| Product Type | Handheld Barcode Reader (Barcode Scanner) |
| Model | Cino F680 |
| Dimensions (approx.) | 170 x 70 x 100 mm (typical handheld) |
| Weight (approx.) | 200 g (typical with cable) |
| Power Supply | 5V DC via USB or RS232 (cable supplied) |
| Interfaces | USB Virtual COM, RS232, Bluetooth (BT models), Wi-Fi (WF models) |
| Supported Symbologies | 1D: Code 128, UPC/EAN, Code 39, Interleaved 2 of 5, etc.; 2D: QR Code, Data Matrix, MaxiCode, Aztec, PDF417, etc. |
| Scan Engine | Area imager (2D) with aiming pattern |
| Operating Modes | Trigger, Presentation, Force, Level, Alternative, Flash, Toggle, Diagnostic |
| LED Indicators | Red, Green, Blue (programmable via serial command) |
| Beeper | Programmable tones (beep sequence up to 64 nodes) |
| Image Capture | Supported (A series): BMP, JPG, PNG, 8 or 32 bit |
| Bluetooth (on BT models) | Classic Bluetooth, up to 7 scanners per cradle (PICO mode) |
| Wi-Fi (on WF models) | 802.11 b/g/n, remote control and batch mode |
| Data Editing | DataWizard Premium (Data Script, Security Script) |
| Maintenance and Cleaning | Clean optics with soft, dry cloth; avoid solvents; store at 0–40°C, 5–95% RH |
| Safety | Laser Class 2 (typical); comply with local regulations |
| Spare Parts and Reparability | Contact Cino or authorized service for replacement cables, optics, housings |
| General Information | Cino FuzzyScan series; manual covers serial commands; software configurable; firmware upgradeable |
Frequently Asked Questions - F680 Cino
User questions about F680 Cino
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
Download the instructions for your Barcode Reader in PDF format for free! Find your manual F680 - Cino and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. F680 by Cino.
USER MANUAL F680 Cino
International Edition Rev.A5
Revision History
| Rev. 01 April 1, 2013 | ❖ Merged all the CMD Manuals of different series into one Manual❖ Added command TS A Operation Mode❖ Flash, Force, Toggle, and Diagnostic Mode in TS Operation Mode are available for L series from now on.❖ Change the parameter name of “Inverse Reading” to “1D Barcode Inverse Reading” inOperation❖ Added LED Illumination, Illumination Delay Duration inOperation.❖ Added Parameters forTS Operationincluding Operation Mode (Tethered A Series), Hand-Held Mode Illumination & Aiming Control, Hand-Free Mode Decode Aiming Control, Aiming Control, Delay Aiming Timeout, Presentation Background, Center Alignment, Mobile Phone Capture, Unique Barcode Reporting.❖ Modified parameter Code 128 Settings inSymbology❖ Added parameters forSymbology, including GS1-128, code 16k, code 49, QR code, Data Matrix, Maxicode, Aztec, Chinese Sensible, Australian post, US Planet, US Postnet, British post, Japan post, Netherlands KIX code, Intelligent mail. | |
| Rev. 02 August 16, 2013 | ❖ Added parameters forTransmission, including Data Script Active Setting, Data Script Setting, Security Script Setting and Data Wizard Premium Error Message.❖ AddedSecurity Check | |
| Rev. 03 March 25, 2014 | ❖ Added commandBT A Operation Mode❖ Added commandFS A Operation Mode❖ Added Auto Power Off Timeout and Bluetooth Device Name (Bluetooth A Series) inBluetooth❖ Added parameters forFS Operationand BT Operation, including Operation Mode (FA470 & SM5700 Series), Operation Mode (Bluetooth A Series), Hand-Held Mode Illumination & Aiming Control, Hand-Free Mode Decode Aiming Control, Aiming Control, Delay Aiming Timeout, Presentation Background Lighting, Center Alignment and Mobile Phone Capture. | |
| Rev. 04 April 25, 2014 | ❖ Page 2-17: Modified “LED Status” parameter inAction | |
| Rev. 05 June 3, 2014 | ❖ Page 1-4: ModifiedStatusdescription inCommand Structure | |
© Copyright Cino Group
© Copyright PC Worth Int'l Co., Ltd
Cino makes no warranty of any kind with regard to this publication, including, but not limited to, the implied warranty of merchantability and fitness for any particular purpose. Cino shall not be liable for errors contained herein or for incidental consequential damages in connection with the furnishing, performance, or use of this publication. This publication contains proprietary information that is protected by copyright. All rights are reserved. No part of this publication may be photocopied, reproduced or translated into any language, in any forms, in an electronic retrieval system or otherwise, without prior written permission of Cino. All product information and specifications shown in this document may be changed without prior notice.
Warranty
Cino warrants its products against defects in workmanship and materials from the date of shipment, provided that the product is operated under normal and proper conditions. The warranty provisions and durations are furnished by different warranty programs. The above warranty does not apply to any product which has been (i) misused; (ii) damaged by accident or negligence; (iii) modified or altered by the purchaser or other party; (iv) repaired or tampered by unauthorized representatives; (v) operated or stored beyond the specified operational and environmental parameters; (vi) applied software, accessories or parts are not supplied by Cino; (vii) damaged by circumstances out of Cino's control, such as, but not limited to, lightning or fluctuation in electrical power. Any defective product must follow the warranty program and RMA procedures to return Cino for inspection.
Table of Contents
About This Guide
Introduction
Chapter Descriptions
Notational Conventions
Related Documents
Command Overview 1-1
Command Briefing 1-2
Command Structure.... 1-4
Command Descriptions 2-1
Communication
Get Connected MAC, Reply Connected MAC (BT).... 2-2
Get Paired MAC, Reply Paired MAC(BT).... 2-4
Select By MAC, Deselect By MAC(BT).... 2-6
Select By ID, Deselect By ID(BT).... 2-8
Data
Decode Data (ALL).... 2-10
Transmit Record (ALL).... 2-11
Image
Enter Capture Image Mode (TS).... 2-12
Exit Capture Image Mode (TS).... 2-13
Capture Image Ready Notify (TS).... 2-14
Get Capture Image Data (TS).... 2-15
Action
LED Indicator (BT, TS).... 2-17
Beeping (ALL).... 2-18
Serial Trigger (ALL).... 2-19
Store Configuration (ALL) 2-20
Factory Default (ALL).... 2-21
Master Default (ALL).... 2-22
Security Check (ALL).... 2-23
BT Operation Mode (BT).... 2-24
BT A Operation Mode (BT).... 2-25
BT Synchronization (BT).... 2-26
FS Test Mode (FS).... 2-27
FS Operation Mode (FS).... 2-28
FS A Operation Mode (FS).... 2-29
SE Operation Mode (SE).... 2-30
TS Operation Mode (TS).... 2-31
TS A Operation Mode (TS).... 2-32
Paging (WF).... 2-33
Remote Indication (WF) 2-34
Remote Message (WF).... 2-36
Remote Clear (WF).... 2-38
Remote Lock (WF).... 2-40
Remote Unlock (WF).... 2-43
Remote Programming (WF).... 2-44
Remote Programming Extension (WF).... 2-45
Sync Date Time (WF).... 2-48
Delete Record (WF).... 2-49
Send Stern Data (WF).... 2-50
Interface
Corded Series
Set USB COM, Get USB COM, Reply USB COM (TS, SE, FM).... 2-51
Set RS232, Get RS232, Reply RS232 (TS, SE, FM).... 2-57
BT Scanner Series
Set USB COM, Get USB COM, Reply USB COM (BT).... 2-63
Set RS232, Get RS232, Reply RS232 (BT).... 2-69
Set Bluetooth, Get Bluetooth, Reply Bluetooth (BT) 2-75
Wi-Fi Scanner Series
Set USB HID, Get USB HID, Reply USB HID (WF).... 2-83
Set USB COM, Get USB COM, Reply USB COM (WF).... 2-89
Set Wi-Fi, Get Wi-Fi, Reply Wi-Fi (WF).... 2-95
Operation
Tether Scanner Series
Set TS Operation, Get TS Operation, Reply TS Operation (TS).... 2-101
Scan Engine Series
Set SE Operation, Get SE Operation, Reply SE Operation (SE)...... 2-115
Fixed-mount Scanner Series
Set FS Operation, Get FS Operation, Reply FS Operation (FS)...... 2-125
Bluetooth Scanner Series
Set BT Operation, Get BT Operation, Reply BT Operation (BT)...... 2-137
WiFi Scanner Series
Set WF Operation, Get WF Operation, Reply WF Operation (WF)...... 2-151
Set WF System, Get WF System, Reply WF System (WF).... 2-159
Set WF Scanning, Get WF Scanning, Reply WF Scanning (WF)...... 2-165
Transmission
Set Transmission, Get Transmission, Reply Transmission (ALL).... 2-173
Set Transmission, Get Transmission, Reply Transmission (WF)...... 2-181
Symbology
Set Symbology, Get Symbology, Reply Symbology (ALL).... 2-189
Device Info
Get Device Info, Reply Device Info (ALL).... 2-219
Get Record Count, Reply Record Count (ALL).... 2-223
Acknowledgement
Device ACK, Device NAK (ALL) 2-225
Host ACK, Host NAK (WF) 2-227
Host ACK Extension, Host NAK Extention (WF).... 2-229
Customer Support.... 3-1
About This Guide
Introduction
This guide provides complete programming information about the serial command of Cino FuzzyScan Scanner & OEM Engine, which enable Scanner to communicate with a serial host through a virtual COM port created.
Chapter Descriptions
Topics covered in this guide as follows:
Chapter 1 Command Overview
This chapter provides an overview of FuzzyScan Serial Command, including the command list, packet format and communication descriptions, etc.
Chapter2 Serial Command Descriptions
This chapter provides the detailed information of each serial command.
Notational Conventions
The following conventions are used in this document:
ALL: All FuzzyScan Series Scanners
SE: FuzzyScan Scan Engines
TS: FuzzyScan Tethered Scanners
FS: FuzzyScan Fixed-mount Scanners & Scan Module
BT: FuzzyScan Bluetooth Scanners
WF: FuzzyScan Wi-Fi Scanners
Related Documents
You may refer to following related documents to get more information:
■ FuzzyScan Scanner Integration Guide
■ FuzzyScan Scanner Programming Manual
■ FuzzyScan Scanner API Manual
If you need more information, please contact your supplier or visit our web site www.cino.com.tw.
Chapter 1 Command Overview
This chapter provides a comprehensive view of the FuzzyScan Serial Command, including:
- Command Briefing
- Command Structure
This will help programmer to understand the command structure and each key elements of FuzzyScan Serial Commands.
1.1 Command Briefing
The FuzzyScan Serial Commands provide a simple and effective way for serial host application to communicate with FuzzyScan device with ease. All commands have been categorized into several functional groups, including “Communication”, “Data”, “Image”, “Action”, “Interface”, “Operation”, “Transmission”, “Symbology”, “Device Info” and “Acknowledgement”. The following table shows all available commands for scanner.
In Action Group, there are ten special commands (Available for Wi-Fi L & F Series) which are used to remote control the scanner to display a user defined message, to beep, to vibrate, etc. Remote Control commands include Paging, Remote Indication, Remote Message, Remote Clear, Remote Lock, Remote Unlock, Remote Programming and Remote Programming Extension.
Important: For better use of Wi-Fi L & F Series Scanner, we introduced the concept of Programming Mode, which refers to an occasion where scanner is permitted to perform all the commands. However, Remote Control listed above is permitted on any occasion, which means scanner can only perform Remote Control when it is not in Programming mode. So if you want to set or get parameters to or from the scanner, you need to put it into Programming Mode using Remote Programming (Enter) or Remote Programming Extension (Enter) command. If not, the scanner will reject all the commands (except Remote Control) and replies a Device NAK. Once entered the Programming Mode, a lock message will be shown on the screen and the subsequent programming commands will all take effect. After the operation, you need to send Remote Programming (Exit) or Remote Programming Extension (Exit) to exit the mode.
| Functional Group | Command Name Supported Scanner | Message Source | |
| Communication | Get/Reply Connected MAC Bluetooth Scanners Host/Device | ||
| Get/Reply Paired MAC Bluetooth Scanners Host/Device | |||
| Select/Deselect By MAC Bluetooth Scanners Host/Host | |||
| Select/Deselect By ID Bluetooth Scanners Host/Host | |||
| Data | Decode Data All Series Scanners Host | ||
| Transmit Record Wi-Fi Scanners Host | |||
| Image | Enter Capture Image Mode Tethered Scanners | Host | |
| Exit Capture Image Mode | Tethered Scanners | Host | |
| Capture Image Ready Notify | Tethered Scanners | Host | |
| Get Capture Image Data Tethered Scanners Host | |||
| Action | LED Indicator Bluetooth, Tethered | Scanners | Host |
| Beeping All Series Scanners Host | |||
| Serial Trigger All Series Scanners | Host | ||
| Store Configuration All Series Scanners Host | |||
| Factory Default All Series Scanners Host | |||
| Master Default All Series Scanners Host | |||
| Security Check All Series Scanners Host | |||
| BT Operation Mode Bluetooth Scanners Host | |||
| BT Synchronize Bluetooth Scanners Host | |||
| FS Test Mode Fixed-mount Scanners Host | |||
| FS Operation Mode | Fixed-mount Scanners | Host | |
| SE Operation Mode | Scan Engines | Host | |
| TS Operation Mode | Tethered Scanners | Host | |
| TS A Operation Mode | Tethered Scanners | Host | |
| Paging | Wi-Fi Scanners | Host | |
| Remote Indication | Wi-Fi Scanners | Host | |
| Remote Message | Wi-Fi Scanners | Host | |
| Remote Clear Wi-Fi Scanners | Host | ||
| Remote Lock | Wi-Fi Scanners | Host | |
| Remote Unlock | Wi-Fi Scanners | Host | |
| Remote Programming | Wi-Fi Scanners | Host | |
| Remote Programming Extension | Wi-Fi Scanners | Host | |
| Sync Date Time Wi-Fi Scanners | Host | ||
| Delete Record | Wi-Fi Scanners | Host | |
| Interface | Set/ Get/ Reply USB COM | Host/Host/Device | |
| Set/ Get/ Reply RS232 | Host/Host/Device | ||
| Set/ Get/ Reply USB HID | Host/Host/Device | ||
| Set/ Get/ Reply Bluetooth | Bluetooth Scanners | Host/Host/Device | |
| Set/ Get/ Reply Wi-Fi | Wi-Fi Scanners | Host/Host/Device | |
| Operation | Set/ Get/ Reply TS Operation | Tethered Scanners | Host/Host/Device |
| Set/ Get/ Reply SE Operation | Scan Engines | Host/Host/Device | |
| Set/ Get/ Reply FS Operation | Fixed-mount Scanners | Host/Host/Device | |
| Set/ Get/ Reply BT Operation | Bluetooth Scanners | Host/Host/Device | |
| Set/ Get/ Reply WF Operation Wi-Fi Scanners Host/Host/Device | |||
| Set/ Get/ Reply WF System | Wi-Fi Scanners | Host/Host/Device | |
| Set/ Get/ Reply WF Scanning | Wi-Fi Scanners | Host/Host/Device | |
| Transmission | Set/ Get/ Reply Transmission | All Series Scanners | Host/Host/Device |
| Set/ Get/ Reply Transmission | Wi-Fi Scanners | Host/Host/Device | |
| Symbology | Set/ Get/ Reply Symbology | All Series Scanners | Host/Host/Device |
| Device Info | Get/ Reply Device Info | Wi-Fi Scanners | Host/Device |
| Get/ Reply Record Count | All Series Scanners | Host/Device | |
| Functional Group | Command Name Supported | Scanner Message Source | |
| Acknowledgement | Device ACK | All Series Scanners | Device |
| Device NAK | All Series Scanners | Device | |
| Host ACK | All Series Scanners | Host | |
| Host NAK | All Series Scanners | Host | |
| Host ACK Extension | Wi-Fi Scanners | Host | |
| Host ACK Extension | Wi-Fi Scanners | Host | |
1.2 Command Structure
Packet Format
The following table shows the general packet format of FuzzyScan Serial Command.
| Prefix | Opcode | Status | Length | Parameter(s) | Check Digit | Suffix | |
| 1 Byte | 3 | Bytes | 1 Byte | 2 Bytes | Variable | 1 Byte LRC or 2 Bytes CRC16 |
| Field Name Size Descriptions | ||
| Prefix | 1 Byte Fixed, “7Eh” | |
| Opcode | 3 Bytes | Operation code to identifies each command |
| Status | 1 Byte | Bit 2 ACK/NAK0 = Request1 = Do not requestBit 4 Check Digit0 = LRC (1 Byte)1 = CRC16 (2 Bytes) (See Notes)Bit 5 Continuation0 = Last packet1 = Intermediate packetOther BitsReserved. (Always 0) |
| Length | 2 Bytes | Total bytes amount of the Parameter(s) fieldFormatted as High Byte Low Byte.Length = Low Byte + High Byte x 256If Parameter(s) = null, Length = 00h, 00h. |
| Parameter(s) | Variable | See next paragraph |
| Check Digit | 1 Byte | LRC: “Opcode” XOR “Status” XOR “Length” XOR “Parameter(s)” |
| 2 Bytes | CRC16: From “Opcode” to “Parameter(s)” (See Notes) | |
| Suffix | 1 Byte Fixed, “7Eh” | |
.Notes
CRC16 Check Digit is only used in image command which is sent from scanner to host.
Command Overview
All FuzzyScan Serial Commands begin and end with the fixed prefix and suffix - 7Eh, which serve as parentheses. Between the prefix and the suffix is the command body. The main body consists of Opcode, Status, Length, Parameter(s) and check digit.
According to the functional group, there are two different parameter formats. The “Action” and “Acknowledgement” command groups use the “Simple” parameter format. The other command groups allow the “Compound” parameters to make more effective control. Please refer to the following paragraphs for details.
Escape Sequence
Several characters have special functions in FuzzyScan Serial Command and communication manipulation, such as "Prefix (7Eh)", "Suffix (7Eh)", "ACK (06h)", "NAK (15h)", "XON (11h)", "XOFF (13h)" and "Backslash (5Ch). If you have to use above characters in your command string (from "Length", "Parameter" to "LRC"), please replace them with their escaped value listed in following table.
| ASCII ~ \ | ACK NAK | XON XOFF | |||
| Hex | 7Eh | 5Ch | 06h | 15h | 11h |
| Escaped Value | 5Ch 00h | 5Ch 01h | 5Ch 02h | 5Ch 03h | 5Ch 04h |
For example,
If a host-to-device serial command is listed as below:
The "06h" have to be replaced "5Ch 02h". So the correct command string will be,
In other words, if the device send following string to host.
Your serial host application have to change "5Ch 02h" to "06h" as well.
Parameter Format
Generally, there are two different parameter formats, "Command with Simple Parameter(s)" and "Command with Compound Parameters".
Commands with simple parameters
The Action, Acknowledgement, Data and Image commands belong to this group.
1) Action
The parameter filed of Action commands can be "Null" or several option bytes. The following table shows the structure of Parameter(s) field:
| Parameter(s) | ||
| First byte of the parameter | ...... | Last byte of the parameter |
| Options ...... | Options | |
If the device successfully received the action command issued by the host, a "Device ACK" will be sent to the host right after the device performed the action. Otherwise, a "Device NAK" will be sent to host to issue a command error
If the host can't receive any reaction within the user preset time-out duration, this can be considered as a transmission failure. In this case, you are recommended to check the cable connection, power supply, setting of communication profile, and so on.
2) Acknowledgement command
There are four Acknowledge commands including “Device ACK”, “Device NAK”, “Host ACK” and “Host NAK”. All Acknowledgement commands have no parameters, it means the parameter field of those commands has to be set to “null”.
3) Data
The Decode Data is a special command, and it has to be considered as an unconditional event. If the "Data Transmission Packet" parameter is set to "Enable", the scanner will send a Packed Decode Data Message rather than a Raw Data message to the host after a successful decode. The actual decoded data will be put into the Parameter(s) field of Decode Data message string. Differently, the Transmit Record command is used to retrieve records from the scanner. Scanner send back the stored records as reply.
4) Image
Image commands is used to capture image, which is available for A series scanner. Enter/Exit Capture Image Mode formatted like Action command, scanner replies ACK/NAK. Capture Image Ready Notify is similar to Decode Data which is sent from the scanner to the host. And the format of Get Capture Image Data is like Transmit Record command, which is used to retrieve data from the scanner.
Commands with compound parameters
The Communication, Interface, Operation, Transmission, Symbology and Device Info commands belong to this group. For better understanding of the command format, we divide these commands into three types: Set, Get and Reply
1) Set
Set commands are used to configure the device setting. The parameter field can handle multiple parameters request at same time. It means you are able to change multiple setting of device at same as well. It is very useful for programmer to make fast initialization on the device.
Each parameter is composed of "PID", "Size" and "Option". If necessary, you are able to pack the selected parameters into one parameter field in accordance with the format described in the following table.
| Parameter(s) | ||||||
| First Parameter ... | Last Parameter | |||||
| PID Size Option | ... | PID Size Option | ||||
| 2 Bytes | 2 Byte | Variable | ... | 2 Bytes | 2 Byte | Variable |
| Size Descriptions | ||
| PID | 2 Byte Parameter ID | |
| Size | 2 Bytes Total bytes of the “Option” sectionFormatted as High Byte Low Byte.Length = Low Byte + High Byte x 256If Parameter(s) = null, Length = 00h, 00h.Operation code to identifies each command | |
| Options | Variable Parameter setting | |
Upon the receipt of a Set command, the scanner will response a Device ACK or Device NAK message to indicate whether the new settings has been performed successfully or not. If the host did not receive any response from the device within the user preset time-out duration, please resend the command.
2) Get
Get commands are used to obtain the device setting. The parameter field can handle multiple parameters request at the same time. It means you are able to obtain multiple settings of device at same as well. It is a very useful for application to reduce communication overhead.
Each parameter is composed of "PID", "Size" and "Option". If necessary, you are able to pack the selected parameters into one parameter field in accordance with the format described in the following table. Due to Get command does not have Option section, please always set the "Size" section to "00h 00h".
| Parameter(s) | ||||
| First Parameter | ... | Last Parameter | ||
| PID Size ... | PID Size | |||
| 2 Bytes | 2 Byte | 2 | Bytes | 2 Byte |
If the device received a Get command issued by the host successfully, the device will pack all requested parameters into one Reply message string and send it to the host. Otherwise, a Device NAK will be sent to host to indicate a command error. However, if the host didn't receive any response from the device within the user preset time-out duration, please resend the above command.
3) Reply
Reply message is sent by the device in response to the Get command. All the desired values are listed one by one in the Parameter(s) field in accordance with the format described in the following table. Each parameter is composed of "PID", "Size" and "Option". If necessary, you are able to pack the selected parameters into one parameter field in accordance with the format described in the following table. Please note that the Parameter(s) field of a Reply message is the same as Set command.
| Parameter(s) (Reply) | ||||||
| First Parameter | ... | Last Parameter | ||||
| PID Size | Option | ... | PID Size | Option | ||
| 2 Bytes | 2 Byte | Variable | ... | 2 Bytes | 2 Byte | Variable |
Since Reply message is a device-to-host return message, there is no response for this message.
Chapter 2 Command Descriptions
2.1 Communication
Get Connected MAC (BT)
Descriptions
Get the connected scanners' MAC addresses
This command is used when working with the SmartCradle in PICO mode.
Available for F, L & A series
Packet Format
| Prefix | Opcode | Status | Length | PID Size | LRC Suffix | |||
| 7Eh | D6h | FFh | FFh | 00h 00h | 04h | FFh 00h | 00h 00h | 2Dh 7Eh |
| 1 Byte | 3 Bytes | 1 Byte | 2 Bytes | 2 Bytes | 2 Bytes | 1 Byte 1 Byte | ||
. Host Requirements
If the device successfully received the above command issued by the host, a "Device ACK" will send to the host right after the device performed the action. Otherwise, a "Device NAK" will be sent to host to issue a command error. However, if the host can not receive any response from the device within the user preset time-out duration, please resend the above command.
. Length
Total size (bytes) of the Parameter(s) field
.LRC
"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"
. Size
Total size (bytes) of the Options field
Reply Connected MAC (BT)
Descriptions
List all the connected scanners' MAC addresses
Reply Connected MAC is sent by the device in response to the Get Connected MAC command.
Available for F, L & A series
Packet Format
| Prefix | Opcode | Status | Length | Parameter | LRC | Suffix | ||
| 7Eh | 17h | 00h | 00h Variable | (MAC List) | Variable | 7Eh | ||
| 1 Byte | 3 | Bytes | 1 Byte | 2 Bytes | Variable | 1 Byte | 1 Byte | |
. Host Requirements
If the device successfully received the above command issued by the host, a "Device ACK" will send to the host right after the device performed the action. Otherwise, a "Device NAK" will be sent to host to issue a command error. However, if the host can not receive any response from the device within the user preset time-out duration, please resend the above command.
. Length
Total size (bytes) of the Parameter(s) field
.LRC
"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"
. Size
Total size (bytes) of the Options field
Command Descriptions
Get Paired MAC (BT)
Descriptions
Get all the paired scanners' MAC addresses
This command is used when the working with the SmartCradle in PICO mode.
Available for F, L & A series
Packet Format
| Prefix | Opcode | Status | Length | PID | Size | LRC | Suffix | |||
| 7Eh | D6h | FFh | FFh | 00h | 00h | 04h | FFh 02h | 00h 00h | 2Fh 7Eh | |
| 1 Byte | 3 | Bytes | 1 Byte | 2 Bytes | 2 Bytes | 2 Bytes | 1 Byte 1 Byte | |||
. Host Requirements
If the device successfully received the above command issued by the host, a "Device ACK" will send to the host right after the device performed the action. Otherwise, a "Device NAK" will be sent to host to issue a command error. However, if the host can not receive any response from the device within the user preset time-out duration, please resend the above command.
. Length
Total size (bytes) of the Parameter(s) field
.LRC
"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"
. Size
Total size (bytes) of the Options field
Reply Paired MAC (BT)
Descriptions
List all the paired scanners' MAC addresses
Reply Paired MAC is sent by the device in response to the Get Paired MAC command.
Available for F, L & A series
Packet Format
| Prefix | Opcode | Status | Length | Parameter | LRC | Suffix | ||
| 7Eh | 17h | 00h | 00h Variable | (MAC List) | Variable | 7Eh | ||
| 1 Byte | 3 | Bytes | 1 Byte | 2 Bytes | 42 Bytes | 1 Byte | 1 Byte | |
. Host Requirements
If the device successfully received the above command issued by the host, a "Device ACK" will send to the host right after the device performed the action. Otherwise, a "Device NAK" will be sent to host to issue a command error. However, if the host can not receive any response from the device within the user preset time-out duration, please resend the above command.
. Parameter(s) Field
Since up to 7 scanners can be connected to one smart cradle concurrently, the Parameter field of the Reply Paired MAC takes 42 bytes. If there are less than 7 scanners paired, the rest bytes of the parameter field is filled with FFh.
. Length
Total size (bytes) of the Parameter(s) field
.LRC
"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"
. Size
Total size (bytes) of the Options field
Select By MAC (BT)
Descriptions
Use the MAC address to select the desired scanner to communicate
This command is useful when multiple scanners are connected to the SmartCradle in PICO mode. Select By MAC is often preceded by a Get Connected MAC command to provide a list from which the desired scanner will be selected. Afterwards, all the subsequent serial command will be send to this selected scanner, and the other scanners will not be able to communicate with the host until a Deselect By MAC command is sent.
Available for F, L & A series
Packet Format
| Prefix | Opcode | Status | Length | Parameter | LRC | Suffix | ||
| 7Eh | 95h | FFh | FFh | 00h 00h | 0Ah | See Below Variable | 7Eh | |
| 1 Byte | 3 | Bytes | 1 Byte | 2 Bytes | 10 Bytes | 1 Byte | 1 Byte | |
| Parameter | ||||||||
| First and the only Parameter | ||||||||
| PID Size | Options | |||||||
| FFh 00h | 00h 06h | (Scanner's MAC Address) | ||||||
| 2 Bytes | 2 Bytes | 6 Bytes | ||||||
. Host Requirements
If the device successfully received the above command issued by the host, a "Device ACK" will send to the host right after the device performed the action. Otherwise, a "Device NAK" will be sent to host to issue a command error. However, if the host can not receive any response from the device within the user preset time-out duration, please resend the above command.
. Length
Total size (bytes) of the Parameter(s) field
.LRC
"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"
. Size
Total size (bytes) of the Options field
Deselect By MAC (BT)
Descriptions
Deselect the scanner by MAC
This command is used to deselect the scanner which is selected by command Select By MAC. Please note that once this command is processed successfully, the host will be able to receive the decode data from all the connected scanners, but the subsequent serial commands sent will be neglected because there are not any selected scanner which is available to receive commands. Available for F, L & A series
Packet Format
| Prefix | Opcode | Status | Length | Parameter | LRC | Suffix | ||
| 7Eh | 95h | FFh | FFh | 00h 00h | 0Ah | See Below 66h | 7Eh | |
| 1 Byte | 3 | Bytes | 1 Byte | 2 Bytes | 10 Bytes | 1 Byte | 1 Byte |
. Host Requirements
If the device successfully received the above command issued by the host, a "Device ACK" will send to the host right after the device performed the action. Otherwise, a "Device NAK" will be sent to host to issue a command error. However, if the host can not receive any response from the device within the user preset time-out duration, please resend the above command.
. Length
Total size (bytes) of the Parameter(s) field
.LRC
"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"
. Size
Total size (bytes) of the Options field
Select By ID (BT)
Descriptions
Use the auto-assigned ID number to select the desired scanner to communicate
This command is useful when multiple scanners are connected to the SmartCradle in PICO mode. Afterwards, all the subsequent serial command will be send to this selected scanner, and the other scanners will not be able to communicate with the host until a Deselect By ID command is sent. Available for F, L & A series
Packet Format
| Prefix | Opcode | Status | Length | Parameter | LRC | Suffix | ||
| 7Eh | 95h | FFh | FFh | 00h 00h | 05h | See Below Variable | 7Eh | |
| 1 Byte | 3 | Bytes | 1 Byte | 2 Bytes | 5 Bytes | 1 Byte | 1 Byte | |
| Parameter | ||||||||
| First and the only Parameter | ||||||||
| PID Size | Options | |||||||
| FFh 01h | 00h 01h | (Scanner's ID) | ||||||
| 2 Bytes | 2 | Bytes | 1 Byte | |||||
. Host Requirements
If the device successfully received the above command issued by the host, a "Device ACK" will send to the host right after the device performed the action. Otherwise, a "Device NAK" will be sent to host to issue a command error. However, if the host can not receive any response from the device within the user preset time-out duration, please resend the above command.
. Length
Total size (bytes) of the Parameter(s) field
.LRC
"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"
. Size
Total size (bytes) of the Options field
Deselect By ID (BT)
Descriptions
Deselect the scanner by ID
This command is used to deselect the scanner which is selected by command Select By ID. Please note that once this command is processed successfully, the host will be able to receive the decode data from all the connected scanners, but the subsequent serial commands sent will be neglected because there are not any selected scanner which is available to receive commands. Available for F, L & A series
Packet Format
| Prefix | Opcode | Status | Length | Parameter | LRC | Suffix | |||
| 7Eh | 95h | FFh | FFh | 00h 00h | 05h | See Below | 6Fh | 7Eh | |
| 1 Byte | 3 | Bytes | 1 Byte | 2 Bytes | 5 Bytes | 1 Byte | 1 Byte | ||
| Parameter | |||||||||
| First and the only Parameter | |||||||||
| PID | Size | Options | |||||||
| FFh 01h | 00h 01h | 00h | |||||||
| 2 Bytes | 2 Bytes | 1 Byte | |||||||
. Host Requirements
If the device successfully received the above command issued by the host, a "Device ACK" will send to the host right after the device performed the action. Otherwise, a "Device NAK" will be sent to host to issue a command error. However, if the host can not receive any response from the device within the user preset time-out duration, please resend the above command.
. Length
Total size (bytes) of the Parameter(s) field
.LRC
"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"
. Size
Total size (bytes) of the Options field
2.2 Data
Decode Data (ALL)
Descriptions
Decoded Data in FSC packet format
Decode Data is considered as an unexpected event since the decoded data will be sent to the host whenever the scanner scanned a barcode, either accidentally or intentionally. The decoded data is sent in two types of format, either packed or unpacked. If packed data is selected, the scanner will send a packed Decode Data message rather than a Raw Data message to the host after a successful decode.
Packet Format
| Prefix | Opcode Status | Length | Parameter(s) | LRC Suffix | ||
| 7Eh | 14h 00h 00h | 00h Variable | Variable Variable | 7Eh | ||
| 1 Byte | 3 Bytes 1 Byte | 2 Bytes | Variable 1 Byte | 1 Byte | ||
. Host Requirements
Since Decode Data is a device-to-host message, there is no response for this message.
. Parameter(s) Field
The first 4 bytes indicates the Data Packet ID.
. Length
Total size (bytes) of the Parameter(s) field
.LRC
"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"
Transmit Record (WF)
Descriptions
Transmit all record(s) of Batch Mode
Available for F & L series
Packet Format
| Prefix | Opcode Status | Length | Parameter(s) | LRC Suffix | ||
| 7Eh | 80h 11h 01h | 00h 00h 00h | <Null> 90h 7Eh | |||
| 1 Byte | 3 Bytes 1 Byte 2 Bytes | 0 Byte 1 Byte 1 Byte | ||||
. Host Requirements
If the device successfully received the above command issued by the host, the device will reply the "Transmission Start Command" followed by the raw record data and the data transmission will end with the "Transmission End Command". Please refer to the following table for details. Otherwise, a "Device NAK" will be sent to host to indicate a command error. However, if the host can receive any response from the device within the user preset time-out duration, please resend the above command.
. Parameter(s) Field
Get Device Status can request multiple parameters at one time, so it takes compound parameters.
.LRC
"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"
. Size
Total size (bytes) of the Options field
Reply Format
● Part 1 – Transmission Start Command
| Prefix | Opcode Status | Length | Parameter(s) | LRC Suffix | ||
| 7Eh | 01h 02h 00h | 00h 00h 00h | <Null> 03h 7Eh | |||
| 1 Byte 3 | Bytes 1 Byte 2 Bytes | 0 Byte 1 Byte 1 Byte | ||||
- Part 2 – Raw Data
● Part 3 – Transmission End Command
| Prefix | Opcode Status | Length | Parameter(s) | LRC Suffix | ||
| 7Eh | 01h 02h 01h | 00h 00h 00h | <Null> 02h 7Eh | |||
| 1 Byte 3 | Bytes 1 Byte 2 Bytes | 0 Byte 1 Byte | 1 Byte | |||
2.3 Image
Enter Capture Image Mode (TS)
Descriptions
Enter Capture Image Mode
Once scanner is entered the Capture Image Mode, you can trigger the scanner to capture image repeatedly, after every image is captured and ready to be retrieved, scanner will send out a Capture Image Ready Notify packet to host, and then the host can send Get Capture Image Data command to retrieve the image data.
Available for A series
Packet Format
| Prefix | Opcode | Status | Length | Parameter(s) | LRC | Suffix | ||
| 7Eh | 80h | 1Ah 00h | 00h 00h | 0Ah | See below Variable | 7Eh | ||
| 1 Byte | 3 | Bytes | 1 Byte | 2 Bytes | 10 Bytes | 1 Byte | 1 Byte | |
. Host Requirements
If the device successfully received the above command issued by the host, a "Device ACK" will be sent to the host right after the device performed the action. Otherwise, a "Device NAK" will be sent to host to issue a command error. However, if the host can not receive any response from the device within the user preset time-out duration, please resend the above command.
.LRC
"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"
Parameter(s)
| Size | Parameter | Descriptions |
| 1 Byte | Type | - 00h Photo- 01h Video |
| 1 Byte | Format | - 00h 8 bits BMP- 01h 32 bits BMP- 02h JPG- 03h PNG |
| 1 Byte | Aimer | - 00h Without Aimer- 01h With Aimer |
| 1 Byte | AE | - 00h Fixed Exposure- 01h Auto Exposure |
| 2 Bytes (Big Endian) | Exp Level(The higher value the longer exposure time will be used) | - 0001h Level 1- 0002h Level 2- ......(Range from Level 1 ~ 24)- 0018h Level 24 |
| 4 Bytes | Timeout | Reserved (Always 00h) |
Exit Capture Image Mode (TS)
Descriptions
Exit Capture Image Mode
Available for A series
Packet Format
| Prefix | Opcode Status | Length | Parameter(s) | LRC Suffix | ||
| 7Eh | 80h 1Ah 01h | 00h 00h 00h | <NULL> 9B | 7Eh | ||
| 1 Byte 3 | Bytes 1 Byte 2 Bytes | 0 Byte 1 Byte | 1 Byte |
. Host Requirements
If the device successfully received the above command issued by the host, a "Device ACK" will be sent to the host right after the device performed the action. Otherwise, a "Device NAK" will be sent to host to issue a command error. However, if the host can not receive any response from the device within the user preset time-out duration, please resend the above command.
. Length
Total size (bytes) of the Parameter(s) field
.LRC
"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"
Capture Image Ready Notify (TS)
Descriptions
Capture image ready notify.
When an image is captured by scanner and ready to be retrieved by host, this command will be sent as a notification.
Available for A series
Packet Format
| Prefix | Opcode Status | Length | Parameter(s) | LRC Suffix | |
| 7Eh | 0Fh 1Ah 00h | 00h 00h 00h | 15 | 7Eh | |
| 1 Byte | 3 Bytes 1 Byte | 2 Bytes | 0 Byte 1 Byte | 1 Byte | |
. Host Requirements
Since Capture Image Ready Notify is a device-to-host message, there is no response for this message.
. Parameter(s) Field
Capture Image Ready Notify takes no parameters, so the Parameter(s) field is null.
. Length
Total size (bytes) of the Parameter(s) field
.LRC
"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"
Get Capture Image Data (TS)
Descriptions
Get the captured image data.
When in Capture Image mode, scanner stores the image of the last trigger automatically. This command is used to get the latest image data. On receiving this command, scanner will pack all the image data into several command packets and send back to the host (See Next Page).
Available for A series
Packet Format
| Prefix | Opcode Status | Length | Parameter(s) | LRC Suffix | ||
| 7Eh | 80h 1Ah 02h | 00h 00h 00h | <Null> 98 | 7Eh | ||
| 1 Byte | 3 Bytes 1 Byte | 2 Bytes | 0 Byte 1 Byte | 1 Byte | ||
. Host Requirements
If the device successfully received the above command issued by the host, the device will send an "Image Data Output" to the host. Please refer to the "Image Data Output" command for details. Otherwise, a "Device NAK" will be sent to host to indicate issue a command error. However, if the host can not receive any response from the device within the user preset time-out duration, please resend the above command.
. Length
Total size (bytes) of the Parameter(s) field
.LRC
"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"
. Size
Total size (bytes) of the Options field
Reply Format
● Part 1 – First Image Data Command
| Prefix | Opcode Status | Length Parameter | CRC16 | Suffix | |
| 7Eh | 0Fh 1Ah 02h | 34h 10h | 00h | See Below Variable | 7Eh |
| 1 Byte 3 | Bytes 1 Byte 2 | Bytes 4096 | Bytes 2 Bytes | 1 Byte |
● Part 2 – Subsequent Image Data Commands
| Prefix | Opcode Status | Length Parameter | CRC16 | Suffix | ||
| 7Eh | 0Fh 1Ah 02h | 34h 10h | 00h | Variable | 7Eh | |
| 1 Byte 3 | Bytes 1 Byte 2 | Bytes 4096 | Bytes 2 Bytes | 1 Byte | ||
● Part 3 – Last Image Data Command
| Prefix | Opcode | Status | Length | Parameter | CRC16 | Suffix |
| 7Eh | 0Fh 1Ah 02h | 14h See Note | Variable | 7Eh | ||
| 1 Byte | 3 Bytes | 1 Byte | 2 Bytes | Maximum 4096 Bytes | 2 Bytes | 1 Byte |
.Notes
- Status is defined as follows:
| Value | Bit 2 ACK/NAK | Bit 4 Check Digit | Bit 5 Continuation | Other Bits |
| 0 Do not request | LRC (1 Byte) | Last packet | Reserved | |
| 1 | Request | CRC16 (2 Bytes) | Intermediate packet | Always 0 |
- Length of the Last Image Data Command equals to the length of the remaining Image Data which should be no more than 4096 bytes.
- CRC16 Check Digit is calculated from the beginning of the Opcode field to the end of the Parameter field.
2.4 Action
LED Indicator (BT, TS)
Descriptions
Controls the LED indicators
This command turns on/off or restores one of the three LEDs, Red LED, Green LED, and Blue LED. Please note that LED Indicators can not be set to the default value by Factory Default or Master Default.
Available for Bluetooth F, L & A series and Tethered F, L & A series
Packet Format
| Prefix | Opcode Status | Length | Parameter(s) | LRC Suffix | ||
| 7Eh | 80h 00h 00h | 00h 00h 02h | See | Variable | 7Eh | |
| 1 Byte | 3 Bytes 1 Byte 2 Bytes | 1 Byte | 1 Byte 1 | Byte | ||
. Host Requirements
If the device successfully received the above command issued by the host, a "Device ACK" will be sent to the host right after the device performed the action. Otherwise, a "Device NAK" will be sent to host to issue a command error. However, if the host can not receive any response from the device within the user preset time-out duration, please resend the above command.
. Length
Total size (bytes) of the Parameter(s) field
.LRC
"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"
Parameter(s)
< Table 1-0 > LED Indicator Parameter(s) Field
| Parameter / PID / Size | Options | Descriptions |
| LED IndicatorPID :Size : 00h 02h (2 Bytes) | 1^st Byte- 01h- 02h- 03h 2^nd Byte- 00h- 01h- 02h | LED SelectionRed LEDGreen LEDBlue LEDLED StatusOFFONRestore to system control |
Beeping (ALL)
Descriptions
User programmable beeping control
Once received the Beeping command, the device will follow the desired beep sequence to sound the beeper.
Packet Format
| Prefix | Opcode Status | Length | Parameter(s) | LRC Suffix | ||
| 7Eh | 80h 01h 00h | 00h 00h 40h | See | Variable | 7Eh | |
| 1 Byte | 3 Bytes 1 Byte 2 Bytes | 64 Bytes 1 Byte | 1 Byte | |||
. Host Requirements
If the device successfully received the above command issued by the host, a "Device ACK" will be sent to the host right after the device performed the action. Otherwise, a "Device NAK" will be sent to host to issue a command error. However, if the host can not receive any response from the device within the user preset time-out duration, please resend the above command.
. Length
Total size (bytes) of the Parameter(s) field
.LRC
"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"
Parameter(s)
< Table 1-1 > Beeping Parameter(s) Field
| Parameter / PID / Size | Options | Descriptions |
| BeepingPID :Size : 00h 40h (64 Bytes) | 1^st 64^th ByteValue range:- 00h01h02h03h04h05h06h07h08h09h0Ah0Bh0Ch0Dh0Eh0Fh10hFFh | The 64-bytes parameter items specify 64 nodes respectively.The bigger the value, the lower it beeps.Duration of every node is fixed.10h serves as Suspension Node.The beep sequence is temporarily suspended when comes up against a Suspension Node.FFh serves as Termination Node.A beep sequence must end up with the Termination node FFh, otherwise a Device NAK will be sent to the host.The beep nodes following the termination node are indispensable but not part of the beep sequence. |
Serial Trigger (ALL)
Descriptions
Start or Stop a scan session
When triggered on, the scanner attempts to obtain the requested data. When triggered off, the scanner aborts a decode attempt.
Packet Format
| Prefix | Opcode Status | Length | Parameter(s) | LRC Suffix | ||
| 7Eh | 80h 02h 00h | 00h 00h 01h | See | Variable | 7Eh | |
| 1 Byte | 3 Bytes 1 Byte 2 Bytes | 1 Byte 1 Byte | 1 Byte | |||
. Host Requirements
If the device successfully received the above command issued by the host, a "Device ACK" will be sent to the host right after the device performed the action. Otherwise, a "Device NAK" will be sent to host to issue a command error. However, if the host can not receive any response from the device within the user preset time-out duration, please resend the above command.
. Length
Total size (bytes) of the Parameter(s) field
.LRC
"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"
Parameter(s)
< Table 1-2 > Serial Trigger Parameter(s) Field
| Parameter / PID / Size | Options | Descriptions |
| Serial TriggerPID :- 00hOFFSize : 00h 01h (1 Byte) - 01hON |
Store Configuration (ALL)
Descriptions
Save current settings into flash memory permanently
Note that this command is not available for storing the following settings: the beep sequence set by Beeping command; trigger status set by Serial Trigger command and LED status set by Indicator command.
Packet Format
| Prefix | Opcode Status | Length | Parameter(s) | LRC Suffix | |
| 7Eh | 80h 03h 00h | 00h 00h 00h | 83h | 7Eh | |
| 1 Byte | 3 Bytes 1 Byte | 2 Bytes | 0 Byte 1 Byte | 1 Byte | |
. Host Requirements
If the device successfully received the above command issued by the host, a "Device ACK" will be sent to the host right after the device performed the action. Otherwise, a "Device NAK" will be sent to host to issue a command error. However, if the host can not receive any response from the device within the user preset time-out duration, please resend the above command.
