Product Type Range Hood
Model FV-15NLFS1H
Brand Panasonic
Installation Type Under-cabinet / Wall-mounted
Width 600 mm
Depth 500 mm
Height (min) 150 mm
Weight Approx. 8 kg
Power Supply 220-240 V, 50 Hz
Power Consumption 100 W
Max Airflow 400 m³/h
Noise Level 50 dB (A)
Control Type Push buttons
Lighting LED, 2 x 3 W
Filter Type Aluminum grease filter, washable
Ducting Top or rear outlet, 150 mm diameter
Recirculation Capable Yes (with optional charcoal filter)
Energy Class A+
Maintenance Clean grease filter monthly; replace charcoal filter every 3-6 months
Safety Features Overheat protection, auto shut-off
Spare Parts Filters, bulbs, control board available from service centers
Repairability Index 8/10

Frequently Asked Questions - FV-15NLFS1H PANASONIC

How do I install the Panasonic FV-15NLFS1H range hood?
Installation should be performed by a qualified professional. Ensure the hood is mounted securely under a cabinet or on the wall, with proper ducting to the outside or using a recirculation kit. Refer to the user manual for detailed steps and safety precautions.
How do I clean the grease filter?
The aluminum grease filter is washable. Remove it and clean with warm soapy water or in a dishwasher. Allow it to dry completely before reinstalling. For best performance, clean every month.
How do I replace the charcoal filter for recirculation mode?
To use recirculation mode, you need an optional charcoal filter. Install it behind the grease filter. Replace the charcoal filter every 3 to 6 months depending on usage.
Why is my range hood noisy?
Noise can be due to loose installation, blocked ducting, or a dirty filter. Ensure the hood is securely mounted, the ducting is clear, and the grease filter is clean. If noise persists, check the fan motor for issues.
How do I change the LED lights?
The LED lights are integrated and may require replacing the entire light assembly. Contact Panasonic service center for assistance. Do not attempt to replace with non-specified bulbs.
Does this hood come with a remote control?
No, the FV-15NLFS1H is controlled via push buttons on the unit. No remote control is included.
Can I use this hood without ducting to the outside?
Yes, the hood can be used in recirculation mode by installing an optional charcoal filter. The air will be filtered and recirculated back into the kitchen.
What is the recommended installation height above the cooktop?
For gas cooktops, install the hood at least 65 cm above; for electric cooktops, 55 cm. Refer to the manual for exact recommendations.
How do I reset the filter reminder?
After cleaning or replacing the filter, press and hold the filter reset button (if equipped) for 3 seconds until the indicator light turns off. Refer to the manual for specific instructions.
Where can I find spare parts or service?
Contact Panasonic authorized service centers or visit the official website. Spare parts include filters, bulbs, and control boards. Use only genuine Panasonic parts for safety.

User questions about FV-15NLFS1H PANASONIC

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

Your email remains private: it is only used to notify you if someone answers your question.

No questions yet. Be the first to ask one.

Download the instructions for your Range hood in PDF format for free! Find your manual FV-15NLFS1H - PANASONIC and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. FV-15NLFS1H by PANASONIC.

USER MANUAL FV-15NLFS1H PANASONIC

PANASONIC FV-15NLFS1H - 1

WARNING

This service information is designed for experienced repair technicians only and is not designed for use by the general public. It does not contain warnings or cautions to advise non-technical individuals of potential dangers in attempting to service a product. Products powered by electricity should be serviced or repaired only by experienced professional technicians. Any attempt to service or repair the product or products dealt with in this service information by anyone else could result in serious injury or death.

IMPORTANT SAFETY NOTICE

There are special components used in this equipment which are important for safety. These parts are marked by ⚠ in the Schematic Diagrams, Exploded Views and Replacement Part List. It is essential that these critical parts are replaced with manufacturer's specified parts to prevent shock, fire or other hazards. Do not modify the original design without permission from the manufacturer. We suggest handling such parts after static electricity prevention. It is forbidden to touch the PCB parts with bare hands during the repairing process.

CONTENTS

PAGE

  1. Specifications 1 2. Parts Identification 2~4 3. Wiring Diagram 5 4. Parts List 6,7

1. Specifications

Air directionVoltage (V)Frequency (Hz)Duct (inch)Static pressureAir volume (CFM)Power consumption (W)Speed (rpm)Weight lb(kg)
Supply1206060.2"WG508.298913.4(6.1)
609.31012
70101033
8012.41067
9013.51086
10015.31121
11016.71152
13022.61235
15027.31314

Air volume performance based on HVI Procedures 916 and 920.

