Product Type Centre plate with memory function and sensor connection
Model LS5232MS
Brand JUNG
Operating Modes Memory mode, push-button mode
Sun Protection Function Yes, with optional sun sensor (Art. No. 32 SD)
Travel Time Memory One Up and one Down travelling time can be saved
Signal Tone Buzzer for signalling operating mode changes
Brightness Threshold 20,000 lx
Ambient Temperature 0 ... +45 °C
Storage/Transport Temperature -10 ... +60 °C
Switch-over Time for Direction Change Approx. 1 s
Moving Time Approx. 120 s
Data According to EN 60730-1 Action 1.B, degree of soiling 2, measured surge voltage 4000 V, SELV limit value DC 12 V
Accessories Included None (sun sensor and extension flex sold separately)
Warranty As provided by law; send device with defect description to central customer service
Installation By electrically skilled persons only; disconnect power before work
Mounting Attach cover with frame onto Venetian blind control

Frequently Asked Questions - LS5232MS JUNG

How do I change the operating mode between memory and push-button?
Press the top or bottom of the cover for 8 to 12 seconds. After a series of tones, the mode switches. Four short tones indicate memory mode, while a 1-second continuous tone indicates push-button mode.
How do I save a travelling time?
In either mode, press the top of the cover for 3.5 to 8 seconds to save the Up time, or the bottom to save the Down time. A long continuous tone confirms the save.
How do I delete all saved travelling times?
Press the top or bottom of the cover for more than 12 seconds. After about 12 seconds, a 3-second continuous tone indicates deletion. The device resets to memory mode.
How does the sun protection function work?
With a compatible sun sensor connected, if brightness exceeds 20,000 lx for more than 2 minutes, the blind moves down until the sensor is shaded. It returns up after brightness drops below threshold for 15 minutes.
Can I use the sun protection function without a sensor?
No, the sun protection function requires a sun sensor (Art. No. 32 SD) to be connected to the terminal block.
What happens after a mains power failure?
If the failure lasts less than 30 minutes, saved travelling times are delayed by the duration. If longer than 30 minutes, both times are deleted and memory mode remains active.
How do I adjust the slat position?
Press the top or bottom of the cover for less than 1 second. The slats adjust in the desired direction as long as the button is pressed.
Is the device suitable for disconnecting from the supply voltage?
No, the device is not suitable for disconnection. Always use the circuit breakers to disconnect power before working on the device or load.
What accessories are available for this model?
Accessories include the Sunlight/dawn sensor (Art. No. 32 SD) and the Extension flex (Art. No. 32 K).
How should I clean the cover?
Clean the cover with a dry, soft cloth. Do not use abrasive cleaners or solvents.

User questions about LS5232MS JUNG

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Blind Management in PDF format for free! Find your manual LS5232MS - JUNG and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. LS5232MS by JUNG.

USER MANUAL LS5232MS JUNG

Centre plate with memory function and sensor connection Art. No.: ..5232 MS..

Operating instructions

1 Safety instructions

Electrical equipment may only be installed and fitted by electrically skilled persons. Serious injuries, fire or property damage possible. Please read and follow manual fully. Danger of electric shock. Always disconnect before carrying out work on the devise or load. At the same time, take into account all circuit breakers that supply dangerous voltage to the device or load.

Danger of electric shock. Device is not suitable for disconnection from supply voltage. These instructions are an integral part of the product, and must remain with the end customer.

2 Device components

(1) (2) (3)

Figure 1: Device components

(1) Venetian blind control
(2) Frame
(3) Cover

3 Function

Intended use

  • Operation of electrically-driven blinds and shutters
  • Operation on control of the Venetian blind control system

Product characteristics

  • One Up and Down travelling time can be saved respectively for daily execution
  • Buzzer for signalling
  • Evaluation of a sun sensor
  • Brightness threshold 20,000 lx

Operating modes

Memory mode:

- The saved Up and Down travelling times are executed in a 24-hour cycle.

- A signal tone sounds when the button is pressed.

i No signal tone sounds when activating via an extension.

Push-button mode:

- The saved travelling times are not executed.

