24BCAC36 - Jokofu Avantco - Free user manual and instructions
Find the device manual for free 24BCAC36 Avantco in PDF.
| Product Type | Curved Dual Service Air Curtain Merchandiser |
| Brand | Avantco |
| Model | 24BCAC36 |
| Category | Jokofu (Refrigerator/Freezer Display Case) |
| Refrigerant Type | Flammable (R-290 likely) |
| Voltage / Frequency | 115V / 60Hz (typical, check nameplate) |
| Temperature Range (Refrigerator) | 33°F to 40°F (minimum set adjustable) |
| Defrost System | Automatic with manual override option |
| Temperature Control | Digital controller (Controller #1) |
| Top Section Configuration | Adjustable via perforated or solid baffles (ambient, refrigerated, or 50/50) |
| Condenser Coil Cleaning | Monthly cleaning recommended |
| Condensate Management | Evaporator pan with optional drain connection; wicking pads replace every 4-6 months |
| Electrical Requirements | Dedicated outlet, grounded, no extension cords |
| Safety Warnings | Flammable refrigerant; do not puncture tubing; service by trained personnel only |
| Compressor Protection | Wait 10 minutes before restarting after unplugging |
| Replacement Parts | Wicking pads (part #22477146), condenser coil cleaner |
| Installation Guidelines | Level surface, proper ventilation, ambient temperature < 75°F, humidity < 55% |
| Warranty | Not specified; malfunction due to improper conditions not covered |
Frequently Asked Questions - 24BCAC36 Avantco
User questions about 24BCAC36 Avantco
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
Download the instructions for your Jokofu in PDF format for free! Find your manual 24BCAC36 - Avantco and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. 24BCAC36 by Avantco.
USER MANUAL 24BCAC36 Avantco
natural_image
Exterior view of a modern glass-wrapped kitchen appliance (no visible text or symbols)
natural_image
Exterior view of a modern glass and black appliance with curved top (no visible text or symbols)Curved Dual Service

User Manual Curved Dual Service Air Curtain Merchandisers
Warnings
DANGER - RISK OF FIRE OR EXPLOSION, FLAMMABLE REFRIGERANT USED. TO BE REPAIRED ONLY BY TRAINED SERVICE PERSONNEL. DO NOT PUNCTURE REFRIGERANT TUBING.
PELIGRO — RIESGO DE INCENDIO O EXPLOSION. REFRIGERANTE INFLAMABLE UTILIZADO. PARA SER REPARADO SOLAMENTE POR PERSONAL DE SERVICIO CALIFICADO. NO PINCHAR LA TUBERÍA REFRIGERANTE.
DANGER — RISQUE DE FEU OU D'EXPLOSION. LE FRIGORIGÈNE EST INFLAMMABLE. CONFIER LES RÉPARATIONS À UN TECHNICIEN SPÉCIALISÉ. NE PAS PERFORER LA TUBULURE CONTENANT LE FRIGORIGENE.
CAUTION - RISK OF FIRE OR EXPLOSION. FLAMMABLE REFRIGERANT USED. CONSULT REPAIR MANUAL/OWNER'S GUIDE BEFORE ATTEMPTING TO SERVICE THIS PRODUCT. ALL SAFETY PRECAUTIONS MUST BE FOLLOWED.
This unit is intended for use in a temperature-controlled environment of less than 75^ F and 55% relative humidity. Malfunction due to improper conditions is not covered under warranty.
Before Installation
- If the shelf has a raised lip, the lip needs to be installed facing up towards the rear of the cabinet to promote proper air flow. Failure to install the shelves properly is considered user error and is not covered by warranty.
- If the unit has recently been transported on its side, please let unit stand upright for a minimum of 24 hours before plugging it in.
- Make sure that the unit has reached the desired temperature before loading the unit with products. This unit is meant for keeping cold products cold, not chilling warm products.
• Make sure that there is proper ventilation around the unit in the area where it will operate.
• Make sure all accessories are installed (i.e., shelves, shelf clips, casters) before plugging in the unit. - Do not attempt to remove or repair any component of the unit. Consult an authorized service technician for servicing/repair.
- Do not hang on doors or stand inside the unit.
- Please read through the manual in its entirety.
Cabinet Location Guidelines
• Install the unit on strong and leveled surfaces.
• If the surface is uneven, the unit may be noisy.
• The unit may malfunction if the surface is uneven.
I am a small object in an indoor space, and