. Parameter(s) Field
Store Configuration command takes no parameters, so the Parameter(s) field is null.
. Length
Total size (bytes) of the Parameter(s) field
.LRC
"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"
Factory Default (ALL)
Descriptions
Set all parameters to the factory default
After sending this command, all parameters will be set to factory default value. Then the scanner resets all parameters into factory default values.
For Bluetooth L & F Series:
The radio link will be disconnected and the scanner will revert to uninstall state.
For Wi-Fi L & F Series:
Set all parameters to the factory default, except Fonts and Language Pack.
The radio link will be disconnected because Wi-Fi profiles are removed.
Packet Format
| Prefix | Opcode Status | Length | Parameter(s) | LRC Suffix | |
| 7Eh | 80h 04h 00h | 00h 00h 00h | <Null> 84h | 7Eh | |
| 1 Byte | 3 Bytes 1 Byte | 2 Bytes | 0 Byte 1 Byte | 1 Byte | |
. Host Requirements
Upon receiving this command, the device sends a "Device ACK" message immediately to the host before performs the action. Then it takes about 500 milliseconds to complete all jobs to reset all parameters into factory default values. Please note that you are not supposed to send any command during this period of time.
However, a “Device NAK” message is passed to the host to issue a command error. If the host can not receive any response from the device within the user preset time-out duration, please resend the above command.
. Parameter(s) Field
Factory Default command takes no parameters, so the Parameter(s) field is null.
. Length
Total size (bytes) of the Parameter(s) field
.LRC
"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"
Master Default (ALL)
Descriptions
Set all parameters to the factory default except for the interface settings
The host interface related parameters still remain the same after performing the Master Default command.
For Bluetooth L & F Series:
Set all parameters to the factory default settings except for the following parameters:
Handshaking Protocol, Baud Rate, Data Frame, Serial Response Timeout, Bluetooth Device Name, Bluetooth PIN Code, Out-of-range Scanning, Interface Delay Settings.
And the radio link is still on.
For Wi-Fi L & F Series:
Restore Scanner Settings and keep Fonts, Language Pack, Batch Records, Wi-Fi Profile, System Settings, Interface Settings, Online Scanning and Batch Scanning Settings.
And the radio link is still on.
Packet Format
| Prefix | Opcode Status | Length | Parameter(s) | LRC Suffix | |
| 7Eh | 80h 04h 01h | 00h 00h 00h | 85h | 7Eh | |
| 1 Byte | 3 Bytes 1 Byte | 2 Bytes | 0 Byte 1 Byte | 1 Byte | |
. Host Requirements
If the device successfully received the above command issued by the host, a "Device ACK" will be sent to the host right after the device performed the action. Otherwise, a "Device NAK" will be sent to host to issue a command error. However, if the host can not receive any response from the device within the user preset time-out duration, please resend the above command.
. Parameter(s) Field
Master Default command takes no parameters, so the Parameter(s) field is null.
. Length
Total size (bytes) of the Parameter(s) field
.LRC
"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"
Security Check (ALL)
Descriptions
Host sends this command to verify the connected scanner.
Once the scanner receives this command, it will pass the 16-byte parameter data to the Security Script to generate a 16-byte result data and send it back as a reply command to the host. If the Security Script is disabled, the reply would be a Device NAK.
This command is only available for Scanners that support DataWizard Premium. For more details about DataWizard Premium, please refer to FuzzyScan DataWizard Premium User Manual.
Packet Format
| Prefix | Opcode Status | Length | Parameter(s) | LRC Suffix | ||
| 7Eh | 80h 2Fh 00h | 00h 00h 10h | Variable Variable | 7Eh | ||
| 1 Byte | 3 Bytes 1 Byte 2 Bytes | 16 Bytes 1 Byte 1 Byte | ||||
. Host Requirements
If the security script does not exist or enabled, a "Device NAK" will be sent to the host. Otherwise, scanner will send back a Reply Command carrying the 16-byte result data (See Below). The host will check whether the result is right.
. Length
Total size (bytes) of the Parameter(s) field
.LRC
"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"
Reply Format
| Prefix | Opcode Status | Length | Parameter(s) | LRC Suffix | ||
| 7Eh | 0Fh 2Fh 00h | 00h 00h 10h | Variable Variable | 7Eh | ||
| 1 Byte | 3 Bytes 1 Byte 2 Bytes | 16 Bytes 1 Byte 1 Byte | ||||
BT Operation Mode (BT)
Descriptions
Select operation mode for Bluetooth Scanner
BT Operation Mode is equivalent to the Operation Mode Selection in the Set BT Operation command. It is of more convenience to use BT Operation Mode of the Action Command Category. Available for F & L series
Packet Format
| Prefix | Opcode Status | Length | Parameter(s) | LRC Suffix | ||
| 7Eh | 80h 08h 02h | 00h 00h 01h | See Below Variable | 7Eh | ||
| 1 Byte | 3 Bytes 1 Byte 2 Bytes | 1 Byte 1 Byte | 1 Byte | |||
. Host Requirements
If the device successfully received the above command issued by the host, a "Device ACK" will be sent to the host right after the device performed the action. Otherwise, a "Device NAK" will be sent to host to issue a command error. However, if the host can not receive any response from the device within the user preset time-out duration, please resend the above command.
. Length
Total size (bytes) of the Parameter(s) field
.LRC
"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"
Parameter(s)
< Table 4-1 > BT Operation Mode Parameter(s) Field
| Parameter / PID / Size | Options | Descriptions |
| BT Operation Mode | ||
| PID : | - 00h | Trigger mode (External triggering) * |
| Size : 00h 01h (1 Byte) | - 02h | Presentation mode (Auto Detection) |
BT A Operation Mode (BT)
Descriptions
Select operation mode for Bluetooth Scanner
BT A Operation Mode is equivalent to the Operation Mode Selection in the Set BT Operation command. It is of more convenience to use BT A Operation Mode of the Action Command Category. Available for A series
Packet Format
| Prefix | Opcode Status | Length | Parameter(s) | LRC Suffix | ||
| 7Eh | 80h 08h 05h | 00h 00h 03h | See Below Variable | 7Eh | ||
| 1 Byte | 3 Bytes 1 Byte 2 Bytes | 3 Bytes 1 Byte 1 Byte | ||||
. Host Requirements
If the device successfully received the above command issued by the host, a "Device ACK" will be sent to the host right after the device performed the action. Otherwise, a "Device NAK" will be sent to host to issue a command error. However, if the host can not receive any response from the device within the user preset time-out duration, please resend the above command.
. Length
Total size (bytes) of the Parameter(s) field
.LRC
"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"
Parameter(s)
< Table 4-6 > BT A Operation Mode Parameter(s) Field
| Parameter / PID / Size | Options | Descriptions |
| BT A Operation ModePID :Size : 00h 03h (3 Byte) | - 00h 01h 01h- 02h 01h 01h | Trigger mode *Presentation mode |
BT Synchronize (BT)
Descriptions
Synchronize BT scanner with SmartCradle
If the BT scanner(s) are working with the SmartCradle in PAIR mode or PICO mode, this command is used to sync the Scanner with the SmartCradle, so that the changes of the following six parameters will take effect instantly: "Handshaking Protocol", "Baud Rate", "Data Frame", "Serial Response Timeout", "Dollar Sign Control", "Field Delimiter" and "Data Transmission Packet". If not, the settings of the parameters described above will probably be neglected.
Note that if you are using the USB Virtual COM Port to connect the SmartCradle to the host, please close the virtual COM Port within 500 milliseconds right after you issue this command. Otherwise, the host can not identically detect the occupied COM Port after the synchronization.
Available for F, L & A series
Packet Format
| Prefix | Opcode Status | Length | Parameter(s) | LRC Suffix | ||
| 7Eh | 80h 09h 00h | 00h 00h 00h | <Null> 89h | 7Eh | ||
| 1 Byte | 3 Bytes 1 Byte | 2 Bytes | 0 Byte 1 Byte | 1 Byte | ||
. Host Requirements
If the device successfully received the above command issued by the host, a "Device ACK" will be sent to the host right after the device performed the action. Otherwise, a "Device NAK" will be sent to host to issue a command error. However, if the host can not receive any response from the device within the user preset time-out duration, please resend the above command.
. Parameter(s) Field
BT Synchronize command takes no parameters, so the Parameter(s) field is null.
. Length
Total size (bytes) of the Parameter(s) field
.LRC
"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"
FS Test Mode (FS)
Descriptions
Set the Fixed Mount and Scan Module to Test Mode.
You may refer to "FuzzyScan Fixed Mount Scanner Programming Manual" or "FuzzyScan Fixed Mount Scanner Quick Start Guide" for more details about the Test Mode.
Available for FM480, FA470, SM380 & SM5700 series
Packet Format
| Prefix | Opcode Status | Length | Parameter(s) | LRC Suffix | ||
| 7Eh | 80h 06h 00h | 00h 00h 01h | See Below Variable | 7Eh | ||
| 1 Byte | 3 Bytes 1 Byte 2 Bytes | 1 Byte 1 Byte | 1 Byte | |||
. Host Requirements
If the device successfully received the above command issued by the host, a "Device ACK" will be sent to the host right after the device performed the action. Otherwise, a "Device NAK" will be sent to host to issue a command error. However, if the host can not receive any response from the device within the user preset time-out duration, please resend the above command.
. Length
Total size (bytes) of the Parameter(s) field
.LRC
"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"
Parameter(s)
< Table 4-2 > FS Test Mode Parameter(s) Field
| Parameter / PID / Size | Options | Descriptions |
| FS Test Mode | ||
| PID : | - 00h | Fixed Reader Enter Test Mode 0 |
| Size : 00h 01h (1 Byte) | - 01h | Fixed Reader Enter Test Mode 1 |
FS Operation Mode (FS)
Descriptions
Select operation mode for Fixed Mount and Scan Module
FS Operation Mode is equivalent to the Operation Mode Selection in the Set FS Operation command. It is of more convenience to use FS Operation Mode of the Action Command Category. Available for FM480 & SM380 series
Packet Format
| Prefix | Opcode Status | Length | Parameter(s) | LRC Suffix | ||
| 7Eh | 80h 08h 03h | 00h 00h 01h | See Below Variable | 7Eh | ||
| 1 Byte | 3 Bytes 1 Byte 2 Bytes | 1 Byte 1 Byte | 1 Byte | |||
. Host Requirements
If the device successfully received the above command issued by the host, a "Device ACK" will be sent to the host right after the device performed the action. Otherwise, a "Device NAK" will be sent to host to issue a command error. However, if the host can not receive any response from the device within the user preset time-out duration, please resend the above command.
. Length
Total size (bytes) of the Parameter(s) field
.LRC
"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"
Parameter(s)
< Table 4-3 > FS Operation Mode Parameter(s) Field
| Parameter / PID / Size | Options | Descriptions |
| FS Operation Mode | ||
| PID : | - 00h | Trigger mode (External triggering) * |
| Size : 00h 01h (1 Byte) | - 01h | Force mode (Continued power on) |
| - 02h | Presentation mode (Auto Detection) | |
| - 04h | Level mode (Auto power off) | |
| - 06h | Alternative mode (Periodic power off) |
FS A Operation Mode (FS)
Descriptions
Select operation mode for Fixed Mount and Scan Module
FS A Operation Mode is equivalent to the Operation Mode Selection in the Set FS Operation command. It is of more convenience to use FS A Operation Mode of the Action Command Category. Available for FA470 & SM5700 series
Packet Format
| Prefix | Opcode Status | Length | Parameter(s) | LRC Suffix | ||
| 7Eh | 80h 08h 05h | 00h 00h 03h | See Below Variable | 7Eh | ||
| 1 Byte | 3 Bytes 1 Byte 2 Bytes | 3 Bytes 1 Byte 1 Byte | ||||
. Host Requirements
If the device successfully received the above command issued by the host, a "Device ACK" will be sent to the host right after the device performed the action. Otherwise, a "Device NAK" will be sent to host to issue a command error. However, if the host can not receive any response from the device within the user preset time-out duration, please resend the above command.
. Length
Total size (bytes) of the Parameter(s) field
.LRC
"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"
Parameter(s)
< Table 4-3 > FS A Operation Mode Parameter(s) Field
| Parameter / PID / Size | Options | Descriptions |
| FS A Operation ModePID :Size : 00h 03h (3 Byte) | - 00h 01h 01h- 01h 01h 01h- 02h 01h 01h- 04h 01h 00h- 06h 01h 00h | Trigger mode *Force modePresentation modeLevel modeAlternative mode |
SE Operation Mode (SE)
Descriptions
Select operation mode for Scan Engine
SE Operation Mode is equivalent to the Operation Mode Selection in the Set SE Operation command. It is of more convenience to use SE Operation Mode of the Action Command Category. Available for SE380, SE390 & SE480 series
Packet Format
| Prefix | Opcode Status | Length | Parameter(s) | LRC Suffix | ||
| 7Eh | 80h 08h 04h | 00h 00h 01h | See Below Variable | 7Eh | ||
| 1 Byte | 3 Bytes 1 Byte 2 Bytes | 1 Byte 1 Byte | 1 Byte | |||
. Host Requirements
If the device successfully received the above command issued by the host, a "Device ACK" will be sent to the host right after the device performed the action. Otherwise, a "Device NAK" will be sent to host to issue a command error. However, if the host can not receive any response from the device within the user preset time-out duration, please resend the above command.
. Length
Total size (bytes) of the Parameter(s) field
.LRC
"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"
Parameter(s)
< Table 4-4 > SE Operation Mode Parameter(s) Field
| Parameter / PID / Size | Options | Descriptions |
| SE Operation Mode | ||
| PID : | - 00h | Trigger mode (External triggering) * |
| - 01h | Force mode (Continued power on) (See Note) | |
| Size : 00h 01h (1 Byte) | - 02h | Presentation mode (Auto Detection) |
| - 04h | Level mode (Auto power off) | |
| - 06h | Alternative mode (Periodic power off) | |
| - 09h | Low Power mode (Low Power triggering) |
.Notes
Force mode is not available for SE390 and SE480 series.
TS Operation Mode (TS)
Descriptions
Select operation mode for Tethered Scanner
TS Operation Mode is equivalent to the Operation Mode Selection in the Set TS Operation command. It is of more convenience to use TS Operation Mode of the Action Command Category. Available for F & L series
Packet Format
| Prefix | Opcode Status | Length | Parameter(s) | LRC Suffix | ||
| 7Eh | 80h 08h 00h | 00h 00h 01h | See Below Variable | 7Eh | ||
| 1 Byte | 3 Bytes 1 Byte 2 Bytes | 1 Byte 1 Byte | 1 Byte | |||
. Host Requirements
If the device successfully received the above command issued by the host, a "Device ACK" will be sent to the host right after the device performed the action. Otherwise, a "Device NAK" will be sent to host to issue a command error. However, if the host can not receive any response from the device within the user preset time-out duration, please resend the above command.
. Length
Total size (bytes) of the Parameter(s) field
.LRC
"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"
Parameter(s)
< Table 4-5 > TS Operation Mode Parameter(s) Field
| Parameter / PID / Size | Options | Descriptions |
| TS Operation Mode | ||
| PID : | - 00h | Trigger mode (External triggering) * |
| Size : 00h 01h (1 Byte) | - 01h | Force mode (Continued power on) |
| - 02h | Presentation mode (Auto detection) | |
| - 04h | Level mode (Auto power off) | |
| - 05h | Diagnostic mode (Test reading) | |
| - 06h | Alternative mode (Periodic power off) | |
| - 07h | Toggle mode (Repeat reading) | |
| - 08h | Flash mode (Pulse driven reading) | |
| - 09h | Low Power mode (Low Power triggering) |
TS A Operation Mode (TS)
Descriptions
Select operation mode for Tethered A Series Scanner
TS A Operation Mode is equivalent to the Operation Mode Selection in the Set TS Operation command. It is of more convenience to use TS A Operation Mode of the Action Command Category. Available for A series
Packet Format
| Prefix | Opcode Status | Length | Parameter(s) | LRC Suffix | ||
| 7Eh | 80h 08h 05h | 00h 00h 03h | See Below Variable | 7Eh | ||
| 1 Byte | 3 Bytes 1 Byte 2 Bytes | 3 Bytes 1 Byte 1 Byte | ||||
. Host Requirements
If the device successfully received the above command issued by the host, a "Device ACK" will be sent to the host right after the device performed the action. Otherwise, a "Device NAK" will be sent to host to issue a command error. However, if the host can not receive any response from the device within the user preset time-out duration, please resend the above command.
. Length
Total size (bytes) of the Parameter(s) field
.LRC
"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"
Parameter(s)
< Table 4-6 > TS A Operation Mode Parameter(s) Field
| Parameter / PID / Size | Options | Descriptions |
| TS A Operation ModePID :Size : 00h 03h (3 Byte) | - 00h 01h 01h- 01h 01h 01h- 02h 01h 01h- 04h 01h 00h- 05h 01h 01h- 06h 01h 00h- 07h 01h 00h- 09h 01h 01h- 0Dh 01h 01h | Trigger mode *Force modePresentation modeLevel modeDiagnostic modeAlternative modeToggle modeLow Power modeMultiple mode |
Paging (WF)
Descriptions
Paging the scanner
This command is helpful for you to locate the connected Wi-Fi scanner.
Available for F & L series
Packet Format
| Prefix | Opcode Status | Length | Parameter(s) | LRC Suffix |
| 7Eh | 80h 90h 01h | 00h 00h 00h | 5Ch 04h 7Eh | |
| 1 Byte | 3 Bytes 1 Byte | 2 Bytes | 0 Byte 1 Byte | 1 Byte |
. Host Requirements
If the device successfully received the above command issued by the host, a “Device ACK” will be sent to the host right after the device performed the action. Otherwise, a “Device NAK” will be sent to host to issue a command error. However, if the host can not receive any response from the device within the user preset time-out duration, please resend the above command.
. Parameter(s) Field
Store Configuration command takes no parameters, so the Parameter(s) field is null.
. Length
Total size (bytes) of the Parameter(s) field
. LRC
"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"
Serial Command
Paging the scanner
0x7e 0x80 0x90 0x01 0x00 0x00 0x00 0x5c 0x04 0x7e
. Notes
0x5C 0x04: the escaped value of 0x11.
Remote Indication (WF)
Descriptions
Send remote indication to the connected scanner
Available for F & L series
Packet Format
| Prefix | Opcode | Status | Length | Parameter(s) | LRC | Suffix | ||
| 7Eh | 80h | 90h 02h | 00h 02h | 00h | See Next Page | Variable | 7Eh | |
| 1 Byte | 3 | Bytes | 1 Byte | 2 Bytes | 512 Bytes | 1 Byte | 1 Byte | |
. Host Requirements
If the device successfully received the above command issued by the host, a "Device ACK" will be sent to the host right after the device performed the action. Otherwise, a "Device NAK" will be sent to host to issue a command error. However, if the host can not receive any response from the device within the user preset time-out duration, please resend the above command.
. Length
Total size (bytes) of the Parameter(s) field
.LRC
"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"
Parameter(s)
| Size | Parameter Value | ||
| 2 Bytes | Code Page | 00h 00h | |
| 1 Byte | Close | 00h | |
| 1 Byte | Message Type | 07h | |
| 1 Byte | Bit 4~7 | Beeping Type | - 0h Short- 1h Long |
| Bit 0~3 | Number of Beep(s) | - 0h Disable- 1h Once- 2h 2 times- 3h 3 times- 5h 5 times- 8h 8 times- Ah 10 times | |
| 1 Byte | Bit 4~7 | Vibration Duration | - 1h 100ms- 2h 200ms- 3h 300ms- 4h 400ms- 5h 500ms |
| Bit 0~3 | Number of Vibration | - 0h Disable- 1h 1 time- 2h 2 times- 3h 3 times- 4h 4 times- 5h 5 times | |
| 3 Bytes | Message Length | 00h 00h 00h | |
| 503 Bytes | Message Content | 00h 00h ...00h | |
Remote Message (WF)
Descriptions
Send remote message to the connected scanner
Available for F & L series
Packet Format
| Prefix | Opcode | Status | Length | Parameter(s) | LRC | Suffix | ||
| 7Eh | 80h | 90h 02h | 00h 02h 00h | See Next Page | Variable | 7Eh | ||
| 1 Byte | 3 | Bytes | 1 Byte | 2 Bytes | 512 Bytes | 1 Byte | 1 Byte |
. Host Requirements
If the device successfully received the above command issued by the host, a "Device ACK" will be sent to the host right after the device performed the action. Otherwise, a "Device NAK" will be sent to host to issue a command error. However, if the host can not receive any response from the device within the user preset time-out duration, please resend the above command.
.Length
Total size (bytes) of the Parameter(s) field
.LRC
"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"
Parameter(s)
| Size | Parameter Value | ||
| 2 Bytes | Code Page | XXh XXh (See Notes) | |
| 1 Byte | Bit 7 | Manual Close | -0 Disable(See Notes)-1 Enable |
| Bit 0~6 | Auto Close | -0h Disable(See Notes)-3h after 3 seconds-5h after 5 seconds-8h after 8 seconds-Ah after 10 seconds | |
| 1 Byte | Bit 7~6 | Left Align | Set Bit 7 to 1, Bit 6 to 0 |
| Right Align | Set Bit 7 to 0, Bit 6 to 1 | ||
| Center Align | Set both Bit 7 and Bit 6 to 1 or 0 | ||
| Bit 5~0 | Message Type | -0h Tips-1h Warning-2h Question-3h Information-4h Error | |
| 1 Byte | Bit 4~7 | Beeping Type | -0h Short-1h Long |
| Bit 0~3 | Number of Beep | -0h Disable-1h Once-2h 2 times-3h 3 times-5h 5 times-8h 8 times-Ah 10 times | |
| 1 Byte | Bit 4~7 | Vibration Duration | -1h 100ms-2h 200ms-3h 300ms-4h 400ms-5h 500ms |
| Bit 0~3 | Number of Vibration | -0h Disable-1h 1 time-2h 2 times-3h 3 times-4h 4 times-5h 5 times | |
| 3 Bytes | Message Length | XXh XXh XXh (See Notes) | |
| 503 Bytes | Message Content | XXh... (See Notes) | |
.Notes
- The following Chart lists all available Code Pages and their 2-byte Hex value.
| 437 OEM - United States B5h 01h | |
| 737 OEM - Greek (formerly 437G) E1h 02h | |
| 850 OEM - Multilingual Latin I 52h 03h | |
| 852 OEM - Latin II 54h 03h | |
| 855 OEM - Cyrillic 57h 03h | |
| 857 OEM - Turkish 59h 03h | |
| 860 OEM - Portuguese 5Ch 03h | |
| 863 OEM - French Canadian 5Fh 03h | |
| 865 OEM - Nordic 61h 03h | |
| 866 OEM - Russian 62h 03h | |
| 932 ANSI/OEM Japanese (Shift-JIS) A4h 03h | |
| 936 ANSI/OEM - Simplified Chinese (GB2312) A8h 03h | |
| 950 ANSI/OEM - Traditional Chinese (Big5) B6h 03h | |
| 1250 ANSI - Central European | E2h 04h |
| 1251 ANSI - Cyrillic | E3h 04h |
| 1252 ANSI - Latin 1 | E4h 04h |
| 1253 ANSI - Greek | E5h 04h |
| 1254 ANSI - Turkish | E6h 04h |
| 1255 ANSI - Hebrew | E7h 04h |
- Manual Close and Auto Close can not be disabled at the same time.
- Message Length has at most three bytes. If the first byte is 0xFF, the following two bytes represent the content length, formatted as High Byte Low Byte. Otherwise, the first byte represents the content length itself, and the following two bytes will become part of the message content.
- Message Content uses Little-endian UCS-2 character set. If shorter than 503 bytes, the rest bytes should be set to 00h.
Command Descriptions
Remote Clear (WF)
Descriptions
Clear the remote message
The scanner will beep twice and vibrate for 100 milliseconds at the same time.
Available for F & L series
Packet Format
| Prefix | Opcode | Status | Length | Parameter(s) | LRC | Suffix | ||
| 7Eh | 80h | 90h 02h | 00h 02h | 00h | 00h 00h 00h00h 00h ... 00h | 08h | 18h | 7Eh |
| 1 Byte | 3 | Bytes | 1 Byte | 2 Bytes | 512 Bytes | 1 Byte | 1 Byte |
. Host Requirements
If the device successfully received the above command issued by the host, a "Device ACK" will be sent to the host right after the device performed the action. Otherwise, a "Device NAK" will be sent to host to issue a command error. However, if the host can not receive any response from the device within the user preset time-out duration, please resend the above command.
. Length
Total size (bytes) of the Parameter(s) field
.LRC
"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"
Remote Lock (WF)
Descriptions
Send remote message to the connected scanner
Note that a locked scanner can not work until the Remote Unlock is called.
Available for F & L series
Packet Format
| Prefix | Opcode | Status | Length | Parameter(s) | LRC | Suffix | ||
| 7Eh | 80h | 90h 02h | 00h 02h 00h | See Next Page Variable | 7Eh | |||
| 1 Byte | 3 | Bytes | 1 Byte | 2 Bytes | 512 Bytes | 1 Byte | 1 Byte | |
. Host Requirements
If the device successfully received the above command issued by the host, a "Device ACK" will be sent to the host right after the device performed the action. Otherwise, a "Device NAK" will be sent to host to issue a command error. However, if the host can not receive any response from the device within the user preset time-out duration, please resend the above command.
. Length
Total size (bytes) of the Parameter(s) field
.LRC
"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"
Parameter(s)
| Size | Parameter Value | ||
| 2 Bytes | Code Page | XXh XXh (See Notes) | |
| 1 Byte | Close | 00h | |
| 1 Byte | Bit 7~6 | Left Align | Set Bit 7 to 1, Bit 6 to 0 |
| Right Align | Set Bit 7 to 0, Bit 6 to 1 | ||
| Center Align | Set both Bit 7 and Bit 6 to 1 or 0 | ||
| Bit 5~0 | Message Type | -5h | |
| 1 Byte | Bit 4~7 | Beeping Type | -0h Short-1h Long |
| Bit 0~3 | Number of Beep | -0h Disable-1h Once-2h 2 times-3h 3 times-5h 5 times-8h 8 times-Ah 10 times | |
| 1 Byte | Bit 4~7 | Vibration Duration | -1h 100ms-2h 200ms-3h 300ms-4h 400ms-5h 500ms |
| Bit 0~3 | Number of Vibration | -0h Disable-1h 1 time-2h 2 times-3h 3 times-4h 4 times-5h 5 times | |
| 3 Bytes | Message Length | XXh XXh XXh (See Notes) | |
| 503 Bytes | Message Content | XXh... (See Notes) | |
.Notes
- The following Chart lists all available Code Pages and their 2-byte Hex value.
| 437 OEM - United States B5h 01h | |
| 737 OEM - Greek (formerly 437G) E1h 02h | |
| 850 OEM - Multilingual Latin I 52h 03h | |
| 852 OEM - Latin II 54h 03h | |
| 855 OEM - Cyrillic 57h 03h | |
| 857 OEM - Turkish 59h 03h | |
| 860 OEM - Portuguese 5Ch 03h | |
| 863 OEM - French Canadian 5Fh 03h | |
| 865 OEM - Nordic 61h 03h | |
| 866 OEM - Russian 62h 03h | |
| 932 ANSI/OEM Japanese (Shift-JIS) A4h 03h | |
| 936 ANSI/OEM - Simplified Chinese (GB2312) A8h 03h | |
| 950 ANSI/OEM - Traditional Chinese (Big5) B6h 03h | |
| 1250 ANSI - Central European | E2h 04h |
| 1251 ANSI - Cyrillic | E3h 04h |
| 1252 ANSI - Latin 1 | E4h 04h |
| 1253 ANSI - Greek | E5h 04h |
| 1254 ANSI - Turkish | E6h 04h |
| 1255 ANSI - Hebrew | E7h 04h |
- Manual Close and Auto Close can not be disabled at the same time.
- Message Length has at most three bytes. If the first byte is 0xFF, the following two bytes represent the content length, formatted as High Byte Low Byte. Otherwise, the first byte represents the content length itself, and the following two bytes will become part of the message content.
- Message Content uses Little-endian UCS-2 character set. If shorter than 503 bytes, the rest bytes should be set to 00h.
Remote Unlock (WF)
Descriptions
Send remote message to the connected scanner
The scanner will beep twice and vibrate for 100 milliseconds at the same time.
Available for F & L series
Packet Format
| Prefix | Opcode | Status | Length | Parameter(s) | LRC | Suffix | ||
| 7Eh | 80h | 90h 02h | 00h 02h | 00h | 00h 00h 5Ch02h | 00h 00h 00h 00h00h 00h ... 00h | 16h | 7Eh |
| 1 Byte | 3 | Bytes | 1 Byte | 2 Bytes | 513 Bytes | 1 Byte | 1 Byte |
. Host Requirements
If the device successfully received the above command issued by the host, a "Device ACK" will be sent to the host right after the device performed the action. Otherwise, a "Device NAK" will be sent to host to issue a command error. However, if the host can not receive any response from the device within the user preset time-out duration, please resend the above command.
. Length
Total size (bytes) of the Parameter(s) field
.LRC
"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"
.Notes
0x5C 0x02: the escaped value of 0x06.
Remote Programming (WF)
Descriptions
Enter or exit the Programming Mode.
Wi-Fi scanner can only perform Remote Control commands when it is not in Programming mode.
Remote Programming (Enter) is used to put scanner into programming mode, so that the subsequent programming commands will take effect. Please refer to Briefing Chapter (Page 1-2) for detailed descriptions. Note that in programming mode the scanner can not work until the Remote Programming (Exit) or Remote Programming Extension (Exit) is sent.
Available for F & L series
Packet Format
| Prefix | Opcode | Status | Length | Parameter(s) | LRC | Suffix | ||
| 7Eh | 80h | 90h 06h | 00h 00h 01h | See Below Variable | 7Eh | |||
| 1 Byte | 3 | Bytes | 1 Byte | 2 Bytes | 1 Byte | 1 Byte | 1 Byte | |
. Host Requirements
If the device successfully received the above command issued by the host, a "Device ACK" will be sent to the host right after the device performed the action. Otherwise, a "Device NAK" will be sent to host to issue a command error. However, if the host can not receive any response from the device within the user preset time-out duration, please resend the above command.
. Length
Total size (bytes) of the Parameter(s) field
.LRC
"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"
Parameter(s)
< Table 4-7 > Remote Programming Parameter(s) Field
| Parameter / PID / Size | Options | Descriptions |
| Remote ProgrammingPID :Size : 00h 01h (1 Byte) | - 00h- 01h | Exit Remote ProgrammingEnter Remote Programming |
Serial Command
Enter Remote Programming
Exit Remote Programming
Remote Programming Extension (WF)
Descriptions
Enter remote programming mode with user defined message, beeps and vibration.
Wi-Fi scanner can only perform Remote Control commands when it is not in Programming mode.
Remote Programming Extension (Enter) is used to put scanner into programming mode, so that the subsequent programming commands will take effect. Please refer to Briefing Chapter (Page 1-2) for detailed descriptions.
Note that in programming mode the scanner can not work until the Remote Programming (Exit) or Remote Programming Extension (Exit) is sent.
Available for F & L series
Packet Format
| Prefix | Opcode | Status | Length | Parameter(s) | LRC | Suffix | ||
| 7Eh | 80h | 90h 06h | 00h 02h 00h | See Next Page Variable | 7Eh | |||
| 1 Byte | 3 | Bytes | 1 Byte | 2 Bytes | 512 Bytes | 1 Byte | 1 Byte | |
. Host Requirements
If the device successfully received the above command issued by the host, a "Device ACK" will be sent to the host right after the device performed the action. Otherwise, a "Device NAK" will be sent to host to issue a command error. However, if the host can not receive any response from the device within the user preset time-out duration, please resend the above command.
. Length
Total size (bytes) of the Parameter(s) field
.LRC
"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"
Parameter(s)
| Size | Parameter Value | ||
| 2 Bytes | Code Page | XXh XXh (See Notes) | |
| 1 Byte | Bit 7 | Manual Close | -0 Disable (See Notes)-1 Enable |
| Bit 0~6 | Auto Close | -0h Disable (See Notes)-3h after 3 seconds-5h after 5 seconds-8h after 8 seconds-Ah after 10 seconds | |
| 1 Byte | Bit 7~6 | Left Align | Set Bit 7 to 1, Bit 6 to 0 |
| Right Align | Set Bit 7 to 0, Bit 6 to 1 | ||
| Center Align | Set both Bit 7 and Bit 6 to 1 or 0 | ||
| Bit 5~0 | Message Type - 0h Exit | Programming Mode-1h Enter Programming Mode | |
| 1 Byte | Bit 4~7 | Beeping Type | -0h Short-1h Long |
| Bit 0~3 | Number of Beep | -0h Disable-1h Once-2h 2 times-3h 3 times-5h 5 times-8h 8 times-Ah 10 times | |
| 1 Byte | Bit 4~7 | Vibration Duration | -1h 100ms-2h 200ms-3h 300ms-4h 400ms-5h 500ms |
| Bit 0~3 | Number of Vibration | -0h Disable-1h 1 time-2h 2 times-3h 3 times-4h 4 times-5h 5 times | |
| 3 Bytes | Message Length | XXh XXh XXh (See Notes) | |
| 503 Bytes | Message Content | XXh... (See Notes) | |
.Notes
- The following Chart lists all available Code Pages and their 2-byte Hex value.
| 437 OEM - United States B5h 01h | ||
| 737 OEM - Greek (formerly 437G) E1h 02h | ||
| 850 OEM - Multilingual Latin I 52h 03h | ||
| 852 OEM - Latin II 54h 03h | ||
| 855 OEM - Cyrillic 57h 03h | ||
| 857 OEM - Turkish | 59h | 03h |
| 860 OEM - Portuguese | 5Ch | 03h |
| 863 OEM - French Canadian | 5Fh | 03h |
| 865 OEM - Nordic | 61h | 03h |
| 866 OEM - Russian | 62h | 03h |
| 932 ANSI/OEM Japanese (Shift-JIS) | A4h | 03h |
| 936 ANSI/OEM - Simplified Chinese (GB2312) | A8h | 03h |
| 950 ANSI/OEM - Traditional Chinese (Big5) | B6h | 03h |
| 1250 | ANSI - Central European | E2h 04h |
| 1251 | ANSI - Cyrillic | E3h 04h |
| 1252 | ANSI - Latin 1 | E4h 04h |
| 1253 | ANSI - Greek | E5h 04h |
| 1254 | ANSI - Turkish | E6h 04h |
| 1255 | ANSI - Hebrew | E7h 04h |
- Manual Close and Auto Close can not be disabled at the same time. And they are available for Exit Programming Mode only.
- Message Length has at most three bytes. If the first byte is 0xFF, the following two bytes represent the content length, formatted as High Byte Low Byte. Otherwise, the first byte represents the content length itself, and the following two bytes will become part of the message content.
- Message Content uses Little-endian UCS-2 character set. If shorter than 503 bytes, the rest bytes should be set to 00h.
Sync Date Time (WF)
Descriptions
Set Date Time
Available for F & L series
Packet Format
| Prefix | Opcode Status | Length | Parameter(s) | LRC Suffix | ||
| 7Eh | 80h 30h 00h | 00h 00h 07h | See Below Variable | 7Eh | ||
| 1 Byte | 3 Bytes 1 Byte 2 Bytes | 7 Bytes 1 Byte 1 Byte | ||||
. Host Requirements
If the device successfully received the above command issued by the host, a "Device ACK" will be sent to the host right after the device performed the action. Otherwise, a "Device NAK" will be sent to host to issue a command error. However, if the host can not receive any response from the device within the user preset time-out duration, please resend the above command.
. Length
Total size (bytes) of the Parameter(s) field
.LRC
"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"
Parameter(s)
< Table 1-8 > Sync Date Time Parameter(s) Field
| Parameter / PID / Size | Options | Descriptions |
| Sync Date TimePID :Size : 00h 07h (7 Bytes) | 1^st 2^nd Byte- XXh XXh 3^rd Byte- XXh 4^th Byte- XXh 5^th Byte- XXh 6^th Byte- XXh 7^th Byte- XXh | Year(For example: 14h 0Ch stands for 2012)Month(See Notes)DayHourMinuteSecond |
.Notes
- Date Time values are described in Hex Value. For example, to set 16:13:03 Feb. 27, 2012, the parameter field should be: 14h 0Ch 02h 1Bh 10h 0Dh 03h.
Delete Record (WF)
Descriptions
Delete all record(s) of Batch Mode
Available for F & L series
Packet Format
| Prefix | Opcode Status | Length | Parameter(s) | LRC Suffix | ||
| 7Eh | 80h 11h 00h | 00h 00h 00h | <Null> 91h 7Eh | |||
| 1 Byte 3 | Bytes 1 Byte 2 Bytes | 0 Byte 1 Byte | 1 Byte | |||
. Host Requirements
If the device successfully received the above command issued by the host, a "Device ACK" will be sent to the host right after the device performed the action. Otherwise, a "Device NAK" will be sent to host to issue a command error. However, if the host can not receive any response from the device within the user preset time-out duration, please resend the above command.
. Length
Total size (bytes) of the Parameter(s) field
.LRC
"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"
Send STerm Data (WF)
Descriptions
This command is used to send Stern Page Data when works with WaveCentre.
It is sent by the host application to the WaveCentre.
Available for F & L series
Packet Format
| Prefix | Opcode Status | Length | Parameter(s) | LRC Suffix | ||
| 7Eh | 80h 80h 00h | 00h Variable | Variable Variable | 7Eh | ||
| 1 Byte | 3 Bytes 1 Byte 4 Bytes | Variable 1 Byte 1 Byte | ||||
. Host Requirements
There is no response for this message.
. Parameter
The Page Packet Body
. Length
Total size (bytes) of the Parameter(s) field
.LRC
"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"
2.5 Interface
Set USB COM (TS, SE, FM)
Descriptions
Change the desired one or more parameters of the USB COM Interface settings
Available for F, L & A series; SE380, SE390 & SE480 series; FM480 & SM380 series; FA470 & SM5700 Series
Packet Format
| Prefix | Opcode | Status | Length | Parameter(s) | LRC | Suffix | |||
| 7Eh | 82h | 00h | 03h | 00h | Variable | See Below | Variable | 7Eh | |
| 1 Byte | 3 | Bytes | 1 Byte | 2 Bytes | Variable | 1 Byte | 1 Byte | ||
| Parameter(s) | |||||||||
| First Parameter | ...... | Last Parameter | |||||||
| PID | Size | Options | ...... | PID | Size | Options | |||
| 2 Bytes | 2 Bytes | Variable | ...... | 2 Bytes | 2 Bytes | Variable | |||
| See Next Page | |||||||||
. Host Requirements
If the device successfully received the above command issued by the host, a "Device ACK" will send to the host right after the device performed the action. Otherwise, a "Device NAK" will be sent to host to issue a command error. However, if the host can not receive any response from the device within the user preset time-out duration, please resend the above command.
. Parameter(s) Field
Set USB COM can change multiple parameters at one time, so it takes compound parameters.
. Length
Total size (bytes) of the Parameter(s) field
.LRC
"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"
. Size
Total size (bytes) of the Options field
Parameter(s)
< Table 5-1-1 > Set USB COM Parameter(s) Field
| Parameter / PID / Size Options Descriptions | ||||
| STX/ETX TransmissionPID : 00h 00hSize : 00h 01h (1 Byte) | - 00h- 01h | Disable *Enable | ||
| Handshaking ProtocolPID : 00h 01hSize : 00h 03h (3 Bytes) | 1^st 3^rd Byte- 00h 00h 00h- 00h 00h 01h- 00h 01h 00h | None *ACK/NAKXon/Xoff | ||
| Baud RatePID : 00h 02hSize : 00h 01h (1 Byte) | - 02h- 03h- 04h- 05h | - 06h- 07h- 08h- 09h | 1200 BPS2400 BPS4800 BPS9600 BPS * | 19200 BPS38400 BPS57600 BPS115200 BPS |
| Data Frame(Data Bit, Parity, Stop Bit )PID : 00 03Size : 00h 01h (1 Byte) | - 02h- 05h- 08h | - 09h- 0Ah- 0Bh | 8, None, 1 *8, Even, 18, Odd, 1 | 8, None, 28, Space, 18, Mark, 1 |
| Serial Response Time-outPID : 00h 04hSize : 00h 01h (1 Byte) | - 01h- 04h- 09h- 0Fh- 12h- 24h- 4Fh- 50h- 48h- 56h- 5Ah- 61h | None200 ms500 ms *800 ms1 s2 s3 s4 s5 s8 s10 s15 s | ||
| ACK/NAK Retry CountPID : 00h 05hSize : 00h 01h (1 Byte) | - 03h- XXh | 3 times * (See Note)User-defined: XXh =desired seconds(h) | ||
| ACK/NAK IndicationPID : 00h 06hSize : 00h 01h (1 Byte) | Bit 0- 0- 1Bit 1 ~ 7 | ACK/NAK Transmission Fail IndicationDisableEnable *Reserved (Always 0) | ||
. Notes
ACK/NAK Retry Count ranges from 00h (never retry) to FFh (always retry).
Get USB COM (TS, SE, FM)
Descriptions
Request the desired one or more parameters of the USB COM Interface settings
Available for F, L & A series; SE380, SE390 & SE480 series; FM480 & SM380 series; FA470 & SM5700 Series
Packet Format
| Prefix | Opcode | Status | Length | Parameter(s) | LRC | Suffix | |||
| 7Eh | C3h 00h 03h | 00h | Variable | See Below Variable | 7Eh | ||||
| 1 Byte | 3 | Bytes | 1 Byte | 2 Bytes | Variable | 1 Byte | 1 Byte | ||
| Parameter(s) | |||||||||
| First Parameter | ...... | Last Parameter | |||||||
| PID Size | ...... | PID Size | |||||||
| 2 Bytes | 2 Bytes | ...... | 2 Bytes | 2 Bytes | |||||
| See Next Page | |||||||||
. Host Requirements
If the device successfully received the above command issued by the host, the device will pack all requested parameters into a "Reply USB COM" message string then send to the host. Please refer to the "Reply USB COM" command for details. Otherwise, a "Device NAK" will be sent to host to indicate issue a command error. However, if the host can receive any response from the device within the user preset time-out duration, please resend the above command.
. Parameter(s) Field
Get USB COM can request multiple parameters at one time, so it takes compound parameters.
. Length
Total size (bytes) of the Parameter(s) field
.LRC
"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"
. Size
Total size (bytes) of the Options field
Parameter(s)
< Table 5-1-2 > Get USB COM Parameter(s) Field
| Parameter PID Size | ||
| STX/ETX Transmission 00h 00h | 00h 00h | |
| Handshaking Protocol 00h 01h | 00h 00h | |
| Baud Rate 00h 02h | 00h 00h | |
| Data Frame 00h 03h | 00h 00h | |
| Serial Response Time-out 00h 04h | 00h 00h | |
| ACK/NAK Retry Count 00h 05h | 00h 00h | |
| ACK/NAK Indication 00h 06h | 00h 00h |
Reply USB COM (TS, SE, FM)
Descriptions
Reply the desired one or more parameters of the USB COM Interface settings
Reply USB COM is sent by the device in response to the Get USB COM command. It sends the values for all the desired parameters requested in the Get USB COM command.
Available for F, L & A series; SE380, SE390 & SE480 series; FM480 & SM380 series; FA470 & SM5700 Series
Packet Format
| Prefix | Opcode | Status | Length | Parameter(s) | LRC | Suffix | |||
| 7Eh | 04h | 00h | 03h | 00h | Variable | See Below Variable | 7Eh | ||
| 1 Byte | 3 Bytes | 1 Byte | 2 Bytes | Variable | 1 Byte | 1 Byte | |||
| Parameter(s) | |||||||||
| First Parameter | ...... | Last Parameter | |||||||
| PID | Size | Options | ...... | PID | Size | Options | |||
| 2 Bytes | 2 Bytes | Variable | ...... | 2 Bytes | 2 Bytes | Variable | |||
| See Next Page | |||||||||
| Parameter(s) | ||||||
| First Parameter | ...... | Last Parameter | ||||
| PID | Size | Options | ...... | PID | Size | Options |
| 2 Bytes | 2 Bytes | Variable | ...... | 2 Bytes | 2 Bytes | Variable |
| See Next Page | ||||||
. Host Requirements
Since Reply USB COM is a device-to-host message, there is no response for this message.
. Parameter(s) Field
Set USB COM can change multiple parameters at one time, so it takes compound parameters.
