Cino

F680 - Barcode Reader Cino - Free user manual and instructions

Find the device manual for free F680 Cino in PDF.

📄 251 pages English EN Download 💬 AI Question 10 questions ⚙️ Specs
Notice Cino F680 - page 1
Pick your language and provide your email: we'll send you a specifically translated version.
Product Type Handheld Barcode Reader (Barcode Scanner)
Model Cino F680
Dimensions (approx.) 170 x 70 x 100 mm (typical handheld)
Weight (approx.) 200 g (typical with cable)
Power Supply 5V DC via USB or RS232 (cable supplied)
Interfaces USB Virtual COM, RS232, Bluetooth (BT models), Wi-Fi (WF models)
Supported Symbologies 1D: Code 128, UPC/EAN, Code 39, Interleaved 2 of 5, etc.; 2D: QR Code, Data Matrix, MaxiCode, Aztec, PDF417, etc.
Scan Engine Area imager (2D) with aiming pattern
Operating Modes Trigger, Presentation, Force, Level, Alternative, Flash, Toggle, Diagnostic
LED Indicators Red, Green, Blue (programmable via serial command)
Beeper Programmable tones (beep sequence up to 64 nodes)
Image Capture Supported (A series): BMP, JPG, PNG, 8 or 32 bit
Bluetooth (on BT models) Classic Bluetooth, up to 7 scanners per cradle (PICO mode)
Wi-Fi (on WF models) 802.11 b/g/n, remote control and batch mode
Data Editing DataWizard Premium (Data Script, Security Script)
Maintenance and Cleaning Clean optics with soft, dry cloth; avoid solvents; store at 0–40°C, 5–95% RH
Safety Laser Class 2 (typical); comply with local regulations
Spare Parts and Reparability Contact Cino or authorized service for replacement cables, optics, housings
General Information Cino FuzzyScan series; manual covers serial commands; software configurable; firmware upgradeable

Frequently Asked Questions - F680 Cino

What barcodes can the Cino F680 read?
The F680 reads most 1D and 2D barcodes including Code 128, UPC/EAN, QR Code, Data Matrix, PDF417, and postal codes (USPS, Australia Post, etc.).
How do I change the operating mode of the scanner?
Use serial commands: for tethered models send TS Operation Mode (opcode 80h 08h 00h) with parameter 00h (trigger), 01h (force), 02h (presentation), etc. For Bluetooth models use BT Operation Mode.
Can I capture images with the F680?
Yes, models with Image Capture (A series) support capturing BMP, JPG, or PNG images. Use serial commands Enter Capture Image Mode, Get Capture Image Data, etc.
How do I connect the scanner via Bluetooth?
For Bluetooth versions, pair with a SmartCradle or PC. Use serial commands Get/Reply Connected MAC, Select By MAC to communicate. Ensure the Bluetooth Device Name is set via Set Bluetooth command.
What should I do if the scanner is not reading barcodes?
First, check the lens for dirt. Clean with a soft, dry cloth. Ensure the barcode is not damaged and is in the correct orientation. Try resetting to factory defaults using Factory Default command (80h 04h 00h).
How do I program the scanner without a manual?
The F680 is programmed via serial commands or configuration barcodes. The FuzzyScan Serial Command Manual provides full command reference. You can also download configuration software from Cino's website.
What is the default baud rate?
Default baud rate is 9600 bps with 8 data bits, no parity, 1 stop bit. Can be changed via Set USB COM or Set RS232 commands.
Does the F680 support Wi-Fi?
Yes, Wi-Fi models (WF series) support 802.11 b/g/n. They can be controlled remotely via Remote Indication, Remote Message, and batch mode. Use Set Wi-Fi command to configure.
How do I update the firmware?
Firmware updates are done via the Remote Programming command (enter/exit programming mode) or using Cino's DataWizard Premium software. Contact support for the latest firmware file.
What does the Device NAK mean?
Device NAK is an error response indicating a bad command (e.g., wrong opcode, incorrect LRC, or invalid parameter). Check the command packet format and retry after clearing the buffer (wait ~1 second).

User questions about F680 Cino

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Barcode Reader in PDF format for free! Find your manual F680 - Cino and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. F680 by Cino.

USER MANUAL F680 Cino

International Edition Rev.A5

Revision History

Rev. 01 April 1, 2013❖ Merged all the CMD Manuals of different series into one Manual❖ Added command TS A Operation Mode❖ Flash, Force, Toggle, and Diagnostic Mode in TS Operation Mode are available for L series from now on.❖ Change the parameter name of “Inverse Reading” to “1D Barcode Inverse Reading” inOperation❖ Added LED Illumination, Illumination Delay Duration inOperation.❖ Added Parameters forTS Operationincluding Operation Mode (Tethered A Series), Hand-Held Mode Illumination & Aiming Control, Hand-Free Mode Decode Aiming Control, Aiming Control, Delay Aiming Timeout, Presentation Background, Center Alignment, Mobile Phone Capture, Unique Barcode Reporting.❖ Modified parameter Code 128 Settings inSymbology❖ Added parameters forSymbology, including GS1-128, code 16k, code 49, QR code, Data Matrix, Maxicode, Aztec, Chinese Sensible, Australian post, US Planet, US Postnet, British post, Japan post, Netherlands KIX code, Intelligent mail.
Rev. 02 August 16, 2013❖ Added parameters forTransmission, including Data Script Active Setting, Data Script Setting, Security Script Setting and Data Wizard Premium Error Message.❖ AddedSecurity Check
Rev. 03 March 25, 2014❖ Added commandBT A Operation Mode❖ Added commandFS A Operation Mode❖ Added Auto Power Off Timeout and Bluetooth Device Name (Bluetooth A Series) inBluetooth❖ Added parameters forFS Operationand BT Operation, including Operation Mode (FA470 & SM5700 Series), Operation Mode (Bluetooth A Series), Hand-Held Mode Illumination & Aiming Control, Hand-Free Mode Decode Aiming Control, Aiming Control, Delay Aiming Timeout, Presentation Background Lighting, Center Alignment and Mobile Phone Capture.
Rev. 04 April 25, 2014❖ Page 2-17: Modified “LED Status” parameter inAction
Rev. 05 June 3, 2014❖ Page 1-4: ModifiedStatusdescription inCommand Structure

© Copyright Cino Group

© Copyright PC Worth Int'l Co., Ltd

Cino makes no warranty of any kind with regard to this publication, including, but not limited to, the implied warranty of merchantability and fitness for any particular purpose. Cino shall not be liable for errors contained herein or for incidental consequential damages in connection with the furnishing, performance, or use of this publication. This publication contains proprietary information that is protected by copyright. All rights are reserved. No part of this publication may be photocopied, reproduced or translated into any language, in any forms, in an electronic retrieval system or otherwise, without prior written permission of Cino. All product information and specifications shown in this document may be changed without prior notice.

Warranty

Cino warrants its products against defects in workmanship and materials from the date of shipment, provided that the product is operated under normal and proper conditions. The warranty provisions and durations are furnished by different warranty programs. The above warranty does not apply to any product which has been (i) misused; (ii) damaged by accident or negligence; (iii) modified or altered by the purchaser or other party; (iv) repaired or tampered by unauthorized representatives; (v) operated or stored beyond the specified operational and environmental parameters; (vi) applied software, accessories or parts are not supplied by Cino; (vii) damaged by circumstances out of Cino's control, such as, but not limited to, lightning or fluctuation in electrical power. Any defective product must follow the warranty program and RMA procedures to return Cino for inspection.

Table of Contents

About This Guide

Introduction

Chapter Descriptions

Notational Conventions

Related Documents

Command Overview 1-1

Command Briefing 1-2

Command Structure.... 1-4

Command Descriptions 2-1

Communication

Get Connected MAC, Reply Connected MAC (BT).... 2-2

Get Paired MAC, Reply Paired MAC(BT).... 2-4

Select By MAC, Deselect By MAC(BT).... 2-6

Select By ID, Deselect By ID(BT).... 2-8

Data

Decode Data (ALL).... 2-10

Transmit Record (ALL).... 2-11

Image

Enter Capture Image Mode (TS).... 2-12

Exit Capture Image Mode (TS).... 2-13

Capture Image Ready Notify (TS).... 2-14

Get Capture Image Data (TS).... 2-15

Action

LED Indicator (BT, TS).... 2-17

Beeping (ALL).... 2-18

Serial Trigger (ALL).... 2-19

Store Configuration (ALL) 2-20

Factory Default (ALL).... 2-21

Master Default (ALL).... 2-22

Security Check (ALL).... 2-23

BT Operation Mode (BT).... 2-24

BT A Operation Mode (BT).... 2-25

BT Synchronization (BT).... 2-26

FS Test Mode (FS).... 2-27

FS Operation Mode (FS).... 2-28

FS A Operation Mode (FS).... 2-29

SE Operation Mode (SE).... 2-30

TS Operation Mode (TS).... 2-31

TS A Operation Mode (TS).... 2-32

Paging (WF).... 2-33

Remote Indication (WF) 2-34

Remote Message (WF).... 2-36

Remote Clear (WF).... 2-38

Remote Lock (WF).... 2-40

Remote Unlock (WF).... 2-43

Remote Programming (WF).... 2-44

Remote Programming Extension (WF).... 2-45

Sync Date Time (WF).... 2-48

Delete Record (WF).... 2-49

Send Stern Data (WF).... 2-50

Interface

Corded Series

Set USB COM, Get USB COM, Reply USB COM (TS, SE, FM).... 2-51

Set RS232, Get RS232, Reply RS232 (TS, SE, FM).... 2-57

BT Scanner Series

Set USB COM, Get USB COM, Reply USB COM (BT).... 2-63

Set RS232, Get RS232, Reply RS232 (BT).... 2-69

Set Bluetooth, Get Bluetooth, Reply Bluetooth (BT) 2-75

Wi-Fi Scanner Series

Set USB HID, Get USB HID, Reply USB HID (WF).... 2-83

Set USB COM, Get USB COM, Reply USB COM (WF).... 2-89

Set Wi-Fi, Get Wi-Fi, Reply Wi-Fi (WF).... 2-95

Operation

Tether Scanner Series

Set TS Operation, Get TS Operation, Reply TS Operation (TS).... 2-101

Scan Engine Series

Set SE Operation, Get SE Operation, Reply SE Operation (SE)...... 2-115

Fixed-mount Scanner Series

Set FS Operation, Get FS Operation, Reply FS Operation (FS)...... 2-125

Bluetooth Scanner Series

Set BT Operation, Get BT Operation, Reply BT Operation (BT)...... 2-137

WiFi Scanner Series

Set WF Operation, Get WF Operation, Reply WF Operation (WF)...... 2-151

Set WF System, Get WF System, Reply WF System (WF).... 2-159

Set WF Scanning, Get WF Scanning, Reply WF Scanning (WF)...... 2-165

Transmission

Set Transmission, Get Transmission, Reply Transmission (ALL).... 2-173

Set Transmission, Get Transmission, Reply Transmission (WF)...... 2-181

Symbology

Set Symbology, Get Symbology, Reply Symbology (ALL).... 2-189

Device Info

Get Device Info, Reply Device Info (ALL).... 2-219

Get Record Count, Reply Record Count (ALL).... 2-223

Acknowledgement

Device ACK, Device NAK (ALL) 2-225

Host ACK, Host NAK (WF) 2-227

Host ACK Extension, Host NAK Extention (WF).... 2-229

Customer Support.... 3-1

About This Guide

Introduction

This guide provides complete programming information about the serial command of Cino FuzzyScan Scanner & OEM Engine, which enable Scanner to communicate with a serial host through a virtual COM port created.

Chapter Descriptions

Topics covered in this guide as follows:

Chapter 1 Command Overview

This chapter provides an overview of FuzzyScan Serial Command, including the command list, packet format and communication descriptions, etc.

Chapter2 Serial Command Descriptions

This chapter provides the detailed information of each serial command.

Notational Conventions

The following conventions are used in this document:

ALL: All FuzzyScan Series Scanners

SE: FuzzyScan Scan Engines

TS: FuzzyScan Tethered Scanners

FS: FuzzyScan Fixed-mount Scanners & Scan Module

BT: FuzzyScan Bluetooth Scanners

WF: FuzzyScan Wi-Fi Scanners

You may refer to following related documents to get more information:

■ FuzzyScan Scanner Integration Guide
■ FuzzyScan Scanner Programming Manual
■ FuzzyScan Scanner API Manual

If you need more information, please contact your supplier or visit our web site www.cino.com.tw.

Chapter 1 Command Overview

This chapter provides a comprehensive view of the FuzzyScan Serial Command, including:

  • Command Briefing
  • Command Structure

This will help programmer to understand the command structure and each key elements of FuzzyScan Serial Commands.

1.1 Command Briefing

The FuzzyScan Serial Commands provide a simple and effective way for serial host application to communicate with FuzzyScan device with ease. All commands have been categorized into several functional groups, including “Communication”, “Data”, “Image”, “Action”, “Interface”, “Operation”, “Transmission”, “Symbology”, “Device Info” and “Acknowledgement”. The following table shows all available commands for scanner.

In Action Group, there are ten special commands (Available for Wi-Fi L & F Series) which are used to remote control the scanner to display a user defined message, to beep, to vibrate, etc. Remote Control commands include Paging, Remote Indication, Remote Message, Remote Clear, Remote Lock, Remote Unlock, Remote Programming and Remote Programming Extension.

Important: For better use of Wi-Fi L & F Series Scanner, we introduced the concept of Programming Mode, which refers to an occasion where scanner is permitted to perform all the commands. However, Remote Control listed above is permitted on any occasion, which means scanner can only perform Remote Control when it is not in Programming mode. So if you want to set or get parameters to or from the scanner, you need to put it into Programming Mode using Remote Programming (Enter) or Remote Programming Extension (Enter) command. If not, the scanner will reject all the commands (except Remote Control) and replies a Device NAK. Once entered the Programming Mode, a lock message will be shown on the screen and the subsequent programming commands will all take effect. After the operation, you need to send Remote Programming (Exit) or Remote Programming Extension (Exit) to exit the mode.

Functional GroupCommand Name Supported ScannerMessage Source
CommunicationGet/Reply Connected MAC Bluetooth Scanners Host/Device
Get/Reply Paired MAC Bluetooth Scanners Host/Device
Select/Deselect By MAC Bluetooth Scanners Host/Host
Select/Deselect By ID Bluetooth Scanners Host/Host
DataDecode Data All Series Scanners Host
Transmit Record Wi-Fi Scanners Host
ImageEnter Capture Image Mode Tethered ScannersHost
Exit Capture Image ModeTethered ScannersHost
Capture Image Ready NotifyTethered ScannersHost
Get Capture Image Data Tethered Scanners Host
ActionLED Indicator Bluetooth, TetheredScannersHost
Beeping All Series Scanners Host
Serial Trigger All Series ScannersHost
Store Configuration All Series Scanners Host
Factory Default All Series Scanners Host
Master Default All Series Scanners Host
Security Check All Series Scanners Host
BT Operation Mode Bluetooth Scanners Host
BT Synchronize Bluetooth Scanners Host
FS Test Mode Fixed-mount Scanners Host
FS Operation ModeFixed-mount ScannersHost
SE Operation ModeScan EnginesHost
TS Operation ModeTethered ScannersHost
TS A Operation ModeTethered ScannersHost
PagingWi-Fi ScannersHost
Remote IndicationWi-Fi ScannersHost
Remote MessageWi-Fi ScannersHost
Remote Clear Wi-Fi ScannersHost
Remote LockWi-Fi ScannersHost
Remote UnlockWi-Fi ScannersHost
Remote ProgrammingWi-Fi ScannersHost
Remote Programming ExtensionWi-Fi ScannersHost
Sync Date Time Wi-Fi ScannersHost
Delete RecordWi-Fi ScannersHost
InterfaceSet/ Get/ Reply USB COMHost/Host/Device
Set/ Get/ Reply RS232Host/Host/Device
Set/ Get/ Reply USB HIDHost/Host/Device
Set/ Get/ Reply BluetoothBluetooth ScannersHost/Host/Device
Set/ Get/ Reply Wi-FiWi-Fi ScannersHost/Host/Device
OperationSet/ Get/ Reply TS OperationTethered ScannersHost/Host/Device
Set/ Get/ Reply SE OperationScan EnginesHost/Host/Device
Set/ Get/ Reply FS OperationFixed-mount ScannersHost/Host/Device
Set/ Get/ Reply BT OperationBluetooth ScannersHost/Host/Device
Set/ Get/ Reply WF Operation Wi-Fi Scanners Host/Host/Device
Set/ Get/ Reply WF SystemWi-Fi ScannersHost/Host/Device
Set/ Get/ Reply WF ScanningWi-Fi ScannersHost/Host/Device
TransmissionSet/ Get/ Reply TransmissionAll Series ScannersHost/Host/Device
Set/ Get/ Reply TransmissionWi-Fi ScannersHost/Host/Device
SymbologySet/ Get/ Reply SymbologyAll Series ScannersHost/Host/Device
Device InfoGet/ Reply Device InfoWi-Fi ScannersHost/Device
Get/ Reply Record CountAll Series ScannersHost/Device
Functional GroupCommand Name SupportedScanner Message Source
AcknowledgementDevice ACKAll Series ScannersDevice
Device NAKAll Series ScannersDevice
Host ACKAll Series ScannersHost
Host NAKAll Series ScannersHost
Host ACK ExtensionWi-Fi ScannersHost
Host ACK ExtensionWi-Fi ScannersHost

1.2 Command Structure

Packet Format

The following table shows the general packet format of FuzzyScan Serial Command.

PrefixOpcodeStatusLengthParameter(s)Check DigitSuffix
1 Byte3Bytes1 Byte2 BytesVariable1 Byte LRC or 2 Bytes CRC16
Field Name Size Descriptions
Prefix1 Byte Fixed, “7Eh”
Opcode3 BytesOperation code to identifies each command
Status1 ByteBit 2 ACK/NAK0 = Request1 = Do not requestBit 4 Check Digit0 = LRC (1 Byte)1 = CRC16 (2 Bytes) (See Notes)Bit 5 Continuation0 = Last packet1 = Intermediate packetOther BitsReserved. (Always 0)
Length2 BytesTotal bytes amount of the Parameter(s) fieldFormatted as High Byte Low Byte.Length = Low Byte + High Byte x 256If Parameter(s) = null, Length = 00h, 00h.
Parameter(s)VariableSee next paragraph
Check Digit1 ByteLRC: “Opcode” XOR “Status” XOR “Length” XOR “Parameter(s)”
2 BytesCRC16: From “Opcode” to “Parameter(s)” (See Notes)
Suffix1 Byte Fixed, “7Eh”

.Notes

CRC16 Check Digit is only used in image command which is sent from scanner to host.

Command Overview

All FuzzyScan Serial Commands begin and end with the fixed prefix and suffix - 7Eh, which serve as parentheses. Between the prefix and the suffix is the command body. The main body consists of Opcode, Status, Length, Parameter(s) and check digit.

According to the functional group, there are two different parameter formats. The “Action” and “Acknowledgement” command groups use the “Simple” parameter format. The other command groups allow the “Compound” parameters to make more effective control. Please refer to the following paragraphs for details.

Escape Sequence

Several characters have special functions in FuzzyScan Serial Command and communication manipulation, such as "Prefix (7Eh)", "Suffix (7Eh)", "ACK (06h)", "NAK (15h)", "XON (11h)", "XOFF (13h)" and "Backslash (5Ch). If you have to use above characters in your command string (from "Length", "Parameter" to "LRC"), please replace them with their escaped value listed in following table.

ASCII ~ \ACK NAKXON XOFF
Hex7Eh5Ch06h15h11h
Escaped Value5Ch 00h5Ch 01h5Ch 02h5Ch 03h5Ch 04h

For example,

If a host-to-device serial command is listed as below:

The "06h" have to be replaced "5Ch 02h". So the correct command string will be,

In other words, if the device send following string to host.

Your serial host application have to change "5Ch 02h" to "06h" as well.

Parameter Format

Generally, there are two different parameter formats, "Command with Simple Parameter(s)" and "Command with Compound Parameters".

Commands with simple parameters

The Action, Acknowledgement, Data and Image commands belong to this group.

1) Action

The parameter filed of Action commands can be "Null" or several option bytes. The following table shows the structure of Parameter(s) field:

Parameter(s)
First byte of the parameter......Last byte of the parameter
Options ......Options

If the device successfully received the action command issued by the host, a "Device ACK" will be sent to the host right after the device performed the action. Otherwise, a "Device NAK" will be sent to host to issue a command error

If the host can't receive any reaction within the user preset time-out duration, this can be considered as a transmission failure. In this case, you are recommended to check the cable connection, power supply, setting of communication profile, and so on.

2) Acknowledgement command

There are four Acknowledge commands including “Device ACK”, “Device NAK”, “Host ACK” and “Host NAK”. All Acknowledgement commands have no parameters, it means the parameter field of those commands has to be set to “null”.

3) Data

The Decode Data is a special command, and it has to be considered as an unconditional event. If the "Data Transmission Packet" parameter is set to "Enable", the scanner will send a Packed Decode Data Message rather than a Raw Data message to the host after a successful decode. The actual decoded data will be put into the Parameter(s) field of Decode Data message string. Differently, the Transmit Record command is used to retrieve records from the scanner. Scanner send back the stored records as reply.

4) Image

Image commands is used to capture image, which is available for A series scanner. Enter/Exit Capture Image Mode formatted like Action command, scanner replies ACK/NAK. Capture Image Ready Notify is similar to Decode Data which is sent from the scanner to the host. And the format of Get Capture Image Data is like Transmit Record command, which is used to retrieve data from the scanner.

Commands with compound parameters

The Communication, Interface, Operation, Transmission, Symbology and Device Info commands belong to this group. For better understanding of the command format, we divide these commands into three types: Set, Get and Reply

1) Set

Set commands are used to configure the device setting. The parameter field can handle multiple parameters request at same time. It means you are able to change multiple setting of device at same as well. It is very useful for programmer to make fast initialization on the device.

Each parameter is composed of "PID", "Size" and "Option". If necessary, you are able to pack the selected parameters into one parameter field in accordance with the format described in the following table.

Parameter(s)
First Parameter ...Last Parameter
PID Size Option...PID Size Option
2 Bytes2 ByteVariable...2 Bytes2 ByteVariable
Size Descriptions
PID2 Byte Parameter ID
Size2 Bytes Total bytes of the “Option” sectionFormatted as High Byte Low Byte.Length = Low Byte + High Byte x 256If Parameter(s) = null, Length = 00h, 00h.Operation code to identifies each command
OptionsVariable Parameter setting

Upon the receipt of a Set command, the scanner will response a Device ACK or Device NAK message to indicate whether the new settings has been performed successfully or not. If the host did not receive any response from the device within the user preset time-out duration, please resend the command.

2) Get

Get commands are used to obtain the device setting. The parameter field can handle multiple parameters request at the same time. It means you are able to obtain multiple settings of device at same as well. It is a very useful for application to reduce communication overhead.

Each parameter is composed of "PID", "Size" and "Option". If necessary, you are able to pack the selected parameters into one parameter field in accordance with the format described in the following table. Due to Get command does not have Option section, please always set the "Size" section to "00h 00h".

Parameter(s)
First Parameter...Last Parameter
PID Size ...PID Size
2 Bytes2 Byte2Bytes2 Byte

If the device received a Get command issued by the host successfully, the device will pack all requested parameters into one Reply message string and send it to the host. Otherwise, a Device NAK will be sent to host to indicate a command error. However, if the host didn't receive any response from the device within the user preset time-out duration, please resend the above command.

3) Reply

Reply message is sent by the device in response to the Get command. All the desired values are listed one by one in the Parameter(s) field in accordance with the format described in the following table. Each parameter is composed of "PID", "Size" and "Option". If necessary, you are able to pack the selected parameters into one parameter field in accordance with the format described in the following table. Please note that the Parameter(s) field of a Reply message is the same as Set command.

Parameter(s) (Reply)
First Parameter...Last Parameter
PID SizeOption...PID SizeOption
2 Bytes2 ByteVariable...2 Bytes2 ByteVariable

Since Reply message is a device-to-host return message, there is no response for this message.

Chapter 2 Command Descriptions

2.1 Communication

Get Connected MAC (BT)

Descriptions

Get the connected scanners' MAC addresses

This command is used when working with the SmartCradle in PICO mode.

Available for F, L & A series

Packet Format

PrefixOpcodeStatusLengthPID SizeLRC Suffix
7EhD6hFFhFFh00h 00h04hFFh 00h00h 00h2Dh 7Eh
1 Byte3 Bytes1 Byte2 Bytes2 Bytes2 Bytes1 Byte 1 Byte

. Host Requirements

If the device successfully received the above command issued by the host, a "Device ACK" will send to the host right after the device performed the action. Otherwise, a "Device NAK" will be sent to host to issue a command error. However, if the host can not receive any response from the device within the user preset time-out duration, please resend the above command.

. Length

Total size (bytes) of the Parameter(s) field

.LRC

"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"

. Size

Total size (bytes) of the Options field

Reply Connected MAC (BT)

Descriptions

List all the connected scanners' MAC addresses

Reply Connected MAC is sent by the device in response to the Get Connected MAC command.

Available for F, L & A series

Packet Format

PrefixOpcodeStatusLengthParameterLRCSuffix
7Eh17h00h00h Variable(MAC List)Variable7Eh
1 Byte3Bytes1 Byte2 BytesVariable1 Byte1 Byte

. Host Requirements

If the device successfully received the above command issued by the host, a "Device ACK" will send to the host right after the device performed the action. Otherwise, a "Device NAK" will be sent to host to issue a command error. However, if the host can not receive any response from the device within the user preset time-out duration, please resend the above command.

. Length

Total size (bytes) of the Parameter(s) field

.LRC

"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"

. Size

Total size (bytes) of the Options field

Command Descriptions

Get Paired MAC (BT)

Descriptions

Get all the paired scanners' MAC addresses

This command is used when the working with the SmartCradle in PICO mode.

Available for F, L & A series

Packet Format

PrefixOpcodeStatusLengthPIDSizeLRCSuffix
7EhD6hFFhFFh00h00h04hFFh 02h00h 00h2Fh 7Eh
1 Byte3Bytes1 Byte2 Bytes2 Bytes2 Bytes1 Byte 1 Byte

. Host Requirements

If the device successfully received the above command issued by the host, a "Device ACK" will send to the host right after the device performed the action. Otherwise, a "Device NAK" will be sent to host to issue a command error. However, if the host can not receive any response from the device within the user preset time-out duration, please resend the above command.

. Length

Total size (bytes) of the Parameter(s) field

.LRC

"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"

. Size

Total size (bytes) of the Options field

Reply Paired MAC (BT)

Descriptions

List all the paired scanners' MAC addresses

Reply Paired MAC is sent by the device in response to the Get Paired MAC command.

Available for F, L & A series

Packet Format

PrefixOpcodeStatusLengthParameterLRCSuffix
7Eh17h00h00h Variable(MAC List)Variable7Eh
1 Byte3Bytes1 Byte2 Bytes42 Bytes1 Byte1 Byte

. Host Requirements

If the device successfully received the above command issued by the host, a "Device ACK" will send to the host right after the device performed the action. Otherwise, a "Device NAK" will be sent to host to issue a command error. However, if the host can not receive any response from the device within the user preset time-out duration, please resend the above command.

. Parameter(s) Field

Since up to 7 scanners can be connected to one smart cradle concurrently, the Parameter field of the Reply Paired MAC takes 42 bytes. If there are less than 7 scanners paired, the rest bytes of the parameter field is filled with FFh.

. Length

Total size (bytes) of the Parameter(s) field

.LRC

"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"

. Size

Total size (bytes) of the Options field

Select By MAC (BT)

Descriptions

Use the MAC address to select the desired scanner to communicate

This command is useful when multiple scanners are connected to the SmartCradle in PICO mode. Select By MAC is often preceded by a Get Connected MAC command to provide a list from which the desired scanner will be selected. Afterwards, all the subsequent serial command will be send to this selected scanner, and the other scanners will not be able to communicate with the host until a Deselect By MAC command is sent.

Available for F, L & A series

Packet Format

PrefixOpcodeStatusLengthParameterLRCSuffix
7Eh95hFFhFFh00h 00h0AhSee Below Variable7Eh
1 Byte3Bytes1 Byte2 Bytes10 Bytes1 Byte1 Byte
Parameter
First and the only Parameter
PID SizeOptions
FFh 00h00h 06h(Scanner's MAC Address)
2 Bytes2 Bytes6 Bytes

. Host Requirements

If the device successfully received the above command issued by the host, a "Device ACK" will send to the host right after the device performed the action. Otherwise, a "Device NAK" will be sent to host to issue a command error. However, if the host can not receive any response from the device within the user preset time-out duration, please resend the above command.

. Length

Total size (bytes) of the Parameter(s) field

.LRC

"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"

. Size

Total size (bytes) of the Options field

Deselect By MAC (BT)

Descriptions

Deselect the scanner by MAC

This command is used to deselect the scanner which is selected by command Select By MAC. Please note that once this command is processed successfully, the host will be able to receive the decode data from all the connected scanners, but the subsequent serial commands sent will be neglected because there are not any selected scanner which is available to receive commands. Available for F, L & A series

Packet Format

PrefixOpcodeStatusLengthParameterLRCSuffix
7Eh95hFFhFFh00h 00h0AhSee Below 66h7Eh
1 Byte3Bytes1 Byte2 Bytes10 Bytes1 Byte1 Byte

. Host Requirements

If the device successfully received the above command issued by the host, a "Device ACK" will send to the host right after the device performed the action. Otherwise, a "Device NAK" will be sent to host to issue a command error. However, if the host can not receive any response from the device within the user preset time-out duration, please resend the above command.

. Length

Total size (bytes) of the Parameter(s) field

.LRC

"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"

. Size

Total size (bytes) of the Options field

Select By ID (BT)

Descriptions

Use the auto-assigned ID number to select the desired scanner to communicate

This command is useful when multiple scanners are connected to the SmartCradle in PICO mode. Afterwards, all the subsequent serial command will be send to this selected scanner, and the other scanners will not be able to communicate with the host until a Deselect By ID command is sent. Available for F, L & A series

Packet Format

PrefixOpcodeStatusLengthParameterLRCSuffix
7Eh95hFFhFFh00h 00h05hSee Below Variable7Eh
1 Byte3Bytes1 Byte2 Bytes5 Bytes1 Byte1 Byte
Parameter
First and the only Parameter
PID SizeOptions
FFh 01h00h 01h(Scanner's ID)
2 Bytes2Bytes1 Byte

. Host Requirements

If the device successfully received the above command issued by the host, a "Device ACK" will send to the host right after the device performed the action. Otherwise, a "Device NAK" will be sent to host to issue a command error. However, if the host can not receive any response from the device within the user preset time-out duration, please resend the above command.

. Length

Total size (bytes) of the Parameter(s) field

.LRC

"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"

. Size

Total size (bytes) of the Options field

Deselect By ID (BT)

Descriptions

Deselect the scanner by ID

This command is used to deselect the scanner which is selected by command Select By ID. Please note that once this command is processed successfully, the host will be able to receive the decode data from all the connected scanners, but the subsequent serial commands sent will be neglected because there are not any selected scanner which is available to receive commands. Available for F, L & A series

Packet Format

PrefixOpcodeStatusLengthParameterLRCSuffix
7Eh95hFFhFFh00h 00h05hSee Below6Fh7Eh
1 Byte3Bytes1 Byte2 Bytes5 Bytes1 Byte1 Byte
Parameter
First and the only Parameter
PIDSizeOptions
FFh 01h00h 01h00h
2 Bytes2 Bytes1 Byte

. Host Requirements

If the device successfully received the above command issued by the host, a "Device ACK" will send to the host right after the device performed the action. Otherwise, a "Device NAK" will be sent to host to issue a command error. However, if the host can not receive any response from the device within the user preset time-out duration, please resend the above command.

. Length

Total size (bytes) of the Parameter(s) field

.LRC

"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"

. Size

Total size (bytes) of the Options field

2.2 Data

Decode Data (ALL)

Descriptions

Decoded Data in FSC packet format

Decode Data is considered as an unexpected event since the decoded data will be sent to the host whenever the scanner scanned a barcode, either accidentally or intentionally. The decoded data is sent in two types of format, either packed or unpacked. If packed data is selected, the scanner will send a packed Decode Data message rather than a Raw Data message to the host after a successful decode.

Packet Format

PrefixOpcode StatusLengthParameter(s)LRC Suffix
7Eh14h 00h 00h00h VariableVariable Variable7Eh
1 Byte3 Bytes 1 Byte2 BytesVariable 1 Byte1 Byte

. Host Requirements

Since Decode Data is a device-to-host message, there is no response for this message.

. Parameter(s) Field

The first 4 bytes indicates the Data Packet ID.

. Length

Total size (bytes) of the Parameter(s) field

.LRC

"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"

Transmit Record (WF)

Descriptions

Transmit all record(s) of Batch Mode

Available for F & L series

Packet Format

PrefixOpcode StatusLengthParameter(s)LRC Suffix
7Eh80h 11h 01h00h 00h 00h<Null> 90h 7Eh
1 Byte3 Bytes 1 Byte 2 Bytes0 Byte 1 Byte 1 Byte

. Host Requirements

If the device successfully received the above command issued by the host, the device will reply the "Transmission Start Command" followed by the raw record data and the data transmission will end with the "Transmission End Command". Please refer to the following table for details. Otherwise, a "Device NAK" will be sent to host to indicate a command error. However, if the host can receive any response from the device within the user preset time-out duration, please resend the above command.

. Parameter(s) Field

Get Device Status can request multiple parameters at one time, so it takes compound parameters.

.LRC

"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"

. Size

Total size (bytes) of the Options field

Reply Format

● Part 1 – Transmission Start Command

PrefixOpcode StatusLengthParameter(s)LRC Suffix
7Eh01h 02h 00h00h 00h 00h<Null> 03h 7Eh
1 Byte 3Bytes 1 Byte 2 Bytes0 Byte 1 Byte 1 Byte

- Part 2 – Raw Data

● Part 3 – Transmission End Command

PrefixOpcode StatusLengthParameter(s)LRC Suffix
7Eh01h 02h 01h00h 00h 00h<Null> 02h 7Eh
1 Byte 3Bytes 1 Byte 2 Bytes0 Byte 1 Byte1 Byte

2.3 Image

Enter Capture Image Mode (TS)

Descriptions

Enter Capture Image Mode

Once scanner is entered the Capture Image Mode, you can trigger the scanner to capture image repeatedly, after every image is captured and ready to be retrieved, scanner will send out a Capture Image Ready Notify packet to host, and then the host can send Get Capture Image Data command to retrieve the image data.

Available for A series

Packet Format

PrefixOpcodeStatusLengthParameter(s)LRCSuffix
7Eh80h1Ah 00h00h 00h0AhSee below Variable7Eh
1 Byte3Bytes1 Byte2 Bytes10 Bytes1 Byte1 Byte

. Host Requirements

If the device successfully received the above command issued by the host, a "Device ACK" will be sent to the host right after the device performed the action. Otherwise, a "Device NAK" will be sent to host to issue a command error. However, if the host can not receive any response from the device within the user preset time-out duration, please resend the above command.

.LRC

"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"

Parameter(s)

SizeParameterDescriptions
1 ByteType- 00h Photo- 01h Video
1 ByteFormat- 00h 8 bits BMP- 01h 32 bits BMP- 02h JPG- 03h PNG
1 ByteAimer- 00h Without Aimer- 01h With Aimer
1 ByteAE- 00h Fixed Exposure- 01h Auto Exposure
2 Bytes (Big Endian)Exp Level(The higher value the longer exposure time will be used)- 0001h Level 1- 0002h Level 2- ......(Range from Level 1 ~ 24)- 0018h Level 24
4 BytesTimeoutReserved (Always 00h)

Exit Capture Image Mode (TS)

Descriptions

Exit Capture Image Mode

Available for A series

Packet Format

PrefixOpcode StatusLengthParameter(s)LRC Suffix
7Eh80h 1Ah 01h00h 00h 00h<NULL> 9B7Eh
1 Byte 3Bytes 1 Byte 2 Bytes0 Byte 1 Byte1 Byte

. Host Requirements

If the device successfully received the above command issued by the host, a "Device ACK" will be sent to the host right after the device performed the action. Otherwise, a "Device NAK" will be sent to host to issue a command error. However, if the host can not receive any response from the device within the user preset time-out duration, please resend the above command.

. Length

Total size (bytes) of the Parameter(s) field

.LRC

"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"

Capture Image Ready Notify (TS)

Descriptions

Capture image ready notify.

When an image is captured by scanner and ready to be retrieved by host, this command will be sent as a notification.

Available for A series

Packet Format

PrefixOpcode StatusLengthParameter(s)LRC Suffix
7Eh0Fh 1Ah 00h00h 00h 00h157Eh
1 Byte3 Bytes 1 Byte2 Bytes0 Byte 1 Byte1 Byte

. Host Requirements

Since Capture Image Ready Notify is a device-to-host message, there is no response for this message.

. Parameter(s) Field

Capture Image Ready Notify takes no parameters, so the Parameter(s) field is null.

. Length

Total size (bytes) of the Parameter(s) field

.LRC

"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"

Get Capture Image Data (TS)

Descriptions

Get the captured image data.

When in Capture Image mode, scanner stores the image of the last trigger automatically. This command is used to get the latest image data. On receiving this command, scanner will pack all the image data into several command packets and send back to the host (See Next Page).

Available for A series

Packet Format

PrefixOpcode StatusLengthParameter(s)LRC Suffix
7Eh80h 1Ah 02h00h 00h 00h<Null> 987Eh
1 Byte3 Bytes 1 Byte2 Bytes0 Byte 1 Byte1 Byte

. Host Requirements

If the device successfully received the above command issued by the host, the device will send an "Image Data Output" to the host. Please refer to the "Image Data Output" command for details. Otherwise, a "Device NAK" will be sent to host to indicate issue a command error. However, if the host can not receive any response from the device within the user preset time-out duration, please resend the above command.

. Length

Total size (bytes) of the Parameter(s) field

.LRC

"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"

. Size

Total size (bytes) of the Options field

Reply Format

● Part 1 – First Image Data Command

PrefixOpcode StatusLength ParameterCRC16Suffix
7Eh0Fh 1Ah 02h34h 10h00hSee Below Variable7Eh
1 Byte 3Bytes 1 Byte 2Bytes 4096Bytes 2 Bytes1 Byte

● Part 2 – Subsequent Image Data Commands

PrefixOpcode StatusLength ParameterCRC16Suffix
7Eh0Fh 1Ah 02h34h 10h00hVariable7Eh
1 Byte 3Bytes 1 Byte 2Bytes 4096Bytes 2 Bytes1 Byte

● Part 3 – Last Image Data Command

PrefixOpcodeStatusLengthParameterCRC16Suffix
7Eh0Fh 1Ah 02h14h See NoteVariable7Eh
1 Byte3 Bytes1 Byte2 BytesMaximum 4096 Bytes2 Bytes1 Byte

.Notes

  1. Status is defined as follows:
ValueBit 2 ACK/NAKBit 4 Check DigitBit 5 ContinuationOther Bits
0 Do not requestLRC (1 Byte)Last packetReserved
1RequestCRC16 (2 Bytes)Intermediate packetAlways 0
  1. Length of the Last Image Data Command equals to the length of the remaining Image Data which should be no more than 4096 bytes.
  2. CRC16 Check Digit is calculated from the beginning of the Opcode field to the end of the Parameter field.

2.4 Action

LED Indicator (BT, TS)

Descriptions

Controls the LED indicators

This command turns on/off or restores one of the three LEDs, Red LED, Green LED, and Blue LED. Please note that LED Indicators can not be set to the default value by Factory Default or Master Default.

Available for Bluetooth F, L & A series and Tethered F, L & A series

Packet Format

PrefixOpcode StatusLengthParameter(s)LRC Suffix
7Eh80h 00h 00h00h 00h 02hSeeVariable7Eh
1 Byte3 Bytes 1 Byte 2 Bytes1 Byte1 Byte 1Byte

. Host Requirements

If the device successfully received the above command issued by the host, a "Device ACK" will be sent to the host right after the device performed the action. Otherwise, a "Device NAK" will be sent to host to issue a command error. However, if the host can not receive any response from the device within the user preset time-out duration, please resend the above command.

. Length

Total size (bytes) of the Parameter(s) field

.LRC

"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"

Parameter(s)

< Table 1-0 > LED Indicator Parameter(s) Field

Parameter / PID / SizeOptionsDescriptions
LED IndicatorPID :Size : 00h 02h (2 Bytes) 1^st Byte- 01h- 02h- 03h 2^nd Byte- 00h- 01h- 02hLED SelectionRed LEDGreen LEDBlue LEDLED StatusOFFONRestore to system control

Beeping (ALL)

Descriptions

User programmable beeping control

Once received the Beeping command, the device will follow the desired beep sequence to sound the beeper.

Packet Format

PrefixOpcode StatusLengthParameter(s)LRC Suffix
7Eh80h 01h 00h00h 00h 40hSeeVariable7Eh
1 Byte3 Bytes 1 Byte 2 Bytes64 Bytes 1 Byte1 Byte

. Host Requirements

If the device successfully received the above command issued by the host, a "Device ACK" will be sent to the host right after the device performed the action. Otherwise, a "Device NAK" will be sent to host to issue a command error. However, if the host can not receive any response from the device within the user preset time-out duration, please resend the above command.

