichi, 486-0901, Japan
Global Sales Department
Telephone: +81-568-33-7861, Facsimile: +81-568-33-8591
panasonic.net/id/pidsx/global
Panasonic®
All Rights Reserved ©Panasonic Industrial Devices SUNX Co., Ltd. 2015