2. Parts Identification

FV-15NLFS1H

Main BodyPANASONIC FV-15NLFS1H - Parts Identification - 1

2. Parts Identification

FV-15NLFS1H

Fan Assy. 26 25 24 23 27 22 21 B (4 pcs) A (4 pcs) 20 19 A (4 pcs) 18

Main PCB.PCB. 28 A (4 pcs) 29 30 31 B (6 pcs) 33 (3 pcs) 34 35 32

2. Parts Identification

FV-15NLFS1H

MAIN LABEL38 (3 pcs) 39 40 41 (2 pcs) 42 (2 pcs) 43 44

3. Wiring diagram

FV-15NLFS1H

PANASONIC FV-15NLFS1H - Wiring diagram - 1

graph LR A["DC Motor / Moteur c.c / Motor D.C"] --> B["Main control circuit / Circuit de commande principal / Circuito de control principal"] B --> C["Main switch / Interrupteur principal / Interruptor principal"] C --> D["Black / Noir / Negro"] C --> E["White / Blanc / Blanco"] C --> F["Green / Ver…

AC 120 V, 60 Hz (Power supply) / 120 V AC, 60 Hz (Power supply) / 120 V AC, 60 Hz (Power supply) Earth ground / Earth ground / Earth ground Neutral / Neutral / Neutral Neutral / Earth ground / Earth ground Neutral / Neutral / Neutral Live / Live / Live Wall Switches / Wall Switches / Wall Switches

Main Body

No.Part No.Part NameQ'ty Remark
1FFV15NLF290FrameAssy 1
2FFV15NLF904InletAdapter 1
3FFV15NLF903DischargeAdapter 1
4FFV06VE1912JunctionCover 1
5FFV3450010SEarthLead wire1
6FFV15NLF301ConnectorAssy 1
7FFV15NLFS1FanAssy1
8FFV15NLF915EathPlate 1
9FFV15NLF914L Plate1
10FFV15NLF195PreFilter Assy 1
11FFVFL131595MERV13 Filter1
12FFV15NLF918FanGuard 1
13FFV15NLFS1HMain PCB Assy1
14FFV15NLF103PCBwiring Cover 1
15FFV15NLF134WaterProof Cover1
16FFV15NLF291MotorPanel 1
17FFV4620133SPressure Plug1
AFFV7000074STruss Tap Screw20
BFFVXYM4DC8BNBind Screw W/Washer2
CFFVXTT510CFJTruss Tap Screw1
DFFVXTT412GFJTruss Tap Screw6
EFFV00TMM0501Tsumami2

Fan Assy

NoP a rt No . P a rt Na m e Q 'ty Re m a rk
1 8F F V 3 7 3 0 1 29MMo to r B ase 1
1 9F F V 1 5 NLF 1 M2Mo to r S e t 1
2 0F F V 3 7 3 0 1 27MMo to r Ho ld e r P late1
2 1F F V 1 0 VC 2 9 4 3Mo to r Ho ld e r1
2 2F F V 7 0 1 0 0 55SW asher1
2 3F F V 1 0 VC 2 9 4 8B lad e1
2 4F F V 1 0 VC 2 R 9F ix P late1
25F F V 7 0 2 0 0 22SNut1
26F F V VC 2 M9 4 2C as ing1
27F F V 4 7 1 0 4 08MC as ing P ac king1
AFFV7000074STruss Tap Screw8
BFFV7000089STruss Tap Screw4

Main PCB Assy

NoPart No . Part Name Q 'tyRemark
28FFV15 NLF031PCB Box Cover1
29FFV0010222SWet Sensor1PANASONIC FV-15NLFS1H - Wiring diagram - 4
30FFV15 NLF036S ns or Cap1
31FFV15 NLF310Power Lead Wire1PANASONIC FV-15NLFS1H - Wiring diagram - 5
32FFV15 NLF203Humidity Sensor Wire1PANASONIC FV-15NLFS1H - Wiring diagram - 6
33FFV13 KML3MSwitch K no w3
34FFV13 KML398Switch S p ring1
35FFV15 NLF032Main PCB Box1
AFFVXTT412GT juss Tap Screw4
BFFVXTN268GFS c re w6

Packing Case

NoP a rt No . P a rt Na m e Q 'ty Re m a rk
36FFV15NLF070Maintenance Label1
37F F V 1 5 NLF 0 71S witch h L ab e l1
38F F V 1 5 NLF 2 98Hang e r3
39F F V 1 5 NLF 4 20Installation Inst (EFS)1
40F F V 1 5 NLF 4 30A c cess o ry S e t1
41F F V 1 5 NLF 8 91F o am P ad1
42FFVWC10V14Poly Cover W /Print1
43FFV15NLF400Packing Case1
Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : PANASONIC

Model : FV-15NLFS1H

Category : Range hood