. Length

Total size (bytes) of the Parameter(s) field

.LRC

"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"

Parameter(s)
< Table 1-1 > Beeping Parameter(s) Field

Parameter / PID / SizeOptionsDescriptions
BeepingPID :Size : 00h 40h (64 Bytes) 1^st 64^th ByteValue range:- 00h01h02h03h04h05h06h07h08h09h0Ah0Bh0Ch0Dh0Eh0Fh10hFFhThe 64-bytes parameter items specify 64 nodes respectively.The bigger the value, the lower it beeps.Duration of every node is fixed.10h serves as Suspension Node.The beep sequence is temporarily suspended when comes up against a Suspension Node.FFh serves as Termination Node.A beep sequence must end up with the Termination node FFh, otherwise a Device NAK will be sent to the host.The beep nodes following the termination node are indispensable but not part of the beep sequence.

Serial Trigger (ALL)

Descriptions

Start or Stop a scan session

When triggered on, the scanner attempts to obtain the requested data. When triggered off, the scanner aborts a decode attempt.

Packet Format

PrefixOpcode StatusLengthParameter(s)LRC Suffix
7Eh80h 02h 00h00h 00h 01hSeeVariable7Eh
1 Byte3 Bytes 1 Byte 2 Bytes1 Byte 1 Byte1 Byte

. Host Requirements

If the device successfully received the above command issued by the host, a "Device ACK" will be sent to the host right after the device performed the action. Otherwise, a "Device NAK" will be sent to host to issue a command error. However, if the host can not receive any response from the device within the user preset time-out duration, please resend the above command.

. Length

Total size (bytes) of the Parameter(s) field

.LRC

"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"

Parameter(s)

< Table 1-2 > Serial Trigger Parameter(s) Field

Parameter / PID / SizeOptionsDescriptions
Serial TriggerPID :- 00hOFFSize : 00h 01h (1 Byte) - 01hON

Store Configuration (ALL)

Descriptions

Save current settings into flash memory permanently

Note that this command is not available for storing the following settings: the beep sequence set by Beeping command; trigger status set by Serial Trigger command and LED status set by Indicator command.

Packet Format

PrefixOpcode StatusLengthParameter(s)LRC Suffix
7Eh80h 03h 00h00h 00h 00h83h7Eh
1 Byte3 Bytes 1 Byte2 Bytes0 Byte 1 Byte1 Byte

. Host Requirements

If the device successfully received the above command issued by the host, a "Device ACK" will be sent to the host right after the device performed the action. Otherwise, a "Device NAK" will be sent to host to issue a command error. However, if the host can not receive any response from the device within the user preset time-out duration, please resend the above command.

. Parameter(s) Field

Store Configuration command takes no parameters, so the Parameter(s) field is null.

. Length

Total size (bytes) of the Parameter(s) field

.LRC

"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"

Factory Default (ALL)

Descriptions

Set all parameters to the factory default

After sending this command, all parameters will be set to factory default value. Then the scanner resets all parameters into factory default values.

For Bluetooth L & F Series:

The radio link will be disconnected and the scanner will revert to uninstall state.

For Wi-Fi L & F Series:

Set all parameters to the factory default, except Fonts and Language Pack.

The radio link will be disconnected because Wi-Fi profiles are removed.

Packet Format

PrefixOpcode StatusLengthParameter(s)LRC Suffix
7Eh80h 04h 00h00h 00h 00h<Null> 84h7Eh
1 Byte3 Bytes 1 Byte2 Bytes0 Byte 1 Byte1 Byte

. Host Requirements

Upon receiving this command, the device sends a "Device ACK" message immediately to the host before performs the action. Then it takes about 500 milliseconds to complete all jobs to reset all parameters into factory default values. Please note that you are not supposed to send any command during this period of time.

However, a “Device NAK” message is passed to the host to issue a command error. If the host can not receive any response from the device within the user preset time-out duration, please resend the above command.

. Parameter(s) Field

Factory Default command takes no parameters, so the Parameter(s) field is null.

. Length

Total size (bytes) of the Parameter(s) field

.LRC

"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"

Master Default (ALL)

Descriptions

Set all parameters to the factory default except for the interface settings

The host interface related parameters still remain the same after performing the Master Default command.

For Bluetooth L & F Series:

Set all parameters to the factory default settings except for the following parameters:

Handshaking Protocol, Baud Rate, Data Frame, Serial Response Timeout, Bluetooth Device Name, Bluetooth PIN Code, Out-of-range Scanning, Interface Delay Settings.

And the radio link is still on.

For Wi-Fi L & F Series:

Restore Scanner Settings and keep Fonts, Language Pack, Batch Records, Wi-Fi Profile, System Settings, Interface Settings, Online Scanning and Batch Scanning Settings.

And the radio link is still on.

Packet Format

PrefixOpcode StatusLengthParameter(s)LRC Suffix
7Eh80h 04h 01h00h 00h 00h85h7Eh
1 Byte3 Bytes 1 Byte2 Bytes0 Byte 1 Byte1 Byte

. Host Requirements

If the device successfully received the above command issued by the host, a "Device ACK" will be sent to the host right after the device performed the action. Otherwise, a "Device NAK" will be sent to host to issue a command error. However, if the host can not receive any response from the device within the user preset time-out duration, please resend the above command.

. Parameter(s) Field

Master Default command takes no parameters, so the Parameter(s) field is null.

. Length

Total size (bytes) of the Parameter(s) field

.LRC

"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"

Security Check (ALL)

Descriptions

Host sends this command to verify the connected scanner.

Once the scanner receives this command, it will pass the 16-byte parameter data to the Security Script to generate a 16-byte result data and send it back as a reply command to the host. If the Security Script is disabled, the reply would be a Device NAK.

This command is only available for Scanners that support DataWizard Premium. For more details about DataWizard Premium, please refer to FuzzyScan DataWizard Premium User Manual.

Packet Format

PrefixOpcode StatusLengthParameter(s)LRC Suffix
7Eh80h 2Fh 00h00h 00h 10hVariable Variable7Eh
1 Byte3 Bytes 1 Byte 2 Bytes16 Bytes 1 Byte 1 Byte

. Host Requirements

If the security script does not exist or enabled, a "Device NAK" will be sent to the host. Otherwise, scanner will send back a Reply Command carrying the 16-byte result data (See Below). The host will check whether the result is right.

. Length

Total size (bytes) of the Parameter(s) field

.LRC

"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"

Reply Format

PrefixOpcode StatusLengthParameter(s)LRC Suffix
7Eh0Fh 2Fh 00h00h 00h 10hVariable Variable7Eh
1 Byte3 Bytes 1 Byte 2 Bytes16 Bytes 1 Byte 1 Byte

BT Operation Mode (BT)

Descriptions

Select operation mode for Bluetooth Scanner

BT Operation Mode is equivalent to the Operation Mode Selection in the Set BT Operation command. It is of more convenience to use BT Operation Mode of the Action Command Category. Available for F & L series

Packet Format

PrefixOpcode StatusLengthParameter(s)LRC Suffix
7Eh80h 08h 02h00h 00h 01hSee Below Variable7Eh
1 Byte3 Bytes 1 Byte 2 Bytes1 Byte 1 Byte1 Byte

. Host Requirements

If the device successfully received the above command issued by the host, a "Device ACK" will be sent to the host right after the device performed the action. Otherwise, a "Device NAK" will be sent to host to issue a command error. However, if the host can not receive any response from the device within the user preset time-out duration, please resend the above command.

. Length

Total size (bytes) of the Parameter(s) field

.LRC

"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"

Parameter(s)

< Table 4-1 > BT Operation Mode Parameter(s) Field

Parameter / PID / SizeOptionsDescriptions
BT Operation Mode
PID :- 00hTrigger mode (External triggering) *
Size : 00h 01h (1 Byte)- 02hPresentation mode (Auto Detection)

BT A Operation Mode (BT)

Descriptions

Select operation mode for Bluetooth Scanner

BT A Operation Mode is equivalent to the Operation Mode Selection in the Set BT Operation command. It is of more convenience to use BT A Operation Mode of the Action Command Category. Available for A series

Packet Format

PrefixOpcode StatusLengthParameter(s)LRC Suffix
7Eh80h 08h 05h00h 00h 03hSee Below Variable7Eh
1 Byte3 Bytes 1 Byte 2 Bytes3 Bytes 1 Byte 1 Byte

. Host Requirements

If the device successfully received the above command issued by the host, a "Device ACK" will be sent to the host right after the device performed the action. Otherwise, a "Device NAK" will be sent to host to issue a command error. However, if the host can not receive any response from the device within the user preset time-out duration, please resend the above command.

. Length

Total size (bytes) of the Parameter(s) field

.LRC

"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"

Parameter(s)

< Table 4-6 > BT A Operation Mode Parameter(s) Field

Parameter / PID / SizeOptionsDescriptions
BT A Operation ModePID :Size : 00h 03h (3 Byte)- 00h 01h 01h- 02h 01h 01hTrigger mode *Presentation mode

BT Synchronize (BT)

Descriptions

Synchronize BT scanner with SmartCradle

If the BT scanner(s) are working with the SmartCradle in PAIR mode or PICO mode, this command is used to sync the Scanner with the SmartCradle, so that the changes of the following six parameters will take effect instantly: "Handshaking Protocol", "Baud Rate", "Data Frame", "Serial Response Timeout", "Dollar Sign Control", "Field Delimiter" and "Data Transmission Packet". If not, the settings of the parameters described above will probably be neglected.

Note that if you are using the USB Virtual COM Port to connect the SmartCradle to the host, please close the virtual COM Port within 500 milliseconds right after you issue this command. Otherwise, the host can not identically detect the occupied COM Port after the synchronization.

Available for F, L & A series

Packet Format

PrefixOpcode StatusLengthParameter(s)LRC Suffix
7Eh80h 09h 00h00h 00h 00h<Null> 89h7Eh
1 Byte3 Bytes 1 Byte2 Bytes0 Byte 1 Byte1 Byte

. Host Requirements

If the device successfully received the above command issued by the host, a "Device ACK" will be sent to the host right after the device performed the action. Otherwise, a "Device NAK" will be sent to host to issue a command error. However, if the host can not receive any response from the device within the user preset time-out duration, please resend the above command.

. Parameter(s) Field

BT Synchronize command takes no parameters, so the Parameter(s) field is null.

. Length

Total size (bytes) of the Parameter(s) field

.LRC

"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"

FS Test Mode (FS)

Descriptions

Set the Fixed Mount and Scan Module to Test Mode.

You may refer to "FuzzyScan Fixed Mount Scanner Programming Manual" or "FuzzyScan Fixed Mount Scanner Quick Start Guide" for more details about the Test Mode.

Available for FM480, FA470, SM380 & SM5700 series

Packet Format

PrefixOpcode StatusLengthParameter(s)LRC Suffix
7Eh80h 06h 00h00h 00h 01hSee Below Variable7Eh
1 Byte3 Bytes 1 Byte 2 Bytes1 Byte 1 Byte1 Byte

. Host Requirements

If the device successfully received the above command issued by the host, a "Device ACK" will be sent to the host right after the device performed the action. Otherwise, a "Device NAK" will be sent to host to issue a command error. However, if the host can not receive any response from the device within the user preset time-out duration, please resend the above command.

. Length

Total size (bytes) of the Parameter(s) field

.LRC

"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"

Parameter(s)

< Table 4-2 > FS Test Mode Parameter(s) Field

Parameter / PID / SizeOptionsDescriptions
FS Test Mode
PID :- 00hFixed Reader Enter Test Mode 0
Size : 00h 01h (1 Byte)- 01hFixed Reader Enter Test Mode 1

FS Operation Mode (FS)

Descriptions

Select operation mode for Fixed Mount and Scan Module

FS Operation Mode is equivalent to the Operation Mode Selection in the Set FS Operation command. It is of more convenience to use FS Operation Mode of the Action Command Category. Available for FM480 & SM380 series

Packet Format

PrefixOpcode StatusLengthParameter(s)LRC Suffix
7Eh80h 08h 03h00h 00h 01hSee Below Variable7Eh
1 Byte3 Bytes 1 Byte 2 Bytes1 Byte 1 Byte1 Byte

. Host Requirements

If the device successfully received the above command issued by the host, a "Device ACK" will be sent to the host right after the device performed the action. Otherwise, a "Device NAK" will be sent to host to issue a command error. However, if the host can not receive any response from the device within the user preset time-out duration, please resend the above command.

. Length

Total size (bytes) of the Parameter(s) field

.LRC

"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"

Parameter(s)

< Table 4-3 > FS Operation Mode Parameter(s) Field

Parameter / PID / SizeOptionsDescriptions
FS Operation Mode
PID :- 00hTrigger mode (External triggering) *
Size : 00h 01h (1 Byte)- 01hForce mode (Continued power on)
- 02hPresentation mode (Auto Detection)
- 04hLevel mode (Auto power off)
- 06hAlternative mode (Periodic power off)

FS A Operation Mode (FS)

Descriptions

Select operation mode for Fixed Mount and Scan Module

FS A Operation Mode is equivalent to the Operation Mode Selection in the Set FS Operation command. It is of more convenience to use FS A Operation Mode of the Action Command Category. Available for FA470 & SM5700 series

Packet Format

PrefixOpcode StatusLengthParameter(s)LRC Suffix
7Eh80h 08h 05h00h 00h 03hSee Below Variable7Eh
1 Byte3 Bytes 1 Byte 2 Bytes3 Bytes 1 Byte 1 Byte

. Host Requirements

If the device successfully received the above command issued by the host, a "Device ACK" will be sent to the host right after the device performed the action. Otherwise, a "Device NAK" will be sent to host to issue a command error. However, if the host can not receive any response from the device within the user preset time-out duration, please resend the above command.

. Length

Total size (bytes) of the Parameter(s) field

.LRC

"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"

Parameter(s)

< Table 4-3 > FS A Operation Mode Parameter(s) Field

Parameter / PID / SizeOptionsDescriptions
FS A Operation ModePID :Size : 00h 03h (3 Byte)- 00h 01h 01h- 01h 01h 01h- 02h 01h 01h- 04h 01h 00h- 06h 01h 00hTrigger mode *Force modePresentation modeLevel modeAlternative mode

SE Operation Mode (SE)

Descriptions

Select operation mode for Scan Engine

SE Operation Mode is equivalent to the Operation Mode Selection in the Set SE Operation command. It is of more convenience to use SE Operation Mode of the Action Command Category. Available for SE380, SE390 & SE480 series

Packet Format

PrefixOpcode StatusLengthParameter(s)LRC Suffix
7Eh80h 08h 04h00h 00h 01hSee Below Variable7Eh
1 Byte3 Bytes 1 Byte 2 Bytes1 Byte 1 Byte1 Byte

. Host Requirements

If the device successfully received the above command issued by the host, a "Device ACK" will be sent to the host right after the device performed the action. Otherwise, a "Device NAK" will be sent to host to issue a command error. However, if the host can not receive any response from the device within the user preset time-out duration, please resend the above command.

. Length

Total size (bytes) of the Parameter(s) field

.LRC

"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"

Parameter(s)

< Table 4-4 > SE Operation Mode Parameter(s) Field

Parameter / PID / SizeOptionsDescriptions
SE Operation Mode
PID :- 00hTrigger mode (External triggering) *
- 01hForce mode (Continued power on) (See Note)
Size : 00h 01h (1 Byte)- 02hPresentation mode (Auto Detection)
- 04hLevel mode (Auto power off)
- 06hAlternative mode (Periodic power off)
- 09hLow Power mode (Low Power triggering)

.Notes

Force mode is not available for SE390 and SE480 series.

TS Operation Mode (TS)

Descriptions

Select operation mode for Tethered Scanner

TS Operation Mode is equivalent to the Operation Mode Selection in the Set TS Operation command. It is of more convenience to use TS Operation Mode of the Action Command Category. Available for F & L series

Packet Format

PrefixOpcode StatusLengthParameter(s)LRC Suffix
7Eh80h 08h 00h00h 00h 01hSee Below Variable7Eh
1 Byte3 Bytes 1 Byte 2 Bytes1 Byte 1 Byte1 Byte

. Host Requirements

If the device successfully received the above command issued by the host, a "Device ACK" will be sent to the host right after the device performed the action. Otherwise, a "Device NAK" will be sent to host to issue a command error. However, if the host can not receive any response from the device within the user preset time-out duration, please resend the above command.

. Length

Total size (bytes) of the Parameter(s) field

.LRC

"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"

Parameter(s)

< Table 4-5 > TS Operation Mode Parameter(s) Field

Parameter / PID / SizeOptionsDescriptions
TS Operation Mode
PID :- 00hTrigger mode (External triggering) *
Size : 00h 01h (1 Byte)- 01hForce mode (Continued power on)
- 02hPresentation mode (Auto detection)
- 04hLevel mode (Auto power off)
- 05hDiagnostic mode (Test reading)
- 06hAlternative mode (Periodic power off)
- 07hToggle mode (Repeat reading)
- 08hFlash mode (Pulse driven reading)
- 09hLow Power mode (Low Power triggering)

TS A Operation Mode (TS)

Descriptions

Select operation mode for Tethered A Series Scanner

TS A Operation Mode is equivalent to the Operation Mode Selection in the Set TS Operation command. It is of more convenience to use TS A Operation Mode of the Action Command Category. Available for A series

Packet Format

PrefixOpcode StatusLengthParameter(s)LRC Suffix
7Eh80h 08h 05h00h 00h 03hSee Below Variable7Eh
1 Byte3 Bytes 1 Byte 2 Bytes3 Bytes 1 Byte 1 Byte

. Host Requirements

If the device successfully received the above command issued by the host, a "Device ACK" will be sent to the host right after the device performed the action. Otherwise, a "Device NAK" will be sent to host to issue a command error. However, if the host can not receive any response from the device within the user preset time-out duration, please resend the above command.

. Length

Total size (bytes) of the Parameter(s) field

.LRC

"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"

Parameter(s)

< Table 4-6 > TS A Operation Mode Parameter(s) Field

Parameter / PID / SizeOptionsDescriptions
TS A Operation ModePID :Size : 00h 03h (3 Byte)- 00h 01h 01h- 01h 01h 01h- 02h 01h 01h- 04h 01h 00h- 05h 01h 01h- 06h 01h 00h- 07h 01h 00h- 09h 01h 01h- 0Dh 01h 01hTrigger mode *Force modePresentation modeLevel modeDiagnostic modeAlternative modeToggle modeLow Power modeMultiple mode

Paging (WF)

Descriptions

Paging the scanner

This command is helpful for you to locate the connected Wi-Fi scanner.

Available for F & L series

Packet Format

PrefixOpcode StatusLengthParameter(s)LRC Suffix
7Eh80h 90h 01h00h 00h 00h5Ch 04h 7Eh
1 Byte3 Bytes 1 Byte2 Bytes0 Byte 1 Byte1 Byte

. Host Requirements

If the device successfully received the above command issued by the host, a “Device ACK” will be sent to the host right after the device performed the action. Otherwise, a “Device NAK” will be sent to host to issue a command error. However, if the host can not receive any response from the device within the user preset time-out duration, please resend the above command.

. Parameter(s) Field

Store Configuration command takes no parameters, so the Parameter(s) field is null.

. Length

Total size (bytes) of the Parameter(s) field

. LRC

"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"

Serial Command

Paging the scanner

0x7e 0x80 0x90 0x01 0x00 0x00 0x00 0x5c 0x04 0x7e

. Notes

0x5C 0x04: the escaped value of 0x11.

Remote Indication (WF)

Descriptions

Send remote indication to the connected scanner

Available for F & L series

Packet Format

PrefixOpcodeStatusLengthParameter(s)LRCSuffix
7Eh80h90h 02h00h 02h00hSee Next PageVariable7Eh
1 Byte3Bytes1 Byte2 Bytes512 Bytes1 Byte1 Byte

. Host Requirements

If the device successfully received the above command issued by the host, a "Device ACK" will be sent to the host right after the device performed the action. Otherwise, a "Device NAK" will be sent to host to issue a command error. However, if the host can not receive any response from the device within the user preset time-out duration, please resend the above command.

. Length

Total size (bytes) of the Parameter(s) field

.LRC

"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"

Parameter(s)

SizeParameter Value
2 BytesCode Page00h 00h
1 ByteClose00h
1 ByteMessage Type07h
1 ByteBit 4~7Beeping Type- 0h Short- 1h Long
Bit 0~3Number of Beep(s)- 0h Disable- 1h Once- 2h 2 times- 3h 3 times- 5h 5 times- 8h 8 times- Ah 10 times
1 ByteBit 4~7Vibration Duration- 1h 100ms- 2h 200ms- 3h 300ms- 4h 400ms- 5h 500ms
Bit 0~3Number of Vibration- 0h Disable- 1h 1 time- 2h 2 times- 3h 3 times- 4h 4 times- 5h 5 times
3 BytesMessage Length00h 00h 00h
503 BytesMessage Content00h 00h ...00h

Remote Message (WF)

Descriptions

Send remote message to the connected scanner

Available for F & L series

Packet Format

PrefixOpcodeStatusLengthParameter(s)LRCSuffix
7Eh80h90h 02h00h 02h 00hSee Next PageVariable7Eh
1 Byte3Bytes1 Byte2 Bytes512 Bytes1 Byte1 Byte

. Host Requirements

If the device successfully received the above command issued by the host, a "Device ACK" will be sent to the host right after the device performed the action. Otherwise, a "Device NAK" will be sent to host to issue a command error. However, if the host can not receive any response from the device within the user preset time-out duration, please resend the above command.

.Length

Total size (bytes) of the Parameter(s) field

.LRC

"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"

Parameter(s)

SizeParameter Value
2 BytesCode PageXXh XXh (See Notes)
1 ByteBit 7Manual Close-0 Disable(See Notes)-1 Enable
Bit 0~6Auto Close-0h Disable(See Notes)-3h after 3 seconds-5h after 5 seconds-8h after 8 seconds-Ah after 10 seconds
1 ByteBit 7~6Left AlignSet Bit 7 to 1, Bit 6 to 0
Right AlignSet Bit 7 to 0, Bit 6 to 1
Center AlignSet both Bit 7 and Bit 6 to 1 or 0
Bit 5~0Message Type-0h Tips-1h Warning-2h Question-3h Information-4h Error
1 ByteBit 4~7Beeping Type-0h Short-1h Long
Bit 0~3Number of Beep-0h Disable-1h Once-2h 2 times-3h 3 times-5h 5 times-8h 8 times-Ah 10 times
1 ByteBit 4~7Vibration Duration-1h 100ms-2h 200ms-3h 300ms-4h 400ms-5h 500ms
Bit 0~3Number of Vibration-0h Disable-1h 1 time-2h 2 times-3h 3 times-4h 4 times-5h 5 times
3 BytesMessage LengthXXh XXh XXh (See Notes)
503 BytesMessage ContentXXh... (See Notes)

.Notes

  1. The following Chart lists all available Code Pages and their 2-byte Hex value.
437 OEM - United States B5h 01h
737 OEM - Greek (formerly 437G) E1h 02h
850 OEM - Multilingual Latin I 52h 03h
852 OEM - Latin II 54h 03h
855 OEM - Cyrillic 57h 03h
857 OEM - Turkish 59h 03h
860 OEM - Portuguese 5Ch 03h
863 OEM - French Canadian 5Fh 03h
865 OEM - Nordic 61h 03h
866 OEM - Russian 62h 03h
932 ANSI/OEM Japanese (Shift-JIS) A4h 03h
936 ANSI/OEM - Simplified Chinese (GB2312) A8h 03h
950 ANSI/OEM - Traditional Chinese (Big5) B6h 03h
1250 ANSI - Central EuropeanE2h 04h
1251 ANSI - CyrillicE3h 04h
1252 ANSI - Latin 1E4h 04h
1253 ANSI - GreekE5h 04h
1254 ANSI - TurkishE6h 04h
1255 ANSI - HebrewE7h 04h
  1. Manual Close and Auto Close can not be disabled at the same time.
  2. Message Length has at most three bytes. If the first byte is 0xFF, the following two bytes represent the content length, formatted as High Byte Low Byte. Otherwise, the first byte represents the content length itself, and the following two bytes will become part of the message content.
  3. Message Content uses Little-endian UCS-2 character set. If shorter than 503 bytes, the rest bytes should be set to 00h.

Command Descriptions

Remote Clear (WF)

Descriptions

Clear the remote message

The scanner will beep twice and vibrate for 100 milliseconds at the same time.

Available for F & L series

Packet Format

PrefixOpcodeStatusLengthParameter(s)LRCSuffix
7Eh80h90h 02h00h 02h00h00h 00h 00h00h 00h ... 00h08h18h7Eh
1 Byte3Bytes1 Byte2 Bytes512 Bytes1 Byte1 Byte

. Host Requirements

If the device successfully received the above command issued by the host, a "Device ACK" will be sent to the host right after the device performed the action. Otherwise, a "Device NAK" will be sent to host to issue a command error. However, if the host can not receive any response from the device within the user preset time-out duration, please resend the above command.

. Length

Total size (bytes) of the Parameter(s) field

.LRC

"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"

Remote Lock (WF)

Descriptions

Send remote message to the connected scanner

Note that a locked scanner can not work until the Remote Unlock is called.

Available for F & L series

Packet Format

PrefixOpcodeStatusLengthParameter(s)LRCSuffix
7Eh80h90h 02h00h 02h 00hSee Next Page Variable7Eh
1 Byte3Bytes1 Byte2 Bytes512 Bytes1 Byte1 Byte

. Host Requirements

If the device successfully received the above command issued by the host, a "Device ACK" will be sent to the host right after the device performed the action. Otherwise, a "Device NAK" will be sent to host to issue a command error. However, if the host can not receive any response from the device within the user preset time-out duration, please resend the above command.

. Length

Total size (bytes) of the Parameter(s) field

.LRC

"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"

Parameter(s)

SizeParameter Value
2 BytesCode PageXXh XXh (See Notes)
1 ByteClose00h
1 ByteBit 7~6Left AlignSet Bit 7 to 1, Bit 6 to 0
Right AlignSet Bit 7 to 0, Bit 6 to 1
Center AlignSet both Bit 7 and Bit 6 to 1 or 0
Bit 5~0Message Type-5h
1 ByteBit 4~7Beeping Type-0h Short-1h Long
Bit 0~3Number of Beep-0h Disable-1h Once-2h 2 times-3h 3 times-5h 5 times-8h 8 times-Ah 10 times
1 ByteBit 4~7Vibration Duration-1h 100ms-2h 200ms-3h 300ms-4h 400ms-5h 500ms
Bit 0~3Number of Vibration-0h Disable-1h 1 time-2h 2 times-3h 3 times-4h 4 times-5h 5 times
3 BytesMessage LengthXXh XXh XXh (See Notes)
503 BytesMessage ContentXXh... (See Notes)

.Notes

  1. The following Chart lists all available Code Pages and their 2-byte Hex value.
437 OEM - United States B5h 01h
737 OEM - Greek (formerly 437G) E1h 02h
850 OEM - Multilingual Latin I 52h 03h
852 OEM - Latin II 54h 03h
855 OEM - Cyrillic 57h 03h
857 OEM - Turkish 59h 03h
860 OEM - Portuguese 5Ch 03h
863 OEM - French Canadian 5Fh 03h
865 OEM - Nordic 61h 03h
866 OEM - Russian 62h 03h
932 ANSI/OEM Japanese (Shift-JIS) A4h 03h
936 ANSI/OEM - Simplified Chinese (GB2312) A8h 03h
950 ANSI/OEM - Traditional Chinese (Big5) B6h 03h
1250 ANSI - Central EuropeanE2h 04h
1251 ANSI - CyrillicE3h 04h
1252 ANSI - Latin 1E4h 04h
1253 ANSI - GreekE5h 04h
1254 ANSI - TurkishE6h 04h
1255 ANSI - HebrewE7h 04h
  1. Manual Close and Auto Close can not be disabled at the same time.
  2. Message Length has at most three bytes. If the first byte is 0xFF, the following two bytes represent the content length, formatted as High Byte Low Byte. Otherwise, the first byte represents the content length itself, and the following two bytes will become part of the message content.
  3. Message Content uses Little-endian UCS-2 character set. If shorter than 503 bytes, the rest bytes should be set to 00h.

Remote Unlock (WF)

Descriptions

Send remote message to the connected scanner

The scanner will beep twice and vibrate for 100 milliseconds at the same time.

Available for F & L series

Packet Format

PrefixOpcodeStatusLengthParameter(s)LRCSuffix
7Eh80h90h 02h00h 02h00h00h 00h 5Ch02h00h 00h 00h 00h00h 00h ... 00h16h7Eh
1 Byte3Bytes1 Byte2 Bytes513 Bytes1 Byte1 Byte

. Host Requirements

If the device successfully received the above command issued by the host, a "Device ACK" will be sent to the host right after the device performed the action. Otherwise, a "Device NAK" will be sent to host to issue a command error. However, if the host can not receive any response from the device within the user preset time-out duration, please resend the above command.

. Length

Total size (bytes) of the Parameter(s) field

.LRC

"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"

.Notes

0x5C 0x02: the escaped value of 0x06.

Remote Programming (WF)

Descriptions

Enter or exit the Programming Mode.

Wi-Fi scanner can only perform Remote Control commands when it is not in Programming mode.

Remote Programming (Enter) is used to put scanner into programming mode, so that the subsequent programming commands will take effect. Please refer to Briefing Chapter (Page 1-2) for detailed descriptions. Note that in programming mode the scanner can not work until the Remote Programming (Exit) or Remote Programming Extension (Exit) is sent.

Available for F & L series

Packet Format

PrefixOpcodeStatusLengthParameter(s)LRCSuffix
7Eh80h90h 06h00h 00h 01hSee Below Variable7Eh
1 Byte3Bytes1 Byte2 Bytes1 Byte1 Byte1 Byte

. Host Requirements

If the device successfully received the above command issued by the host, a "Device ACK" will be sent to the host right after the device performed the action. Otherwise, a "Device NAK" will be sent to host to issue a command error. However, if the host can not receive any response from the device within the user preset time-out duration, please resend the above command.

. Length

Total size (bytes) of the Parameter(s) field

.LRC

"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"

Parameter(s)

< Table 4-7 > Remote Programming Parameter(s) Field

Parameter / PID / SizeOptionsDescriptions
Remote ProgrammingPID :Size : 00h 01h (1 Byte)- 00h- 01hExit Remote ProgrammingEnter Remote Programming

Serial Command

Enter Remote Programming

Exit Remote Programming

Remote Programming Extension (WF)

Descriptions

Enter remote programming mode with user defined message, beeps and vibration.

Wi-Fi scanner can only perform Remote Control commands when it is not in Programming mode.

Remote Programming Extension (Enter) is used to put scanner into programming mode, so that the subsequent programming commands will take effect. Please refer to Briefing Chapter (Page 1-2) for detailed descriptions.

Note that in programming mode the scanner can not work until the Remote Programming (Exit) or Remote Programming Extension (Exit) is sent.

Available for F & L series

Packet Format

PrefixOpcodeStatusLengthParameter(s)LRCSuffix
7Eh80h90h 06h00h 02h 00hSee Next Page Variable7Eh
1 Byte3Bytes1 Byte2 Bytes512 Bytes1 Byte1 Byte

. Host Requirements

If the device successfully received the above command issued by the host, a "Device ACK" will be sent to the host right after the device performed the action. Otherwise, a "Device NAK" will be sent to host to issue a command error. However, if the host can not receive any response from the device within the user preset time-out duration, please resend the above command.

. Length

Total size (bytes) of the Parameter(s) field

.LRC

"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"

Parameter(s)

SizeParameter Value
2 BytesCode PageXXh XXh (See Notes)
1 ByteBit 7Manual Close-0 Disable (See Notes)-1 Enable
Bit 0~6Auto Close-0h Disable (See Notes)-3h after 3 seconds-5h after 5 seconds-8h after 8 seconds-Ah after 10 seconds
1 ByteBit 7~6Left AlignSet Bit 7 to 1, Bit 6 to 0
Right AlignSet Bit 7 to 0, Bit 6 to 1
Center AlignSet both Bit 7 and Bit 6 to 1 or 0
Bit 5~0Message Type - 0h ExitProgramming Mode-1h Enter Programming Mode
1 ByteBit 4~7Beeping Type-0h Short-1h Long
Bit 0~3Number of Beep-0h Disable-1h Once-2h 2 times-3h 3 times-5h 5 times-8h 8 times-Ah 10 times
1 ByteBit 4~7Vibration Duration-1h 100ms-2h 200ms-3h 300ms-4h 400ms-5h 500ms
Bit 0~3Number of Vibration-0h Disable-1h 1 time-2h 2 times-3h 3 times-4h 4 times-5h 5 times
3 BytesMessage LengthXXh XXh XXh (See Notes)
503 BytesMessage ContentXXh... (See Notes)

.Notes

  1. The following Chart lists all available Code Pages and their 2-byte Hex value.
437 OEM - United States B5h 01h
737 OEM - Greek (formerly 437G) E1h 02h
850 OEM - Multilingual Latin I 52h 03h
852 OEM - Latin II 54h 03h
855 OEM - Cyrillic 57h 03h
857 OEM - Turkish59h03h
860 OEM - Portuguese5Ch03h
863 OEM - French Canadian5Fh03h
865 OEM - Nordic61h03h
866 OEM - Russian62h03h
932 ANSI/OEM Japanese (Shift-JIS)A4h03h
936 ANSI/OEM - Simplified Chinese (GB2312)A8h03h
950 ANSI/OEM - Traditional Chinese (Big5)B6h03h
1250ANSI - Central EuropeanE2h 04h
1251ANSI - CyrillicE3h 04h
1252ANSI - Latin 1E4h 04h
1253ANSI - GreekE5h 04h
1254ANSI - TurkishE6h 04h
1255ANSI - HebrewE7h 04h
  1. Manual Close and Auto Close can not be disabled at the same time. And they are available for Exit Programming Mode only.
  2. Message Length has at most three bytes. If the first byte is 0xFF, the following two bytes represent the content length, formatted as High Byte Low Byte. Otherwise, the first byte represents the content length itself, and the following two bytes will become part of the message content.
  3. Message Content uses Little-endian UCS-2 character set. If shorter than 503 bytes, the rest bytes should be set to 00h.

Sync Date Time (WF)

Descriptions

Set Date Time

Available for F & L series

Packet Format

PrefixOpcode StatusLengthParameter(s)LRC Suffix
7Eh80h 30h 00h00h 00h 07hSee Below Variable7Eh
1 Byte3 Bytes 1 Byte 2 Bytes7 Bytes 1 Byte 1 Byte

. Host Requirements

If the device successfully received the above command issued by the host, a "Device ACK" will be sent to the host right after the device performed the action. Otherwise, a "Device NAK" will be sent to host to issue a command error. However, if the host can not receive any response from the device within the user preset time-out duration, please resend the above command.

. Length

Total size (bytes) of the Parameter(s) field

.LRC

"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"

Parameter(s)

< Table 1-8 > Sync Date Time Parameter(s) Field

Parameter / PID / SizeOptionsDescriptions
Sync Date TimePID :Size : 00h 07h (7 Bytes) 1^st 2^nd Byte- XXh XXh 3^rd Byte- XXh 4^th Byte- XXh 5^th Byte- XXh 6^th Byte- XXh 7^th Byte- XXhYear(For example: 14h 0Ch stands for 2012)Month(See Notes)DayHourMinuteSecond

.Notes

  1. Date Time values are described in Hex Value. For example, to set 16:13:03 Feb. 27, 2012, the parameter field should be: 14h 0Ch 02h 1Bh 10h 0Dh 03h.

Delete Record (WF)

Descriptions

Delete all record(s) of Batch Mode

Available for F & L series

Packet Format

PrefixOpcode StatusLengthParameter(s)LRC Suffix
7Eh80h 11h 00h00h 00h 00h<Null> 91h 7Eh
1 Byte 3Bytes 1 Byte 2 Bytes0 Byte 1 Byte1 Byte

. Host Requirements

If the device successfully received the above command issued by the host, a "Device ACK" will be sent to the host right after the device performed the action. Otherwise, a "Device NAK" will be sent to host to issue a command error. However, if the host can not receive any response from the device within the user preset time-out duration, please resend the above command.

. Length

Total size (bytes) of the Parameter(s) field

.LRC

"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"

Send STerm Data (WF)

Descriptions

This command is used to send Stern Page Data when works with WaveCentre.

It is sent by the host application to the WaveCentre.

Available for F & L series

Packet Format

PrefixOpcode StatusLengthParameter(s)LRC Suffix
7Eh80h 80h 00h00h VariableVariable Variable7Eh
1 Byte3 Bytes 1 Byte 4 BytesVariable 1 Byte 1 Byte

. Host Requirements

There is no response for this message.

. Parameter

The Page Packet Body

. Length

Total size (bytes) of the Parameter(s) field

.LRC

"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"

2.5 Interface

Set USB COM (TS, SE, FM)

Descriptions

Change the desired one or more parameters of the USB COM Interface settings

Available for F, L & A series; SE380, SE390 & SE480 series; FM480 & SM380 series; FA470 & SM5700 Series

Packet Format

PrefixOpcodeStatusLengthParameter(s)LRCSuffix
7Eh82h00h03h00hVariableSee BelowVariable7Eh
1 Byte3Bytes1 Byte2 BytesVariable1 Byte1 Byte
Parameter(s)
First Parameter......Last Parameter
PIDSizeOptions......PIDSizeOptions
2 Bytes2 BytesVariable......2 Bytes2 BytesVariable
See Next Page

. Host Requirements

If the device successfully received the above command issued by the host, a "Device ACK" will send to the host right after the device performed the action. Otherwise, a "Device NAK" will be sent to host to issue a command error. However, if the host can not receive any response from the device within the user preset time-out duration, please resend the above command.

. Parameter(s) Field

Set USB COM can change multiple parameters at one time, so it takes compound parameters.

. Length

Total size (bytes) of the Parameter(s) field

.LRC

"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"

. Size

Total size (bytes) of the Options field

Parameter(s)

< Table 5-1-1 > Set USB COM Parameter(s) Field

Parameter / PID / Size Options Descriptions
STX/ETX TransmissionPID : 00h 00hSize : 00h 01h (1 Byte)- 00h- 01hDisable *Enable
Handshaking ProtocolPID : 00h 01hSize : 00h 03h (3 Bytes) 1^st 3^rd Byte- 00h 00h 00h- 00h 00h 01h- 00h 01h 00hNone *ACK/NAKXon/Xoff
Baud RatePID : 00h 02hSize : 00h 01h (1 Byte)- 02h- 03h- 04h- 05h- 06h- 07h- 08h- 09h1200 BPS2400 BPS4800 BPS9600 BPS *19200 BPS38400 BPS57600 BPS115200 BPS
Data Frame(Data Bit, Parity, Stop Bit )PID : 00 03Size : 00h 01h (1 Byte)- 02h- 05h- 08h- 09h- 0Ah- 0Bh8, None, 1 *8, Even, 18, Odd, 18, None, 28, Space, 18, Mark, 1
Serial Response Time-outPID : 00h 04hSize : 00h 01h (1 Byte)- 01h- 04h- 09h- 0Fh- 12h- 24h- 4Fh- 50h- 48h- 56h- 5Ah- 61hNone200 ms500 ms *800 ms1 s2 s3 s4 s5 s8 s10 s15 s
ACK/NAK Retry CountPID : 00h 05hSize : 00h 01h (1 Byte)- 03h- XXh3 times * (See Note)User-defined: XXh =desired seconds(h)
ACK/NAK IndicationPID : 00h 06hSize : 00h 01h (1 Byte)Bit 0- 0- 1Bit 1 ~ 7ACK/NAK Transmission Fail IndicationDisableEnable *Reserved (Always 0)

. Notes

ACK/NAK Retry Count ranges from 00h (never retry) to FFh (always retry).

Get USB COM (TS, SE, FM)

Descriptions

Request the desired one or more parameters of the USB COM Interface settings

Available for F, L & A series; SE380, SE390 & SE480 series; FM480 & SM380 series; FA470 & SM5700 Series

Packet Format

PrefixOpcodeStatusLengthParameter(s)LRCSuffix
7EhC3h 00h 03h00hVariableSee Below Variable7Eh
1 Byte3Bytes1 Byte2 BytesVariable1 Byte1 Byte
Parameter(s)
First Parameter......Last Parameter
PID Size......PID Size
2 Bytes2 Bytes......2 Bytes2 Bytes
See Next Page

. Host Requirements

If the device successfully received the above command issued by the host, the device will pack all requested parameters into a "Reply USB COM" message string then send to the host. Please refer to the "Reply USB COM" command for details. Otherwise, a "Device NAK" will be sent to host to indicate issue a command error. However, if the host can receive any response from the device within the user preset time-out duration, please resend the above command.

. Parameter(s) Field

Get USB COM can request multiple parameters at one time, so it takes compound parameters.