. Length
Total size (bytes) of the Parameter(s) field
.LRC
"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"
. Size
Total size (bytes) of the Options field
Parameter(s)
< Table 5-1-3 > Reply USB COM Parameter(s) Field
| Parameter / PID / Size Options Descriptions | ||||
| STX/ETX TransmissionPID : 00h 00hSize : 00h 01h (1 Byte) | - 00h- 01h | Disable *Enable | ||
| Handshaking ProtocolPID : 00h 01hSize : 00h 03h (3 Bytes) | 1^st 3^rd Byte- 00h 00h 00h- 00h 00h 01h- 00h 01h 00h | None *ACK/NAKXon/Xoff | ||
| Baud RatePID : 00h 02hSize : 00h 01h (1 Byte) | - 02h- 03h- 04h- 05h | - 06h- 07h- 08h- 09h | 1200 BPS2400 BPS4800 BPS9600 BPS * | 19200 BPS38400 BPS57600 BPS115200 BPS |
| Data Frame(Data Bit, Parity, Stop Bit )PID : 00 03Size : 00h 01h (1 Byte) | - 02h- 05h- 08h | - 09h- 0Ah- 0Bh | 8, None, 1 *8, Even, 18, Odd, 1 | 8, None, 28, Space, 18, Mark, 1 |
| Serial Response Time-outPID : 00h 04hSize : 00h 01h (1 Byte) | - 01h- 04h- 09h- 0Fh- 12h- 24h- 4Fh- 50h- 48h- 56h- 5Ah- 61h | None200 ms500 ms *800 ms1 s2 s3 s4 s5 s8 s10 s15 s | ||
| ACK/NAK Retry CountPID : 00h 05hSize : 00h 01h (1 Byte) | - 03h- XXh | 3 times * (See Note)User-defined: XXh =desired seconds(h) | ||
| ACK/NAK IndicationPID : 00h 06hSize : 00h 01h (1 Byte) | Bit 0- 0- 1Bit 1 ~ 7 | ACK/NAK Transmission Fail IndicationDisableEnable *Reserved (Always 0) | ||
.Notes
ACK/NAK Retry Count ranges from 00h (never retry) to FFh (always retry).
Set RS232 (TS, SE, FM)
Descriptions
Change the desired one or more parameters of the RS232 Interface settings
Available for F, L & A series; SE380, SE390 & SE480 series; FM480 & SM380 series; FA470 & SM5700 Series
Packet Format
| Prefix | Opcode | Status | Length | Parameter(s) | LRC | Suffix | |||
| 7Eh | 82h | 00h | 00h | Variable | See Below | Variable | 7Eh | ||
| 1 Byte | 3 | Bytes | 1 Byte | 2 Bytes | Variable | 1 Byte | 1 Byte | ||
| Parameter(s) | |||||||||
| First Parameter | ...... | Last Parameter | |||||||
| PID | Size | Options | ...... | PID | Size | Options | |||
| 2 Bytes | 2 Bytes | Variable | ...... | 2 Bytes | 2 Bytes | Variable | |||
| See Next Page | |||||||||
. Host Requirements
If the device successfully received the above command issued by the host, a "Device ACK" will send to the host right after the device performed the action. Otherwise, a "Device NAK" will be sent to host to issue a command error. However, if the host can not receive any response from the device within the user preset time-out duration, please resend the above command.
. Parameter(s) Field
Set RS232 command can change multiple parameters at one time, so it takes compound parameters.
. Length
Total size (bytes) of the Parameter(s) field
.LRC
"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"
. Size
Total size (bytes) of the Options field
Parameter(s)
< Table 5-2-1 > Set RS232 Parameter(s) Field
| Parameter / PID / Size Options Descriptions | ||||
| STX/ETX TransmissionPID : 00h 00hSize : 00h 01h (1 Byte) | - 00h- 01h | Disable *Enable | ||
| Handshaking ProtocolPID : 00h 01hSize : 00h 03h (3 Bytes) | 1^st 3^rd Byte- 00h 00h 00h- 01h 00h 00h- 00h 00h 01h- 00h 01h 00h | None *RTS/CTSACK/NAKXon/Xoff | ||
| Baud RatePID : 00h 02hSize : 00h 01h (1 Byte) | - 02h- 03h- 04h- 05h | - 06h- 07h- 08h- 09h | 1200 BPS2400 BPS4800 BPS9600 BPS * | 19200 BPS38400 BPS57600 BPS115200 BPS |
| Data Frame(Data Bit, Parity, Stop Bit )PID : 00 03Size : 00h 01h (1 Byte) | - 02h- 05h- 08h | - 09h- 0Ah- 0Bh | 8, None, 1 *8, Even, 18, Odd, 1 | 8, None, 28, Space, 18, Mark, 1 |
| Serial Response Time-outPID : 00h 04hSize : 00h 01h (1 Byte) | - 01h- 04h- 09h- 0Fh- 12h- 24h- 4Fh- 50h- 48h- 56h- 5Ah- 61h | None200 ms500 ms *800 ms1 s2 s3 s4 s5 s8 s10 s15 s | ||
| ACK/NAK Retry CountPID : 00h 05hSize : 00h 01h (1 Byte) | - 03h- XXh | 3 times * (See Note)User-defined: XXh =desired seconds(h) | ||
| ACK/NAK IndicationPID : 00h 06hSize : 00h 01h (1 Byte) | Bit 0- 0- 1Bit 1 ~ 7 | ACK/NAK Transmission Fail IndicationDisableEnable *Reserved (Always 0) | ||
Notes
ACK/NAK Retry Count ranges from 00h (never retry) to FFh (always retry).
Get RS232 (TS, SE, FM)
Descriptions
Request the desired one or more parameters of the RS232 Interface settings
Available for F, L & A series; SE380, SE390 & SE480 series; FM480 & SM380 series; FA470 & SM5700 Series
Packet Format
| Prefix | Opcode | Status | Length | Parameter(s) | LRC | Suffix | |||
| 7Eh | C3h | 00h | 00h | Variable | See Below | Variable | 7Eh | ||
| 1 Byte | 3 | Bytes | 1 Byte | 2 Bytes | Variable | 1 Byte | 1 Byte | ||
| Parameter(s) | |||||||||
| First Parameter | ...... | Last Parameter | |||||||
| PID Size | ...... | PID Size | |||||||
| 2 Bytes | 2 Bytes | ...... | 2 Bytes | 2 Bytes | |||||
| See Next Page | |||||||||
. Host Requirements
If the device successfully received the above command issued by the host, the device will pack all requested parameters into a "Reply RS232" message string then send to the host. Please refer to the "Reply RS232" command for details. Otherwise, a "Device NAK" will be sent to host to indicate issue a command error. However, if the host can receive any response from the device within the user preset time-out duration, please resend the above command.
. Parameter(s) Field
Get RS232 command can request multiple parameters at one time, so it takes compound parameters.
. Length
Total size (bytes) of the Parameter(s) field
.LRC
"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"
. Size
Total size (bytes) of the Options field
Parameter(s)
< Table 5-2-2 > Get RS232 Parameter(s) Field
| Parameter PID Size | ||
| STX/ETX Transmission 00h 00h | 00h 00h | |
| Handshaking Protocol 00h 01h | 00h 00h | |
| Baud Rate 00h 02h | 00h 00h | |
| Data Frame 00h 03h | 00h 00h | |
| Serial Response Time-out 00h 04h | 00h 00h | |
| ACK/NAK Retry Count 00h 05h | 00h 00h | |
| ACK/NAK Indication 00h 06h | 00h 00h |
Reply RS232 (TS, SE, FM)
Descriptions
Reply RS232 Interface Settings
Reply RS232 is sent by the device in response to the Get RS232 command. It sends the values for all the desired parameters requested in the Get RS232 command.
Available for F, L & A series; SE380, SE390 & SE480 series; FM480 & SM380 series; FA470 & SM5700 Series
Packet Format
| Prefix | Opcode | Status | Length | Parameter(s) | LRC | Suffix | |||
| 7Eh | 04h | 00h | 00h | Variable | See Below | Variable | 7Eh | ||
| 1 Byte | 3 | Bytes | 1 Byte | 2 Bytes | Variable | 1 Byte | 1 Byte | ||
| Parameter(s) | |||||||||
| First Parameter | ...... | Last Parameter | |||||||
| PID | Size | Options | ...... | PID | Size | Options | |||
| 2 Bytes | 2 Bytes | Variable | ...... | 2 Bytes | 2 Bytes | Variable | |||
| See Next Page | |||||||||
. Host Requirements
Since Reply RS232 is a device-to-host message, there is no response for this message.
. Parameter(s) Field
Set RS232 command can change multiple parameters at one time, so it takes compound parameters.
. Length
Total size (bytes) of the Parameter(s) field
.LRC
"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"
. Size
Total size (bytes) of the Options field
Parameter(s)
< Table 5-2-3 > Reply RS232 Parameter(s) Field
| Parameter / PID / Size Options Descriptions | ||||
| STX/ETX TransmissionPID : 00h 00hSize : 00h 01h (1 Byte) | - 00h- 01h | Disable *Enable | ||
| Handshaking ProtocolPID : 00h 01hSize : 00h 03h (3 Bytes) | 1^st 3^rd Byte- 00h 00h 00h- 01h 00h 00h- 00h 00h 01h- 00h 01h 00h | None *RTS/CTSACK/NAKXon/Xoff | ||
| Baud RatePID : 00h 02hSize : 00h 01h (1 Byte) | - 02h- 03h- 04h- 05h | - 06h- 07h- 08h- 09h | 1200 BPS2400 BPS4800 BPS9600 BPS * | 19200 BPS38400 BPS57600 BPS115200 BPS |
| Data Frame(Data Bit, Parity, Stop Bit )PID : 00 03Size : 00h 01h (1 Byte) | - 02h- 05h- 08h | - 09h- 0Ah- 0Bh | 8, None, 1 *8, Even, 18, Odd, 1 | 8, None, 28, Space, 18, Mark, 1 |
| Serial Response Time-outPID : 00h 04hSize : 00h 01h (1 Byte) | - 01h- 04h- 09h- 0Fh- 12h- 24h- 4Fh- 50h- 48h- 56h- 5Ah- 61h | None200 ms500 ms *800 ms1 s2 s3 s4 s5 s8 s10 s15 s | ||
| ACK/NAK Retry CountPID : 00h 05hSize : 00h 01h (1 Byte) | - 03h- XXh | 3 times * (See Note)User-defined: XXh =desired seconds(h) | ||
| ACK/NAK IndicationPID : 00h 06hSize : 00h 01h (1 Byte) | Bit 0- 0- 1Bit 1 ~ 7 | ACK/NAK Transmission Fail IndicationDisableEnable *Reserved (Always 0) | ||
.Notes
ACK/NAK Retry Count ranges from 00h (never retry) to FFh (always retry).
Command Descriptions
Set USB COM (BT)
Descriptions
Change the desired one or more parameters of the USB COM Interface settings
Available for F, L & A series
Packet Format
| Prefix | Opcode | Status | Length | Parameter(s) | LRC | Suffix | ||
| 7Eh | 82h | 00h | 03h | 00h | Variable | See Below | Variable | 7Eh |
| 1 Byte | 3 | Bytes | 1 Byte | 2 Bytes | / | Variable 1 Byte | 1 Byte |
| Parameter(s) | ||||||
| First Parameter | ...... | Last Parameter | ||||
| PID | Size | Options | ...... | PID | Size | Options |
| 2 Bytes | 2 Bytes | Variable | ...... | 2 Bytes | 2 Bytes | Variable |
| See Next Page | ||||||
. Host Requirements
If the device successfully received the above command issued by the host, a "Device ACK" will send to the host right after the device performed the action. Otherwise, a "Device NAK" will be sent to host to issue a command error. However, if the host can not receive any response from the device within the user preset time-out duration, please resend the above command.
. Parameter(s) Field
Set USB COM can change multiple parameters at one time, so it takes compound parameters.
. Length
Total size (bytes) of the Parameter(s) field
.LRC
"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"
. Size
Total size (bytes) of the Options field
Parameter(s)
< Table 5-3-1 > Set USB COM Parameter(s) Field
| Parameter / PID / Size Options Descriptions | ||||
| STX/ETX TransmissionPID : 00h 00hSize : 00h 01h (1 Byte) | - 00h- 01h | Disable *Enable | ||
| Baud RatePID : 00h 02hSize : 00h 01h (1 Byte) | - 02h- 03h- 04h- 05h | - 06h- 07h- 08h- 09h | 1200 BPS2400 BPS4800 BPS9600 BPS * | 19200 BPS38400 BPS57600 BPS115200 BPS |
| Data Frame(Data Bit, Parity, Stop Bit )PID : 00 03Size : 00h 01h (1 Byte) | - 02h- 08h- 05h- 0Ah- 0Bh- 09h- 06h- 03h | - 0Ch- 0Dh- 01h- 07h- 04h- 0Eh- 0Fh | 8, None, 1 *8, Odd, 18, Even, 18, Space, 18, Mark, 18, None, 27, Odd, 17, Even, 1 | 7, Space, 17, Mark, 17, None, 27, Odd, 27, Even, 27, Space, 27, Mark, 2 |
Get USB COM (BT)
Descriptions
Request the desired one or more parameters of the USB COM Interface settings
Available for F, L & A series
Packet Format
| Prefix | Opcode | Status | Length | Parameter(s) | LRC | Suffix | |||
| 7Eh | C3h | 00h | 03h | 00h | Variable | See Below | Variable | 7Eh | |
| 1 Byte | 3 | Bytes | 1 Byte | 2 Bytes | Variable | 1 Byte | 1 Byte | ||
| Parameter(s) | |||||||||
| First Parameter | ...... | Last Parameter | |||||||
| PID Size ...... | PID Size | ||||||||
| 2 Bytes | 2 Bytes | ...... | 2 Bytes | 2 Bytes | |||||
| See Next Page | |||||||||
. Host Requirements
If the device successfully received the above command issued by the host, the device will pack all requested parameters into a "Reply USB COM" message string then send to the host. Please refer to the "Reply USB COM" command for details. Otherwise, a "Device NAK" will be sent to host to indicate issue a command error. However, if the host can receive any response from the device within the user preset time-out duration, please resend the above command.
. Parameter(s) Field
Get USB COM can request multiple parameters at one time, so it takes compound parameters.
. Length
Total size (bytes) of the Parameter(s) field
.LRC
"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"
. Size
Total size (bytes) of the Options field
Parameter(s)
< Table 5-3-2 > Get USB COM Parameter(s) Field
| Parameter PID Size | ||
| STX/ETX Transmission 00h 00h | 00h 00h | |
| Baud Rate 00h 02h | 00h 00h | |
| Data Frame 00h 03h | 00h 00h |
Reply USB COM (BT)
Descriptions
Reply the desired one or more parameters of the USB COM Interface settings
Reply USB COM is sent by the device in response to the Get USB COM command. It sends the values for all the desired parameters requested in the Get USB COM command.
Available for F, L & A series
Packet Format
| Prefix | Opcode | Status | Length | Parameter(s) | LRC | Suffix | ||
| 7Eh | 04h | 00h | 03h | 00h | Variable | See Below Variable | 7Eh | |
| 1 Byte | 3 | Bytes | 1 Byte | 2 Bytes | / | Variable | 1 Byte | |
| Parameter(s) | ||||||
| First Parameter | ...... | Last Parameter | ||||
| PID | Size | Options | ...... | PID | Size | Options |
| 2 Bytes | 2 Bytes | Variable | ...... | 2 Bytes | 2 Bytes | Variable |
| See Next Page | ||||||
. Host Requirements
Since Reply USB COM is a device-to-host message, there is no response for this message.
. Parameter(s) Field
Set USB COM can change multiple parameters at one time, so it takes compound parameters.
. Length
Total size (bytes) of the Parameter(s) field
.LRC
"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"
. Size
Total size (bytes) of the Options field
Parameter(s)
< Table 5-3-3 > Reply USB COM Parameter(s) Field
| Parameter / PID / Size Options Descriptions | ||||
| STX/ETX TransmissionPID : 00h 00hSize : 00h 01h (1 Byte) | - 00h- 01h | Disable *Enable | ||
| Baud RatePID : 00h 02hSize : 00h 01h (1 Byte) | - 02h- 03h- 04h- 05h | - 06h- 07h- 08h- 09h | 1200 BPS2400 BPS4800 BPS9600 BPS * | 19200 BPS38400 BPS57600 BPS115200 BPS |
| Data Frame(Data Bit, Parity, Stop Bit )PID : 00 03Size : 00h 01h (1 Byte) | - 02h- 08h- 05h- 0Ah- 0Bh- 09h- 06h- 03h | - 0Ch- 0Dh- 01h- 07h- 04h- 0Eh- 0Fh | 8, None, 1 *8, Odd, 18, Even, 18, Space, 18, Mark, 18, None, 27, Odd, 17, Even, 1 | 7, Space, 17, Mark, 17, None, 27, Odd, 27, Even, 27, Space, 27, Mark, 2 |
Set RS232 (BT)
Descriptions
Change the desired one or more parameters of the RS232 Interface settings
Available for F, L & A series
Packet Format
| Prefix | Opcode | Status | Length | Parameter(s) | LRC | Suffix | ||
| 7Eh | 82h | 00h | 00h | Variable | See Below Variable | 7Eh | ||
| 1 Byte | 3 | Bytes | 1 Byte | 2 Bytes | Variable | 1 Byte | 1 Byte | |
| Parameter(s) | ||||||
| First Parameter | ...... | Last Parameter | ||||
| PID | Size | Options | ...... | PID | Size | Options |
| 2 Bytes | 2 Bytes | Variable | ...... | 2 Bytes | 2 Bytes | Variable |
| See Next Page | ||||||
. Host Requirements
If the device successfully received the above command issued by the host, a "Device ACK" will send to the host right after the device performed the action. Otherwise, a "Device NAK" will be sent to host to issue a command error. However, if the host can not receive any response from the device within the user preset time-out duration, please resend the above command.
. Parameter(s) Field
Set RS232 command can change multiple parameters at one time, so it takes compound parameters.
. Length
Total size (bytes) of the Parameter(s) field
.LRC
"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"
. Size
Total size (bytes) of the Options field
Parameter(s)
< Table 5-4-1 > Set RS232 Parameter(s) Field
| Parameter / PID / Size Options Descriptions | ||||
| STX/ETX TransmissionPID : 00h 00hSize : 00h 01h (1 Byte) | - 00h- 01h | Disable *Enable | ||
| Handshaking ProtocolPID : 00h 01hSize : 00h 03h (3 Bytes) | 1^st 3^rd Byte- 00h 00h 00h- 01h 00h 00h- 00h 00h 01h- 00h 01h 00h | None *RTS/CTSACK/NAKXon/Xoff | ||
| Baud RatePID : 00h 02hSize : 00h 01h (1 Byte) | - 02h- 03h- 04h- 05h | - 06h- 07h- 08h- 09h | 1200 BPS2400 BPS4800 BPS9600 BPS * | 19200 BPS38400 BPS57600 BPS115200 BPS |
| Data Frame(Data Bit, Parity, Stop Bit )PID : 00 03Size : 00h 01h (1 Byte) | - 02h- 05h- 08h | - 09h- 0Ah- 0Bh | 8, None, 1 *8, Even, 18, Odd, 1 | 8, None, 28, Space, 18, Mark, 1 |
| Serial Response Time-outPID : 00h 04hSize : 00h 01h (1 Byte) | - 01h- 04h- 09h- 0Fh- 12h- 24h- 4Fh- 50h- 48h- 56h- 5Ah- 61h | None200 ms500 ms *800 ms1 s2 s3 s4 s5 s8 s10 s15 s | ||
| ACK/NAK Retry CountPID : 00h 05hSize : 00h 01h (1 Byte) | - 03h- XXh | 3 times * (See Note)User-defined: XXh =desired seconds(h) | ||
| ACK/NAK IndicationPID : 00h 06hSize : 00h 01h (1 Byte) | Bit 0- 0- 1Bit 1 ~ 7 | ACK/NAK Transmission Fail IndicationDisableEnable *Reserved (Always 0) | ||
. Notes
ACK/NAK Retry Count ranges from 00h (never retry) to FFh (always retry).
Get RS232 (BT)
Descriptions
Request the desired one or more parameters of the RS232 Interface settings
Available for F, L & A series
Packet Format
| Prefix | Opcode | Status | Length | Parameter(s) | LRC | Suffix | |||
| 7Eh | C3h | 00h | 00h | Variable | See Below | Variable | 7Eh | ||
| 1 Byte | 3 | Bytes | 1 Byte | 2 Bytes | Variable | 1 Byte | 1 Byte | ||
| Parameter(s) | |||||||||
| First Parameter | ...... | Last Parameter | |||||||
| PID Size | PID Size | ||||||||
| 2 Bytes | 2 Bytes | ...... | 2 Bytes | 2 Bytes | |||||
| See Next Page | |||||||||
. Host Requirements
If the device successfully received the above command issued by the host, the device will pack all requested parameters into a "Reply RS232" message string then send to the host. Please refer to the "Reply RS232" command for details. Otherwise, a "Device NAK" will be sent to host to indicate issue a command error. However, if the host can receive any response from the device within the user preset time-out duration, please resend the above command.
. Parameter(s) Field
Get RS232 command can request multiple parameters at one time, so it takes compound parameters.
. Length
Total size (bytes) of the Parameter(s) field
.LRC
"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"
. Size
Total size (bytes) of the Options field
Parameter(s)
< Table 5-4-2 > Get RS232 Parameter(s) Field
| Parameter PID Size | ||
| STX/ETX Transmission 00h 00h | 00h 00h | |
| Handshaking Protocol 00h 01h | 00h 00h | |
| Baud Rate 00h 02h | 00h 00h | |
| Data Frame 00h 03h | 00h 00h | |
| Serial Response Time-out 00h 04h | 00h 00h | |
| ACK/NAK Retry Count 00h 05h | 00h 00h | |
| ACK/NAK Indication 00h 06h | 00h 00h |
Reply RS232 (BT)
Descriptions
Reply RS232 Interface Settings
Reply RS232 is sent by the device in response to the Get RS232 command. It sends the values for all the desired parameters requested in the Get RS232 command.
Available for F, L & A series
Packet Format
| Prefix | Opcode | Status | Length | Parameter(s) | LRC | Suffix | ||
| 7Eh | 04h | 00h | 00h | Variable | See Below Variable | 7Eh | ||
| 1 Byte | 3 | Bytes | 1 Byte | 2 Bytes | Variable | 1 Byte | 1 Byte | |
| Parameter(s) | ||||||
| First Parameter | ...... | Last Parameter | ||||
| PID | Size | Options | ...... | PID | Size | Options |
| 2 Bytes | 2 Bytes | Variable | ...... | 2 Bytes | 2 Bytes | Variable |
| See Next Page | ||||||
. Host Requirements
Since Reply RS232 is a device-to-host message, there is no response for this message.
. Parameter(s) Field
Set RS232 command can change multiple parameters at one time, so it takes compound parameters.
. Length
Total size (bytes) of the Parameter(s) field
.LRC
"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"
. Size
Total size (bytes) of the Options field
Parameter(s)
< Table 5-4-3 > Reply RS232 Parameter(s) Field
| Parameter / PID / Size Options Descriptions | ||||
| STX/ETX TransmissionPID : 00h 00hSize : 00h 01h (1 Byte) | - 00h- 01h | Disable *Enable | ||
| Handshaking ProtocolPID : 00h 01hSize : 00h 03h (3 Bytes) | 1^st 3^rd Byte- 00h 00h 00h- 01h 00h 00h- 00h 00h 01h- 00h 01h 00h | None *RTS/CTSACK/NAKXon/Xoff | ||
| Baud RatePID : 00h 02hSize : 00h 01h (1 Byte) | - 02h- 03h- 04h- 05h | - 06h- 07h- 08h- 09h | 1200 BPS2400 BPS4800 BPS9600 BPS * | 19200 BPS38400 BPS57600 BPS115200 BPS |
| Data Frame(Data Bit, Parity, Stop Bit )PID : 00 03Size : 00h 01h (1 Byte) | - 02h- 05h- 08h | - 09h- 0Ah- 0Bh | 8, None, 1 *8, Even, 18, Odd, 1 | 8, None, 28, Space, 18, Mark, 1 |
| Serial Response Time-outPID : 00h 04hSize : 00h 01h (1 Byte) | - 01h- 04h- 09h- 0Fh- 12h- 24h- 4Fh- 50h- 48h- 56h- 5Ah- 61h | None200 ms500 ms *800 ms1 s2 s3 s4 s5 s8 s10 s15 s | ||
| ACK/NAK Retry CountPID : 00h 05hSize : 00h 01h (1 Byte) | - 03h- XXh | 3 times * (See Note)User-defined: XXh =desired seconds(h) | ||
| ACK/NAK IndicationPID : 00h 06hSize : 00h 01h (1 Byte) | Bit 0- 0- 1Bit 1 ~ 7 | ACK/NAK Transmission Fail IndicationDisableEnable *Reserved (Always 0) | ||
.Notes
ACK/NAK Retry Count ranges from 00h (never retry) to FFh (always retry).
Command Descriptions
Set Bluetooth (BT)
Descriptions
Change the desired one or more parameters of the Bluetooth settings
Available for F, L & A series
Packet Format
| Prefix | Opcode | Status | Length | Parameter(s) | LRC | Suffix | ||
| 7Eh | 98h | 00h | 00h | Variable | See Below Variable | 7Eh | ||
| 1 Byte | 3 | Bytes | 1 Byte | 2 Bytes | Variable | 1 Byte | 1 Byte | |
| Parameter(s) | ||||||
| First Parameter | ...... | Last Parameter | ||||
| PID | Size | Options | ...... | PID | Size | Options |
| 2 Bytes | 2 Bytes | Variable | ...... | 2 Bytes | 2 Bytes | Variable |
| See Next Page | ||||||
. Host Requirements
If the device successfully received the above command issued by the host, a "Device ACK" will send to the host right after the device performed the action. Otherwise, a "Device NAK" will be sent to host to issue a command error. However, if the host can not receive any response from the device within the user preset time-out duration, please resend the above command.
. Parameter(s) Field
Set USB COM can change multiple parameters at one time, so it takes compound parameters.
. Length
Total size (bytes) of the Parameter(s) field
.LRC
"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"
. Size
Total size (bytes) of the Options field
Parameter(s)
< Table 5-5-1 > Set Bluetooth Parameter(s) Field
| Parameter / PID / Size Options Descriptions | ||||
| Bluetooth Device Name(F & L Series)PID : 00h 00hSize : 00h 11h (17 Bytes) | - 00h FFh... FFh(sixteen “FFh”s)- XXh XXh...XXh | Default * (For example: F680BT-012E)User defined(See Notes) | ||
| Bluetooth PIN CodePID : 00h 01hSize : 00h 09h (9 Bytes) | - 30h...30h 00h(eight “30h”s)- XXh XXh...XXh | Defaults to “00000000”User defined(See Notes) | ||
| BT AuthenticationPID : 00h 02hSize : 00h 01h (1 Byte) | - 00h- 01h | DisableEnable * | ||
| Sleep Timeout ControlPID : 00h 03hSize : 00h 02h (2 Bytes) | 1^st Byte- 00h- 06h- XXh 2^nd Byte- 00h- 01h- XXh | Sleep Timeout of Connect StateNever enter sleep mode6 (x5) minutes *User defined 0~99 (x5) minutesSleep Timeout of Disconnect StateNever enter sleep mode1 minute *User defined 0~99 minutes | ||
| Link Supervision TimeoutPID : 00h 04hSize : 00h 01h (1 Byte) | - 00h- 01h- 02h | - 03h- 04h | 1 s3 s *5 s | 7 s9 s |
| HID Link Quality SettingPID : 00h 05hSize : 00h 01h (1 Byte) | - 00h- 01h | DisableEnable * | ||
| Bluetooth Power Saving ModePID : 00h 06hSize : 00h 01h (1 Byte) | - 00h- 01h | Disable *Enable | ||
| Variable PIN CodePID : 00h 07hSize : 00h 01h (1 Byte) | - 00h- 01h | Disable *Enable | ||
.Notes
- User Defined Bluetooth Device Name (F & L Series) can be set to a 16-character name, the device name should be followed by a 00h. If the device name is less than 16 characters, the rest should be set to FFh. For example, if you want to set the name to "BT-1", this parameter should be "42, 54, 2D, 31, 00, FF, FF, FF, FF, FF, FF, FF, FF, FF, FF, FF"
- User Defined Bluetooth PIN Code can be set to an 8-character name, the PIN Code should be followed by a 00h. If the PIN Code is less than 8 characters, the rest should be set to FFh. For example, to set PIN code to "1234", this parameter should be "31, 32, 33, 34, 00, FF, FF, FF, FF"
Parameter(s)
< Table 5-5-1 > Set Bluetooth Parameter(s) Field
| Parameter / PID / Size Options Descriptions | ||
| Auto Power Off TimeoutPID : 00h 08hSize : 00h 01h (1 Byte) | - 06h- 00h~0Ch | (See Notes)6 (x5) minutes *User defined 0~12 (x5) minutes |
| Bluetooth Device Name(A Series)PID : 00h 09hSize : 00h 21h (33 Bytes) | - 00h FFh... FFh(thirty-two “FFh”s)- XXh XXh...XXh | Default *User defined (See Notes) |
.Notes
- Auto Power Off Timeout is available for A Series only.
- User Defined Bluetooth Device Name (A Series) can be set to a 32-character name, the device name should be followed by a 00h. If the device name is less than 32 characters, the rest should be set to FFh. For example, if you want to set the name to "BT-1", this parameter should be "42, 54, 2D, 31, 00, FF, FF, FF, FF, FF, FF, FF, FF, FF, FF, FF, FF, FF, FF, FF, FF, FF, FF, FF, FF, FF, FF, FF, FF, FF, FF, FF, FF, FF"
Command Descriptions
Get Bluetooth (BT)
Descriptions
Request the desired one or more parameters of the Bluetooth Settings
Available for F, L & A series
Packet Format
| Prefix | Opcode | Status | Length | Parameter(s) | LRC | Suffix | |||
| 7Eh | D9h | 00h | 00h | Variable | See Below | Variable | 7Eh | ||
| 1 Byte | 3 | Bytes | 1 Byte | 2 Bytes | Variable | 1 Byte | 1 Byte | ||
| Parameter(s) | |||||||||
| First Parameter | ...... | Last Parameter | |||||||
| PID Size ...... | PID Size | ||||||||
| 2 Bytes | 2 Bytes | ...... | 2 Bytes | 2 Bytes | |||||
| See Next Page | |||||||||
. Host Requirements
If the device successfully received the above command issued by the host, the device will pack all requested parameters into a "Reply Bluetooth" message string then send to the host. Please refer to the "Reply Bluetooth" command for details. Otherwise, a "Device NAK" will be sent to host to indicate issue a command error. However, if the host can receive any response from the device within the user preset time-out duration, please resend the above command.
. Parameter(s) Field
Get Bluetooth can request multiple parameters at one time, so it takes compound parameters.
. Length
Total size (bytes) of the Parameter(s) field
.LRC
"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"
. Size
Total size (bytes) of the Options field
Parameter(s)
< Table 5-5-2 > Get Bluetooth Parameter(s) Field
| Parameter PID Size | ||
| Bluetooth Device Name (F & L Series) 00h 00h | 00h | 00h 00h |
| Bluetooth PIN Code 00h 01h | 00h 00h | |
| BT Authentication 00h 02h | 00h 00h | |
| Sleep Timeout Control 00h 03h | 00h 00h | |
| Link Supervision Timeout 00h 04h | 00h 00h | |
| HID Link Quality Settings 00h 05h | 00h 00h | |
| Bluetooth Power Saving Mode 00h 06h | 00h 00h | |
| Variable PIN Code 00h 07h | 00h 00h | |
| Auto Power Off Timeout 00h 08h | 00h 00h | |
| Bluetooth Device Name (A Series) | 00h 09h | 00h 00h |
Reply Bluetooth (BT)
Descriptions
Reply the desired one or more parameters of the Bluetooth Settings
Reply Bluetooth is sent by the device in response to the Get Bluetooth command. It sends the values for all the desired parameters requested in the Get Bluetooth command.
Available for F, L & A series
Packet Format
| Prefix | Opcode | Status | Length | Parameter(s) | LRC | Suffix | ||
| 7Eh | 1Ah | 00h | 00h | Variable | See Below Variable | 7Eh | ||
| 1 Byte | 3 | Bytes | 1 Byte | 2 Bytes | Variable | 1 Byte | 1 Byte | |
| Parameter(s) | ||||||
| First Parameter | ...... | Last Parameter | ||||
| PID | Size | Options | ...... | PID | Size | Options |
| 2 Bytes | 2 Bytes | Variable | ...... | 2 Bytes | 2 Bytes | Variable |
| See Next Page | ||||||
. Host Requirements
If the device successfully received the above command issued by the host, a "Device ACK" will send to the host right after the device performed the action. Otherwise, a "Device NAK" will be sent to host to issue a command error. However, if the host can not receive any response from the device within the user preset time-out duration, please resend the above command.
. Parameter(s) Field
Set USB COM can change multiple parameters at one time, so it takes compound parameters.
. Length
Total size (bytes) of the Parameter(s) field
.LRC
"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"
. Size
Total size (bytes) of the Options field
Parameter(s)
< Table 5-5-3 > Reply Bluetooth Parameter(s) Field
| Parameter / PID / Size Options Descriptions | ||||
| Bluetooth Device Name(F & L Series)PID : 00h 00hSize : 00h 11h (17 Bytes) | - 00h FFh... FFh(sixteen “FFh”s)- XXh XXh...XXh | Default * (For example: F680BT-012E)User defined(See Notes) | ||
| Bluetooth PIN CodePID : 00h 01hSize : 00h 09h (9 Bytes) | - 30h...30h 00h(eight “30h”s)- XXh XXh...XXh | Defaults to “00000000”User defined(See Notes) | ||
| BT AuthenticationPID : 00h 02hSize : 00h 01h (1 Byte) | - 00h- 01h | DisableEnable * | ||
| Sleep Timeout ControlPID : 00h 03hSize : 00h 02h (2 Bytes) | 1^st Byte- 00h- 06h- XXh 2^nd Byte- 00h- 01h- XXh | Sleep Timeout of Connect StateNever enter sleep mode6 (x5) minutes *User defined 0~99 (x5) minutesSleep Timeout of Disconnect StateNever enter sleep mode1 minute *User defined 0~99 minutes | ||
| Link Supervision TimeoutPID : 00h 04hSize : 00h 01h (1 Byte) | - 00h- 01h- 02h | - 03h- 04h | 1 s3 s *5 s | 7 s9 s |
| HID Link Quality SettingPID : 00h 05hSize : 00h 01h (1 Byte) | - 00h- 01h | DisableEnable * | ||
| Bluetooth Power Saving ModePID : 00h 06hSize : 00h 01h (1 Byte) | - 00h- 01h | Disable *Enable | ||
| Variable PIN CodePID : 00h 07hSize : 00h 01h (1 Byte) | - 00h- 01h | Disable *Enable | ||
.Notes
- User Defined Bluetooth Device Name is a maximum 16-character name, which is followed by a 00h. If the device name is less than 16 characters, the rest should be set to FFh. For example, if the name is "BT-1", this parameter should be "42, 54, 2D, 31, 00, FF, FF, FF, FF, FF, FF, FF, FF, FF, FF, FF, FF"
- User Defined Bluetooth PIN Code is a maximum 8-character name, the PIN Code is followed by a 00h. If the PIN Code is less than 8 characters, the rest is filled with FFh. For example, if the PIN code is "1234", this parameter should be "31, 32, 33, 34, 00, FF, FF, FF, FF"
Parameter(s)
< Table 5-5-3 > Reply Bluetooth Parameter(s) Field
| Parameter / PID / Size Options Descriptions | ||
| Auto Power Off TimeoutPID : 00h 08hSize : 00h 01h (1 Byte) | - 06h- 00h~0Ch | (See Notes)6 (x5) minutes *User defined 0~12 (x5) minutes |
| Bluetooth Device Name(A Series)PID : 00h 09hSize : 00h 21h (33 Bytes) | - 00h FFh... FFh(thirty-two “FFh”s)- XXh XXh...XXh | Default *User defined(See Notes) |
Notes
- Auto Power Off Timeout is available for A Series only.
- User Defined Bluetooth Device Name (A Series) can be set to a 32-character name, the device name should be followed by a 00h. If the device name is less than 32 characters, the rest should be set to FFh. For example, if you want to set the name to "BT-1", this parameter should be "42, 54, 2D, 31, 00, FF, FF, FF, FF, FF, FF, FF, FF, FF, FF, FF, FF, FF, FF, FF, FF, FF, FF, FF, FF, FF, FF, FF, FF, FF, FF, FF, FF, FF, FF"
Command Descriptions
Set USB HID (WF)
Descriptions
Change the desired one or more parameters of the USB HID Interface settings
Available for F & L series
Packet Format
| Prefix | Opcode | Status | Length | Parameter(s) | LRC | Suffix | ||
| 7Eh | 82h | 00h | 02h | 00h | Variable | See Below | Variable | 7Eh |
| 1 Byte | 3 | Bytes | 1 Byte | 2 Bytes | / | Variable | 1 Byte |
| Parameter(s) | ||||||
| First Parameter | ...... | Last Parameter | ||||
| PID | Size | Options | ...... | PID | Size | Options |
| 2 Bytes | 2 Bytes | Variable | ...... | 2 Bytes | 2 Bytes | Variable |
| See Next Page | ||||||
. Host Requirements
If the device successfully received the above command issued by the host, a "Device ACK" will send to the host right after the device performed the action. Otherwise, a "Device NAK" will be sent to host to issue a command error. However, if the host can not receive any response from the device within the user preset time-out duration, please resend the above command.
. Parameter(s) Field
Set USB HID command can change multiple parameters at one time, so it takes compound parameters.
. Length
Total size (bytes) of the Parameter(s) field
.LRC
"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"
. Size
Total size (bytes) of the Options field
Parameter(s)
< Table 5-6-1 > Set USB HID Parameter(s) Field
| Parameter / PID / Size Options Descriptions | ||
| Keyboard LayoutPID : 00h 01hSize : 00h 01h (1 Byte) | - 00h- 03h- 04h- 07h- 0Bh- 0Ah- 02h- 0Ch- 09h- 0Dh- 05h- 0Eh- 08h- 01h- 06h- 0Fh- 10h- 11h- 62h | USA (QWERTY) *France (AZERTY)Germany (QWERTZ)United Kingdom – UK (QWERTY)Canadian French (QWERTY)Spain (Spanish, QWERTY)Sweden/Finland (QWERTY)Portugal (QWERTY)Norway (QWERTY)Spain (Latin America, QWERTY)Italy (QWERTY)Netherlands (QWERTY)Denmark (QWERTY)BelgiumSwitzerland – Germany (QWERTY)Iceland (QWERTY)Japan (DOS/V)Czech (QWERTY)Universal |
| Caps Lock ReleasePID : 00h 02hSize : 00h 01h (1 Byte) | - 00h- 01h | “Caps Lock On, Caps Off”“Caps Lock On, Shift Off” |
| Caps LockPID : 00h 03hSize : 00h 01h (1 Byte) | - 00h- 01h- 06h | “Caps Lock Off” State “Caps Lock On” StateAuto Detect |
| Function Key EmulationPID : 00h 04hSize : 00h 01h (1 Byte) | - 00h- 01h | Enable ASCII 00-31 code as keyboard function code *Ctrl-Output |
| Key Pad EmulationPID : 00h 05hSize : 00h 01h (1 Byte) | - 00h- 01h | Disable *Enable |
| Upper/Lower CasePID : 00h 06hSize : 00h 01h (1 Byte) | - 00h- 01h- 02h- 03h | Normal case *Inverse caseUpper caseLower case |
Get USB HID (WF)
Descriptions
Request the desired one or more parameters of the USB HID Interface settings Available for F & L series
Packet Format
| Prefix | Opcode | Status | Length | Parameter(s) | LRC | Suffix | |||
| 7Eh | C3h 00h 02h | 00h | Variable | See Below Variable | 7Eh | ||||
| 1 Byte | 3 | Bytes | 1 Byte | 2 Bytes | Variable | 1 Byte | 1 Byte | ||
| Parameter(s) | |||||||||
| First Parameter | ...... | Last Parameter | |||||||
| PID Size ...... | PID Size | ||||||||
| 2 Bytes | 2 Bytes | ...... | 2 Bytes | 2 Bytes | |||||
| See Next Page | |||||||||
. Host Requirements
If the device successfully received the above command issued by the host, the device will pack all requested parameters into a "Reply USB HID" message string then send to the host. Please refer to the "Reply USB HID" command for details. Otherwise, a "Device NAK" will be sent to host to indicate issue a command error. However, if the host can receive any response from the device within the user preset time-out duration, please resend the above command.
. Parameter(s) Field
Get USB HID command can request multiple parameters at one time, so it takes compound parameters.
. Length
Total size (bytes) of the Parameter(s) field
.LRC
"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"
. Size
Total size (bytes) of the Options field
Parameter(s)
< Table 5-6-2 > Get USB HID Parameter(s) Field
| Parameter PID Size | ||
| Keyboard Layout 00h 01h | 00h 00h | |
| Caps Lock Release 00h 02h | 00h 00h | |
| Caps Lock 00h 03h | 00h 00h | |
| Function Key Emulation 00h 04h | 00h 00h | |
| Key Pad Emulation 00h 05h | 00h 00h | |
| Upper/Lower Case 00h 06h | 00h 00h |
Reply USB HID (WF)
Descriptions
Reply USB HID Interface Settings
Reply USB HID is sent by the device in response to the Get USB HID command. It sends the values for all the desired parameters requested in the Get USB HID command.
Available for F & L series
Packet Format
| Prefix | Opcode | Status | Length | Parameter(s) | LRC | Suffix | |||
| 7Eh | 04h | 00h | 02h | 00h | Variable | See Below | Variable | 7Eh | |
| 1 Byte | 3 | Bytes | 1 Byte | 2 Bytes | Variable | 1 Byte | 1 Byte | ||
| Parameter(s) | |||||||||
| First Parameter ...... | Last Parameter | ||||||||
| PID | Size | Options | ...... | PID | Size | Options | |||
| 2 Bytes | 2 Bytes | Variable | ...... | 2 Bytes | 2 Bytes | Variable | |||
| See Next Page | |||||||||
. Host Requirements
Since Reply USB HID is a device-to-host message, there is no response for this message.
. Parameter(s) Field
Set USB HID command can change multiple parameters at one time, so it takes compound parameters.
. Length
Total size (bytes) of the Parameter(s) field
.LRC
"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"
. Size
Total size (bytes) of the Options field
Parameter(s)
< Table 5-6-3 > Reply USB HID Parameter(s) Field
| Parameter / PID / Size Options Descriptions | ||
| Keyboard LayoutPID : 00h 01hSize : 00h 01h (1 Byte) | - 00h- 03h- 04h- 07h- 0Bh- 0Ah- 02h- 0Ch- 09h- 0Dh- 05h- 0Eh- 08h- 01h- 06h- 0Fh- 10h- 11h- 62h | USA (QWERTY) *France (AZERTY)Germany (QWERTZ)United Kingdom – UK (QWERTY)Canadian French (QWERTY)Spain (Spanish, QWERTY)Sweden/Finland (QWERTY)Portugal (QWERTY)Norway (QWERTY)Spain (Latin America, QWERTY)Italy (QWERTY)Netherlands (QWERTY)Denmark (QWERTY)BelgiumSwitzerland – Germany (QWERTY)Iceland (QWERTY)Japan (DOS/V)Czech (QWERTY)Universal |
| Caps Lock ReleasePID : 00h 02hSize : 00h 01h (1 Byte) | - 00h- 01h | “Caps Lock On, Caps Off”“Caps Lock On, Shift Off” |
| Caps LockPID : 00h 03hSize : 00h 01h (1 Byte) | - 00h- 01h- 06h | “Caps Lock Off” State “Caps Lock On” StateAuto Detect |
| Function Key EmulationPID : 00h 04hSize : 00h 01h (1 Byte) | - 00h- 01h | Enable ASCII 00-31 code as keyboard function code *Ctrl-Output |
| Key Pad EmulationPID : 00h 05hSize : 00h 01h (1 Byte) | - 00h- 01h | Disable *Enable |
| Upper/Lower CasePID : 00h 06hSize : 00h 01h (1 Byte) | - 00h- 01h- 02h- 03h | Normal case *Inverse caseUpper caseLower case |
Set USB COM (WF)
Descriptions
Change the desired one or more parameters of the USB COM Interface settings Available for F & L series
Packet Format
| Prefix | Opcode | Status | Length | Parameter(s) | LRC | Suffix | |||
| 7Eh | 82h | 00h | 03h | 00h | Variable | See Below | Variable | 7Eh | |
| 1 Byte | 3 | Bytes | 1 Byte | 2 Bytes | Variable | 1 Byte | 1 Byte | ||
| Parameter(s) | |||||||||
| First Parameter | ...... | Last Parameter | |||||||
| PID | Size | Options | ...... | PID | Size | Options | |||
| 2 Bytes | 2 Bytes | Variable | ...... | 2 Bytes | 2 Bytes | Variable | |||
| See Next Page | |||||||||
. Host Requirements
If the device successfully received the above command issued by the host, a "Device ACK" will send to the host right after the device performed the action. Otherwise, a "Device NAK" will be sent to host to issue a command error. However, if the host can not receive any response from the device within the user preset time-out duration, please resend the above command.