User Manual Curved Dual Service Air Curtain Merchandisers
Electrical
- Ensure that the required voltage is being supplied at all times.
- The unit should be plugged into a grounded and properly-sized electrical outlet with appropriate over-current protection. Refer to the electrical requirements on the unit's nameplate.
• The unit should have its own dedicated outlet.
• DO NOT use extension cords. - Ensure the unit is not resting on or against the electrical cord.
• If the unit is not in use for a long period of time, unplug from the outlet.
• To avoid shock and fire hazards, DO NOT plug in or unplug the unit with wet hands. - After unplugging the unit, wait at least 10 minutes before plugging it back in. Failure to do so could cause damage to the compressor.
Temperature Controls
Adjusting the Temperature
- Your new refrigerator is already factory-set to run at optimum temperatures for food safety and should require no adjustments.
• Refrigerators are set to cycle between a minimum temperature of 33^ F and a maximum temperature of 40^ F. - Adjusting the temperature changes the minimum temperature at which your unit will run. Your unit will not run constantly at this setting. To change it, follow these instructions:
Digital Control Units
Controller #1

Operation
Defrost System
Automatic Defrost Cycle
• Refrigerator coils are kept below the freezing point (32°F).
- During compressor downtime, the evaporator fan continues to circulate air through the evaporator coil. This air circulation raises the coil temperature above the freezing point, melting any accumulated frost.
- Run-off water is drained into the evaporator pan and evaporated.
• Automatic defrost timers initiate at pre-set intervals and for a pre-determined duration.
- If a drainage pipe is available, lower the condensation drainage pipe and connect to a drain or condensate pump. Verify the pipe is unobstructed and it is lower than water receiver indicated by the line on the sticker.
- If no drain is available, the condensation drainage pipe can be hung up. The excess water will be evaporated with the condensate evaporator pan. Note that the use of this option will increase the energy consumption of the unit.
- If your cooler utilizes wicking pads for absorption of condensation, it is recommended that the pads (22477146) be replaced every 4-6 months depending on the ambient temperature and relative humidity of the environment.
- If water is leaking from the cabinet, check that the wicking pads have recently been changed and/or the drainage pipe is connected properly.
- WARNING: High humidity environments can cause increased amounts of condensation that can overflow the evaporator pan. Connecting the drainage pipe to a nearby drain is necessary for environments exceeding 55% relative humidity.
Running a Manual Defrost Cycle
- Units are pre-programmed to run automatic defrost cycles at preset intervals. However, if you would like to run a manual defrost cycle at any time, follow the steps below. Only models with digital controls can run a manual

User Manual
Curved Dual Service Air Curtain Merchandisers
Operation
Adjusting the Temperature of the Top Bakery Case Section
- Four perforated baffles come installed on the unit for the unit to operate with a fully refrigerated top section.
• Four solid baffles are included for altering the temperature of the top bakery case section. - The baffle will prevent (solid) or allow (perforated) refrigerated air from circulating through the display area and returning through the air return grille.
- The top bakery case section of the equipment can be ambient, refrigerated, or 50/50 ambient and refrigerated:
- For 100% ambient (non-refrigerated) conditions, two solid baffles must be positioned in each section of the cabinet to block the air flow and the air return grille.
- For 100% refrigerated conditions, two perforated baffles must be positioned in each section of the cabinet to allow air to circulate through the display area and return through the air return grille.
- For 50/50 ambient and refrigerated, position two solid baffles in the half of the case intended to be ambient to block airflow. For the half intended to be refrigerated, position two perforated baffles to allow
Perforated