. Length

Total size (bytes) of the Parameter(s) field

.LRC

"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"

. Size

Total size (bytes) of the Options field

Parameter(s)

< Table 5-1-2 > Get USB COM Parameter(s) Field

Parameter PID Size
STX/ETX Transmission 00h 00h00h 00h
Handshaking Protocol 00h 01h00h 00h
Baud Rate 00h 02h00h 00h
Data Frame 00h 03h00h 00h
Serial Response Time-out 00h 04h00h 00h
ACK/NAK Retry Count 00h 05h00h 00h
ACK/NAK Indication 00h 06h00h 00h

Reply USB COM (TS, SE, FM)

Descriptions

Reply the desired one or more parameters of the USB COM Interface settings

Reply USB COM is sent by the device in response to the Get USB COM command. It sends the values for all the desired parameters requested in the Get USB COM command.

Available for F, L & A series; SE380, SE390 & SE480 series; FM480 & SM380 series; FA470 & SM5700 Series

Packet Format

PrefixOpcodeStatusLengthParameter(s)LRCSuffix
7Eh04h00h03h00hVariableSee Below Variable7Eh
1 Byte3 Bytes1 Byte2 BytesVariable1 Byte1 Byte
Parameter(s)
First Parameter......Last Parameter
PIDSizeOptions......PIDSizeOptions
2 Bytes2 BytesVariable......2 Bytes2 BytesVariable
See Next Page
Parameter(s)
First Parameter......Last Parameter
PIDSizeOptions......PIDSizeOptions
2 Bytes2 BytesVariable......2 Bytes2 BytesVariable
See Next Page

. Host Requirements

Since Reply USB COM is a device-to-host message, there is no response for this message.

. Parameter(s) Field

Set USB COM can change multiple parameters at one time, so it takes compound parameters.

. Length

Total size (bytes) of the Parameter(s) field

.LRC

"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"

. Size

Total size (bytes) of the Options field

Parameter(s)

< Table 5-1-3 > Reply USB COM Parameter(s) Field

Parameter / PID / Size Options Descriptions
STX/ETX TransmissionPID : 00h 00hSize : 00h 01h (1 Byte)- 00h- 01hDisable *Enable
Handshaking ProtocolPID : 00h 01hSize : 00h 03h (3 Bytes) 1^st 3^rd Byte- 00h 00h 00h- 00h 00h 01h- 00h 01h 00hNone *ACK/NAKXon/Xoff
Baud RatePID : 00h 02hSize : 00h 01h (1 Byte)- 02h- 03h- 04h- 05h- 06h- 07h- 08h- 09h1200 BPS2400 BPS4800 BPS9600 BPS *19200 BPS38400 BPS57600 BPS115200 BPS
Data Frame(Data Bit, Parity, Stop Bit )PID : 00 03Size : 00h 01h (1 Byte)- 02h- 05h- 08h- 09h- 0Ah- 0Bh8, None, 1 *8, Even, 18, Odd, 18, None, 28, Space, 18, Mark, 1
Serial Response Time-outPID : 00h 04hSize : 00h 01h (1 Byte)- 01h- 04h- 09h- 0Fh- 12h- 24h- 4Fh- 50h- 48h- 56h- 5Ah- 61hNone200 ms500 ms *800 ms1 s2 s3 s4 s5 s8 s10 s15 s
ACK/NAK Retry CountPID : 00h 05hSize : 00h 01h (1 Byte)- 03h- XXh3 times * (See Note)User-defined: XXh =desired seconds(h)
ACK/NAK IndicationPID : 00h 06hSize : 00h 01h (1 Byte)Bit 0- 0- 1Bit 1 ~ 7ACK/NAK Transmission Fail IndicationDisableEnable *Reserved (Always 0)

.Notes

ACK/NAK Retry Count ranges from 00h (never retry) to FFh (always retry).

Set RS232 (TS, SE, FM)

Descriptions

Change the desired one or more parameters of the RS232 Interface settings

Available for F, L & A series; SE380, SE390 & SE480 series; FM480 & SM380 series; FA470 & SM5700 Series

Packet Format

PrefixOpcodeStatusLengthParameter(s)LRCSuffix
7Eh82h00h00hVariableSee BelowVariable7Eh
1 Byte3Bytes1 Byte2 BytesVariable1 Byte1 Byte
Parameter(s)
First Parameter......Last Parameter
PIDSizeOptions......PIDSizeOptions
2 Bytes2 BytesVariable......2 Bytes2 BytesVariable
See Next Page

. Host Requirements

If the device successfully received the above command issued by the host, a "Device ACK" will send to the host right after the device performed the action. Otherwise, a "Device NAK" will be sent to host to issue a command error. However, if the host can not receive any response from the device within the user preset time-out duration, please resend the above command.

. Parameter(s) Field

Set RS232 command can change multiple parameters at one time, so it takes compound parameters.

. Length

Total size (bytes) of the Parameter(s) field

.LRC

"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"

. Size

Total size (bytes) of the Options field

Parameter(s)

< Table 5-2-1 > Set RS232 Parameter(s) Field

Parameter / PID / Size Options Descriptions
STX/ETX TransmissionPID : 00h 00hSize : 00h 01h (1 Byte)- 00h- 01hDisable *Enable
Handshaking ProtocolPID : 00h 01hSize : 00h 03h (3 Bytes) 1^st 3^rd Byte- 00h 00h 00h- 01h 00h 00h- 00h 00h 01h- 00h 01h 00hNone *RTS/CTSACK/NAKXon/Xoff
Baud RatePID : 00h 02hSize : 00h 01h (1 Byte)- 02h- 03h- 04h- 05h- 06h- 07h- 08h- 09h1200 BPS2400 BPS4800 BPS9600 BPS *19200 BPS38400 BPS57600 BPS115200 BPS
Data Frame(Data Bit, Parity, Stop Bit )PID : 00 03Size : 00h 01h (1 Byte)- 02h- 05h- 08h- 09h- 0Ah- 0Bh8, None, 1 *8, Even, 18, Odd, 18, None, 28, Space, 18, Mark, 1
Serial Response Time-outPID : 00h 04hSize : 00h 01h (1 Byte)- 01h- 04h- 09h- 0Fh- 12h- 24h- 4Fh- 50h- 48h- 56h- 5Ah- 61hNone200 ms500 ms *800 ms1 s2 s3 s4 s5 s8 s10 s15 s
ACK/NAK Retry CountPID : 00h 05hSize : 00h 01h (1 Byte)- 03h- XXh3 times * (See Note)User-defined: XXh =desired seconds(h)
ACK/NAK IndicationPID : 00h 06hSize : 00h 01h (1 Byte)Bit 0- 0- 1Bit 1 ~ 7ACK/NAK Transmission Fail IndicationDisableEnable *Reserved (Always 0)

Notes

ACK/NAK Retry Count ranges from 00h (never retry) to FFh (always retry).

Get RS232 (TS, SE, FM)

Descriptions

Request the desired one or more parameters of the RS232 Interface settings

Available for F, L & A series; SE380, SE390 & SE480 series; FM480 & SM380 series; FA470 & SM5700 Series

Packet Format

PrefixOpcodeStatusLengthParameter(s)LRCSuffix
7EhC3h00h00hVariableSee BelowVariable7Eh
1 Byte3Bytes1 Byte2 BytesVariable1 Byte1 Byte
Parameter(s)
First Parameter......Last Parameter
PID Size......PID Size
2 Bytes2 Bytes......2 Bytes2 Bytes
See Next Page

. Host Requirements

If the device successfully received the above command issued by the host, the device will pack all requested parameters into a "Reply RS232" message string then send to the host. Please refer to the "Reply RS232" command for details. Otherwise, a "Device NAK" will be sent to host to indicate issue a command error. However, if the host can receive any response from the device within the user preset time-out duration, please resend the above command.

. Parameter(s) Field

Get RS232 command can request multiple parameters at one time, so it takes compound parameters.

. Length

Total size (bytes) of the Parameter(s) field

.LRC

"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"

. Size

Total size (bytes) of the Options field

Parameter(s)

< Table 5-2-2 > Get RS232 Parameter(s) Field

Parameter PID Size
STX/ETX Transmission 00h 00h00h 00h
Handshaking Protocol 00h 01h00h 00h
Baud Rate 00h 02h00h 00h
Data Frame 00h 03h00h 00h
Serial Response Time-out 00h 04h00h 00h
ACK/NAK Retry Count 00h 05h00h 00h
ACK/NAK Indication 00h 06h00h 00h

Reply RS232 (TS, SE, FM)

Descriptions

Reply RS232 Interface Settings

Reply RS232 is sent by the device in response to the Get RS232 command. It sends the values for all the desired parameters requested in the Get RS232 command.

Available for F, L & A series; SE380, SE390 & SE480 series; FM480 & SM380 series; FA470 & SM5700 Series

Packet Format

PrefixOpcodeStatusLengthParameter(s)LRCSuffix
7Eh04h00h00hVariableSee BelowVariable7Eh
1 Byte3Bytes1 Byte2 BytesVariable1 Byte1 Byte
Parameter(s)
First Parameter......Last Parameter
PIDSizeOptions......PIDSizeOptions
2 Bytes2 BytesVariable......2 Bytes2 BytesVariable
See Next Page

. Host Requirements

Since Reply RS232 is a device-to-host message, there is no response for this message.

. Parameter(s) Field

Set RS232 command can change multiple parameters at one time, so it takes compound parameters.

. Length

Total size (bytes) of the Parameter(s) field

.LRC

"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"

. Size

Total size (bytes) of the Options field

Parameter(s)

< Table 5-2-3 > Reply RS232 Parameter(s) Field

Parameter / PID / Size Options Descriptions
STX/ETX TransmissionPID : 00h 00hSize : 00h 01h (1 Byte)- 00h- 01hDisable *Enable
Handshaking ProtocolPID : 00h 01hSize : 00h 03h (3 Bytes) 1^st 3^rd Byte- 00h 00h 00h- 01h 00h 00h- 00h 00h 01h- 00h 01h 00hNone *RTS/CTSACK/NAKXon/Xoff
Baud RatePID : 00h 02hSize : 00h 01h (1 Byte)- 02h- 03h- 04h- 05h- 06h- 07h- 08h- 09h1200 BPS2400 BPS4800 BPS9600 BPS *19200 BPS38400 BPS57600 BPS115200 BPS
Data Frame(Data Bit, Parity, Stop Bit )PID : 00 03Size : 00h 01h (1 Byte)- 02h- 05h- 08h- 09h- 0Ah- 0Bh8, None, 1 *8, Even, 18, Odd, 18, None, 28, Space, 18, Mark, 1
Serial Response Time-outPID : 00h 04hSize : 00h 01h (1 Byte)- 01h- 04h- 09h- 0Fh- 12h- 24h- 4Fh- 50h- 48h- 56h- 5Ah- 61hNone200 ms500 ms *800 ms1 s2 s3 s4 s5 s8 s10 s15 s
ACK/NAK Retry CountPID : 00h 05hSize : 00h 01h (1 Byte)- 03h- XXh3 times * (See Note)User-defined: XXh =desired seconds(h)
ACK/NAK IndicationPID : 00h 06hSize : 00h 01h (1 Byte)Bit 0- 0- 1Bit 1 ~ 7ACK/NAK Transmission Fail IndicationDisableEnable *Reserved (Always 0)

.Notes

ACK/NAK Retry Count ranges from 00h (never retry) to FFh (always retry).

Command Descriptions

Set USB COM (BT)

Descriptions

Change the desired one or more parameters of the USB COM Interface settings

Available for F, L & A series

Packet Format

PrefixOpcodeStatusLengthParameter(s)LRCSuffix
7Eh82h00h03h00hVariableSee BelowVariable7Eh
1 Byte3Bytes1 Byte2 Bytes/Variable 1 Byte1 Byte
Parameter(s)
First Parameter......Last Parameter
PIDSizeOptions......PIDSizeOptions
2 Bytes2 BytesVariable......2 Bytes2 BytesVariable
See Next Page

. Host Requirements

If the device successfully received the above command issued by the host, a "Device ACK" will send to the host right after the device performed the action. Otherwise, a "Device NAK" will be sent to host to issue a command error. However, if the host can not receive any response from the device within the user preset time-out duration, please resend the above command.

. Parameter(s) Field

Set USB COM can change multiple parameters at one time, so it takes compound parameters.

. Length

Total size (bytes) of the Parameter(s) field

.LRC

"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"

. Size

Total size (bytes) of the Options field

Parameter(s)

< Table 5-3-1 > Set USB COM Parameter(s) Field

Parameter / PID / Size Options Descriptions
STX/ETX TransmissionPID : 00h 00hSize : 00h 01h (1 Byte)- 00h- 01hDisable *Enable
Baud RatePID : 00h 02hSize : 00h 01h (1 Byte)- 02h- 03h- 04h- 05h- 06h- 07h- 08h- 09h1200 BPS2400 BPS4800 BPS9600 BPS *19200 BPS38400 BPS57600 BPS115200 BPS
Data Frame(Data Bit, Parity, Stop Bit )PID : 00 03Size : 00h 01h (1 Byte)- 02h- 08h- 05h- 0Ah- 0Bh- 09h- 06h- 03h- 0Ch- 0Dh- 01h- 07h- 04h- 0Eh- 0Fh8, None, 1 *8, Odd, 18, Even, 18, Space, 18, Mark, 18, None, 27, Odd, 17, Even, 17, Space, 17, Mark, 17, None, 27, Odd, 27, Even, 27, Space, 27, Mark, 2

Get USB COM (BT)

Descriptions

Request the desired one or more parameters of the USB COM Interface settings

Available for F, L & A series

Packet Format

PrefixOpcodeStatusLengthParameter(s)LRCSuffix
7EhC3h00h03h00hVariableSee BelowVariable7Eh
1 Byte3Bytes1 Byte2 BytesVariable1 Byte1 Byte
Parameter(s)
First Parameter......Last Parameter
PID Size ......PID Size
2 Bytes2 Bytes......2 Bytes2 Bytes
See Next Page

. Host Requirements

If the device successfully received the above command issued by the host, the device will pack all requested parameters into a "Reply USB COM" message string then send to the host. Please refer to the "Reply USB COM" command for details. Otherwise, a "Device NAK" will be sent to host to indicate issue a command error. However, if the host can receive any response from the device within the user preset time-out duration, please resend the above command.

. Parameter(s) Field

Get USB COM can request multiple parameters at one time, so it takes compound parameters.

. Length

Total size (bytes) of the Parameter(s) field

.LRC

"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"

. Size

Total size (bytes) of the Options field

Parameter(s)

< Table 5-3-2 > Get USB COM Parameter(s) Field

Parameter PID Size
STX/ETX Transmission 00h 00h00h 00h
Baud Rate 00h 02h00h 00h
Data Frame 00h 03h00h 00h

Reply USB COM (BT)

Descriptions

Reply the desired one or more parameters of the USB COM Interface settings

Reply USB COM is sent by the device in response to the Get USB COM command. It sends the values for all the desired parameters requested in the Get USB COM command.

Available for F, L & A series

Packet Format

PrefixOpcodeStatusLengthParameter(s)LRCSuffix
7Eh04h00h03h00hVariableSee Below Variable7Eh
1 Byte3Bytes1 Byte2 Bytes/Variable1 Byte
Parameter(s)
First Parameter......Last Parameter
PIDSizeOptions......PIDSizeOptions
2 Bytes2 BytesVariable......2 Bytes2 BytesVariable
See Next Page

. Host Requirements

Since Reply USB COM is a device-to-host message, there is no response for this message.

. Parameter(s) Field

Set USB COM can change multiple parameters at one time, so it takes compound parameters.

. Length

Total size (bytes) of the Parameter(s) field

.LRC

"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"

. Size

Total size (bytes) of the Options field

Parameter(s)

< Table 5-3-3 > Reply USB COM Parameter(s) Field

Parameter / PID / Size Options Descriptions
STX/ETX TransmissionPID : 00h 00hSize : 00h 01h (1 Byte)- 00h- 01hDisable *Enable
Baud RatePID : 00h 02hSize : 00h 01h (1 Byte)- 02h- 03h- 04h- 05h- 06h- 07h- 08h- 09h1200 BPS2400 BPS4800 BPS9600 BPS *19200 BPS38400 BPS57600 BPS115200 BPS
Data Frame(Data Bit, Parity, Stop Bit )PID : 00 03Size : 00h 01h (1 Byte)- 02h- 08h- 05h- 0Ah- 0Bh- 09h- 06h- 03h- 0Ch- 0Dh- 01h- 07h- 04h- 0Eh- 0Fh8, None, 1 *8, Odd, 18, Even, 18, Space, 18, Mark, 18, None, 27, Odd, 17, Even, 17, Space, 17, Mark, 17, None, 27, Odd, 27, Even, 27, Space, 27, Mark, 2

Set RS232 (BT)

Descriptions

Change the desired one or more parameters of the RS232 Interface settings

Available for F, L & A series

Packet Format

PrefixOpcodeStatusLengthParameter(s)LRCSuffix
7Eh82h00h00hVariableSee Below Variable7Eh
1 Byte3Bytes1 Byte2 BytesVariable1 Byte1 Byte
Parameter(s)
First Parameter......Last Parameter
PIDSizeOptions......PIDSizeOptions
2 Bytes2 BytesVariable......2 Bytes2 BytesVariable
See Next Page

. Host Requirements

If the device successfully received the above command issued by the host, a "Device ACK" will send to the host right after the device performed the action. Otherwise, a "Device NAK" will be sent to host to issue a command error. However, if the host can not receive any response from the device within the user preset time-out duration, please resend the above command.

. Parameter(s) Field

Set RS232 command can change multiple parameters at one time, so it takes compound parameters.

. Length

Total size (bytes) of the Parameter(s) field

.LRC

"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"

. Size

Total size (bytes) of the Options field

Parameter(s)

< Table 5-4-1 > Set RS232 Parameter(s) Field

Parameter / PID / Size Options Descriptions
STX/ETX TransmissionPID : 00h 00hSize : 00h 01h (1 Byte)- 00h- 01hDisable *Enable
Handshaking ProtocolPID : 00h 01hSize : 00h 03h (3 Bytes) 1^st 3^rd Byte- 00h 00h 00h- 01h 00h 00h- 00h 00h 01h- 00h 01h 00hNone *RTS/CTSACK/NAKXon/Xoff
Baud RatePID : 00h 02hSize : 00h 01h (1 Byte)- 02h- 03h- 04h- 05h- 06h- 07h- 08h- 09h1200 BPS2400 BPS4800 BPS9600 BPS *19200 BPS38400 BPS57600 BPS115200 BPS
Data Frame(Data Bit, Parity, Stop Bit )PID : 00 03Size : 00h 01h (1 Byte)- 02h- 05h- 08h- 09h- 0Ah- 0Bh8, None, 1 *8, Even, 18, Odd, 18, None, 28, Space, 18, Mark, 1
Serial Response Time-outPID : 00h 04hSize : 00h 01h (1 Byte)- 01h- 04h- 09h- 0Fh- 12h- 24h- 4Fh- 50h- 48h- 56h- 5Ah- 61hNone200 ms500 ms *800 ms1 s2 s3 s4 s5 s8 s10 s15 s
ACK/NAK Retry CountPID : 00h 05hSize : 00h 01h (1 Byte)- 03h- XXh3 times * (See Note)User-defined: XXh =desired seconds(h)
ACK/NAK IndicationPID : 00h 06hSize : 00h 01h (1 Byte)Bit 0- 0- 1Bit 1 ~ 7ACK/NAK Transmission Fail IndicationDisableEnable *Reserved (Always 0)

. Notes

ACK/NAK Retry Count ranges from 00h (never retry) to FFh (always retry).

Get RS232 (BT)

Descriptions

Request the desired one or more parameters of the RS232 Interface settings

Available for F, L & A series

Packet Format

PrefixOpcodeStatusLengthParameter(s)LRCSuffix
7EhC3h00h00hVariableSee BelowVariable7Eh
1 Byte3Bytes1 Byte2 BytesVariable1 Byte1 Byte
Parameter(s)
First Parameter......Last Parameter
PID SizePID Size
2 Bytes2 Bytes......2 Bytes2 Bytes
See Next Page

. Host Requirements

If the device successfully received the above command issued by the host, the device will pack all requested parameters into a "Reply RS232" message string then send to the host. Please refer to the "Reply RS232" command for details. Otherwise, a "Device NAK" will be sent to host to indicate issue a command error. However, if the host can receive any response from the device within the user preset time-out duration, please resend the above command.

. Parameter(s) Field

Get RS232 command can request multiple parameters at one time, so it takes compound parameters.

. Length

Total size (bytes) of the Parameter(s) field

.LRC

"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"

. Size

Total size (bytes) of the Options field

Parameter(s)

< Table 5-4-2 > Get RS232 Parameter(s) Field

Parameter PID Size
STX/ETX Transmission 00h 00h00h 00h
Handshaking Protocol 00h 01h00h 00h
Baud Rate 00h 02h00h 00h
Data Frame 00h 03h00h 00h
Serial Response Time-out 00h 04h00h 00h
ACK/NAK Retry Count 00h 05h00h 00h
ACK/NAK Indication 00h 06h00h 00h

Reply RS232 (BT)

Descriptions

Reply RS232 Interface Settings

Reply RS232 is sent by the device in response to the Get RS232 command. It sends the values for all the desired parameters requested in the Get RS232 command.

Available for F, L & A series

Packet Format

PrefixOpcodeStatusLengthParameter(s)LRCSuffix
7Eh04h00h00hVariableSee Below Variable7Eh
1 Byte3Bytes1 Byte2 BytesVariable1 Byte1 Byte
Parameter(s)
First Parameter......Last Parameter
PIDSizeOptions......PIDSizeOptions
2 Bytes2 BytesVariable......2 Bytes2 BytesVariable
See Next Page

. Host Requirements

Since Reply RS232 is a device-to-host message, there is no response for this message.

. Parameter(s) Field

Set RS232 command can change multiple parameters at one time, so it takes compound parameters.

. Length

Total size (bytes) of the Parameter(s) field

.LRC

"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"

. Size

Total size (bytes) of the Options field

Parameter(s)

< Table 5-4-3 > Reply RS232 Parameter(s) Field

Parameter / PID / Size Options Descriptions
STX/ETX TransmissionPID : 00h 00hSize : 00h 01h (1 Byte)- 00h- 01hDisable *Enable
Handshaking ProtocolPID : 00h 01hSize : 00h 03h (3 Bytes) 1^st 3^rd Byte- 00h 00h 00h- 01h 00h 00h- 00h 00h 01h- 00h 01h 00hNone *RTS/CTSACK/NAKXon/Xoff
Baud RatePID : 00h 02hSize : 00h 01h (1 Byte)- 02h- 03h- 04h- 05h- 06h- 07h- 08h- 09h1200 BPS2400 BPS4800 BPS9600 BPS *19200 BPS38400 BPS57600 BPS115200 BPS
Data Frame(Data Bit, Parity, Stop Bit )PID : 00 03Size : 00h 01h (1 Byte)- 02h- 05h- 08h- 09h- 0Ah- 0Bh8, None, 1 *8, Even, 18, Odd, 18, None, 28, Space, 18, Mark, 1
Serial Response Time-outPID : 00h 04hSize : 00h 01h (1 Byte)- 01h- 04h- 09h- 0Fh- 12h- 24h- 4Fh- 50h- 48h- 56h- 5Ah- 61hNone200 ms500 ms *800 ms1 s2 s3 s4 s5 s8 s10 s15 s
ACK/NAK Retry CountPID : 00h 05hSize : 00h 01h (1 Byte)- 03h- XXh3 times * (See Note)User-defined: XXh =desired seconds(h)
ACK/NAK IndicationPID : 00h 06hSize : 00h 01h (1 Byte)Bit 0- 0- 1Bit 1 ~ 7ACK/NAK Transmission Fail IndicationDisableEnable *Reserved (Always 0)

.Notes

ACK/NAK Retry Count ranges from 00h (never retry) to FFh (always retry).

Command Descriptions

Set Bluetooth (BT)

Descriptions

Change the desired one or more parameters of the Bluetooth settings

Available for F, L & A series

Packet Format

PrefixOpcodeStatusLengthParameter(s)LRCSuffix
7Eh98h00h00hVariableSee Below Variable7Eh
1 Byte3Bytes1 Byte2 BytesVariable1 Byte1 Byte
Parameter(s)
First Parameter......Last Parameter
PIDSizeOptions......PIDSizeOptions
2 Bytes2 BytesVariable......2 Bytes2 BytesVariable
See Next Page

. Host Requirements

If the device successfully received the above command issued by the host, a "Device ACK" will send to the host right after the device performed the action. Otherwise, a "Device NAK" will be sent to host to issue a command error. However, if the host can not receive any response from the device within the user preset time-out duration, please resend the above command.

. Parameter(s) Field

Set USB COM can change multiple parameters at one time, so it takes compound parameters.

. Length

Total size (bytes) of the Parameter(s) field

.LRC

"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"

. Size

Total size (bytes) of the Options field

Parameter(s)

< Table 5-5-1 > Set Bluetooth Parameter(s) Field

Parameter / PID / Size Options Descriptions
Bluetooth Device Name(F & L Series)PID : 00h 00hSize : 00h 11h (17 Bytes)- 00h FFh... FFh(sixteen “FFh”s)- XXh XXh...XXhDefault * (For example: F680BT-012E)User defined(See Notes)
Bluetooth PIN CodePID : 00h 01hSize : 00h 09h (9 Bytes)- 30h...30h 00h(eight “30h”s)- XXh XXh...XXhDefaults to “00000000”User defined(See Notes)
BT AuthenticationPID : 00h 02hSize : 00h 01h (1 Byte)- 00h- 01hDisableEnable *
Sleep Timeout ControlPID : 00h 03hSize : 00h 02h (2 Bytes) 1^st Byte- 00h- 06h- XXh 2^nd Byte- 00h- 01h- XXhSleep Timeout of Connect StateNever enter sleep mode6 (x5) minutes *User defined 0~99 (x5) minutesSleep Timeout of Disconnect StateNever enter sleep mode1 minute *User defined 0~99 minutes
Link Supervision TimeoutPID : 00h 04hSize : 00h 01h (1 Byte)- 00h- 01h- 02h- 03h- 04h1 s3 s *5 s7 s9 s
HID Link Quality SettingPID : 00h 05hSize : 00h 01h (1 Byte)- 00h- 01hDisableEnable *
Bluetooth Power Saving ModePID : 00h 06hSize : 00h 01h (1 Byte)- 00h- 01hDisable *Enable
Variable PIN CodePID : 00h 07hSize : 00h 01h (1 Byte)- 00h- 01hDisable *Enable

.Notes

  1. User Defined Bluetooth Device Name (F & L Series) can be set to a 16-character name, the device name should be followed by a 00h. If the device name is less than 16 characters, the rest should be set to FFh. For example, if you want to set the name to "BT-1", this parameter should be "42, 54, 2D, 31, 00, FF, FF, FF, FF, FF, FF, FF, FF, FF, FF, FF"
  2. User Defined Bluetooth PIN Code can be set to an 8-character name, the PIN Code should be followed by a 00h. If the PIN Code is less than 8 characters, the rest should be set to FFh. For example, to set PIN code to "1234", this parameter should be "31, 32, 33, 34, 00, FF, FF, FF, FF"

Parameter(s)

< Table 5-5-1 > Set Bluetooth Parameter(s) Field

Parameter / PID / Size Options Descriptions
Auto Power Off TimeoutPID : 00h 08hSize : 00h 01h (1 Byte)- 06h- 00h~0Ch(See Notes)6 (x5) minutes *User defined 0~12 (x5) minutes
Bluetooth Device Name(A Series)PID : 00h 09hSize : 00h 21h (33 Bytes)- 00h FFh... FFh(thirty-two “FFh”s)- XXh XXh...XXhDefault *User defined (See Notes)

.Notes

  1. Auto Power Off Timeout is available for A Series only.
  2. User Defined Bluetooth Device Name (A Series) can be set to a 32-character name, the device name should be followed by a 00h. If the device name is less than 32 characters, the rest should be set to FFh. For example, if you want to set the name to "BT-1", this parameter should be "42, 54, 2D, 31, 00, FF, FF, FF, FF, FF, FF, FF, FF, FF, FF, FF, FF, FF, FF, FF, FF, FF, FF, FF, FF, FF, FF, FF, FF, FF, FF, FF, FF, FF"

Command Descriptions

Get Bluetooth (BT)

Descriptions

Request the desired one or more parameters of the Bluetooth Settings

Available for F, L & A series

Packet Format

PrefixOpcodeStatusLengthParameter(s)LRCSuffix
7EhD9h00h00hVariableSee BelowVariable7Eh
1 Byte3Bytes1 Byte2 BytesVariable1 Byte1 Byte
Parameter(s)
First Parameter......Last Parameter
PID Size ......PID Size
2 Bytes2 Bytes......2 Bytes2 Bytes
See Next Page

. Host Requirements

If the device successfully received the above command issued by the host, the device will pack all requested parameters into a "Reply Bluetooth" message string then send to the host. Please refer to the "Reply Bluetooth" command for details. Otherwise, a "Device NAK" will be sent to host to indicate issue a command error. However, if the host can receive any response from the device within the user preset time-out duration, please resend the above command.

. Parameter(s) Field

Get Bluetooth can request multiple parameters at one time, so it takes compound parameters.

. Length

Total size (bytes) of the Parameter(s) field

.LRC

"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"

. Size

Total size (bytes) of the Options field

Parameter(s)

< Table 5-5-2 > Get Bluetooth Parameter(s) Field

Parameter PID Size
Bluetooth Device Name (F & L Series) 00h 00h00h00h 00h
Bluetooth PIN Code 00h 01h00h 00h
BT Authentication 00h 02h00h 00h
Sleep Timeout Control 00h 03h00h 00h
Link Supervision Timeout 00h 04h00h 00h
HID Link Quality Settings 00h 05h00h 00h
Bluetooth Power Saving Mode 00h 06h00h 00h
Variable PIN Code 00h 07h00h 00h
Auto Power Off Timeout 00h 08h00h 00h
Bluetooth Device Name (A Series)00h 09h00h 00h

Reply Bluetooth (BT)

Descriptions

Reply the desired one or more parameters of the Bluetooth Settings

Reply Bluetooth is sent by the device in response to the Get Bluetooth command. It sends the values for all the desired parameters requested in the Get Bluetooth command.

Available for F, L & A series

Packet Format

PrefixOpcodeStatusLengthParameter(s)LRCSuffix
7Eh1Ah00h00hVariableSee Below Variable7Eh
1 Byte3Bytes1 Byte2 BytesVariable1 Byte1 Byte
Parameter(s)
First Parameter......Last Parameter
PIDSizeOptions......PIDSizeOptions
2 Bytes2 BytesVariable......2 Bytes2 BytesVariable
See Next Page

. Host Requirements

If the device successfully received the above command issued by the host, a "Device ACK" will send to the host right after the device performed the action. Otherwise, a "Device NAK" will be sent to host to issue a command error. However, if the host can not receive any response from the device within the user preset time-out duration, please resend the above command.

. Parameter(s) Field

Set USB COM can change multiple parameters at one time, so it takes compound parameters.

. Length

Total size (bytes) of the Parameter(s) field

.LRC

"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"

. Size

Total size (bytes) of the Options field

Parameter(s)

< Table 5-5-3 > Reply Bluetooth Parameter(s) Field

Parameter / PID / Size Options Descriptions
Bluetooth Device Name(F & L Series)PID : 00h 00hSize : 00h 11h (17 Bytes)- 00h FFh... FFh(sixteen “FFh”s)- XXh XXh...XXhDefault * (For example: F680BT-012E)User defined(See Notes)
Bluetooth PIN CodePID : 00h 01hSize : 00h 09h (9 Bytes)- 30h...30h 00h(eight “30h”s)- XXh XXh...XXhDefaults to “00000000”User defined(See Notes)
BT AuthenticationPID : 00h 02hSize : 00h 01h (1 Byte)- 00h- 01hDisableEnable *
Sleep Timeout ControlPID : 00h 03hSize : 00h 02h (2 Bytes) 1^st Byte- 00h- 06h- XXh 2^nd Byte- 00h- 01h- XXhSleep Timeout of Connect StateNever enter sleep mode6 (x5) minutes *User defined 0~99 (x5) minutesSleep Timeout of Disconnect StateNever enter sleep mode1 minute *User defined 0~99 minutes
Link Supervision TimeoutPID : 00h 04hSize : 00h 01h (1 Byte)- 00h- 01h- 02h- 03h- 04h1 s3 s *5 s7 s9 s
HID Link Quality SettingPID : 00h 05hSize : 00h 01h (1 Byte)- 00h- 01hDisableEnable *
Bluetooth Power Saving ModePID : 00h 06hSize : 00h 01h (1 Byte)- 00h- 01hDisable *Enable
Variable PIN CodePID : 00h 07hSize : 00h 01h (1 Byte)- 00h- 01hDisable *Enable

.Notes

  1. User Defined Bluetooth Device Name is a maximum 16-character name, which is followed by a 00h. If the device name is less than 16 characters, the rest should be set to FFh. For example, if the name is "BT-1", this parameter should be "42, 54, 2D, 31, 00, FF, FF, FF, FF, FF, FF, FF, FF, FF, FF, FF, FF"
  2. User Defined Bluetooth PIN Code is a maximum 8-character name, the PIN Code is followed by a 00h. If the PIN Code is less than 8 characters, the rest is filled with FFh. For example, if the PIN code is "1234", this parameter should be "31, 32, 33, 34, 00, FF, FF, FF, FF"

Parameter(s)

< Table 5-5-3 > Reply Bluetooth Parameter(s) Field

Parameter / PID / Size Options Descriptions
Auto Power Off TimeoutPID : 00h 08hSize : 00h 01h (1 Byte)- 06h- 00h~0Ch(See Notes)6 (x5) minutes *User defined 0~12 (x5) minutes
Bluetooth Device Name(A Series)PID : 00h 09hSize : 00h 21h (33 Bytes)- 00h FFh... FFh(thirty-two “FFh”s)- XXh XXh...XXhDefault *User defined(See Notes)

Notes

  1. Auto Power Off Timeout is available for A Series only.
  2. User Defined Bluetooth Device Name (A Series) can be set to a 32-character name, the device name should be followed by a 00h. If the device name is less than 32 characters, the rest should be set to FFh. For example, if you want to set the name to "BT-1", this parameter should be "42, 54, 2D, 31, 00, FF, FF, FF, FF, FF, FF, FF, FF, FF, FF, FF, FF, FF, FF, FF, FF, FF, FF, FF, FF, FF, FF, FF, FF, FF, FF, FF, FF, FF, FF"

Command Descriptions

Set USB HID (WF)

Descriptions

Change the desired one or more parameters of the USB HID Interface settings

Available for F & L series

Packet Format

PrefixOpcodeStatusLengthParameter(s)LRCSuffix
7Eh82h00h02h00hVariableSee BelowVariable7Eh
1 Byte3Bytes1 Byte2 Bytes/Variable1 Byte
Parameter(s)
First Parameter......Last Parameter
PIDSizeOptions......PIDSizeOptions
2 Bytes2 BytesVariable......2 Bytes2 BytesVariable
See Next Page

. Host Requirements

If the device successfully received the above command issued by the host, a "Device ACK" will send to the host right after the device performed the action. Otherwise, a "Device NAK" will be sent to host to issue a command error. However, if the host can not receive any response from the device within the user preset time-out duration, please resend the above command.

. Parameter(s) Field

Set USB HID command can change multiple parameters at one time, so it takes compound parameters.

. Length

Total size (bytes) of the Parameter(s) field

.LRC

"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"

. Size

Total size (bytes) of the Options field

Parameter(s)

< Table 5-6-1 > Set USB HID Parameter(s) Field

Parameter / PID / Size Options Descriptions
Keyboard LayoutPID : 00h 01hSize : 00h 01h (1 Byte)- 00h- 03h- 04h- 07h- 0Bh- 0Ah- 02h- 0Ch- 09h- 0Dh- 05h- 0Eh- 08h- 01h- 06h- 0Fh- 10h- 11h- 62hUSA (QWERTY) *France (AZERTY)Germany (QWERTZ)United Kingdom – UK (QWERTY)Canadian French (QWERTY)Spain (Spanish, QWERTY)Sweden/Finland (QWERTY)Portugal (QWERTY)Norway (QWERTY)Spain (Latin America, QWERTY)Italy (QWERTY)Netherlands (QWERTY)Denmark (QWERTY)BelgiumSwitzerland – Germany (QWERTY)Iceland (QWERTY)Japan (DOS/V)Czech (QWERTY)Universal
Caps Lock ReleasePID : 00h 02hSize : 00h 01h (1 Byte)- 00h- 01h“Caps Lock On, Caps Off”“Caps Lock On, Shift Off”
Caps LockPID : 00h 03hSize : 00h 01h (1 Byte)- 00h- 01h- 06h“Caps Lock Off” State “Caps Lock On” StateAuto Detect
Function Key EmulationPID : 00h 04hSize : 00h 01h (1 Byte)- 00h- 01hEnable ASCII 00-31 code as keyboard function code *Ctrl-Output
Key Pad EmulationPID : 00h 05hSize : 00h 01h (1 Byte)- 00h- 01hDisable *Enable
Upper/Lower CasePID : 00h 06hSize : 00h 01h (1 Byte)- 00h- 01h- 02h- 03hNormal case *Inverse caseUpper caseLower case

Get USB HID (WF)

Descriptions

Request the desired one or more parameters of the USB HID Interface settings Available for F & L series

Packet Format

PrefixOpcodeStatusLengthParameter(s)LRCSuffix
7EhC3h 00h 02h00hVariableSee Below Variable7Eh
1 Byte3Bytes1 Byte2 BytesVariable1 Byte1 Byte
Parameter(s)
First Parameter......Last Parameter
PID Size ......PID Size
2 Bytes2 Bytes......2 Bytes2 Bytes
See Next Page

. Host Requirements

If the device successfully received the above command issued by the host, the device will pack all requested parameters into a "Reply USB HID" message string then send to the host. Please refer to the "Reply USB HID" command for details. Otherwise, a "Device NAK" will be sent to host to indicate issue a command error. However, if the host can receive any response from the device within the user preset time-out duration, please resend the above command.

. Parameter(s) Field

Get USB HID command can request multiple parameters at one time, so it takes compound parameters.

. Length

Total size (bytes) of the Parameter(s) field

.LRC

"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"

. Size

Total size (bytes) of the Options field

Parameter(s)

< Table 5-6-2 > Get USB HID Parameter(s) Field

Parameter PID Size
Keyboard Layout 00h 01h00h 00h
Caps Lock Release 00h 02h00h 00h
Caps Lock 00h 03h00h 00h
Function Key Emulation 00h 04h00h 00h
Key Pad Emulation 00h 05h00h 00h
Upper/Lower Case 00h 06h00h 00h

Reply USB HID (WF)

Descriptions

Reply USB HID Interface Settings

Reply USB HID is sent by the device in response to the Get USB HID command. It sends the values for all the desired parameters requested in the Get USB HID command.

Available for F & L series

Packet Format

PrefixOpcodeStatusLengthParameter(s)LRCSuffix
7Eh04h00h02h00hVariableSee BelowVariable7Eh
1 Byte3Bytes1 Byte2 BytesVariable1 Byte1 Byte
Parameter(s)
First Parameter ......Last Parameter
PIDSizeOptions......PIDSizeOptions
2 Bytes2 BytesVariable......2 Bytes2 BytesVariable
See Next Page

. Host Requirements

Since Reply USB HID is a device-to-host message, there is no response for this message.

. Parameter(s) Field

Set USB HID command can change multiple parameters at one time, so it takes compound parameters.

. Length

Total size (bytes) of the Parameter(s) field

.LRC

"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"

. Size

Total size (bytes) of the Options field

Parameter(s)

< Table 5-6-3 > Reply USB HID Parameter(s) Field

Parameter / PID / Size Options Descriptions
Keyboard LayoutPID : 00h 01hSize : 00h 01h (1 Byte)- 00h- 03h- 04h- 07h- 0Bh- 0Ah- 02h- 0Ch- 09h- 0Dh- 05h- 0Eh- 08h- 01h- 06h- 0Fh- 10h- 11h- 62hUSA (QWERTY) *France (AZERTY)Germany (QWERTZ)United Kingdom – UK (QWERTY)Canadian French (QWERTY)Spain (Spanish, QWERTY)Sweden/Finland (QWERTY)Portugal (QWERTY)Norway (QWERTY)Spain (Latin America, QWERTY)Italy (QWERTY)Netherlands (QWERTY)Denmark (QWERTY)BelgiumSwitzerland – Germany (QWERTY)Iceland (QWERTY)Japan (DOS/V)Czech (QWERTY)Universal
Caps Lock ReleasePID : 00h 02hSize : 00h 01h (1 Byte)- 00h- 01h“Caps Lock On, Caps Off”“Caps Lock On, Shift Off”
Caps LockPID : 00h 03hSize : 00h 01h (1 Byte)- 00h- 01h- 06h“Caps Lock Off” State “Caps Lock On” StateAuto Detect
Function Key EmulationPID : 00h 04hSize : 00h 01h (1 Byte)- 00h- 01hEnable ASCII 00-31 code as keyboard function code *Ctrl-Output
Key Pad EmulationPID : 00h 05hSize : 00h 01h (1 Byte)- 00h- 01hDisable *Enable
Upper/Lower CasePID : 00h 06hSize : 00h 01h (1 Byte)- 00h- 01h- 02h- 03hNormal case *Inverse caseUpper caseLower case

Set USB COM (WF)

Descriptions

Change the desired one or more parameters of the USB COM Interface settings Available for F & L series

Packet Format

PrefixOpcodeStatusLengthParameter(s)LRCSuffix
7Eh82h00h03h00hVariableSee BelowVariable7Eh
1 Byte3Bytes1 Byte2 BytesVariable1 Byte1 Byte
Parameter(s)
First Parameter......Last Parameter
PIDSizeOptions......PIDSizeOptions
2 Bytes2 BytesVariable......2 Bytes2 BytesVariable
See Next Page

. Host Requirements

If the device successfully received the above command issued by the host, a "Device ACK" will send to the host right after the device performed the action. Otherwise, a "Device NAK" will be sent to host to issue a command error. However, if the host can not receive any response from the device within the user preset time-out duration, please resend the above command.