. Parameter(s) Field
Set USB COM can change multiple parameters at one time, so it takes compound parameters.
. Length
Total size (bytes) of the Parameter(s) field
.LRC
"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"
. Size
Total size (bytes) of the Options field
Parameter(s)
< Table 5-7-1 > Set USB COM Parameter(s) Field
| Parameter / PID / Size Options Descriptions | ||||
| STX/ETX TransmissionPID : 00h 00hSize : 00h 01h (1 Byte) | - 00h- 01h | Disable *Enable | ||
| Baud RatePID : 00h 02hSize : 00h 01h (1 Byte) | - 02h- 03h- 04h- 05h | - 06h- 07h- 08h- 09h | 1200 BPS2400 BPS4800 BPS9600 BPS * | 19200 BPS38400 BPS57600 BPS115200 BPS |
| Data Frame(Data Bit, Parity, Stop Bit )PID : 00 03Size : 00h 01h (1 Byte) | - 02h- 08h- 05h- 0Ah- 0Bh- 09h- 06h- 03h | - 0Ch- 0Dh- 01h- 07h- 04h- 0Eh- 0Fh | 8, None, 1 *8, Odd, 18, Even, 18, Space, 18, Mark, 18, None, 27, Odd, 17, Even, 1 | 7, Space, 17, Mark, 17, None, 27, Odd, 27, Even, 27, Space, 27, Mark, 2 |
Get USB COM (WF)
Descriptions
Request the desired one or more parameters of the USB COM Interface settings Available for F & L series
Packet Format
| Prefix | Opcode | Status | Length | Parameter(s) | LRC | Suffix | |||
| 7Eh | C3h | 00h | 03h | 00h | Variable | See Below Variable | 7Eh | ||
| 1 Byte | 3 | Bytes | 1 Byte | 2 Bytes | Variable | 1 Byte | 1 Byte | ||
| Parameter(s) | |||||||||
| First Parameter | ...... | Last Parameter | |||||||
| PID Size ...... | PID Size | ||||||||
| 2 Bytes | 2 Bytes | ...... | 2 Bytes | 2 Bytes | |||||
| See Next Page | |||||||||
. Host Requirements
If the device successfully received the above command issued by the host, the device will pack all requested parameters into a "Reply USB COM" message string then send to the host. Please refer to the "Reply USB COM" command for details. Otherwise, a "Device NAK" will be sent to host to indicate issue a command error. However, if the host can receive any response from the device within the user preset time-out duration, please resend the above command.
. Parameter(s) Field
Get USB COM can request multiple parameters at one time, so it takes compound parameters.
. Length
Total size (bytes) of the Parameter(s) field
.LRC
"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"
. Size
Total size (bytes) of the Options field
Parameter(s)
< Table 5-7-2 > Get USB COM Parameter(s) Field
| Parameter PID Size | ||
| STX/ETX Transmission 00h 00h | 00h 00h | |
| Baud Rate 00h 02h | 00h 00h | |
| Data Frame 00h 03h | 00h 00h |
Reply USB COM (WF)
Descriptions
Reply the desired one or more parameters of the USB COM Interface settings
Reply USB COM is sent by the device in response to the Get USB COM command. It sends the values for all the desired parameters requested in the Get USB COM command.
Available for F & L series
Packet Format
| Prefix | Opcode | Status | Length | Parameter(s) | LRC | Suffix | |||
| 7Eh | 04h | 00h | 03h | 00h | Variable | See Below Variable | 7Eh | ||
| 1 Byte | 3 | Bytes | 1 Byte | 2 Bytes | Variable | 1 Byte | 1 Byte | ||
| Parameter(s) | |||||||||
| First Parameter | ...... | Last Parameter | |||||||
| PID | Size | Options | ...... | PID | Size | Options | |||
| 2 Bytes | 2 Bytes | Variable | ...... | 2 Bytes | 2 Bytes | Variable | |||
| See Next Page | |||||||||
. Host Requirements
Since Reply USB COM is a device-to-host message, there is no response for this message.
. Parameter(s) Field
Set USB COM can change multiple parameters at one time, so it takes compound parameters.
. Length
Total size (bytes) of the Parameter(s) field
.LRC
"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"
. Size
Total size (bytes) of the Options field
Parameter(s)
< Table 5-7-3 > Reply USB COM Parameter(s) Field
| Parameter / PID / Size Options Descriptions | ||||
| STX/ETX TransmissionPID : 00h 00hSize : 00h 01h (1 Byte) | - 00h- 01h | Disable *Enable | ||
| Baud RatePID : 00h 02hSize : 00h 01h (1 Byte) | - 02h- 03h- 04h- 05h | - 06h- 07h- 08h- 09h | 1200 BPS2400 BPS4800 BPS9600 BPS * | 19200 BPS38400 BPS57600 BPS115200 BPS |
| Data Frame(Data Bit, Parity, Stop Bit )PID : 00 03Size : 00h 01h (1 Byte) | - 02h- 08h- 05h- 0Ah- 0Bh- 09h- 06h- 03h | - 0Ch- 0Dh- 01h- 07h- 04h- 0Eh- 0Fh | 8, None, 1 *8, Odd, 18, Even, 18, Space, 18, Mark, 18, None, 27, Odd, 17, Even, 1 | 7, Space, 17, Mark, 17, None, 27, Odd, 27, Even, 27, Space, 27, Mark, 2 |
Command Descriptions
Set Wi-Fi (WF)
Descriptions
Change the desired one or more parameters of the Wi-Fi settings
Available for F & L series
Packet Format
| Prefix | Opcode | Status | Length | Parameter(s) | LRC | Suffix | ||
| 7Eh | 9Bh | 00h | 00h | Variable | See Below Variable | 7Eh | ||
| 1 Byte | 3 | Bytes | 1 Byte | 2 Bytes | / | Variable | 1 Byte | |
| Parameter(s) | ||||||
| First Parameter ...... | Last Parameter | |||||
| PID | Size | Options | ...... | PID | Size | Options |
| 2 Bytes | 2 Bytes | Variable | ...... | 2 Bytes | 2 Bytes | Variable |
| See Next Page | ||||||
. Host Requirements
If the device successfully received the above command issued by the host, a "Device ACK" will send to the host right after the device performed the action. Otherwise, a "Device NAK" will be sent to host to issue a command error. However, if the host can not receive any response from the device within the user preset time-out duration, please resend the above command.
. Parameter(s) Field
Set USB COM can change multiple parameters at one time, so it takes compound parameters.
. Length
Total size (bytes) of the Parameter(s) field
.LRC
"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"
. Size
Total size (bytes) of the Options field
Parameter(s)
< Table 5-8-1 > Set Wi-Fi Parameter(s) Field
| Parameter / PID / Size Options Descriptions | ||
| Sleep Timeout ControlPID : 00h 14hSize : 00h 02h (2 Bytes) | 1^st Byte- 00h- 06h- XXh 2^nd Byte- 00h- 05h- XXh | Sleep Timeout of Connect StateNever enter sleep mode6 (x5) minutes *User defined 0~99 (x5) minutesSleep Timeout of Disconnect StateNever enter sleep mode5 minute *User defined 0~99 minutes |
| Keep Alive TimeoutPID : 00h 15hSize : 00h 02h (2 Bytes) | 1^st Byte- 00h- 01h- 03h- 06h 2^nd Byte- 00h | Keep Alive TimeoutDisable10 seconds *30 seconds60 secondsReserved (Always Zero) |
| Reconnect IntervalPID : 00h 16hSize : 00h 01h (1 Byte) | - 02h- XXh | 2 seconds *User defined 0~255 seconds |
| Power Saving ModePID : 00h 17hSize : 00h 01h (1 Byte) | - 00h- 01h | Disable *Enable |
| COM Port ValidationPID : 01h 00hSize : 00h 01h (1 Byte) | - 00h- 01h | Disable *Enable |
Get Wi-Fi (WF)
Descriptions
Request the desired one or more parameters of the Wi-Fi settings Available for F & L series
Packet Format
| Prefix | Opcode | Status | Length | Parameter(s) | LRC | Suffix | |||
| 7Eh | DCh 00h 00h | 00h | Variable | See Below Variable | 7Eh | ||||
| 1 Byte | 3 | Bytes | 1 Byte | 2 Bytes | Variable | 1 Byte | 1 Byte | ||
| Parameter(s) | |||||||||
| First Parameter | ...... | Last Parameter | |||||||
| PID Size ...... | PID Size | ||||||||
| 2 Bytes | 2 Bytes | ...... | 2 Bytes | 2 Bytes | |||||
| See Next Page | |||||||||
. Host Requirements
If the device successfully received the above command issued by the host, the device will pack all requested parameters into a "Reply Wi-Fi" message string then send to the host. Please refer to the "Reply Wi-Fi" command for details. Otherwise, a "Device NAK" will be sent to host to indicate issue a command error. However, if the host can receive any response from the device within the user preset time-out duration, please resend the above command.
. Parameter(s) Field
Get USB COM can request multiple parameters at one time, so it takes compound parameters.
. Length
Total size (bytes) of the Parameter(s) field
.LRC
"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"
. Size
Total size (bytes) of the Options field
Parameter(s)
< Table 5-8-2 > Get Wi-Fi Parameter(s) Field
| Parameter PID Size | ||
| Wi-Fi MAC Address 00h 0Ch | 00h 00h | |
| Sleep Timeout Control 00h 14h | 00h 00h | |
| Keep Alive Timeout 00h 15h | 00h 00h | |
| Reconnect Interval 00h 16h | 00h 00h | |
| Power Saving Mode 00h 17h | 00h 00h | |
| COM Port Validation 01h 00h | 00h 00h |
Reply Wi-Fi (WF)
Descriptions
Reply the desired one or more parameters of the Wi-Fi Interface settings
Reply Wi-Fi is sent by the device in response to the Get Wi-Fi command. It sends the values for all the desired parameters requested in the Get Wi-Fi command.
Available for F & L series
Packet Format
| Prefix | Opcode | Status | Length | Parameter(s) | LRC | Suffix | |||
| 7Eh | 1Dh | 00h | 00h | Variable | See Below | Variable | 7Eh | ||
| 1 Byte | 3 | Bytes | 1 Byte | 2 Bytes | Variable | 1 Byte | 1 Byte | ||
| Parameter(s) | |||||||||
| First Parameter ...... | Last Parameter | ||||||||
| PID | Size | Options | ...... | PID | Size | Options | |||
| 2 Bytes | 2 Bytes | Variable | ...... | 2 Bytes | 2 Bytes | Variable | |||
| See Next Page | |||||||||
. Host Requirements
Since Reply USB COM is a device-to-host message, there is no response for this message.
. Parameter(s) Field
Set USB COM can change multiple parameters at one time, so it takes compound parameters.
. Length
Total size (bytes) of the Parameter(s) field
.LRC
"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"
. Size
Total size (bytes) of the Options field
Parameter(s)
< Table 5-8-3 > Reply Wi-Fi Parameter(s) Field
| Parameter / PID / Size Options Descriptions | ||
| Wi-Fi MAC AddressPID : 00h 0ChSize : 00h 06h (6 Bytes) | 1^st Byte- XXh 2^nd Byte- XXh 3^rd Byte- XXh 4^th Byte- XXh 5^th Byte- XXh 6^th Byte- XXh | The 6th number of MAC AddressUser defined XXThe 5th number of MAC AddressUser defined XXThe 4th number of MAC AddressUser defined XXThe 3rd number of MAC AddressUser defined XXThe 2nd number of MAC AddressUser defined XXThe 1st number of MAC AddressUser defined XX |
| Sleep Timeout ControlPID : 00h 14hSize : 00h 02h (2 Bytes) | 1^st Byte- 00h- 06h- XXh 2^nd Byte- 00h- 05h- XXh | Sleep Timeout of Connect StateNever enter sleep mode6 (x5) minutes *User defined 0~99 (x5) minutesSleep Timeout of Disconnect StateNever enter sleep mode5 minute *User defined 0~99 minutes |
| Keep Alive TimeoutPID : 00h 15hSize : 00h 02h (2 Bytes) | 1^st Byte- 00h- 01h- 03h- 06h 2^nd Byte- 00h | Keep Alive TimeoutDisable10 seconds *30 seconds60 secondsReserved (Always Zero) |
| Reconnect IntervalPID : 00h 16hSize : 00h 01h (1 Byte) | - 02h- XXh | 2 seconds *User defined 0~255 seconds |
| Power Saving ModePID : 00h 17hSize : 00h 01h (1 Byte) | - 00h- 01h | Disable *Enable |
| COM Port ValidationPID : 01h 00hSize : 00h 01h (1 Byte) | - 00h- 01h | Disable *Enable |
2.6 Operation
Set TS Operation (TS)
Descriptions
Change the desired one or more parameters of the Operation Settings for Tethered Scanner Available for F, L & A series
Packet Format
| Prefix | Opcode | Status | Length | Parameter(s) | LRC | Suffix | |||
| 7Eh | 88h | 00h | 00h | Variable | See Below | Variable | 7Eh | ||
| 1 Byte | 3 | Bytes | 1 Byte | 2 Bytes | Variable | 1 Byte | 1 Byte | ||
| Parameter(s) | |||||||||
| First Parameter | ...... | Last Parameter | |||||||
| PID | Size | Options | ...... | PID | Size | Options | |||
| 2 Bytes | 2 Bytes | Variable | ...... | 2 Bytes | 2 Bytes | Variable | |||
| See Next Page | |||||||||
. Host Requirements
If the device successfully received the above command issued by the host, a "Device ACK" will send to the host right after the device performed the action. Otherwise, a "Device NAK" will be sent to host to issue a command error. However, if the host can not receive any response from the device within the user preset time-out duration, please resend the above command.
. Parameter(s) Field
Set TS Operation can change multiple parameters at one time, so it takes compound parameters.
. Length
Total size (bytes) of the Parameter(s) field
.LRC
"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"
. Size
Total size (bytes) of the Options field
Parameter(s)
< Table 6-1-1 > Set TS Operation Parameter(s) Field (To be continued)
| Parameter / PID / Size Options Descriptions | ||||
| Presentation ControlPID : 00h 01hSize : 00h 01h (1 Byte) | - 01h- 02h- 08h | Force modePresentation mode *Flash mode (See Notes) | ||
| Presentation Auto-sensePID : 00h 02hSize : 00h 01h (1 Byte) | - 00h- 01h | Disable *Enable | ||
| Presentation SensitivityPID : 00h 03hSize : 00h 01h (1 Byte) | - 00h- 01h- 02h- 03h | - 04h- 05h- 06h | Level 1Level 2Level 3Level 4 | Level 5 *Level 6Level 7 |
| Reread DelayPID : 00h 04hSize : 00h 01h (1 Byte) | - 00h- 01h- 02h- 03h- 04h- 05h | DisableImmediate time-out duration *Short time-out durationMedium time-out durationLong time out-durationForce Verification | ||
| Flash Duty CyclePID : 00h 05hSize : 00h 01h (1 Byte) | - 00h- 01h- 02h- 03h | 1/2 duty cycle * (See Notes)2/3 duty cycle3/4 duty cycle4/5 duty cycle | ||
| Good Read DelayPID : 00h 06hSize : 00h 01h (1 Byte) | - 00h- 01h- 02h- 03h | - 04h- 05h- 06h | None*200 ms500 ms1 s | 1.5 s2 s3 s |
| Light Source On TimePID : 00h 07hSize : 00h 01h (1 Byte) | - 00h- 01h- 02h- 03h | Short (about 2 s) *Medium (about 3~4 s)Long (about 5~6 s)Extremely Long (about 7~8 s) | ||
| Hands Free Time-outPID : 00h 08hSize : 00h 01h (1 Byte) | - 00h- 06h- 0Ah | - 0Eh- 12h | DisableShort *Medium | LongExtremely long |
| Time Delay To Low Power ModePID : 00h 09hSize : 00h 01h (1 Byte) | - 00h- 01h- 02h | - 03h- 04h- 05h | 1 s3 s5 s | 7 s9 s0 s (Immediately)* |
. Notes
Flash mode is not available for A Series.
Parameter(s)
< Table 6-1-1 > Set TS Operation Parameter(s) Field (Continued)
| Parameter / PID / Size Options Descriptions | ||||
| Trigger Control(F460/468 only)PID: 00h 0AhSize: 00h 01h (2 Bytes) | - 00h- 01h- 02h | Enable left trigger, disable right triggerEnable right trigger, disable left triggerEnable left and right trigger * | ||
| Scan Rate ControlPID: 00h 0BhSize: 00h 01h (1 Byte) | - 00h- 01h | Dynamic *Fixed | ||
| Buzzer Tone AdjustPID: 01h 00hSize: 00h 02h (2 Bytes) | 1^st 2^nd Byte- 00h 00h- 01h 01h- 01h 02h- 01h 03h- 01h 04h | MuteLowMedium *HighExtremely High | ||
| Power on beepPID: 01h 01hSize: 00h 01h (1 Byte) | - 00h- 01h | EnableDisable | ||
| Power on IndicationPID: 01h 02hSize: 00h 01h (1 Byte) | - 00h- 01h- 02h | LED offLED steady on *LED flash | ||
| VibratorPID: 01h 03hSize: 00h 01h (1 Byte) | - 00h- 01h | DisableEnable * | ||
| Good Read DurationPID: 01h 04hSize: 00h 01h (1 Byte) | - 00h- 01h- 02h | - 03h- 04h | ShortMedium *Long | Extremely longExtremely short |
| Good Read IndicatorPID: 01h 05hSize: 00h 01h (1 Byte) | - 00h- 01h | (See Notes)DisableEnable * | ||
| 1D Barcode Inverse ReadingPID: 02h 00hSize: 00h 01h (1 Byte) | - 00h- 01h | Disable *Enable | ||
| Dollar Sign ControlPID: 02h 01hSize: 00h 01h (1 Byte) | - 00h- 80h- A2h | - A3h- A5h | Output as “$” *Output as “€” Output as “¢” | Output as “£” Output as “¥” |
| RedundancyPID: 02h 02hSize: 00h 01h (1 Byte) | - 00h- 01h- 02h | - 03h- 04h- 05h | None1 time *2 times | 3 times4 times5 times |
Notes
Good Read Indicator: If enabled, the Green LED flashes once after a good decode.
Parameter(s)
< Table 6-1-1 > Set TS Operation Parameter(s) Field (Continued)
| Parameter / PID / Size Options Descriptions | ||||
| Data Transmission PacketPID: 02h 04hSize: 00h 01h (1 Byte) | - 00h- 01h | Disable *Enable | ||
| UPC/EAN Security LevelPID: 02h 06hSize: 00h 01h (1 Byte) | - 00h- 01h- 02h | Level 0Level 1 *Level 2 | ||
| Supplement Scan VotingPID: 02h 08hSize: 00h 01h (1 Byte) | - 00h- 06h- 08h- 0Ah- 0Ch- 0Eh- 10h | - 12h- 14h- 16h- 18h- 1Ah- 1Ch- 1Eh | NoneLevel 1Level 2Level 3 *Level 4Level 5Level 6 | Level 7Level 8Level 9Level 10Level 11Level 12Level 13 |
| Laser Aiming ControlPID: 02h 09hSize: 00h 01h (1 Byte) | - 00h- 01h | (See Notes)DisableEnable * | ||
| LED IlluminationPID: 02h 0BhSize: 00h 01h (1 Byte) | - 00h- 01h | (See Notes)Always onIntelligent Scanning * | ||
| Illumination Delay DurationPID: 02h 0ChSize: 00h 01h (1 Byte) | - 00h- 01h- 02h- 03h- 04h | (See Notes)100ms200ms300ms400ms500ms | ||
| Operation Mode(Tethered Scanner)PID: 10h 00hSize: 00h 01h (1 Byte) | - 00h- 01h- 02h- 04h- 05h- 06h- 07h- 08h- 09h | (See Notes)Trigger mode (External triggering) *Force mode (Continued power on)Presentation mode (Auto detection)Level mode (Auto power off)Diagnostic mode (Test reading)Alternative mode (Periodic power off)Toggle mode (Repeat reading)Flash mode (Pulse driven reading)Low Power mode (Low Power triggering) | ||
.Notes
- LED Illumination, Illumination Delay Duration are only available for L680, L688, L780, L788
- Laser Aiming Control is only available for L688, L788
Parameter(s)
< Table 6-1-1 > Set TS Operation Parameter(s) Field (Continued)
| Parameter / PID / Size Options Descriptions | ||
| Operation Mode(Tethered A Series)PID : 70h 00hSize : 00h 03h (3 Bytes) | - 00h 01h 01h- 01h 01h 01h- 02h 01h 01h- 04h 01h 00h- 05h 01h 01h- 06h 01h 00h- 07h 01h 00h- 09h 01h 01h- 0Dh 01h 01h | Trigger mode *Force modePresentation modeLevel modeDiagnostic modeAlternative modeToggle modeLow Power modeMultiple mode |
| Hand-Held Mode Illumination & Aiming ControlPID : 70h 01hSize : 00h 01h (1 Byte) | Bit 0- 0- 1Bit 1- 0- 1 | Hand-Held Decode Aiming ControlDisableEnable *Hand-Held Illumination ControlDisableEnable * |
| Hand-Free Mode DecodeAiming ControlPID : 70h 02hSize : 00h 01h (1 Byte) | - 02h- 03h | DisableEnable * |
| Aiming ControlPID : 70h 03hSize : 00h 02h (2 Bytes) | - 00h 00h- 01h 00h- 00h 03h | Regular AimingIntelligent Aiming *Delay Aiming Control |
| Delay Aiming TimeoutControlPID : 70h 04hSize : 00h 01h (1 Byte) | - 02h- 04h- 08h- 0Ah- 0Fh- 14h- 1Eh- 28h | 200ms400ms *800ms1000ms1500ms2000ms3000ms4000ms |
| Presentation BackgroundLightingPID : 70h 05hSize : 00h 02h (2 Bytes) | - 00h 00h- 00h FFh | LEDs OffLEDs On * |
| Center AlignmentPID : 70h 06hSize : 00h 02h (2 Bytes) | 1st Byte- 00h- 01h2nd Byte- 00h- 01h | Hand-Held ModeDisable *EnableHand-Free ModeDisable *Enable |
Parameter(s)
< Table 6-1-1 > Set TS Operation Parameter(s) Field (Continued)
| Parameter / PID / Size Options Descriptions | ||
| Mobile Phone CapturePID : 70h 07hSize : 00h 01h (1 Byte) | - 00h- 01h | Disable *Enable |
| Unique Barcode ReportingPID : 70h 08hSize : 00h 01h (1 Byte) | - 00h- 01h | Disable *Enable |
Get TS Operation (TS)
Descriptions
Request the desired one or more parameters of the Operation Settings for Tethered Scanner Available for F, L & A series
Packet Format
| Prefix | Opcode | Status | Length | Parameter(s) | LRC | Suffix | |||
| 7Eh | C9h 00h 00h | 00h | Variable | See Below Variable | 7Eh | ||||
| 1 Byte | 3 | Bytes | 1 Byte | 2 Bytes | Variable | 1 Byte | 1 Byte | ||
| Parameter(s) | |||||||||
| First Parameter | ...... | Last Parameter | |||||||
| PID Size ...... | PID Size | ||||||||
| 2 Bytes | 2 Bytes | ...... | 2 Bytes | 2 Bytes | |||||
| See Next Page | |||||||||
. Host Requirements
If the device successfully received the above command issued by the host, the device will pack all requested parameters into a "Reply TS Operation" message string then send to the host. Please refer to the "Reply TS Operation" command for details. Otherwise, a "Device NAK" will be sent to host to indicate issue a command error. However, if the host can receive any response from the device within the user preset time-out duration, please resend the above command.
. Parameter(s) Field
Get TS Operation can request multiple parameters at one time, so it takes compound parameters.
. Length
Total size (bytes) of the Parameter(s) field
.LRC
"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"
. Size
Total size (bytes) of the Options field
Parameter(s)
< Table 6-1-2 > Get TS Operation Parameter(s) Field
| Parameter PID Size | ||
| Presentation Control 00h 01h | 00h 00h | |
| Presentation Auto-sense 00h 02h | 00h 00h | |
| Presentation Sensitivity 00h 03h | 00h 00h | |
| Reread Delay 00h 04h | 00h 00h | |
| Flash Duty Cycle 00h 05h | 00h 00h | |
| Good Read Delay 00h 06h | 00h 00h | |
| Light Source On Time 00h 07h | 00h 00h | |
| Hands Free Time-out 00h 08h | 00h 00h | |
| Time Delay To Low Power Mode 00h 09h | 00h 00h | |
| Trigger Control | 00h 0Ah | 00h 00h |
| Scan Rate Control | 00h 0Bh | 00h 00h |
| Buzzer Tone Adjust | 01h 00h | 00h 00h |
| Power on beep | 01h 01h | 00h 00h |
| Power on Indication | 01h 02h | 00h 00h |
| Vibrator | 01h 03h | 00h 00h |
| Good Read Duration | 01h 04h | 00h 00h |
| Good Read Indicator 01h 05h | 00h 00h | |
| 1D Barcode Inverse Reading | 02h 00h | 00h 00h |
| Dollar Sign Control | 02h 01h | 00h 00h |
| Redundancy | 02h 02h | 00h 00h |
| Data Transmission Packet | 02h 04h | 00h 00h |
| UPC/EAN Security Level | 02h 06h | 00h 00h |
| Supplement Scan Voting 02h 08h | 00h 00h | |
| Laser Aiming Control | 02h 09h | 00h 00h |
| LED Illumination | 02h 0Bh | 00h 00h |
| Illumination Delay Duration | 02h 0Ch | 00h 00h |
| Operation Mode (Tethered Scanner) | 10h 00h | 00h 00h |
| Operation Mode (Tethered A Series) | 70h 00h | 00h 00h |
| Hand-Held Mode Illumination & Aiming Control | 70h 01h | 00h 00h |
| Hand-Free Mode Decode Aiming Control | 70h 02h | 00h 00h |
| Aiming Control | 70h 03h | 00h 00h |
| Delay Aiming Timeout | 70h 04h | 00h 00h |
| Presentation Background Lighting | 70h 05h | 00h 00h |
| Center Alignment 70h 06h | 00h 00h | |
| Mobile Phone Capture | 70h 07h | 00h 00h |
| Unique Barcode Reporting | 70h 08h | 00h 00h |
Reply TS Operation (TS)
Descriptions
Reply the desired one or more parameters of the Operation Settings for Tethered Scanner Reply TS Operation is sent by the device in response to the Get TS Operation command. It sends the values for all the desired parameters requested in the Get TS Operation command. Available for F, L & A series
Packet Format
| Prefix | Opcode | Status | Length | Parameter(s) | LRC | Suffix | |||
| 7Eh | 0Ah | 00h 00h | 00h | Variable | See Below Variable | 7Eh | |||
| 1 Byte | 3 | Bytes | 1 Byte | 2 Bytes | Variable | 1 Byte | 1 Byte | ||
| Parameter(s) | |||||||||
| First Parameter | ...... | Last Parameter | |||||||
| PID | Size | Options | ...... | PID | Size | Options | |||
| 2 Bytes | 2 Bytes | Variable | ...... | 2 Bytes | 2 Bytes | Variable | |||
| See Next Page | |||||||||
| Parameter(s) | ||||||
| First Parameter | ...... | Last Parameter | ||||
| PID | Size | Options | ...... | PID | Size | Options |
| 2 Bytes | 2 Bytes | Variable | ...... | 2 Bytes | 2 Bytes | Variable |
| See Next Page | ||||||
. Host Requirements
Since Reply TS Operation is a device-to-host message, there is no response for this message.
. Parameter(s) Field
Set TS Operation can change multiple parameters at one time, so it takes compound parameters.
. Length
Total size (bytes) of the Parameter(s) field
.LRC
"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"
. Size
Total size (bytes) of the Options field
Parameter(s)
< Table 6-1-3 > Reply TS Operation Parameter(s) Field (To be continued)
| Parameter / PID / Size Options Descriptions | ||||
| Presentation ControlPID : 00h 01hSize : 00h 01h (1 Byte) | - 01h- 02h- 08h | Force modePresentation mode *Flash mode (See Notes) | ||
| Presentation Auto-sensePID : 00h 02hSize : 00h 01h (1 Byte) | - 00h- 01h | Disable *Enable | ||
| Presentation SensitivityPID : 00h 03hSize : 00h 01h (1 Byte) | - 00h- 01h- 02h- 03h | - 04h- 05h- 06h | Level 1Level 2Level 3Level 4 | Level 5 *Level 6Level 7 |
| Reread DelayPID : 00h 04hSize : 00h 01h (1 Byte) | - 00h- 01h- 02h- 03h- 04h- 05h | DisableImmediate time-out duration *Short time-out durationMedium time-out durationLong time out-durationForce Verification | ||
| Flash Duty CyclePID : 00h 05hSize : 00h 01h (1 Byte) | - 00h- 01h- 02h- 03h | 1/2 duty cycle * (See Notes)2/3 duty cycle3/4 duty cycle4/5 duty cycle | ||
| Good Read DelayPID : 00h 06hSize : 00h 01h (1 Byte) | - 00h- 01h- 02h- 03h | - 04h- 05h- 06h | None*200 ms500 ms1 s | 1.5 s2 s3 s |
| Light Source On TimePID : 00h 07hSize : 00h 01h (1 Byte) | - 00h- 01h- 02h- 03h | Short (about 2 s) *Medium (about 3~4 s)Long (about 5~6 s)Extremely Long (about 7~8 s) | ||
| Hands Free Time-outPID : 00h 08hSize : 00h 01h (1 Byte) | - 00h- 06h- 0Ah | - 0Eh- 12h | DisableShort *Medium | LongExtremely long |
| Time Delay To Low Power ModePID : 00h 09hSize : 00h 01h (1 Byte) | - 00h- 01h- 02h | - 03h- 04h- 05h | 1 s3 s5 s | 7 s9 s0 s (Immediately)* |
. Notes
Flash mode is not available for A Series.
Parameter(s)
< Table 6-1-3 > Reply TS Operation Parameter(s) Field (Continued)
| Parameter / PID / Size Options Descriptions | ||||
| Trigger Control(F460/468 only)PID: 00h 0AhSize: 00h 01h (2 Bytes) | - 00h- 01h- 02h | Enable left trigger, disable right triggerEnable right trigger, disable left triggerEnable left and right trigger * | ||
| Scan Rate ControlPID: 00h 0BhSize: 00h 01h (1 Byte) | - 00h- 01h | Dynamic *Fixed | ||
| Buzzer Tone AdjustPID: 01h 00hSize: 00h 02h (2 Bytes) | 1^st 2^nd Byte- 00h 00h- 01h 01h- 01h 02h- 01h 03h- 01h 04h | MuteLowMedium *HighExtremely High | ||
| Power on beepPID: 01h 01hSize: 00h 01h (1 Byte) | - 00h- 01h | EnableDisable | ||
| Power on IndicationPID: 01h 02hSize: 00h 01h (1 Byte) | - 00h- 01h- 02h | LED offLED steady on *LED flash | ||
| VibratorPID: 01h 03hSize: 00h 01h (1 Byte) | - 00h- 01h | DisableEnable * | ||
| Good Read DurationPID: 01h 04hSize: 00h 01h (1 Byte) | - 00h- 01h- 02h | - 03h- 04h | ShortMedium *Long | Extremely longExtremely short |
| Good Read IndicatorPID: 01h 05hSize: 00h 01h (1 Byte) | - 00h- 01h | (See Notes)DisableEnable * | ||
| 1D Barcode Inverse ReadingPID: 02h 00hSize: 00h 01h (1 Byte) | - 00h- 01h | Disable *Enable | ||
| Dollar Sign ControlPID: 02h 01hSize: 00h 01h (1 Byte) | - 00h- 80h- A2h | - A3h- A5h | Output as “$” *Output as “€” Output as “¢” | Output as “£” Output as “¥” |
| RedundancyPID: 02h 02hSize: 00h 01h (1 Byte) | - 00h- 01h- 02h | - 03h- 04h- 05h | None1 time *2 times | 3 times4 times5 times |
Notes
Good Read Indicator: If enabled, the Green LED flashes once after a good decode.
Parameter(s)
< Table 6-1-3 > Reply TS Operation Parameter(s) Field (Continued)
| Parameter / PID / Size Options Descriptions | ||||
| Data Transmission PacketPID: 02h 04hSize: 00h 01h (1 Byte) | - 00h- 01h | Disable *Enable | ||
| UPC/EAN Security LevelPID: 02h 06hSize: 00h 01h (1 Byte) | - 00h- 01h- 02h | Level 0Level 1 *Level 2 | ||
| Supplement Scan VotingPID: 02h 08hSize: 00h 01h (1 Byte) | - 00h- 06h- 08h- 0Ah- 0Ch- 0Eh- 10h | - 12h- 14h- 16h- 18h- 1Ah- 1Ch- 1Eh | NoneLevel 1Level 2Level 3 *Level 4Level 5Level 6 | Level 7Level 8Level 9Level 10Level 11Level 12Level 13 |
| Laser Aiming ControlPID: 02h 09hSize: 00h 01h (1 Byte) | - 00h- 01h | (See Notes)DisableEnable * | ||
| LED IlluminationPID: 02h 0BhSize: 00h 01h (1 Byte) | - 00h- 01h | (See Notes)Always onIntelligent Scanning * | ||
| Illumination Delay DurationPID: 02h 0ChSize: 00h 01h (1 Byte) | - 00h- 01h- 02h- 03h- 04h | (See Notes)100ms200ms300ms400ms500ms | ||
| Operation Mode(Tethered Scanner)PID: 10h 00hSize: 00h 01h (1 Byte) | - 00h- 01h- 02h- 04h- 05h- 06h- 07h- 08h- 09h | Trigger mode (External triggering) *Force mode (Continued power on)Presentation mode (Auto detection)Level mode (Auto power off)Diagnostic mode (Test reading)Alternative mode (Periodic power off)Toggle mode (Repeat reading)Flash mode (Pulse driven reading)Low Power mode (Low Power triggering) | ||
.Notes
- LED Illumination, Illumination Delay Duration are only available for L680, L688, L780, L788
- Laser Aiming Control is only available for L688, L788
Parameter(s)
< Table 6-1-3 > Reply TS Operation Parameter(s) Field (Continued)
| Parameter / PID / Size Options Descriptions | ||
| Operation Mode(Tethered A Series)PID : 70h 00hSize : 00h 03h (3 Bytes) | - 00h 01h 01h- 01h 01h 01h- 02h 01h 01h- 04h 01h 00h- 05h 01h 01h- 06h 01h 00h- 07h 01h 00h- 09h 01h 01h- 0Dh 01h 01h | Trigger mode *Force modePresentation modeLevel modeDiagnostic modeAlternative modeToggle modeLow Power modeMultiple mode |
| Hand-Held Mode Illumination & Aiming ControlPID : 70h 01hSize : 00h 01h (1 Byte) | Bit 0- 0- 1Bit 1- 0- 1 | Hand-Held Decode Aiming ControlDisableEnable *Hand-Held Illumination ControlDisableEnable * |
| Hand-Free Mode DecodeAiming ControlPID : 70h 02hSize : 00h 01h (1 Byte) | - 02h- 03h | DisableEnable * |
| Aiming ControlPID : 70h 03hSize : 00h 02h (2 Bytes) | - 00h 00h- 01h 00h- 00h 03h | Regular AimingIntelligent Aiming *Delay Aiming Control |
| Delay Aiming TimeoutControlPID : 70h 04hSize : 00h 01h (1 Byte) | - 02h- 04h- 08h- 0Ah- 0Fh- 14h- 1Eh- 28h | 200ms400ms *800ms1000ms1500ms2000ms3000ms4000ms |
| Presentation BackgroundLightingPID : 70h 05hSize : 00h 02h (2 Bytes) | - 00h 00h- 00h FFh | LEDs OffLEDs On * |
| Center AlignmentPID : 70h 06hSize : 00h 02h (2 Bytes) | 1st Byte- 00h- 01h2nd Byte- 00h- 01h | Hand-Held ModeDisable *EnableHand-Free ModeDisable *Enable |
Parameter(s)
< Table 6-1-3 > Reply TS Operation Parameter(s) Field (Continued)
| Parameter / PID / Size Options Descriptions | ||
| Mobile Phone CapturePID : 70h 07hSize : 00h 01h (1 Byte) | - 00h- 01h | Disable *Enable |
| Unique Barcode ReportingPID : 70h 08hSize : 00h 01h (1 Byte) | - 00h- 01h | Disable *Enable |
Set SE Operation (SE)
Descriptions
Change the desired one or more parameters of the Operation Settings for Scan Engine
Available for SE380, SE390 & SE480 series
Packet Format
| Prefix | Opcode | Status | Length | Parameter(s) | LRC | Suffix | ||
| 7Eh | 88h | 00h | 00h | Variable | See Below Variable | 7Eh | ||
| 1 Byte | 3 | Bytes | 1 Byte | 2 Bytes | / | Variable | 1 Byte 1 Byte | |
| Parameter(s) | ||||||
| First Parameter ...... | Last Parameter | |||||
| PID | Size | Options | ...... | PID | Size | Options |
| 2 Bytes | 2 Bytes | Variable | ...... | 2 Bytes | 2 Bytes | Variable |
| See Next Page | ||||||
. Host Requirements
If the device successfully received the above command issued by the host, a "Device ACK" will send to the host right after the device performed the action. Otherwise, a "Device NAK" will be sent to host to issue a command error. However, if the host can not receive any response from the device within the user preset time-out duration, please resend the above command.
. Parameter(s) Field
Set SE Operation can change multiple parameters at one time, so it takes compound parameters.
. Length
Total size (bytes) of the Parameter(s) field
.LRC
"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"
. Size
Total size (bytes) of the Options field
Parameter(s)
< Table 6-2-1 > Set SE Operation Parameter(s) Field (To be continued)
| Parameter / PID / Size Options Descriptions | ||||
| Presentation SensitivityPID : 00h 03hSize : 00h 01h (1 Byte) | - 00h- 01h- 02h- 03h | - 04h- 05h- 06h | Level 1Level 2Level 3Level 4 | Level 5 *Level 6Level 7 |
| Reread DelayPID : 00h 04hSize : 00h 01h (1 Byte) | - 00h- 01h- 02h- 03h- 04h- 05h | DisableImmediate time-out duration *Short time-out durationMedium time-out durationLong time out-durationForce Verification | ||
| Good Read DelayPID : 00h 06hSize : 00h 01h (1 Byte) | - 00h- 01h- 02h- 03h | - 04h- 05h- 06h | None*200 ms500 ms1 s | 1.5 s2 s3 s |
| Scan Input Time-outPID : 00h 07hSize : 00h 01h (1 Byte) | - 00h- 01h- 02h- 03h- 04h- 05h | - 06h- 07h- 08h- XXh | 100ms200ms300ms400ms500ms600ms | 700ms800ms900ms *User-defined 1-99 s:XXh = desiredseconds(h) + 80h |
| Hands Free Time-outPID : 00h 08hSize : 00h 01h (1 Byte) | - 00h- 06h- 0Ah | - 0Eh- 12h | DisableShort *Medium | LongExtremely long |
| Time Delay To Low Power ModePID : 00h 09hSize : 00h 01h (1 Byte) | - 00h- 01h- 02h | - 03h- 04h- 05h | 1 s3 s5 s | 7 s9 s0 s (Immediately)* |
| Scan Rate ControlPID : 00h 0BhSize : 00h 01h (1 Byte) | - 00h- 01h | Dynamic *Fixed | ||
| Buzzer Tone AdjustPID : 01h 00hSize : 00h 02h (2 Bytes) | 1^st 2^nd Byte- 00h 00h- 01h 01h- 01h 02h- 01h 03h- 01h 04h | MuteLowMedium *HighExtremely High | ||
| Power on beepPID : 01h 01hSize : 00h 01h (1 Byte) | - 00h- 01h | Enable (SE380/SE388-9 *)Disable (SE380/SE388-0, SE380/SE388-1 *) | ||
Parameter(s)
< Table 6-2-1 > Set SE Operation Parameter(s) Field (Continued)
| Parameter / PID / Size Options Descriptions | ||||
| Good Read DurationPID: 01h 04hSize: 00h 01h (1 Byte) | - 00h- 01h- 02h | - 03h- 04h | ShortMedium *Long | Extremely longExtremely short |
| Good Read IndicatorPID: 01h 05hSize: 00h 01h (1 Byte) | - 00h- 01h | Disable(SE380-0,SE380-1,SE390-0,SE390-1,SE480-0, SE480-1*)Enable(SE380-9,SE390-9, SE480-9 *) | ||
| 1D Barcode Inverse ReadingPID: 02h 00hSize: 00h 01h (1 Byte) | - 00h- 01h | Disable *Enable | ||
| Dollar Sign ControlPID: 02h 01hSize: 00h 01h (1 Byte) | - 00h- 80h- A2h | - A3h- A5h | Output as "$" *Output as "€"Output as "¢" | Output as "£"Output as "¥" |
| RedundancyPID: 02h 02hSize: 00h 01h (1 Byte) | - 00h- 01h- 02h | - 03h- 04h- 05h | None1 time *2 times | 3 times4 times5 times |
| Data Transmission PacketPID: 02h 04hSize: 00h 01h (1 Byte) | - 00h- 01h | Disable *Enable | ||
| UPC/EAN Security LevelPID: 02h 06hSize: 00h 01h (1 Byte) | - 00h- 01h | - 02h | Level 0Level 1 * | Level 2 |
| Supplement Scan VotingPID: 02h 08hSize: 00h 01h (1 Byte) | - 00h- 06h- 08h- 0Ah- 0Ch- 0Eh- 10h | - 12h- 14h- 16h- 18h- 1Ah- 1Ch- 1Eh | NoneLevel 1Level 2Level 3 *Level 4Level 5Level 6 | Level 7Level 8Level 9Level 10Level 11Level 12Level 13 |
| Operation Mode (Scan Engine)PID: 30h 00hSize: 00h 01h (1 Byte) | - 00h- 01h- 02h- 04h- 06h- 09h | Trigger mode (External triggering) *Force mode (Continued power on) (See Note)Presentation mode (Auto Detection)Level mode (Auto power off)Alternative mode (Periodic power off)Low Power mode (Low Power triggering) | ||
| I/O Active StatePID: 30h 01hSize: 00h 01h (1 Byte) | - 00h- 01h | HighLow * | ||
. Note
Force mode is not available for SE390 and SE480 series.
Parameter(s)
< Table 6-2-1 > Set SE Operation Parameter(s) Field (Continued)
| Parameter / PID / Size Options Descriptions | ||
| Laser Aiming Control | ||
| PID : 02h 09h | - 00h | Disable |
| Size : 00h 01h (1 Byte) | - 01h | Enable * |
| LED Illumination | (See Note) | |
| PID : 02h 0Bh | - 00h | Always on |
| Size : 00h 01h (1 Byte) | - 01h | Intelligent Scanning * |
| Illumination Delay Duration | (See Note) | |
| PID : 02h 0Ch | - 00h | 100ms |
| Size : 00h 01h (1 Byte) | - 01h | 200ms |
| - 02h | 300ms | |
| - 03h | 400ms | |
| - 04h | 500ms | |
. Warning
- LED Illumination, Illumination Delay Duration are only available for SE390 and SE480 series.
- Laser Aiming Control is only available for SE398 and SE488
Get SE Operation (SE)
Descriptions
Request the desired one or more parameters of the Operation Settings for Scan Engine
Available for SE380, SE390 & SE480 series
Packet Format
| Prefix | Opcode | Status | Length | Parameter(s) | LRC | Suffix | |||
| 7Eh | C9h | 00h | 00h | Variable | See Below | Variable | 7Eh | ||
| 1 Byte | 3 | Bytes | 1 Byte | 2 Bytes | Variable | 1 Byte | 1 Byte | ||
| Parameter(s) | |||||||||
| First Parameter | ...... | Last Parameter | |||||||
| PID Size ...... | PID Size | ||||||||
| 2 Bytes | 2 Bytes | ...... | 2 Bytes | 2 Bytes | |||||
| See Next Page | |||||||||
. Host Requirements
If the device successfully received the above command issued by the host, the device will pack all requested parameters into a "Reply SE Operation" message string then send to the host. Please refer to the "Reply SE Operation" command for details. Otherwise, a "Device NAK" will be sent to host to indicate issue a command error. However, if the host can receive any response from the device within the user preset time-out duration, please resend the above command.
. Parameter(s) Field
Get SE Operation can request multiple parameters at one time, so it takes compound parameters.
