Product TypeDigital Kitchen Scale
DisplayLCD
Battery Type1x3V CR2032 (included) or 2x1.5V AA/AAA (not included)
Weight Unitsg / lb:oz (convertible)
Volume Unitsml / fl'oz (for water and milk)
Max Weight Capacity2000g or 5000g (depending on variant)
Resolution1g (typical)
Sensor TypeHigh precision strain gauge
FunctionsTare, Zero, Auto-off, Overload indication, Low battery indication
Auto-off Time2 minutes of inactivity
Platform MaterialPlastic (typical)
CleaningWipe with damp cloth; do not immerse
Safety FeaturesOverload protection, low battery warning
Accessories IncludedCR2032 battery, isolation sheet
Dimensions (approx.)Not specified in manual
Weight (approx.)Not specified in manual

Frequently Asked Questions - CEKT5B CONTINENTAL EDISON

How do I install the battery in the CEKT5B scale?
Open the battery case cover at the bottom. For CR2032, insert one side under the baffle and press down the other side. For AA/AAA, observe polarity and insert one side first then press down.
How do I switch between weight and volume modes?
Press the MODE button to cycle through Weight, Milk Volume, and Water Volume modes.
How do I convert between metric and imperial units?
Press the unit conversion button at the bottom of the scale to switch between g/ml and lb:oz/fl'oz.
What is the tare function and how do I use it?
Press the ZERO button to reset the display to zero. For loads ≤4% of max capacity, it acts as Zero; for larger loads, it acts as Tare and reduces the max capacity.
How do I turn off the scale manually?
When display shows '0', press ON/OFF once. When showing a weight, press and hold ON/OFF for 3 seconds.
What does the overload warning mean?
The display shows an overload indicator if the weight exceeds the max capacity. Remove the item to avoid damage.
How do I clean the scale?
Use a slightly damp cloth. Do not immerse in water or use chemical/abrasive cleaners. Clean plastic parts immediately after contact with spices, vinegar, or acidic foods.
How long does it take for the scale to auto-off?
The scale will auto-off after 2 minutes if the display shows '0' or the same weight reading.
Can I measure the volume of liquids other than water and milk?
The scale only provides volume modes for water and milk. For other liquids, use the weight mode.
What should I do if the scale displays a low battery indicator?
Replace the battery with a new one. The indicator shows when the battery is low.

User questions about CEKT5B CONTINENTAL EDISON

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Kitchen appliance in PDF format for free! Find your manual CEKT5B - CONTINENTAL EDISON and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. CEKT5B by CONTINENTAL EDISON.

USER MANUAL CEKT5B CONTINENTAL EDISON

natural_image Digital kitchen digital counter with LCD display and control buttons (no visible text or symbols)

CEKT5B

Balance Culinaire Kitchen Scale

natural_image Simple line drawing of a U-shaped component (no text or symbols)
  1. Indicate volume of water and milk
  2. Two weight unit systems g。「lb:oz convertible
  3. Two volume unit systems ml。「fl'oz convertible
  4. Low battery power/Overload indication
  5. With high precision strain gauge sensor
  6. With tare function
  7. Auto off

CONTINENTAL EDISON CEKT5B - 1

TO INSTALL OR REPLACE BATTERY

The battery type of scale depends on the product structure. Find the battery type of your scale according to the following pictures, then install and replace battery as described.

  1. 1x3V CR2032 lithium batteries (included). Remove isolation sheet before use;
  2. 2x1.5V (AA/AAA) batteries (excluded). Remove package foil before use;

CONTINENTAL EDISON CEKT5B - TO INSTALL OR REPLACE BATTERY - 1
PIC 1

Open the battery case cover at the bottom of scale:

A. Take out the used battery with the aid of a sharp object, as shown in picture.
B. Install new battery by putting one side of the battery beneath the battery baffle and then pressing down the other side.