. Parameter(s) Field

Set USB COM can change multiple parameters at one time, so it takes compound parameters.

. Length

Total size (bytes) of the Parameter(s) field

.LRC

"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"

. Size

Total size (bytes) of the Options field

Parameter(s)

< Table 5-7-1 > Set USB COM Parameter(s) Field

Parameter / PID / Size Options Descriptions
STX/ETX TransmissionPID : 00h 00hSize : 00h 01h (1 Byte)- 00h- 01hDisable *Enable
Baud RatePID : 00h 02hSize : 00h 01h (1 Byte)- 02h- 03h- 04h- 05h- 06h- 07h- 08h- 09h1200 BPS2400 BPS4800 BPS9600 BPS *19200 BPS38400 BPS57600 BPS115200 BPS
Data Frame(Data Bit, Parity, Stop Bit )PID : 00 03Size : 00h 01h (1 Byte)- 02h- 08h- 05h- 0Ah- 0Bh- 09h- 06h- 03h- 0Ch- 0Dh- 01h- 07h- 04h- 0Eh- 0Fh8, None, 1 *8, Odd, 18, Even, 18, Space, 18, Mark, 18, None, 27, Odd, 17, Even, 17, Space, 17, Mark, 17, None, 27, Odd, 27, Even, 27, Space, 27, Mark, 2

Get USB COM (WF)

Descriptions

Request the desired one or more parameters of the USB COM Interface settings Available for F & L series

Packet Format

PrefixOpcodeStatusLengthParameter(s)LRCSuffix
7EhC3h00h03h00hVariableSee Below Variable7Eh
1 Byte3Bytes1 Byte2 BytesVariable1 Byte1 Byte
Parameter(s)
First Parameter......Last Parameter
PID Size ......PID Size
2 Bytes2 Bytes......2 Bytes2 Bytes
See Next Page

. Host Requirements

If the device successfully received the above command issued by the host, the device will pack all requested parameters into a "Reply USB COM" message string then send to the host. Please refer to the "Reply USB COM" command for details. Otherwise, a "Device NAK" will be sent to host to indicate issue a command error. However, if the host can receive any response from the device within the user preset time-out duration, please resend the above command.

. Parameter(s) Field

Get USB COM can request multiple parameters at one time, so it takes compound parameters.

. Length

Total size (bytes) of the Parameter(s) field

.LRC

"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"

. Size

Total size (bytes) of the Options field

Parameter(s)

< Table 5-7-2 > Get USB COM Parameter(s) Field

Parameter PID Size
STX/ETX Transmission 00h 00h00h 00h
Baud Rate 00h 02h00h 00h
Data Frame 00h 03h00h 00h

Reply USB COM (WF)

Descriptions

Reply the desired one or more parameters of the USB COM Interface settings

Reply USB COM is sent by the device in response to the Get USB COM command. It sends the values for all the desired parameters requested in the Get USB COM command.

Available for F & L series

Packet Format

PrefixOpcodeStatusLengthParameter(s)LRCSuffix
7Eh04h00h03h00hVariableSee Below Variable7Eh
1 Byte3Bytes1 Byte2 BytesVariable1 Byte1 Byte
Parameter(s)
First Parameter......Last Parameter
PIDSizeOptions......PIDSizeOptions
2 Bytes2 BytesVariable......2 Bytes2 BytesVariable
See Next Page

. Host Requirements

Since Reply USB COM is a device-to-host message, there is no response for this message.

. Parameter(s) Field

Set USB COM can change multiple parameters at one time, so it takes compound parameters.

. Length

Total size (bytes) of the Parameter(s) field

.LRC

"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"

. Size

Total size (bytes) of the Options field

Parameter(s)

< Table 5-7-3 > Reply USB COM Parameter(s) Field

Parameter / PID / Size Options Descriptions
STX/ETX TransmissionPID : 00h 00hSize : 00h 01h (1 Byte)- 00h- 01hDisable *Enable
Baud RatePID : 00h 02hSize : 00h 01h (1 Byte)- 02h- 03h- 04h- 05h- 06h- 07h- 08h- 09h1200 BPS2400 BPS4800 BPS9600 BPS *19200 BPS38400 BPS57600 BPS115200 BPS
Data Frame(Data Bit, Parity, Stop Bit )PID : 00 03Size : 00h 01h (1 Byte)- 02h- 08h- 05h- 0Ah- 0Bh- 09h- 06h- 03h- 0Ch- 0Dh- 01h- 07h- 04h- 0Eh- 0Fh8, None, 1 *8, Odd, 18, Even, 18, Space, 18, Mark, 18, None, 27, Odd, 17, Even, 17, Space, 17, Mark, 17, None, 27, Odd, 27, Even, 27, Space, 27, Mark, 2

Command Descriptions

Set Wi-Fi (WF)

Descriptions

Change the desired one or more parameters of the Wi-Fi settings

Available for F & L series

Packet Format

PrefixOpcodeStatusLengthParameter(s)LRCSuffix
7Eh9Bh00h00hVariableSee Below Variable7Eh
1 Byte3Bytes1 Byte2 Bytes/Variable1 Byte
Parameter(s)
First Parameter ......Last Parameter
PIDSizeOptions......PIDSizeOptions
2 Bytes2 BytesVariable......2 Bytes2 BytesVariable
See Next Page

. Host Requirements

If the device successfully received the above command issued by the host, a "Device ACK" will send to the host right after the device performed the action. Otherwise, a "Device NAK" will be sent to host to issue a command error. However, if the host can not receive any response from the device within the user preset time-out duration, please resend the above command.

. Parameter(s) Field

Set USB COM can change multiple parameters at one time, so it takes compound parameters.

. Length

Total size (bytes) of the Parameter(s) field

.LRC

"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"

. Size

Total size (bytes) of the Options field

Parameter(s)

< Table 5-8-1 > Set Wi-Fi Parameter(s) Field

Parameter / PID / Size Options Descriptions
Sleep Timeout ControlPID : 00h 14hSize : 00h 02h (2 Bytes) 1^st Byte- 00h- 06h- XXh 2^nd Byte- 00h- 05h- XXhSleep Timeout of Connect StateNever enter sleep mode6 (x5) minutes *User defined 0~99 (x5) minutesSleep Timeout of Disconnect StateNever enter sleep mode5 minute *User defined 0~99 minutes
Keep Alive TimeoutPID : 00h 15hSize : 00h 02h (2 Bytes) 1^st Byte- 00h- 01h- 03h- 06h 2^nd Byte- 00hKeep Alive TimeoutDisable10 seconds *30 seconds60 secondsReserved (Always Zero)
Reconnect IntervalPID : 00h 16hSize : 00h 01h (1 Byte)- 02h- XXh2 seconds *User defined 0~255 seconds
Power Saving ModePID : 00h 17hSize : 00h 01h (1 Byte)- 00h- 01hDisable *Enable
COM Port ValidationPID : 01h 00hSize : 00h 01h (1 Byte)- 00h- 01hDisable *Enable

Get Wi-Fi (WF)

Descriptions

Request the desired one or more parameters of the Wi-Fi settings Available for F & L series

Packet Format

PrefixOpcodeStatusLengthParameter(s)LRCSuffix
7EhDCh 00h 00h00hVariableSee Below Variable7Eh
1 Byte3Bytes1 Byte2 BytesVariable1 Byte1 Byte
Parameter(s)
First Parameter......Last Parameter
PID Size ......PID Size
2 Bytes2 Bytes......2 Bytes2 Bytes
See Next Page

. Host Requirements

If the device successfully received the above command issued by the host, the device will pack all requested parameters into a "Reply Wi-Fi" message string then send to the host. Please refer to the "Reply Wi-Fi" command for details. Otherwise, a "Device NAK" will be sent to host to indicate issue a command error. However, if the host can receive any response from the device within the user preset time-out duration, please resend the above command.

. Parameter(s) Field

Get USB COM can request multiple parameters at one time, so it takes compound parameters.

. Length

Total size (bytes) of the Parameter(s) field

.LRC

"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"

. Size

Total size (bytes) of the Options field

Parameter(s)

< Table 5-8-2 > Get Wi-Fi Parameter(s) Field

Parameter PID Size
Wi-Fi MAC Address 00h 0Ch00h 00h
Sleep Timeout Control 00h 14h00h 00h
Keep Alive Timeout 00h 15h00h 00h
Reconnect Interval 00h 16h00h 00h
Power Saving Mode 00h 17h00h 00h
COM Port Validation 01h 00h00h 00h

Reply Wi-Fi (WF)

Descriptions

Reply the desired one or more parameters of the Wi-Fi Interface settings

Reply Wi-Fi is sent by the device in response to the Get Wi-Fi command. It sends the values for all the desired parameters requested in the Get Wi-Fi command.

Available for F & L series

Packet Format

PrefixOpcodeStatusLengthParameter(s)LRCSuffix
7Eh1Dh00h00hVariableSee BelowVariable7Eh
1 Byte3Bytes1 Byte2 BytesVariable1 Byte1 Byte
Parameter(s)
First Parameter ......Last Parameter
PIDSizeOptions......PIDSizeOptions
2 Bytes2 BytesVariable......2 Bytes2 BytesVariable
See Next Page

. Host Requirements

Since Reply USB COM is a device-to-host message, there is no response for this message.

. Parameter(s) Field

Set USB COM can change multiple parameters at one time, so it takes compound parameters.

. Length

Total size (bytes) of the Parameter(s) field

.LRC

"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"

. Size

Total size (bytes) of the Options field

Parameter(s)

< Table 5-8-3 > Reply Wi-Fi Parameter(s) Field

Parameter / PID / Size Options Descriptions
Wi-Fi MAC AddressPID : 00h 0ChSize : 00h 06h (6 Bytes) 1^st Byte- XXh 2^nd Byte- XXh 3^rd Byte- XXh 4^th Byte- XXh 5^th Byte- XXh 6^th Byte- XXhThe 6th number of MAC AddressUser defined XXThe 5th number of MAC AddressUser defined XXThe 4th number of MAC AddressUser defined XXThe 3rd number of MAC AddressUser defined XXThe 2nd number of MAC AddressUser defined XXThe 1st number of MAC AddressUser defined XX
Sleep Timeout ControlPID : 00h 14hSize : 00h 02h (2 Bytes) 1^st Byte- 00h- 06h- XXh 2^nd Byte- 00h- 05h- XXhSleep Timeout of Connect StateNever enter sleep mode6 (x5) minutes *User defined 0~99 (x5) minutesSleep Timeout of Disconnect StateNever enter sleep mode5 minute *User defined 0~99 minutes
Keep Alive TimeoutPID : 00h 15hSize : 00h 02h (2 Bytes) 1^st Byte- 00h- 01h- 03h- 06h 2^nd Byte- 00hKeep Alive TimeoutDisable10 seconds *30 seconds60 secondsReserved (Always Zero)
Reconnect IntervalPID : 00h 16hSize : 00h 01h (1 Byte)- 02h- XXh2 seconds *User defined 0~255 seconds
Power Saving ModePID : 00h 17hSize : 00h 01h (1 Byte)- 00h- 01hDisable *Enable
COM Port ValidationPID : 01h 00hSize : 00h 01h (1 Byte)- 00h- 01hDisable *Enable

2.6 Operation

Set TS Operation (TS)

Descriptions

Change the desired one or more parameters of the Operation Settings for Tethered Scanner Available for F, L & A series

Packet Format

PrefixOpcodeStatusLengthParameter(s)LRCSuffix
7Eh88h00h00hVariableSee BelowVariable7Eh
1 Byte3Bytes1 Byte2 BytesVariable1 Byte1 Byte
Parameter(s)
First Parameter......Last Parameter
PIDSizeOptions......PIDSizeOptions
2 Bytes2 BytesVariable......2 Bytes2 BytesVariable
See Next Page

. Host Requirements

If the device successfully received the above command issued by the host, a "Device ACK" will send to the host right after the device performed the action. Otherwise, a "Device NAK" will be sent to host to issue a command error. However, if the host can not receive any response from the device within the user preset time-out duration, please resend the above command.

. Parameter(s) Field

Set TS Operation can change multiple parameters at one time, so it takes compound parameters.

. Length

Total size (bytes) of the Parameter(s) field

.LRC

"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"

. Size

Total size (bytes) of the Options field

Parameter(s)

< Table 6-1-1 > Set TS Operation Parameter(s) Field (To be continued)

Parameter / PID / Size Options Descriptions
Presentation ControlPID : 00h 01hSize : 00h 01h (1 Byte)- 01h- 02h- 08hForce modePresentation mode *Flash mode (See Notes)
Presentation Auto-sensePID : 00h 02hSize : 00h 01h (1 Byte)- 00h- 01hDisable *Enable
Presentation SensitivityPID : 00h 03hSize : 00h 01h (1 Byte)- 00h- 01h- 02h- 03h- 04h- 05h- 06hLevel 1Level 2Level 3Level 4Level 5 *Level 6Level 7
Reread DelayPID : 00h 04hSize : 00h 01h (1 Byte)- 00h- 01h- 02h- 03h- 04h- 05hDisableImmediate time-out duration *Short time-out durationMedium time-out durationLong time out-durationForce Verification
Flash Duty CyclePID : 00h 05hSize : 00h 01h (1 Byte)- 00h- 01h- 02h- 03h1/2 duty cycle * (See Notes)2/3 duty cycle3/4 duty cycle4/5 duty cycle
Good Read DelayPID : 00h 06hSize : 00h 01h (1 Byte)- 00h- 01h- 02h- 03h- 04h- 05h- 06hNone*200 ms500 ms1 s1.5 s2 s3 s
Light Source On TimePID : 00h 07hSize : 00h 01h (1 Byte)- 00h- 01h- 02h- 03hShort (about 2 s) *Medium (about 3~4 s)Long (about 5~6 s)Extremely Long (about 7~8 s)
Hands Free Time-outPID : 00h 08hSize : 00h 01h (1 Byte)- 00h- 06h- 0Ah- 0Eh- 12hDisableShort *MediumLongExtremely long
Time Delay To Low Power ModePID : 00h 09hSize : 00h 01h (1 Byte)- 00h- 01h- 02h- 03h- 04h- 05h1 s3 s5 s7 s9 s0 s (Immediately)*

. Notes

Flash mode is not available for A Series.

Parameter(s)

< Table 6-1-1 > Set TS Operation Parameter(s) Field (Continued)

Parameter / PID / Size Options Descriptions
Trigger Control(F460/468 only)PID: 00h 0AhSize: 00h 01h (2 Bytes)- 00h- 01h- 02hEnable left trigger, disable right triggerEnable right trigger, disable left triggerEnable left and right trigger *
Scan Rate ControlPID: 00h 0BhSize: 00h 01h (1 Byte)- 00h- 01hDynamic *Fixed
Buzzer Tone AdjustPID: 01h 00hSize: 00h 02h (2 Bytes) 1^st 2^nd Byte- 00h 00h- 01h 01h- 01h 02h- 01h 03h- 01h 04hMuteLowMedium *HighExtremely High
Power on beepPID: 01h 01hSize: 00h 01h (1 Byte)- 00h- 01hEnableDisable
Power on IndicationPID: 01h 02hSize: 00h 01h (1 Byte)- 00h- 01h- 02hLED offLED steady on *LED flash
VibratorPID: 01h 03hSize: 00h 01h (1 Byte)- 00h- 01hDisableEnable *
Good Read DurationPID: 01h 04hSize: 00h 01h (1 Byte)- 00h- 01h- 02h- 03h- 04hShortMedium *LongExtremely longExtremely short
Good Read IndicatorPID: 01h 05hSize: 00h 01h (1 Byte)- 00h- 01h(See Notes)DisableEnable *
1D Barcode Inverse ReadingPID: 02h 00hSize: 00h 01h (1 Byte)- 00h- 01hDisable *Enable
Dollar Sign ControlPID: 02h 01hSize: 00h 01h (1 Byte)- 00h- 80h- A2h- A3h- A5hOutput as “$” *Output as “€” Output as “¢”Output as “£” Output as “¥”
RedundancyPID: 02h 02hSize: 00h 01h (1 Byte)- 00h- 01h- 02h- 03h- 04h- 05hNone1 time *2 times3 times4 times5 times

Notes

Good Read Indicator: If enabled, the Green LED flashes once after a good decode.

Parameter(s)

< Table 6-1-1 > Set TS Operation Parameter(s) Field (Continued)

Parameter / PID / Size Options Descriptions
Data Transmission PacketPID: 02h 04hSize: 00h 01h (1 Byte)- 00h- 01hDisable *Enable
UPC/EAN Security LevelPID: 02h 06hSize: 00h 01h (1 Byte)- 00h- 01h- 02hLevel 0Level 1 *Level 2
Supplement Scan VotingPID: 02h 08hSize: 00h 01h (1 Byte)- 00h- 06h- 08h- 0Ah- 0Ch- 0Eh- 10h- 12h- 14h- 16h- 18h- 1Ah- 1Ch- 1EhNoneLevel 1Level 2Level 3 *Level 4Level 5Level 6Level 7Level 8Level 9Level 10Level 11Level 12Level 13
Laser Aiming ControlPID: 02h 09hSize: 00h 01h (1 Byte)- 00h- 01h(See Notes)DisableEnable *
LED IlluminationPID: 02h 0BhSize: 00h 01h (1 Byte)- 00h- 01h(See Notes)Always onIntelligent Scanning *
Illumination Delay DurationPID: 02h 0ChSize: 00h 01h (1 Byte)- 00h- 01h- 02h- 03h- 04h(See Notes)100ms200ms300ms400ms500ms
Operation Mode(Tethered Scanner)PID: 10h 00hSize: 00h 01h (1 Byte)- 00h- 01h- 02h- 04h- 05h- 06h- 07h- 08h- 09h(See Notes)Trigger mode (External triggering) *Force mode (Continued power on)Presentation mode (Auto detection)Level mode (Auto power off)Diagnostic mode (Test reading)Alternative mode (Periodic power off)Toggle mode (Repeat reading)Flash mode (Pulse driven reading)Low Power mode (Low Power triggering)

.Notes

  1. LED Illumination, Illumination Delay Duration are only available for L680, L688, L780, L788
  2. Laser Aiming Control is only available for L688, L788

Parameter(s)

< Table 6-1-1 > Set TS Operation Parameter(s) Field (Continued)

Parameter / PID / Size Options Descriptions
Operation Mode(Tethered A Series)PID : 70h 00hSize : 00h 03h (3 Bytes)- 00h 01h 01h- 01h 01h 01h- 02h 01h 01h- 04h 01h 00h- 05h 01h 01h- 06h 01h 00h- 07h 01h 00h- 09h 01h 01h- 0Dh 01h 01hTrigger mode *Force modePresentation modeLevel modeDiagnostic modeAlternative modeToggle modeLow Power modeMultiple mode
Hand-Held Mode Illumination & Aiming ControlPID : 70h 01hSize : 00h 01h (1 Byte)Bit 0- 0- 1Bit 1- 0- 1Hand-Held Decode Aiming ControlDisableEnable *Hand-Held Illumination ControlDisableEnable *
Hand-Free Mode DecodeAiming ControlPID : 70h 02hSize : 00h 01h (1 Byte)- 02h- 03hDisableEnable *
Aiming ControlPID : 70h 03hSize : 00h 02h (2 Bytes)- 00h 00h- 01h 00h- 00h 03hRegular AimingIntelligent Aiming *Delay Aiming Control
Delay Aiming TimeoutControlPID : 70h 04hSize : 00h 01h (1 Byte)- 02h- 04h- 08h- 0Ah- 0Fh- 14h- 1Eh- 28h200ms400ms *800ms1000ms1500ms2000ms3000ms4000ms
Presentation BackgroundLightingPID : 70h 05hSize : 00h 02h (2 Bytes)- 00h 00h- 00h FFhLEDs OffLEDs On *
Center AlignmentPID : 70h 06hSize : 00h 02h (2 Bytes)1st Byte- 00h- 01h2nd Byte- 00h- 01hHand-Held ModeDisable *EnableHand-Free ModeDisable *Enable

Parameter(s)

< Table 6-1-1 > Set TS Operation Parameter(s) Field (Continued)

Parameter / PID / Size Options Descriptions
Mobile Phone CapturePID : 70h 07hSize : 00h 01h (1 Byte)- 00h- 01hDisable *Enable
Unique Barcode ReportingPID : 70h 08hSize : 00h 01h (1 Byte)- 00h- 01hDisable *Enable

Get TS Operation (TS)

Descriptions

Request the desired one or more parameters of the Operation Settings for Tethered Scanner Available for F, L & A series

Packet Format

PrefixOpcodeStatusLengthParameter(s)LRCSuffix
7EhC9h 00h 00h00hVariableSee Below Variable7Eh
1 Byte3Bytes1 Byte2 BytesVariable1 Byte1 Byte
Parameter(s)
First Parameter......Last Parameter
PID Size ......PID Size
2 Bytes2 Bytes......2 Bytes2 Bytes
See Next Page

. Host Requirements

If the device successfully received the above command issued by the host, the device will pack all requested parameters into a "Reply TS Operation" message string then send to the host. Please refer to the "Reply TS Operation" command for details. Otherwise, a "Device NAK" will be sent to host to indicate issue a command error. However, if the host can receive any response from the device within the user preset time-out duration, please resend the above command.

. Parameter(s) Field

Get TS Operation can request multiple parameters at one time, so it takes compound parameters.

. Length

Total size (bytes) of the Parameter(s) field

.LRC

"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"

. Size

Total size (bytes) of the Options field

Parameter(s)

< Table 6-1-2 > Get TS Operation Parameter(s) Field

Parameter PID Size
Presentation Control 00h 01h00h 00h
Presentation Auto-sense 00h 02h00h 00h
Presentation Sensitivity 00h 03h00h 00h
Reread Delay 00h 04h00h 00h
Flash Duty Cycle 00h 05h00h 00h
Good Read Delay 00h 06h00h 00h
Light Source On Time 00h 07h00h 00h
Hands Free Time-out 00h 08h00h 00h
Time Delay To Low Power Mode 00h 09h00h 00h
Trigger Control00h 0Ah00h 00h
Scan Rate Control00h 0Bh00h 00h
Buzzer Tone Adjust01h 00h00h 00h
Power on beep01h 01h00h 00h
Power on Indication01h 02h00h 00h
Vibrator01h 03h00h 00h
Good Read Duration01h 04h00h 00h
Good Read Indicator 01h 05h00h 00h
1D Barcode Inverse Reading02h 00h00h 00h
Dollar Sign Control02h 01h00h 00h
Redundancy02h 02h00h 00h
Data Transmission Packet02h 04h00h 00h
UPC/EAN Security Level02h 06h00h 00h
Supplement Scan Voting 02h 08h00h 00h
Laser Aiming Control02h 09h00h 00h
LED Illumination02h 0Bh00h 00h
Illumination Delay Duration02h 0Ch00h 00h
Operation Mode (Tethered Scanner)10h 00h00h 00h
Operation Mode (Tethered A Series)70h 00h00h 00h
Hand-Held Mode Illumination & Aiming Control70h 01h00h 00h
Hand-Free Mode Decode Aiming Control70h 02h00h 00h
Aiming Control70h 03h00h 00h
Delay Aiming Timeout70h 04h00h 00h
Presentation Background Lighting70h 05h00h 00h
Center Alignment 70h 06h00h 00h
Mobile Phone Capture70h 07h00h 00h
Unique Barcode Reporting70h 08h00h 00h

Reply TS Operation (TS)

Descriptions

Reply the desired one or more parameters of the Operation Settings for Tethered Scanner Reply TS Operation is sent by the device in response to the Get TS Operation command. It sends the values for all the desired parameters requested in the Get TS Operation command. Available for F, L & A series

Packet Format

PrefixOpcodeStatusLengthParameter(s)LRCSuffix
7Eh0Ah00h 00h00hVariableSee Below Variable7Eh
1 Byte3Bytes1 Byte2 BytesVariable1 Byte1 Byte
Parameter(s)
First Parameter......Last Parameter
PIDSizeOptions......PIDSizeOptions
2 Bytes2 BytesVariable......2 Bytes2 BytesVariable
See Next Page
Parameter(s)
First Parameter......Last Parameter
PIDSizeOptions......PIDSizeOptions
2 Bytes2 BytesVariable......2 Bytes2 BytesVariable
See Next Page

. Host Requirements

Since Reply TS Operation is a device-to-host message, there is no response for this message.

. Parameter(s) Field

Set TS Operation can change multiple parameters at one time, so it takes compound parameters.

. Length

Total size (bytes) of the Parameter(s) field

.LRC

"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"

. Size

Total size (bytes) of the Options field

Parameter(s)

< Table 6-1-3 > Reply TS Operation Parameter(s) Field (To be continued)

Parameter / PID / Size Options Descriptions
Presentation ControlPID : 00h 01hSize : 00h 01h (1 Byte)- 01h- 02h- 08hForce modePresentation mode *Flash mode (See Notes)
Presentation Auto-sensePID : 00h 02hSize : 00h 01h (1 Byte)- 00h- 01hDisable *Enable
Presentation SensitivityPID : 00h 03hSize : 00h 01h (1 Byte)- 00h- 01h- 02h- 03h- 04h- 05h- 06hLevel 1Level 2Level 3Level 4Level 5 *Level 6Level 7
Reread DelayPID : 00h 04hSize : 00h 01h (1 Byte)- 00h- 01h- 02h- 03h- 04h- 05hDisableImmediate time-out duration *Short time-out durationMedium time-out durationLong time out-durationForce Verification
Flash Duty CyclePID : 00h 05hSize : 00h 01h (1 Byte)- 00h- 01h- 02h- 03h1/2 duty cycle * (See Notes)2/3 duty cycle3/4 duty cycle4/5 duty cycle
Good Read DelayPID : 00h 06hSize : 00h 01h (1 Byte)- 00h- 01h- 02h- 03h- 04h- 05h- 06hNone*200 ms500 ms1 s1.5 s2 s3 s
Light Source On TimePID : 00h 07hSize : 00h 01h (1 Byte)- 00h- 01h- 02h- 03hShort (about 2 s) *Medium (about 3~4 s)Long (about 5~6 s)Extremely Long (about 7~8 s)
Hands Free Time-outPID : 00h 08hSize : 00h 01h (1 Byte)- 00h- 06h- 0Ah- 0Eh- 12hDisableShort *MediumLongExtremely long
Time Delay To Low Power ModePID : 00h 09hSize : 00h 01h (1 Byte)- 00h- 01h- 02h- 03h- 04h- 05h1 s3 s5 s7 s9 s0 s (Immediately)*

. Notes

Flash mode is not available for A Series.

Parameter(s)

< Table 6-1-3 > Reply TS Operation Parameter(s) Field (Continued)

Parameter / PID / Size Options Descriptions
Trigger Control(F460/468 only)PID: 00h 0AhSize: 00h 01h (2 Bytes)- 00h- 01h- 02hEnable left trigger, disable right triggerEnable right trigger, disable left triggerEnable left and right trigger *
Scan Rate ControlPID: 00h 0BhSize: 00h 01h (1 Byte)- 00h- 01hDynamic *Fixed
Buzzer Tone AdjustPID: 01h 00hSize: 00h 02h (2 Bytes) 1^st 2^nd Byte- 00h 00h- 01h 01h- 01h 02h- 01h 03h- 01h 04hMuteLowMedium *HighExtremely High
Power on beepPID: 01h 01hSize: 00h 01h (1 Byte)- 00h- 01hEnableDisable
Power on IndicationPID: 01h 02hSize: 00h 01h (1 Byte)- 00h- 01h- 02hLED offLED steady on *LED flash
VibratorPID: 01h 03hSize: 00h 01h (1 Byte)- 00h- 01hDisableEnable *
Good Read DurationPID: 01h 04hSize: 00h 01h (1 Byte)- 00h- 01h- 02h- 03h- 04hShortMedium *LongExtremely longExtremely short
Good Read IndicatorPID: 01h 05hSize: 00h 01h (1 Byte)- 00h- 01h(See Notes)DisableEnable *
1D Barcode Inverse ReadingPID: 02h 00hSize: 00h 01h (1 Byte)- 00h- 01hDisable *Enable
Dollar Sign ControlPID: 02h 01hSize: 00h 01h (1 Byte)- 00h- 80h- A2h- A3h- A5hOutput as “$” *Output as “€” Output as “¢”Output as “£” Output as “¥”
RedundancyPID: 02h 02hSize: 00h 01h (1 Byte)- 00h- 01h- 02h- 03h- 04h- 05hNone1 time *2 times3 times4 times5 times

Notes

Good Read Indicator: If enabled, the Green LED flashes once after a good decode.

Parameter(s)

< Table 6-1-3 > Reply TS Operation Parameter(s) Field (Continued)

Parameter / PID / Size Options Descriptions
Data Transmission PacketPID: 02h 04hSize: 00h 01h (1 Byte)- 00h- 01hDisable *Enable
UPC/EAN Security LevelPID: 02h 06hSize: 00h 01h (1 Byte)- 00h- 01h- 02hLevel 0Level 1 *Level 2
Supplement Scan VotingPID: 02h 08hSize: 00h 01h (1 Byte)- 00h- 06h- 08h- 0Ah- 0Ch- 0Eh- 10h- 12h- 14h- 16h- 18h- 1Ah- 1Ch- 1EhNoneLevel 1Level 2Level 3 *Level 4Level 5Level 6Level 7Level 8Level 9Level 10Level 11Level 12Level 13
Laser Aiming ControlPID: 02h 09hSize: 00h 01h (1 Byte)- 00h- 01h(See Notes)DisableEnable *
LED IlluminationPID: 02h 0BhSize: 00h 01h (1 Byte)- 00h- 01h(See Notes)Always onIntelligent Scanning *
Illumination Delay DurationPID: 02h 0ChSize: 00h 01h (1 Byte)- 00h- 01h- 02h- 03h- 04h(See Notes)100ms200ms300ms400ms500ms
Operation Mode(Tethered Scanner)PID: 10h 00hSize: 00h 01h (1 Byte)- 00h- 01h- 02h- 04h- 05h- 06h- 07h- 08h- 09hTrigger mode (External triggering) *Force mode (Continued power on)Presentation mode (Auto detection)Level mode (Auto power off)Diagnostic mode (Test reading)Alternative mode (Periodic power off)Toggle mode (Repeat reading)Flash mode (Pulse driven reading)Low Power mode (Low Power triggering)

.Notes

  1. LED Illumination, Illumination Delay Duration are only available for L680, L688, L780, L788
  2. Laser Aiming Control is only available for L688, L788

Parameter(s)

< Table 6-1-3 > Reply TS Operation Parameter(s) Field (Continued)

Parameter / PID / Size Options Descriptions
Operation Mode(Tethered A Series)PID : 70h 00hSize : 00h 03h (3 Bytes)- 00h 01h 01h- 01h 01h 01h- 02h 01h 01h- 04h 01h 00h- 05h 01h 01h- 06h 01h 00h- 07h 01h 00h- 09h 01h 01h- 0Dh 01h 01hTrigger mode *Force modePresentation modeLevel modeDiagnostic modeAlternative modeToggle modeLow Power modeMultiple mode
Hand-Held Mode Illumination & Aiming ControlPID : 70h 01hSize : 00h 01h (1 Byte)Bit 0- 0- 1Bit 1- 0- 1Hand-Held Decode Aiming ControlDisableEnable *Hand-Held Illumination ControlDisableEnable *
Hand-Free Mode DecodeAiming ControlPID : 70h 02hSize : 00h 01h (1 Byte)- 02h- 03hDisableEnable *
Aiming ControlPID : 70h 03hSize : 00h 02h (2 Bytes)- 00h 00h- 01h 00h- 00h 03hRegular AimingIntelligent Aiming *Delay Aiming Control
Delay Aiming TimeoutControlPID : 70h 04hSize : 00h 01h (1 Byte)- 02h- 04h- 08h- 0Ah- 0Fh- 14h- 1Eh- 28h200ms400ms *800ms1000ms1500ms2000ms3000ms4000ms
Presentation BackgroundLightingPID : 70h 05hSize : 00h 02h (2 Bytes)- 00h 00h- 00h FFhLEDs OffLEDs On *
Center AlignmentPID : 70h 06hSize : 00h 02h (2 Bytes)1st Byte- 00h- 01h2nd Byte- 00h- 01hHand-Held ModeDisable *EnableHand-Free ModeDisable *Enable

Parameter(s)

< Table 6-1-3 > Reply TS Operation Parameter(s) Field (Continued)

Parameter / PID / Size Options Descriptions
Mobile Phone CapturePID : 70h 07hSize : 00h 01h (1 Byte)- 00h- 01hDisable *Enable
Unique Barcode ReportingPID : 70h 08hSize : 00h 01h (1 Byte)- 00h- 01hDisable *Enable

Set SE Operation (SE)

Descriptions

Change the desired one or more parameters of the Operation Settings for Scan Engine

Available for SE380, SE390 & SE480 series

Packet Format

PrefixOpcodeStatusLengthParameter(s)LRCSuffix
7Eh88h00h00hVariableSee Below Variable7Eh
1 Byte3Bytes1 Byte2 Bytes/Variable1 Byte 1 Byte
Parameter(s)
First Parameter ......Last Parameter
PIDSizeOptions......PIDSizeOptions
2 Bytes2 BytesVariable......2 Bytes2 BytesVariable
See Next Page

. Host Requirements

If the device successfully received the above command issued by the host, a "Device ACK" will send to the host right after the device performed the action. Otherwise, a "Device NAK" will be sent to host to issue a command error. However, if the host can not receive any response from the device within the user preset time-out duration, please resend the above command.

. Parameter(s) Field

Set SE Operation can change multiple parameters at one time, so it takes compound parameters.

. Length

Total size (bytes) of the Parameter(s) field

.LRC

"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"

. Size

Total size (bytes) of the Options field

Parameter(s)

< Table 6-2-1 > Set SE Operation Parameter(s) Field (To be continued)

Parameter / PID / Size Options Descriptions
Presentation SensitivityPID : 00h 03hSize : 00h 01h (1 Byte)- 00h- 01h- 02h- 03h- 04h- 05h- 06hLevel 1Level 2Level 3Level 4Level 5 *Level 6Level 7
Reread DelayPID : 00h 04hSize : 00h 01h (1 Byte)- 00h- 01h- 02h- 03h- 04h- 05hDisableImmediate time-out duration *Short time-out durationMedium time-out durationLong time out-durationForce Verification
Good Read DelayPID : 00h 06hSize : 00h 01h (1 Byte)- 00h- 01h- 02h- 03h- 04h- 05h- 06hNone*200 ms500 ms1 s1.5 s2 s3 s
Scan Input Time-outPID : 00h 07hSize : 00h 01h (1 Byte)- 00h- 01h- 02h- 03h- 04h- 05h- 06h- 07h- 08h- XXh100ms200ms300ms400ms500ms600ms700ms800ms900ms *User-defined 1-99 s:XXh = desiredseconds(h) + 80h
Hands Free Time-outPID : 00h 08hSize : 00h 01h (1 Byte)- 00h- 06h- 0Ah- 0Eh- 12hDisableShort *MediumLongExtremely long
Time Delay To Low Power ModePID : 00h 09hSize : 00h 01h (1 Byte)- 00h- 01h- 02h- 03h- 04h- 05h1 s3 s5 s7 s9 s0 s (Immediately)*
Scan Rate ControlPID : 00h 0BhSize : 00h 01h (1 Byte)- 00h- 01hDynamic *Fixed
Buzzer Tone AdjustPID : 01h 00hSize : 00h 02h (2 Bytes) 1^st 2^nd Byte- 00h 00h- 01h 01h- 01h 02h- 01h 03h- 01h 04hMuteLowMedium *HighExtremely High
Power on beepPID : 01h 01hSize : 00h 01h (1 Byte)- 00h- 01hEnable (SE380/SE388-9 *)Disable (SE380/SE388-0, SE380/SE388-1 *)

Parameter(s)

< Table 6-2-1 > Set SE Operation Parameter(s) Field (Continued)

Parameter / PID / Size Options Descriptions
Good Read DurationPID: 01h 04hSize: 00h 01h (1 Byte)- 00h- 01h- 02h- 03h- 04hShortMedium *LongExtremely longExtremely short
Good Read IndicatorPID: 01h 05hSize: 00h 01h (1 Byte)- 00h- 01hDisable(SE380-0,SE380-1,SE390-0,SE390-1,SE480-0, SE480-1*)Enable(SE380-9,SE390-9, SE480-9 *)
1D Barcode Inverse ReadingPID: 02h 00hSize: 00h 01h (1 Byte)- 00h- 01hDisable *Enable
Dollar Sign ControlPID: 02h 01hSize: 00h 01h (1 Byte)- 00h- 80h- A2h- A3h- A5hOutput as "$" *Output as "€"Output as "¢"Output as "£"Output as "¥"
RedundancyPID: 02h 02hSize: 00h 01h (1 Byte)- 00h- 01h- 02h- 03h- 04h- 05hNone1 time *2 times3 times4 times5 times
Data Transmission PacketPID: 02h 04hSize: 00h 01h (1 Byte)- 00h- 01hDisable *Enable
UPC/EAN Security LevelPID: 02h 06hSize: 00h 01h (1 Byte)- 00h- 01h- 02hLevel 0Level 1 *Level 2
Supplement Scan VotingPID: 02h 08hSize: 00h 01h (1 Byte)- 00h- 06h- 08h- 0Ah- 0Ch- 0Eh- 10h- 12h- 14h- 16h- 18h- 1Ah- 1Ch- 1EhNoneLevel 1Level 2Level 3 *Level 4Level 5Level 6Level 7Level 8Level 9Level 10Level 11Level 12Level 13
Operation Mode (Scan Engine)PID: 30h 00hSize: 00h 01h (1 Byte)- 00h- 01h- 02h- 04h- 06h- 09hTrigger mode (External triggering) *Force mode (Continued power on) (See Note)Presentation mode (Auto Detection)Level mode (Auto power off)Alternative mode (Periodic power off)Low Power mode (Low Power triggering)
I/O Active StatePID: 30h 01hSize: 00h 01h (1 Byte)- 00h- 01hHighLow *

. Note

Force mode is not available for SE390 and SE480 series.

Parameter(s)

< Table 6-2-1 > Set SE Operation Parameter(s) Field (Continued)

Parameter / PID / Size Options Descriptions
Laser Aiming Control
PID : 02h 09h- 00hDisable
Size : 00h 01h (1 Byte)- 01hEnable *
LED Illumination(See Note)
PID : 02h 0Bh- 00hAlways on
Size : 00h 01h (1 Byte)- 01hIntelligent Scanning *
Illumination Delay Duration(See Note)
PID : 02h 0Ch- 00h100ms
Size : 00h 01h (1 Byte)- 01h200ms
- 02h300ms
- 03h400ms
- 04h500ms

. Warning

  1. LED Illumination, Illumination Delay Duration are only available for SE390 and SE480 series.
  2. Laser Aiming Control is only available for SE398 and SE488

Get SE Operation (SE)

Descriptions

Request the desired one or more parameters of the Operation Settings for Scan Engine

Available for SE380, SE390 & SE480 series

Packet Format

PrefixOpcodeStatusLengthParameter(s)LRCSuffix
7EhC9h00h00hVariableSee BelowVariable7Eh
1 Byte3Bytes1 Byte2 BytesVariable1 Byte1 Byte
Parameter(s)
First Parameter......Last Parameter
PID Size ......PID Size
2 Bytes2 Bytes......2 Bytes2 Bytes
See Next Page

. Host Requirements

If the device successfully received the above command issued by the host, the device will pack all requested parameters into a "Reply SE Operation" message string then send to the host. Please refer to the "Reply SE Operation" command for details. Otherwise, a "Device NAK" will be sent to host to indicate issue a command error. However, if the host can receive any response from the device within the user preset time-out duration, please resend the above command.

. Parameter(s) Field

Get SE Operation can request multiple parameters at one time, so it takes compound parameters.