. Length
Total size (bytes) of the Parameter(s) field
.LRC
"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"
. Size
Total size (bytes) of the Options field
Parameter(s)
< Table 6-2-2 > Get SE Operation Parameter(s) Field
| Parameter PID Size | ||
| Presentation Sensitivity 00h 03h | 00h 00h | |
| Reread Delay 00h 04h | 00h 00h | |
| Good Read Delay 00h 06h | 00h 00h | |
| Scan Input Time-out 00h 07h | 00h 00h | |
| Hands Free Time-out 00h 08h | 00h 00h | |
| Time Delay To Low Power Mode 00h 09h | 00h 00h | |
| Scan Rate Control 00h 0Bh | 00h 00h | |
| Buzzer Tone Adjust 01h 00h | 00h 00h | |
| Power on beep 01h 01h | 00h 00h | |
| Good Read Duration 01h 04h | 00h 00h | |
| Good Read Indicator 01h 05h | 00h 00h | |
| 1D Barcode Inverse Reading | 02h 00h | 00h 00h |
| Dollar Sign Control | 02h 01h | 00h 00h |
| Redundancy | 02h 02h | 00h 00h |
| Data Transmission Packet | 02h 04h | 00h 00h |
| UPC/EAN Security Level | 02h 06h | 00h 00h |
| Supplement Scan Voting | 02h 08h | 00h 00h |
| Operation Mode (Scan Engine) | 30h 00h | 00h 00h |
| I/O Active State | 30h 01h | 00h 00h |
| Laser Aiming Control | 02h 09h | 00h 00h |
| LED Illumination | 02h 0Bh | 00h 00h |
| Illumination Delay Duration | 02h 0Ch | 00h 00h |
Reply SE Operation (SE)
Descriptions
Reply the desired one or more parameters of the Operation Settings for Scan Engine Reply SE Operation is sent by the device in response to the Get SE Operation command. It sends the values for all the desired parameters requested in the Get SE Operation command. Available for SE380, SE390 & SE480 series
Packet Format
| Prefix | Opcode | Status | Length | Parameter(s) | LRC | Suffix | |||
| 7Eh | 0Ah | 00h | 00h | Variable | See Below | Variable | 7Eh | ||
| 1 Byte | 3 | Bytes | 1 Byte | 2 Bytes | Variable | 1 Byte | 1 Byte | ||
| Parameter(s) | |||||||||
| First Parameter | ...... | Last Parameter | |||||||
| PID | Size | Options | ...... | PID | Size | Options | |||
| 2 Bytes | 2 Bytes | Variable | ...... | 2 Bytes | 2 Bytes | Variable | |||
| See Next Page | |||||||||
| Parameter(s) | ||||||
| First Parameter | ...... | Last Parameter | ||||
| PID | Size | Options | ...... | PID | Size | Options |
| 2 Bytes | 2 Bytes | Variable | ...... | 2 Bytes | 2 Bytes | Variable |
| See Next Page | ||||||
. Host Requirements
Since Reply SE Operation is a device-to-host message, there is no response for this message.
. Parameter(s) Field
Set SE Operation can change multiple parameters at one time, so it takes compound parameters.
. Length
Total size (bytes) of the Parameter(s) field
.LRC
"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"
. Size
Total size (bytes) of the Options field
Parameter(s)
< Table 6-2-3 > Reply SE Operation Parameter(s) Field (To be continued)
| Parameter / PID / Size Options Descriptions | ||||
| Presentation SensitivityPID : 00h 03hSize : 00h 01h (1 Byte) | - 00h- 01h- 02h- 03h | - 04h- 05h- 06h | Level 1Level 2Level 3Level 4 | Level 5 *Level 6Level 7 |
| Reread DelayPID : 00h 04hSize : 00h 01h (1 Byte) | - 00h- 01h- 02h- 03h- 04h- 05h | DisableImmediate time-out duration *Short time-out durationMedium time-out durationLong time out-durationForce Verification | ||
| Good Read DelayPID : 00h 06hSize : 00h 01h (1 Byte) | - 00h- 01h- 02h- 03h | - 04h- 05h- 06h | None*200 ms500 ms1 s | 1.5 s2 s3 s |
| Scan Input Time-outPID : 00h 07hSize : 00h 01h (1 Byte) | - 00h- 01h- 02h- 03h- 04h- 05h | - 06h- 07h- 08h- XXh | 100ms200ms300ms400ms500ms600ms | 700ms800ms900ms *User-defined 1-99 s:XXh = desiredseconds(h) + 80h |
| Hands Free Time-outPID : 00h 08hSize : 00h 01h (1 Byte) | - 00h- 06h- 0Ah | - 0Eh- 12h | DisableShort *Medium | LongExtremely long |
| Time Delay To Low Power ModePID : 00h 09hSize : 00h 01h (1 Byte) | - 00h- 01h- 02h | - 03h- 04h- 05h | 1 s3 s5 s | 7 s9 s0 s (Immediately)* |
| Scan Rate ControlPID : 00h 0BhSize : 00h 01h (1 Byte) | - 00h- 01h | Dynamic *Fixed | ||
| Buzzer Tone AdjustPID : 01h 00hSize : 00h 02h (2 Bytes) | 1^st 2^nd Byte- 00h 00h- 01h 01h- 01h 02h- 01h 03h- 01h 04h | MuteLowMedium *HighExtremely High | ||
Parameter(s)
< Table 6-2-3 > Reply SE Operation Parameter(s) Field (Continued)
| Parameter / PID / Size Options Descriptions | ||||
| Power on beepPID : 01h 01hSize : 00h 01h (1 Byte) | - 00h- 01h | Enable (SE380/SE388-9 *)Disable (SE380/SE388-0, SE380/SE388-1 *) | ||
| Good Read DurationPID : 01h 04hSize : 00h 01h (1 Byte) | - 00h- 01h- 02h | - 03h- 04h | ShortMedium *Long | Extremely longExtremely short |
| Good Read IndicatorPID : 01h 05hSize : 00h 01h (1 Byte) | - 00h- 01h | Disable(SE380-0,SE380-1,SE390-0,SE390-1,SE480-0, SE480-1*)Enable(SE380-9,SE390-9, SE480-9 *) | ||
| 1D Barcode Inverse ReadingPID : 02h 00hSize : 00h 01h (1 Byte) | - 00h- 01h | Disable *Enable | ||
| Dollar Sign ControlPID : 02h 01hSize : 00h 01h (1 Byte) | - 00h- 80h- A2h | - A3h- A5h | Output as “$” *Output as “€”Output as “¢” | Output as “£”Output as “¥” |
| RedundancyPID : 02h 02hSize : 00h 01h (1 Byte) | - 00h- 01h- 02h | - 03h- 04h- 05h | None1 time *2 times | 3 times4 times5 times |
| Data Transmission PacketPID : 02h 04hSize : 00h 01h (1 Byte) | - 00h- 01h | Disable *Enable | ||
| UPC/EAN Security LevelPID : 02h 06hSize : 00h 01h (1 Byte) | - 00h- 01h- 02h | Level 0Level 1 *Level 2 | ||
| Supplement Scan VotingPID : 02h 08hSize : 00h 01h (1 Byte) | - 00h- 06h- 08h- 0Ah- 0Ch- 0Eh- 10h | - 12h- 14h- 16h- 18h- 1Ah- 1Ch- 1Eh | NoneLevel 1Level 2Level 3 *Level 4Level 5Level 6 | Level 7Level 8Level 9Level 10Level 11Level 12Level 13 |
| Operation Mode (Scan Engine)PID : 30h 00hSize : 00h 01h (1 Byte) | - 00h- 01h- 02h- 04h- 06h- 09h | Trigger mode (External triggering) *Force mode (Continued power on)Presentation mode (Auto Detection)Level mode (Auto power off)Alternative mode (Periodic power off)Low Power mode (Low Power triggering) | ||
| I/O Active StatePID : 30h 01hSize : 00h 01h (1 Byte) | - 00h- 01h | HighLow * | ||
Parameter(s)
< Table 6-2-3 > Reply SE Operation Parameter(s) Field (Continued)
| Parameter / PID / Size Options Descriptions | ||
| Laser Aiming Control | ||
| PID : 02h 09h | - 00h | Disable |
| Size : 00h 01h (1 Byte) | - 01h | Enable * |
| LED Illumination | ||
| PID : 02h 0Bh | - 00h | Always on |
| Size : 00h 01h (1 Byte) | - 01h | Intelligent Scanning * |
| Illumination Delay Duration | ||
| PID : 02h 0Ch | - 00h | 100ms |
| Size : 00h 01h (1 Byte) | - 01h | 200ms |
| - 02h | 300ms | |
| - 03h | 400ms | |
| - 04h | 500ms | |
. Warning
- LED Illumination, Illumination Delay Duration are only available for SE390 and SE480 series.
- Laser Aiming Control is only available for SE398 and SE488
Set FS Operation (FS)
Descriptions
Change the desired one or more parameters of the Operation Settings for Fixed Mount and Scan Module
Available for FM480, FA470, SM380 & SM5700 series
Packet Format
| Prefix | Opcode | Status | Length | Parameter(s) | LRC | Suffix | |||
| 7Eh | 88h | 00h | 00h | Variable | See Below | Variable | 7Eh | ||
| 1 Byte | 3 | Bytes | 1 Byte | 2 Bytes | Variable | 1 Byte | 1 Byte | ||
| Parameter(s) | |||||||||
| First Parameter | ...... | Last Parameter | |||||||
| PID | Size | Options | ...... | PID | Size | Options | |||
| 2 Bytes | 2 Bytes | Variable | ...... | 2 Bytes | 2 Bytes | Variable | |||
| See Next Page | |||||||||
. Host Requirements
If the device successfully received the above command issued by the host, a "Device ACK" will send to the host right after the device performed the action. Otherwise, a "Device NAK" will be sent to host to issue a command error. However, if the host can not receive any response from the device within the user preset time-out duration, please resend the above command.
. Parameter(s) Field
Set FS Operation can change multiple parameters at one time, so it takes compound parameters.
. Length
Total size (bytes) of the Parameter(s) field
.LRC
"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"
. Size
Total size (bytes) of the Options field
Parameter(s)
< Table 6-3-1 > Set FS Operation Parameter(s) Field (To be continued)
| Parameter / PID / Size Options Descriptions | ||||
| Presentation SensitivityPID : 00h 03hSize : 00h 01h (1 Byte) | - 00h- 01h- 02h- 03h | - 04h- 05h- 06h | Level 1Level 2Level 3Level 4 | Level 5 *Level 6Level 7 |
| Reread DelayPID : 00h 04hSize : 00h 01h (1 Byte) | - 00h- 01h- 02h- 03h- 04h- 05h | DisableImmediate time-out duration *Short time-out durationMedium time-out durationLong time out-durationForce Verification | ||
| Good Read DelayPID : 00h 06hSize : 00h 01h (1 Byte) | - 00h- 01h- 02h- 03h | - 04h- 05h- 06h | None*200 ms500 ms1 s | 1.5 s2 s3 s |
| Hands Free Time-outPID : 00h 08hSize : 00h 01h (1 Byte) | - 00h- 06h- 0Ah | - 0Eh- 12h | DisableShort *Medium | LongExtremely long |
| Scan Rate ControlPID : 00h 0BhSize : 00h 01h (1 Byte) | - 00h- 01h | (See Notes)Dynamic *Fixed | ||
| Buzzer Tone AdjustPID : 01h 00hSize : 00h 02h (2 Bytes) | 1^st 2^nd Byte- 00h 00h- 01h 01h- 01h 02h- 01h 03h- 01h 04h | MuteLowMedium *HighExtremely High | ||
| Power on beepPID : 01h 01hSize : 00h 01h (1 Byte) | - 00h- 01h | Enable *Disable | ||
| Power on IndicationPID : 01h 02hSize : 00h 01h (1 Byte) | - 00h- 01h- 02h | LED OffLED On *LED Flash | ||
| Good Read DurationPID : 01h 04hSize : 00h 01h (1 Byte) | - 00h- 01h- 02h | - 03h- 04h | ShortMedium *Long | Extremely longExtremely short |
. Note
Scan Rate Control is available for FM480 & SM380 only.
Parameter(s)
< Table 6-3-1 > Set FS Operation Parameter(s) Field (Continued)
| Parameter / PID / Size Options Descriptions | ||||
| 1D Barcode Inverse ReadingPID: 02h 00hSize: 00h 01h (1 Byte) | - 00h- 01h | Disable *Enable | ||
| Dollar Sign ControlPID: 02h 01hSize: 00h 01h (1 Byte) | - 00h- 80h- A2h | - A3h- A5h | Output as “” *Output as “€”Output as “¢” | Output as “£”Output as “¥” |
| RedundancyPID: 02h 02hSize: 00h 01h (1 Byte) | - 00h- 01h- 02h | - 03h- 04h- 05h | None1 time *2 times | 3 times4 times5 times |
| Data Transmission PacketPID: 02h 04hSize: 00h 01h (1 Byte) | - 00h- 01h | Disable *Enable | ||
| UPC/EAN Security LevelPID: 02h 06hSize: 00h 01h (1 Byte) | - 00h- 01h- 02h | Level 0Level 1 *Level 2 | ||
| Supplement Scan VotingPID: 02h 08hSize: 00h 01h (1 Byte) | - 00h- 06h- 08h- 0Ah- 0Ch- 0Eh- 10h | - 12h- 14h- 16h- 18h- 1Ah- 1Ch- 1Eh | NoneLevel 1Level 2Level 3 *Level 4Level 5Level 6 | Level 7Level 8Level 9Level 10Level 11Level 12Level 13 |
| Operation Mode(FM480 & SM380 series)PID: 20h 00hSize: 00h 01h (1 Byte) | - 00h- 01h- 02h- 04h- 06h | Trigger mode (External triggering) *Force mode (Continued power on)Presentation mode (Auto Detection)Level mode (Auto power off)Alternative mode (Periodic power off) | ||
| NG Message OutputPID: 20h 04hSize: 00h 10h (16 Bytes) | 1^{st} \sim 16^{th}$ Byte- 00h 00h...00h- 02h 4Eh 47h00h...00h- XXh XXh...XXh | Disable * (Totally sixteen “00h”s)Output “NG” (Totally thirteen “00h”s)(See Note under the table)Output User-defined message | ||
. Note
NG Message Output carries 16 bytes in the Options Field. The 1st byte which indicates the length of the message is followed by the message characters. If the desired ASCII characters for setting the message are shorter than 15 bytes, the rest bytes should be set to 00h. For example, to output "BAD", the 1st byte is 03h (length of "BAD"), the 2^nd to 4^th byte is 42h 41h 44h (ASCII value of "BAD"), and from the 5^th byte to the 16^th byte are all 00h.
Parameter(s)
< Table 5-3 > Set FS Operation Parameter(s) Field (Continued)
| Parameter / PID / Size Options Descriptions | ||
| OK/NG Active Signal ControlPID : 20h 01hSize : 00h 03h (3 Bytes) | 1^st Byte- 00h- 01h- 02h- 03h 2^nd Byte- 00h- 01h- 02h- 03h 3^rd Byte- 01h- 02h- 03h- 04h- 05h- 06h- 07h- 08h- 09h- 0Ah- XXh | OK/NG Active Signal OutputDisableEnable NG onlyEnable OK onlyEnable*OK/NG Active Signal StateOK Low/ NG Low*OK Low/ NG HighOK High/ NG LowOK High/ NG HighOK/NG Active Duration10ms20ms30ms40ms50ms60ms70ms80ms90ms100ms *User-defined (See Note under the table) |
| OK/NG Beep ControlPID : 20h 02hSize : 00h 02h (2 Bytes) | 1^st 2^nd Byte- 00h 00h- 01h 01h- 00h 01h- 01h 00h | DisableEnable *Enable OK onlyEnable NG only |
| Scan Input Time-outPID : 20h 03hSize : 00h 01h (1 Byte) | - 00h- 01h- 02h- 03h- 04h- 05h- 06h- 07h- 08h- XXh | 100ms200ms300ms400ms500ms600ms700ms800ms900ms*User-defined (See Note under the table) |
. Notes
- OK/ NG Active Duration can be set to User-defined 1\~99(×5) milliseconds. XXh = desired milliseconds (h) + 80h. For example, if you want to set it to 99 (×5) ms (the actual value is 495 ms), you need to convert 99 from Dec to Hex, that is, 63h. Then, XXh = 63h + 80h = E3h.
- Scan Input Time-out can be set to User-defined 1\~99 seconds. XXh = desired seconds (h) + 80h. For example, if you want to set this parameter to 99 seconds, you need to convert 99 from Dec to Hex, that is, 63h. Then, XXh = 63h + 80h = E3h.
Parameter(s)
< Table 5-3 > Set FS Operation Parameter(s) Field (Continued)
| Parameter / PID / Size Options Descriptions | ||
| Operation Mode(FA470 & SM5700 series)PID : 70h 00hSize : 00h 03h (3 Bytes) | - 00h 01h 01h- 01h 01h 01h- 02h 01h 01h- 04h 01h 00h- 06h 01h 00h | (See Notes)Trigger mode *Force modePresentation modeLevel modeAlternative mode |
| Hand-Held Mode Illumination& Aiming ControlPID : 70h 01hSize : 00h 01h (1 Byte) | Bit 0- 0- 1Bit 1- 0- 1 | Hand-Held Decode Aiming ControlDisableEnable *Hand-Held Illumination ControlDisableEnable * |
| Hand-Free Mode DecodeAiming ControlPID : 70h 02hSize : 00h 01h (1 Byte) | - 02h- 03h | (See Notes)DisableEnable * |
| Aiming ControlPID : 70h 03hSize : 00h 02h (2 Bytes) | - 00h 00h- 01h 00h- 00h 03h | (See Notes)Regular AimingIntelligent Aiming *Delay Aiming Control |
| Delay Aiming TimeoutControlPID : 70h 04hSize : 00h 01h (1 Byte) | - 02h- 04h- 08h- 0Ah- 0Fh- 14h- 1Eh- 28h | (See Notes)200ms400ms *800ms1000ms1500ms2000ms3000ms4000ms |
| Presentation BackgroundLightingPID : 70h 05hSize : 00h 02h (2 Bytes) | - 00h 00h- 00h FFh | (See Notes)LEDs OffLEDs On * |
| Center AlignmentPID : 70h 06hSize : 00h 02h (2 Bytes) | 1st Byte- 00h- 01h2nd Byte- 00h- 01h | (See Notes)Hand-Held ModeDisable *EnableHand-Free ModeDisable *Enable |
| Mobile Phone CapturePID : 70h 07hSize : 00h 01h (1 Byte) | - 00h- 01h | (See Notes)Disable *Enable |
. Note
Hand-Held Mode Illumination & Aiming Control, Hand-Free Mode Decode Aiming Control, Aiming Control, Delay Aiming Timeout, Presentation Background Lighting, Center Alignment and Mobile Phone Capture are available for FA470 & SM5700 only.
Get FS Operation (FS)
Descriptions
Request the desired one or more parameters of the Operation Settings for Fixed Mount and Scan Module
Available for FM480, FA470, SM380 & SM5700 series
Packet Format
| Prefix | Opcode | Status | Length | Parameter(s) | LRC | Suffix | |||
| 7Eh | C9h 00h 00h | 00h | Variable | See Below Variable | 7Eh | ||||
| 1 Byte | 3 | Bytes | 1 Byte | 2 Bytes | Variable | 1 Byte | 1 Byte | ||
| Parameter(s) | |||||||||
| First Parameter | ...... | Last Parameter | |||||||
| PID Size | ...... | PID Size | |||||||
| 2 Bytes | 2 Bytes | ...... | 2 Bytes | 2 Bytes | |||||
| See Next Page | |||||||||
. Host Requirements
If the device successfully received the above command issued by the host, the device will pack all requested parameters into a "Reply FS Operation" message string then send to the host. Please refer to the "Reply FS Operation" command for details. Otherwise, a "Device NAK" will be sent to host to indicate issue a command error. However, if the host can receive any response from the device within the user preset time-out duration, please resend the above command.
. Parameter(s) Field
Get FS Operation can request multiple parameters at one time, so it takes compound parameters.
.Length
Total size (bytes) of the Parameter(s) field
.LRC
"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"
. Size
Total size (bytes) of the Options field
Parameter(s)
< Table 6-3-2 > Get FS Operation Parameter(s) Field
| Parameter PID Size | ||
| Presentation Sensitivity 00h 03h | 00h 00h | |
| Reread Delay 00h 04h | 00h 00h | |
| Good Read Delay 00h 06h | 00h 00h | |
| Hands Free Time-out 00h 08h | 00h 00h | |
| Scan Rate Control 00h 0Bh | 00h 00h | |
| Buzzer Tone Adjust 01h 00h | 00h 00h | |
| Power on beep 01h 01h | 00h 00h | |
| Power on Indication 01h 02h | 00h 00h | |
| Good Read Duration 01h 04h | 00h 00h | |
| 1D Barcode Inverse Reading 02h 00h | 00h 00h | |
| Dollar Sign Control | 02h 01h | 00h 00h |
| Redundancy | 02h 02h | 00h 00h |
| Data Transmission Packet | 02h 04h | 00h 00h |
| UPC/EAN Security Level | 02h 06h | 00h 00h |
| Supplement Scan Voting | 02h 08h | 00h 00h |
| Operation Mode(FM480 & SM380 series) | 20h 00h | 00h 00h |
| NG Message Output | 20h 04h | 00h 00h |
| OK/NG Active Signal Control | 20h 01h | 00h 00h |
| OK/NG Beep Control | 20h 02h | 00h 00h |
| Scan Input Time-out | 20h 03h | 00h 00h |
| Operation Mode (FA470 & SM5700 series) 70h 00h | 00h 00h | |
| Hand-Held Mode Illumination & Aiming Control | 70h 01h | 00h 00h |
| Hand-Free Mode Decode Aiming Control | 70h 02h | 00h 00h |
| Aiming Control | 70h 03h | 00h 00h |
| Delay Aiming Timeout | 70h 04h | 00h 00h |
| Presentation Background Lighting | 70h 05h | 00h 00h |
| Center Alignment 70h 06h | 00h 00h | |
| Mobile Phone Capture | 70h 07h | 00h 00h |
Reply FS Operation (FS)
Descriptions
Reply the desired one or more parameters of the Operation Settings for Fixed Mount and Scan Module
Reply FS Operation is sent by the device in response to the Get FS Operation command. It sends the values for all the desired parameters requested in the Get FS Operation command.
Available for FM480, FA470, SM380 & SM5700 series
Packet Format
| Prefix | Opcode | Status | Length | Parameter(s) | LRC | Suffix | |||
| 7Eh | 0Ah | 00h | 00h | Variable | See Below | Variable | 7Eh | ||
| 1 Byte | 3 | Bytes | 1 Byte | 2 Bytes | Variable | 1 Byte | 1 Byte | ||
| Parameter(s) | |||||||||
| First Parameter | ...... | Last Parameter | |||||||
| PID | Size | Options | ...... | PID | Size | Options | |||
| 2 Bytes | 2 Bytes | Variable | ...... | 2 Bytes | 2 Bytes | Variable | |||
| See Next Page | |||||||||
. Host Requirements
Since Reply FS Operation is a device-to-host message, there is no response for this message.
. Parameter(s) Field
Set FS Operation can change multiple parameters at one time, so it takes compound parameters.
. Length
Total size (bytes) of the Parameter(s) field
.LRC
"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"
. Size
Total size (bytes) of the Options field
Parameter(s)
< Table 6-3-3 > Reply FS Operation Parameter(s) Field (To be continued)
| Parameter / PID / Size Options Descriptions | ||||
| Presentation SensitivityPID : 00h 03hSize : 00h 01h (1 Byte) | - 00h- 01h- 02h- 03h | - 04h- 05h- 06h | Level 1Level 2Level 3Level 4 | Level 5 *Level 6Level 7 |
| Reread DelayPID : 00h 04hSize : 00h 01h (1 Byte) | - 00h- 01h- 02h- 03h- 04h- 05h | DisableImmediate time-out duration *Short time-out durationMedium time-out durationLong time out-durationForce Verification | ||
| Good Read DelayPID : 00h 06hSize : 00h 01h (1 Byte) | - 00h- 01h- 02h- 03h | - 04h- 05h- 06h | None*200 ms500 ms1 s | 1.5 s2 s3 s |
| Hands Free Time-outPID : 00h 08hSize : 00h 01h (1 Byte) | - 00h- 06h- 0Ah | - 0Eh- 12h | DisableShort *Medium | LongExtremely long |
| Scan Rate ControlPID : 00h 0BhSize : 00h 01h (1 Byte) | - 00h- 01h | (See Notes)Dynamic *Fixed | ||
| Buzzer Tone AdjustPID : 01h 00hSize : 00h 02h (2 Bytes) | 1^st 2^nd Byte- 00h 00h- 01h 01h- 01h 02h- 01h 03h- 01h 04h | MuteLowMedium *HighExtremely High | ||
| Power on beepPID : 01h 01hSize : 00h 01h (1 Byte) | - 00h- 01h | Enable *Disable | ||
| Power on IndicationPID : 01h 02hSize : 00h 01h (1 Byte) | - 00h- 01h- 02h | LED OffLED On *LED Flash | ||
| Good Read DurationPID : 01h 04hSize : 00h 01h (1 Byte) | - 00h- 01h- 02h | - 03h- 04h | ShortMedium *Long | Extremely longExtremely short |
. Note
Scan Rate Control is available for FM480 & SM380 only.
Parameter(s)
< Table 6-3-3 > Reply FS Operation Parameter(s) Field (Continued)
| Parameter / PID / Size Options Descriptions | ||||
| 1D Barcode Inverse ReadingPID: 02h 00hSize: 00h 01h (1 Byte) | - 00h- 01h | Disable *Enable | ||
| Dollar Sign ControlPID: 02h 01hSize: 00h 01h (1 Byte) | - 00h- 80h- A2h | - A3h- A5h | Output as “” *Output as “€”Output as “¢” | Output as “£”Output as “¥” |
| RedundancyPID: 02h 02hSize: 00h 01h (1 Byte) | - 00h- 01h- 02h | - 03h- 04h- 05h | None1 time *2 times | 3 times4 times5 times |
| Data Transmission PacketPID: 02h 04hSize: 00h 01h (1 Byte) | - 00h- 01h | Disable *Enable | ||
| UPC/EAN Security LevelPID: 02h 06hSize: 00h 01h (1 Byte) | - 00h- 01h- 02h | Level 0Level 1 *Level 2 | ||
| Supplement Scan VotingPID: 02h 08hSize: 00h 01h (1 Byte) | - 00h- 06h- 08h- 0Ah- 0Ch- 0Eh- 10h | - 12h- 14h- 16h- 18h- 1Ah- 1Ch- 1Eh | NoneLevel 1Level 2Level 3 *Level 4Level 5Level 6 | Level 7Level 8Level 9Level 10Level 11Level 12Level 13 |
| Operation Mode(FM480 & SM380 series)PID: 20h 00hSize: 00h 01h (1 Byte) | - 00h- 01h- 02h- 04h- 06h | Trigger mode (External triggering) *Force mode (Continued power on)Presentation mode (Auto Detection)Level mode (Auto power off)Alternative mode (Periodic power off) | ||
| NG Message OutputPID: 20h 04hSize: 00h 10h (16 Bytes) | 1^{st} \sim 16^{th}$ Byte- 00h 00h...00h- 02h 4Eh 47h00h...00h- XXh XXh...XXh | Disable * (Totally sixteen “00h”s)Output “NG” (Totally thirteen “00h”s)(See Note under the table)Output User-defined message | ||
. Note
NG Message Output carries 16 bytes in the Options Field. The 1st byte which indicates the length of the message is followed by the message characters. If the desired ASCII characters for setting the message are shorter than 15 bytes, the rest bytes should be set to 00h. For example, to output "BAD", the 1st byte is 03h (length of "BAD"), the 2^nd to 4^th byte is 42h 41h 44h (ASCII value of "BAD"), and from the 5^th byte to the 16^th byte are all 00h.
Parameter(s)
< Table 6-3-3 > Reply FS Operation Parameter(s) Field (Continued)
| Parameter / PID / Size Options Descriptions | ||
| OK/NG Active Signal ControlPID : 20h 01hSize : 00h 03h (3 Bytes) | 1^st Byte- 00h- 01h- 02h- 03h 2^nd Byte- 00h- 01h- 02h- 03h 3^rd Byte- 01h- 02h- 03h- 04h- 05h- 06h- 07h- 08h- 09h- 0Ah- XXh | OK/NG Active Signal OutputDisableEnable NG onlyEnable OK onlyEnable*OK/NG Active Signal StateOK Low/ NG Low*OK Low/ NG HighOK High/ NG LowOK High/ NG HighOK/NG Active Duration10ms20ms30ms40ms50ms60ms70ms80ms90ms100ms *User-defined (See Note under the table) |
| OK/NG Beep ControlPID : 20h 02hSize : 00h 02h (2 Bytes) | 1^st 2^nd Byte- 00h 00h- 01h 01h- 00h 01h- 01h 00h | DisableEnable *Enable OK onlyEnable NG only |
| Scan Input Time-outPID : 20h 03hSize : 00h 01h (1 Byte) | - 00h- 01h- 02h- 03h- 04h- 05h- 06h- 07h- 08h- XXh | 100ms200ms300ms400ms500ms600ms700ms800ms900ms*User-defined (See Note under the table) |
.Notes
- OK/ NG Active Duration can be set to User-defined 1\~99(×5) milliseconds. XXh = desired milliseconds (h) + 80h. For example, if you want to set it to 99 (×5) ms (the actual value is 495 ms), you need to convert 99 from Dec to Hex, that is, 63h. Then, XXh = 63h + 80h = E3h.
- Scan Input Time-out can be set to User-defined 1\~99 seconds. XXh = desired seconds (h) + 80h. For example, if you want to set this parameter to 99 seconds, you need to convert 99 from Dec to Hex, that is, 63h. Then, XXh = 63h + 80h = E3h.
Parameter(s)
< Table 6-3-3 > Reply FS Operation Parameter(s) Field (Continued)
| Parameter / PID / Size Options Descriptions | ||
| Operation Mode(FA470 & SM5700 series)PID : 70h 00hSize : 00h 03h (3 Bytes) | - 00h 01h 01h- 01h 01h 01h- 02h 01h 01h- 04h 01h 00h- 06h 01h 00h | (See Notes)Trigger mode *Force modePresentation modeLevel modeAlternative mode |
| Hand-Held Mode Illumination& Aiming ControlPID : 70h 01hSize : 00h 01h (1 Byte) | Bit 0- 0- 1Bit 1- 0- 1 | Hand-Held Decode Aiming ControlDisableEnable *Hand-Held Illumination ControlDisableEnable * |
| Hand-Free Mode DecodeAiming ControlPID : 70h 02hSize : 00h 01h (1 Byte) | - 02h- 03h | (See Notes)DisableEnable * |
| Aiming ControlPID : 70h 03hSize : 00h 02h (2 Bytes) | - 00h 00h- 01h 00h- 00h 03h | (See Notes)Regular AimingIntelligent Aiming *Delay Aiming Control |
| Delay Aiming TimeoutControlPID : 70h 04hSize : 00h 01h (1 Byte) | - 02h- 04h- 08h- 0Ah- 0Fh- 14h- 1Eh- 28h | (See Notes)200ms400ms *800ms1000ms1500ms2000ms3000ms4000ms |
| Presentation BackgroundLightingPID : 70h 05hSize : 00h 02h (2 Bytes) | - 00h 00h- 00h FFh | (See Notes)LEDs OffLEDs On * |
| Center AlignmentPID : 70h 06hSize : 00h 02h (2 Bytes) | 1st Byte- 00h- 01h2nd Byte- 00h- 01h | (See Notes)Hand-Held ModeDisable *EnableHand-Free ModeDisable *Enable |
| Mobile Phone CapturePID : 70h 07hSize : 00h 01h (1 Byte) | - 00h- 01h | (See Notes)Disable *Enable |
. Note
Hand-Held Mode Illumination & Aiming Control, Hand-Free Mode Decode Aiming Control, Aiming Control, Delay Aiming Timeout, Presentation Background Lighting, Center Alignment and Mobile Phone Capture are available for FA470 & SM5700 only.
Set BT Operation (BT)
Descriptions
Change the desired one or more parameters of the Operation Settings for Bluetooth Scanner Available for F, L & A series
Packet Format
| Prefix | Opcode | Status | Length | Parameter(s) | LRC | Suffix | ||
| 7Eh | 88h | 00h | 00h | Variable | See Below Variable | 7Eh | ||
| 1 Byte | 3 | Bytes | 1 Byte | 2 Bytes | / | Variable | 1 Byte 1 Byte | |
| Parameter(s) | ||||||
| First Parameter ...... | Last Parameter | |||||
| PID | Size | Options | ...... | PID | Size | Options |
| 2 Bytes | 2 Bytes | Variable | ...... | 2 Bytes | 2 Bytes | Variable |
| See Next Page | ||||||
. Host Requirements
If the device successfully received the above command issued by the host, a "Device ACK" will send to the host right after the device performed the action. Otherwise, a "Device NAK" will be sent to host to issue a command error. However, if the host can not receive any response from the device within the user preset time-out duration, please resend the above command.
. Parameter(s) Field
Set BT Operation can change multiple parameters at one time, so it takes compound parameters.
. Length
Total size (bytes) of the Parameter(s) field
.LRC
"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"
. Size
Total size (bytes) of the Options field
Parameter(s)
< Table 6-4-1 > Set BT Operation Parameter(s) Field (To be continued)
| Parameter / PID / Size Options Descriptions | ||||
| Presentation Auto-sensePID : 00h 02hSize : 00h 01h (1 Byte) | - 00h- 01h | Disable *Enable | ||
| Presentation SensitivityPID : 00h 03hSize : 00h 01h (1 Byte) | - 00h- 01h- 02h- 03h | - 04h- 05h- 06h | Level 1Level 2Level 3Level 4 | Level 5 *Level 6Level 7 |
| Reread DelayPID : 00h 04hSize : 00h 01h (1 Byte) | - 00h- 01h- 02h- 03h- 04h- 05h | DisableImmediate time-out duration *Short time-out durationMedium time-out durationLong time out-durationForce Verification | ||
| Good Read DelayPID : 00h 06hSize : 00h 01h (1 Byte) | - 00h- 01h- 02h- 03h | - 04h- 05h- 06h | None*200 ms500 ms1 s | 1.5 s2 s3 s |
| Light Source On TimePID : 00h 07hSize : 00h 01h (1 Byte) | - 00h- 01h- 02h- 03h | Short (about 2 s) (L & F Series *)Medium (about 3~4 s)Long (about 5~6 s) (A Series *)Extremely Long (about 7~8 s) | ||
| Hands Free Time-outPID : 00h 08hSize : 00h 01h (1 Byte) | - 00h- 06h- 0Ah | - 0Eh- 12h | DisableShort *Medium | LongExtremely long |
| Time Delay To Low Power ModePID : 00h 09hSize : 00h 01h (1 Byte) | - 00h- 01h- 02h | - 03h- 04h- 05h | 1 s3 s5 s | 7 s9 s0 s (Immediately)* |
| Scan Rate ControlPID : 00h 0BhSize : 00h 01h (1 Byte) | - 00h- 01h | Dynamic *Fixed | ||
| Buzzer Tone AdjustPID : 01h 00hSize : 00h 02h (2 Bytes) | 1^st 2^nd Byte- 00h 00h- 01h 01h- 01h 02h- 01h 03h- 01h 04h | MuteLowMedium *HighExtremely High | ||
| Power on beepPID : 01h 01hSize : 00h 01h (1 Byte) | - 00h- 01h | Enable *Disable | ||
Parameter(s)
< Table 6-4-1 > Set BT Operation Parameter(s) Field (Continued)
| Parameter / PID / Size Options Descriptions | ||||
| Power on IndicationPID: 01h 02hSize: 00h 01h (1 Byte) | - 00h- 01h- 02h | LED OffLED On *LED Flash | ||
| VibratorPID: 01h 03hSize: 00h 01h (1 Byte) | - 00h- 01h | DisableEnable * | ||
| Good Read DurationPID: 01h 04hSize: 00h 01h (1 Byte) | - 00h- 01h- 02h | - 03h- 04h | ShortMedium *Long | Extremely longExtremely short |
| Good Read IndicatorPID: 01h 05hSize: 00h 01h (1 Byte) | - 00h- 01h | DisableEnable * | ||
| Beeping ControlPID: 01h 06hSize: 00h 01h (1 Byte) | Bit 0- 0- 1Bit 1- 0- 1 | Radio Connection BeepEnable *DisableBattery Power Low BeepEnable *Disable | ||
| 1D Barcode Inverse ReadingPID: 02h 00hSize: 00h 01h (1 Byte) | - 00h- 01h | Disable *Enable | ||
| Dollar Sign ControlPID: 02h 01hSize: 00h 01h (1 Byte) | - 00h- 80h- A2h | - A3h- A5h | Output as “$” *Output as “€”Output as “¢” | Output as “£”Output as “¥” |
| RedundancyPID: 02h 02hSize: 00h 01h (1 Byte) | - 00h- 01h- 02h | - 03h- 04h- 05h | None1 time *2 times | 3 times4 times5 times |
| Data Transmission Packet (PAIR / PICO Mode)PID: 52h 00hSize: 00h 01h (1 Byte) | - 00h- 01h- 02h- 03h | - 04h- 05h- 06h- 07h | Disable packet *With MACWith IDWith MAC and ID | Enable packetMAC packetID packetMAC and ID packet |
| Data Transmission Packet (HID/ SPP Mode)PID: 52h 00hSize: 00h 01h (1 Byte) | - 00h- 01h | Disable packet *Enable packet | ||
. Warning
If you are using the SmartCradle to communicate with the Scanner, "BT Synchronization" command should be sent to the scanner after the setting of the "Dollar Sign Control" and "Data Transmission Packet" to sync the Scanner with the SmartCradle, so that the settings will take effect immediately.
Parameter(s)
< Table 6-4-1 > Set BT Operation Parameter(s) Field (Continued)
| Parameter / PID / Size Options Descriptions | ||||
| UPC/EAN Security LevelPID: 02h 06hSize: 00h 01h (1 Byte) | - 00h- 01h- 02h | Level 0Level 1 *Level 2 | ||
| Supplement Scan VotingPID: 02h 08hSize: 00h 01h (1 Byte) | - 00h- 06h- 08h- 0Ah- 0Ch- 0Eh- 10h | - 12h- 14h- 16h- 18h- 1Ah- 1Ch- 1Eh | NoneLevel 1Level 2Level 3 *Level 4Level 5Level 6 | Level 7Level 8Level 9Level 10Level 11Level 12Level 13 |
| Operation Mode(Bluetooth F & L Series)PID: 50h 00hSize: 00h 01h (1 Byte) | - 00h- 02h | Trigger mode (External triggering) *Presentation mode (Auto Detection) | ||
| Batch Scanning Link ControlPID: 51h 00hSize: 00h 01h (1 Byte) | - 00h- 01h | Radio DisableRadio Enable * | ||
| Stored Data TransmissionPID: 51h 01hSize: 00h 01h (1 Byte) | - 00h- 01h- 02h | All *On-cradleScan Barcode | ||
| Delete Stored Data AfterTransmissionPID: 51h 02hSize: 00h 01h (1 Byte) | - 00h- 01h | Disable *Enable | ||
| Field DelimiterPID: 51h 03hSize: 00h 01h (1 Byte) | - 00h- 2Ch- 20h | - 2Dh- 2Eh- XXh | None<,> *User-defined 00~7Fh | <-><.-> |
| Batch Data Quantity OutputFormatPID: 51h 04hSize: 00h 01h (1 Byte) | - 00h- 01h- 02h | As many times as the quantity indicates * | ||
. Warning
If you are using the SmartCradle to communicate with the Scanner, "BT Synchronization" command should be sent to the scanner after the setting of the "Field Delimiter" to sync the Scanner with the SmartCradle, so that the settings will take effect immediately.
Parameter(s)
< Table 6-4-1 > Set BT Operation Parameter(s) Field (Continued)
| Parameter / PID / Size Options Descriptions | ||
| Laser Aiming ControlPID : 02h 09hSize : 00h 01h (1 Byte) | - 00h- 01h | DisableEnable * |
| LED IlluminationPID : 02h 0BhSize : 00h 01h (1 Byte) | - 00h- 01h | Always onIntelligent Scanning * |
| Illumination Delay DurationPID : 02h 0ChSize : 00h 01h (1 Byte) | - 00h- 01h- 02h- 03h- 04h | 100ms200ms300ms400ms500ms |
| Operation Mode(Bluetooth A Series)PID : 70h 00hSize : 00h 03h (3 Bytes) | - 00h 01h 01h- 02h 01h 01h | Trigger mode *Presentation mode |
| Hand-Held Mode Illumination& Aiming ControlPID : 70h 01hSize : 00h 01h (1 Byte) | Bit 0- 0- 1Bit 1- 0- 1 | Hand-Held Decode Aiming ControlDisableEnable *Hand-Held Illumination ControlDisableEnable * |
| Hand-Free Mode DecodeAiming ControlPID : 70h 02hSize : 00h 01h (1 Byte) | - 02h- 03h | DisableEnable * |
| Aiming ControlPID : 70h 03hSize : 00h 02h (2 Bytes) | - 00h 00h- 01h 00h- 00h 03h | Regular Aiming *Intelligent AimingDelay Aiming Control |
.Notes
- LED Illumination, Illumination Delay Duration are only available for L680BT, L688BT, L780BT, L788BT.
- Laser Aiming Control is only available for L688BT, L788BT
- Hand-Held Mode Illumination & Aiming Control, Hand-Free Mode Decode Aiming Control and Aiming Control are available for A Series only.
Parameter(s)
< Table 6-1-1 > Set BT Operation Parameter(s) Field (Continued)
| Parameter / PID / Size Options Descriptions | ||
| Delay Aiming TimeoutControlPID : 70h 04hSize : 00h 01h (1 Byte) | - 02h- 04h- 08h- 0Ah- 0Fh- 14h- 1Eh- 28h | 200ms400ms *800ms1000ms1500ms2000ms3000ms4000ms |
| Presentation BackgroundLightingPID : 70h 05hSize : 00h 02h (2 Bytes) | - 00h 00h- 00h FFh | LEDs OffLEDs On * |
| Center AlignmentPID : 70h 06hSize : 00h 02h (2 Bytes) | 1st Byte- 00h- 01h2nd Byte- 00h- 01h | Hand-Held ModeDisable *EnableHand-Free ModeDisable *Enable |
| Mobile Phone CapturePID : 70h 07hSize : 00h 01h (1 Byte) | - 00h- 01h | Disable *Enable |
Notes
Delay Aiming Timeout, Presentation Background Lighting, Center Alignment and Mobile Phone Capture are available for A Series only.
Get BT Operation (BT)
Descriptions
Request the desired one or more parameters of the Operation Settings for Bluetooth Scanner Available for F, L & A series
Packet Format
Prefix Opcode Status Length
7Eh
C9h 00h 00h
00h Variable
If the device successfully received the above command issued by the host, the device will pack all requested parameters into a “Reply BT Operation” message string then send to the host. Please refer to the “Reply BT Operation” command for details. Otherwise, a “Device NAK” will be sent to host to indicate issue a command error. However, if the host can receive any response from the device within the user preset time-out duration, please resend the above command.
. Parameter(s) Field
Get BT Operation can request multiple parameters at one time, so it takes compound parameters.
. Length
Total size (bytes) of the Parameter(s) field
.LRC
"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"
. Size
Total size (bytes) of the Options field
Parameter(s)
< Table 6-4-2 > Get BT Operation Parameter(s) Field
| Parameter PID Size | ||
| Presentation Auto-sense 00h 02h | 00h 00h | |
| Presentation Sensitivity 00h 03h | 00h 00h | |
| Reread Delay 00h 04h | 00h 00h | |
| Good Read Delay 00h 06h | 00h 00h | |
| Light Source On Time 00h 07h | 00h 00h | |
| Hands Free Time-out 00h 08h | 00h 00h | |
| Time Delay To Low Power Mode 00h 09h | 00h 00h | |
| Scan Rate Control 00h 0Bh | 00h 00h | |
| Buzzer Tone Adjust 01h 00h | 00h 00h | |
| Power on beep | 01h 01h | 00h 00h |
| Power on Indication | 01h 02h | 00h 00h |
| Vibrator | 01h 03h | 00h 00h |
| Good Read Duration | 01h 04h | 00h 00h |
| Good Read Indicator | 01h 05h | 00h 00h |
| Beeping Control | 01h 06h | 00h 00h |
| 1D Barcode Inverse Reading | 02h 00h | 00h 00h |
| Dollar Sign Control | 02h 01h | 00h 00h |
| Redundancy | 02h 02h | 00h 00h |
| Data Transmission Packet | 52h 00h | 00h 00h |
| UPC/EAN Security Level | 02h 06h | 00h 00h |
| Supplement Scan Voting 02h 08h | 00h 00h | |
| Operation Mode (Bluetooth F & L Series) | 50h 00h | 00h 00h |
| Batch Scanning Link Control | 51h 00h | 00h 00h |
| Stored Data Transmission | 51h 01h | 00h 00h |
| Delete Stored Data After Transmission | 51h 02h | 00h 00h |
| Field Delimiter | 51h 03h | 00h 00h |
| Batch Data Quantity Output Format | 51h 04h | 00h 00h |
| Laser Aiming Control | 02h 09h | 00h 00h |
| LED Illumination | 02h 0Bh | 00h 00h |
| Illumination Delay Duration | 02h 0Ch | 00h 00h |
| Operation Mode (Bluetooth A Series) | 70h 00h | 00h 00h |
| Hand-Held Mode Illumination & Aiming Control | 70h 01h | 00h 00h |
| Hand-Free Mode Decode Aiming Control | 70h 02h | 00h 00h |
| Aiming Control | 70h 03h | 00h 00h |
| Delay Aiming Timeout | 70h 04h | 00h 00h |
| Presentation Background Lighting | 70h 05h | 00h 00h |
| Center Alignment 70h 06h | 00h 00h | |
| Mobile Phone Capture | 70h 07h | 00h 00h |
Reply BT Operation (BT)
Descriptions
Reply the desired one or more parameters of the Operation Settings for Bluetooth Scanner Reply BT Operation is sent by the device in response to the Get BT Operation command. It sends the values for all the desired parameters requested in the Get BT Operation command. Available for F, L & A series
Packet Format
| Prefix | Opcode | Status | Length | Parameter(s) | LRC | Suffix | ||
| 7Eh | 0Ah | 00h 00h | 00h | Variable | See Below Variable | 7Eh | ||
| 1 Byte | 3 | Bytes | 1 Byte | 2 Bytes | Variable | 1 Byte | 1 Byte | |
| Parameter(s) | ||||||
| First Parameter | ...... | Last Parameter | ||||
| PID | Size | Options | ...... | PID | Size | Options |
| 2 Bytes | 2 Bytes | Variable | ...... | 2 Bytes | 2 Bytes | Variable |
| See Next Page | ||||||
. Host Requirements
Since Reply BT Operation is a device-to-host message, there is no response for this message.
