USER MANUAL APWF-4050 APW Wyott

FRYERS OWNER'S MANUAL

Models: APWF-3540, APWF-4050, APWF-6575

APW Wyott APWF-4050 - Models: APWF-3540, APWF-4050, APWF-6575 - 1

FOR YOUR SAFETY: Do not store or use gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance.

APW Wyott APWF-4050 - Models: APWF-3540, APWF-4050, APWF-6575 - 2

APW Wyott APWF-4050 - Models: APWF-3540, APWF-4050, APWF-6575 - 3

WARNING: Improper installation, adjustment, alteration, service or maintenance can cause property damage, injury or death. Read the installation, operating and maintenance instructions thoroughly before installing or servicing this equipment.

APW Wyott APWF-4050 - Models: APWF-3540, APWF-4050, APWF-6575 - 4

Instruction to be followed in the event the user smells gas shall be posted in a prominent location. This information shall be obtained by consulting the local gas supplier.

APW Wyott APWF-4050 - Models: APWF-3540, APWF-4050, APWF-6575 - 5
Intertek

APW Wyott APWF-4050 - Models: APWF-3540, APWF-4050, APWF-6575 - 6
Intertek

PLEASE RETAIN THIS MANUAL FOR FUTURE REFERENCES.

This equipment is design engineered for commercial use only.

Phone : (214) 421-7366

Fax : (214) 565-0976

Toll Free: (800) 527-2100

Website: www.apwwyott.com

E-mail: info@apwwyott.com

P/N 300460 03/11

APW WYOTT

Foodservice Equipment Company

729 Third Avenue. Dallas. TX 75226

TABLE OF CONTENTS

Installation Instructions ....2

Operating Instructions....3

Maintenance Instructions....5

Warranty 8

IMPORTANT

Installing, Operating and Service Personnel:

  • Installation of the equipment should be performed by qualified, certified, licensed and/or authorized personnel who are familiar with and experienced in state/local installation codes.
  • Operation of the equipment should be performed by qualified or authorized personnel who have read this manual and are familiar with the functions of the equipment.
  • Service of the equipment should be performed by qualified personnel who are knowledgeable with APW Wyott equipment.

SHIPPING DAMAGE CLAIM PROCEDURE

The equipment is inspected & crated carefully by skilled personnel before leaving factory. The transportation company assumes full responsibility for safe delivery upon acceptance of this equipment. If shipment arrives damaged:

  1. Visible loss or damage: Note on freight bill or express delivery and have signed by the person making delivery.
  2. File claim for damages immediately: Regardless of the extent of damages.
  3. Concealed loss or damage: If damage is noticed after unpacking, notify the transportation company immediately and file 'Concealed Damage' claim with the transportation carrier. This should be done within fifteen (15) days from the date delivery and receipt of goods. Retain container for inspection.

INSTALLATION INSTRUCTIONS

The area around the appliance must be kept free and clear of combustibles such as solvents, cleaning liquid, broom, rags, etc.

Proper clearances must be provided at the front of the appliance for servicing and proper operation.

Provisions shall be incorporated in the design of the kitchen, to ensure adequate supply of fresh air and adequate clearance for air openings into the combustion chamber, for proper combustion, and ventilation.

For proper operation of the appliance, do not obstruct the flow of combustion and ventilation air.

The installation must conform with local codes, or in the absence of local codes, with the national fuel gas code, ANSI Z223.1 - 1988 (or latest addenda), National gas installation code, CAN/CGA - B 149.1, or the propane installation code, CAN/CGA - B 149.2 as applicable.

The appliance and its individual shut off valve must be disconnected from the gas supply piping system during any pressure testing of that system in excess of 12 PSI.

The appliance must be isolated from the gas supply piping system by closing its individual manual shut off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 12 PSI.

The gas supply line must be at least the same size as the gas inlet of the appliance.

CLEARANCES

Non-combustibleCombustible
Sides6"0"
Rear 6"0"
Floor 6"0"

Installation on non-combustible floor shall be with factory supplied legs or casters.

OPERATING INSTRUCTIONS

WARNING

APW Wyott APWF-4050 - WARNING - 1

Hot oil and hot surfaces can cause severe burns. Use caution when operating the fryer.

Do not attempt to move the fryer filled with hot oil or shortening.