natural_image
Pure geometric pattern of repeating rectangular blocks with no text or symbolsSolid

natural_image
Three horizontal rectangular bars with circular holes, no text or symbols present
Safety Information
Pay close attention to the safety notices in this section. Disregarding these notices may lead to serious injury and/or damage to the unit.
• To minimize shock and fire hazards, be sure to not overload outlet. This unit should be given its own outlet.
• DO NOT use extension cords.
• DO NOT put your hands under the unit while it is being moved.
- When the unit is not in use for a long period of time, unplug the unit from the outlet.
• After unplugging the unit, wait at least 10 minutes before plugging it back in. Failure to do so could cause damage to the compressor.
• To minimize shock and fire hazards, do not plug or unplug the cord with wet hands.
• Unplug the unit before performing maintenance or cleaning.
• To minimize shock and fire hazards, make sure that the unit is properly grounded.
• DO NOT attempt to remove or repair any component unless instructed by the factory.
• DO NOT allow the unit to rest on or against the electrical cord and/or plug.
• DO NOT hang on the doors.
• DO NOT store any flammable/explosive gas or liquids inside the unit.
• DO NOT attempt to alter or tamper with the electrical cord.
• DO NOT use the unit if the power cord is damaged.
Cleaning
DISCONNECT POWER CORD BEFORE CLEANING ANY PARTS OF THE UNIT.
It is strongly recommended that any servicing of the unit be performed by an authorized service technician.

User Manual Curved Dual Service Air Curtain Merchandisers
Cleaning
Cleaning the Condenser Coil
- A dusty condenser may lead to high energy consumption, less cooling effectiveness, and compressor damage.
- For efficient operation, keep the condenser surface free of dust, dirt, and lint.
• We recommend cleaning the condenser coil at least once per month.
• The condenser coil is located at the bottom behind the panel.
Cleaning the Condenser Coil Instructions
- Disconnect the electrical power from the unit.
- Remove the front cover and base cover with a screwdriver.
- Using a soft brush and/or vacuum, remove the dirt, lint, etc. from the finned condenser coil in a vertical direction.
- Clean the condenser with a commercial condenser coil cleaner, available from any kitchen equipment retailer. Ex. Noble Chemical Tech Line Coil Cleaners (148TLECCCLNR, 148TLHDCCLNR, 148TLECOILDD, 148TLFMCCLNR, 147TLEVPCLNR, or 147TLHDCCLNR).
- After cleaning, straighten any bent condenser fins with a fin comb.
- When finished, be sure to reinstall the front cover and base cover.
- Reconnect the electrical power to the unit.

Troubleshooting
| Problem | Possible Cause | Possible Solution |
| Compressor not running. | Fuse blown or circuit breaker tripped. Replace fuse or reset circuit breaker. | |
| Power cord unplugged. Plug in power cord. | ||
| Thermostat set too high. Set thermostat to lower temperature. | ||
| Cabinet in defrost cycle. Wait for defrost cycle to finish. | ||
| The unit is making noise under the bottom shelf. | Fan blade is broken. Replace fan blade. | |
| The unit is not cooling. | Unit is turned off. Turn unit on. | |
| Defrost cycle is running. End defrost cycle. | ||
| Refrigerant leaking. Contact a licensed service technician. | ||
| High cabinet temperature caused by weak air flow. | Evaporator coil is frosted over. Run a manual defrost cycle. (Page 5) | |
| Fan is damaged. Replace the fan. | ||
| The set point on the controller is too high. | Set the controller to a lower temperature. The set temperature is the lowest temperature the refrigerator will reach. | |
| Air flow is blocked by product. Rearrange or remove product to allow for complete air flow. | ||
| High cabinet temperature with normal | Refrigerant leaking. Contact a licensed service technician. | |
| The set point on the controller is too high. | Set the controller to a lower temperature. The set temperature is the lowest temperature the refrigerator will reach. | |
| Expansion valve failed. Contact a licensed service technician. | ||