. Parameter(s) Field
Reply BT Operation can change multiple parameters at one time, so it takes compound parameters.
. Length
Total size (bytes) of the Parameter(s) field
.LRC
"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"
. Size
Total size (bytes) of the Options field
Parameter(s)
< Table 6-4-3 > Reply BT Operation Parameter(s) Field (To be continued)
| Parameter / PID / Size Options Descriptions | ||||
| Presentation Auto-sensePID : 00h 02hSize : 00h 01h (1 Byte) | - 00h- 01h | Disable *Enable | ||
| Presentation SensitivityPID : 00h 03hSize : 00h 01h (1 Byte) | - 00h- 01h- 02h- 03h | - 04h- 05h- 06h | Level 1Level 2Level 3Level 4 | Level 5 *Level 6Level 7 |
| Reread DelayPID : 00h 04hSize : 00h 01h (1 Byte) | - 00h- 01h- 02h- 03h- 04h- 05h | DisableImmediate time-out duration *Short time-out durationMedium time-out durationLong time out-durationForce Verification | ||
| Good Read DelayPID : 00h 06hSize : 00h 01h (1 Byte) | - 00h- 01h- 02h- 03h | - 04h- 05h- 06h | None*200 ms500 ms1 s | 1.5 s2 s3 s |
| Light Source On TimePID : 00h 07hSize : 00h 01h (1 Byte) | - 00h- 01h- 02h- 03h | Short (about 2 s) (L & F Series *)Medium (about 3~4 s)Long (about 5~6 s) (A Series *)Extremely Long (about 7~8 s) | ||
| Hands Free Time-outPID : 00h 08hSize : 00h 01h (1 Byte) | - 00h- 06h- 0Ah | - 0Eh- 12h | DisableShort *Medium | LongExtremely long |
| Time Delay To Low Power ModePID : 00h 09hSize : 00h 01h (1 Byte) | - 00h- 01h- 02h | - 03h- 04h- 05h | 1 s3 s5 s | 7 s9 s0 s (Immediately)* |
| Scan Rate ControlPID : 00h 0BhSize : 00h 01h (1 Byte) | - 00h- 01h | Dynamic *Fixed | ||
| Buzzer Tone AdjustPID : 01h 00hSize : 00h 02h (2 Bytes) | 1^st 2^nd Byte- 00h 00h- 01h 01h- 01h 02h- 01h 03h- 01h 04h | MuteLowMedium *HighExtremely High | ||
| Power on beepPID : 01h 01hSize : 00h 01h (1 Byte) | - 00h- 01h | Enable *Disable | ||
Parameter(s)
< Table 6-4-3 > Reply BT Operation Parameter(s) Field (Continued)
| Parameter / PID / Size Options Descriptions | ||||
| Power on IndicationPID: 01h 02hSize: 00h 01h (1 Byte) | - 00h- 01h- 02h | LED OffLED On *LED Flash | ||
| VibratorPID: 01h 03hSize: 00h 01h (1 Byte) | - 00h- 01h | DisableEnable * | ||
| Good Read DurationPID: 01h 04hSize: 00h 01h (1 Byte) | - 00h- 01h- 02h | - 03h- 04h | ShortMedium *Long | Extremely longExtremely short |
| Good Read IndicatorPID: 01h 05hSize: 00h 01h (1 Byte) | - 00h- 01h | DisableEnable * | ||
| Beeping ControlPID: 01h 06hSize: 00h 01h (1 Byte) | Bit 0- 0- 1Bit 1- 0- 1 | Radio Connection BeepEnable *DisableBattery Power Low BeepEnable *Disable | ||
| 1D Barcode Inverse ReadingPID: 02h 00hSize: 00h 01h (1 Byte) | - 00h- 01h | Disable *Enable | ||
| Dollar Sign ControlPID: 02h 01hSize: 00h 01h (1 Byte) | - 00h- 80h- A2h | - A3h- A5h | Output as “$” *Output as “€”Output as “¢” | Output as “£”Output as “¥” |
| RedundancyPID: 02h 02hSize: 00h 01h (1 Byte) | - 00h- 01h- 02h | - 03h- 04h- 05h | None1 time *2 times | 3 times4 times5 times |
| Data Transmission Packet (PAIR / PICO Mode)PID: 52h 00hSize: 00h 01h (1 Byte) | - 00h- 01h- 02h- 03h | - 04h- 05h- 06h- 07h | Disable packet *With MACWith IDWith MAC and ID | Enable packetMAC packetID packetMAC and ID packet |
| Data Transmission Packet (HID/ SPP Mode)PID: 52h 00hSize: 00h 01h (1 Byte) | - 00h- 01h | Disable packet *Enable packet | ||
. Warning
If you are using the SmartCradle to communicate with the Scanner, "BT Synchronization" command should be sent to the scanner after the setting of the "Dollar Sign Control" and "Data Transmission Packet" to sync the Scanner with the SmartCradle, so that the settings will take effect immediately.
Parameter(s)
< Table 6-4-3 > Reply BT Operation Parameter(s) Field (Continued)
| Parameter / PID / Size Options Descriptions | ||||
| UPC/EAN Security LevelPID: 02h 06hSize: 00h 01h (1 Byte) | - 00h- 01h- 02h | Level 0Level 1 *Level 2 | ||
| Supplement Scan VotingPID: 02h 08hSize: 00h 01h (1 Byte) | - 00h- 06h- 08h- 0Ah- 0Ch- 0Eh- 10h | - 12h- 14h- 16h- 18h- 1Ah- 1Ch- 1Eh | NoneLevel 1Level 2Level 3 *Level 4Level 5Level 6 | Level 7Level 8Level 9Level 10Level 11Level 12Level 13 |
| Operation Mode(Bluetooth F & L Series)PID: 50h 00hSize: 00h 01h (1 Byte) | - 00h- 02h | Trigger mode (External triggering) *Presentation mode (Auto Detection) | ||
| Batch Scanning Link ControlPID: 51h 00hSize: 00h 01h (1 Byte) | - 00h- 01h | Radio DisableRadio Enable * | ||
| Stored Data TransmissionPID: 51h 01hSize: 00h 01h (1 Byte) | - 00h- 01h- 02h | All *On-cradleScan Barcode | ||
| Delete Stored Data AfterTransmissionPID: 51h 02hSize: 00h 01h (1 Byte) | - 00h- 01h | Disable *Enable | ||
| Field DelimiterPID: 51h 03hSize: 00h 01h (1 Byte) | - 00h- 2Ch- 20h | - 2Dh- 2Eh- XXh | None<,> *User-defined 00~7Fh | <-><.-> |
| Batch Data Quantity OutputFormatPID: 51h 04hSize: 00h 01h (1 Byte) | - 00h- 01h- 02h | As many times as the quantity indicates * | ||
. Warning
If you are using the SmartCradle to communicate with the Scanner, "BT Synchronization" command should be sent to the scanner after the setting of the "Field Delimiter" to sync the Scanner with the SmartCradle, so that the settings will take effect immediately.
Parameter(s)
< Table 6-4-3 > Reply BT Operation Parameter(s) Field (Continued)
| Parameter / PID / Size Options Descriptions | ||
| Laser Aiming ControlPID : 02h 09hSize : 00h 01h (1 Byte) | - 00h- 01h | DisableEnable * |
| LED IlluminationPID : 02h 0BhSize : 00h 01h (1 Byte) | - 00h- 01h | Always onIntelligent Scanning * |
| Illumination Delay DurationPID : 02h 0ChSize : 00h 01h (1 Byte) | - 00h- 01h- 02h- 03h- 04h | 100ms200ms300ms400ms500ms |
| Operation Mode(Bluetooth A Series)PID : 70h 00hSize : 00h 03h (3 Bytes) | - 00h 01h 01h- 02h 01h 01h | Trigger mode *Presentation mode |
| Hand-Held Mode Illumination& Aiming ControlPID : 70h 01hSize : 00h 01h (1 Byte) | Bit 0- 0- 1Bit 1- 0- 1 | Hand-Held Decode Aiming ControlDisableEnable *Hand-Held Illumination ControlDisableEnable * |
| Hand-Free Mode DecodeAiming ControlPID : 70h 02hSize : 00h 01h (1 Byte) | - 02h- 03h | DisableEnable * |
| Aiming ControlPID : 70h 03hSize : 00h 02h (2 Bytes) | - 00h 00h- 01h 00h- 00h 03h | Regular Aiming *Intelligent AimingDelay Aiming Control |
.Notes
- LED Illumination, Illumination Delay Duration are only available for L680BT, L688BT, L780BT, L788BT.
- Laser Aiming Control is only available for L688BT, L788BT
- Hand-Held Mode Illumination & Aiming Control, Hand-Free Mode Decode Aiming Control and Aiming Control are available for A Series only.
Parameter(s)
< Table 6-1-1 > Set BT Operation Parameter(s) Field (Continued)
| Parameter / PID / Size Options Descriptions | ||
| Delay Aiming TimeoutControlPID : 70h 04hSize : 00h 01h (1 Byte) | - 02h- 04h- 08h- 0Ah- 0Fh- 14h- 1Eh- 28h | 200ms400ms *800ms1000ms1500ms2000ms3000ms4000ms |
| Presentation BackgroundLightingPID : 70h 05hSize : 00h 02h (2 Bytes) | - 00h 00h- 00h FFh | LEDs OffLEDs On * |
| Center AlignmentPID : 70h 06hSize : 00h 02h (2 Bytes) | 1st Byte- 00h- 01h2nd Byte- 00h- 01h | Hand-Held ModeDisable *EnableHand-Free ModeDisable *Enable |
| Mobile Phone CapturePID : 70h 07hSize : 00h 01h (1 Byte) | - 00h- 01h | Disable *Enable |
Notes
Delay Aiming Timeout, Presentation Background Lighting, Center Alignment and Mobile Phone Capture are available for A Series only.
Set WF Operation (WF)
Descriptions
Change the desired one or more parameters of the Operation Settings for Wi-Fi Scanner.
Available for F & L series
Packet Format
| Prefix | Opcode | Status | Length | Parameter(s) | LRC | Suffix | ||
| 7Eh | 88h | 00h | 00h | Variable | See Below Variable | 7Eh | ||
| 1 Byte | 3 | Bytes | 1 Byte | 2 Bytes | / | Variable | 1 Byte 1 Byte | |
| Parameter(s) | ||||||
| First Parameter ...... | Last Parameter | |||||
| PID | Size | Options | ...... | PID | Size | Options |
| 2 Bytes | 2 Bytes | Variable | ...... | 2 Bytes | 2 Bytes | Variable |
| See Next Page | ||||||
. Host Requirements
If the device successfully received the above command issued by the host, a "Device ACK" will send to the host right after the device performed the action. Otherwise, a "Device NAK" will be sent to host to issue a command error. However, if the host can not receive any response from the device within the user preset time-out duration, please resend the above command.
. Parameter(s) Field
Set SE Operation can change multiple parameters at one time, so it takes compound parameters.
. Length
Total size (bytes) of the Parameter(s) field
.LRC
"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"
. Size
Total size (bytes) of the Options field
Parameter(s)
< Table 6-5-1 > Set WF Operation Parameter(s) Field (To be continued)
| Parameter / PID / Size Options Descriptions | ||||
| Power Saving TimeoutPID: 00h 09hSize: 00h 01h (1 Byte) | - 00h- 01h- 02h | - 03h- 04h- 05h | 1 second5 seconds *10 seconds | 20 seconds30 secondsImmediately |
| Buzzer Tone AdjustPID: 01h 00hSize: 00h 02h (2 Bytes) | 1^st 2^nd Byte- 00h 00h- 01h 01h- 01h 02h- 01h 03h- 01h 04h | MuteLowMedium *HighExtremely High | ||
| Power on beepPID: 01h 01hSize: 00h 01h (1 Byte) | - 00h- 01h | Enable *Disable | ||
| Power on IndicationPID: 01h 02hSize: 00h 01h (1 Byte) | - 00h- 01h- 02h | Disable (LED off)LED steady on *LED flash | ||
| VibratorPID: 01h 03hSize: 00h 01h (1 Byte) | - 00h- 01h | Disable *Enable | ||
| 1D Barcode Inverse ReadingPID: 02h 00hSize: 00h 01h (1 Byte) | - 00h- 01h | Disable *Enable | ||
| Dollar Sign ControlPID: 02h 01hSize: 00h 01h (1 Byte) | - 00h- 80h- A2h | - A3h- A5h | Output as “$” *Output as “€”Output as “¢” | Output as “£”Output as “¥” |
| RedundancyPID: 02h 02hSize: 00h 01h (1 Byte) | - 00h- 01h- 02h | - 03h- 04h- 05h | NoneLevel 1 *Level 2 | Level 3Level 4Level 5 |
| Good Read DelayPID: 00h 06hSize: 00h 01h (1 Byte) | - 00h- 01h- 02h- 03h | - 04h- 05h- 06h | None*200 ms500 ms1 s | 1.5 s2 s3 s |
| Good Read DurationPID: 01h 04hSize: 00h 01h (1 Byte) | - 00h- 01h- 02h | - 03h- 04h | ShortMedium *Long | Extremely longExtremely short |
| Good Read IndicatorPID: 01h 05hSize: 00h 01h (1 Byte) | - 00h- 01h | DisableEnable * | ||
Parameter(s)
< Table 6-5-1 > Set WF Operation Parameter(s) Field (Continued)
| Parameter / PID / Size Options Descriptions | ||
| Beeping ControlPID : 01h 06hSize : 00h 01h (1 Byte) | Bit 0- 0- 1Bit 1- 0- 1 | Radio Connection BeepEnable *DisableBattery Power Low BeepEnable *Disable |
| Scan Rate ControlPID : 00h 0BhSize : 00h 01h (1 Byte) | - 00h- 01h | Dynamic *Fixed |
| Laser Aiming ControlPID : 02h 09hSize : 00h 01h (1 Byte) | - 00h- 01h | DisableEnable * |
| LED IlluminationPID : 02h 0BhSize : 00h 01h (1 Byte) | - 00h- 01h | Always onIntelligent Scanning * |
| Illumination Delay DurationPID : 02h 0ChSize : 00h 01h (1 Byte) | - 00h- 01h- 02h- 03h- 04h | 100ms200ms300ms400ms500ms |
. Note
- Laser Aiming Control is only available for L788WD
- LED Illumination, Illumination Delay Duration are only available for L780WD, L788WD
Get WF Operation (WF)
Descriptions
Request the desired one or more parameters of the Operation Settings for Wi-Fi Scanner Available for F & L series
Packet Format
| Prefix | Opcode | Status | Length | Parameter(s) | LRC | Suffix | |||
| 7Eh | C9h | 00h | 00h | Variable | See Below | Variable | 7Eh | ||
| 1 Byte | 3 | Bytes | 1 Byte | 2 Bytes | Variable | 1 Byte | 1 Byte | ||
| Parameter(s) | |||||||||
| First Parameter | ...... | Last Parameter | |||||||
| PID Size ...... | PID Size | ||||||||
| 2 Bytes | 2 Bytes | ...... | 2 Bytes | 2 Bytes | |||||
| See Next Page | |||||||||
. Host Requirements
If the device successfully received the above command issued by the host, the device will pack all requested parameters into a "Reply SE Operation" message string then send to the host. Please refer to the "Reply SE Operation" command for details. Otherwise, a "Device NAK" will be sent to host to indicate issue a command error. However, if the host can receive any response from the device within the user preset time-out duration, please resend the above command.
. Parameter(s) Field
Get SE Operation can request multiple parameters at one time, so it takes compound parameters.
. Length
Total size (bytes) of the Parameter(s) field
.LRC
"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"
. Size
Total size (bytes) of the Options field
Parameter(s)
< Table 6-5-2 > Get WF Operation Parameter(s) Field
| Parameter PID Size | ||
| Power Saving Timeout 00h 09h | 00h 00h | |
| Buzzer Tone Adjust 01h 00h | 00h 00h | |
| Power on beep 01h 01h | 00h 00h | |
| Power on Indication 01h 02h | 00h 00h | |
| Vibrator 01h 03h | 00h 00h | |
| 1D Barcode Inverse Reading 02h 00h | 00h 00h | |
| Dollar Sign Control 02h 01h | 00h 00h | |
| Redundancy 02h 02h | 00h 00h | |
| Good Read Delay 00h 06h | 00h 00h | |
| Good Read Duration | 01h 04h | 00h 00h |
| Good Read Indicator | 01h 05h | 00h 00h |
| Beeping Control | 01h 06h | 00h 00h |
| Scan Rate Control | 00h 0Bh | 00h 00h |
| Laser Aiming Control | 02h 09h | 00h 00h |
| LED Illumination | 02h 0Bh | 00h 00h |
| Illumination Delay Duration | 02h 0Ch | 00h 00h |
Reply WF Operation (WF)
Descriptions
Reply the desired one or more parameters of the Operation Settings for Wi-Fi Scanner Reply WF Operation is sent by the device in response to the Get WF Operation command. It sends the values for all the desired parameters requested in the Get WF Operation command. Available for F & L series
Packet Format
| Prefix | Opcode | Status | Length | Parameter(s) | LRC | Suffix | |||
| 7Eh | 0Ah | 00h | 00h | Variable | See Below | Variable | 7Eh | ||
| 1 Byte | 3 | Bytes | 1 Byte | 2 Bytes | Variable | 1 Byte | 1 Byte | ||
| Parameter(s) | |||||||||
| First Parameter | ...... | Last Parameter | |||||||
| PID | Size | Options | ...... | PID | Size | Options | |||
| 2 Bytes | 2 Bytes | Variable | ...... | 2 Bytes | 2 Bytes | Variable | |||
| See Next Page | |||||||||
| Parameter(s) | ||||||
| First Parameter | ...... | Last Parameter | ||||
| PID | Size | Options | ...... | PID | Size | Options |
| 2 Bytes | 2 Bytes | Variable | ...... | 2 Bytes | 2 Bytes | Variable |
| See Next Page | ||||||
. Host Requirements
Since Reply SE Operation is a device-to-host message, there is no response for this message.
. Parameter(s) Field
Set SE Operation can change multiple parameters at one time, so it takes compound parameters.
. Length
Total size (bytes) of the Parameter(s) field
.LRC
"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"
. Size
Total size (bytes) of the Options field
Parameter(s)
< Table 6-5-3 > Reply WF Operation Parameter(s) Field (To be continued)
| Parameter / PID / Size Options Descriptions | ||||
| Power Saving TimeoutPID : 00h 09hSize : 00h 01h (1 Byte) | - 00h- 01h- 02h | - 03h- 04h- 05h | 1 second5 seconds *10 seconds | 20 seconds30 secondsImmediately |
| Buzzer Tone AdjustPID : 01h 00hSize : 00h 02h (2 Bytes) | 1^st 2^nd Byte- 00h 00h- 01h 01h- 01h 02h- 01h 03h- 01h 04h | MuteLowMedium *HighExtremely High | ||
| Power on beepPID : 01h 01hSize : 00h 01h (1 Byte) | - 00h- 01h | Enable *Disable | ||
| Power on IndicationPID : 01h 02hSize : 00h 01h (1 Byte) | - 00h- 01h- 02h | Disable (LED off)LED steady on *LED flash | ||
| VibratorPID : 01h 03hSize : 00h 01h (1 Byte) | - 00h- 01h | Disable *Enable | ||
| 1D Barcode Inverse ReadingPID : 02h 00hSize : 00h 01h (1 Byte) | - 00h- 01h | Disable *Enable | ||
| Dollar Sign ControlPID : 02h 01hSize : 00h 01h (1 Byte) | - 00h- 80h- A2h | - A3h- A5h | Output as “$” *Output as “€”Output as “¢” | Output as “£”Output as “¥” |
| RedundancyPID : 02h 02hSize : 00h 01h (1 Byte) | - 00h- 01h- 02h | - 03h- 04h- 05h | NoneLevel 1 *Level 2 | Level 3Level 4Level 5 |
| Good Read DelayPID : 00h 06hSize : 00h 01h (1 Byte) | - 00h- 01h- 02h- 03h | - 04h- 05h- 06h | None*200 ms500 ms1 s | 1.5 s2 s3 s |
| Good Read DurationPID : 01h 04hSize : 00h 01h (1 Byte) | - 00h- 01h- 02h | - 03h- 04h | ShortMedium *Long | Extremely longExtremely short |
| Good Read IndicatorPID : 01h 05hSize : 00h 01h (1 Byte) | - 00h- 01h | DisableEnable * | ||
Parameter(s)
< Table 6-5-3 > Reply WF Operation Parameter(s) Field (Continued)
| Parameter / PID / Size Options Descriptions | ||
| Beeping ControlPID : 01h 06hSize : 00h 01h (1 Byte) | Bit 0- 0- 1Bit 1- 0- 1 | Radio Connection BeepEnable *DisableBattery Power Low BeepEnable *Disable |
| Scan Rate ControlPID : 00h 0BhSize : 00h 01h (1 Byte) | - 00h- 01h | Dynamic *Fixed |
| Laser Aiming ControlPID : 02h 09hSize : 00h 01h (1 Byte) | - 00h- 01h | Disable *Enable |
| LED IlluminationPID : 02h 0BhSize : 00h 01h (1 Byte) | - 00h- 01h | Always on Intelligent Scanning * |
| Illumination Delay DurationPID : 02h 0ChSize : 00h 01h (1 Byte) | - 00h- 01h- 02h- 03h- 04h | 100ms200ms300ms400ms500ms |
. Note
- Laser Aiming Control is only available for L788WD
- LED Illumination, Illumination Delay Duration are only available for L780WD, L788WD
Command Descriptions
Set WF System (WF)
Descriptions
Change the desired one or more parameters of the System Settings for Wi-Fi Scanner.
Available for F & L series
Packet Format
| Prefix | Opcode | Status | Length | Parameter(s) | LRC | Suffix | ||
| 7Eh | A1h 00h 00h | 00h Variable | See Below Variable | 7Eh | ||||
| 1 Byte | 3 | Bytes | 1 Byte | 2 Bytes | Variable | 1 Byte | 1 Byte | |
| Parameter(s) | ||||||
| First Parameter ...... | Last Parameter | |||||
| PID | Size | Options | ...... | PID | Size | Options |
| 2 Bytes | 2 Bytes | Variable | ...... | 2 Bytes | 2 Bytes | Variable |
| See Next Page | ||||||
. Host Requirements
If the device successfully received the above command issued by the host, a "Device ACK" will send to the host right after the device performed the action. Otherwise, a "Device NAK" will be sent to host to issue a command error. However, if the host can not receive any response from the device within the user preset time-out duration, please resend the above command.
. Parameter(s) Field
Set SE Operation can change multiple parameters at one time, so it takes compound parameters.
. Length
Total size (bytes) of the Parameter(s) field
.LRC
"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"
. Size
Total size (bytes) of the Options field
Parameter(s)
< Table 6-6-1 > Set WF System Parameter(s) Field (To be continued)
| Parameter / PID / Size Options Descriptions | ||||
| Wi-Fi Device NamePID : 00h 00hSize : 00h 11h (17 Bytes) | 1^st Byte- XXh 2^nd 17^th Byte- XXh XXh...XXh | Total number of the Device Name in charactersUser defined 1~16 character(s) (See Note) | ||
| Admin PasswordPID : 00h 01hSize : 00h 04h (4 Bytes) | - 00h 00h 00h00h- XXh XXh...XXh | Default *User defined 4 digits (See Note) | ||
| User PasswordPID : 00h 02hSize : 00h 04h (4 Bytes) | - 00h 00h 00h00h-XXh XXh...XXh | Default *User defined 4 digits (See Note) | ||
| User Available FunctionsPID : 00h 03hSize : 00h 01h (3 Bytes) | 1^st Byte- 00h- 01h 2^nd Byte- 00h- 01h 3^rd Byte- 00h- 01h | Online ModeDisableEnable *Batch ModeDisableEnable *ToolsDisableEnable * | ||
| BrightnessPID : 00h 04hSize : 00h 01h (1 Byte) | - 00h- 01h | High *Low | ||
| Backlight DurationPID : 00h 05hSize : 00h 01h (1 Byte) | - 05h- 0Ah- 0Fh- 14h | - 19h- 1Eh- 2Dh- 3Ch | 5 seconds10 seconds15 seconds20 seconds | 25 seconds30 seconds *45 seconds60 seconds |
| Key TonesPID : 00h 06hSize : 00h 01h (1 Byte) | - 00h- 01h- 02h- 03h- 04h | Extremely High *HighMediumLowMute | ||
| Wake Up KeyPID : 00h 07hSize : 00h 01h (1 Byte) | - 00h- 01h | Trigger *Trigger + R | ||
.Notes
- Device Name: If the desired ASCII characters are shorter than 16 bytes, the rest bytes should be set to 00h. To set to default device name, this parameter should be set to: 00h FFh...FFh (sixteen "FFh"s)
- Admin Password/ User Password should be set to four 0\~9 digit numbers, because the password Keyboard is preset to Numeric Keyboard, and you can only enter digit number.
Command Descriptions
Get WF System (WF)
Descriptions
Request the desired one or more parameters of the System Settings for Wi-Fi Scanner Available for F & L series
Packet Format
| Prefix | Opcode | Status | Length | Parameter(s) | LRC | Suffix | |||
| 7Eh | E2h | 00h | 00h | Variable | See Below | Variable | 7Eh | ||
| 1 Byte | 3 | Bytes | 1 Byte | 2 Bytes | Variable | 1 Byte | 1 Byte | ||
| Parameter(s) | |||||||||
| First Parameter | ...... | Last Parameter | |||||||
| PID Size | PID Size | ||||||||
| 2 Bytes | 2 Bytes | ...... | 2 Bytes | 2 Bytes | |||||
| See Next Page | |||||||||
. Host Requirements
If the device successfully received the above command issued by the host, the device will pack all requested parameters into a "Reply WF System" message string then send to the host. Please refer to the "Reply WF System" command for details. Otherwise, a "Device NAK" will be sent to host to indicate issue a command error. However, if the host can receive any response from the device within the user preset time-out duration, please resend the above command.
. Parameter(s) Field
Get SE Operation can request multiple parameters at one time, so it takes compound parameters.
. Length
Total size (bytes) of the Parameter(s) field
.LRC
"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"
. Size
Total size (bytes) of the Options field
Parameter(s)
< Table 6-6-2 > Get WF System Parameter(s) Field
| Parameter PID Size | ||
| Wi-Fi Device Name 00h 00h | 00h 00h | |
| Admin Password 00h 01h | 00h 00h | |
| User Password 00h 02h | 00h 00h | |
| User Available Functions 00h 03h | 00h 00h | |
| Brightness 00h 04h | 00h 00h | |
| Backlight Duration 00h 05h | 00h 00h | |
| Key Tones 00h 06h | 00h 00h | |
| Wake Up Key 00h 07h | 00h 00h |
Reply WF System (WF)
Descriptions
Reply the desired one or more parameters of the System Settings for Wi-Fi Scanner Reply WF System is sent by the device in response to the Get WF System command. It sends the values for all the desired parameters requested in the Get WF System command. Available for F & L series
Packet Format
| Prefix | Opcode | Status | Length | Parameter(s) | LRC | Suffix | |||
| 7Eh | 23h | 00h | 00h | Variable | See Below | Variable | 7Eh | ||
| 1 Byte | 3 | Bytes | 1 Byte | 2 Bytes | Variable | 1 Byte | 1 Byte | ||
| Parameter(s) | |||||||||
| First Parameter | ...... | Last Parameter | |||||||
| PID | Size | Options | ...... | PID | Size | Options | |||
| 2 Bytes | 2 Bytes | Variable | ...... | 2 Bytes | 2 Bytes | Variable | |||
| See Next Page | |||||||||
. Host Requirements
Since Reply SE Operation is a device-to-host message, there is no response for this message.
. Parameter(s) Field
Set SE Operation can change multiple parameters at one time, so it takes compound parameters.
. Length
Total size (bytes) of the Parameter(s) field
.LRC
"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"
. Size
Total size (bytes) of the Options field
Parameter(s)
< Table 6-6-3 > Reply WF System Parameter(s) Field (To be continued)
| Parameter / PID / Size Options Descriptions | ||||
| Wi-Fi Device NamePID : 00h 00hSize : 00h 11h (17 Bytes) | 1^st Byte- XXh 2^nd 17^th Byte- XXh XXh...XXh | Total number of the Device Name in charactersUser defined 1~16 character(s) (See Note) | ||
| Admin PasswordPID : 00h 01hSize : 00h 04h (4 Bytes) | - 00h 00h 00h00h- XXh XXh...XXh | Default *User defined 4 digits | ||
| User PasswordPID : 00h 02hSize : 00h 04h (4 Bytes) | - 00h 00h 00h00h-XXh XXh...XXh | Default *User defined 4 digits | ||
| User Available FunctionsPID : 00h 03hSize : 00h 01h (3 Bytes) | 1^st Byte- 00h- 01h 2^nd Byte- 00h- 01h 3^rd Byte- 00h- 01h | Online ModeDisableEnable *Batch ModeDisableEnable *ToolsDisableEnable * | ||
| BrightnessPID : 00h 04hSize : 00h 01h (1 Byte) | - 00h- 01h | High *Low | ||
| Backlight DurationPID : 00h 05hSize : 00h 01h (1 Byte) | - 05h- 0Ah- 0Fh- 14h | - 19h- 1Eh- 2Dh- 3Ch | 5 seconds10 seconds15 seconds20 seconds | 25 seconds30 seconds *45 seconds60 seconds |
| Key TonesPID : 00h 06hSize : 00h 01h (1 Byte) | - 00h- 01h- 02h- 03h- 04h | Extremely High *HighMediumLowMute | ||
| Wake Up KeyPID : 00h 07hSize : 00h 01h (1 Byte) | - 00h- 01h | Trigger *Trigger + R | ||
Set WF Scanning (WF)
Descriptions
Change the desired one or more parameters of the Scanning Settings for Wi-Fi Scanner.
Available for F & L series
Packet Format
| Prefix | Opcode | Status | Length | Parameter(s) | LRC | Suffix | ||
| 7Eh | 9Eh | 00h | 00h | Variable | See Below Variable | 7Eh | ||
| 1 Byte | 3 | Bytes | 1 Byte | 2 Bytes | / | Variable | 1 Byte | |
| Parameter(s) | ||||||
| First Parameter ...... | Last Parameter | |||||
| PID | Size | Options | ...... | PID | Size | Options |
| 2 Bytes | 2 Bytes | Variable | ...... | 2 Bytes | 2 Bytes | Variable |
| See Next Page | ||||||
. Host Requirements
If the device successfully received the above command issued by the host, a "Device ACK" will send to the host right after the device performed the action. Otherwise, a "Device NAK" will be sent to host to issue a command error. However, if the host can not receive any response from the device within the user preset time-out duration, please resend the above command.
. Parameter(s) Field
Set SE Operation can change multiple parameters at one time, so it takes compound parameters.
. Length
Total size (bytes) of the Parameter(s) field
.LRC
"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"
. Size
Total size (bytes) of the Options field
Parameter(s)
< Table 6-7-1 > Set WF Scanning Parameter(s) Field (To be continued)
| Parameter / PID / Size Options Descriptions | ||||
| Barcode TypePID : 00h 00hSize : 00h 01h (1 Byte) | - 00h- 01h | DisableEnable * | ||
| Font SizePID : 00h 01hSize : 00h 01h (1 Byte) | - 00h- 01h | Compact *Normal | ||
| Record SuffixPID : 00h 02hSize : 00h 02h (2 Bytes) | 1^st 2^nd Byte- FFh FFh- 0Dh FFh- 0Ah FFh- 0Dh 0Ah- 09h FFh- 20h FFh- 04h FFh- XXh FFh | NoneCR *LF *CRLFTABSPACEEOTUser defined ASCII value | ||
| Host ACKPID : 00h 03hSize : 00h 01h (1 Byte) | - 00h- 01h | DisableEnable * | ||
| Transmission FormatPID : 00h 04hSize : 00h 01h (1 Byte) | - 00h- 01h | Raw Data *Packet Data | ||
| Host ACK TimeoutPID : 00h 05hSize : 00h 01h (1 Byte) | - 01h- 04h- 09h- 0Fh- 12h- 24h | - 4Fh- 50h- 48h- 56h- 5Ah- 61h | None200 mseconds500 mseconds800 mseconds1 second *2 seconds | 3 seconds4 seconds5 seconds8 seconds10 seconds15 seconds |
| ACK IndicationPID : 00h 07hSize : 00h 01h (1 Byte) | Bit 0- 0h- 1hBit 1- 0h- 1h | Transmission Timeout IndicationDisableEnable *ACK IndicationDisableEnable * | ||
| Field DelimiterPID : 00h 09hSize : 00h 01h (1 Byte) | - 2Ch- XXh | ,*User defined ASCII value | ||
| Record DelimiterPID : 00h 0AhSize : 00h 01h (1 Byte) | - 0Dh- XXh | [CR] *User defined ASCII value | ||
| Timestamp FormatPID : 00h 0BhSize : 00h 01h (1 Byte) | - 00h- 01h- 02h- 03h- 04h- 05h | hh:mm dd/mm/yyyy *hh:mm mm/dd/yyyyhh:mm yyyy/mm/dddd/mm/yyyy hh:mmmm/dd/yyyy hh:mmyyyy/mm/dd hh:mm | ||
Parameter(s)
< Table 6-7-1 > Set WF Scanning Parameter(s) Field (Continued)
| Parameter / PID / Size Options Descriptions | ||
| Auto Save | ||
| PID : 00h 0Ch | - 00h | Disable |
| Size : 00h 01h (1 Byte) | - 01h | Enable with tip |
| - 02h | Enable without tip * | |
| Link Control | ||
| PID : 00h 0Dh | - 00h | Radio Disable |
| Size : 00h 01h (1 Byte) | - 01h | Radio Enable * |
| Delete Stored Data | ||
| PID : 00h 0Eh | - 00h | Disable * |
| Size : 00h 01h (1 Byte) | - 01h | Enable |
| Data Transmission | ||
| PID : 00h 0Fh | - 00h | Via Wi-Fi * |
| Size : 00h 01h (1 Byte) | - 01h | Via USB HID |
| - 02h | Via USB COM | |
Get WF Scanning (WF)
Descriptions
Request the desired one or more parameters of the Scanning Settings for Wi-Fi Scanner Available for F & L series
Packet Format
| Prefix | Opcode | Status | Length | Parameter(s) | LRC | Suffix | |||
| 7Eh | DFh | 00h 00h | 00h | Variable | See Below | Variable | 7Eh | ||
| 1 Byte | 3 | Bytes | 1 Byte | 2 Bytes | Variable | 1 Byte | 1 Byte | ||
| Parameter(s) | |||||||||
| First Parameter | ...... | Last Parameter | |||||||
| PID Size ...... | PID Size | ||||||||
| 2 Bytes | 2 Bytes | ...... | 2 Bytes | 2 Bytes | |||||
| See Next Page | |||||||||
. Host Requirements
If the device successfully received the above command issued by the host, the device will pack all requested parameters into a "Reply WF Scanning" message string then send to the host. Please refer to the "Reply WF Scanning" command for details. Otherwise, a "Device NAK" will be sent to host to indicate issue a command error. However, if the host can receive any response from the device within the user preset time-out duration, please resend the above command.
. Parameter(s) Field
Get SE Operation can request multiple parameters at one time, so it takes compound parameters.
. Length
Total size (bytes) of the Parameter(s) field
.LRC
"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"
. Size
Total size (bytes) of the Options field
Parameter(s)
< Table 6-7-2 > Get WF Scanning Parameter(s) Field
| Parameter PID Size | ||
| Barcode Type 00h 00h | 00h 00h | |
| Font Size 00h 01h | 00h 00h | |
| Record Suffix 00h 02h | 00h 00h | |
| Host ACK 00h 03h | 00h 00h | |
| Transmission Format 00h 04h | 00h 00h | |
| Host ACK Timeout 00h 05h | 00h 00h | |
| ACK Indication 00h 07h | 00h 00h | |
| Field Delimiter 00h 09h | 00h 00h | |
| Record Delimiter 00h 0Ah | 00h 00h | |
| Timestamp Format 00h 0Bh | 00h 00h | |
| Auto Save | 00h 0Ch | 00h 00h |
| Link Control | 00h 0Dh | 00h 00h |
| Delete Stored Data | 00h 0Eh | 00h 00h |
| Data Transmission | 00h 0Fh | 00h 00h |
Reply WF Scanning (WF)
Descriptions
Reply the desired one or more parameters of the Scanning Settings for Wi-Fi Scanner Reply WF Scanning is sent by the device in response to the Get WF Scanning command. It sends the values for all the desired parameters requested in the Get WF Scanning command. Available for F & L series
Packet Format
| Prefix | Opcode | Status | Length | Parameter(s) | LRC | Suffix | |||
| 7Eh | 20h | 00h | 00h | Variable | See Below | Variable | 7Eh | ||
| 1 Byte | 3 | Bytes | 1 Byte | 2 Bytes | Variable | 1 Byte | 1 Byte | ||
| Parameter(s) | ||||||
| First Parameter | ...... | Last Parameter | ||||
| PID | Size | Options | ...... | PID | Size | Options |
| 2 Bytes | 2 Bytes | Variable | ...... | 2 Bytes | 2 Bytes | Variable |
| See Next Page | ||||||
. Host Requirements
Since Reply SE Operation is a device-to-host message, there is no response for this message.
. Parameter(s) Field
Set SE Operation can change multiple parameters at one time, so it takes compound parameters.
. Length
Total size (bytes) of the Parameter(s) field
.LRC
"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"
. Size
Total size (bytes) of the Options field
Parameter(s)
< Table 6-7-3 > Reply WF Scanning Parameter(s) Field (To be continued)
| Parameter / PID / Size Options Descriptions | ||||
| Barcode TypePID : 00h 00hSize : 00h 01h (1 Byte) | - 00h- 01h | DisableEnable * | ||
| Font SizePID : 00h 01hSize : 00h 01h (1 Byte) | - 00h- 01h | Compact *Normal | ||
| Record SuffixPID : 00h 02hSize : 00h 02h (2 Bytes) | 1^st 2^nd Byte- FFh FFh- 0Dh FFh- 0Ah FFh- 0Dh 0Ah- 09h FFh- 20h FFh- 04h FFh- XXh FFh | NoneCR *LF *CRLFTABSPACEEOTUser defined ASCII value | ||
| Host ACKPID : 00h 03hSize : 00h 01h (1 Byte) | - 00h- 01h | DisableEnable * | ||
| Transmission FormatPID : 00h 04hSize : 00h 01h (1 Byte) | - 00h- 01h | Raw Data *Packet Data | ||
| Host ACK TimeoutPID : 00h 05hSize : 00h 01h (1 Byte) | - 01h- 04h- 09h- 0Fh- 12h- 24h | - 4Fh- 50h- 48h- 56h- 5Ah- 61h | None200 mseconds500 mseconds800 mseconds1 second *2 seconds | 3 seconds4 seconds5 seconds8 seconds10 seconds15 seconds |
| ACK IndicationPID : 00h 07hSize : 00h 01h (1 Byte) | Bit 0- 0h- 1hBit 1- 0h- 1h | Transmission Timeout IndicationDisableEnable *ACK IndicationDisableEnable * | ||
| Field DelimiterPID : 00h 09hSize : 00h 01h (1 Byte) | - 2Ch- XXh | ,*User defined ASCII value | ||
| Record DelimiterPID : 00h 0AhSize : 00h 01h (1 Byte) | - 0Dh- XXh | [CR] *User defined ASCII value | ||
| Timestamp FormatPID : 00h 0BhSize : 00h 01h (1 Byte) | - 00h- 01h- 02h- 03h- 04h- 05h | hh:mm dd/mm/yyyy *hh:mm mm/dd/yyyyhh:mm yyyy/mm/dddd/mm/yyyy hh:mmmm/dd/yyyy hh:mmyyyy/mm/dd hh:mm | ||
Parameter(s)
< Table 6-7-3 > Reply WF Scanning Parameter(s) Field (Continued)
| Parameter / PID / Size Options Descriptions | ||
| Auto Save | ||
| PID : 00h 0Ch | - 00h | Disable |
| Size : 00h 01h (1 Byte) | - 01h | Enable with tip |
| - 02h | Enable without tip * | |
| Link Control | ||
| PID : 00h 0Dh | - 00h | Radio Disable |
| Size : 00h 01h (1 Byte) | - 01h | Radio Enable * |
| Delete Stored Data | ||
| PID : 00h 0Eh | - 00h | Disable * |
| Size : 00h 01h (1 Byte) | - 01h | Enable |
| Data Transmission | ||
| PID : 00h 0Fh | - 00h | Via Wi-Fi * |
| Size : 00h 01h (1 Byte) | - 01h | Via USB HID |
| - 02h | Via USB COM | |
2.7 Transmission
Set Transmission (ALL)
Descriptions
Change the desired one or more parameters of the Transmission settings as well as DataWizard Premium parameters including Data Script Active Setting, Data Script Setting, Security Script Setting and Data Wizard Premium Error Message.
DataWizard Premium parameters are only available for Scanners that support DataWizard Premium. For more details about DataWizard Premium, please refer to FuzzyScan DataWizard Premium User Manual.
Packet Format
| Prefix | Opcode | Status | Length | Parameter(s) | LRC | Suffix | ||
| 7Eh | 8Bh | 00h 00h | 00h Variable | See Below Variable | 7Eh | |||
| 1 Byte | 3 | Bytes | 1 Byte | 2 Bytes | Variable | 1 Byte | ||
| Parameter(s) | ||||||
| First Parameter | ...... | Last Parameter | ||||
| PID | Size | Options | ...... | PID | Size O | Options |
| 2 Bytes | 2 Bytes | Variable | ...... | 2 Bytes | 2 Bytes | Variable |
| See Next Page | ||||||
. Host Requirements
If the device successfully received the above command issued by the host, a "Device ACK" will send to the host right after the device performed the action. Otherwise, a "Device NAK" will be sent to host to issue a command error. However, if the host can not receive any response from the device within the user preset time-out duration, please resend the above command.
. Parameter(s) Field
Set Transmission can change multiple parameters at one time, so it takes compound parameters.
. Length
Total size (bytes) of the Parameter(s) field
.LRC
"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"
. Size
Total size (bytes) of the Options field
Parameter(s)
< Table 7-1-1 > Set Transmission Parameter(s) Field (To be continued)
| Parameter / PID / Size Options Descriptions | ||
| Interface Delay SettingsPID : 00h 00hSize : 00h 03h (3 Bytes) | 1^st Byte- 00h- 01h~63h 2^nd Byte- 00h- 01h~63h 3^rd Byte- 00h- 01h~63h | Intermessage DelayNone *1~99(×5)msIntercharacter DelayNone *1~99(×5)msInterfunction DelayNone *1~99(×5)ms |
| Record Suffix (KB)PID : 01h 00hSize : 00h 02h (2 Bytes) | 1^st ~ 2^nd Byte- FFh FFh- 0Dh FFh- 09h FFh- 20h FFh- FEh FFh- XXh FFh | NoneCR (0Dh) *TAB (09h)SPACE (20h)ENTER (Numeric Key Pad)User-defined one ASCII character (XXh) |
| Record Suffix (Serial)PID : 01h 00hSize : 00h 02h (2 Bytes) | 1^st ~ 2^nd Byte- FFh FFh- 0Dh FFh- 0Ah FFh- 0Dh 0Ah- 09h FFh- 20h FFh- XXh FFh | NoneCR (0Dh) *LF (0Ah)CR (0Dh) LF (0Ah)TAB (09h)SPACE (20h)User-defined one ASCII character (XXh) |
| PreamblePID : 01h 01hSize : 00h 10h (16 Bytes) | 1^st Byte- XXh 2^nd ~ 16^th Byte- XXh XXh...XXh | Total number of the Preamble characters1~15 character(s) (See Note) |
| PostamblePID : 01h 02hSize : 00h 10h (16 Bytes) | 1^st Byte- XXh 2^nd ~ 16^th Byte- XXh XXh...XXh | Total number of the Postamble characters1~15 character(s) (See Note) |
| Symbol ID TransmissionPID : 01h 03hSize : 00h 01h (1 Byte) | - 00h- 01h- 02h- 03h- 04h- 05h- 06h | Disable *Enable prefix IDEnable suffix IDEnable both prefix and suffix IDEnable prefix AIM IDEnable suffix AIM IDEnable both prefix and suffix AIM ID |
.Notes
- Intercharacter Delay, Interfunction Delay settings are not available for serial communications via USB Virtual COM port.