Do not go near the area directly above the flue when fryer is in operation. Severe burns may be caused.

Drain hot oil in metal containers, do not use plastic buckets or glass containers.

APW Wyott APWF-4050 - WARNING - 2

LIGHTING INSTRUCTIONS

  1. Set the thermostat and the gas cock dial on the combination gas valve to the "OFF" position.
  2. Wait for five minutes.
  3. Turn gas cock dial on the combination gas valve to "Pilot" position.
  4. Depress the gas cock dial and apply a lighted match or taper to the pilot.
  5. Hold the gas cock dial depressed for about 30 seconds or until pilot stays lit before releasing.
  6. If the pilot does not stay lit, repeat step 4 and 5.
  1. After the pilot is lit, turn the gas cock dial to "ON" position.
  2. Turn the thermostat dial to any temperature setting and observe the burners ignition. It should ignite within four seconds.

APW Wyott APWF-4050 - LIGHTING INSTRUCTIONS - 1

CAUTION: Main burners shall not be "ON" when the vessel is empty. During testing, fill the vessel with liquid (oil or water) till above the heat transfer tubes.

APW Wyott APWF-4050 - LIGHTING INSTRUCTIONS - 2

FLEXIBLE COUPLINGS, CONNECTORS AND CASTERS

If the unit is to be installed with casters, the installation shall be made with a connector that complies with the Standard for Connectors for Movable Gas Appliances, ANSI Z21.69 or Connectors for Moveable Gas Appliances, CAN/CGA-6.16, and a quick-disconnect device that complies with the Standard for Quick-Disconnect Devices for Use With Gas Fuel, ANSI Z21.41, or Quick Disconnect Devices for Use with Gas Fuel CAN1-6.9. Locking front casters are provided to limit the movement of the appliance without depending on the connector or associated piping. A suitable strain relief must be installed with the flexible connector.

Restraining device may be attached to the back frame/panel of the unit.

All connections must be sealed with a joint compound suitable for LP gas and all connections must be tested with a soapy water solution before lighting pilots.

PREPARATION FOR USE

New units have a coating of oil on the interior of the vessel. Remove this coating with hot soapy water, washing soda, or any other grease dissolving liquid. Rinse thoroughly and drain until all residues are removed. Wipe dry.

Clean the baskets, crumb screen.

PILOT OPERATION

Check and make sure the pilot is lit. If not, refer to previous section for lighting the pilot.

BEFORE TURNING THE BURNERS ON

  1. Fill the vessel with liquid shortening or oil up to the "oil level" marking.
  2. Block of solid shortening should not be melted by setting it on top of tubes. This will damage the vessel and scorch fat. Either melt it first on another appliance or cut into small pieces and pack tightly below, between and above the burner tubes, without leaving any air spaces around the tubes. Turn the burners "ON" for about 10 seconds and turn "OFF" for about a minute. Repeat this "ON-OFF" cycle until all the shortening is melted. If scorching occurs, lower the "ON" time.
  3. Do not overfill the vessel.

After the vessel is filled with liquid shortening or oil, set the gas cock dial on the combination gas valve to the "ON" position.

Turn the thermostat to desired temperature setting.

DAILY SHUT-DOWN

At the end of the day, turn the gas cock dial on the combination gas valve and the thermostat to OFF position. Where applicable turn the power switch to OFF position. Filter the oil in all fryers.

MAINTENANCE INSTRUCTIONS

CLEANING

For continued performance efficiency and longevity of your Fryer it is essential to carry out a good maintenance program.

DAILY

  1. Remove and wash thoroughly all "loose" parts (basket hanger, baskets, crumb screen, etc.).
  2. Wipe clean all exterior and interior accessible surfaces and parts.
  3. Filter the liquid oil/shortening at the end of the day, replace if necessary. If fryer is under heavy use, filter more often during the day.

WEEKLY

  1. Shut down the fryer by turning off the gas cock dial and power supply, where applicable.
  2. Drain the fryer in a filter pan or steel container. Flush out sediments at the bottom of the vessel with liquid oil.
  3. Close the drain valve and fill the vessel with a mixture of boil-out solution and water.
  4. Relight the pilot and turn on the burners.
  5. When the solution starts to boil, turn off the thermostat and let the vessel soak to soften the deposit and/or carbon spots. (Approximately 1 hour).
  6. Drain off solution, scrub the insides with brush and rinse thoroughly.
  7. Repeat the cleaning procedure, if necessary.
  8. Wipe dry with soft towels and refill with clean oil/shortening.