. Length

Total size (bytes) of the Parameter(s) field

.LRC

"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"

. Size

Total size (bytes) of the Options field

Parameter(s)

< Table 6-2-2 > Get SE Operation Parameter(s) Field

Parameter PID Size
Presentation Sensitivity 00h 03h00h 00h
Reread Delay 00h 04h00h 00h
Good Read Delay 00h 06h00h 00h
Scan Input Time-out 00h 07h00h 00h
Hands Free Time-out 00h 08h00h 00h
Time Delay To Low Power Mode 00h 09h00h 00h
Scan Rate Control 00h 0Bh00h 00h
Buzzer Tone Adjust 01h 00h00h 00h
Power on beep 01h 01h00h 00h
Good Read Duration 01h 04h00h 00h
Good Read Indicator 01h 05h00h 00h
1D Barcode Inverse Reading02h 00h00h 00h
Dollar Sign Control02h 01h00h 00h
Redundancy02h 02h00h 00h
Data Transmission Packet02h 04h00h 00h
UPC/EAN Security Level02h 06h00h 00h
Supplement Scan Voting02h 08h00h 00h
Operation Mode (Scan Engine)30h 00h00h 00h
I/O Active State30h 01h00h 00h
Laser Aiming Control02h 09h00h 00h
LED Illumination02h 0Bh00h 00h
Illumination Delay Duration02h 0Ch00h 00h

Reply SE Operation (SE)

Descriptions

Reply the desired one or more parameters of the Operation Settings for Scan Engine Reply SE Operation is sent by the device in response to the Get SE Operation command. It sends the values for all the desired parameters requested in the Get SE Operation command. Available for SE380, SE390 & SE480 series

Packet Format

PrefixOpcodeStatusLengthParameter(s)LRCSuffix
7Eh0Ah00h00hVariableSee BelowVariable7Eh
1 Byte3Bytes1 Byte2 BytesVariable1 Byte1 Byte
Parameter(s)
First Parameter......Last Parameter
PIDSizeOptions......PIDSizeOptions
2 Bytes2 BytesVariable......2 Bytes2 BytesVariable
See Next Page
Parameter(s)
First Parameter......Last Parameter
PIDSizeOptions......PIDSizeOptions
2 Bytes2 BytesVariable......2 Bytes2 BytesVariable
See Next Page

. Host Requirements

Since Reply SE Operation is a device-to-host message, there is no response for this message.

. Parameter(s) Field

Set SE Operation can change multiple parameters at one time, so it takes compound parameters.

. Length

Total size (bytes) of the Parameter(s) field

.LRC

"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"

. Size

Total size (bytes) of the Options field

Parameter(s)

< Table 6-2-3 > Reply SE Operation Parameter(s) Field (To be continued)

Parameter / PID / Size Options Descriptions
Presentation SensitivityPID : 00h 03hSize : 00h 01h (1 Byte)- 00h- 01h- 02h- 03h- 04h- 05h- 06hLevel 1Level 2Level 3Level 4Level 5 *Level 6Level 7
Reread DelayPID : 00h 04hSize : 00h 01h (1 Byte)- 00h- 01h- 02h- 03h- 04h- 05hDisableImmediate time-out duration *Short time-out durationMedium time-out durationLong time out-durationForce Verification
Good Read DelayPID : 00h 06hSize : 00h 01h (1 Byte)- 00h- 01h- 02h- 03h- 04h- 05h- 06hNone*200 ms500 ms1 s1.5 s2 s3 s
Scan Input Time-outPID : 00h 07hSize : 00h 01h (1 Byte)- 00h- 01h- 02h- 03h- 04h- 05h- 06h- 07h- 08h- XXh100ms200ms300ms400ms500ms600ms700ms800ms900ms *User-defined 1-99 s:XXh = desiredseconds(h) + 80h
Hands Free Time-outPID : 00h 08hSize : 00h 01h (1 Byte)- 00h- 06h- 0Ah- 0Eh- 12hDisableShort *MediumLongExtremely long
Time Delay To Low Power ModePID : 00h 09hSize : 00h 01h (1 Byte)- 00h- 01h- 02h- 03h- 04h- 05h1 s3 s5 s7 s9 s0 s (Immediately)*
Scan Rate ControlPID : 00h 0BhSize : 00h 01h (1 Byte)- 00h- 01hDynamic *Fixed
Buzzer Tone AdjustPID : 01h 00hSize : 00h 02h (2 Bytes) 1^st 2^nd Byte- 00h 00h- 01h 01h- 01h 02h- 01h 03h- 01h 04hMuteLowMedium *HighExtremely High

Parameter(s)

< Table 6-2-3 > Reply SE Operation Parameter(s) Field (Continued)

Parameter / PID / Size Options Descriptions
Power on beepPID : 01h 01hSize : 00h 01h (1 Byte)- 00h- 01hEnable (SE380/SE388-9 *)Disable (SE380/SE388-0, SE380/SE388-1 *)
Good Read DurationPID : 01h 04hSize : 00h 01h (1 Byte)- 00h- 01h- 02h- 03h- 04hShortMedium *LongExtremely longExtremely short
Good Read IndicatorPID : 01h 05hSize : 00h 01h (1 Byte)- 00h- 01hDisable(SE380-0,SE380-1,SE390-0,SE390-1,SE480-0, SE480-1*)Enable(SE380-9,SE390-9, SE480-9 *)
1D Barcode Inverse ReadingPID : 02h 00hSize : 00h 01h (1 Byte)- 00h- 01hDisable *Enable
Dollar Sign ControlPID : 02h 01hSize : 00h 01h (1 Byte)- 00h- 80h- A2h- A3h- A5hOutput as “$” *Output as “€”Output as “¢”Output as “£”Output as “¥”
RedundancyPID : 02h 02hSize : 00h 01h (1 Byte)- 00h- 01h- 02h- 03h- 04h- 05hNone1 time *2 times3 times4 times5 times
Data Transmission PacketPID : 02h 04hSize : 00h 01h (1 Byte)- 00h- 01hDisable *Enable
UPC/EAN Security LevelPID : 02h 06hSize : 00h 01h (1 Byte)- 00h- 01h- 02hLevel 0Level 1 *Level 2
Supplement Scan VotingPID : 02h 08hSize : 00h 01h (1 Byte)- 00h- 06h- 08h- 0Ah- 0Ch- 0Eh- 10h- 12h- 14h- 16h- 18h- 1Ah- 1Ch- 1EhNoneLevel 1Level 2Level 3 *Level 4Level 5Level 6Level 7Level 8Level 9Level 10Level 11Level 12Level 13
Operation Mode (Scan Engine)PID : 30h 00hSize : 00h 01h (1 Byte)- 00h- 01h- 02h- 04h- 06h- 09hTrigger mode (External triggering) *Force mode (Continued power on)Presentation mode (Auto Detection)Level mode (Auto power off)Alternative mode (Periodic power off)Low Power mode (Low Power triggering)
I/O Active StatePID : 30h 01hSize : 00h 01h (1 Byte)- 00h- 01hHighLow *

Parameter(s)

< Table 6-2-3 > Reply SE Operation Parameter(s) Field (Continued)

Parameter / PID / Size Options Descriptions
Laser Aiming Control
PID : 02h 09h- 00hDisable
Size : 00h 01h (1 Byte)- 01hEnable *
LED Illumination
PID : 02h 0Bh- 00hAlways on
Size : 00h 01h (1 Byte)- 01hIntelligent Scanning *
Illumination Delay Duration
PID : 02h 0Ch- 00h100ms
Size : 00h 01h (1 Byte)- 01h200ms
- 02h300ms
- 03h400ms
- 04h500ms

. Warning

  1. LED Illumination, Illumination Delay Duration are only available for SE390 and SE480 series.
  2. Laser Aiming Control is only available for SE398 and SE488

Set FS Operation (FS)

Descriptions

Change the desired one or more parameters of the Operation Settings for Fixed Mount and Scan Module

Available for FM480, FA470, SM380 & SM5700 series

Packet Format

PrefixOpcodeStatusLengthParameter(s)LRCSuffix
7Eh88h00h00hVariableSee BelowVariable7Eh
1 Byte3Bytes1 Byte2 BytesVariable1 Byte1 Byte
Parameter(s)
First Parameter......Last Parameter
PIDSizeOptions......PIDSizeOptions
2 Bytes2 BytesVariable......2 Bytes2 BytesVariable
See Next Page

. Host Requirements

If the device successfully received the above command issued by the host, a "Device ACK" will send to the host right after the device performed the action. Otherwise, a "Device NAK" will be sent to host to issue a command error. However, if the host can not receive any response from the device within the user preset time-out duration, please resend the above command.

. Parameter(s) Field

Set FS Operation can change multiple parameters at one time, so it takes compound parameters.

. Length

Total size (bytes) of the Parameter(s) field

.LRC

"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"

. Size

Total size (bytes) of the Options field

Parameter(s)

< Table 6-3-1 > Set FS Operation Parameter(s) Field (To be continued)

Parameter / PID / Size Options Descriptions
Presentation SensitivityPID : 00h 03hSize : 00h 01h (1 Byte)- 00h- 01h- 02h- 03h- 04h- 05h- 06hLevel 1Level 2Level 3Level 4Level 5 *Level 6Level 7
Reread DelayPID : 00h 04hSize : 00h 01h (1 Byte)- 00h- 01h- 02h- 03h- 04h- 05hDisableImmediate time-out duration *Short time-out durationMedium time-out durationLong time out-durationForce Verification
Good Read DelayPID : 00h 06hSize : 00h 01h (1 Byte)- 00h- 01h- 02h- 03h- 04h- 05h- 06hNone*200 ms500 ms1 s1.5 s2 s3 s
Hands Free Time-outPID : 00h 08hSize : 00h 01h (1 Byte)- 00h- 06h- 0Ah- 0Eh- 12hDisableShort *MediumLongExtremely long
Scan Rate ControlPID : 00h 0BhSize : 00h 01h (1 Byte)- 00h- 01h(See Notes)Dynamic *Fixed
Buzzer Tone AdjustPID : 01h 00hSize : 00h 02h (2 Bytes) 1^st 2^nd Byte- 00h 00h- 01h 01h- 01h 02h- 01h 03h- 01h 04hMuteLowMedium *HighExtremely High
Power on beepPID : 01h 01hSize : 00h 01h (1 Byte)- 00h- 01hEnable *Disable
Power on IndicationPID : 01h 02hSize : 00h 01h (1 Byte)- 00h- 01h- 02hLED OffLED On *LED Flash
Good Read DurationPID : 01h 04hSize : 00h 01h (1 Byte)- 00h- 01h- 02h- 03h- 04hShortMedium *LongExtremely longExtremely short

. Note

Scan Rate Control is available for FM480 & SM380 only.

Parameter(s)

< Table 6-3-1 > Set FS Operation Parameter(s) Field (Continued)

Parameter / PID / Size Options Descriptions
1D Barcode Inverse ReadingPID: 02h 00hSize: 00h 01h (1 Byte)- 00h- 01hDisable *Enable
Dollar Sign ControlPID: 02h 01hSize: 00h 01h (1 Byte)- 00h- 80h- A2h- A3h- A5hOutput as “” *Output as “€”Output as “¢”Output as “£”Output as “¥”
RedundancyPID: 02h 02hSize: 00h 01h (1 Byte)- 00h- 01h- 02h- 03h- 04h- 05hNone1 time *2 times3 times4 times5 times
Data Transmission PacketPID: 02h 04hSize: 00h 01h (1 Byte)- 00h- 01hDisable *Enable
UPC/EAN Security LevelPID: 02h 06hSize: 00h 01h (1 Byte)- 00h- 01h- 02hLevel 0Level 1 *Level 2
Supplement Scan VotingPID: 02h 08hSize: 00h 01h (1 Byte)- 00h- 06h- 08h- 0Ah- 0Ch- 0Eh- 10h- 12h- 14h- 16h- 18h- 1Ah- 1Ch- 1EhNoneLevel 1Level 2Level 3 *Level 4Level 5Level 6Level 7Level 8Level 9Level 10Level 11Level 12Level 13
Operation Mode(FM480 & SM380 series)PID: 20h 00hSize: 00h 01h (1 Byte)- 00h- 01h- 02h- 04h- 06hTrigger mode (External triggering) *Force mode (Continued power on)Presentation mode (Auto Detection)Level mode (Auto power off)Alternative mode (Periodic power off)
NG Message OutputPID: 20h 04hSize: 00h 10h (16 Bytes)1^{st} \sim 16^{th}$ Byte- 00h 00h...00h- 02h 4Eh 47h00h...00h- XXh XXh...XXhDisable * (Totally sixteen “00h”s)Output “NG” (Totally thirteen “00h”s)(See Note under the table)Output User-defined message

. Note

NG Message Output carries 16 bytes in the Options Field. The 1st byte which indicates the length of the message is followed by the message characters. If the desired ASCII characters for setting the message are shorter than 15 bytes, the rest bytes should be set to 00h. For example, to output "BAD", the 1st byte is 03h (length of "BAD"), the 2^nd to 4^th byte is 42h 41h 44h (ASCII value of "BAD"), and from the 5^th byte to the 16^th byte are all 00h.

Parameter(s)

< Table 5-3 > Set FS Operation Parameter(s) Field (Continued)

Parameter / PID / Size Options Descriptions
OK/NG Active Signal ControlPID : 20h 01hSize : 00h 03h (3 Bytes) 1^st Byte- 00h- 01h- 02h- 03h 2^nd Byte- 00h- 01h- 02h- 03h 3^rd Byte- 01h- 02h- 03h- 04h- 05h- 06h- 07h- 08h- 09h- 0Ah- XXhOK/NG Active Signal OutputDisableEnable NG onlyEnable OK onlyEnable*OK/NG Active Signal StateOK Low/ NG Low*OK Low/ NG HighOK High/ NG LowOK High/ NG HighOK/NG Active Duration10ms20ms30ms40ms50ms60ms70ms80ms90ms100ms *User-defined (See Note under the table)
OK/NG Beep ControlPID : 20h 02hSize : 00h 02h (2 Bytes) 1^st 2^nd Byte- 00h 00h- 01h 01h- 00h 01h- 01h 00hDisableEnable *Enable OK onlyEnable NG only
Scan Input Time-outPID : 20h 03hSize : 00h 01h (1 Byte)- 00h- 01h- 02h- 03h- 04h- 05h- 06h- 07h- 08h- XXh100ms200ms300ms400ms500ms600ms700ms800ms900ms*User-defined (See Note under the table)

. Notes

  1. OK/ NG Active Duration can be set to User-defined 1\~99(×5) milliseconds. XXh = desired milliseconds (h) + 80h. For example, if you want to set it to 99 (×5) ms (the actual value is 495 ms), you need to convert 99 from Dec to Hex, that is, 63h. Then, XXh = 63h + 80h = E3h.
  2. Scan Input Time-out can be set to User-defined 1\~99 seconds. XXh = desired seconds (h) + 80h. For example, if you want to set this parameter to 99 seconds, you need to convert 99 from Dec to Hex, that is, 63h. Then, XXh = 63h + 80h = E3h.

Parameter(s)

< Table 5-3 > Set FS Operation Parameter(s) Field (Continued)

Parameter / PID / Size Options Descriptions
Operation Mode(FA470 & SM5700 series)PID : 70h 00hSize : 00h 03h (3 Bytes)- 00h 01h 01h- 01h 01h 01h- 02h 01h 01h- 04h 01h 00h- 06h 01h 00h(See Notes)Trigger mode *Force modePresentation modeLevel modeAlternative mode
Hand-Held Mode Illumination& Aiming ControlPID : 70h 01hSize : 00h 01h (1 Byte)Bit 0- 0- 1Bit 1- 0- 1Hand-Held Decode Aiming ControlDisableEnable *Hand-Held Illumination ControlDisableEnable *
Hand-Free Mode DecodeAiming ControlPID : 70h 02hSize : 00h 01h (1 Byte)- 02h- 03h(See Notes)DisableEnable *
Aiming ControlPID : 70h 03hSize : 00h 02h (2 Bytes)- 00h 00h- 01h 00h- 00h 03h(See Notes)Regular AimingIntelligent Aiming *Delay Aiming Control
Delay Aiming TimeoutControlPID : 70h 04hSize : 00h 01h (1 Byte)- 02h- 04h- 08h- 0Ah- 0Fh- 14h- 1Eh- 28h(See Notes)200ms400ms *800ms1000ms1500ms2000ms3000ms4000ms
Presentation BackgroundLightingPID : 70h 05hSize : 00h 02h (2 Bytes)- 00h 00h- 00h FFh(See Notes)LEDs OffLEDs On *
Center AlignmentPID : 70h 06hSize : 00h 02h (2 Bytes)1st Byte- 00h- 01h2nd Byte- 00h- 01h(See Notes)Hand-Held ModeDisable *EnableHand-Free ModeDisable *Enable
Mobile Phone CapturePID : 70h 07hSize : 00h 01h (1 Byte)- 00h- 01h(See Notes)Disable *Enable

. Note

Hand-Held Mode Illumination & Aiming Control, Hand-Free Mode Decode Aiming Control, Aiming Control, Delay Aiming Timeout, Presentation Background Lighting, Center Alignment and Mobile Phone Capture are available for FA470 & SM5700 only.

Get FS Operation (FS)

Descriptions

Request the desired one or more parameters of the Operation Settings for Fixed Mount and Scan Module

Available for FM480, FA470, SM380 & SM5700 series

Packet Format

PrefixOpcodeStatusLengthParameter(s)LRCSuffix
7EhC9h 00h 00h00hVariableSee Below Variable7Eh
1 Byte3Bytes1 Byte2 BytesVariable1 Byte1 Byte
Parameter(s)
First Parameter......Last Parameter
PID Size......PID Size
2 Bytes2 Bytes......2 Bytes2 Bytes
See Next Page

. Host Requirements

If the device successfully received the above command issued by the host, the device will pack all requested parameters into a "Reply FS Operation" message string then send to the host. Please refer to the "Reply FS Operation" command for details. Otherwise, a "Device NAK" will be sent to host to indicate issue a command error. However, if the host can receive any response from the device within the user preset time-out duration, please resend the above command.

. Parameter(s) Field

Get FS Operation can request multiple parameters at one time, so it takes compound parameters.

.Length

Total size (bytes) of the Parameter(s) field

.LRC

"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"

. Size

Total size (bytes) of the Options field

Parameter(s)

< Table 6-3-2 > Get FS Operation Parameter(s) Field

Parameter PID Size
Presentation Sensitivity 00h 03h00h 00h
Reread Delay 00h 04h00h 00h
Good Read Delay 00h 06h00h 00h
Hands Free Time-out 00h 08h00h 00h
Scan Rate Control 00h 0Bh00h 00h
Buzzer Tone Adjust 01h 00h00h 00h
Power on beep 01h 01h00h 00h
Power on Indication 01h 02h00h 00h
Good Read Duration 01h 04h00h 00h
1D Barcode Inverse Reading 02h 00h00h 00h
Dollar Sign Control02h 01h00h 00h
Redundancy02h 02h00h 00h
Data Transmission Packet02h 04h00h 00h
UPC/EAN Security Level02h 06h00h 00h
Supplement Scan Voting02h 08h00h 00h
Operation Mode(FM480 & SM380 series)20h 00h00h 00h
NG Message Output20h 04h00h 00h
OK/NG Active Signal Control20h 01h00h 00h
OK/NG Beep Control20h 02h00h 00h
Scan Input Time-out20h 03h00h 00h
Operation Mode (FA470 & SM5700 series) 70h 00h00h 00h
Hand-Held Mode Illumination & Aiming Control70h 01h00h 00h
Hand-Free Mode Decode Aiming Control70h 02h00h 00h
Aiming Control70h 03h00h 00h
Delay Aiming Timeout70h 04h00h 00h
Presentation Background Lighting70h 05h00h 00h
Center Alignment 70h 06h00h 00h
Mobile Phone Capture70h 07h00h 00h

Reply FS Operation (FS)

Descriptions

Reply the desired one or more parameters of the Operation Settings for Fixed Mount and Scan Module

Reply FS Operation is sent by the device in response to the Get FS Operation command. It sends the values for all the desired parameters requested in the Get FS Operation command.

Available for FM480, FA470, SM380 & SM5700 series

Packet Format

PrefixOpcodeStatusLengthParameter(s)LRCSuffix
7Eh0Ah00h00hVariableSee BelowVariable7Eh
1 Byte3Bytes1 Byte2 BytesVariable1 Byte1 Byte
Parameter(s)
First Parameter......Last Parameter
PIDSizeOptions......PIDSizeOptions
2 Bytes2 BytesVariable......2 Bytes2 BytesVariable
See Next Page

. Host Requirements

Since Reply FS Operation is a device-to-host message, there is no response for this message.

. Parameter(s) Field

Set FS Operation can change multiple parameters at one time, so it takes compound parameters.

. Length

Total size (bytes) of the Parameter(s) field

.LRC

"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"

. Size

Total size (bytes) of the Options field

Parameter(s)

< Table 6-3-3 > Reply FS Operation Parameter(s) Field (To be continued)

Parameter / PID / Size Options Descriptions
Presentation SensitivityPID : 00h 03hSize : 00h 01h (1 Byte)- 00h- 01h- 02h- 03h- 04h- 05h- 06hLevel 1Level 2Level 3Level 4Level 5 *Level 6Level 7
Reread DelayPID : 00h 04hSize : 00h 01h (1 Byte)- 00h- 01h- 02h- 03h- 04h- 05hDisableImmediate time-out duration *Short time-out durationMedium time-out durationLong time out-durationForce Verification
Good Read DelayPID : 00h 06hSize : 00h 01h (1 Byte)- 00h- 01h- 02h- 03h- 04h- 05h- 06hNone*200 ms500 ms1 s1.5 s2 s3 s
Hands Free Time-outPID : 00h 08hSize : 00h 01h (1 Byte)- 00h- 06h- 0Ah- 0Eh- 12hDisableShort *MediumLongExtremely long
Scan Rate ControlPID : 00h 0BhSize : 00h 01h (1 Byte)- 00h- 01h(See Notes)Dynamic *Fixed
Buzzer Tone AdjustPID : 01h 00hSize : 00h 02h (2 Bytes) 1^st 2^nd Byte- 00h 00h- 01h 01h- 01h 02h- 01h 03h- 01h 04hMuteLowMedium *HighExtremely High
Power on beepPID : 01h 01hSize : 00h 01h (1 Byte)- 00h- 01hEnable *Disable
Power on IndicationPID : 01h 02hSize : 00h 01h (1 Byte)- 00h- 01h- 02hLED OffLED On *LED Flash
Good Read DurationPID : 01h 04hSize : 00h 01h (1 Byte)- 00h- 01h- 02h- 03h- 04hShortMedium *LongExtremely longExtremely short

. Note

Scan Rate Control is available for FM480 & SM380 only.

Parameter(s)

< Table 6-3-3 > Reply FS Operation Parameter(s) Field (Continued)

Parameter / PID / Size Options Descriptions
1D Barcode Inverse ReadingPID: 02h 00hSize: 00h 01h (1 Byte)- 00h- 01hDisable *Enable
Dollar Sign ControlPID: 02h 01hSize: 00h 01h (1 Byte)- 00h- 80h- A2h- A3h- A5hOutput as “” *Output as “€”Output as “¢”Output as “£”Output as “¥”
RedundancyPID: 02h 02hSize: 00h 01h (1 Byte)- 00h- 01h- 02h- 03h- 04h- 05hNone1 time *2 times3 times4 times5 times
Data Transmission PacketPID: 02h 04hSize: 00h 01h (1 Byte)- 00h- 01hDisable *Enable
UPC/EAN Security LevelPID: 02h 06hSize: 00h 01h (1 Byte)- 00h- 01h- 02hLevel 0Level 1 *Level 2
Supplement Scan VotingPID: 02h 08hSize: 00h 01h (1 Byte)- 00h- 06h- 08h- 0Ah- 0Ch- 0Eh- 10h- 12h- 14h- 16h- 18h- 1Ah- 1Ch- 1EhNoneLevel 1Level 2Level 3 *Level 4Level 5Level 6Level 7Level 8Level 9Level 10Level 11Level 12Level 13
Operation Mode(FM480 & SM380 series)PID: 20h 00hSize: 00h 01h (1 Byte)- 00h- 01h- 02h- 04h- 06hTrigger mode (External triggering) *Force mode (Continued power on)Presentation mode (Auto Detection)Level mode (Auto power off)Alternative mode (Periodic power off)
NG Message OutputPID: 20h 04hSize: 00h 10h (16 Bytes)1^{st} \sim 16^{th}$ Byte- 00h 00h...00h- 02h 4Eh 47h00h...00h- XXh XXh...XXhDisable * (Totally sixteen “00h”s)Output “NG” (Totally thirteen “00h”s)(See Note under the table)Output User-defined message

. Note

NG Message Output carries 16 bytes in the Options Field. The 1st byte which indicates the length of the message is followed by the message characters. If the desired ASCII characters for setting the message are shorter than 15 bytes, the rest bytes should be set to 00h. For example, to output "BAD", the 1st byte is 03h (length of "BAD"), the 2^nd to 4^th byte is 42h 41h 44h (ASCII value of "BAD"), and from the 5^th byte to the 16^th byte are all 00h.

Parameter(s)

< Table 6-3-3 > Reply FS Operation Parameter(s) Field (Continued)

Parameter / PID / Size Options Descriptions
OK/NG Active Signal ControlPID : 20h 01hSize : 00h 03h (3 Bytes) 1^st Byte- 00h- 01h- 02h- 03h 2^nd Byte- 00h- 01h- 02h- 03h 3^rd Byte- 01h- 02h- 03h- 04h- 05h- 06h- 07h- 08h- 09h- 0Ah- XXhOK/NG Active Signal OutputDisableEnable NG onlyEnable OK onlyEnable*OK/NG Active Signal StateOK Low/ NG Low*OK Low/ NG HighOK High/ NG LowOK High/ NG HighOK/NG Active Duration10ms20ms30ms40ms50ms60ms70ms80ms90ms100ms *User-defined (See Note under the table)
OK/NG Beep ControlPID : 20h 02hSize : 00h 02h (2 Bytes) 1^st 2^nd Byte- 00h 00h- 01h 01h- 00h 01h- 01h 00hDisableEnable *Enable OK onlyEnable NG only
Scan Input Time-outPID : 20h 03hSize : 00h 01h (1 Byte)- 00h- 01h- 02h- 03h- 04h- 05h- 06h- 07h- 08h- XXh100ms200ms300ms400ms500ms600ms700ms800ms900ms*User-defined (See Note under the table)

.Notes

  1. OK/ NG Active Duration can be set to User-defined 1\~99(×5) milliseconds. XXh = desired milliseconds (h) + 80h. For example, if you want to set it to 99 (×5) ms (the actual value is 495 ms), you need to convert 99 from Dec to Hex, that is, 63h. Then, XXh = 63h + 80h = E3h.
  2. Scan Input Time-out can be set to User-defined 1\~99 seconds. XXh = desired seconds (h) + 80h. For example, if you want to set this parameter to 99 seconds, you need to convert 99 from Dec to Hex, that is, 63h. Then, XXh = 63h + 80h = E3h.

Parameter(s)

< Table 6-3-3 > Reply FS Operation Parameter(s) Field (Continued)

Parameter / PID / Size Options Descriptions
Operation Mode(FA470 & SM5700 series)PID : 70h 00hSize : 00h 03h (3 Bytes)- 00h 01h 01h- 01h 01h 01h- 02h 01h 01h- 04h 01h 00h- 06h 01h 00h(See Notes)Trigger mode *Force modePresentation modeLevel modeAlternative mode
Hand-Held Mode Illumination& Aiming ControlPID : 70h 01hSize : 00h 01h (1 Byte)Bit 0- 0- 1Bit 1- 0- 1Hand-Held Decode Aiming ControlDisableEnable *Hand-Held Illumination ControlDisableEnable *
Hand-Free Mode DecodeAiming ControlPID : 70h 02hSize : 00h 01h (1 Byte)- 02h- 03h(See Notes)DisableEnable *
Aiming ControlPID : 70h 03hSize : 00h 02h (2 Bytes)- 00h 00h- 01h 00h- 00h 03h(See Notes)Regular AimingIntelligent Aiming *Delay Aiming Control
Delay Aiming TimeoutControlPID : 70h 04hSize : 00h 01h (1 Byte)- 02h- 04h- 08h- 0Ah- 0Fh- 14h- 1Eh- 28h(See Notes)200ms400ms *800ms1000ms1500ms2000ms3000ms4000ms
Presentation BackgroundLightingPID : 70h 05hSize : 00h 02h (2 Bytes)- 00h 00h- 00h FFh(See Notes)LEDs OffLEDs On *
Center AlignmentPID : 70h 06hSize : 00h 02h (2 Bytes)1st Byte- 00h- 01h2nd Byte- 00h- 01h(See Notes)Hand-Held ModeDisable *EnableHand-Free ModeDisable *Enable
Mobile Phone CapturePID : 70h 07hSize : 00h 01h (1 Byte)- 00h- 01h(See Notes)Disable *Enable

. Note

Hand-Held Mode Illumination & Aiming Control, Hand-Free Mode Decode Aiming Control, Aiming Control, Delay Aiming Timeout, Presentation Background Lighting, Center Alignment and Mobile Phone Capture are available for FA470 & SM5700 only.

Set BT Operation (BT)

Descriptions

Change the desired one or more parameters of the Operation Settings for Bluetooth Scanner Available for F, L & A series

Packet Format

PrefixOpcodeStatusLengthParameter(s)LRCSuffix
7Eh88h00h00hVariableSee Below Variable7Eh
1 Byte3Bytes1 Byte2 Bytes/Variable1 Byte 1 Byte
Parameter(s)
First Parameter ......Last Parameter
PIDSizeOptions......PIDSizeOptions
2 Bytes2 BytesVariable......2 Bytes2 BytesVariable
See Next Page

. Host Requirements

If the device successfully received the above command issued by the host, a "Device ACK" will send to the host right after the device performed the action. Otherwise, a "Device NAK" will be sent to host to issue a command error. However, if the host can not receive any response from the device within the user preset time-out duration, please resend the above command.

. Parameter(s) Field

Set BT Operation can change multiple parameters at one time, so it takes compound parameters.

. Length

Total size (bytes) of the Parameter(s) field

.LRC

"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"

. Size

Total size (bytes) of the Options field

Parameter(s)

< Table 6-4-1 > Set BT Operation Parameter(s) Field (To be continued)

Parameter / PID / Size Options Descriptions
Presentation Auto-sensePID : 00h 02hSize : 00h 01h (1 Byte)- 00h- 01hDisable *Enable
Presentation SensitivityPID : 00h 03hSize : 00h 01h (1 Byte)- 00h- 01h- 02h- 03h- 04h- 05h- 06hLevel 1Level 2Level 3Level 4Level 5 *Level 6Level 7
Reread DelayPID : 00h 04hSize : 00h 01h (1 Byte)- 00h- 01h- 02h- 03h- 04h- 05hDisableImmediate time-out duration *Short time-out durationMedium time-out durationLong time out-durationForce Verification
Good Read DelayPID : 00h 06hSize : 00h 01h (1 Byte)- 00h- 01h- 02h- 03h- 04h- 05h- 06hNone*200 ms500 ms1 s1.5 s2 s3 s
Light Source On TimePID : 00h 07hSize : 00h 01h (1 Byte)- 00h- 01h- 02h- 03hShort (about 2 s) (L & F Series *)Medium (about 3~4 s)Long (about 5~6 s) (A Series *)Extremely Long (about 7~8 s)
Hands Free Time-outPID : 00h 08hSize : 00h 01h (1 Byte)- 00h- 06h- 0Ah- 0Eh- 12hDisableShort *MediumLongExtremely long
Time Delay To Low Power ModePID : 00h 09hSize : 00h 01h (1 Byte)- 00h- 01h- 02h- 03h- 04h- 05h1 s3 s5 s7 s9 s0 s (Immediately)*
Scan Rate ControlPID : 00h 0BhSize : 00h 01h (1 Byte)- 00h- 01hDynamic *Fixed
Buzzer Tone AdjustPID : 01h 00hSize : 00h 02h (2 Bytes) 1^st 2^nd Byte- 00h 00h- 01h 01h- 01h 02h- 01h 03h- 01h 04hMuteLowMedium *HighExtremely High
Power on beepPID : 01h 01hSize : 00h 01h (1 Byte)- 00h- 01hEnable *Disable

Parameter(s)

< Table 6-4-1 > Set BT Operation Parameter(s) Field (Continued)

Parameter / PID / Size Options Descriptions
Power on IndicationPID: 01h 02hSize: 00h 01h (1 Byte)- 00h- 01h- 02hLED OffLED On *LED Flash
VibratorPID: 01h 03hSize: 00h 01h (1 Byte)- 00h- 01hDisableEnable *
Good Read DurationPID: 01h 04hSize: 00h 01h (1 Byte)- 00h- 01h- 02h- 03h- 04hShortMedium *LongExtremely longExtremely short
Good Read IndicatorPID: 01h 05hSize: 00h 01h (1 Byte)- 00h- 01hDisableEnable *
Beeping ControlPID: 01h 06hSize: 00h 01h (1 Byte)Bit 0- 0- 1Bit 1- 0- 1Radio Connection BeepEnable *DisableBattery Power Low BeepEnable *Disable
1D Barcode Inverse ReadingPID: 02h 00hSize: 00h 01h (1 Byte)- 00h- 01hDisable *Enable
Dollar Sign ControlPID: 02h 01hSize: 00h 01h (1 Byte)- 00h- 80h- A2h- A3h- A5hOutput as “$” *Output as “€”Output as “¢”Output as “£”Output as “¥”
RedundancyPID: 02h 02hSize: 00h 01h (1 Byte)- 00h- 01h- 02h- 03h- 04h- 05hNone1 time *2 times3 times4 times5 times
Data Transmission Packet (PAIR / PICO Mode)PID: 52h 00hSize: 00h 01h (1 Byte)- 00h- 01h- 02h- 03h- 04h- 05h- 06h- 07hDisable packet *With MACWith IDWith MAC and IDEnable packetMAC packetID packetMAC and ID packet
Data Transmission Packet (HID/ SPP Mode)PID: 52h 00hSize: 00h 01h (1 Byte)- 00h- 01hDisable packet *Enable packet

. Warning

If you are using the SmartCradle to communicate with the Scanner, "BT Synchronization" command should be sent to the scanner after the setting of the "Dollar Sign Control" and "Data Transmission Packet" to sync the Scanner with the SmartCradle, so that the settings will take effect immediately.

Parameter(s)

< Table 6-4-1 > Set BT Operation Parameter(s) Field (Continued)

Parameter / PID / Size Options Descriptions
UPC/EAN Security LevelPID: 02h 06hSize: 00h 01h (1 Byte)- 00h- 01h- 02hLevel 0Level 1 *Level 2
Supplement Scan VotingPID: 02h 08hSize: 00h 01h (1 Byte)- 00h- 06h- 08h- 0Ah- 0Ch- 0Eh- 10h- 12h- 14h- 16h- 18h- 1Ah- 1Ch- 1EhNoneLevel 1Level 2Level 3 *Level 4Level 5Level 6Level 7Level 8Level 9Level 10Level 11Level 12Level 13
Operation Mode(Bluetooth F & L Series)PID: 50h 00hSize: 00h 01h (1 Byte)- 00h- 02hTrigger mode (External triggering) *Presentation mode (Auto Detection)
Batch Scanning Link ControlPID: 51h 00hSize: 00h 01h (1 Byte)- 00h- 01hRadio DisableRadio Enable *
Stored Data TransmissionPID: 51h 01hSize: 00h 01h (1 Byte)- 00h- 01h- 02hAll *On-cradleScan Barcode
Delete Stored Data AfterTransmissionPID: 51h 02hSize: 00h 01h (1 Byte)- 00h- 01hDisable *Enable
Field DelimiterPID: 51h 03hSize: 00h 01h (1 Byte)- 00h- 2Ch- 20h- 2Dh- 2Eh- XXhNone<,> *User-defined 00~7Fh<-><.->
Batch Data Quantity OutputFormatPID: 51h 04hSize: 00h 01h (1 Byte)- 00h- 01h- 02hAs many times as the quantity indicates *

. Warning

If you are using the SmartCradle to communicate with the Scanner, "BT Synchronization" command should be sent to the scanner after the setting of the "Field Delimiter" to sync the Scanner with the SmartCradle, so that the settings will take effect immediately.

Parameter(s)

< Table 6-4-1 > Set BT Operation Parameter(s) Field (Continued)

Parameter / PID / Size Options Descriptions
Laser Aiming ControlPID : 02h 09hSize : 00h 01h (1 Byte)- 00h- 01hDisableEnable *
LED IlluminationPID : 02h 0BhSize : 00h 01h (1 Byte)- 00h- 01hAlways onIntelligent Scanning *
Illumination Delay DurationPID : 02h 0ChSize : 00h 01h (1 Byte)- 00h- 01h- 02h- 03h- 04h100ms200ms300ms400ms500ms
Operation Mode(Bluetooth A Series)PID : 70h 00hSize : 00h 03h (3 Bytes)- 00h 01h 01h- 02h 01h 01hTrigger mode *Presentation mode
Hand-Held Mode Illumination& Aiming ControlPID : 70h 01hSize : 00h 01h (1 Byte)Bit 0- 0- 1Bit 1- 0- 1Hand-Held Decode Aiming ControlDisableEnable *Hand-Held Illumination ControlDisableEnable *
Hand-Free Mode DecodeAiming ControlPID : 70h 02hSize : 00h 01h (1 Byte)- 02h- 03hDisableEnable *
Aiming ControlPID : 70h 03hSize : 00h 02h (2 Bytes)- 00h 00h- 01h 00h- 00h 03hRegular Aiming *Intelligent AimingDelay Aiming Control

.Notes

  1. LED Illumination, Illumination Delay Duration are only available for L680BT, L688BT, L780BT, L788BT.
  2. Laser Aiming Control is only available for L688BT, L788BT
  3. Hand-Held Mode Illumination & Aiming Control, Hand-Free Mode Decode Aiming Control and Aiming Control are available for A Series only.

Parameter(s)

< Table 6-1-1 > Set BT Operation Parameter(s) Field (Continued)

Parameter / PID / Size Options Descriptions
Delay Aiming TimeoutControlPID : 70h 04hSize : 00h 01h (1 Byte)- 02h- 04h- 08h- 0Ah- 0Fh- 14h- 1Eh- 28h200ms400ms *800ms1000ms1500ms2000ms3000ms4000ms
Presentation BackgroundLightingPID : 70h 05hSize : 00h 02h (2 Bytes)- 00h 00h- 00h FFhLEDs OffLEDs On *
Center AlignmentPID : 70h 06hSize : 00h 02h (2 Bytes)1st Byte- 00h- 01h2nd Byte- 00h- 01hHand-Held ModeDisable *EnableHand-Free ModeDisable *Enable
Mobile Phone CapturePID : 70h 07hSize : 00h 01h (1 Byte)- 00h- 01hDisable *Enable

Notes

Delay Aiming Timeout, Presentation Background Lighting, Center Alignment and Mobile Phone Capture are available for A Series only.

Get BT Operation (BT)

Descriptions

Request the desired one or more parameters of the Operation Settings for Bluetooth Scanner Available for F, L & A series

Packet Format

Prefix Opcode Status Length

7Eh

C9h 00h 00h

00h Variable

If the device successfully received the above command issued by the host, the device will pack all requested parameters into a “Reply BT Operation” message string then send to the host. Please refer to the “Reply BT Operation” command for details. Otherwise, a “Device NAK” will be sent to host to indicate issue a command error. However, if the host can receive any response from the device within the user preset time-out duration, please resend the above command.

. Parameter(s) Field

Get BT Operation can request multiple parameters at one time, so it takes compound parameters.

. Length

Total size (bytes) of the Parameter(s) field

.LRC

"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"

. Size

Total size (bytes) of the Options field

Parameter(s)

< Table 6-4-2 > Get BT Operation Parameter(s) Field

Parameter PID Size
Presentation Auto-sense 00h 02h00h 00h
Presentation Sensitivity 00h 03h00h 00h
Reread Delay 00h 04h00h 00h
Good Read Delay 00h 06h00h 00h
Light Source On Time 00h 07h00h 00h
Hands Free Time-out 00h 08h00h 00h
Time Delay To Low Power Mode 00h 09h00h 00h
Scan Rate Control 00h 0Bh00h 00h
Buzzer Tone Adjust 01h 00h00h 00h
Power on beep01h 01h00h 00h
Power on Indication01h 02h00h 00h
Vibrator01h 03h00h 00h
Good Read Duration01h 04h00h 00h
Good Read Indicator01h 05h00h 00h
Beeping Control01h 06h00h 00h
1D Barcode Inverse Reading02h 00h00h 00h
Dollar Sign Control02h 01h00h 00h
Redundancy02h 02h00h 00h
Data Transmission Packet52h 00h00h 00h
UPC/EAN Security Level02h 06h00h 00h
Supplement Scan Voting 02h 08h00h 00h
Operation Mode (Bluetooth F & L Series)50h 00h00h 00h
Batch Scanning Link Control51h 00h00h 00h
Stored Data Transmission51h 01h00h 00h
Delete Stored Data After Transmission51h 02h00h 00h
Field Delimiter51h 03h00h 00h
Batch Data Quantity Output Format51h 04h00h 00h
Laser Aiming Control02h 09h00h 00h
LED Illumination02h 0Bh00h 00h
Illumination Delay Duration02h 0Ch00h 00h
Operation Mode (Bluetooth A Series)70h 00h00h 00h
Hand-Held Mode Illumination & Aiming Control70h 01h00h 00h
Hand-Free Mode Decode Aiming Control70h 02h00h 00h
Aiming Control70h 03h00h 00h
Delay Aiming Timeout70h 04h00h 00h
Presentation Background Lighting70h 05h00h 00h
Center Alignment 70h 06h00h 00h
Mobile Phone Capture70h 07h00h 00h

Reply BT Operation (BT)

Descriptions

Reply the desired one or more parameters of the Operation Settings for Bluetooth Scanner Reply BT Operation is sent by the device in response to the Get BT Operation command. It sends the values for all the desired parameters requested in the Get BT Operation command. Available for F, L & A series

Packet Format

PrefixOpcodeStatusLengthParameter(s)LRCSuffix
7Eh0Ah00h 00h00hVariableSee Below Variable7Eh
1 Byte3Bytes1 Byte2 BytesVariable1 Byte1 Byte
Parameter(s)
First Parameter......Last Parameter
PIDSizeOptions......PIDSizeOptions
2 Bytes2 BytesVariable......2 Bytes2 BytesVariable
See Next Page

. Host Requirements

Since Reply BT Operation is a device-to-host message, there is no response for this message.