- Preamble/ Postamble 2^nd 16^th byte: If the desired ASCII characters for setting the Preamble/ Postamble are shorter than 15 bytes, the rest bytes should be set to 00h.
Parameter(s)
< Table 7-1-1 > Set Transmission Parameter(s) Field (Continued)
| Parameter / PID / Size Options Descriptions | ||
| Data Script Active SettingPID : 02h 00hSize : 00h 01h (1 Byte) | - 01h- 02h......- 10h | (See Note)Active 1st Data Script *Active 2nd Data Script......Active 16th Data Script |
| Data Script SettingPID : 02h 01hSize : 00h 01h (1 Byte) | Bit 1- 0- 1Bit 0, Bit 2 ~ 7 | Data Script (See Note)Disable *EnableReserved |
| Security Script SettingPID : 02h 02hSize : 00h 01h (1 Byte) | - 00h- 01h | (See Note)Disable Security Script *Enable Security Script |
| DataWizard Premium Error MessagePID : 02h 03hSize : 00h 01h (1 Byte) | - 00h- 01h | (See Note)Disable Error Message *Enable Error Message |
.Notes
- Data Script Active Setting, Data Script Setting, Security Script Setting and Data Wizard Premium Error Message are all DataWizard Premium parameters which are available for Scanners that support DataWizard Premium. For more details about DataWizard Premium, please refer to FuzzyScan DataWizard Premium User Manual.
Get Transmission (ALL)
Descriptions
Request the desired one or more parameters of the Transmission settings as well as DataWizard Premium parameters including Data Script Active Setting, Data Script Setting, Security Script Setting and Data Wizard Premium Error Message.
DataWizard Premium parameters are only available for Scanners that support DataWizard Premium. For more details about DataWizard Premium, please refer to FuzzyScan DataWizard Premium User Manual.
Packet Format
| Prefix | Opcode | Status | Length | Parameter(s) | LRC | Suffix | |||
| 7Eh | CCh | 00h | 00h | Variable | See Below | Variable | 7Eh | ||
| 1 Byte | 3 | Bytes | 1 Byte | 2 Bytes | Variable | 1 Byte | 1 Byte | ||
| Parameter(s) | |||||||||
| First Parameter | ...... | Last Parameter | |||||||
| PID Size | ...... | PID Size | |||||||
| 2 Bytes | 2 Bytes | ...... | 2 Bytes | 2 Bytes | |||||
| See Next Page | |||||||||
. Host Requirements
If the device successfully received the above command issued by the host, the device will pack all requested parameters into a "Reply Transmission" message string then send to the host. Please refer to the "Reply Transmission" command for details. Otherwise, a "Device NAK" will be sent to host to indicate issue a command error. However, if the host can receive any response from the device within the user preset time-out duration, please resend the above command.
. Parameter(s) Field
Get Transmission can request multiple parameters at one time, so it takes compound parameters.
. Length
Total size (bytes) of the Parameter(s) field
.LRC
"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"
. Size
Total size (bytes) of the Options field
Parameter(s)
< Table 7-1-2 > Get Transmission Parameter(s) Field
| Parameter PID Size | ||
| Interface Delay Settings 00h 00h | 00h 00h | |
| Record Suffix 01h 00h | 00h 00h | |
| Preamble 01h 01h | 00h 00h | |
| Postamble 01h 02h | 00h 00h | |
| Symbology ID Transmission 01h 03h | 00h 00h | |
| Data Script Active Setting 02h 00h | 00h 00h | |
| Data Script Setting 02h 01h | 00h 00h | |
| Security Script Setting 02h 02h | 00h 00h | |
| DataWizard Premium Error Message 02h 03h | 00h 00h |
Reply Transmission (ALL)
Descriptions
Reply the desired one or more parameters of the Transmission settings as well as DataWizard Premium parameters including Data Script Active Setting, Data Script Setting, Security Script Setting and Data Wizard Premium Error Message.
Reply Transmission is sent by the device in response to the Get Transmission command. It sends the values for all the desired parameters requested in the Get Transmission command.
DataWizard Premium parameters are only available for Scanners that support DataWizard Premium. For more details about DataWizard Premium, please refer to FuzzyScan DataWizard Premium User Manual.
Packet Format
| Prefix | Opcode | Status | Length | Parameter(s) | LRC | Suffix | |||
| 7Eh | 0Dh | 00h 00h | 00h | Variable | See Below Variable | 7Eh | |||
| 1 Byte | 3 | Bytes | 1 Byte | 2 Bytes | Variable | 1 Byte | 1 Byte | ||
| Parameter(s) | |||||||||
| First Parameter | ...... | Last Parameter | |||||||
| PID | Size | Options | ...... | PID | Size | Options | |||
| 2 Bytes | 2 Bytes | Variable | ...... | 2 Bytes | 2 Bytes | Variable | |||
| See Next Page | |||||||||
. Host Requirements
Since Reply Transmission is a device-to-host message, there is no response for this message.
. Parameter(s) Field
Reply Transmission can change multiple parameters at one time, so it takes compound parameters.
. Length
Total size (bytes) of the Parameter(s) field
.LRC
"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"
. Size
Total size (bytes) of the Options field
Parameter(s)
< Table 7-1-3 > Reply Transmission Parameter(s) Field
| Parameter / PID / Size Options Descriptions | ||
| Interface Delay SettingsPID : 00h 00hSize : 00h 03h (3 Bytes) | 1^st Byte- 00h- 01h~63h 2^nd Byte- 00h- 01h~63h 3^rd Byte- 00h- 01h~63h | Intermessage DelayNone *1~99(×5)msIntercharacter DelayNone *1~99(×5)msInterfunction DelayNone *1~99(×5)ms |
| Record Suffix (KB)PID : 01h 00hSize : 00h 02h (2 Bytes) | 1^st ~ 2^nd Byte- FFh FFh- 0Dh FFh- 09h FFh- 20h FFh- FEh FFh- XXh FFh | NoneCR (0Dh) *TAB (09h)SPACE (20h)ENTER (Numeric Key Pad)User-defined one ASCII character (XXh) |
| Record Suffix (Serial)PID : 01h 00hSize : 00h 02h (2 Bytes) | 1^st ~ 2^nd Byte- FFh FFh- 0Dh FFh- 0Ah FFh- 0Dh 0Ah- 09h FFh- 20h FFh- XXh FFh | NoneCR (0Dh) *LF (0Ah)CR (0Dh) LF (0Ah)TAB (09h)SPACE (20h)User-defined one ASCII character (XXh) |
| PreamblePID : 01h 01hSize : 00h 10h (16 Bytes) | 1^st Byte- XXh 2^nd ~ 16^th Byte- XXh XXh...XXh | Total number of the Preamble characters1~15 character(s) (See Note) |
| PostamblePID : 01h 02hSize : 00h 10h (16 Bytes) | 1^st Byte- XXh 2^nd ~ 16^th Byte- XXh XXh...XXh | Total number of the Postamble characters1~15 character(s) (See Note) |
| Symbol ID TransmissionPID : 01h 03hSize : 00h 01h (1 Byte) | - 00h- 01h- 02h- 03h- 04h- 05h- 06h | Disable *Enable prefix IDEnable suffix IDEnable both prefix and suffix IDEnable prefix AIM IDEnable suffix AIM IDEnable both prefix and suffix AIM ID |
Notes
- Intercharacter Delay, Interfunction Delay settings are not available for serial communications via USB Virtual COM port.
- Preamble/ Postamble: If the desired ASCII characters for setting the Preamble/ Postamble are shorter than 15 bytes, the rest bytes should be set to 00h.
Parameter(s)
< Table 7-1-3 > Reply Transmission Parameter(s) Field (Continued)
| Parameter / PID / Size Options Descriptions | ||
| Data Script Active SettingPID : 02h 00hSize : 00h 01h (1 Byte) | - 01h- 02h......- 10h | (See Note)Active 1st Data Script *Active 2nd Data Script......Active 16th Data Script |
| Data Script SettingPID : 02h 01hSize : 00h 01h (1 Byte) | Bit 1- 0- 1Bit 0, Bit 2 ~ 7 | Data Script (See Note)Disable *EnableReserved |
| Security Script SettingPID : 02h 02hSize : 00h 01h (1 Byte) | - 00h- 01h | (See Note)Disable Security Script *Enable Security Script |
| DataWizard Premium Error MessagePID : 02h 03hSize : 00h 01h (1 Byte) | - 00h- 01h | (See Note)Disable Error Message *Enable Error Message |
.Notes
- Data Script Active Setting, Data Script Setting, Security Script Setting and Data Wizard Premium Error Message are all DataWizard Premium parameters which are available for Scanners that support DataWizard Premium. For more details about DataWizard Premium, please refer to FuzzyScan DataWizard Premium User Manual.
Set Transmission (WF)
Descriptions
Change the desired one or more parameters of the Transmission settings as well as DataWizard Premium parameters including Data Script Active Setting, Data Script Setting, Security Script Setting and Data Wizard Premium Error Message.
Available for F & L series
Note that DataWizard Premium parameters are only available for Scanners that support DataWizard Premium. For more details about DataWizard Premium, please refer to FuzzyScan DataWizard Premium User Manual.
Packet Format
| Prefix | Opcode | Status | Length | Parameter(s) | LRC | Suffix | |||
| 7Eh | 8Bh | 00h | 00h | Variable | See Below | Variable | 7Eh | ||
| 1 Byte | 3 | Bytes | 1 Byte | 2 Bytes | Variable | 1 Byte | 1 Byte | ||
| Parameter(s) | |||||||||
| First Parameter | ...... | Last Parameter | |||||||
| PID | Size | Options | ...... | PID | Size | Options | |||
| 2 Bytes | 2 Bytes | Variable | ...... | 2 Bytes | 2 Bytes | Variable | |||
| See Next Page | |||||||||
. Host Requirements
If the device successfully received the above command issued by the host, a "Device ACK" will send to the host right after the device performed the action. Otherwise, a "Device NAK" will be sent to host to issue a command error. However, if the host can not receive any response from the device within the user preset time-out duration, please resend the above command.
. Parameter(s) Field
Set Transmission can change multiple parameters at one time, so it takes compound parameters.
.Length
Total size (bytes) of the Parameter(s) field
.LRC
"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"
. Size
Total size (bytes) of the Options field
Parameter(s)
< Table 7-1-1 > Set Transmission Parameter(s) Field
| Parameter / PID / Size Options Descriptions | ||
| Interface Delay SettingsPID : 00h 00hSize : 00h 03h (3 Bytes) | 1^st Byte- 00h- 01h~63h 2^nd Byte- 00h- 01h~63h 3^rd Byte- 00h- 01h~63h | Intermessage DelayNone *1~99(×5)msIntercharacter DelayNone *1~99(×5)msInterfunction DelayNone *1~99(×5)ms |
| PreamblePID : 01h 01hSize : 00h 10h (16 Bytes) | 1^st Byte- XXh 2^nd ~ 16^th Byte- XXh XXh...XXh | Total number of the Preamble characters1~15 character(s) (See Note) |
| PostamblePID : 01h 02hSize : 00h 10h (16 Bytes) | 1^st Byte- XXh 2^nd ~ 16^th Byte- XXh XXh...XXh | Total number of the Postamble characters1~15 character(s) (See Note) |
| Symbol ID TransmissionPID : 01h 03hSize : 00h 01h (1 Byte) | - 00h- 01h- 02h- 03h- 04h- 05h- 06h | Disable *Enable prefix IDEnable suffix IDEnable both prefix and suffix IDEnable prefix AIM IDEnable suffix AIM IDEnable both prefix and suffix AIM ID |
.Notes
- Intercharacter Delay, Interfunction Delay settings are not available for serial communications via USB Virtual COM port.
- Preamble/ Postamble 2^nd 16^th byte: If the desired ASCII characters for setting the Preamble/ Postamble are shorter than 15 bytes, the rest bytes should be set to 00h.
Parameter(s)
< Table 7-1-1 > Set Transmission Parameter(s) Field (Continued)
| Parameter / PID / Size Options Descriptions | ||
| Data Script Active SettingPID : 02h 00hSize : 00h 01h (1 Byte) | - 01h- 02h......- 10h | (See Note)Active 1st Data Script *Active 2nd Data Script......Active 16th Data Script |
| Data Script SettingPID : 02h 01hSize : 00h 01h (1 Byte) | Bit 1- 0- 1Bit 0, Bit 2 ~ 7 | Data Script (See Note)Disable *EnableReserved |
| Security Script SettingPID : 02h 02hSize : 00h 01h (1 Byte) | - 00h- 01h | (See Note)Disable Security Script *Enable Security Script |
| DataWizard Premium Error MessagePID : 02h 03hSize : 00h 01h (1 Byte) | - 00h- 01h | (See Note)Disable Error Message *Enable Error Message |
.Notes
- Data Script Active Setting, Data Script Setting, Security Script Setting and Data Wizard Premium Error Message are all DataWizard Premium parameters which are available for Scanners that support DataWizard Premium. For more details about DataWizard Premium, please refer to FuzzyScan DataWizard Premium User Manual.
Get Transmission (WF)
Descriptions
Request the desired one or more parameters of the Transmission settings as well as DataWizard Premium parameters including Data Script Active Setting, Data Script Setting, Security Script Setting and Data Wizard Premium Error Message.
Available for F & L series
Note that DataWizard Premium parameters are only available for Scanners that support DataWizard Premium. For more details about DataWizard Premium, please refer to FuzzyScan DataWizard Premium User Manual.
Packet Format
| Prefix | Opcode | Status | Length | Parameter(s) | LRC | Suffix | |||
| 7Eh | CCh | 00h | 00h | Variable | See Below | Variable | 7Eh | ||
| 1 Byte | 3 | Bytes | 1 Byte | 2 Bytes | Variable | 1 Byte | 1 Byte | ||
| Parameter(s) | |||||||||
| First Parameter | ...... | Last Parameter | |||||||
| PID Size | ...... | PID Size | |||||||
| 2 Bytes | 2 Bytes | ...... | 2 Bytes | 2 Bytes | |||||
| See Next Page | |||||||||
. Host Requirements
If the device successfully received the above command issued by the host, the device will pack all requested parameters into a "Reply Transmission" message string then send to the host. Please refer to the "Reply Transmission" command for details. Otherwise, a "Device NAK" will be sent to host to indicate issue a command error. However, if the host can receive any response from the device within the user preset time-out duration, please resend the above command.
. Parameter(s) Field
Get Transmission can request multiple parameters at one time, so it takes compound parameters.
. Length
Total size (bytes) of the Parameter(s) field
.LRC
"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"
. Size
Total size (bytes) of the Options field
Parameter(s)
< Table 7-1-2 > Get Transmission Parameter(s) Field
| Parameter PID Size | ||
| Interface Delay Settings 00h 00h | 00h 00h | |
| Preamble 01h 01h | 00h 00h | |
| Postamble 01h 02h | 00h 00h | |
| Symbology ID Transmission 01h 03h | 00h 00h | |
| Data Script Active Setting 02h 00h | 00h 00h | |
| Data Script Setting 02h 01h | 00h 00h | |
| Security Script Setting 02h 02h | 00h 00h | |
| DataWizard Premium Error Message 02h 03h | 00h 00h |
Reply Transmission (WF)
Descriptions
Reply the desired one or more parameters of the Transmission settings as well as DataWizard Premium parameters including Data Script Active Setting, Data Script Setting, Security Script Setting and Data Wizard Premium Error Message.
Reply Transmission is sent by the device in response to the Get Transmission command. It sends the values for all the desired parameters requested in the Get Transmission command.
Available for F & L series
Note that DataWizard Premium parameters are only available for Scanners that support DataWizard Premium. For more details about DataWizard Premium, please refer to FuzzyScan DataWizard Premium User Manual.
Packet Format
| Prefix | Opcode Status Length | Parameter(s) LRC Suffix | ||||||
| 7Eh | 0Dh 00h 00h | 00h Variable | See Below Variable | 7Eh | ||||
| 1 Byte | 3 Bytes | 1 Byte | 2 Bytes | Variable | 1 Byte | 1 Byte | ||
| Parameter(s) | ||||||||
| First Parameter | ...... | Last Parameter | ||||||
| PID | Size | Options | ...... | PID | Size | Options | ||
| 2 Bytes | 2 Bytes | Variable | ...... | 2 Bytes | 2 Bytes | Variable | ||
| See Next Page | ||||||||
. Host Requirements
Since Reply Transmission is a device-to-host message, there is no response for this message.
. Parameter(s) Field
Reply Transmission can change multiple parameters at one time, so it takes compound parameters.
. Length
Total size (bytes) of the Parameter(s) field
.LRC
"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"
. Size
Total size (bytes) of the Options field
Parameter(s)
< Table 7-1-3 > Reply Transmission Parameter(s) Field (To be continued)
| Parameter / PID / Size Options Descriptions | ||
| Interface Delay SettingsPID : 00h 00hSize : 00h 03h (3 Bytes) | 1^st Byte- 00h- 01h~63h 2^nd Byte- 00h- 01h~63h 3^rd Byte- 00h- 01h~63h | Intermessage DelayNone *1~99(×5)msIntercharacter DelayNone *1~99(×5)msInterfunction DelayNone *1~99(×5)ms |
| PreamblePID : 01h 01hSize : 00h 10h (16 Bytes) | 1^st Byte- XXh 2^nd ~ 16^th Byte- XXh XXh...XXh | Total number of the Preamble characters1~15 character(s) (See Note) |
| PostamblePID : 01h 02hSize : 00h 10h (16 Bytes) | 1^st Byte- XXh 2^nd ~ 16^th Byte- XXh XXh...XXh | Total number of the Postamble characters1~15 character(s) (See Note) |
| Symbol ID TransmissionPID : 01h 03hSize : 00h 01h (1 Byte) | - 00h- 01h- 02h- 03h- 04h- 05h- 06h | Disable *Enable prefix IDEnable suffix IDEnable both prefix and suffix IDEnable prefix AIM IDEnable suffix AIM IDEnable both prefix and suffix AIM ID |
.Notes
- Intercharacter Delay, Interfunction Delay settings are not available for serial communications via USB Virtual COM port.
- Preamble/ Postamble: If the desired ASCII characters for setting the Preamble/ Postamble are shorter than 15 bytes, the rest bytes should be set to 00h.
Parameter(s)
< Table 7-1-3 > Reply Transmission Parameter(s) Field (Continued)
| Parameter / PID / Size Options Descriptions | ||
| Data Script Active SettingPID : 02h 00hSize : 00h 01h (1 Byte) | - 01h- 02h......- 10h | (See Note)Active 1st Data Script *Active 2nd Data Script......Active 16th Data Script |
| Data Script SettingPID : 02h 01hSize : 00h 01h (1 Byte) | Bit 1- 0- 1Bit 0, Bit 2 ~ 7 | Data Script (See Note)Disable *EnableReserved |
| Security Script SettingPID : 02h 02hSize : 00h 01h (1 Byte) | - 00h- 01h | (See Note)Disable Security Script *Enable Security Script |
| DataWizard Premium Error MessagePID : 02h 03hSize : 00h 01h (1 Byte) | - 00h- 01h | (See Note)Disable Error Message *Enable Error Message |
.Notes
- Data Script Active Setting, Data Script Setting, Security Script Setting and Data Wizard Premium Error Message are all DataWizard Premium parameters which are available for Scanners that support DataWizard Premium. For more details about DataWizard Premium, please refer to FuzzyScan DataWizard Premium User Manual.
2.8 Symbology
Set Symbology (ALL)
Descriptions
Change the desired one or more parameters of the Symbology settings
Packet Format
| Prefix | Opcode | Status | Length | Parameter(s) | LRC | Suffix | |||
| 7Eh | 85h | 00h | 00h | Variable | See Below | Variable | 7Eh | ||
| 1 Byte | 3 | Bytes | 1 Byte | 2 Bytes | Variable | 1 Byte | 1 Byte | ||
| Parameter(s) | |||||||||
| First Parameter ...... | Last Parameter | ||||||||
| PID | Size | Options | ...... | PID | Size | Options | |||
| 2 Bytes | 2 Bytes | Variable | ...... | 2 Bytes | 2 Bytes | Variable | |||
| See Next Page | |||||||||
. Host Requirements
If the device successfully received the above command issued by the host, a "Device ACK" will send to the host right after the device performed the action. Otherwise, a "Device NAK" will be sent to host to issue a command error. However, if the host can not receive any response from the device within the user preset time-out duration, please resend the above command.
. Parameter(s) Field
Set Symbology can change multiple parameters at one time, so it takes compound parameters.
. Length
Total size (bytes) of the Parameter(s) field
.LRC
"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"
. Size
Total size (bytes) of the Options field
Parameter(s)
< Table 8-1-1 > Set Symbology Parameter(s) Field (To be continued)
| Parameter / PID / Size Options Descriptions | ||
| Code 39 ReadabilityPID : 00h 00hSize : 00h 01h (1 Byte) | - 00h- 01h | DisableEnable * |
| Code 39 SettingPID : 00h 01hSize : 00h 06h (6 Bytes) | 1^st Byte- 00h- 01h- 02h 2^nd Byte- 00h- 01h 3^rd Byte- 00h- 01h 4^th Byte- 00h- 01h 5^th Byte- 00h- 01h 6^th Byte- 00h- 01h | Primary Format SelectionStandard Code 39 *Full ASCII Code 39Code 32 (Italian Pharmaceutical)Start/ Stop Symbol TransmissionDisable *EnableCode 32 Leading A TransmissionDisable *EnableMOD 43 Check Digit VerificationDisable *EnableCheck Digit TransmissionDisable *EnableCode 39 BufferingDisable *Enable |
| Code 39 LengthPID : 00h 02hSize : 00h 02h (2 Bytes) | 1^st Byte- 01h~62h 2^nd Byte- 62h~01h | Minimum Length1~98 (Default: 1)Maximum Length98~1 (Default: 98) |
| Trioptic Code 39 ReadabilityPID : 00h 03hSize : 00h 01h (1 Byte) | - 00h- 01h | Disable *Enable |
| Code 39 Security LevelPID : 00h 04hSize : 00h 01h (1 Byte) | - 00h- 01h- 02h- 03h | Level 0Level 1Level 2 *Level 3 |
Parameter(s)
< Table 8-1-1 > Set Symbology Parameter(s) Field (Continued)
| Parameter / PID / Size Options Descriptions | ||
| Codabar ReadabilityPID : 01h 00hSize : 00h 01h (1 Byte) | - 00h- 01h | DisableEnable * |
| Codabar SettingsPID : 01h 01hSize : 00h 04h (4 Bytes) | 1^st Byte- 00h- 01h- 02h- 03h 2^nd Byte- 00h- 01h- 02h- 03h- 04h 3^rd Byte- 00h- 01h 4^th Byte- 00h- 01h | Primary Format SelectionCodabar Standard format *Codabar ABC formatCodabar CLSI formatCodabar CX formatStart/ Stop Symbol TransmissionDisable *Enable ABCD/ABCDEnable abcd/abcdEnable ABCD/TN*EEnable abcd/tn*eCheck Digit VerificationDisable *EnableCheck Digit TransmissionDisable *Enable |
| Codabar LengthPID : 01h 02hSize : 00h 02h (2 Bytes) | 1^st Byte- 01h~62h 2^nd Byte- 62h~01h | Minimum Length1~98 (Default: 4)Maximum Length98~1 (Default: 98) |
| Codabar Check DigitPID : 01h 03hSize : 00h 01h (1 Byte) | - 00h- 01h- 02h- 03h- 04h- 05h- 06h | Modulus 16*Modulus 10/Weight 3Modulus 11Modulus 10/Weight 27 Check DRWeight Modulus 11Runes (Modulus 10/Weight 2) |
Parameter(s)
< Table 8-1-1 > Set Symbology Parameter(s) Field (Continued)
| Parameter / PID / Size Options Descriptions | ||
| UPC-A/UPC-E ReadabilityPID: 02h 00hSize: 00h 02h (2 Bytes) | 1^st Byte- 00h- 01h 2^nd Byte- 00h- 01h | UPC-A ReadabilityDisableEnable *UPC-E ReadabilityDisableEnable * |
| UPC-A/UPC-E SettingPID: 02h 01hSize: 00h 06h (6 Bytes) | 1^st Byte- 00h- 01h 2^nd Byte- 00h- 01h 3^rd Byte- 00h- 01h 4^th Byte- 00h- 01h 5^th Byte- 00h- 01h 6^th Byte- 00h- 01h | UPC-E ExpansionDisable *EnableUPC StandardizationDisable *EnableUPC Numeric SystemDisableEnable *UPC-A Check Digit TransmissionDisableEnable *UPC-E Check Digit TransmissionDisableEnable *UPC "leading 1" PortionDisable *Enable |
| UPC-A/UPC-E SupplementPID: 02h 02hSize: 00h 03h (3 Bytes) | 1^st Byte- 00h- 01h- 02h- 03h 2^nd Byte- 00h- 01h 3^rd Byte- 00h- 01h | Supplement Digits SelectionWithout *With only 2 supplement digitsWith only 5 supplement digitsWith 2/5 supplement digitsForce Supplement Digits OutputDisable *EnableUPC Family Addenda SeparatorDisable *Enable |
Parameter(s)
< Table 8-1-1 > Set Symbology Parameter(s) Field (Continued)
| Parameter / PID / Size Options Descriptions | ||
| EAN-13/EAN-8 ReadabilityPID : 03h 00hSize : 00h 02h (2 Bytes) | 1^st Byte- 00h- 01h 2^nd Byte- 00h- 01h | EAN/JAN-13 ReadabilityDisableEnable *EAN/JAN-8 ReadabilityDisableEnable * |
| EAN-13/EAN-8 SettingPID : 03h 01hSize : 00h 04h (4 Bytes) | 1^st Byte- 00h- 01h 2^nd Byte- 00h- 01h 3^rd Byte- 00h- 01h 4^th Byte- 00h- 01h | EAN-8 ExpansionDisable *EnableEAN-13 Check Digit TransmissionDisableEnable *EAN-8 Check Digit TransmissionDisableEnable *ISBN/ISSN Reading CheckDisable *Enable |
| EAN-13/EAN-8 SupplementPID : 03h 02hSize : 00h 03h (3 Bytes) | 1^st Byte- 00h- 01h- 02h- 03h 2^nd Byte- 00h- 01h 3^rd Byte- 00h- 01h | Supplement Digits SelectionWithout *With only 2 supplement digitsWith only 5 supplement digitsWith 2/5 supplement digitsForce Supplement Digits OutputDisable *EnableEAN Family Addenda SeparatorDisable *Enable |
| EAN Supplement ControlPID : 03h 04hSize : 00h 01h (1 Byte) | - 00h- 01h- 02h- 03h- 04h- 05h- 06h- 07h | Disable All Specific Prefix Supplement Output *Enable All Specific Prefix Supplement OutputEnable 491 Supplement OutputEnable 978/979 Supplement OutputEnable 977 Supplement OutputEnable 378/379 Supplement OutputEnable 414/419 Supplement OutputEnable 434/439 Supplement Output |
| UCC Coupon Extended Code ReadabilityPID : 03h 03hSize : 00h 01h (1 Byte) | - 00h- 01h | Disable*Enable |
Parameter(s)
< Table 8-1-1 > Set Symbology Parameter(s) Field (Continued)
| Parameter / PID / Size Options Descriptions | ||
| IATA ReadabilityPID: 04h 00hSize: 00h 01h (1 Byte) | - 00h- 01h | Disable *Enable |
| IATA SettingPID: 04h 01hSize: 00h 04h (4 Bytes) | 1^st Byte- 00h- 01h 2^nd Byte- 00h- 01h- 02h- 03h- 04h 3^rd Byte- 00h- 01h 4^th Byte- 00h- 01h | IATA Checking Selection15-digit fixed length IATA checking*Variable length IATA checkingCheck Digit VerificationDisable *check digit automatic verificationS/N checking digit verification onlyCPN checking digit verification onlyCPN, Airline and S/N check digit verificationCheck Digit TransmissionDisable*EnableStart/Stop Symbol TransmissionDisable *Enable |
| Interleaved 2 of 5 ReadabilityPID: 04h 02hSize: 00h 01h (1 Byte) | - 00h- 01h | DisableEnable * |
| Interleaved 2 of 5 SettingsPID: 04h 03hSize: 00h 03h (3 Bytes) | 1^st Byte- 00h- 01h 2^nd Byte- 00h- 01h- 02h 3^rd Byte- 00h- 01h | Decoding Format SelectionInterleaved 2 of 5 *German Postal CodeUSS/OPCC Check Digit VerificationDisable *USS check digitOPCC check digitCheck Digit TransmissionDisable *Enable |
| Standard/Industrial 2 of 5 ReadabilityPID: 04h 04hSize: 00h 01h (1 Byte) | - 00h- 01h | Disable *Enable |
| Matrix 2 of 5 ReadabilityPID: 04h 05hSize: 00h 01h (1 Byte) | - 00h- 01h | Disable *Enable |
| China Postal Code ReadabilityPID: 04h 06hSize: 00h 01h (1 Byte) | - 00h- 01h | Disable *Enable |
Parameter(s)
< Table 8-1-1 > Set Symbology Parameter(s) Field (To be continued)
| Parameter / PID / Size Options Descriptions | ||
| Code 25 SettingPID:04h 07hSize:00h 02h (2 Bytes) | 1^st Byte-00h-01h 2^nd Byte-00h-01h | Check Digit VerificationDisable *EnableCheck Digit TransmissionDisable *Enable |
| Code 25 LengthPID:04h 08hSize:00h 02h (2 Bytes) | 1^st Byte-01h~62h 2^nd Byte-62h~01h | Minimum Length1~98 (Default: 4)Maximum Length98~1 (Default: 98) |
| Code 11 ReadabilityPID:05h 00hSize:00h 01h (1 Byte) | -00h-01h | Disable *Enable |
| Code 11 SettingPID:05h 01hSize:00h 02h (2 Bytes) | 1^st Byte-00h-01h-02h 2^nd Byte-00h-01h | Check Digit VerificationDisable *1-check digit verification2-check digit verificationCheck Digit TransmissionDisable *Enable |
| Code 11 LengthPID:05h 02hSize:00h 02h (2 Bytes) | 1^st Byte-01h~62h 2^nd Byte-62h~01h | Minimum Length1~98 (Default: 4)Maximum Length98~1 (Default: 98) |
| Code 93 ReadabilityPID:06h 00hSize:00h 01h (1 Byte) | -00h-01h | DisableEnable * |
| Code 93 Check Digit TransmissionPID:06h 01hSize:00h 01h (1 Byte) | -00h-01h | Disable *Enable |
| Code 93 LengthPID:06h 02hSize:00h 02h (2 Bytes) | 1^st Byte-01h~62h 2^nd Byte-62h~01h | Minimum Length1~98 (Default: 1)Maximum Length98~1 (Default: 98) |
Parameter(s)
< Table 8-1-1 > Set Symbology Parameter(s) Field (Continued)
| Parameter / PID / Size Options Descriptions | ||
| MSI/Plessey ReadabilityPID : 07h 00hSize : 00h 01h (1 Byte) | - 00h- 01h | Disable *Enable |
| MSI/Plessey SettingPID : 07h 01hSize : 00h 02h (2 Bytes) | 1^st Byte- 00h- 01h- 02h 2^nd Byte- 00h- 01h | Check Digit SelectionMOD 10 check digit *MOD 10-10 check digitMOD 11-10 check digitCheck Digit TransmissionDisable *Enable |
| MSI/Plessey LengthPID : 07h 02hSize : 00h 02h (2 Bytes) | 1^st Byte- 01h~62h 2^nd Byte- 62h~01h | Minimum Length1~98 (Default: 4)Maximum Length98~1 (Default: 98) |
| Code 128/EAN-128 ReadabilityPID : 08h 00hSize : 00h 01h (1 Byte) | - 00h- 01h | DisableEnable * |
| Code 128/EAN-128 SettingPID : 08h 01hSize : 00h 01 (1 Byte) | - 00h- 01h | ISBT Concatenation Off *ISBT Concatenation On |
| Code 128/EAN-128 LengthPID : 08h 02hSize : 00h 02h (2 Bytes) | 1^st Byte- 01h~62h 2^nd Byte- 62h~01h | Minimum Length1~98 (Default: 1)Maximum Length98~1 (Default: 98) |
| Code 128/EAN-128 Security LevelPID : 08h 03hSize : 00h 01h (1 Byte) | - 00h- 01h | Level 0Level 1 * |
| GS1-128 ReadabilityPID : 08h 04hSize : 00h 01h (1 Byte) | - 00h- 01h | DisableEnable * |
| GS1-128 LengthPID : 08h 05hSize : 00h 02h (2 Bytes) | 1^st Byte- 01h~62h 2^nd Byte- 62h~01h | Minimum Length1~98 (Default: 1)Maximum Length98~1 (Default: 98) |
Parameter(s)
< Table 8-1-1 > Set Symbology Parameter(s) Field (Continued)
| Parameter / PID / Size Options Descriptions | ||
| UK/Plessey ReadabilityPID: 09h 00hSize: 00h 01h (1 Byte) | - 00h- 01h | Disable *Enable |
| UK/Plessey SettingPID: 09h 01hSize: 00h 03h (3 Bytes) | 1^st Byte- 00h- 01h 2^nd Byte- 00h- 01h 3^rd Byte- 00h- 01h | Primary Format SelectionStandard *CLSIConvert X to A-FDisable *EnableCheck Digit TransmissionDisable *Enable |
| UK/Plessey LengthPID: 09h 02hSize: 00h 02h (2 Bytes) | 1^st Byte- 01h~62h 2^nd Byte- 62h~01h | Minimum Length1~98 (Default: 4)Maximum Length98~1 (Default: 98) |
| Telepen ReadabilityPID: 0Ah 00hSize: 00h 01h (1 Byte) | - 00h- 01h | Disable *Enable |
| Telepen SettingPID: 0Ah 01hSize: 00h 02h (2 Bytes) | 1^st Byte- 00h- 01h 2^nd Byte- 00h- 01h | Primary Format SelectionTelepen Full ASCII modeTelepen Numeric mode *Check Digit TransmissionDisable *Enable |
| Telepen LengthPID: 0Ah 02hSize: 00h 02h (2 Bytes) | 1^st Byte- 01h~62h 2^nd Byte- 62h~01h | Minimum Length1~98 (Default: 4)Maximum Length98~1 (Default: 98) |
| GS 1 DataBar ReadabilityPID: 20h 00hSize: 00h 03h (3 Bytes) | 1^st Byte- 00h- 01h 2^nd Byte- 00h- 01h 3^rd Byte- 00h- 01h | GS1 DataBar (RSS-14)DisableEnable *GS1 DataBar LimitedDisableEnable *GS1 DataBar ExpandedDisableEnable * |
| GS 1 DataBar Expanded LengthPID: 20h 01hSize: 00h 02h (2 Bytes) | 1^st Byte- 01h~4Ah 2^nd Byte- 4Ah~01h | Minimum Length1~74 (Default: 4)Maximum Length74~1 (Default: 74) |
Parameter(s)
< Table 8-1-1 > Set Symbology Parameter(s) Field (Continued)
| Parameter / PID / Size Options Descriptions | ||
| Composite Code ReadabilityPID : 21h 00hSize : 00h 01h (1 Byte) | - 00h- 01h | Disable *Enable |
| UPC Composite ModePID : 21h 01hSize : 00h 01h (1 Byte) | - 00h- 01h | Disable *Enable |
| PDF417/ Micro PDF417ReadabilityPID : 22h 00hSize : 00h 02h (2 Bytes) | 1^st Byte- 00h- 01h 2^nd Byte- 00h- 01h | PDF417 ReadabilityDisableEnable *Micro PDF417 ReadabilityDisable *Enable |
| Codablock F ReadabilityPID : 23h 00hSize : 00h 01h (1 Byte) | - 00h- 01h | Disable *Enable |
| Code 16K ReadabilityPID : 24h 00hSize : 00h 01h (1 Byte) | - 00h- 01h | Disable *Enable |
| Code 16K LengthPID : 24h 01hSize : 00h 02h (2 Bytes) | 1^st Byte- 01h~A0h 2^nd Byte- A0h~01h | Minimum Length1~160 (Default: 1)Maximum Length160~1 (Default: 160) |
| Code 49 ReadabilityPID : 25h 00hSize : 00h 01h (1 Byte) | - 00h- 01h | Disable *Enable |
| Code 49 LengthPID : 25h 01hSize : 00h 02h (2 Bytes) | 1^st Byte- 01h~51h 2^nd Byte- 51h~01h | Minimum Length1~81 (Default: 1)Maximum Length81~1 (Default: 81) |
Parameter(s)
< Table 8-1-1 > Set Symbology Parameter(s) Field (Continued)
| Parameter / PID / Size Options Descriptions | ||
| QR Code ReadabilityPID : 30h 00hSize : 00h 01h (1 Byte) | - 00h- 01h | DisableEnable * |
| Micro QR Code ReadabilityPID : 30h 01hSize : 00h 01h (1 Byte) | - 00h- 01h | DisableEnable * |
| QR Code SettingPID : 30h 02hSize : 00h 02h (2 Bytes) | 1^st Byte- 00h- 01h 2^nd Byte- 00h- 01h- 02h | QR Code AppendDisableEnable *QR Code Inverse ReadingDisable *EnableAuto Detect |
| QR Code LengthPID : 30h 03hSize : 00h 04h (4 Bytes) | 1^st & 2^nd Byte- 01h~1BB1h 3^rd & 4^th Byte- 1BB1h~01h | Minimum Length(Big Endian)1~7089 (Default: 1)Maximum Length(Big Endian)7089~1 (Default: 7089) |
| Data Matrix ReadabilityPID : 31h 00hSize : 00h 01h (1 Byte) | - 00h- 01h | DisableEnable * |
| Data Matrix SettingPID : 31h 01hSize : 00h 02h (2 Bytes) | 1^st Byte- 00h- 01h 2^nd Byte- 00h- 01h- 02h | Data Matrix AppendDisableEnable *Data Matrix Inverse ReadingDisable *EnableAuto Detect |
| Data Matrix LengthPID : 31h 02hSize : 00h 04h (4 Bytes) | 1^st & 2^nd Byte- 01h~C2Ch 3^rd & 4^th Byte- C2Ch~01h | Minimum Length(Big Endian)1~3116 (Default: 1)Maximum Length(Big Endian)3116~1 (Default: 3116) |
| MaxiCode ReadabilityPID : 32h 00hSize : 00h 01h (1 Byte) | - 00h- 01h | Disable *Enable |
| MaxiCode LengthPID : 32h 01hSize : 00h 02h (2 Bytes) | 1^st Byte- 01h~96h 2^nd Byte- 96h~01h | Minimum Length1~150 (Default: 1)Maximum Length150~1 (Default: 150) |
Parameter(s)
< Table 8-1-1 > Set Symbology Parameter(s) Field (Continued)
| Parameter / PID / Size Options Descriptions | ||
| Aztec ReadabilityPID : 33h 00hSize : 00h 01h (1 Byte) | - 00h- 01h | Disable *Enable |
| Aztec SettingPID : 33h 01hSize : 00h 02h (2 Bytes) | 1^st Byte- 00h- 01h 2^nd Byte- 00h- 01h- 02h | Aztec AppendDisable *EnableAztec Inverse ReadingDisable *EnableAuto Detect |
| Aztec LengthPID : 33h 02hSize : 00h 04h (4 Bytes) | 1^st & 2^nd Byte- 01h~EF8h 3^rd & 4^th Byte- EF8h~01h | Minimum Length(Big Endian)1~3832 (Default: 1)Maximum Length(Big Endian)3832 ~1 (Default: 3832) |
| Chinese Sensible ReadabilityPID : 34h 00hSize : 00h 01h (1 Byte) | - 00h- 01h | Disable *Enable |
| Chinese Sensible LengthPID : 34h 01hSize : 00h 04h (4 Bytes) | 1^st & 2^nd Byte- 01h~1E99h 3^rd & 4^th Byte- 1E99h~01h | Minimum Length(Big Endian)1~7833 (Default: 1)Maximum Length(Big Endian)7833~1 (Default: 7833) |
| Korea Post CodePID : 50h 00hSize : 00h 01h (1 Byte) | - 00h- 01h | Disable *Enable |
| Australian Post ReadabilityPID : 51h 00hSize : 00h 01h (1 Byte) | - 00h- 01h | Disable *Enable |
| Australian Post Output FormatPID : 51h 01hSize : 00h 03h (3 Bytes) | - 00h FFh FFh- 00h 00h 00h- 00h 7Fh FFh- 01h 00h FFh | Raw format Output *Numeric Encoding OutputAlphanumeric Encoding OutputAutodiscriminate Output |
| US Planet ReadabilityPID : 52h 00hSize : 00h 01h (1 Byte) | - 00h- 01h | Disable *Enable |
| US Planet Check DigitTransmissionPID : 52h 01hSize : 00h 01h (1 Byte) | - 00h- 01h | Disable *Enable |
Parameter(s)
< Table 8-1-1 > Set Symbology Parameter(s) Field (Continued)
| Parameter / PID / Size Options Descriptions | ||
| US Postnet ReadabilityPID : 53h 00hSize : 00h 01h (1 Byte) | - 00h- 01h | Disable *Enable |
| US Postnet Check Digit TransmissionPID : 53h 01hSize : 00h 01h (1 Byte) | - 00h- 01h | Disable *Enable |
| British Post ReadabilityPID : 54h 00hSize : 00h 01h (1 Byte) | - 00h- 01h | Disable *Enable |
| British Post Check Digit TransmissionPID : 54h 01hSize : 00h 01h (1 Byte) | - 00h- 01h | Disable *Enable |
| Japan Post ReadabilityPID : 55h 00hSize : 00h 01h (1 Byte) | - 00h- 01h | Disable *Enable |
| Netherlands KIX Code ReadabilityPID : 56h 00hSize : 00h 01h (1 Byte) | - 00h- 01h | Disable *Enable |
| Intelligent Mail ReadabilityPID : 57h 00hSize : 00h 01h (1 Byte) | - 00h- 01h | Disable *Enable |
Get Symbology (ALL)
Descriptions
Request the desired one or more parameters of the Symbology settings
Packet Format
| Prefix | Opcode | Status | Length | Parameter(s) | LRC | Suffix | |||
| 7Eh | C6h | 00h | 00h | Variable | See Below | Variable | 7Eh | ||
| 1 Byte | 3 | Bytes | 1 Byte | 2 Bytes | Variable | 1 Byte | 1 Byte | ||
| Parameter(s) | |||||||||
| First Parameter | ...... | Last Parameter | |||||||
| PID Size | PID Size | ||||||||
| 2 Bytes | 2 Bytes | ...... | 2 Bytes | 2 Bytes | |||||
| See Next Page | |||||||||
. Host Requirements
If the device successfully received the above command issued by the host, the device will pack all requested parameters into a "Reply Symbology" message string then send to the host. Please refer to the "Reply Symbology" command for details. Otherwise, a "Device NAK" will be sent to host to indicate issue a command error. However, if the host can receive any response from the device within the user preset time-out duration, please resend the above command.
. Parameter(s) Field
Get Symbology can request multiple parameters at one time, so it takes compound parameters.