APW Wyott APWF-4050 - WEEKLY - 1

WARNING: All water must be removed before adding oil or shortening. Not doing so can result in splattering of hot oil.

APW Wyott APWF-4050 - WEEKLY - 2

STAINLESS STEEL PARTS

Do not use steel wool, abrasive cloths, cleansers or powders to clean stainless steel surfaces. All stainless steel parts should be wiped regularly with hot soapy water during the day and a stainless steel liquid cleaner at the end of the day. To remove encrusted materials, soak in hot water to loosen the material, then use a wood or nylon scraper.

Contact the factory, factory representative or a local service company to perform maintenance and repairs.

APW WYOTT - FRYER 40/50 LBS

APW Wyott APWF-4050 - APW WYOTT - FRYER 40/50 LBS - 1

text_image Exploded view diagram of a refrigerator assembly with numbered parts for identification

APWF - 40/50 APW WYOTT - FRYER 40/50 LBS

ItemPart #DescriptionItemPart #Description
2 300359 FRYER BASKET - LARGE 35300357300111FLUE FRONT FRYER 40/50FLUE REAR FRYER 40/50
3 300189 FRYER BASKET - SMALL 36 300439 UPPER FRONT PANEL, WELDMENT
4300922300923CRUMB SCREEN FINE MESHCRUMB SCREEN REGULAR37 300152 BASKET HANGER 40/50
5 300436 DIFFUSER WELDMENT PANEL N/S 300271 KIT, CONVERSION TO NAT TSF- 4050
6 300231 PILOT BURNER - NATURAL (FRYER) N/S 300223 KIT, CONVERSION TO LP TSF-4050
7300227300226ORIFICE BELL #26 NATORIFICE BELL #16 (LP)
8 300157 THERMOPILE 32" FRYER
9 300260 DRAIN EXTENSION PIPE
10300239 DRAIN VALVE 1 1/4
11300899FRONT PANEL
12300443DOOR HINGE TOP
13300446DOOR ASSY FRYER 40/50
148717700DOOR MAGNET
152065847NAMEPLATE APW WYOTT SMALL
16300228 HI - LIMIT SWITCH
17300150 DOOR HINGE BOTTOM
18300229KNOB THERMOST WITH DIAL (FRYER)
19300113BRACKET THERMOSTAT/ HI - LIMIT
20300232THERMOSTAT - FRYER
21311039 6" CONE LEGS
22340264340265CASTER (WITH BRAKE) - OPTIONALCASTER (WITH OUT BRAKE) -OPTIONAL
23300155 SIDE PANEL - L/H
24300259 MANIFOLD TSF 40/50 ASSY
25300532300552ORIFICE HOOD - # 32 (NAT)ORIFICE HOOD - # 52 (LP)
26300188300225VALVE, COMBO GAS NAT FRYERVALVE, COMBO GAS LP FRYER
27300191BURNER
28300156 SIDE PANEL - R/H
29300120VESSEL WELD ASSY (3 TUBE FRYERTANK)
30300114PROBE HOLDER THERMOSTAT/ HI-LIMIT
31300440VESSEL COVER W/ HANDLE -OPTIONAL
32300456 BACK PANEL BOTTOM
33300138 BACK PANEL TOP
34300445300444UPPER FLUE PLATEUPPER FLUE

APW WYOTT EQUIPMENT LIMITED WARRANTY

APW Wyott Food service Equipment Company warrants it's equipment against defects in materials and workmanship, subject to the following conditions:

This warranty applies to the original owner only and is not assignable.

Should any product fail to function in its intended manner under normal use within the limits defined in this warranty, at the option of APW Wyott such product will be repaired or replaced by APW Wyott or its Authorized Service Agency. APW Wyott will only be responsible for charges incurred or service performed by its Authorized Service Agencies. The use of other than APW Wyott Authorized Service Agencies will void this warranty and APW Wyott will not be responsible for such work or any charges associated with same. The closest APW Wyott Authorized Service Agent must be used.

This warranty covers products shipped into the 48 contiguous United States, Hawaii, metropolitan areas of Alaska and Canada. There will be no labor coverage for equipment located on any island not connected by roadway to the mainland.