. Parameter(s) Field

Reply BT Operation can change multiple parameters at one time, so it takes compound parameters.

. Length

Total size (bytes) of the Parameter(s) field

.LRC

"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"

. Size

Total size (bytes) of the Options field

Parameter(s)

< Table 6-4-3 > Reply BT Operation Parameter(s) Field (To be continued)

Parameter / PID / Size Options Descriptions
Presentation Auto-sensePID : 00h 02hSize : 00h 01h (1 Byte)- 00h- 01hDisable *Enable
Presentation SensitivityPID : 00h 03hSize : 00h 01h (1 Byte)- 00h- 01h- 02h- 03h- 04h- 05h- 06hLevel 1Level 2Level 3Level 4Level 5 *Level 6Level 7
Reread DelayPID : 00h 04hSize : 00h 01h (1 Byte)- 00h- 01h- 02h- 03h- 04h- 05hDisableImmediate time-out duration *Short time-out durationMedium time-out durationLong time out-durationForce Verification
Good Read DelayPID : 00h 06hSize : 00h 01h (1 Byte)- 00h- 01h- 02h- 03h- 04h- 05h- 06hNone*200 ms500 ms1 s1.5 s2 s3 s
Light Source On TimePID : 00h 07hSize : 00h 01h (1 Byte)- 00h- 01h- 02h- 03hShort (about 2 s) (L & F Series *)Medium (about 3~4 s)Long (about 5~6 s) (A Series *)Extremely Long (about 7~8 s)
Hands Free Time-outPID : 00h 08hSize : 00h 01h (1 Byte)- 00h- 06h- 0Ah- 0Eh- 12hDisableShort *MediumLongExtremely long
Time Delay To Low Power ModePID : 00h 09hSize : 00h 01h (1 Byte)- 00h- 01h- 02h- 03h- 04h- 05h1 s3 s5 s7 s9 s0 s (Immediately)*
Scan Rate ControlPID : 00h 0BhSize : 00h 01h (1 Byte)- 00h- 01hDynamic *Fixed
Buzzer Tone AdjustPID : 01h 00hSize : 00h 02h (2 Bytes) 1^st 2^nd Byte- 00h 00h- 01h 01h- 01h 02h- 01h 03h- 01h 04hMuteLowMedium *HighExtremely High
Power on beepPID : 01h 01hSize : 00h 01h (1 Byte)- 00h- 01hEnable *Disable

Parameter(s)

< Table 6-4-3 > Reply BT Operation Parameter(s) Field (Continued)

Parameter / PID / Size Options Descriptions
Power on IndicationPID: 01h 02hSize: 00h 01h (1 Byte)- 00h- 01h- 02hLED OffLED On *LED Flash
VibratorPID: 01h 03hSize: 00h 01h (1 Byte)- 00h- 01hDisableEnable *
Good Read DurationPID: 01h 04hSize: 00h 01h (1 Byte)- 00h- 01h- 02h- 03h- 04hShortMedium *LongExtremely longExtremely short
Good Read IndicatorPID: 01h 05hSize: 00h 01h (1 Byte)- 00h- 01hDisableEnable *
Beeping ControlPID: 01h 06hSize: 00h 01h (1 Byte)Bit 0- 0- 1Bit 1- 0- 1Radio Connection BeepEnable *DisableBattery Power Low BeepEnable *Disable
1D Barcode Inverse ReadingPID: 02h 00hSize: 00h 01h (1 Byte)- 00h- 01hDisable *Enable
Dollar Sign ControlPID: 02h 01hSize: 00h 01h (1 Byte)- 00h- 80h- A2h- A3h- A5hOutput as “$” *Output as “€”Output as “¢”Output as “£”Output as “¥”
RedundancyPID: 02h 02hSize: 00h 01h (1 Byte)- 00h- 01h- 02h- 03h- 04h- 05hNone1 time *2 times3 times4 times5 times
Data Transmission Packet (PAIR / PICO Mode)PID: 52h 00hSize: 00h 01h (1 Byte)- 00h- 01h- 02h- 03h- 04h- 05h- 06h- 07hDisable packet *With MACWith IDWith MAC and IDEnable packetMAC packetID packetMAC and ID packet
Data Transmission Packet (HID/ SPP Mode)PID: 52h 00hSize: 00h 01h (1 Byte)- 00h- 01hDisable packet *Enable packet

. Warning

If you are using the SmartCradle to communicate with the Scanner, "BT Synchronization" command should be sent to the scanner after the setting of the "Dollar Sign Control" and "Data Transmission Packet" to sync the Scanner with the SmartCradle, so that the settings will take effect immediately.

Parameter(s)

< Table 6-4-3 > Reply BT Operation Parameter(s) Field (Continued)

Parameter / PID / Size Options Descriptions
UPC/EAN Security LevelPID: 02h 06hSize: 00h 01h (1 Byte)- 00h- 01h- 02hLevel 0Level 1 *Level 2
Supplement Scan VotingPID: 02h 08hSize: 00h 01h (1 Byte)- 00h- 06h- 08h- 0Ah- 0Ch- 0Eh- 10h- 12h- 14h- 16h- 18h- 1Ah- 1Ch- 1EhNoneLevel 1Level 2Level 3 *Level 4Level 5Level 6Level 7Level 8Level 9Level 10Level 11Level 12Level 13
Operation Mode(Bluetooth F & L Series)PID: 50h 00hSize: 00h 01h (1 Byte)- 00h- 02hTrigger mode (External triggering) *Presentation mode (Auto Detection)
Batch Scanning Link ControlPID: 51h 00hSize: 00h 01h (1 Byte)- 00h- 01hRadio DisableRadio Enable *
Stored Data TransmissionPID: 51h 01hSize: 00h 01h (1 Byte)- 00h- 01h- 02hAll *On-cradleScan Barcode
Delete Stored Data AfterTransmissionPID: 51h 02hSize: 00h 01h (1 Byte)- 00h- 01hDisable *Enable
Field DelimiterPID: 51h 03hSize: 00h 01h (1 Byte)- 00h- 2Ch- 20h- 2Dh- 2Eh- XXhNone<,> *User-defined 00~7Fh<-><.->
Batch Data Quantity OutputFormatPID: 51h 04hSize: 00h 01h (1 Byte)- 00h- 01h- 02hAs many times as the quantity indicates *

. Warning

If you are using the SmartCradle to communicate with the Scanner, "BT Synchronization" command should be sent to the scanner after the setting of the "Field Delimiter" to sync the Scanner with the SmartCradle, so that the settings will take effect immediately.

Parameter(s)

< Table 6-4-3 > Reply BT Operation Parameter(s) Field (Continued)

Parameter / PID / Size Options Descriptions
Laser Aiming ControlPID : 02h 09hSize : 00h 01h (1 Byte)- 00h- 01hDisableEnable *
LED IlluminationPID : 02h 0BhSize : 00h 01h (1 Byte)- 00h- 01hAlways onIntelligent Scanning *
Illumination Delay DurationPID : 02h 0ChSize : 00h 01h (1 Byte)- 00h- 01h- 02h- 03h- 04h100ms200ms300ms400ms500ms
Operation Mode(Bluetooth A Series)PID : 70h 00hSize : 00h 03h (3 Bytes)- 00h 01h 01h- 02h 01h 01hTrigger mode *Presentation mode
Hand-Held Mode Illumination& Aiming ControlPID : 70h 01hSize : 00h 01h (1 Byte)Bit 0- 0- 1Bit 1- 0- 1Hand-Held Decode Aiming ControlDisableEnable *Hand-Held Illumination ControlDisableEnable *
Hand-Free Mode DecodeAiming ControlPID : 70h 02hSize : 00h 01h (1 Byte)- 02h- 03hDisableEnable *
Aiming ControlPID : 70h 03hSize : 00h 02h (2 Bytes)- 00h 00h- 01h 00h- 00h 03hRegular Aiming *Intelligent AimingDelay Aiming Control

.Notes

  1. LED Illumination, Illumination Delay Duration are only available for L680BT, L688BT, L780BT, L788BT.
  2. Laser Aiming Control is only available for L688BT, L788BT
  3. Hand-Held Mode Illumination & Aiming Control, Hand-Free Mode Decode Aiming Control and Aiming Control are available for A Series only.

Parameter(s)

< Table 6-1-1 > Set BT Operation Parameter(s) Field (Continued)

Parameter / PID / Size Options Descriptions
Delay Aiming TimeoutControlPID : 70h 04hSize : 00h 01h (1 Byte)- 02h- 04h- 08h- 0Ah- 0Fh- 14h- 1Eh- 28h200ms400ms *800ms1000ms1500ms2000ms3000ms4000ms
Presentation BackgroundLightingPID : 70h 05hSize : 00h 02h (2 Bytes)- 00h 00h- 00h FFhLEDs OffLEDs On *
Center AlignmentPID : 70h 06hSize : 00h 02h (2 Bytes)1st Byte- 00h- 01h2nd Byte- 00h- 01hHand-Held ModeDisable *EnableHand-Free ModeDisable *Enable
Mobile Phone CapturePID : 70h 07hSize : 00h 01h (1 Byte)- 00h- 01hDisable *Enable

Notes

Delay Aiming Timeout, Presentation Background Lighting, Center Alignment and Mobile Phone Capture are available for A Series only.

Set WF Operation (WF)

Descriptions

Change the desired one or more parameters of the Operation Settings for Wi-Fi Scanner.

Available for F & L series

Packet Format

PrefixOpcodeStatusLengthParameter(s)LRCSuffix
7Eh88h00h00hVariableSee Below Variable7Eh
1 Byte3Bytes1 Byte2 Bytes/Variable1 Byte 1 Byte
Parameter(s)
First Parameter ......Last Parameter
PIDSizeOptions......PIDSizeOptions
2 Bytes2 BytesVariable......2 Bytes2 BytesVariable
See Next Page

. Host Requirements

If the device successfully received the above command issued by the host, a "Device ACK" will send to the host right after the device performed the action. Otherwise, a "Device NAK" will be sent to host to issue a command error. However, if the host can not receive any response from the device within the user preset time-out duration, please resend the above command.

. Parameter(s) Field

Set SE Operation can change multiple parameters at one time, so it takes compound parameters.

. Length

Total size (bytes) of the Parameter(s) field

.LRC

"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"

. Size

Total size (bytes) of the Options field

Parameter(s)

< Table 6-5-1 > Set WF Operation Parameter(s) Field (To be continued)

Parameter / PID / Size Options Descriptions
Power Saving TimeoutPID: 00h 09hSize: 00h 01h (1 Byte)- 00h- 01h- 02h- 03h- 04h- 05h1 second5 seconds *10 seconds20 seconds30 secondsImmediately
Buzzer Tone AdjustPID: 01h 00hSize: 00h 02h (2 Bytes) 1^st 2^nd Byte- 00h 00h- 01h 01h- 01h 02h- 01h 03h- 01h 04hMuteLowMedium *HighExtremely High
Power on beepPID: 01h 01hSize: 00h 01h (1 Byte)- 00h- 01hEnable *Disable
Power on IndicationPID: 01h 02hSize: 00h 01h (1 Byte)- 00h- 01h- 02hDisable (LED off)LED steady on *LED flash
VibratorPID: 01h 03hSize: 00h 01h (1 Byte)- 00h- 01hDisable *Enable
1D Barcode Inverse ReadingPID: 02h 00hSize: 00h 01h (1 Byte)- 00h- 01hDisable *Enable
Dollar Sign ControlPID: 02h 01hSize: 00h 01h (1 Byte)- 00h- 80h- A2h- A3h- A5hOutput as “$” *Output as “€”Output as “¢”Output as “£”Output as “¥”
RedundancyPID: 02h 02hSize: 00h 01h (1 Byte)- 00h- 01h- 02h- 03h- 04h- 05hNoneLevel 1 *Level 2Level 3Level 4Level 5
Good Read DelayPID: 00h 06hSize: 00h 01h (1 Byte)- 00h- 01h- 02h- 03h- 04h- 05h- 06hNone*200 ms500 ms1 s1.5 s2 s3 s
Good Read DurationPID: 01h 04hSize: 00h 01h (1 Byte)- 00h- 01h- 02h- 03h- 04hShortMedium *LongExtremely longExtremely short
Good Read IndicatorPID: 01h 05hSize: 00h 01h (1 Byte)- 00h- 01hDisableEnable *

Parameter(s)

< Table 6-5-1 > Set WF Operation Parameter(s) Field (Continued)

Parameter / PID / Size Options Descriptions
Beeping ControlPID : 01h 06hSize : 00h 01h (1 Byte)Bit 0- 0- 1Bit 1- 0- 1Radio Connection BeepEnable *DisableBattery Power Low BeepEnable *Disable
Scan Rate ControlPID : 00h 0BhSize : 00h 01h (1 Byte)- 00h- 01hDynamic *Fixed
Laser Aiming ControlPID : 02h 09hSize : 00h 01h (1 Byte)- 00h- 01hDisableEnable *
LED IlluminationPID : 02h 0BhSize : 00h 01h (1 Byte)- 00h- 01hAlways onIntelligent Scanning *
Illumination Delay DurationPID : 02h 0ChSize : 00h 01h (1 Byte)- 00h- 01h- 02h- 03h- 04h100ms200ms300ms400ms500ms

. Note

  1. Laser Aiming Control is only available for L788WD
  2. LED Illumination, Illumination Delay Duration are only available for L780WD, L788WD

Get WF Operation (WF)

Descriptions

Request the desired one or more parameters of the Operation Settings for Wi-Fi Scanner Available for F & L series

Packet Format

PrefixOpcodeStatusLengthParameter(s)LRCSuffix
7EhC9h00h00hVariableSee BelowVariable7Eh
1 Byte3Bytes1 Byte2 BytesVariable1 Byte1 Byte
Parameter(s)
First Parameter......Last Parameter
PID Size ......PID Size
2 Bytes2 Bytes......2 Bytes2 Bytes
See Next Page

. Host Requirements

If the device successfully received the above command issued by the host, the device will pack all requested parameters into a "Reply SE Operation" message string then send to the host. Please refer to the "Reply SE Operation" command for details. Otherwise, a "Device NAK" will be sent to host to indicate issue a command error. However, if the host can receive any response from the device within the user preset time-out duration, please resend the above command.

. Parameter(s) Field

Get SE Operation can request multiple parameters at one time, so it takes compound parameters.

. Length

Total size (bytes) of the Parameter(s) field

.LRC

"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"

. Size

Total size (bytes) of the Options field

Parameter(s)

< Table 6-5-2 > Get WF Operation Parameter(s) Field

Parameter PID Size
Power Saving Timeout 00h 09h00h 00h
Buzzer Tone Adjust 01h 00h00h 00h
Power on beep 01h 01h00h 00h
Power on Indication 01h 02h00h 00h
Vibrator 01h 03h00h 00h
1D Barcode Inverse Reading 02h 00h00h 00h
Dollar Sign Control 02h 01h00h 00h
Redundancy 02h 02h00h 00h
Good Read Delay 00h 06h00h 00h
Good Read Duration01h 04h00h 00h
Good Read Indicator01h 05h00h 00h
Beeping Control01h 06h00h 00h
Scan Rate Control00h 0Bh00h 00h
Laser Aiming Control02h 09h00h 00h
LED Illumination02h 0Bh00h 00h
Illumination Delay Duration02h 0Ch00h 00h

Reply WF Operation (WF)

Descriptions

Reply the desired one or more parameters of the Operation Settings for Wi-Fi Scanner Reply WF Operation is sent by the device in response to the Get WF Operation command. It sends the values for all the desired parameters requested in the Get WF Operation command. Available for F & L series

Packet Format

PrefixOpcodeStatusLengthParameter(s)LRCSuffix
7Eh0Ah00h00hVariableSee BelowVariable7Eh
1 Byte3Bytes1 Byte2 BytesVariable1 Byte1 Byte
Parameter(s)
First Parameter......Last Parameter
PIDSizeOptions......PIDSizeOptions
2 Bytes2 BytesVariable......2 Bytes2 BytesVariable
See Next Page
Parameter(s)
First Parameter......Last Parameter
PIDSizeOptions......PIDSizeOptions
2 Bytes2 BytesVariable......2 Bytes2 BytesVariable
See Next Page

. Host Requirements

Since Reply SE Operation is a device-to-host message, there is no response for this message.

. Parameter(s) Field

Set SE Operation can change multiple parameters at one time, so it takes compound parameters.

. Length

Total size (bytes) of the Parameter(s) field

.LRC

"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"

. Size

Total size (bytes) of the Options field

Parameter(s)

< Table 6-5-3 > Reply WF Operation Parameter(s) Field (To be continued)

Parameter / PID / Size Options Descriptions
Power Saving TimeoutPID : 00h 09hSize : 00h 01h (1 Byte)- 00h- 01h- 02h- 03h- 04h- 05h1 second5 seconds *10 seconds20 seconds30 secondsImmediately
Buzzer Tone AdjustPID : 01h 00hSize : 00h 02h (2 Bytes) 1^st 2^nd Byte- 00h 00h- 01h 01h- 01h 02h- 01h 03h- 01h 04hMuteLowMedium *HighExtremely High
Power on beepPID : 01h 01hSize : 00h 01h (1 Byte)- 00h- 01hEnable *Disable
Power on IndicationPID : 01h 02hSize : 00h 01h (1 Byte)- 00h- 01h- 02hDisable (LED off)LED steady on *LED flash
VibratorPID : 01h 03hSize : 00h 01h (1 Byte)- 00h- 01hDisable *Enable
1D Barcode Inverse ReadingPID : 02h 00hSize : 00h 01h (1 Byte)- 00h- 01hDisable *Enable
Dollar Sign ControlPID : 02h 01hSize : 00h 01h (1 Byte)- 00h- 80h- A2h- A3h- A5hOutput as “$” *Output as “€”Output as “¢”Output as “£”Output as “¥”
RedundancyPID : 02h 02hSize : 00h 01h (1 Byte)- 00h- 01h- 02h- 03h- 04h- 05hNoneLevel 1 *Level 2Level 3Level 4Level 5
Good Read DelayPID : 00h 06hSize : 00h 01h (1 Byte)- 00h- 01h- 02h- 03h- 04h- 05h- 06hNone*200 ms500 ms1 s1.5 s2 s3 s
Good Read DurationPID : 01h 04hSize : 00h 01h (1 Byte)- 00h- 01h- 02h- 03h- 04hShortMedium *LongExtremely longExtremely short
Good Read IndicatorPID : 01h 05hSize : 00h 01h (1 Byte)- 00h- 01hDisableEnable *

Parameter(s)

< Table 6-5-3 > Reply WF Operation Parameter(s) Field (Continued)

Parameter / PID / Size Options Descriptions
Beeping ControlPID : 01h 06hSize : 00h 01h (1 Byte)Bit 0- 0- 1Bit 1- 0- 1Radio Connection BeepEnable *DisableBattery Power Low BeepEnable *Disable
Scan Rate ControlPID : 00h 0BhSize : 00h 01h (1 Byte)- 00h- 01hDynamic *Fixed
Laser Aiming ControlPID : 02h 09hSize : 00h 01h (1 Byte)- 00h- 01hDisable *Enable
LED IlluminationPID : 02h 0BhSize : 00h 01h (1 Byte)- 00h- 01hAlways on Intelligent Scanning *
Illumination Delay DurationPID : 02h 0ChSize : 00h 01h (1 Byte)- 00h- 01h- 02h- 03h- 04h100ms200ms300ms400ms500ms

. Note

  1. Laser Aiming Control is only available for L788WD
  2. LED Illumination, Illumination Delay Duration are only available for L780WD, L788WD

Command Descriptions

Set WF System (WF)

Descriptions

Change the desired one or more parameters of the System Settings for Wi-Fi Scanner.

Available for F & L series

Packet Format

PrefixOpcodeStatusLengthParameter(s)LRCSuffix
7EhA1h 00h 00h00h VariableSee Below Variable7Eh
1 Byte3Bytes1 Byte2 BytesVariable1 Byte1 Byte
Parameter(s)
First Parameter ......Last Parameter
PIDSizeOptions......PIDSizeOptions
2 Bytes2 BytesVariable......2 Bytes2 BytesVariable
See Next Page

. Host Requirements

If the device successfully received the above command issued by the host, a "Device ACK" will send to the host right after the device performed the action. Otherwise, a "Device NAK" will be sent to host to issue a command error. However, if the host can not receive any response from the device within the user preset time-out duration, please resend the above command.

. Parameter(s) Field

Set SE Operation can change multiple parameters at one time, so it takes compound parameters.

. Length

Total size (bytes) of the Parameter(s) field

.LRC

"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"

. Size

Total size (bytes) of the Options field

Parameter(s)

< Table 6-6-1 > Set WF System Parameter(s) Field (To be continued)

Parameter / PID / Size Options Descriptions
Wi-Fi Device NamePID : 00h 00hSize : 00h 11h (17 Bytes) 1^st Byte- XXh 2^nd 17^th Byte- XXh XXh...XXhTotal number of the Device Name in charactersUser defined 1~16 character(s) (See Note)
Admin PasswordPID : 00h 01hSize : 00h 04h (4 Bytes)- 00h 00h 00h00h- XXh XXh...XXhDefault *User defined 4 digits (See Note)
User PasswordPID : 00h 02hSize : 00h 04h (4 Bytes)- 00h 00h 00h00h-XXh XXh...XXhDefault *User defined 4 digits (See Note)
User Available FunctionsPID : 00h 03hSize : 00h 01h (3 Bytes) 1^st Byte- 00h- 01h 2^nd Byte- 00h- 01h 3^rd Byte- 00h- 01hOnline ModeDisableEnable *Batch ModeDisableEnable *ToolsDisableEnable *
BrightnessPID : 00h 04hSize : 00h 01h (1 Byte)- 00h- 01hHigh *Low
Backlight DurationPID : 00h 05hSize : 00h 01h (1 Byte)- 05h- 0Ah- 0Fh- 14h- 19h- 1Eh- 2Dh- 3Ch5 seconds10 seconds15 seconds20 seconds25 seconds30 seconds *45 seconds60 seconds
Key TonesPID : 00h 06hSize : 00h 01h (1 Byte)- 00h- 01h- 02h- 03h- 04hExtremely High *HighMediumLowMute
Wake Up KeyPID : 00h 07hSize : 00h 01h (1 Byte)- 00h- 01hTrigger *Trigger + R

.Notes

  1. Device Name: If the desired ASCII characters are shorter than 16 bytes, the rest bytes should be set to 00h. To set to default device name, this parameter should be set to: 00h FFh...FFh (sixteen "FFh"s)
  2. Admin Password/ User Password should be set to four 0\~9 digit numbers, because the password Keyboard is preset to Numeric Keyboard, and you can only enter digit number.

Command Descriptions

Get WF System (WF)

Descriptions

Request the desired one or more parameters of the System Settings for Wi-Fi Scanner Available for F & L series

Packet Format

PrefixOpcodeStatusLengthParameter(s)LRCSuffix
7EhE2h00h00hVariableSee BelowVariable7Eh
1 Byte3Bytes1 Byte2 BytesVariable1 Byte1 Byte
Parameter(s)
First Parameter......Last Parameter
PID SizePID Size
2 Bytes2 Bytes......2 Bytes2 Bytes
See Next Page

. Host Requirements

If the device successfully received the above command issued by the host, the device will pack all requested parameters into a "Reply WF System" message string then send to the host. Please refer to the "Reply WF System" command for details. Otherwise, a "Device NAK" will be sent to host to indicate issue a command error. However, if the host can receive any response from the device within the user preset time-out duration, please resend the above command.

. Parameter(s) Field

Get SE Operation can request multiple parameters at one time, so it takes compound parameters.

. Length

Total size (bytes) of the Parameter(s) field

.LRC

"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"

. Size

Total size (bytes) of the Options field

Parameter(s)

< Table 6-6-2 > Get WF System Parameter(s) Field

Parameter PID Size
Wi-Fi Device Name 00h 00h00h 00h
Admin Password 00h 01h00h 00h
User Password 00h 02h00h 00h
User Available Functions 00h 03h00h 00h
Brightness 00h 04h00h 00h
Backlight Duration 00h 05h00h 00h
Key Tones 00h 06h00h 00h
Wake Up Key 00h 07h00h 00h

Reply WF System (WF)

Descriptions

Reply the desired one or more parameters of the System Settings for Wi-Fi Scanner Reply WF System is sent by the device in response to the Get WF System command. It sends the values for all the desired parameters requested in the Get WF System command. Available for F & L series

Packet Format

PrefixOpcodeStatusLengthParameter(s)LRCSuffix
7Eh23h00h00hVariableSee BelowVariable7Eh
1 Byte3Bytes1 Byte2 BytesVariable1 Byte1 Byte
Parameter(s)
First Parameter......Last Parameter
PIDSizeOptions......PIDSizeOptions
2 Bytes2 BytesVariable......2 Bytes2 BytesVariable
See Next Page

. Host Requirements

Since Reply SE Operation is a device-to-host message, there is no response for this message.

. Parameter(s) Field

Set SE Operation can change multiple parameters at one time, so it takes compound parameters.

. Length

Total size (bytes) of the Parameter(s) field

.LRC

"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"

. Size

Total size (bytes) of the Options field

Parameter(s)

< Table 6-6-3 > Reply WF System Parameter(s) Field (To be continued)

Parameter / PID / Size Options Descriptions
Wi-Fi Device NamePID : 00h 00hSize : 00h 11h (17 Bytes) 1^st Byte- XXh 2^nd 17^th Byte- XXh XXh...XXhTotal number of the Device Name in charactersUser defined 1~16 character(s) (See Note)
Admin PasswordPID : 00h 01hSize : 00h 04h (4 Bytes)- 00h 00h 00h00h- XXh XXh...XXhDefault *User defined 4 digits
User PasswordPID : 00h 02hSize : 00h 04h (4 Bytes)- 00h 00h 00h00h-XXh XXh...XXhDefault *User defined 4 digits
User Available FunctionsPID : 00h 03hSize : 00h 01h (3 Bytes) 1^st Byte- 00h- 01h 2^nd Byte- 00h- 01h 3^rd Byte- 00h- 01hOnline ModeDisableEnable *Batch ModeDisableEnable *ToolsDisableEnable *
BrightnessPID : 00h 04hSize : 00h 01h (1 Byte)- 00h- 01hHigh *Low
Backlight DurationPID : 00h 05hSize : 00h 01h (1 Byte)- 05h- 0Ah- 0Fh- 14h- 19h- 1Eh- 2Dh- 3Ch5 seconds10 seconds15 seconds20 seconds25 seconds30 seconds *45 seconds60 seconds
Key TonesPID : 00h 06hSize : 00h 01h (1 Byte)- 00h- 01h- 02h- 03h- 04hExtremely High *HighMediumLowMute
Wake Up KeyPID : 00h 07hSize : 00h 01h (1 Byte)- 00h- 01hTrigger *Trigger + R

Set WF Scanning (WF)

Descriptions

Change the desired one or more parameters of the Scanning Settings for Wi-Fi Scanner.

Available for F & L series

Packet Format

PrefixOpcodeStatusLengthParameter(s)LRCSuffix
7Eh9Eh00h00hVariableSee Below Variable7Eh
1 Byte3Bytes1 Byte2 Bytes/Variable1 Byte
Parameter(s)
First Parameter ......Last Parameter
PIDSizeOptions......PIDSizeOptions
2 Bytes2 BytesVariable......2 Bytes2 BytesVariable
See Next Page

. Host Requirements

If the device successfully received the above command issued by the host, a "Device ACK" will send to the host right after the device performed the action. Otherwise, a "Device NAK" will be sent to host to issue a command error. However, if the host can not receive any response from the device within the user preset time-out duration, please resend the above command.

. Parameter(s) Field

Set SE Operation can change multiple parameters at one time, so it takes compound parameters.

. Length

Total size (bytes) of the Parameter(s) field

.LRC

"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"

. Size

Total size (bytes) of the Options field

Parameter(s)

< Table 6-7-1 > Set WF Scanning Parameter(s) Field (To be continued)

Parameter / PID / Size Options Descriptions
Barcode TypePID : 00h 00hSize : 00h 01h (1 Byte)- 00h- 01hDisableEnable *
Font SizePID : 00h 01hSize : 00h 01h (1 Byte)- 00h- 01hCompact *Normal
Record SuffixPID : 00h 02hSize : 00h 02h (2 Bytes) 1^st 2^nd Byte- FFh FFh- 0Dh FFh- 0Ah FFh- 0Dh 0Ah- 09h FFh- 20h FFh- 04h FFh- XXh FFhNoneCR *LF *CRLFTABSPACEEOTUser defined ASCII value
Host ACKPID : 00h 03hSize : 00h 01h (1 Byte)- 00h- 01hDisableEnable *
Transmission FormatPID : 00h 04hSize : 00h 01h (1 Byte)- 00h- 01hRaw Data *Packet Data
Host ACK TimeoutPID : 00h 05hSize : 00h 01h (1 Byte)- 01h- 04h- 09h- 0Fh- 12h- 24h- 4Fh- 50h- 48h- 56h- 5Ah- 61hNone200 mseconds500 mseconds800 mseconds1 second *2 seconds3 seconds4 seconds5 seconds8 seconds10 seconds15 seconds
ACK IndicationPID : 00h 07hSize : 00h 01h (1 Byte)Bit 0- 0h- 1hBit 1- 0h- 1hTransmission Timeout IndicationDisableEnable *ACK IndicationDisableEnable *
Field DelimiterPID : 00h 09hSize : 00h 01h (1 Byte)- 2Ch- XXh,*User defined ASCII value
Record DelimiterPID : 00h 0AhSize : 00h 01h (1 Byte)- 0Dh- XXh[CR] *User defined ASCII value
Timestamp FormatPID : 00h 0BhSize : 00h 01h (1 Byte)- 00h- 01h- 02h- 03h- 04h- 05hhh:mm dd/mm/yyyy *hh:mm mm/dd/yyyyhh:mm yyyy/mm/dddd/mm/yyyy hh:mmmm/dd/yyyy hh:mmyyyy/mm/dd hh:mm

Parameter(s)

< Table 6-7-1 > Set WF Scanning Parameter(s) Field (Continued)

Parameter / PID / Size Options Descriptions
Auto Save
PID : 00h 0Ch- 00hDisable
Size : 00h 01h (1 Byte)- 01hEnable with tip
- 02hEnable without tip *
Link Control
PID : 00h 0Dh- 00hRadio Disable
Size : 00h 01h (1 Byte)- 01hRadio Enable *
Delete Stored Data
PID : 00h 0Eh- 00hDisable *
Size : 00h 01h (1 Byte)- 01hEnable
Data Transmission
PID : 00h 0Fh- 00hVia Wi-Fi *
Size : 00h 01h (1 Byte)- 01hVia USB HID
- 02hVia USB COM

Get WF Scanning (WF)

Descriptions

Request the desired one or more parameters of the Scanning Settings for Wi-Fi Scanner Available for F & L series

Packet Format

PrefixOpcodeStatusLengthParameter(s)LRCSuffix
7EhDFh00h 00h00hVariableSee BelowVariable7Eh
1 Byte3Bytes1 Byte2 BytesVariable1 Byte1 Byte
Parameter(s)
First Parameter......Last Parameter
PID Size ......PID Size
2 Bytes2 Bytes......2 Bytes2 Bytes
See Next Page

. Host Requirements

If the device successfully received the above command issued by the host, the device will pack all requested parameters into a "Reply WF Scanning" message string then send to the host. Please refer to the "Reply WF Scanning" command for details. Otherwise, a "Device NAK" will be sent to host to indicate issue a command error. However, if the host can receive any response from the device within the user preset time-out duration, please resend the above command.

. Parameter(s) Field

Get SE Operation can request multiple parameters at one time, so it takes compound parameters.

. Length

Total size (bytes) of the Parameter(s) field

.LRC

"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"

. Size

Total size (bytes) of the Options field

Parameter(s)

< Table 6-7-2 > Get WF Scanning Parameter(s) Field

Parameter PID Size
Barcode Type 00h 00h00h 00h
Font Size 00h 01h00h 00h
Record Suffix 00h 02h00h 00h
Host ACK 00h 03h00h 00h
Transmission Format 00h 04h00h 00h
Host ACK Timeout 00h 05h00h 00h
ACK Indication 00h 07h00h 00h
Field Delimiter 00h 09h00h 00h
Record Delimiter 00h 0Ah00h 00h
Timestamp Format 00h 0Bh00h 00h
Auto Save00h 0Ch00h 00h
Link Control00h 0Dh00h 00h
Delete Stored Data00h 0Eh00h 00h
Data Transmission00h 0Fh00h 00h

Reply WF Scanning (WF)

Descriptions

Reply the desired one or more parameters of the Scanning Settings for Wi-Fi Scanner Reply WF Scanning is sent by the device in response to the Get WF Scanning command. It sends the values for all the desired parameters requested in the Get WF Scanning command. Available for F & L series

Packet Format

PrefixOpcodeStatusLengthParameter(s)LRCSuffix
7Eh20h00h00hVariableSee BelowVariable7Eh
1 Byte3Bytes1 Byte2 BytesVariable1 Byte1 Byte
Parameter(s)
First Parameter......Last Parameter
PIDSizeOptions......PIDSizeOptions
2 Bytes2 BytesVariable......2 Bytes2 BytesVariable
See Next Page

. Host Requirements

Since Reply SE Operation is a device-to-host message, there is no response for this message.

. Parameter(s) Field

Set SE Operation can change multiple parameters at one time, so it takes compound parameters.

. Length

Total size (bytes) of the Parameter(s) field

.LRC

"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"

. Size

Total size (bytes) of the Options field

Parameter(s)

< Table 6-7-3 > Reply WF Scanning Parameter(s) Field (To be continued)

Parameter / PID / Size Options Descriptions
Barcode TypePID : 00h 00hSize : 00h 01h (1 Byte)- 00h- 01hDisableEnable *
Font SizePID : 00h 01hSize : 00h 01h (1 Byte)- 00h- 01hCompact *Normal
Record SuffixPID : 00h 02hSize : 00h 02h (2 Bytes) 1^st 2^nd Byte- FFh FFh- 0Dh FFh- 0Ah FFh- 0Dh 0Ah- 09h FFh- 20h FFh- 04h FFh- XXh FFhNoneCR *LF *CRLFTABSPACEEOTUser defined ASCII value
Host ACKPID : 00h 03hSize : 00h 01h (1 Byte)- 00h- 01hDisableEnable *
Transmission FormatPID : 00h 04hSize : 00h 01h (1 Byte)- 00h- 01hRaw Data *Packet Data
Host ACK TimeoutPID : 00h 05hSize : 00h 01h (1 Byte)- 01h- 04h- 09h- 0Fh- 12h- 24h- 4Fh- 50h- 48h- 56h- 5Ah- 61hNone200 mseconds500 mseconds800 mseconds1 second *2 seconds3 seconds4 seconds5 seconds8 seconds10 seconds15 seconds
ACK IndicationPID : 00h 07hSize : 00h 01h (1 Byte)Bit 0- 0h- 1hBit 1- 0h- 1hTransmission Timeout IndicationDisableEnable *ACK IndicationDisableEnable *
Field DelimiterPID : 00h 09hSize : 00h 01h (1 Byte)- 2Ch- XXh,*User defined ASCII value
Record DelimiterPID : 00h 0AhSize : 00h 01h (1 Byte)- 0Dh- XXh[CR] *User defined ASCII value
Timestamp FormatPID : 00h 0BhSize : 00h 01h (1 Byte)- 00h- 01h- 02h- 03h- 04h- 05hhh:mm dd/mm/yyyy *hh:mm mm/dd/yyyyhh:mm yyyy/mm/dddd/mm/yyyy hh:mmmm/dd/yyyy hh:mmyyyy/mm/dd hh:mm

Parameter(s)

< Table 6-7-3 > Reply WF Scanning Parameter(s) Field (Continued)

Parameter / PID / Size Options Descriptions
Auto Save
PID : 00h 0Ch- 00hDisable
Size : 00h 01h (1 Byte)- 01hEnable with tip
- 02hEnable without tip *
Link Control
PID : 00h 0Dh- 00hRadio Disable
Size : 00h 01h (1 Byte)- 01hRadio Enable *
Delete Stored Data
PID : 00h 0Eh- 00hDisable *
Size : 00h 01h (1 Byte)- 01hEnable
Data Transmission
PID : 00h 0Fh- 00hVia Wi-Fi *
Size : 00h 01h (1 Byte)- 01hVia USB HID
- 02hVia USB COM

2.7 Transmission

Set Transmission (ALL)

Descriptions

Change the desired one or more parameters of the Transmission settings as well as DataWizard Premium parameters including Data Script Active Setting, Data Script Setting, Security Script Setting and Data Wizard Premium Error Message.

DataWizard Premium parameters are only available for Scanners that support DataWizard Premium. For more details about DataWizard Premium, please refer to FuzzyScan DataWizard Premium User Manual.

Packet Format

PrefixOpcodeStatusLengthParameter(s)LRCSuffix
7Eh8Bh00h 00h00h VariableSee Below Variable7Eh
1 Byte3Bytes1 Byte2 BytesVariable1 Byte
Parameter(s)
First Parameter......Last Parameter
PIDSizeOptions......PIDSize OOptions
2 Bytes2 BytesVariable......2 Bytes2 BytesVariable
See Next Page

. Host Requirements

If the device successfully received the above command issued by the host, a "Device ACK" will send to the host right after the device performed the action. Otherwise, a "Device NAK" will be sent to host to issue a command error. However, if the host can not receive any response from the device within the user preset time-out duration, please resend the above command.

. Parameter(s) Field

Set Transmission can change multiple parameters at one time, so it takes compound parameters.

. Length

Total size (bytes) of the Parameter(s) field

.LRC

"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"

. Size

Total size (bytes) of the Options field

Parameter(s)

< Table 7-1-1 > Set Transmission Parameter(s) Field (To be continued)

Parameter / PID / Size Options Descriptions
Interface Delay SettingsPID : 00h 00hSize : 00h 03h (3 Bytes) 1^st Byte- 00h- 01h~63h 2^nd Byte- 00h- 01h~63h 3^rd Byte- 00h- 01h~63hIntermessage DelayNone *1~99(×5)msIntercharacter DelayNone *1~99(×5)msInterfunction DelayNone *1~99(×5)ms
Record Suffix (KB)PID : 01h 00hSize : 00h 02h (2 Bytes) 1^st ~ 2^nd Byte- FFh FFh- 0Dh FFh- 09h FFh- 20h FFh- FEh FFh- XXh FFhNoneCR (0Dh) *TAB (09h)SPACE (20h)ENTER (Numeric Key Pad)User-defined one ASCII character (XXh)
Record Suffix (Serial)PID : 01h 00hSize : 00h 02h (2 Bytes) 1^st ~ 2^nd Byte- FFh FFh- 0Dh FFh- 0Ah FFh- 0Dh 0Ah- 09h FFh- 20h FFh- XXh FFhNoneCR (0Dh) *LF (0Ah)CR (0Dh) LF (0Ah)TAB (09h)SPACE (20h)User-defined one ASCII character (XXh)
PreamblePID : 01h 01hSize : 00h 10h (16 Bytes) 1^st Byte- XXh 2^nd ~ 16^th Byte- XXh XXh...XXhTotal number of the Preamble characters1~15 character(s) (See Note)
PostamblePID : 01h 02hSize : 00h 10h (16 Bytes) 1^st Byte- XXh 2^nd ~ 16^th Byte- XXh XXh...XXhTotal number of the Postamble characters1~15 character(s) (See Note)
Symbol ID TransmissionPID : 01h 03hSize : 00h 01h (1 Byte)- 00h- 01h- 02h- 03h- 04h- 05h- 06hDisable *Enable prefix IDEnable suffix IDEnable both prefix and suffix IDEnable prefix AIM IDEnable suffix AIM IDEnable both prefix and suffix AIM ID

.Notes

  1. Intercharacter Delay, Interfunction Delay settings are not available for serial communications via USB Virtual COM port.
  2. Preamble/ Postamble 2^nd 16^th byte: If the desired ASCII characters for setting the Preamble/ Postamble are shorter than 15 bytes, the rest bytes should be set to 00h.