. Length
Total size (bytes) of the Parameter(s) field
.LRC
"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"
. Size
Total size (bytes) of the Options field
Parameter(s)
< Table 8-1-2 > Get Symbology Parameter(s) Field (To be continued)
| Parameter PID Size | ||
| Code 39 Readability 00h 00h | 00h 00h | |
| Code 39 Setting 00h 01h | 00h 00h | |
| Code 39 Length 00h 02h | 00h 00h | |
| Trioptic Code 39 Readability 00h 03h | 00h 00h | |
| Code 39 Security Level 00h 04h | 00h 00h | |
| Codabar Readability 01h 00h | 00h 00h | |
| Codabar Settings 01h 01h | 00h 00h | |
| Codabar Length 01h 02h | 00h 00h | |
| Codabar Check Digit 01h 03h | 00h 00h | |
| UPC-A/UPC-E Readability 02h 00h | 00h 00h | |
| UPC-A/UPC-E Setting | 02h 01h | 00h 00h |
| UPC-A/UPC-E Supplement | 02h 02h | 00h 00h |
| EAN-13/EAN-8 Readability | 03h 00h | 00h 00h |
| EAN-13/EAN-8 Setting | 03h 01h | 00h 00h |
| EAN-13/EAN-8 Supplement | 03h 02h | 00h 00h |
| UCC Coupon Extended Code Readability | 03h 03h | 00h 00h |
| EAN Supplement Control | 03h 04h | 00h 00h |
| IATA Readability | 04h 00h | 00h 00h |
| IATA Setting | 04h 01h | 00h 00h |
| Interleaved 2 of 5 Readability | 04h 02h | 00h 00h |
| Interleaved 2 of 5 Settings | 04h 03h | 00h 00h |
| Standard/Industrial 2 of 5 Readability | 04h 04h | 00h 00h |
| Matrix 2 of 5 Readability | 04h 05h | 00h 00h |
| China Postal Code Readability | 04h 06h | 00h 00h |
| Code 25 Setting 04h 07h | 00h 00h | |
| Code 25 Length 04h 08h | 00h 00h | |
| Code 11 Readability | 05h 00h | 00h 00h |
| Code 11 Setting 05h 01h | 00h 00h | |
| Code 11 Length | 05h 02h | 00h 00h |
| Code 93 Readability 06h 00h | 00h 00h | |
| Code 93 Check Digit Transmission | 06h 01h | 00h 00h |
| Code 93 Length 06h 02h | 00h 00h | |
| MSI/Plessey Readability | 07h 00h | 00h 00h |
| MSI/Plessey Setting | 07h 01h | 00h 00h |
| MSI/Plessey Length | 07h 02h | 00h 00h |
Parameter(s)
< Table 8-1-2 > Get Symbology Parameter(s) Field (Continued)
| Parameter PID Size | ||
| Code 128/EAN-128 Readability 08h 00h | 00h 00h | |
| Code 128/EAN-128 Setting 08h 01h | 00h 00h | |
| Code 128/EAN-128 Length 08h 02h | 00h 00h | |
| Code 128/EAN-128 Security Level 08h 03h | 00h 00h | |
| GS1-128 Readability 08h 04h | 00h 00h | |
| GS1-128 Length 08h 05h | 00h 00h | |
| UK/Plessey Readability 09h 00h | 00h 00h | |
| UK/Plessey Setting 09h 01h | 00h 00h | |
| UK/Plessey Length 09h 02h | 00h 00h | |
| Telepen Readability | 0Ah 00h | 00h 00h |
| Telepen Setting | 0Ah 01h | 00h 00h |
| Telepen Length | 0Ah 02h | 00h 00h |
| GS 1 DataBar Readability | 20h 00h | 00h 00h |
| GS 1 DataBar Expanded Length | 20h 01h | 00h 00h |
| Composite Code Readability | 21h 00h | 00h 00h |
| UPC Composite Mode | 21h 01h | 00h 00h |
| PDF417/MicroPDF417 Readability 22h 00h | 00h 00h | |
| Codablock F Readability | 23h 00h | 00h 00h |
| Code 16K Readability | 24h 00h | 00h 00h |
| Code 16K Length | 24h 01h | 00h 00h |
| Code 49 Readability | 25h 00h | 00h 00h |
| Code 49 Length | 25h 01h | 00h 00h |
| QR Code Readability | 30h 00h | 00h 00h |
| Micro QR Code Readability | 30h 01h | 00h 00h |
| QR Code Setting | 30h 02h | 00h 00h |
| QR Code Length | 30h 03h | 00h 00h |
| Data Matrix Readability | 31h 00h | 00h 00h |
| Data Matrix Setting | 31h 01h | 00h 00h |
| Data Matrix Length | 31h 02h | 00h 00h |
| MaxiCode Readability | 32h 00h | 00h 00h |
| MaxiCode Length | 32h 01h | 00h 00h |
| Aztec Code Readability 33h 00h | 00h 00h | |
| Aztec Code Setting 33h 01h | 00h 00h | |
| Aztec Code Length 33h 02h | 00h 00h |
Parameter(s)
< Table 8-1-2 > Get Symbology Parameter(s) Field (Continued)
| Parameter PID Size | ||
| Chinese Sensible Readability 34h 00h | 00h 00h | |
| Chinese Sensible Length 34h 01h | 00h 00h | |
| Korea Post Code 50h 00h | 00h 00h | |
| Australian Post Readability 51h 00h | 00h 00h | |
| Australian Post Output Format 51h 01h | 00h 00h | |
| US Planet Readability 52h 00h | 00h 00h | |
| US Planet Check Digit Transmission 52h 01h | 00h 00h | |
| US Postnet Readability 53h 00h | 00h 00h | |
| US Postnet Check Digit Transmission 53h 01h | 00h 00h | |
| British Post Readability 54h 00h | 00h 00h | |
| British Post Check Digit Transmission | 54h 01h | 00h 00h |
| Japan Post Readability 55h 00h | 00h 00h | |
| Netherlands KIX Code Readability | 56h 00h | 00h 00h |
| Intelligent Mail Readability | 57h 00h | 00h 00h |
Reply Symbology (ALL)
Descriptions
Reply the desired one or more parameters of the Symbology settings
Reply Symbology is sent by the device in response to the Get Symbology command. It sends the values for all the desired parameters requested in the Get Symbology command.
Packet Format
| Prefix | Opcode | Status | Length | Parameter(s) | LRC | Suffix | ||
| 7Eh | 07h | 00h | 00h | Variable | See Below Variable | 7Eh | ||
| 1 Byte | 3 | Bytes | 1 Byte | 2 Bytes | / | Variable 1 Byte | 1 Byte | |
| Parameter(s) | ||||||
| First Parameter | ...... | Last Parameter | ||||
| PID | Size | Options | ...... | PID | Size | Options |
| 2 Bytes | 2 Bytes | Variable | ...... | 2 Bytes | 2 Bytes | Variable |
| See Next Page | ||||||
. Host Requirements
Since Reply Symbology is a device-to-host message, there is no response for this message.
. Parameter(s) Field
Set Symbology can change multiple parameters at one time, so it takes compound parameters.
. Length
Total size (bytes) of the Parameter(s) field
.LRC
"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"
. Size
Total size (bytes) of the Options field
Parameter(s)
< Table 8-1-3 > Reply Symbology Parameter(s) Field (To be continued)
| Parameter / PID / Size Options Descriptions | ||
| Code 39 ReadabilityPID : 00h 00hSize : 00h 01h (1 Byte) | - 00h- 01h | DisableEnable * |
| Code 39 SettingPID : 00h 01hSize : 00h 06h (6 Bytes) | 1^st Byte- 00h- 01h- 02h 2^nd Byte- 00h- 01h 3^rd Byte- 00h- 01h 4^th Byte- 00h- 01h 5^th Byte- 00h- 01h 6^th Byte- 00h- 01h | Primary Format SelectionStandard Code 39 *Full ASCII Code 39Code 32 (Italian Pharmaceutical)Start/ Stop Symbol TransmissionDisable *EnableCode 32 Leading A TransmissionDisable *EnableMOD 43 Check Digit VerificationDisable *EnableCheck Digit TransmissionDisable *EnableCode 39 BufferingDisable *Enable |
| Code 39 LengthPID : 00h 02hSize : 00h 02h (2 Bytes) | 1^st Byte- 01h~62h 2^nd Byte- 62h~01h | Minimum Length1~98 (Default: 1)Maximum Length98~1 (Default: 98) |
| Trioptic Code 39 ReadabilityPID : 00h 03hSize : 00h 01h (1 Byte) | - 00h- 01h | Disable *Enable |
| Code 39 Security LevelPID : 00h 04hSize : 00h 01h (1 Byte) | - 00h- 01h- 02h- 03h | Level 0Level 1Level 2 *Level 3 |
Parameter(s)
< Table 8-1-3 > Reply Symbology Parameter(s) Field (Continued)
| Parameter / PID / Size Options Descriptions | ||
| Codabar ReadabilityPID : 01h 00hSize : 00h 01h (1 Byte) | - 00h- 01h | DisableEnable * |
| Codabar SettingsPID : 01h 01hSize : 00h 04h (4 Bytes) | 1^st Byte- 00h- 01h- 02h- 03h 2^nd Byte- 00h- 01h- 02h- 03h- 04h 3^rd Byte- 00h- 01h 4^th Byte- 00h- 01h | Primary Format SelectionCodabar Standard format *Codabar ABC formatCodabar CLSI formatCodabar CX formatStart/ Stop Symbol TransmissionDisable *Enable ABCD/ABCDEnable abcd/abcdEnable ABCD/TN*EEnable abcd/tn*eCheck Digit VerificationDisable *EnableCheck Digit TransmissionDisable *Enable |
| Codabar LengthPID : 01h 02hSize : 00h 02h (2 Bytes) | 1^st Byte- 01h~62h 2^nd Byte- 62h~01h | Minimum Length1~98 (Default: 4)Maximum Length98~1 (Default: 98) |
| Codabar Check DigitPID : 01h 03hSize : 00h 01h (1 Byte) | - 00h- 01h- 02h- 03h- 04h- 05h- 06h | Modulus 16*Modulus 10/Weight 3Modulus 11Modulus 10/Weight 27 Check DRWeight Modulus 11Runes (Modulus 10/Weight 2) |
Parameter(s)
< Table 8-1-3 > Reply Symbology Parameter(s) Field (Continued)
| Parameter / PID / Size Options Descriptions | ||
| UPC-A/UPC-E ReadabilityPID: 02h 00hSize: 00h 02h (2 Bytes) | 1^st Byte- 00h- 01h 2^nd Byte- 00h- 01h | UPC-A ReadabilityDisableEnable *UPC-E ReadabilityDisableEnable * |
| UPC-A/UPC-E SettingPID: 02h 01hSize: 00h 06h (6 Bytes) | 1^st Byte- 00h- 01h 2^nd Byte- 00h- 01h 3^rd Byte- 00h- 01h 4^th Byte- 00h- 01h 5^th Byte- 00h- 01h 6^th Byte- 00h- 01h | UPC-E ExpansionDisable *EnableUPC StandardizationDisable *EnableUPC Numeric SystemDisableEnable *UPC-A Check Digit TransmissionDisableEnable *UPC-E Check Digit TransmissionDisableEnable *UPC "leading 1" PortionDisable *Enable |
| UPC-A/UPC-E SupplementPID: 02h 02hSize: 00h 03h (3 Bytes) | 1^st Byte- 00h- 01h- 02h- 03h 2^nd Byte- 00h- 01h 3^rd Byte- 00h- 01h | Supplement Digits SelectionWithout *With only 2 supplement digitsWith only 5 supplement digitsWith 2/5 supplement digitsForce Supplement Digits OutputDisable *EnableUPC Family Addenda SeparatorDisable *Enable |
Parameter(s)
< Table 8-1-3 > Reply Symbology Parameter(s) Field (Continued)
| Parameter / PID / Size Options Descriptions | ||
| EAN-13/EAN-8 ReadabilityPID: 03h 00hSize: 00h 02h (2 Bytes) | 1^st Byte- 00h- 01h 2^nd Byte- 00h- 01h | EAN/JAN-13 ReadabilityDisableEnable *EAN/JAN-8 ReadabilityDisableEnable * |
| EAN-13/EAN-8 SettingPID: 03h 01hSize: 00h 04h (4 Bytes) | 1^st Byte- 00h- 01h 2^nd Byte- 00h- 01h 3^rd Byte- 00h- 01h 4^th Byte- 00h- 01h | EAN-8 ExpansionDisable *EnableEAN-13 Check Digit TransmissionDisableEnable *EAN-8 Check Digit TransmissionDisableEnable *ISBN/ISSN Reading CheckDisable *Enable |
| EAN-13/EAN-8 SupplementPID: 03h 02hSize: 00h 03h (3 Bytes) | 1^st Byte- 00h- 01h- 02h- 03h 2^nd Byte- 00h- 01h 3^rd Byte- 00h- 01h | Supplement Digits SelectionWithout *With only 2 supplement digitsWith only 5 supplement digitsWith 2/5 supplement digitsForce Supplement Digits OutputDisable *EnableEAN Family Addenda SeparatorDisable *Enable |
| EAN Supplement ControlPID: 03h 04hSize: 00h 01h (1 Byte) | - 00h- 01h- 02h- 03h- 04h- 05h- 06h- 07h | Disable All Specific Prefix Supplement Output *Enable All Specific Prefix Supplement OutputEnable 491 Supplement OutputEnable 978/979 Supplement OutputEnable 977 Supplement OutputEnable 378/379 Supplement OutputEnable 414/419 Supplement OutputEnable 434/439 Supplement Output |
| UCC Coupon Extended Code ReadabilityPID: 03h 03hSize: 00h 01h (1 Byte) | - 00h- 01h | Disable*Enable |
Parameter(s)
< Table 8-1-3 > Reply Symbology Parameter(s) Field (Continued)
| Parameter / PID / Size Options Descriptions | ||
| IATA ReadabilityPID: 04h 00hSize: 00h 01h (1 Byte) | - 00h- 01h | Disable *Enable |
| IATA SettingPID: 04h 01hSize: 00h 04h (4 Bytes) | 1^st Byte- 00h- 01h 2^nd Byte- 00h- 01h- 02h- 03h- 04h 3^rd Byte- 00h- 01h 4^th Byte- 00h- 01h | IATA Checking Selection15-digit fixed length IATA checking*Variable length IATA checkingCheck Digit VerificationDisable *check digit automatic verificationS/N checking digit verification onlyCPN checking digit verification onlyCPN, Airline and S/N check digit verificationCheck Digit TransmissionDisable*EnableStart/Stop Symbol TransmissionDisable *Enable |
| Interleaved 2 of 5 ReadabilityPID: 04h 02hSize: 00h 01h (1 Byte) | - 00h- 01h | DisableEnable * |
| Interleaved 2 of 5 SettingsPID: 04h 03hSize: 00h 03h (3 Bytes) | 1^st Byte- 00h- 01h 2^nd Byte- 00h- 01h- 02h 3^rd Byte- 00h- 01h | Decoding Format SelectionInterleaved 2 of 5 *German Postal CodeUSS/OPCC Check Digit VerificationDisable *USS check digitOPCC check digitCheck Digit TransmissionDisable *Enable |
| Standard/Industrial 2 of 5 ReadabilityPID: 04h 04hSize: 00h 01h (1 Byte) | - 00h- 01h | Disable *Enable |
| Matrix 2 of 5 ReadabilityPID: 04h 05hSize: 00h 01h (1 Byte) | - 00h- 01h | Disable *Enable |
| China Postal Code ReadabilityPID: 04h 06hSize: 00h 01h (1 Byte) | - 00h- 01h | Disable *Enable |
Parameter(s)
< Table 8-1-3 > Reply Symbology Parameter(s) Field (To be continued)
| Parameter / PID / Size Options Descriptions | ||
| Code 25 SettingPID:04h 07hSize:00h 02h (2 Bytes) | 1^st Byte-00h-01h 2^nd Byte-00h-01h | Check Digit VerificationDisable *EnableCheck Digit TransmissionDisable *Enable |
| Code 25 LengthPID:04h 08hSize:00h 02h (2 Bytes) | 1^st Byte-01h~62h 2^nd Byte-62h~01h | Minimum Length1~98 (Default: 4)Maximum Length98~1 (Default: 98) |
| Code 11 ReadabilityPID:05h 00hSize:00h 01h (1 Byte) | -00h-01h | Disable *Enable |
| Code 11 SettingPID:05h 01hSize:00h 02h (2 Bytes) | 1^st Byte-00h-01h-02h 2^nd Byte-00h-01h | Check Digit VerificationDisable *1-check digit verification2-check digit verificationCheck Digit TransmissionDisable *Enable |
| Code 11 LengthPID:05h 02hSize:00h 02h (2 Bytes) | 1^st Byte-01h~62h 2^nd Byte-62h~01h | Minimum Length1~98 (Default: 4)Maximum Length98~1 (Default: 98) |
| Code 93 ReadabilityPID:06h 00hSize:00h 01h (1 Byte) | -00h-01h | DisableEnable * |
| Code 93 Check Digit TransmissionPID:06h 01hSize:00h 01h (1 Byte) | -00h-01h | Disable *Enable |
| Code 93 LengthPID:06h 02hSize:00h 02h (2 Bytes) | 1^st Byte-01h~62h 2^nd Byte-62h~01h | Minimum Length1~98 (Default: 1)Maximum Length98~1 (Default: 98) |
Parameter(s)
< Table 8-1-3 > Reply Symbology Parameter(s) Field (Continued)
| Parameter / PID / Size Options Descriptions | ||
| MSI/Plessey ReadabilityPID : 07h 00hSize : 00h 01h (1 Byte) | - 00h- 01h | Disable *Enable |
| MSI/Plessey SettingPID : 07h 01hSize : 00h 02h (2 Bytes) | 1^st Byte- 00h- 01h- 02h 2^nd Byte- 00h- 01h | Check Digit SelectionMOD 10 check digit *MOD 10-10 check digitMOD 11-10 check digitCheck Digit TransmissionDisable *Enable |
| MSI/Plessey LengthPID : 07h 02hSize : 00h 02h (2 Bytes) | 1^st Byte- 01h~62h 2^nd Byte- 62h~01h | Minimum Length1~98 (Default: 4)Maximum Length98~1 (Default: 98) |
| Code 128/EAN-128 ReadabilityPID : 08h 00hSize : 00h 01h (1 Byte) | - 00h- 01h | DisableEnable * |
| Code 128/EAN-128 SettingPID : 08h 01hSize : 00h 01 (1 Byte) | - 00h- 01h | ISBT Concatenation Off *ISBT Concatenation On |
| Code 128/EAN-128 LengthPID : 08h 02hSize : 00h 02h (2 Bytes) | 1^st Byte- 01h~62h 2^nd Byte- 62h~01h | Minimum Length1~98 (Default: 1)Maximum Length98~1 (Default: 98) |
| Code 128/EAN-128 Security LevelPID : 08h 03hSize : 00h 01h (1 Byte) | - 00h- 01h | Level 0Level 1 * |
| GS1-128 ReadabilityPID : 08h 04hSize : 00h 01h (1 Byte) | - 00h- 01h | DisableEnable * |
| GS1-128 LengthPID : 08h 05hSize : 00h 02h (2 Bytes) | 1^st Byte- 01h~62h 2^nd Byte- 62h~01h | Minimum Length1~98 (Default: 1)Maximum Length98~1 (Default: 98) |
Parameter(s)
< Table 8-1-3 > Reply Symbology Parameter(s) Field (Continued)
| Parameter / PID / Size Options Descriptions | ||
| UK/Plessey ReadabilityPID: 09h 00hSize: 00h 01h (1 Byte) | - 00h- 01h | Disable *Enable |
| UK/Plessey SettingPID: 09h 01hSize: 00h 03h (3 Bytes) | 1^st Byte- 00h- 01h 2^nd Byte- 00h- 01h 3^rd Byte- 00h- 01h | Primary Format SelectionStandard *CLSIConvert X to A-FDisable *EnableCheck Digit TransmissionDisable *Enable |
| UK/Plessey LengthPID: 09h 02hSize: 00h 02h (2 Bytes) | 1^st Byte- 01h~62h 2^nd Byte- 62h~01h | Minimum Length1~98 (Default: 4)Maximum Length98~1 (Default: 98) |
| Telepen ReadabilityPID: 0Ah 00hSize: 00h 01h (1 Byte) | - 00h- 01h | Disable *Enable |
| Telepen SettingPID: 0Ah 01hSize: 00h 02h (2 Bytes) | 1^st Byte- 00h- 01h 2^nd Byte- 00h- 01h | Primary Format SelectionTelepen Full ASCII modeTelepen Numeric mode *Check Digit TransmissionDisable *Enable |
| Telepen LengthPID: 0Ah 02hSize: 00h 02h (2 Bytes) | 1^st Byte- 01h~62h 2^nd Byte- 62h~01h | Minimum Length1~98 (Default: 4)Maximum Length98~1 (Default: 98) |
| GS 1 DataBar ReadabilityPID: 20h 00hSize: 00h 03h (3 Bytes) | 1^st Byte- 00h- 01h 2^nd Byte- 00h- 01h 3^rd Byte- 00h- 01h | GS1 DataBar (RSS-14)DisableEnable *GS1 DataBar LimitedDisableEnable *GS1 DataBar ExpandedDisableEnable * |
| GS 1 DataBar Expanded LengthPID: 20h 01hSize: 00h 02h (2 Bytes) | 1^st Byte- 01h~4Ah 2^nd Byte- 4Ah~01h | Minimum Length1~74 (Default: 4)Maximum Length74~1 (Default: 74) |
Parameter(s)
< Table 8-1-3 > Reply Symbology Parameter(s) Field (Continued)
| Parameter / PID / Size Options Descriptions | ||
| Composite Code ReadabilityPID : 21h 00hSize : 00h 01h (1 Byte) | - 00h- 01h | Disable *Enable |
| UPC Composite ModePID : 21h 01hSize : 00h 01h (1 Byte) | - 00h- 01h | Disable *Enable |
| PDF417/ Micro PDF417ReadabilityPID : 22h 00hSize : 00h 02h (2 Bytes) | 1^st Byte- 00h- 01h 2^nd Byte- 00h- 01h | PDF417 ReadabilityDisableEnable *Micro PDF417 ReadabilityDisable *Enable |
| Codablock F ReadabilityPID : 23h 00hSize : 00h 01h (1 Byte) | - 00h- 01h | Disable *Enable |
| Code 16K ReadabilityPID : 24h 00hSize : 00h 01h (1 Byte) | - 00h- 01h | Disable *Enable |
| Code 16K LengthPID : 24h 01hSize : 00h 02h (2 Bytes) | 1^st Byte- 01h~A0h 2^nd Byte- A0h~01h | Minimum Length1~160 (Default: 1)Maximum Length160~1 (Default: 160) |
| Code 49 ReadabilityPID : 25h 00hSize : 00h 01h (1 Byte) | - 00h- 01h | Disable *Enable |
| Code 49 LengthPID : 25h 01hSize : 00h 02h (2 Bytes) | 1^st Byte- 01h~51h 2^nd Byte- 51h~01h | Minimum Length1~81 (Default: 1)Maximum Length81~1 (Default: 81) |
Parameter(s)
< Table 8-1-3 > Reply Symbology Parameter(s) Field (Continued)
| Parameter / PID / Size Options Descriptions | ||
| QR Code ReadabilityPID : 30h 00hSize : 00h 01h (1 Byte) | - 00h- 01h | DisableEnable * |
| Micro QR Code ReadabilityPID : 30h 01hSize : 00h 01h (1 Byte) | - 00h- 01h | DisableEnable * |
| QR Code SettingPID : 30h 02hSize : 00h 02h (2 Bytes) | 1^st Byte- 00h- 01h 2^nd Byte- 00h- 01h- 02h | QR Code AppendDisableEnable *QR Code Inverse ReadingDisable *EnableAuto Detect |
| QR Code LengthPID : 30h 03hSize : 00h 04h (4 Bytes) | 1^st & 2^nd Byte- 01h~1BB1h 3^rd & 4^th Byte- 1BB1h~01h | Minimum Length(Big Endian)1~7089 (Default: 1)Maximum Length(Big Endian)7089~1 (Default: 7089) |
| Data Matrix ReadabilityPID : 31h 00hSize : 00h 01h (1 Byte) | - 00h- 01h | DisableEnable * |
| Data Matrix SettingPID : 31h 01hSize : 00h 02h (2 Bytes) | 1^st Byte- 00h- 01h 2^nd Byte- 00h- 01h- 02h | Data Matrix AppendDisableEnable *Data Matrix Inverse ReadingDisable *EnableAuto Detect |
| Data Matrix LengthPID : 31h 02hSize : 00h 04h (4 Bytes) | 1^st & 2^nd Byte- 01h~C2Ch 3^rd & 4^th Byte- C2Ch~01h | Minimum Length(Big Endian)1~3116 (Default: 1)Maximum Length(Big Endian)3116~1 (Default: 3116) |
| MaxiCode ReadabilityPID : 32h 00hSize : 00h 01h (1 Byte) | - 00h- 01h | Disable *Enable |
| MaxiCode LengthPID : 32h 01hSize : 00h 02h (2 Bytes) | 1^st Byte- 01h~96h 2^nd Byte- 96h~01h | Minimum Length1~150 (Default: 1)Maximum Length150~1 (Default: 150) |
Parameter(s)
< Table 8-1-3 > Reply Symbology Parameter(s) Field (Continued)
| Parameter / PID / Size Options Descriptions | ||
| Aztec ReadabilityPID : 33h 00hSize : 00h 01h (1 Byte) | - 00h- 01h | Disable *Enable |
| Aztec SettingPID : 33h 01hSize : 00h 02h (2 Bytes) | 1^st Byte- 00h- 01h 2^nd Byte- 00h- 01h- 02h | Aztec AppendDisable *EnableAztec Inverse ReadingDisable *EnableAuto Detect |
| Aztec LengthPID : 33h 02hSize : 00h 04h (4 Bytes) | 1^st & 2^nd Byte- 01h~EF8h 3^rd & 4^th Byte- EF8h~01h | Minimum Length(Big Endian)1~3832 (Default: 1)Maximum Length(Big Endian)3832 ~1 (Default: 3832) |
| Chinese Sensible ReadabilityPID : 34h 00hSize : 00h 01h (1 Byte) | - 00h- 01h | Disable *Enable |
| Chinese Sensible LengthPID : 34h 01hSize : 00h 04h (4 Bytes) | 1^st & 2^nd Byte- 01h~1E99h 3^rd & 4^th Byte- 1E99h~01h | Minimum Length(Big Endian)1~7833 (Default: 1)Maximum Length(Big Endian)7833~1 (Default: 7833) |
| Korea Post CodePID : 50h 00hSize : 00h 01h (1 Byte) | - 00h- 01h | Disable *Enable |
| Australian Post ReadabilityPID : 51h 00hSize : 00h 01h (1 Byte) | - 00h- 01h | Disable *Enable |
| Australian Post Output FormatPID : 51h 01hSize : 00h 03h (3 Bytes) | - 00h FFh FFh- 00h 00h 00h- 00h 7Fh FFh- 01h 00h FFh | Raw format Output *Numeric Encoding OutputAlphanumeric Encoding OutputAutodiscriminate Output |
| US Planet ReadabilityPID : 52h 00hSize : 00h 01h (1 Byte) | - 00h- 01h | Disable *Enable |
| US Planet Check DigitTransmissionPID : 52h 01hSize : 00h 01h (1 Byte) | - 00h- 01h | Disable *Enable |
Parameter(s)
< Table 8-1-3 > Reply Symbology Parameter(s) Field (Continued)
| Parameter / PID / Size Options Descriptions | ||
| US Postnet ReadabilityPID : 53h 00hSize : 00h 01h (1 Byte) | - 00h- 01h | Disable *Enable |
| US Postnet Check Digit TransmissionPID : 53h 01hSize : 00h 01h (1 Byte) | - 00h- 01h | Disable *Enable |
| British Post ReadabilityPID : 54h 00hSize : 00h 01h (1 Byte) | - 00h- 01h | Disable *Enable |
| British Post Check Digit TransmissionPID : 54h 01hSize : 00h 01h (1 Byte) | - 00h- 01h | Disable *Enable |
| Japan Post ReadabilityPID : 55h 00hSize : 00h 01h (1 Byte) | - 00h- 01h | Disable *Enable |
| Netherlands KIX Code ReadabilityPID : 56h 00hSize : 00h 01h (1 Byte) | - 00h- 01h | Disable *Enable |
| Intelligent Mail ReadabilityPID : 57h 00hSize : 00h 01h (1 Byte) | - 00h- 01h | Disable *Enable |
2.9 Device Info
Get Device Info (ALL)
Descriptions
Request the desired device information as well as DataWizard Premium information parameters
Packet Format
| Prefix | Opcode | Status | Length | Parameter(s) | LRC | Suffix | |||
| 7Eh | D6h | 00h 01h | 00h | Variable | See Below Variable | 7Eh | |||
| 1 Byte | 3 | Bytes | 1 Byte | 2 Bytes | Variable | 1 Byte | 1 Byte | ||
| Parameter(s) | |||||||||
| First Parameter | ...... | Last Parameter | |||||||
| PID Size | PID Size | ||||||||
| 2 Bytes | 2 Bytes | ...... | 2 Bytes | 2 Bytes | |||||
| See Next Page | |||||||||
. Host Requirements
If the device successfully received the above command issued by the host, the device will pack all requested parameters into a "Reply Device Info" message string then send to the host. Please refer to the "Reply Device Info" command for details. Otherwise, a "Device NAK" will be sent to host to indicate issue a command error. However, if the host can receive any response from the device within the user preset time-out duration, please resend the above command.
. Parameter(s) Field
Get Device Status can request multiple parameters at one time, so it takes compound parameters.
. Length
Total size (bytes) of the Parameter(s) field
.LRC
"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"
. Size
Total size (bytes) of the Options field
Parameter(s)
< Table 9-1-1 > Get Device Info Parameter(s) Field
| Parameter PID Size | ||
| Custom ID 00h 00h | 00h 00h | |
| Module No. 00h 01h | 00h 00h | |
| Hardware ID 00h 02h | 00h 00h | |
| Software ID 00h 03h | 00h 00h | |
| DataWizard Premium Info. 01h 00h | 00h 00h | |
| Total Count of Data Scripts 01h 01h | 00h 00h |
Reply Device Info (ALL)
Descriptions
Reply the desired device information as well as DataWizard Premium information parameters. Reply Device Status is sent by the device in response to the Get Device Info command. It sends the values for all the desired parameters requested in the Get Device Info command.
Packet Format
| Prefix | Opcode | Status | Length | Parameter(s) | LRC | Suffix | ||
| 7Eh | 17h | 00h 01h | 00h | Variable | See Below Variable | 7Eh | ||
| 1 Byte | 3 | Bytes | 1 Byte | 2 Bytes | Variable | 1 Byte | 1 Byte | |
. Host Requirements
Since Reply Device Info is a device-to-host message, there is no response for this message.
. Parameter(s) Field
Reply Device Info can change multiple parameters at one time, so it takes compound parameters.
. Length
Total size (bytes) of the Parameter(s) field
.LRC
"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"
. Size
Total size (bytes) of the Options field
Parameter(s)
< Table 9-1-2 > Reply Device Info Parameter(s) Field
| Parameter / PID / Size Options Descriptions | ||
| Custom IDPID : 00h 00hSize : 00h XXh (Variable Bytes) | - XXh...XXh XXh | (For example: CINO) |
| Module No.PID : 00h 01hSize : 00h XXh (Variable Bytes) | - XXh...XXh XXh | (For example: FUZZYSCAN F790WD) |
| Hardware IDPID : 00h 02hSize : 00h XXh (Variable Bytes) | - XXh...XXh XXh | (For example: OPIH3001M2400FR) |
| Software IDPID : 00h 03hSize : 00h XXh (Variable Bytes) | - XXh...XXh XXh | (For example: 1.03.01) |
| DataWizard Premium Info.PID : 01h 00hSize : 00h 0Fh | - XXh...XXh XXh | (For example: 0.9-1.0-0.90.01) |
| Total Count of Data ScriptsPID : 01h 01hSize : 00h 01h | - 00h- 01h- 02h- 03h- 04h- 05h- 06h- 07h- 08h- 09h- 0Ah- 0Bh- 0Ch- 0Dh- 0Eh- 0Fh- 10h | 012345678910111213141516 |
Get Record Count (WF)
Descriptions
Request the total record count of Batch Mode
Available for F & L series
Packet Format
| Prefix | Opcode | Status | Length | Parameter(s) | LRC | Suffix | ||
| 7Eh | D6h 00h 03h | 00h 00h 00h | <Null> | D5h | 7Eh | |||
| 1 Byte | 3 | Bytes | 1 Byte | 2 Bytes | 0 Byte | 1 Byte | 1 Byte | |
. Host Requirements
If the device successfully received the above command issued by the host, the device will pack all requested parameters into a "Reply Record Count" message string then send to the host. Please refer to the "Reply Record Count" command for details. Otherwise, a "Device NAK" will be sent to host to indicate issue a command error. However, if the host can receive any response from the device within the user preset time-out duration, please resend the above command.
. Parameter(s) Field
Get Device Status can request multiple parameters at one time, so it takes compound parameters.
. Length
Total size (bytes) of the Parameter(s) field
.LRC
"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"
. Size
Total size (bytes) of the Options field
Reply Record Count (WF)
Descriptions
Reply the total record count of Batch Mode
Available for F & L series
Packet Format
| Prefix | Opcode | Status | Length | Parameter(s) | LRC | Suffix | ||
| 7Eh | 17h | 00h 03h | 00h 00h 02h | See Notes | Variable | 7Eh | ||
| 1 Byte | 3 | Bytes | 1 Byte | 2 Bytes | 2 Bytes | 1 Byte | 1 Byte | |
. Host Requirements
Since Reply Device Info is a device-to-host message, there is no response for this message.
. Parameter(s) Field
Reply Device Info can change multiple parameters at one time, so it takes compound parameters.
. Length
Total size (bytes) of the Parameter(s) field
.LRC
"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"
. Size
Total size (bytes) of the Options field
.Notes
The two bytes record count is formatted as High Byte Low Byte. For example, number 60000 is described as EAh 60h.
2.10 Acknowledgement
Device ACK (ALL)
Descriptions
Device acknowledgement
Device ACK message is used to guarantee the reliability of packet transfers for commands that have no natural response, such as Action Commands, Set commands. Device ACK can not be disabled.
Packet Format
| Prefix | Opcode Status | Length | Parameter(s) | LRC Suffix | ||
| 7Eh | 0Fh 00h 00h | 00h 00h 00h | <Null> 0F | 7Eh | ||
| 1 Byte | 3 Bytes 1 Byte | 2 Bytes | 0 Byte 1 Byte | 1 Byte | ||
. Host Requirements
Since Device ACK is a device-to-host message, there is no response for this message.
. Parameter(s) Field
Device ACK message takes no parameters, so the Parameter(s) field is null.
. Length
Total size (bytes) of the Parameter(s) field
.LRC
"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"
Device NAK (ALL)
Descriptions
Device non-acknowledgement
Device NAK message is used to guarantee the reliability of packet transfers for commands that have no natural response, such as Action Commands, Set commands. On receiving a bad command, the scanner will send a Device NAK message to issue a command error including Opcode error, LRC check digit error and so on. Device NAK may not be disabled.
Packet Format
| Prefix | Opcode Status | Length | Parameter(s) | LRC Suffix | ||
| 7Eh | 0Eh 00h XXh | 00h 00h 00h | <Null> 0E | 7Eh | ||
| 1 Byte | 3 Bytes 1 Byte | 2 Bytes | 0 Byte | 1 Byte | 1 Byte | |
. Host Requirements
On receiving a bad command, it takes the device about 1 second to clear out the command buffer. So you are NOT supposed to send other commands during this period of time after receiving the Device NAK message. Since Device NAK is a device-to-host message, there is no response for this message.
. Opcode Field
The third byte of the Opcode varies according to the error code. It is reserved.
. Parameter(s) Field
Device NAK message takes no parameters, so the Parameter(s) field is null.
. Length
Total size (bytes) of the Parameter(s) field
.LRC
"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"
Host ACK (ALL)
Descriptions
Host acknowledgement in packet format.
Host ACK message is sent from host to device to guarantee the correctness of the decode data.
Packet Format
| Prefix | Opcode Status | Length | Parameter(s) | LRC Suffix | ||
| 7Eh | 91h 10h 00h | 00h 00h 04h | See below Variable | 7Eh | ||
| 1 Byte 3 | Bytes 1 Byte 2 Bytes | 4 Bytes 1 Byte 1 Byte | ||||
. Host Requirements
There is no response for this message.
. Length
Total size (bytes) of the Parameter(s) field
.LRC
"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"
Parameter(s)
< Table 10-1 > Host ACK Parameter(s) Field
| Parameter / PID / Size | Options | Descriptions |
| Host ACKPID :Size : 00h 04h (4 Bytes) | -XXh XXh...XXh | Indicates the Data Packet ID (See Decode Data in Chapter 2.2) to which the Host ACK is replied |
Host NAK (ALL)
Descriptions
Host non-acknowledgement
Host NAK message is sent from host to device to indicate that the data received is not correct.
Packet Format
| Prefix | Opcode Status | Length | Parameter(s) | LRC Suffix | ||
| 7Eh | 90h 10h 00h | 00h 00h 04h | See below Variable | 7Eh | ||
| 1 Byte 3 | Bytes 1 Byte 2 Bytes | 4 Bytes 1 Byte 1 Byte | ||||
. Host Requirements
There is no response for this message.
. Length
Total size (bytes) of the Parameter(s) field
.LRC
"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"
Parameter(s)
< Table 10-2 > Host NAK Parameter(s) Field
| Parameter / PID / Size Options | Descriptions |
| Host NAKPID :Size : 00h 04h (4 Bytes) | -XXh XXh...XXhIndicates the Data Packet ID (See Decode Data in Chapter 2.2) to which the Host NAK is replied |
Host ACK Extension (WF)
Descriptions
Host acknowledgement
Host ACK Extension is an extension of Host ACK which added a user defined message.
Available for F & L series
Packet Format
| Prefix | Opcode | Status | Length | Parameter(s) | LRC | Suffix | ||
| 7Eh | 91h | 10h 01h | 00h 02h | 00h | See Next Page | Variable | 7Eh | |
| 1 Byte | 3 | Bytes | 1 Byte | 2 Bytes | 512 Bytes | 1 Byte | 1 Byte | |
. Host Requirements
There is no response for this message.
. Length
Total size (bytes) of the Parameter(s) field
.LRC
"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"
Parameter(s)
| Size | Parameter Value | ||
| 4 Bytes | Data Packet ID | XXh XXh XXh XXh(See Notes) | |
| 2 Bytes | Code Page | XXh XXh (See Notes) | |
| 1 Byte | Bit 7 | Manual Close | -0 Disable-1 Enable |
| Bit 0~6 | Auto Close | -0h Disable-3h after 3 seconds-5h after 5 seconds-8h after 8 seconds-Ah after 10 seconds | |
| 1 Byte | Bit 7~6 | Left Align | Set Bit 7 to 1, Bit 6 to 0 |
| Right Align | Set Bit 7 to 0, Bit 6 to 1 | ||
| Center Align | Set both Bit 7 and Bit 6 to 1 or 0 | ||
| Bit 5~0 | Message Type | -0h Tips-1h Warning-2h Question-3h Information-4h Error-5h Lock | |
| 1 Byte | Bit 4~7 | Beeping Type | -0h Short-1h Long |
| Bit 0~3 | Number of Beep | -0h Disable-1h Once-2h 2 times-3h 3 times-5h 5 times-8h 8 times-Ah 10 times | |
| 1 Byte | Bit 4~7 | Vibration Duration | -1h 100ms-2h 200ms-3h 300ms-4h 400ms-5h 500ms |
| Bit 0~3 | Number of Vibration | -0h Disable-1h 1 time-2h 2 times-3h 3 times-4h 4 times-5h 5 times | |
| 3 Bytes | Message Length | XXh XXh XXh (See Notes) | |
| 499 Bytes | Message Content | XXh... (See Notes) | |
.Notes
- Data Packet ID: If The Transmission Format is set to "Packet Data" (SETUP->Online Scanning -> Online Options -> Transmission Format -> Packet Data), the first 4 bytes of the Decode Data (Chapter 2.2) Command's Parameter field indicates the Data Packet ID.
- The following Chart lists all available Code Pages and their 2-byte Hex value.
| 437 OEM - United States B5h 01h | ||
| 737 OEM - Greek (formerly 437G) E1h 02h | ||
| 850 OEM - Multilingual Latin I 52h 03h | ||
| 852 OEM - Latin II 54h 03h | ||
| 855 OEM - Cyrillic 57h 03h | ||
| 857 OEM - Turkish 59h 03h | ||
| 860 OEM - Portuguese 5Ch 03h | ||
| 863 OEM - French Canadian 5Fh 03h | ||
| 865 OEM - Nordic 61h 03h | ||
| 866 OEM - Russian | 62h 03h | |
| 932 ANSI/OEM Japanese (Shift-JIS) | A4h 03h | |
| 936 ANSI/OEM - Simplified Chinese (GB2312) | A8h 03h | |
| 950 ANSI/OEM - Traditional Chinese (Big5) | B6h 03h | |
| 1250 | ANSI - Central European | E2h 04h |
| 1251 | ANSI - Cyrillic | E3h 04h |
| 1252 | ANSI - Latin 1 | E4h 04h |
| 1253 | ANSI - Greek | E5h 04h |
| 1254 | ANSI - Turkish | E6h 04h |
| 1255 | ANSI - Hebrew | E7h 04h |
- Message Length has at most three bytes. If the first byte is 0xFF, the following two bytes represent the content length, formatted as High Byte Low Byte. Otherwise, the first byte represents the content length itself, and the following two bytes will become part of the message content.
- Message Content uses Little-endian UCS-2 character set. If shorter than 503 bytes, the rest bytes should be set to 00h.
Host NAK Extension (WF)
Descriptions
Host acknowledgement
Host NAK Extension is an extension of Host NAK which added a user defined message.
Available for F & L series
Packet Format
| Prefix | Opcode | Status | Length | Parameter(s) | LRC | Suffix | ||
| 7Eh | 90h | 10h 01h | 00h 02h 00h | See Next Page Variable | 7Eh | |||
| 1 Byte | 3 | Bytes | 1 Byte | 2 Bytes | 512 Bytes | 1 Byte | 1 Byte | |
. Host Requirements
There is no response for this message.
. Length
Total size (bytes) of the Parameter(s) field
.LRC
"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"
Parameter(s)
| Size | Parameter Value | ||
| 4 Bytes | Data Packet ID | XXh XXh XXh XXh(See Notes) | |
| 2 Bytes | Code Page | XXh XXh (See Notes) | |
| 1 Byte | Bit 7 | Manual Close | -0 Disable-1 Enable |
| Bit 0~6 | Auto Close | -0h Disable-3h after 3 seconds-5h after 5 seconds-8h after 8 seconds-Ah after 10 seconds | |
| 1 Byte | Bit 7~6 | Left Align | Set Bit 7 to 1, Bit 6 to 0 |
| Right Align | Set Bit 7 to 0, Bit 6 to 1 | ||
| Center Align | Set both Bit 7 and Bit 6 to 1 or 0 | ||
| Bit 5~0 | Message Type | -0h Tips-1h Warning-2h Question-3h Information-4h Error-5h Lock | |
| 1 Byte | Bit 4~7 | Beeping Type | -0h Short-1h Long |
| Bit 0~3 | Number of Beep | -0h Disable-1h Once-2h 2 times-3h 3 times-5h 5 times-8h 8 times-Ah 10 times | |
| 1 Byte | Bit 4~7 | Vibration Duration | -1h 100ms-2h 200ms-3h 300ms-4h 400ms-5h 500ms |
| Bit 0~3 | Number of Vibration | -0h Disable-1h 1 time-2h 2 times-3h 3 times-4h 4 times-5h 5 times | |
| 3 Bytes | Message Length | XXh XXh XXh (See Notes) | |
| 499 Bytes | Message Content | XXh... (See Notes) | |
.Notes
- Data Packet ID: If The Transmission Format is set to "Packet Data" (SETUP->Online Scanning -> Online Options -> Transmission Format -> Packet Data), the first 4 bytes of the Decode Data (Chapter 2.2) Command's Parameter field indicates the Data Packet ID.
- The following Chart lists all available Code Pages and their 2-byte Hex value.
| 437 OEM - United States B5h 01h | ||
| 737 OEM - Greek (formerly 437G) E1h 02h | ||
| 850 OEM - Multilingual Latin I 52h 03h | ||
| 852 OEM - Latin II 54h 03h | ||
| 855 OEM - Cyrillic 57h 03h | ||
| 857 OEM - Turkish 59h 03h | ||
| 860 OEM - Portuguese 5Ch 03h | ||
| 863 OEM - French Canadian 5Fh 03h | ||
| 865 OEM - Nordic 61h 03h | ||
| 866 OEM - Russian | 62h | 03h |
| 932 ANSI/OEM Japanese (Shift-JIS) | A4h | 03h |
| 936 ANSI/OEM - Simplified Chinese (GB2312) | A8h | 03h |
| 950 ANSI/OEM - Traditional Chinese (Big5) | B6h | 03h |
| 1250 | ANSI - Central European | E2h 04h |
| 1251 | ANSI - Cyrillic | E3h 04h |
| 1252 | ANSI - Latin 1 | E4h 04h |
| 1253 | ANSI - Greek | E5h 04h |
| 1254 | ANSI - Turkish | E6h 04h |
| 1255 | ANSI - Hebrew | E7h 04h |
- Message Length has at most three bytes. If the first byte is 0xFF, the following two bytes represent the content length, formatted as High Byte Low Byte. Otherwise, the first byte represents the content length itself, and the following two bytes will become part of the message content.
- Message Content uses Little-endian UCS-2 character set. If shorter than 503 bytes, the rest bytes should be set to 00h.
Chapter 3 Customer Support
If you have any problem with your equipment, please contact Cino for technical support. Contact information is available at Cino website: www.cino.com.tw. If you purchased your product from a Cino business partner, please contact that business partner for support.
When you contact Cino for technical support, please provide following information:
- Serial number of the unit
- Model number
- System Information
www.cino.com.tw
FuzzyScan Serial Command Manual
CINO GROUP
PC WORTH INT'L CO., LTD.