Warranty coverage on products used outside the 48 contiguous United States, Hawaii, and metropolitan areas of Alaska and Canada may vary. Contact the international APW Wyott distributor, dealer, or service agency for details.

Time Period

One year for parts and one year for labor, effective from the date of purchase by the original owner. The Authorized Service Agency may, at their option, require proof of purchase. Parts replaced under this warranty are warranted for the un-expired portion of the original product warranty only.

Exceptions

* Gas/Electric Cookline: Models HCB, HCRB, HMG, HTG, HHP, HHPS, GCB, GCRB, GF, GGM, GGT, CHP-H, EF, EG, EHP. Three (3) Year Warranty on all component parts, except switches and thermostats. (2 additional years on parts only. No labor on second or third year.)
* Broiler Briquettes, Rock Grates, Cooking Grates, Burner Shields, Fireboxes: 90 Day Material Only. No Labor.
* Heat Strips: Models FD, FDL, FDD, FDDL. Two (2)Year Warranty on element only. No labor second year.
* Glass Windows, Doors, Seals, Rubber Seals, Light Bulbs: 90 Day Material Only. No Labor.

In all cases, parts covered by extended warranty will be shipped FOB the factory after the first year.

Portable Carry In Products

Equipment weighing over 70 pounds or permanently installed will be serviced on-site as per the terms of this warranty. Equipment weighing 70 pounds or under, and which is not permanently installed, i.e. with cord and plug, is considered portable and is subject to the following warranty handling limitations. If portable equipment fails to operate in its intended manner on the first day of connection, or use, at APW Wyatt's option or its Authorized Service Agency, it will be serviced on site or replaced.

From day two through the conclusion of this warranty period, portable units must be taken to or sent prepaid to the APW Wyott Authorized Service Agency for in-warranty repairs. No mileage or travel charges are allowed on portable units after the first day of use. If the customer wants on-site service, they may receive same by paying the travel and mileage charges. Exceptions to this rule: (1) countertop warmers and cookers, which are covered under the Enhanced Warranty Program, and (2) toasters or roller grills which have in store service.

Exclusions

The following conditions are not covered by warranty:

* Equipment failure relating to improper installation, improper utility connection or supply and problems due to ventilation.
* Equipment that has not been properly maintained, calibration of controls, adjustments, damage from improper cleaning and water damage to controls.
* Equipment that has not been used in an appropriate manner, or has been subject to misuse or misapplication, neglect, abuse, accident, alteration, negligence, damage during transit, delivery or installation, fire, flood, riot or act of god.
* Equipment that has the model number or serial number removed or altered.

If the equipment has been changed, altered, modified or repaired by other than an Authorized Service Agency during or after the warranty period, then the manufacturer shall not be liable for any damages to any person or to any property, which may result from the use of the equipment thereafter.

This warranty does not cover services performed at overtime or premium labor rates. Should service be required at times which normally involve overtime or premium labor rates, the owner shall be charged for the difference between normal service rates and such premium rates. APW Wyatt does not assume any liability for extended delays in replacing or repairing any items beyond its control.

In all cases, the use of other than APW Wyott Authorized OEM Replacement Parts will void this warranty.

This equipment is intended for commercial use only. Warranty is void if equipment is installed in other than commercial application.

Water Quality Requirements

Water supply intended for a unit that has in excess of 3.0 grains of hardness per gallon (GPG) must be treated or softened before being used. Water containing over 3.0 GPG will decrease the efficiency and reduce the operation life of the unit.

Note: Product failure caused by liming or sediment buildup is not covered under warranty.

"THE FOREGOING WARRANTY IS IN LIEU OF ANY AND ALL OTHER WARRANTIES EXPRESSED OR IMPLIED INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR PARTICULAR PURPOSES AND CONSTITUTES THE ENTIRE LIABILITY OF APW WYOTT. IN NO EVENT DOES THE LIMITED WARRANTY EXTEND BEYOND THE TERMS STATED HEREIN."

APW wyott®

Phone : (214) 421-7366

Fax : (214) 565-0976

Toll Free: (800) 527-2100

Website: www.apwwyott.com

E-mail: info@apwwyott.com

APW WYOTT

Foodservice Equipment Company

729 Third Avenue. Dallas. TX 75226

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : APW Wyott

Model : APWF-4050

Category : Convection Oven