V20BVCS3 - Jokofu Vintec - Free user manual and instructions
Find the device manual for free V20BVCS3 Vintec in PDF.
| Product Type | Built-in wine cellar (not fully integrated) |
| Brand | Vintec |
| Model | V20BVCS3 |
| Cabinet Height | 820 mm (with 40 mm adjustable feet) |
| Cabinet Width | 295 mm |
| Cabinet Depth (without handle) | 575 mm + 30 mm spacer = 605 mm |
| Cabinet Depth (with handle) | 575 mm + 43 mm handle + 30 mm spacer = 648 mm |
| Minimum Cutout Dimensions | 300 mm x 825 mm |
| Clearances Required | 2.5 mm sides, 5 mm top, 30 mm rear |
| Rear Ventilation Grille Size (min) | 200 mm x 40 mm |
| Front Ventilation | Yes, air expelled through grille under door; kick board vent min 150 cm² |
| Door Type | Glass door |
| Handle Included | Yes, front handle |
| Power Supply | 240 V / 10 A (standard Australian outlet) |
| Power Cord Length | 1.9 m, fixed on right side at back |
| Power Switch Location | On control panel |
| Surge Protection Recommended | Yes, to protect sensitive electronics |
| Ambient Temperature Range | 5°C to 35°C |
| Side-by-Side Installation | Allowed; maintain 5 mm gap between units |
| Outdoor Use | Limited; must be undercover, away from sunlight and heat, with increased clearances |
Frequently Asked Questions - V20BVCS3 Vintec
User questions about V20BVCS3 Vintec
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
Download the instructions for your Jokofu in PDF format for free! Find your manual V20BVCS3 - Vintec and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. V20BVCS3 by Vintec.
USER MANUAL V20BVCS3 Vintec
These units are not designed for outdoor use – please see conditions at the end of this information.
1. Cabinet dimensions:
Height 820mm (40mm adjustable feet) Width 295mm
Depth (without handle) 575mm + 30mm spacer = 605mm
Depth (with handle) 575mm + 43mm handle + 30mm spacer = 648mm
- This cabinet is not designed to be fully integrated behind a joinery door.

natural_image
Diagram showing two door-like structures with checkmark and cross symbols (no text or labels)- Please note that a minimum cut out of 300mm x 825mm is required to facilitate installation, removal, ventilation and servicing.

bar
| Value | |---| | 300.0 | | 825.0 |Minimum Cutout Diagram
- This cabinet requires 2.5mm clearance on both sides, 5mm at the top and 30mm clearance at the rear. A ventilation grid MUST be installed in the 30mm clearance at the rear. Because hot air rises it is imperative that a grille with a Minimum grid size of 200mm x 40mm is installed at the top of the back wall or on either side at the rear at the top giving cool fresh air full access to flow into the 30mm gap at the rear of the cabinet. This means that you must not install the grille close to other appliances such as an oven or to an area that is sealed or with out access to fresh cool air. (You MUST call the Vintec Service Department on 1800 771 776 if you do not understand any part of this statement. Failing to comply with the above specifications could result in WARRANTY void.)

- This cabinet is front venting. The cabinet draws air from the rear and expels through the grille under the door at the front. If a kick board is to be placed in front of the ventilation grill at the front a grill must be fitted in to the kick board with a minimum air flow allowance of 150cm2.

natural_image
Pure architectural floor plan lines without any text, numbers, or symbols- This cabinet has a power switch located on the control panel so powerpoint location is not critical.

natural_image
Simple line drawing of a device with a magnified inset showing a small component (no text or symbols)-
This cabinet requires a standard 240 volt/10 amp power point.
-
The power cord is 1.9m in length and is fixed on the right side at the back when looking from front of cabinet.

natural_image
Simple line drawing of a rectangular object with a curved line above it and a handle extending from its side (no text or symbols)- As with most appliances of today, this cabinet has sensitive electronic components which are susceptible to damage through lightning and electricity supply faults. It is therefore advised to use a power surge protector to avoid problems of this nature and to avoid piggybacking with other appliances.
Further Instructions:
The location you have selected for your wine cellar should:
- be unencumbered and well ventilated;
- be well away from any heat source and direct sunlight;
- not be too damp (laundry, pantry, bathroom etc.);
- have a flat floor,
- have a standard and reliable electricity supply (standard socket to country standards, linked to the ground), it is NOT recommended to use a multi-socket or extension lead.
- have a surge protector fitted to the electrical outlet away from the microwave.
Certain microwave ovens do not have wave interference shield. When placed within a 1 meter vicinity of the wine cabinet, they may affect the operation of the wine cabinet.
OUT DOOR USE
Please note that, whilst Vintec units are not designed for outdoor use they can be placed in certain Al Fresco areas but they MUST be well undercover – NEVER exposed to sunlight or the elements.
These units have glass doors & must not be situated where they are exposed to sunlight or reflected sunlight. In areas of high humidity there will be condensation on the glass doors. The units must be under significant cover & removed from any heat source (BBQ etc)
The ventilation requirement indicated for indoor use must be increased when situated outdoors by at least 2 cm on both sides & 3cm on top, 3 cm at the back with a large vent at the top of the back wall to facilitate heat evacuation. Because hot air rises it is imperative that a grille with a Minimum grid size of 200mm x 40mm is installed at the top of the back wall or on either side at the rear at the top giving cool fresh air full access to flow into the 30mm gap at the rear.

ONE OR MORE UNITS
The V20 Range can be installed next to each other in a row. All installation instructions should be followed.
The V20 range is equipped with a handle on the front of the unit. When installing a row of V20 units allow a minimum gap of 5mm between each unit and 2.5mm on the sides.

Notes:
- V20 model are built-in type as per the drawings thereafter;
The wine cellar should be placed where the ambient temperature is between 5^ C to 35^ C. If the ambient temperature is above or below this range, the performance of the unit may be affected. Placing your unit in extreme cold or hot conditions may cause interior temperatures to fluctuate. The ideal range of temperature may not be reached.
Not complying with any of the above instructions may result in WARRANTY void.
Vent Specifications
Suitable points for ventilation grille.
Note: Only one vent is required.


V20 Installation Dimensions


Front Elevation Top ViewSide View