Parameter(s)

< Table 7-1-1 > Set Transmission Parameter(s) Field (Continued)

Parameter / PID / Size Options Descriptions
Data Script Active SettingPID : 02h 00hSize : 00h 01h (1 Byte)- 01h- 02h......- 10h(See Note)Active 1st Data Script *Active 2nd Data Script......Active 16th Data Script
Data Script SettingPID : 02h 01hSize : 00h 01h (1 Byte)Bit 1- 0- 1Bit 0, Bit 2 ~ 7Data Script (See Note)Disable *EnableReserved
Security Script SettingPID : 02h 02hSize : 00h 01h (1 Byte)- 00h- 01h(See Note)Disable Security Script *Enable Security Script
DataWizard Premium Error MessagePID : 02h 03hSize : 00h 01h (1 Byte)- 00h- 01h(See Note)Disable Error Message *Enable Error Message

.Notes

  1. Data Script Active Setting, Data Script Setting, Security Script Setting and Data Wizard Premium Error Message are all DataWizard Premium parameters which are available for Scanners that support DataWizard Premium. For more details about DataWizard Premium, please refer to FuzzyScan DataWizard Premium User Manual.

Get Transmission (ALL)

Descriptions

Request the desired one or more parameters of the Transmission settings as well as DataWizard Premium parameters including Data Script Active Setting, Data Script Setting, Security Script Setting and Data Wizard Premium Error Message.

DataWizard Premium parameters are only available for Scanners that support DataWizard Premium. For more details about DataWizard Premium, please refer to FuzzyScan DataWizard Premium User Manual.

Packet Format

PrefixOpcodeStatusLengthParameter(s)LRCSuffix
7EhCCh00h00hVariableSee BelowVariable7Eh
1 Byte3Bytes1 Byte2 BytesVariable1 Byte1 Byte
Parameter(s)
First Parameter......Last Parameter
PID Size......PID Size
2 Bytes2 Bytes......2 Bytes2 Bytes
See Next Page

. Host Requirements

If the device successfully received the above command issued by the host, the device will pack all requested parameters into a "Reply Transmission" message string then send to the host. Please refer to the "Reply Transmission" command for details. Otherwise, a "Device NAK" will be sent to host to indicate issue a command error. However, if the host can receive any response from the device within the user preset time-out duration, please resend the above command.

. Parameter(s) Field

Get Transmission can request multiple parameters at one time, so it takes compound parameters.

. Length

Total size (bytes) of the Parameter(s) field

.LRC

"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"

. Size

Total size (bytes) of the Options field

Parameter(s)

< Table 7-1-2 > Get Transmission Parameter(s) Field

Parameter PID Size
Interface Delay Settings 00h 00h00h 00h
Record Suffix 01h 00h00h 00h
Preamble 01h 01h00h 00h
Postamble 01h 02h00h 00h
Symbology ID Transmission 01h 03h00h 00h
Data Script Active Setting 02h 00h00h 00h
Data Script Setting 02h 01h00h 00h
Security Script Setting 02h 02h00h 00h
DataWizard Premium Error Message 02h 03h00h 00h

Reply Transmission (ALL)

Descriptions

Reply the desired one or more parameters of the Transmission settings as well as DataWizard Premium parameters including Data Script Active Setting, Data Script Setting, Security Script Setting and Data Wizard Premium Error Message.

Reply Transmission is sent by the device in response to the Get Transmission command. It sends the values for all the desired parameters requested in the Get Transmission command.

DataWizard Premium parameters are only available for Scanners that support DataWizard Premium. For more details about DataWizard Premium, please refer to FuzzyScan DataWizard Premium User Manual.

Packet Format

PrefixOpcodeStatusLengthParameter(s)LRCSuffix
7Eh0Dh00h 00h00hVariableSee Below Variable7Eh
1 Byte3Bytes1 Byte2 BytesVariable1 Byte1 Byte
Parameter(s)
First Parameter......Last Parameter
PIDSizeOptions......PIDSizeOptions
2 Bytes2 BytesVariable......2 Bytes2 BytesVariable
See Next Page

. Host Requirements

Since Reply Transmission is a device-to-host message, there is no response for this message.

. Parameter(s) Field

Reply Transmission can change multiple parameters at one time, so it takes compound parameters.

. Length

Total size (bytes) of the Parameter(s) field

.LRC

"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"

. Size

Total size (bytes) of the Options field

Parameter(s)

< Table 7-1-3 > Reply Transmission Parameter(s) Field

Parameter / PID / Size Options Descriptions
Interface Delay SettingsPID : 00h 00hSize : 00h 03h (3 Bytes) 1^st Byte- 00h- 01h~63h 2^nd Byte- 00h- 01h~63h 3^rd Byte- 00h- 01h~63hIntermessage DelayNone *1~99(×5)msIntercharacter DelayNone *1~99(×5)msInterfunction DelayNone *1~99(×5)ms
Record Suffix (KB)PID : 01h 00hSize : 00h 02h (2 Bytes) 1^st ~ 2^nd Byte- FFh FFh- 0Dh FFh- 09h FFh- 20h FFh- FEh FFh- XXh FFhNoneCR (0Dh) *TAB (09h)SPACE (20h)ENTER (Numeric Key Pad)User-defined one ASCII character (XXh)
Record Suffix (Serial)PID : 01h 00hSize : 00h 02h (2 Bytes) 1^st ~ 2^nd Byte- FFh FFh- 0Dh FFh- 0Ah FFh- 0Dh 0Ah- 09h FFh- 20h FFh- XXh FFhNoneCR (0Dh) *LF (0Ah)CR (0Dh) LF (0Ah)TAB (09h)SPACE (20h)User-defined one ASCII character (XXh)
PreamblePID : 01h 01hSize : 00h 10h (16 Bytes) 1^st Byte- XXh 2^nd ~ 16^th Byte- XXh XXh...XXhTotal number of the Preamble characters1~15 character(s) (See Note)
PostamblePID : 01h 02hSize : 00h 10h (16 Bytes) 1^st Byte- XXh 2^nd ~ 16^th Byte- XXh XXh...XXhTotal number of the Postamble characters1~15 character(s) (See Note)
Symbol ID TransmissionPID : 01h 03hSize : 00h 01h (1 Byte)- 00h- 01h- 02h- 03h- 04h- 05h- 06hDisable *Enable prefix IDEnable suffix IDEnable both prefix and suffix IDEnable prefix AIM IDEnable suffix AIM IDEnable both prefix and suffix AIM ID

Notes

  1. Intercharacter Delay, Interfunction Delay settings are not available for serial communications via USB Virtual COM port.
  2. Preamble/ Postamble: If the desired ASCII characters for setting the Preamble/ Postamble are shorter than 15 bytes, the rest bytes should be set to 00h.

Parameter(s)

< Table 7-1-3 > Reply Transmission Parameter(s) Field (Continued)

Parameter / PID / Size Options Descriptions
Data Script Active SettingPID : 02h 00hSize : 00h 01h (1 Byte)- 01h- 02h......- 10h(See Note)Active 1st Data Script *Active 2nd Data Script......Active 16th Data Script
Data Script SettingPID : 02h 01hSize : 00h 01h (1 Byte)Bit 1- 0- 1Bit 0, Bit 2 ~ 7Data Script (See Note)Disable *EnableReserved
Security Script SettingPID : 02h 02hSize : 00h 01h (1 Byte)- 00h- 01h(See Note)Disable Security Script *Enable Security Script
DataWizard Premium Error MessagePID : 02h 03hSize : 00h 01h (1 Byte)- 00h- 01h(See Note)Disable Error Message *Enable Error Message

.Notes

  1. Data Script Active Setting, Data Script Setting, Security Script Setting and Data Wizard Premium Error Message are all DataWizard Premium parameters which are available for Scanners that support DataWizard Premium. For more details about DataWizard Premium, please refer to FuzzyScan DataWizard Premium User Manual.

Set Transmission (WF)

Descriptions

Change the desired one or more parameters of the Transmission settings as well as DataWizard Premium parameters including Data Script Active Setting, Data Script Setting, Security Script Setting and Data Wizard Premium Error Message.

Available for F & L series

Note that DataWizard Premium parameters are only available for Scanners that support DataWizard Premium. For more details about DataWizard Premium, please refer to FuzzyScan DataWizard Premium User Manual.

Packet Format

PrefixOpcodeStatusLengthParameter(s)LRCSuffix
7Eh8Bh00h00hVariableSee BelowVariable7Eh
1 Byte3Bytes1 Byte2 BytesVariable1 Byte1 Byte
Parameter(s)
First Parameter......Last Parameter
PIDSizeOptions......PIDSizeOptions
2 Bytes2 BytesVariable......2 Bytes2 BytesVariable
See Next Page

. Host Requirements

If the device successfully received the above command issued by the host, a "Device ACK" will send to the host right after the device performed the action. Otherwise, a "Device NAK" will be sent to host to issue a command error. However, if the host can not receive any response from the device within the user preset time-out duration, please resend the above command.

. Parameter(s) Field

Set Transmission can change multiple parameters at one time, so it takes compound parameters.

.Length

Total size (bytes) of the Parameter(s) field

.LRC

"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"

. Size

Total size (bytes) of the Options field

Parameter(s)

< Table 7-1-1 > Set Transmission Parameter(s) Field

Parameter / PID / Size Options Descriptions
Interface Delay SettingsPID : 00h 00hSize : 00h 03h (3 Bytes) 1^st Byte- 00h- 01h~63h 2^nd Byte- 00h- 01h~63h 3^rd Byte- 00h- 01h~63hIntermessage DelayNone *1~99(×5)msIntercharacter DelayNone *1~99(×5)msInterfunction DelayNone *1~99(×5)ms
PreamblePID : 01h 01hSize : 00h 10h (16 Bytes) 1^st Byte- XXh 2^nd ~ 16^th Byte- XXh XXh...XXhTotal number of the Preamble characters1~15 character(s) (See Note)
PostamblePID : 01h 02hSize : 00h 10h (16 Bytes) 1^st Byte- XXh 2^nd ~ 16^th Byte- XXh XXh...XXhTotal number of the Postamble characters1~15 character(s) (See Note)
Symbol ID TransmissionPID : 01h 03hSize : 00h 01h (1 Byte)- 00h- 01h- 02h- 03h- 04h- 05h- 06hDisable *Enable prefix IDEnable suffix IDEnable both prefix and suffix IDEnable prefix AIM IDEnable suffix AIM IDEnable both prefix and suffix AIM ID

.Notes

  1. Intercharacter Delay, Interfunction Delay settings are not available for serial communications via USB Virtual COM port.
  2. Preamble/ Postamble 2^nd 16^th byte: If the desired ASCII characters for setting the Preamble/ Postamble are shorter than 15 bytes, the rest bytes should be set to 00h.

Parameter(s)

< Table 7-1-1 > Set Transmission Parameter(s) Field (Continued)

Parameter / PID / Size Options Descriptions
Data Script Active SettingPID : 02h 00hSize : 00h 01h (1 Byte)- 01h- 02h......- 10h(See Note)Active 1st Data Script *Active 2nd Data Script......Active 16th Data Script
Data Script SettingPID : 02h 01hSize : 00h 01h (1 Byte)Bit 1- 0- 1Bit 0, Bit 2 ~ 7Data Script (See Note)Disable *EnableReserved
Security Script SettingPID : 02h 02hSize : 00h 01h (1 Byte)- 00h- 01h(See Note)Disable Security Script *Enable Security Script
DataWizard Premium Error MessagePID : 02h 03hSize : 00h 01h (1 Byte)- 00h- 01h(See Note)Disable Error Message *Enable Error Message

.Notes

  1. Data Script Active Setting, Data Script Setting, Security Script Setting and Data Wizard Premium Error Message are all DataWizard Premium parameters which are available for Scanners that support DataWizard Premium. For more details about DataWizard Premium, please refer to FuzzyScan DataWizard Premium User Manual.

Get Transmission (WF)

Descriptions

Request the desired one or more parameters of the Transmission settings as well as DataWizard Premium parameters including Data Script Active Setting, Data Script Setting, Security Script Setting and Data Wizard Premium Error Message.

Available for F & L series

Note that DataWizard Premium parameters are only available for Scanners that support DataWizard Premium. For more details about DataWizard Premium, please refer to FuzzyScan DataWizard Premium User Manual.

Packet Format

PrefixOpcodeStatusLengthParameter(s)LRCSuffix
7EhCCh00h00hVariableSee BelowVariable7Eh
1 Byte3Bytes1 Byte2 BytesVariable1 Byte1 Byte
Parameter(s)
First Parameter......Last Parameter
PID Size......PID Size
2 Bytes2 Bytes......2 Bytes2 Bytes
See Next Page

. Host Requirements

If the device successfully received the above command issued by the host, the device will pack all requested parameters into a "Reply Transmission" message string then send to the host. Please refer to the "Reply Transmission" command for details. Otherwise, a "Device NAK" will be sent to host to indicate issue a command error. However, if the host can receive any response from the device within the user preset time-out duration, please resend the above command.

. Parameter(s) Field

Get Transmission can request multiple parameters at one time, so it takes compound parameters.

. Length

Total size (bytes) of the Parameter(s) field

.LRC

"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"

. Size

Total size (bytes) of the Options field

Parameter(s)

< Table 7-1-2 > Get Transmission Parameter(s) Field

Parameter PID Size
Interface Delay Settings 00h 00h00h 00h
Preamble 01h 01h00h 00h
Postamble 01h 02h00h 00h
Symbology ID Transmission 01h 03h00h 00h
Data Script Active Setting 02h 00h00h 00h
Data Script Setting 02h 01h00h 00h
Security Script Setting 02h 02h00h 00h
DataWizard Premium Error Message 02h 03h00h 00h

Reply Transmission (WF)

Descriptions

Reply the desired one or more parameters of the Transmission settings as well as DataWizard Premium parameters including Data Script Active Setting, Data Script Setting, Security Script Setting and Data Wizard Premium Error Message.

Reply Transmission is sent by the device in response to the Get Transmission command. It sends the values for all the desired parameters requested in the Get Transmission command.

Available for F & L series

Note that DataWizard Premium parameters are only available for Scanners that support DataWizard Premium. For more details about DataWizard Premium, please refer to FuzzyScan DataWizard Premium User Manual.

Packet Format

PrefixOpcode Status LengthParameter(s) LRC Suffix
7Eh0Dh 00h 00h00h VariableSee Below Variable7Eh
1 Byte3 Bytes1 Byte2 BytesVariable1 Byte1 Byte
Parameter(s)
First Parameter......Last Parameter
PIDSizeOptions......PIDSizeOptions
2 Bytes2 BytesVariable......2 Bytes2 BytesVariable
See Next Page

. Host Requirements

Since Reply Transmission is a device-to-host message, there is no response for this message.

. Parameter(s) Field

Reply Transmission can change multiple parameters at one time, so it takes compound parameters.

. Length

Total size (bytes) of the Parameter(s) field

.LRC

"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"

. Size

Total size (bytes) of the Options field

Parameter(s)

< Table 7-1-3 > Reply Transmission Parameter(s) Field (To be continued)

Parameter / PID / Size Options Descriptions
Interface Delay SettingsPID : 00h 00hSize : 00h 03h (3 Bytes) 1^st Byte- 00h- 01h~63h 2^nd Byte- 00h- 01h~63h 3^rd Byte- 00h- 01h~63hIntermessage DelayNone *1~99(×5)msIntercharacter DelayNone *1~99(×5)msInterfunction DelayNone *1~99(×5)ms
PreamblePID : 01h 01hSize : 00h 10h (16 Bytes) 1^st Byte- XXh 2^nd ~ 16^th Byte- XXh XXh...XXhTotal number of the Preamble characters1~15 character(s) (See Note)
PostamblePID : 01h 02hSize : 00h 10h (16 Bytes) 1^st Byte- XXh 2^nd ~ 16^th Byte- XXh XXh...XXhTotal number of the Postamble characters1~15 character(s) (See Note)
Symbol ID TransmissionPID : 01h 03hSize : 00h 01h (1 Byte)- 00h- 01h- 02h- 03h- 04h- 05h- 06hDisable *Enable prefix IDEnable suffix IDEnable both prefix and suffix IDEnable prefix AIM IDEnable suffix AIM IDEnable both prefix and suffix AIM ID

.Notes

  1. Intercharacter Delay, Interfunction Delay settings are not available for serial communications via USB Virtual COM port.
  2. Preamble/ Postamble: If the desired ASCII characters for setting the Preamble/ Postamble are shorter than 15 bytes, the rest bytes should be set to 00h.

Parameter(s)

< Table 7-1-3 > Reply Transmission Parameter(s) Field (Continued)

Parameter / PID / Size Options Descriptions
Data Script Active SettingPID : 02h 00hSize : 00h 01h (1 Byte)- 01h- 02h......- 10h(See Note)Active 1st Data Script *Active 2nd Data Script......Active 16th Data Script
Data Script SettingPID : 02h 01hSize : 00h 01h (1 Byte)Bit 1- 0- 1Bit 0, Bit 2 ~ 7Data Script (See Note)Disable *EnableReserved
Security Script SettingPID : 02h 02hSize : 00h 01h (1 Byte)- 00h- 01h(See Note)Disable Security Script *Enable Security Script
DataWizard Premium Error MessagePID : 02h 03hSize : 00h 01h (1 Byte)- 00h- 01h(See Note)Disable Error Message *Enable Error Message

.Notes

  1. Data Script Active Setting, Data Script Setting, Security Script Setting and Data Wizard Premium Error Message are all DataWizard Premium parameters which are available for Scanners that support DataWizard Premium. For more details about DataWizard Premium, please refer to FuzzyScan DataWizard Premium User Manual.

2.8 Symbology

Set Symbology (ALL)

Descriptions

Change the desired one or more parameters of the Symbology settings

Packet Format

PrefixOpcodeStatusLengthParameter(s)LRCSuffix
7Eh85h00h00hVariableSee BelowVariable7Eh
1 Byte3Bytes1 Byte2 BytesVariable1 Byte1 Byte
Parameter(s)
First Parameter ......Last Parameter
PIDSizeOptions......PIDSizeOptions
2 Bytes2 BytesVariable......2 Bytes2 BytesVariable
See Next Page

. Host Requirements

If the device successfully received the above command issued by the host, a "Device ACK" will send to the host right after the device performed the action. Otherwise, a "Device NAK" will be sent to host to issue a command error. However, if the host can not receive any response from the device within the user preset time-out duration, please resend the above command.

. Parameter(s) Field

Set Symbology can change multiple parameters at one time, so it takes compound parameters.

. Length

Total size (bytes) of the Parameter(s) field

.LRC

"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"

. Size

Total size (bytes) of the Options field

Parameter(s)

< Table 8-1-1 > Set Symbology Parameter(s) Field (To be continued)

Parameter / PID / Size Options Descriptions
Code 39 ReadabilityPID : 00h 00hSize : 00h 01h (1 Byte)- 00h- 01hDisableEnable *
Code 39 SettingPID : 00h 01hSize : 00h 06h (6 Bytes) 1^st Byte- 00h- 01h- 02h 2^nd Byte- 00h- 01h 3^rd Byte- 00h- 01h 4^th Byte- 00h- 01h 5^th Byte- 00h- 01h 6^th Byte- 00h- 01hPrimary Format SelectionStandard Code 39 *Full ASCII Code 39Code 32 (Italian Pharmaceutical)Start/ Stop Symbol TransmissionDisable *EnableCode 32 Leading A TransmissionDisable *EnableMOD 43 Check Digit VerificationDisable *EnableCheck Digit TransmissionDisable *EnableCode 39 BufferingDisable *Enable
Code 39 LengthPID : 00h 02hSize : 00h 02h (2 Bytes) 1^st Byte- 01h~62h 2^nd Byte- 62h~01hMinimum Length1~98 (Default: 1)Maximum Length98~1 (Default: 98)
Trioptic Code 39 ReadabilityPID : 00h 03hSize : 00h 01h (1 Byte)- 00h- 01hDisable *Enable
Code 39 Security LevelPID : 00h 04hSize : 00h 01h (1 Byte)- 00h- 01h- 02h- 03hLevel 0Level 1Level 2 *Level 3

Parameter(s)

< Table 8-1-1 > Set Symbology Parameter(s) Field (Continued)

Parameter / PID / Size Options Descriptions
Codabar ReadabilityPID : 01h 00hSize : 00h 01h (1 Byte)- 00h- 01hDisableEnable *
Codabar SettingsPID : 01h 01hSize : 00h 04h (4 Bytes) 1^st Byte- 00h- 01h- 02h- 03h 2^nd Byte- 00h- 01h- 02h- 03h- 04h 3^rd Byte- 00h- 01h 4^th Byte- 00h- 01hPrimary Format SelectionCodabar Standard format *Codabar ABC formatCodabar CLSI formatCodabar CX formatStart/ Stop Symbol TransmissionDisable *Enable ABCD/ABCDEnable abcd/abcdEnable ABCD/TN*EEnable abcd/tn*eCheck Digit VerificationDisable *EnableCheck Digit TransmissionDisable *Enable
Codabar LengthPID : 01h 02hSize : 00h 02h (2 Bytes) 1^st Byte- 01h~62h 2^nd Byte- 62h~01hMinimum Length1~98 (Default: 4)Maximum Length98~1 (Default: 98)
Codabar Check DigitPID : 01h 03hSize : 00h 01h (1 Byte)- 00h- 01h- 02h- 03h- 04h- 05h- 06hModulus 16*Modulus 10/Weight 3Modulus 11Modulus 10/Weight 27 Check DRWeight Modulus 11Runes (Modulus 10/Weight 2)

Parameter(s)

< Table 8-1-1 > Set Symbology Parameter(s) Field (Continued)

Parameter / PID / Size Options Descriptions
UPC-A/UPC-E ReadabilityPID: 02h 00hSize: 00h 02h (2 Bytes) 1^st Byte- 00h- 01h 2^nd Byte- 00h- 01hUPC-A ReadabilityDisableEnable *UPC-E ReadabilityDisableEnable *
UPC-A/UPC-E SettingPID: 02h 01hSize: 00h 06h (6 Bytes) 1^st Byte- 00h- 01h 2^nd Byte- 00h- 01h 3^rd Byte- 00h- 01h 4^th Byte- 00h- 01h 5^th Byte- 00h- 01h 6^th Byte- 00h- 01hUPC-E ExpansionDisable *EnableUPC StandardizationDisable *EnableUPC Numeric SystemDisableEnable *UPC-A Check Digit TransmissionDisableEnable *UPC-E Check Digit TransmissionDisableEnable *UPC "leading 1" PortionDisable *Enable
UPC-A/UPC-E SupplementPID: 02h 02hSize: 00h 03h (3 Bytes) 1^st Byte- 00h- 01h- 02h- 03h 2^nd Byte- 00h- 01h 3^rd Byte- 00h- 01hSupplement Digits SelectionWithout *With only 2 supplement digitsWith only 5 supplement digitsWith 2/5 supplement digitsForce Supplement Digits OutputDisable *EnableUPC Family Addenda SeparatorDisable *Enable

Parameter(s)

< Table 8-1-1 > Set Symbology Parameter(s) Field (Continued)

Parameter / PID / Size Options Descriptions
EAN-13/EAN-8 ReadabilityPID : 03h 00hSize : 00h 02h (2 Bytes) 1^st Byte- 00h- 01h 2^nd Byte- 00h- 01hEAN/JAN-13 ReadabilityDisableEnable *EAN/JAN-8 ReadabilityDisableEnable *
EAN-13/EAN-8 SettingPID : 03h 01hSize : 00h 04h (4 Bytes) 1^st Byte- 00h- 01h 2^nd Byte- 00h- 01h 3^rd Byte- 00h- 01h 4^th Byte- 00h- 01hEAN-8 ExpansionDisable *EnableEAN-13 Check Digit TransmissionDisableEnable *EAN-8 Check Digit TransmissionDisableEnable *ISBN/ISSN Reading CheckDisable *Enable
EAN-13/EAN-8 SupplementPID : 03h 02hSize : 00h 03h (3 Bytes) 1^st Byte- 00h- 01h- 02h- 03h 2^nd Byte- 00h- 01h 3^rd Byte- 00h- 01hSupplement Digits SelectionWithout *With only 2 supplement digitsWith only 5 supplement digitsWith 2/5 supplement digitsForce Supplement Digits OutputDisable *EnableEAN Family Addenda SeparatorDisable *Enable
EAN Supplement ControlPID : 03h 04hSize : 00h 01h (1 Byte)- 00h- 01h- 02h- 03h- 04h- 05h- 06h- 07hDisable All Specific Prefix Supplement Output *Enable All Specific Prefix Supplement OutputEnable 491 Supplement OutputEnable 978/979 Supplement OutputEnable 977 Supplement OutputEnable 378/379 Supplement OutputEnable 414/419 Supplement OutputEnable 434/439 Supplement Output
UCC Coupon Extended Code ReadabilityPID : 03h 03hSize : 00h 01h (1 Byte)- 00h- 01hDisable*Enable

Parameter(s)

< Table 8-1-1 > Set Symbology Parameter(s) Field (Continued)

Parameter / PID / Size Options Descriptions
IATA ReadabilityPID: 04h 00hSize: 00h 01h (1 Byte)- 00h- 01hDisable *Enable
IATA SettingPID: 04h 01hSize: 00h 04h (4 Bytes) 1^st Byte- 00h- 01h 2^nd Byte- 00h- 01h- 02h- 03h- 04h 3^rd Byte- 00h- 01h 4^th Byte- 00h- 01hIATA Checking Selection15-digit fixed length IATA checking*Variable length IATA checkingCheck Digit VerificationDisable *check digit automatic verificationS/N checking digit verification onlyCPN checking digit verification onlyCPN, Airline and S/N check digit verificationCheck Digit TransmissionDisable*EnableStart/Stop Symbol TransmissionDisable *Enable
Interleaved 2 of 5 ReadabilityPID: 04h 02hSize: 00h 01h (1 Byte)- 00h- 01hDisableEnable *
Interleaved 2 of 5 SettingsPID: 04h 03hSize: 00h 03h (3 Bytes) 1^st Byte- 00h- 01h 2^nd Byte- 00h- 01h- 02h 3^rd Byte- 00h- 01hDecoding Format SelectionInterleaved 2 of 5 *German Postal CodeUSS/OPCC Check Digit VerificationDisable *USS check digitOPCC check digitCheck Digit TransmissionDisable *Enable
Standard/Industrial 2 of 5 ReadabilityPID: 04h 04hSize: 00h 01h (1 Byte)- 00h- 01hDisable *Enable
Matrix 2 of 5 ReadabilityPID: 04h 05hSize: 00h 01h (1 Byte)- 00h- 01hDisable *Enable
China Postal Code ReadabilityPID: 04h 06hSize: 00h 01h (1 Byte)- 00h- 01hDisable *Enable

Parameter(s)

< Table 8-1-1 > Set Symbology Parameter(s) Field (To be continued)

Parameter / PID / Size Options Descriptions
Code 25 SettingPID:04h 07hSize:00h 02h (2 Bytes) 1^st Byte-00h-01h 2^nd Byte-00h-01hCheck Digit VerificationDisable *EnableCheck Digit TransmissionDisable *Enable
Code 25 LengthPID:04h 08hSize:00h 02h (2 Bytes) 1^st Byte-01h~62h 2^nd Byte-62h~01hMinimum Length1~98 (Default: 4)Maximum Length98~1 (Default: 98)
Code 11 ReadabilityPID:05h 00hSize:00h 01h (1 Byte)-00h-01hDisable *Enable
Code 11 SettingPID:05h 01hSize:00h 02h (2 Bytes) 1^st Byte-00h-01h-02h 2^nd Byte-00h-01hCheck Digit VerificationDisable *1-check digit verification2-check digit verificationCheck Digit TransmissionDisable *Enable
Code 11 LengthPID:05h 02hSize:00h 02h (2 Bytes) 1^st Byte-01h~62h 2^nd Byte-62h~01hMinimum Length1~98 (Default: 4)Maximum Length98~1 (Default: 98)
Code 93 ReadabilityPID:06h 00hSize:00h 01h (1 Byte)-00h-01hDisableEnable *
Code 93 Check Digit TransmissionPID:06h 01hSize:00h 01h (1 Byte)-00h-01hDisable *Enable
Code 93 LengthPID:06h 02hSize:00h 02h (2 Bytes) 1^st Byte-01h~62h 2^nd Byte-62h~01hMinimum Length1~98 (Default: 1)Maximum Length98~1 (Default: 98)

Parameter(s)

< Table 8-1-1 > Set Symbology Parameter(s) Field (Continued)

Parameter / PID / Size Options Descriptions
MSI/Plessey ReadabilityPID : 07h 00hSize : 00h 01h (1 Byte)- 00h- 01hDisable *Enable
MSI/Plessey SettingPID : 07h 01hSize : 00h 02h (2 Bytes) 1^st Byte- 00h- 01h- 02h 2^nd Byte- 00h- 01hCheck Digit SelectionMOD 10 check digit *MOD 10-10 check digitMOD 11-10 check digitCheck Digit TransmissionDisable *Enable
MSI/Plessey LengthPID : 07h 02hSize : 00h 02h (2 Bytes) 1^st Byte- 01h~62h 2^nd Byte- 62h~01hMinimum Length1~98 (Default: 4)Maximum Length98~1 (Default: 98)
Code 128/EAN-128 ReadabilityPID : 08h 00hSize : 00h 01h (1 Byte)- 00h- 01hDisableEnable *
Code 128/EAN-128 SettingPID : 08h 01hSize : 00h 01 (1 Byte)- 00h- 01hISBT Concatenation Off *ISBT Concatenation On
Code 128/EAN-128 LengthPID : 08h 02hSize : 00h 02h (2 Bytes) 1^st Byte- 01h~62h 2^nd Byte- 62h~01hMinimum Length1~98 (Default: 1)Maximum Length98~1 (Default: 98)
Code 128/EAN-128 Security LevelPID : 08h 03hSize : 00h 01h (1 Byte)- 00h- 01hLevel 0Level 1 *
GS1-128 ReadabilityPID : 08h 04hSize : 00h 01h (1 Byte)- 00h- 01hDisableEnable *
GS1-128 LengthPID : 08h 05hSize : 00h 02h (2 Bytes) 1^st Byte- 01h~62h 2^nd Byte- 62h~01hMinimum Length1~98 (Default: 1)Maximum Length98~1 (Default: 98)

Parameter(s)

< Table 8-1-1 > Set Symbology Parameter(s) Field (Continued)

Parameter / PID / Size Options Descriptions
UK/Plessey ReadabilityPID: 09h 00hSize: 00h 01h (1 Byte)- 00h- 01hDisable *Enable
UK/Plessey SettingPID: 09h 01hSize: 00h 03h (3 Bytes) 1^st Byte- 00h- 01h 2^nd Byte- 00h- 01h 3^rd Byte- 00h- 01hPrimary Format SelectionStandard *CLSIConvert X to A-FDisable *EnableCheck Digit TransmissionDisable *Enable
UK/Plessey LengthPID: 09h 02hSize: 00h 02h (2 Bytes) 1^st Byte- 01h~62h 2^nd Byte- 62h~01hMinimum Length1~98 (Default: 4)Maximum Length98~1 (Default: 98)
Telepen ReadabilityPID: 0Ah 00hSize: 00h 01h (1 Byte)- 00h- 01hDisable *Enable
Telepen SettingPID: 0Ah 01hSize: 00h 02h (2 Bytes) 1^st Byte- 00h- 01h 2^nd Byte- 00h- 01hPrimary Format SelectionTelepen Full ASCII modeTelepen Numeric mode *Check Digit TransmissionDisable *Enable
Telepen LengthPID: 0Ah 02hSize: 00h 02h (2 Bytes) 1^st Byte- 01h~62h 2^nd Byte- 62h~01hMinimum Length1~98 (Default: 4)Maximum Length98~1 (Default: 98)
GS 1 DataBar ReadabilityPID: 20h 00hSize: 00h 03h (3 Bytes) 1^st Byte- 00h- 01h 2^nd Byte- 00h- 01h 3^rd Byte- 00h- 01hGS1 DataBar (RSS-14)DisableEnable *GS1 DataBar LimitedDisableEnable *GS1 DataBar ExpandedDisableEnable *
GS 1 DataBar Expanded LengthPID: 20h 01hSize: 00h 02h (2 Bytes) 1^st Byte- 01h~4Ah 2^nd Byte- 4Ah~01hMinimum Length1~74 (Default: 4)Maximum Length74~1 (Default: 74)

Parameter(s)

< Table 8-1-1 > Set Symbology Parameter(s) Field (Continued)

Parameter / PID / Size Options Descriptions
Composite Code ReadabilityPID : 21h 00hSize : 00h 01h (1 Byte)- 00h- 01hDisable *Enable
UPC Composite ModePID : 21h 01hSize : 00h 01h (1 Byte)- 00h- 01hDisable *Enable
PDF417/ Micro PDF417ReadabilityPID : 22h 00hSize : 00h 02h (2 Bytes) 1^st Byte- 00h- 01h 2^nd Byte- 00h- 01hPDF417 ReadabilityDisableEnable *Micro PDF417 ReadabilityDisable *Enable
Codablock F ReadabilityPID : 23h 00hSize : 00h 01h (1 Byte)- 00h- 01hDisable *Enable
Code 16K ReadabilityPID : 24h 00hSize : 00h 01h (1 Byte)- 00h- 01hDisable *Enable
Code 16K LengthPID : 24h 01hSize : 00h 02h (2 Bytes) 1^st Byte- 01h~A0h 2^nd Byte- A0h~01hMinimum Length1~160 (Default: 1)Maximum Length160~1 (Default: 160)
Code 49 ReadabilityPID : 25h 00hSize : 00h 01h (1 Byte)- 00h- 01hDisable *Enable
Code 49 LengthPID : 25h 01hSize : 00h 02h (2 Bytes) 1^st Byte- 01h~51h 2^nd Byte- 51h~01hMinimum Length1~81 (Default: 1)Maximum Length81~1 (Default: 81)

Parameter(s)

< Table 8-1-1 > Set Symbology Parameter(s) Field (Continued)

Parameter / PID / Size Options Descriptions
QR Code ReadabilityPID : 30h 00hSize : 00h 01h (1 Byte)- 00h- 01hDisableEnable *
Micro QR Code ReadabilityPID : 30h 01hSize : 00h 01h (1 Byte)- 00h- 01hDisableEnable *
QR Code SettingPID : 30h 02hSize : 00h 02h (2 Bytes) 1^st Byte- 00h- 01h 2^nd Byte- 00h- 01h- 02hQR Code AppendDisableEnable *QR Code Inverse ReadingDisable *EnableAuto Detect
QR Code LengthPID : 30h 03hSize : 00h 04h (4 Bytes) 1^st & 2^nd Byte- 01h~1BB1h 3^rd & 4^th Byte- 1BB1h~01hMinimum Length(Big Endian)1~7089 (Default: 1)Maximum Length(Big Endian)7089~1 (Default: 7089)
Data Matrix ReadabilityPID : 31h 00hSize : 00h 01h (1 Byte)- 00h- 01hDisableEnable *
Data Matrix SettingPID : 31h 01hSize : 00h 02h (2 Bytes) 1^st Byte- 00h- 01h 2^nd Byte- 00h- 01h- 02hData Matrix AppendDisableEnable *Data Matrix Inverse ReadingDisable *EnableAuto Detect
Data Matrix LengthPID : 31h 02hSize : 00h 04h (4 Bytes) 1^st & 2^nd Byte- 01h~C2Ch 3^rd & 4^th Byte- C2Ch~01hMinimum Length(Big Endian)1~3116 (Default: 1)Maximum Length(Big Endian)3116~1 (Default: 3116)
MaxiCode ReadabilityPID : 32h 00hSize : 00h 01h (1 Byte)- 00h- 01hDisable *Enable
MaxiCode LengthPID : 32h 01hSize : 00h 02h (2 Bytes) 1^st Byte- 01h~96h 2^nd Byte- 96h~01hMinimum Length1~150 (Default: 1)Maximum Length150~1 (Default: 150)

Parameter(s)

< Table 8-1-1 > Set Symbology Parameter(s) Field (Continued)

Parameter / PID / Size Options Descriptions
Aztec ReadabilityPID : 33h 00hSize : 00h 01h (1 Byte)- 00h- 01hDisable *Enable
Aztec SettingPID : 33h 01hSize : 00h 02h (2 Bytes) 1^st Byte- 00h- 01h 2^nd Byte- 00h- 01h- 02hAztec AppendDisable *EnableAztec Inverse ReadingDisable *EnableAuto Detect
Aztec LengthPID : 33h 02hSize : 00h 04h (4 Bytes) 1^st & 2^nd Byte- 01h~EF8h 3^rd & 4^th Byte- EF8h~01hMinimum Length(Big Endian)1~3832 (Default: 1)Maximum Length(Big Endian)3832 ~1 (Default: 3832)
Chinese Sensible ReadabilityPID : 34h 00hSize : 00h 01h (1 Byte)- 00h- 01hDisable *Enable
Chinese Sensible LengthPID : 34h 01hSize : 00h 04h (4 Bytes) 1^st & 2^nd Byte- 01h~1E99h 3^rd & 4^th Byte- 1E99h~01hMinimum Length(Big Endian)1~7833 (Default: 1)Maximum Length(Big Endian)7833~1 (Default: 7833)
Korea Post CodePID : 50h 00hSize : 00h 01h (1 Byte)- 00h- 01hDisable *Enable
Australian Post ReadabilityPID : 51h 00hSize : 00h 01h (1 Byte)- 00h- 01hDisable *Enable
Australian Post Output FormatPID : 51h 01hSize : 00h 03h (3 Bytes)- 00h FFh FFh- 00h 00h 00h- 00h 7Fh FFh- 01h 00h FFhRaw format Output *Numeric Encoding OutputAlphanumeric Encoding OutputAutodiscriminate Output
US Planet ReadabilityPID : 52h 00hSize : 00h 01h (1 Byte)- 00h- 01hDisable *Enable
US Planet Check DigitTransmissionPID : 52h 01hSize : 00h 01h (1 Byte)- 00h- 01hDisable *Enable

Parameter(s)

< Table 8-1-1 > Set Symbology Parameter(s) Field (Continued)

Parameter / PID / Size Options Descriptions
US Postnet ReadabilityPID : 53h 00hSize : 00h 01h (1 Byte)- 00h- 01hDisable *Enable
US Postnet Check Digit TransmissionPID : 53h 01hSize : 00h 01h (1 Byte)- 00h- 01hDisable *Enable
British Post ReadabilityPID : 54h 00hSize : 00h 01h (1 Byte)- 00h- 01hDisable *Enable
British Post Check Digit TransmissionPID : 54h 01hSize : 00h 01h (1 Byte)- 00h- 01hDisable *Enable
Japan Post ReadabilityPID : 55h 00hSize : 00h 01h (1 Byte)- 00h- 01hDisable *Enable
Netherlands KIX Code ReadabilityPID : 56h 00hSize : 00h 01h (1 Byte)- 00h- 01hDisable *Enable
Intelligent Mail ReadabilityPID : 57h 00hSize : 00h 01h (1 Byte)- 00h- 01hDisable *Enable

Get Symbology (ALL)

Descriptions

Request the desired one or more parameters of the Symbology settings

Packet Format

PrefixOpcodeStatusLengthParameter(s)LRCSuffix
7EhC6h00h00hVariableSee BelowVariable7Eh
1 Byte3Bytes1 Byte2 BytesVariable1 Byte1 Byte
Parameter(s)
First Parameter......Last Parameter
PID SizePID Size
2 Bytes2 Bytes......2 Bytes2 Bytes
See Next Page

. Host Requirements

If the device successfully received the above command issued by the host, the device will pack all requested parameters into a "Reply Symbology" message string then send to the host. Please refer to the "Reply Symbology" command for details. Otherwise, a "Device NAK" will be sent to host to indicate issue a command error. However, if the host can receive any response from the device within the user preset time-out duration, please resend the above command.

. Parameter(s) Field

Get Symbology can request multiple parameters at one time, so it takes compound parameters.

