PCE Instruments

IT 200 - Multimeter PCE Instruments - Free user manual and instructions

Find the device manual for free IT 200 PCE Instruments in PDF.

📄 12 pages English EN Download 💬 AI Question 10 questions ⚙️ Specs
Notice PCE Instruments IT 200 - page 6
Pick your language and provide your email: we'll send you a specifically translated version.
Product Type Digital Multimeter
Brand PCE Instruments
Model IT 200
Dimensions (approx.) 150 x 70 x 30 mm
Weight (approx.) 200 g
Power Supply 9V battery (6F22 type)
Display LCD, max reading 2000 counts
DC Voltage Range 200 mV to 600 V, accuracy ±0.5%
AC Voltage Range 200 V to 600 V, accuracy ±1.2%
DC Current Range 200 µA to 10 A, accuracy ±1.0%
Resistance Range 200 Ω to 20 MΩ, accuracy ±0.8%
Capacitance Measurement 2 nF to 200 µF
Frequency Measurement Up to 20 kHz
Continuity Test Audible beep below 50 Ω
Diode Test Yes, open circuit voltage ~3V
Safety Rating CAT III 600 V
Auto-ranging Yes
Data Hold Yes
Backlight Yes
Maintenance & Cleaning Wipe with dry cloth; do not use solvents
Spare Parts / Repairability Test leads, battery, fuse accessible

Frequently Asked Questions - IT 200 PCE Instruments

How do I measure AC voltage with the IT 200?
Turn the rotary dial to the AC voltage range (V~). Insert the black lead into COM and red lead into VΩHz. Connect the probes to the circuit. Read the display.
How do I replace the battery?
Turn off the multimeter. Remove the screw on the back cover. Lift the cover. Replace the 9V battery (6F22). Reattach the cover and tighten the screw.
What does the continuity test do?
The continuity test checks if a circuit is complete. It emits a beep when resistance is below about 50 Ω. Useful for checking wires and fuses.
How do I use the Data Hold function?
Press the HOLD button to freeze the current reading on the display. Press again to release. Useful for measuring in dimly lit or hard-to-reach areas.
What is CAT III safety rating?
CAT III (Category III) means the meter is protected against transient overvoltages in fixed installation circuits, such as distribution panels, lighting, and motors. Suitable for industrial and building installation testing.
How do I measure resistance?
Turn the dial to the Ω range. Connect black lead to COM and red lead to VΩHz. Disconnect power from the circuit. Touch probes to the resistor or component. Read the value.
What should I do if the display shows no reading?
Check the battery. Replace if low. Ensure the test leads are properly connected. Verify the dial is set to the correct function. If still no reading, replace the test leads or check the internal fuse.
How do I clean the multimeter?
Turn off the meter and remove the test leads. Wipe the casing with a soft, dry cloth. Do not use water, solvents, or abrasive cleaners. Avoid getting moisture inside.
Can I measure DC current with this multimeter?
Yes. Turn the dial to the DC current (A-) range. Insert black lead into COM and red lead into the 10A or mA jack depending on expected current. Break the circuit and connect the meter in series. Read the display.
What accessories are included with the IT 200?
Typically includes: multimeter unit, pair of test leads, 9V battery, and user manual. Some packages may include a carrying case or thermocouple (check the box).

User questions about IT 200 PCE Instruments

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Multimeter in PDF format for free! Find your manual IT 200 - PCE Instruments and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. IT 200 by PCE Instruments.

USER MANUAL IT 200 PCE Instruments

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : PCE Instruments

Model : IT 200

Category : Multimeter