- No signal tone sounds when the button is pressed.

Sun protection function

The connection of a sun sensor enables automatic shading when it is very bright outside. If the measured brightness exceeds the brightness threshold for more than 2 minutes, the blind moves downwards and stops as soon as the sun sensor is shaded.

The sun protection function is only activated if the Venetian blind has been moved to the upper end position and the control has deactivated automatically after 2 minutes. Each manual operation deactivates the sun protection.

If the brightness threshold is fallen short of for more than 15 minutes, the Venetian blind moves back to the upper end position.

Behaviour after a mains voltage failure

- A mains voltage failure that lasts less than 30 minutes causes the saved travelling times to be delayed by the duration of the power failure.

- After a mains voltage failure lasting longer than 30 minutes, both saved travelling times are deleted. After mains voltage return, the memory mode is active.

4 Operation

Moving the Venetian blind

■ Press top or bottom of cover for one to 3.5 seconds.

The Venetian blind moves in the desired direction to the end position or stops when the button is pressed again.

Adjusting the slats

■ Press top or bottom of cover for shorter than one second.

The slat position changes in the desired direction for as long as the button is pressed.

Changing operating mode

■ Press top or bottom of cover for 8 to 12 seconds.

After 2 seconds, several short signal tones are sounded and a long continuous tone of 1.5 seconds.

After a further 3 seconds, the operating mode switches over and the new operating mode is signalled:

4 short signal tones = memory mode

1-second continuous tone = push-button mode

Saving travelling times

The travelling times can be saved in push-button mode or memory mode. Only the current time can ever be saved as travelling time

- Press top of cover for 3.5 to 8 seconds to save the Up travelling time or press bottom of cover to save the Down travelling time.

After 2 seconds, several short signal tones are sounded and a long continuous tone of 1.5 seconds.

Once the continuous tone begins, the travelling time is saved. Any existing value will be overwritten.

i It is also possible to only save an Up or Down travelling time.

Deleting all travelling times

■ Press top or bottom of cover for longer than 12 seconds.

After 2 seconds, several short signal tones are sounded and a long continuous tone of 1.5 seconds.

Then the operating mode is signalled.

After about 12 seconds, a 3-second long continuous tone begins.

Once the continuous tone begins, the travelling times are deleted and the cover is in memory mode.

5 Information for electrically skilled persons

5.1 Fitting and electrical connection

Mounting and connecting

JUNG LS5232MS - Mounting and connecting - 1

DANGER!

Electrical shock when live parts are touched.

Electrical shocks can be fatal.

Before carrying out work on the device or load, disengage all the corresponding circuit breakers. Cover up live parts in the working environment.

The Venetian blind control is mounted and connected properly (see instructions for the relevant Venetian blind control).

■ If necessary, install sun sensor and connect to terminal block (see instructions for the sensors and control).
Connect the sun sensor with the correct polarity. If a sensor is connected with reversed polarity, this will result in malfunctions. It might not be possible to operate the cover any more.
■ Mount cover (3) with frame (2) onto the Venetian blind control (1) (figure 1).

6 Appendix

6.1 Technical data

Ambient temperature 0 ... +45 °C

Storage/transport temperature -10 ... +60 °C

Switch-over time for direction change approx. 1 s

Moving time approx. 120 s

Data according to EN 60730-1

Action 1.B

Degree of soiling 2

Meas. surge vol. 4000 V

SELV limit value DC 12 V

6.2 Accessories

Sunlight / dawn sensor Art. No. 32 SD

Extension flex Art. No. 32 K

6.3 Warranty

We reserve the right to make technical and formal changes to the product in the interest of technical progress.

We provide a warranty as provided for by law.

Please send the device with a description of the defect to our central customer service office.

ALBRECHT JUNG GMBH & CO. KG

Volmestraße 1

58579 Schalksmühle

Telefon: +49.23 55.8 06-0

Telefax: +49.23 55.8 06-2 04

kundencenter@jung.de

www.jung.de

Service Center

Kupferstr. 17-19

44532 Lünen

Germany

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : JUNG

Model : LS5232MS

Category : Blind Management