. Length

Total size (bytes) of the Parameter(s) field

.LRC

"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"

. Size

Total size (bytes) of the Options field

Parameter(s)

< Table 8-1-2 > Get Symbology Parameter(s) Field (To be continued)

Parameter PID Size
Code 39 Readability 00h 00h00h 00h
Code 39 Setting 00h 01h00h 00h
Code 39 Length 00h 02h00h 00h
Trioptic Code 39 Readability 00h 03h00h 00h
Code 39 Security Level 00h 04h00h 00h
Codabar Readability 01h 00h00h 00h
Codabar Settings 01h 01h00h 00h
Codabar Length 01h 02h00h 00h
Codabar Check Digit 01h 03h00h 00h
UPC-A/UPC-E Readability 02h 00h00h 00h
UPC-A/UPC-E Setting02h 01h00h 00h
UPC-A/UPC-E Supplement02h 02h00h 00h
EAN-13/EAN-8 Readability03h 00h00h 00h
EAN-13/EAN-8 Setting03h 01h00h 00h
EAN-13/EAN-8 Supplement03h 02h00h 00h
UCC Coupon Extended Code Readability03h 03h00h 00h
EAN Supplement Control03h 04h00h 00h
IATA Readability04h 00h00h 00h
IATA Setting04h 01h00h 00h
Interleaved 2 of 5 Readability04h 02h00h 00h
Interleaved 2 of 5 Settings04h 03h00h 00h
Standard/Industrial 2 of 5 Readability04h 04h00h 00h
Matrix 2 of 5 Readability04h 05h00h 00h
China Postal Code Readability04h 06h00h 00h
Code 25 Setting 04h 07h00h 00h
Code 25 Length 04h 08h00h 00h
Code 11 Readability05h 00h00h 00h
Code 11 Setting 05h 01h00h 00h
Code 11 Length05h 02h00h 00h
Code 93 Readability 06h 00h00h 00h
Code 93 Check Digit Transmission06h 01h00h 00h
Code 93 Length 06h 02h00h 00h
MSI/Plessey Readability07h 00h00h 00h
MSI/Plessey Setting07h 01h00h 00h
MSI/Plessey Length07h 02h00h 00h

Parameter(s)

< Table 8-1-2 > Get Symbology Parameter(s) Field (Continued)

Parameter PID Size
Code 128/EAN-128 Readability 08h 00h00h 00h
Code 128/EAN-128 Setting 08h 01h00h 00h
Code 128/EAN-128 Length 08h 02h00h 00h
Code 128/EAN-128 Security Level 08h 03h00h 00h
GS1-128 Readability 08h 04h00h 00h
GS1-128 Length 08h 05h00h 00h
UK/Plessey Readability 09h 00h00h 00h
UK/Plessey Setting 09h 01h00h 00h
UK/Plessey Length 09h 02h00h 00h
Telepen Readability0Ah 00h00h 00h
Telepen Setting0Ah 01h00h 00h
Telepen Length0Ah 02h00h 00h
GS 1 DataBar Readability20h 00h00h 00h
GS 1 DataBar Expanded Length20h 01h00h 00h
Composite Code Readability21h 00h00h 00h
UPC Composite Mode21h 01h00h 00h
PDF417/MicroPDF417 Readability 22h 00h00h 00h
Codablock F Readability23h 00h00h 00h
Code 16K Readability24h 00h00h 00h
Code 16K Length24h 01h00h 00h
Code 49 Readability25h 00h00h 00h
Code 49 Length25h 01h00h 00h
QR Code Readability30h 00h00h 00h
Micro QR Code Readability30h 01h00h 00h
QR Code Setting30h 02h00h 00h
QR Code Length30h 03h00h 00h
Data Matrix Readability31h 00h00h 00h
Data Matrix Setting31h 01h00h 00h
Data Matrix Length31h 02h00h 00h
MaxiCode Readability32h 00h00h 00h
MaxiCode Length32h 01h00h 00h
Aztec Code Readability 33h 00h00h 00h
Aztec Code Setting 33h 01h00h 00h
Aztec Code Length 33h 02h00h 00h

Parameter(s)

< Table 8-1-2 > Get Symbology Parameter(s) Field (Continued)

Parameter PID Size
Chinese Sensible Readability 34h 00h00h 00h
Chinese Sensible Length 34h 01h00h 00h
Korea Post Code 50h 00h00h 00h
Australian Post Readability 51h 00h00h 00h
Australian Post Output Format 51h 01h00h 00h
US Planet Readability 52h 00h00h 00h
US Planet Check Digit Transmission 52h 01h00h 00h
US Postnet Readability 53h 00h00h 00h
US Postnet Check Digit Transmission 53h 01h00h 00h
British Post Readability 54h 00h00h 00h
British Post Check Digit Transmission54h 01h00h 00h
Japan Post Readability 55h 00h00h 00h
Netherlands KIX Code Readability56h 00h00h 00h
Intelligent Mail Readability57h 00h00h 00h

Reply Symbology (ALL)

Descriptions

Reply the desired one or more parameters of the Symbology settings

Reply Symbology is sent by the device in response to the Get Symbology command. It sends the values for all the desired parameters requested in the Get Symbology command.

Packet Format

PrefixOpcodeStatusLengthParameter(s)LRCSuffix
7Eh07h00h00hVariableSee Below Variable7Eh
1 Byte3Bytes1 Byte2 Bytes/Variable 1 Byte1 Byte
Parameter(s)
First Parameter......Last Parameter
PIDSizeOptions......PIDSizeOptions
2 Bytes2 BytesVariable......2 Bytes2 BytesVariable
See Next Page

. Host Requirements

Since Reply Symbology is a device-to-host message, there is no response for this message.

. Parameter(s) Field

Set Symbology can change multiple parameters at one time, so it takes compound parameters.

. Length

Total size (bytes) of the Parameter(s) field

.LRC

"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"

. Size

Total size (bytes) of the Options field

Parameter(s)

< Table 8-1-3 > Reply Symbology Parameter(s) Field (To be continued)

Parameter / PID / Size Options Descriptions
Code 39 ReadabilityPID : 00h 00hSize : 00h 01h (1 Byte)- 00h- 01hDisableEnable *
Code 39 SettingPID : 00h 01hSize : 00h 06h (6 Bytes) 1^st Byte- 00h- 01h- 02h 2^nd Byte- 00h- 01h 3^rd Byte- 00h- 01h 4^th Byte- 00h- 01h 5^th Byte- 00h- 01h 6^th Byte- 00h- 01hPrimary Format SelectionStandard Code 39 *Full ASCII Code 39Code 32 (Italian Pharmaceutical)Start/ Stop Symbol TransmissionDisable *EnableCode 32 Leading A TransmissionDisable *EnableMOD 43 Check Digit VerificationDisable *EnableCheck Digit TransmissionDisable *EnableCode 39 BufferingDisable *Enable
Code 39 LengthPID : 00h 02hSize : 00h 02h (2 Bytes) 1^st Byte- 01h~62h 2^nd Byte- 62h~01hMinimum Length1~98 (Default: 1)Maximum Length98~1 (Default: 98)
Trioptic Code 39 ReadabilityPID : 00h 03hSize : 00h 01h (1 Byte)- 00h- 01hDisable *Enable
Code 39 Security LevelPID : 00h 04hSize : 00h 01h (1 Byte)- 00h- 01h- 02h- 03hLevel 0Level 1Level 2 *Level 3

Parameter(s)

< Table 8-1-3 > Reply Symbology Parameter(s) Field (Continued)

Parameter / PID / Size Options Descriptions
Codabar ReadabilityPID : 01h 00hSize : 00h 01h (1 Byte)- 00h- 01hDisableEnable *
Codabar SettingsPID : 01h 01hSize : 00h 04h (4 Bytes) 1^st Byte- 00h- 01h- 02h- 03h 2^nd Byte- 00h- 01h- 02h- 03h- 04h 3^rd Byte- 00h- 01h 4^th Byte- 00h- 01hPrimary Format SelectionCodabar Standard format *Codabar ABC formatCodabar CLSI formatCodabar CX formatStart/ Stop Symbol TransmissionDisable *Enable ABCD/ABCDEnable abcd/abcdEnable ABCD/TN*EEnable abcd/tn*eCheck Digit VerificationDisable *EnableCheck Digit TransmissionDisable *Enable
Codabar LengthPID : 01h 02hSize : 00h 02h (2 Bytes) 1^st Byte- 01h~62h 2^nd Byte- 62h~01hMinimum Length1~98 (Default: 4)Maximum Length98~1 (Default: 98)
Codabar Check DigitPID : 01h 03hSize : 00h 01h (1 Byte)- 00h- 01h- 02h- 03h- 04h- 05h- 06hModulus 16*Modulus 10/Weight 3Modulus 11Modulus 10/Weight 27 Check DRWeight Modulus 11Runes (Modulus 10/Weight 2)

Parameter(s)

< Table 8-1-3 > Reply Symbology Parameter(s) Field (Continued)

Parameter / PID / Size Options Descriptions
UPC-A/UPC-E ReadabilityPID: 02h 00hSize: 00h 02h (2 Bytes) 1^st Byte- 00h- 01h 2^nd Byte- 00h- 01hUPC-A ReadabilityDisableEnable *UPC-E ReadabilityDisableEnable *
UPC-A/UPC-E SettingPID: 02h 01hSize: 00h 06h (6 Bytes) 1^st Byte- 00h- 01h 2^nd Byte- 00h- 01h 3^rd Byte- 00h- 01h 4^th Byte- 00h- 01h 5^th Byte- 00h- 01h 6^th Byte- 00h- 01hUPC-E ExpansionDisable *EnableUPC StandardizationDisable *EnableUPC Numeric SystemDisableEnable *UPC-A Check Digit TransmissionDisableEnable *UPC-E Check Digit TransmissionDisableEnable *UPC "leading 1" PortionDisable *Enable
UPC-A/UPC-E SupplementPID: 02h 02hSize: 00h 03h (3 Bytes) 1^st Byte- 00h- 01h- 02h- 03h 2^nd Byte- 00h- 01h 3^rd Byte- 00h- 01hSupplement Digits SelectionWithout *With only 2 supplement digitsWith only 5 supplement digitsWith 2/5 supplement digitsForce Supplement Digits OutputDisable *EnableUPC Family Addenda SeparatorDisable *Enable

Parameter(s)

< Table 8-1-3 > Reply Symbology Parameter(s) Field (Continued)

Parameter / PID / Size Options Descriptions
EAN-13/EAN-8 ReadabilityPID: 03h 00hSize: 00h 02h (2 Bytes) 1^st Byte- 00h- 01h 2^nd Byte- 00h- 01hEAN/JAN-13 ReadabilityDisableEnable *EAN/JAN-8 ReadabilityDisableEnable *
EAN-13/EAN-8 SettingPID: 03h 01hSize: 00h 04h (4 Bytes) 1^st Byte- 00h- 01h 2^nd Byte- 00h- 01h 3^rd Byte- 00h- 01h 4^th Byte- 00h- 01hEAN-8 ExpansionDisable *EnableEAN-13 Check Digit TransmissionDisableEnable *EAN-8 Check Digit TransmissionDisableEnable *ISBN/ISSN Reading CheckDisable *Enable
EAN-13/EAN-8 SupplementPID: 03h 02hSize: 00h 03h (3 Bytes) 1^st Byte- 00h- 01h- 02h- 03h 2^nd Byte- 00h- 01h 3^rd Byte- 00h- 01hSupplement Digits SelectionWithout *With only 2 supplement digitsWith only 5 supplement digitsWith 2/5 supplement digitsForce Supplement Digits OutputDisable *EnableEAN Family Addenda SeparatorDisable *Enable
EAN Supplement ControlPID: 03h 04hSize: 00h 01h (1 Byte)- 00h- 01h- 02h- 03h- 04h- 05h- 06h- 07hDisable All Specific Prefix Supplement Output *Enable All Specific Prefix Supplement OutputEnable 491 Supplement OutputEnable 978/979 Supplement OutputEnable 977 Supplement OutputEnable 378/379 Supplement OutputEnable 414/419 Supplement OutputEnable 434/439 Supplement Output
UCC Coupon Extended Code ReadabilityPID: 03h 03hSize: 00h 01h (1 Byte)- 00h- 01hDisable*Enable

Parameter(s)

< Table 8-1-3 > Reply Symbology Parameter(s) Field (Continued)

Parameter / PID / Size Options Descriptions
IATA ReadabilityPID: 04h 00hSize: 00h 01h (1 Byte)- 00h- 01hDisable *Enable
IATA SettingPID: 04h 01hSize: 00h 04h (4 Bytes) 1^st Byte- 00h- 01h 2^nd Byte- 00h- 01h- 02h- 03h- 04h 3^rd Byte- 00h- 01h 4^th Byte- 00h- 01hIATA Checking Selection15-digit fixed length IATA checking*Variable length IATA checkingCheck Digit VerificationDisable *check digit automatic verificationS/N checking digit verification onlyCPN checking digit verification onlyCPN, Airline and S/N check digit verificationCheck Digit TransmissionDisable*EnableStart/Stop Symbol TransmissionDisable *Enable
Interleaved 2 of 5 ReadabilityPID: 04h 02hSize: 00h 01h (1 Byte)- 00h- 01hDisableEnable *
Interleaved 2 of 5 SettingsPID: 04h 03hSize: 00h 03h (3 Bytes) 1^st Byte- 00h- 01h 2^nd Byte- 00h- 01h- 02h 3^rd Byte- 00h- 01hDecoding Format SelectionInterleaved 2 of 5 *German Postal CodeUSS/OPCC Check Digit VerificationDisable *USS check digitOPCC check digitCheck Digit TransmissionDisable *Enable
Standard/Industrial 2 of 5 ReadabilityPID: 04h 04hSize: 00h 01h (1 Byte)- 00h- 01hDisable *Enable
Matrix 2 of 5 ReadabilityPID: 04h 05hSize: 00h 01h (1 Byte)- 00h- 01hDisable *Enable
China Postal Code ReadabilityPID: 04h 06hSize: 00h 01h (1 Byte)- 00h- 01hDisable *Enable

Parameter(s)

< Table 8-1-3 > Reply Symbology Parameter(s) Field (To be continued)

Parameter / PID / Size Options Descriptions
Code 25 SettingPID:04h 07hSize:00h 02h (2 Bytes) 1^st Byte-00h-01h 2^nd Byte-00h-01hCheck Digit VerificationDisable *EnableCheck Digit TransmissionDisable *Enable
Code 25 LengthPID:04h 08hSize:00h 02h (2 Bytes) 1^st Byte-01h~62h 2^nd Byte-62h~01hMinimum Length1~98 (Default: 4)Maximum Length98~1 (Default: 98)
Code 11 ReadabilityPID:05h 00hSize:00h 01h (1 Byte)-00h-01hDisable *Enable
Code 11 SettingPID:05h 01hSize:00h 02h (2 Bytes) 1^st Byte-00h-01h-02h 2^nd Byte-00h-01hCheck Digit VerificationDisable *1-check digit verification2-check digit verificationCheck Digit TransmissionDisable *Enable
Code 11 LengthPID:05h 02hSize:00h 02h (2 Bytes) 1^st Byte-01h~62h 2^nd Byte-62h~01hMinimum Length1~98 (Default: 4)Maximum Length98~1 (Default: 98)
Code 93 ReadabilityPID:06h 00hSize:00h 01h (1 Byte)-00h-01hDisableEnable *
Code 93 Check Digit TransmissionPID:06h 01hSize:00h 01h (1 Byte)-00h-01hDisable *Enable
Code 93 LengthPID:06h 02hSize:00h 02h (2 Bytes) 1^st Byte-01h~62h 2^nd Byte-62h~01hMinimum Length1~98 (Default: 1)Maximum Length98~1 (Default: 98)

Parameter(s)

< Table 8-1-3 > Reply Symbology Parameter(s) Field (Continued)

Parameter / PID / Size Options Descriptions
MSI/Plessey ReadabilityPID : 07h 00hSize : 00h 01h (1 Byte)- 00h- 01hDisable *Enable
MSI/Plessey SettingPID : 07h 01hSize : 00h 02h (2 Bytes) 1^st Byte- 00h- 01h- 02h 2^nd Byte- 00h- 01hCheck Digit SelectionMOD 10 check digit *MOD 10-10 check digitMOD 11-10 check digitCheck Digit TransmissionDisable *Enable
MSI/Plessey LengthPID : 07h 02hSize : 00h 02h (2 Bytes) 1^st Byte- 01h~62h 2^nd Byte- 62h~01hMinimum Length1~98 (Default: 4)Maximum Length98~1 (Default: 98)
Code 128/EAN-128 ReadabilityPID : 08h 00hSize : 00h 01h (1 Byte)- 00h- 01hDisableEnable *
Code 128/EAN-128 SettingPID : 08h 01hSize : 00h 01 (1 Byte)- 00h- 01hISBT Concatenation Off *ISBT Concatenation On
Code 128/EAN-128 LengthPID : 08h 02hSize : 00h 02h (2 Bytes) 1^st Byte- 01h~62h 2^nd Byte- 62h~01hMinimum Length1~98 (Default: 1)Maximum Length98~1 (Default: 98)
Code 128/EAN-128 Security LevelPID : 08h 03hSize : 00h 01h (1 Byte)- 00h- 01hLevel 0Level 1 *
GS1-128 ReadabilityPID : 08h 04hSize : 00h 01h (1 Byte)- 00h- 01hDisableEnable *
GS1-128 LengthPID : 08h 05hSize : 00h 02h (2 Bytes) 1^st Byte- 01h~62h 2^nd Byte- 62h~01hMinimum Length1~98 (Default: 1)Maximum Length98~1 (Default: 98)

Parameter(s)

< Table 8-1-3 > Reply Symbology Parameter(s) Field (Continued)

Parameter / PID / Size Options Descriptions
UK/Plessey ReadabilityPID: 09h 00hSize: 00h 01h (1 Byte)- 00h- 01hDisable *Enable
UK/Plessey SettingPID: 09h 01hSize: 00h 03h (3 Bytes) 1^st Byte- 00h- 01h 2^nd Byte- 00h- 01h 3^rd Byte- 00h- 01hPrimary Format SelectionStandard *CLSIConvert X to A-FDisable *EnableCheck Digit TransmissionDisable *Enable
UK/Plessey LengthPID: 09h 02hSize: 00h 02h (2 Bytes) 1^st Byte- 01h~62h 2^nd Byte- 62h~01hMinimum Length1~98 (Default: 4)Maximum Length98~1 (Default: 98)
Telepen ReadabilityPID: 0Ah 00hSize: 00h 01h (1 Byte)- 00h- 01hDisable *Enable
Telepen SettingPID: 0Ah 01hSize: 00h 02h (2 Bytes) 1^st Byte- 00h- 01h 2^nd Byte- 00h- 01hPrimary Format SelectionTelepen Full ASCII modeTelepen Numeric mode *Check Digit TransmissionDisable *Enable
Telepen LengthPID: 0Ah 02hSize: 00h 02h (2 Bytes) 1^st Byte- 01h~62h 2^nd Byte- 62h~01hMinimum Length1~98 (Default: 4)Maximum Length98~1 (Default: 98)
GS 1 DataBar ReadabilityPID: 20h 00hSize: 00h 03h (3 Bytes) 1^st Byte- 00h- 01h 2^nd Byte- 00h- 01h 3^rd Byte- 00h- 01hGS1 DataBar (RSS-14)DisableEnable *GS1 DataBar LimitedDisableEnable *GS1 DataBar ExpandedDisableEnable *
GS 1 DataBar Expanded LengthPID: 20h 01hSize: 00h 02h (2 Bytes) 1^st Byte- 01h~4Ah 2^nd Byte- 4Ah~01hMinimum Length1~74 (Default: 4)Maximum Length74~1 (Default: 74)

Parameter(s)

< Table 8-1-3 > Reply Symbology Parameter(s) Field (Continued)

Parameter / PID / Size Options Descriptions
Composite Code ReadabilityPID : 21h 00hSize : 00h 01h (1 Byte)- 00h- 01hDisable *Enable
UPC Composite ModePID : 21h 01hSize : 00h 01h (1 Byte)- 00h- 01hDisable *Enable
PDF417/ Micro PDF417ReadabilityPID : 22h 00hSize : 00h 02h (2 Bytes) 1^st Byte- 00h- 01h 2^nd Byte- 00h- 01hPDF417 ReadabilityDisableEnable *Micro PDF417 ReadabilityDisable *Enable
Codablock F ReadabilityPID : 23h 00hSize : 00h 01h (1 Byte)- 00h- 01hDisable *Enable
Code 16K ReadabilityPID : 24h 00hSize : 00h 01h (1 Byte)- 00h- 01hDisable *Enable
Code 16K LengthPID : 24h 01hSize : 00h 02h (2 Bytes) 1^st Byte- 01h~A0h 2^nd Byte- A0h~01hMinimum Length1~160 (Default: 1)Maximum Length160~1 (Default: 160)
Code 49 ReadabilityPID : 25h 00hSize : 00h 01h (1 Byte)- 00h- 01hDisable *Enable
Code 49 LengthPID : 25h 01hSize : 00h 02h (2 Bytes) 1^st Byte- 01h~51h 2^nd Byte- 51h~01hMinimum Length1~81 (Default: 1)Maximum Length81~1 (Default: 81)

Parameter(s)

< Table 8-1-3 > Reply Symbology Parameter(s) Field (Continued)

Parameter / PID / Size Options Descriptions
QR Code ReadabilityPID : 30h 00hSize : 00h 01h (1 Byte)- 00h- 01hDisableEnable *
Micro QR Code ReadabilityPID : 30h 01hSize : 00h 01h (1 Byte)- 00h- 01hDisableEnable *
QR Code SettingPID : 30h 02hSize : 00h 02h (2 Bytes) 1^st Byte- 00h- 01h 2^nd Byte- 00h- 01h- 02hQR Code AppendDisableEnable *QR Code Inverse ReadingDisable *EnableAuto Detect
QR Code LengthPID : 30h 03hSize : 00h 04h (4 Bytes) 1^st & 2^nd Byte- 01h~1BB1h 3^rd & 4^th Byte- 1BB1h~01hMinimum Length(Big Endian)1~7089 (Default: 1)Maximum Length(Big Endian)7089~1 (Default: 7089)
Data Matrix ReadabilityPID : 31h 00hSize : 00h 01h (1 Byte)- 00h- 01hDisableEnable *
Data Matrix SettingPID : 31h 01hSize : 00h 02h (2 Bytes) 1^st Byte- 00h- 01h 2^nd Byte- 00h- 01h- 02hData Matrix AppendDisableEnable *Data Matrix Inverse ReadingDisable *EnableAuto Detect
Data Matrix LengthPID : 31h 02hSize : 00h 04h (4 Bytes) 1^st & 2^nd Byte- 01h~C2Ch 3^rd & 4^th Byte- C2Ch~01hMinimum Length(Big Endian)1~3116 (Default: 1)Maximum Length(Big Endian)3116~1 (Default: 3116)
MaxiCode ReadabilityPID : 32h 00hSize : 00h 01h (1 Byte)- 00h- 01hDisable *Enable
MaxiCode LengthPID : 32h 01hSize : 00h 02h (2 Bytes) 1^st Byte- 01h~96h 2^nd Byte- 96h~01hMinimum Length1~150 (Default: 1)Maximum Length150~1 (Default: 150)

Parameter(s)

< Table 8-1-3 > Reply Symbology Parameter(s) Field (Continued)

Parameter / PID / Size Options Descriptions
Aztec ReadabilityPID : 33h 00hSize : 00h 01h (1 Byte)- 00h- 01hDisable *Enable
Aztec SettingPID : 33h 01hSize : 00h 02h (2 Bytes) 1^st Byte- 00h- 01h 2^nd Byte- 00h- 01h- 02hAztec AppendDisable *EnableAztec Inverse ReadingDisable *EnableAuto Detect
Aztec LengthPID : 33h 02hSize : 00h 04h (4 Bytes) 1^st & 2^nd Byte- 01h~EF8h 3^rd & 4^th Byte- EF8h~01hMinimum Length(Big Endian)1~3832 (Default: 1)Maximum Length(Big Endian)3832 ~1 (Default: 3832)
Chinese Sensible ReadabilityPID : 34h 00hSize : 00h 01h (1 Byte)- 00h- 01hDisable *Enable
Chinese Sensible LengthPID : 34h 01hSize : 00h 04h (4 Bytes) 1^st & 2^nd Byte- 01h~1E99h 3^rd & 4^th Byte- 1E99h~01hMinimum Length(Big Endian)1~7833 (Default: 1)Maximum Length(Big Endian)7833~1 (Default: 7833)
Korea Post CodePID : 50h 00hSize : 00h 01h (1 Byte)- 00h- 01hDisable *Enable
Australian Post ReadabilityPID : 51h 00hSize : 00h 01h (1 Byte)- 00h- 01hDisable *Enable
Australian Post Output FormatPID : 51h 01hSize : 00h 03h (3 Bytes)- 00h FFh FFh- 00h 00h 00h- 00h 7Fh FFh- 01h 00h FFhRaw format Output *Numeric Encoding OutputAlphanumeric Encoding OutputAutodiscriminate Output
US Planet ReadabilityPID : 52h 00hSize : 00h 01h (1 Byte)- 00h- 01hDisable *Enable
US Planet Check DigitTransmissionPID : 52h 01hSize : 00h 01h (1 Byte)- 00h- 01hDisable *Enable

Parameter(s)

< Table 8-1-3 > Reply Symbology Parameter(s) Field (Continued)

Parameter / PID / Size Options Descriptions
US Postnet ReadabilityPID : 53h 00hSize : 00h 01h (1 Byte)- 00h- 01hDisable *Enable
US Postnet Check Digit TransmissionPID : 53h 01hSize : 00h 01h (1 Byte)- 00h- 01hDisable *Enable
British Post ReadabilityPID : 54h 00hSize : 00h 01h (1 Byte)- 00h- 01hDisable *Enable
British Post Check Digit TransmissionPID : 54h 01hSize : 00h 01h (1 Byte)- 00h- 01hDisable *Enable
Japan Post ReadabilityPID : 55h 00hSize : 00h 01h (1 Byte)- 00h- 01hDisable *Enable
Netherlands KIX Code ReadabilityPID : 56h 00hSize : 00h 01h (1 Byte)- 00h- 01hDisable *Enable
Intelligent Mail ReadabilityPID : 57h 00hSize : 00h 01h (1 Byte)- 00h- 01hDisable *Enable

2.9 Device Info

Get Device Info (ALL)

Descriptions

Request the desired device information as well as DataWizard Premium information parameters

Packet Format

PrefixOpcodeStatusLengthParameter(s)LRCSuffix
7EhD6h00h 01h00hVariableSee Below Variable7Eh
1 Byte3Bytes1 Byte2 BytesVariable1 Byte1 Byte
Parameter(s)
First Parameter......Last Parameter
PID SizePID Size
2 Bytes2 Bytes......2 Bytes2 Bytes
See Next Page

. Host Requirements

If the device successfully received the above command issued by the host, the device will pack all requested parameters into a "Reply Device Info" message string then send to the host. Please refer to the "Reply Device Info" command for details. Otherwise, a "Device NAK" will be sent to host to indicate issue a command error. However, if the host can receive any response from the device within the user preset time-out duration, please resend the above command.

. Parameter(s) Field

Get Device Status can request multiple parameters at one time, so it takes compound parameters.

. Length

Total size (bytes) of the Parameter(s) field

.LRC

"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"

. Size

Total size (bytes) of the Options field

Parameter(s)

< Table 9-1-1 > Get Device Info Parameter(s) Field

Parameter PID Size
Custom ID 00h 00h00h 00h
Module No. 00h 01h00h 00h
Hardware ID 00h 02h00h 00h
Software ID 00h 03h00h 00h
DataWizard Premium Info. 01h 00h00h 00h
Total Count of Data Scripts 01h 01h00h 00h

Reply Device Info (ALL)

Descriptions

Reply the desired device information as well as DataWizard Premium information parameters. Reply Device Status is sent by the device in response to the Get Device Info command. It sends the values for all the desired parameters requested in the Get Device Info command.

Packet Format

PrefixOpcodeStatusLengthParameter(s)LRCSuffix
7Eh17h00h 01h00hVariableSee Below Variable7Eh
1 Byte3Bytes1 Byte2 BytesVariable1 Byte1 Byte

. Host Requirements

Since Reply Device Info is a device-to-host message, there is no response for this message.

. Parameter(s) Field

Reply Device Info can change multiple parameters at one time, so it takes compound parameters.

. Length

Total size (bytes) of the Parameter(s) field

.LRC

"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"

. Size

Total size (bytes) of the Options field

Parameter(s)

< Table 9-1-2 > Reply Device Info Parameter(s) Field

Parameter / PID / Size Options Descriptions
Custom IDPID : 00h 00hSize : 00h XXh (Variable Bytes)- XXh...XXh XXh(For example: CINO)
Module No.PID : 00h 01hSize : 00h XXh (Variable Bytes)- XXh...XXh XXh(For example: FUZZYSCAN F790WD)
Hardware IDPID : 00h 02hSize : 00h XXh (Variable Bytes)- XXh...XXh XXh(For example: OPIH3001M2400FR)
Software IDPID : 00h 03hSize : 00h XXh (Variable Bytes)- XXh...XXh XXh(For example: 1.03.01)
DataWizard Premium Info.PID : 01h 00hSize : 00h 0Fh- XXh...XXh XXh(For example: 0.9-1.0-0.90.01)
Total Count of Data ScriptsPID : 01h 01hSize : 00h 01h- 00h- 01h- 02h- 03h- 04h- 05h- 06h- 07h- 08h- 09h- 0Ah- 0Bh- 0Ch- 0Dh- 0Eh- 0Fh- 10h012345678910111213141516

Get Record Count (WF)

Descriptions

Request the total record count of Batch Mode

Available for F & L series

Packet Format

PrefixOpcodeStatusLengthParameter(s)LRCSuffix
7EhD6h 00h 03h00h 00h 00h<Null>D5h7Eh
1 Byte3Bytes1 Byte2 Bytes0 Byte1 Byte1 Byte

. Host Requirements

If the device successfully received the above command issued by the host, the device will pack all requested parameters into a "Reply Record Count" message string then send to the host. Please refer to the "Reply Record Count" command for details. Otherwise, a "Device NAK" will be sent to host to indicate issue a command error. However, if the host can receive any response from the device within the user preset time-out duration, please resend the above command.

. Parameter(s) Field

Get Device Status can request multiple parameters at one time, so it takes compound parameters.

. Length

Total size (bytes) of the Parameter(s) field

.LRC

"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"

. Size

Total size (bytes) of the Options field

Reply Record Count (WF)

Descriptions

Reply the total record count of Batch Mode

Available for F & L series

Packet Format

PrefixOpcodeStatusLengthParameter(s)LRCSuffix
7Eh17h00h 03h00h 00h 02hSee NotesVariable7Eh
1 Byte3Bytes1 Byte2 Bytes2 Bytes1 Byte1 Byte

. Host Requirements

Since Reply Device Info is a device-to-host message, there is no response for this message.

. Parameter(s) Field

Reply Device Info can change multiple parameters at one time, so it takes compound parameters.

. Length

Total size (bytes) of the Parameter(s) field

.LRC

"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"

. Size

Total size (bytes) of the Options field

.Notes

The two bytes record count is formatted as High Byte Low Byte. For example, number 60000 is described as EAh 60h.

2.10 Acknowledgement

Device ACK (ALL)

Descriptions

Device acknowledgement

Device ACK message is used to guarantee the reliability of packet transfers for commands that have no natural response, such as Action Commands, Set commands. Device ACK can not be disabled.

Packet Format

PrefixOpcode StatusLengthParameter(s)LRC Suffix
7Eh0Fh 00h 00h00h 00h 00h<Null> 0F7Eh
1 Byte3 Bytes 1 Byte2 Bytes0 Byte 1 Byte1 Byte

. Host Requirements

Since Device ACK is a device-to-host message, there is no response for this message.

. Parameter(s) Field

Device ACK message takes no parameters, so the Parameter(s) field is null.

. Length

Total size (bytes) of the Parameter(s) field

.LRC

"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"

Device NAK (ALL)

Descriptions

Device non-acknowledgement

Device NAK message is used to guarantee the reliability of packet transfers for commands that have no natural response, such as Action Commands, Set commands. On receiving a bad command, the scanner will send a Device NAK message to issue a command error including Opcode error, LRC check digit error and so on. Device NAK may not be disabled.

Packet Format

PrefixOpcode StatusLengthParameter(s)LRC Suffix
7Eh0Eh 00h XXh00h 00h 00h<Null> 0E7Eh
1 Byte3 Bytes 1 Byte2 Bytes0 Byte1 Byte1 Byte

. Host Requirements

On receiving a bad command, it takes the device about 1 second to clear out the command buffer. So you are NOT supposed to send other commands during this period of time after receiving the Device NAK message. Since Device NAK is a device-to-host message, there is no response for this message.

. Opcode Field

The third byte of the Opcode varies according to the error code. It is reserved.

. Parameter(s) Field

Device NAK message takes no parameters, so the Parameter(s) field is null.

. Length

Total size (bytes) of the Parameter(s) field

.LRC

"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"

Host ACK (ALL)

Descriptions

Host acknowledgement in packet format.

Host ACK message is sent from host to device to guarantee the correctness of the decode data.

Packet Format

PrefixOpcode StatusLengthParameter(s)LRC Suffix
7Eh91h 10h 00h00h 00h 04hSee below Variable7Eh
1 Byte 3Bytes 1 Byte 2 Bytes4 Bytes 1 Byte 1 Byte

. Host Requirements

There is no response for this message.

. Length

Total size (bytes) of the Parameter(s) field

.LRC

"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"

Parameter(s)

< Table 10-1 > Host ACK Parameter(s) Field

Parameter / PID / SizeOptionsDescriptions
Host ACKPID :Size : 00h 04h (4 Bytes)-XXh XXh...XXhIndicates the Data Packet ID (See Decode Data in Chapter 2.2) to which the Host ACK is replied

Host NAK (ALL)

Descriptions

Host non-acknowledgement

Host NAK message is sent from host to device to indicate that the data received is not correct.

Packet Format

PrefixOpcode StatusLengthParameter(s)LRC Suffix
7Eh90h 10h 00h00h 00h 04hSee below Variable7Eh
1 Byte 3Bytes 1 Byte 2 Bytes4 Bytes 1 Byte 1 Byte

. Host Requirements

There is no response for this message.

. Length

Total size (bytes) of the Parameter(s) field

.LRC

"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"

Parameter(s)

< Table 10-2 > Host NAK Parameter(s) Field

Parameter / PID / Size OptionsDescriptions
Host NAKPID :Size : 00h 04h (4 Bytes)-XXh XXh...XXhIndicates the Data Packet ID (See Decode Data in Chapter 2.2) to which the Host NAK is replied

Host ACK Extension (WF)

Descriptions

Host acknowledgement

Host ACK Extension is an extension of Host ACK which added a user defined message.

Available for F & L series

Packet Format

PrefixOpcodeStatusLengthParameter(s)LRCSuffix
7Eh91h10h 01h00h 02h00hSee Next PageVariable7Eh
1 Byte3Bytes1 Byte2 Bytes512 Bytes1 Byte1 Byte

. Host Requirements

There is no response for this message.

. Length

Total size (bytes) of the Parameter(s) field

.LRC

"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"

Parameter(s)

SizeParameter Value
4 BytesData Packet IDXXh XXh XXh XXh(See Notes)
2 BytesCode PageXXh XXh (See Notes)
1 ByteBit 7Manual Close-0 Disable-1 Enable
Bit 0~6Auto Close-0h Disable-3h after 3 seconds-5h after 5 seconds-8h after 8 seconds-Ah after 10 seconds
1 ByteBit 7~6Left AlignSet Bit 7 to 1, Bit 6 to 0
Right AlignSet Bit 7 to 0, Bit 6 to 1
Center AlignSet both Bit 7 and Bit 6 to 1 or 0
Bit 5~0Message Type-0h Tips-1h Warning-2h Question-3h Information-4h Error-5h Lock
1 ByteBit 4~7Beeping Type-0h Short-1h Long
Bit 0~3Number of Beep-0h Disable-1h Once-2h 2 times-3h 3 times-5h 5 times-8h 8 times-Ah 10 times
1 ByteBit 4~7Vibration Duration-1h 100ms-2h 200ms-3h 300ms-4h 400ms-5h 500ms
Bit 0~3Number of Vibration-0h Disable-1h 1 time-2h 2 times-3h 3 times-4h 4 times-5h 5 times
3 BytesMessage LengthXXh XXh XXh (See Notes)
499 BytesMessage ContentXXh... (See Notes)

.Notes

  1. Data Packet ID: If The Transmission Format is set to "Packet Data" (SETUP->Online Scanning -> Online Options -> Transmission Format -> Packet Data), the first 4 bytes of the Decode Data (Chapter 2.2) Command's Parameter field indicates the Data Packet ID.
  2. The following Chart lists all available Code Pages and their 2-byte Hex value.
437 OEM - United States B5h 01h
737 OEM - Greek (formerly 437G) E1h 02h
850 OEM - Multilingual Latin I 52h 03h
852 OEM - Latin II 54h 03h
855 OEM - Cyrillic 57h 03h
857 OEM - Turkish 59h 03h
860 OEM - Portuguese 5Ch 03h
863 OEM - French Canadian 5Fh 03h
865 OEM - Nordic 61h 03h
866 OEM - Russian62h 03h
932 ANSI/OEM Japanese (Shift-JIS)A4h 03h
936 ANSI/OEM - Simplified Chinese (GB2312)A8h 03h
950 ANSI/OEM - Traditional Chinese (Big5)B6h 03h
1250ANSI - Central EuropeanE2h 04h
1251ANSI - CyrillicE3h 04h
1252ANSI - Latin 1E4h 04h
1253ANSI - GreekE5h 04h
1254ANSI - TurkishE6h 04h
1255ANSI - HebrewE7h 04h
  1. Message Length has at most three bytes. If the first byte is 0xFF, the following two bytes represent the content length, formatted as High Byte Low Byte. Otherwise, the first byte represents the content length itself, and the following two bytes will become part of the message content.
  2. Message Content uses Little-endian UCS-2 character set. If shorter than 503 bytes, the rest bytes should be set to 00h.

Host NAK Extension (WF)

Descriptions

Host acknowledgement

Host NAK Extension is an extension of Host NAK which added a user defined message.

Available for F & L series

Packet Format

PrefixOpcodeStatusLengthParameter(s)LRCSuffix
7Eh90h10h 01h00h 02h 00hSee Next Page Variable7Eh
1 Byte3Bytes1 Byte2 Bytes512 Bytes1 Byte1 Byte

. Host Requirements

There is no response for this message.

. Length

Total size (bytes) of the Parameter(s) field

.LRC

"Opcode" XOR "Status" XOR "Length" XOR "Parameter(s)"

Parameter(s)

SizeParameter Value
4 BytesData Packet IDXXh XXh XXh XXh(See Notes)
2 BytesCode PageXXh XXh (See Notes)
1 ByteBit 7Manual Close-0 Disable-1 Enable
Bit 0~6Auto Close-0h Disable-3h after 3 seconds-5h after 5 seconds-8h after 8 seconds-Ah after 10 seconds
1 ByteBit 7~6Left AlignSet Bit 7 to 1, Bit 6 to 0
Right AlignSet Bit 7 to 0, Bit 6 to 1
Center AlignSet both Bit 7 and Bit 6 to 1 or 0
Bit 5~0Message Type-0h Tips-1h Warning-2h Question-3h Information-4h Error-5h Lock
1 ByteBit 4~7Beeping Type-0h Short-1h Long
Bit 0~3Number of Beep-0h Disable-1h Once-2h 2 times-3h 3 times-5h 5 times-8h 8 times-Ah 10 times
1 ByteBit 4~7Vibration Duration-1h 100ms-2h 200ms-3h 300ms-4h 400ms-5h 500ms
Bit 0~3Number of Vibration-0h Disable-1h 1 time-2h 2 times-3h 3 times-4h 4 times-5h 5 times
3 BytesMessage LengthXXh XXh XXh (See Notes)
499 BytesMessage ContentXXh... (See Notes)

.Notes

  1. Data Packet ID: If The Transmission Format is set to "Packet Data" (SETUP->Online Scanning -> Online Options -> Transmission Format -> Packet Data), the first 4 bytes of the Decode Data (Chapter 2.2) Command's Parameter field indicates the Data Packet ID.
  2. The following Chart lists all available Code Pages and their 2-byte Hex value.
437 OEM - United States B5h 01h
737 OEM - Greek (formerly 437G) E1h 02h
850 OEM - Multilingual Latin I 52h 03h
852 OEM - Latin II 54h 03h
855 OEM - Cyrillic 57h 03h
857 OEM - Turkish 59h 03h
860 OEM - Portuguese 5Ch 03h
863 OEM - French Canadian 5Fh 03h
865 OEM - Nordic 61h 03h
866 OEM - Russian62h03h
932 ANSI/OEM Japanese (Shift-JIS)A4h03h
936 ANSI/OEM - Simplified Chinese (GB2312)A8h03h
950 ANSI/OEM - Traditional Chinese (Big5)B6h03h
1250ANSI - Central EuropeanE2h 04h
1251ANSI - CyrillicE3h 04h
1252ANSI - Latin 1E4h 04h
1253ANSI - GreekE5h 04h
1254ANSI - TurkishE6h 04h
1255ANSI - HebrewE7h 04h
  1. Message Length has at most three bytes. If the first byte is 0xFF, the following two bytes represent the content length, formatted as High Byte Low Byte. Otherwise, the first byte represents the content length itself, and the following two bytes will become part of the message content.
  2. Message Content uses Little-endian UCS-2 character set. If shorter than 503 bytes, the rest bytes should be set to 00h.

Chapter 3 Customer Support

If you have any problem with your equipment, please contact Cino for technical support. Contact information is available at Cino website: www.cino.com.tw. If you purchased your product from a Cino business partner, please contact that business partner for support.

When you contact Cino for technical support, please provide following information:

  • Serial number of the unit
  • Model number
  • System Information

www.cino.com.tw

FuzzyScan Serial Command Manual

CINO GROUP

PC WORTH INT'L CO., LTD.

Table of contents Click a title to access it
Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : Cino

Model : F680

Category : Barcode Reader