AA/AAA AA/AAA

PIC 2

A. Take out used batteries, with the aid of a sharp object if needed.
B. Install new batteries by putting one side of the battery down first and pressing down the other side. (Please observe the polarity)

LCD

Tare Weight Negative Value

Zero Weight Weight mode

Milk volume mode

T=18:00.0 g ml floz lboz Weight unit(g) Volume unit(ml) Volume unit(fl'oz) Weight unit(lb'oz) Water volume mode Weight Milk Water

■ WORKING MODES
CONTINENTAL EDISON CEKT5B - TO INSTALL OR REPLACE BATTERY - 4
Weight mode

CONTINENTAL EDISON CEKT5B - TO INSTALL OR REPLACE BATTERY - 5
Milk volume mode

CONTINENTAL EDISON CEKT5B - TO INSTALL OR REPLACE BATTERY - 6
Water volume mode

■ UNIT CONVERSION BUTTON
CONTINENTAL EDISON CEKT5B - TO INSTALL OR REPLACE BATTERY - 7

natural_image Simple line drawing of a U-shaped component with two vertical leads (no text or symbols)

At the bottom of scale, you can find a unit conversion button as shown in picture.

■ TO CONVERT WEIGHT UNIT

If the scale is with both unit systems of Metric (g, ml) or Imperial (lb:oz, fl'oz), press MODE button to choose working mode (weight, milk volume, water volume), then press unit conversion button to convert between two systems. Take the conversion of weight unit for example:

Weight mode 0° Weight Milk Water 0° Weight Milk Water 0° Weight 250 0.00 400 400 400

* When setting g as weight unit, the default volume unit is ml;
* When setting lb:oz as weight unit, the default volume unit is fl'oz.

Remark: The unit system of scale depends on sales destination or the requirement of distributor.

■ TO START WEIGHING
CONTINENTAL EDISON CEKT5B - ■ TO CONVERT WEIGHT UNIT - 2

  1. Weighing mode
    A. Place the scale on a solid and flat surface.
    B. Place bowl (if used) on the scale before turning on the scale.
    C. Press "ON/OFF" to enter weighing mode.
    D. Wait until LCD shows all information.
    E. Load weighing object on to start weighing,LCD will show the weight reading.
    F. If the weighing object is water or milk, press MODE button to choose volume mode and view the volume of weighing object.

CONTINENTAL EDISON CEKT5B - ■ TO CONVERT WEIGHT UNIT - 3

flowchart
graph TD
    A["Weight"] --> B["0 ml"]
    C["Milk"] --> D["87 ml"]
    E["Water"] --> F["587 ml"]
    G["Water"] --> H["605°"]
  1. Volume indication mode
    A. Place the scale on a solid and flat surface.
    B. Press "ON/OFF" to turn on the scale.
    C. Wait until LCD shows "0", and press MODE button to choose "Water" or "Milk" mode.
    D. Put a liquid container onto the scale platform.
    E. Press ZERO button to reset LCD to "0".
    F. Pour liquid (water or milk) into the container, LCD shows the volume of the liquid.
    G. Press MODE button to choose "Weight" mode and view the weight of liquid.

■ "ZERO" OR "TARE" FUNCTION

To weigh different loads consecutively without removing loads from the scale. Put first Load on the scale, get weight reading. Press ZERO button to reset the LCD reading to "0" before adding next load. You can repeat this operation.

ZERO Weight Milk Water Weight Milk Water 0g

■ Condition 1: "ZERO" function

When total sum of all loads on scale ≤4% of scale's max.weight capacity. (4%=80g when capacity is 2000g; 200g when capacity is 5000g)

LCD will show “----” or “0g” each time ZERO is perssed. “----” means not stable, please wait for a moment. “0g” and meanwhile an icon “o” on lower left corner of LCD mean “ZERO” function is active. Max.weight capacity remains unchanged.

-535g Weight Milk Water T - 0g Weight Milk Water T - 68g Weight Milk Water -603g Weight Milk Water T - 0g Weight Milk Water

■ Condition 2: "TARE" function

When total sum of all loads on scale >4% of scale's max.weight capacity. (4%=80g when capacity is 2000g; 200g when capacity is 5000g)

LCD will show “----” or "0g" each time ZERO is pressed. “----” means not stable, please wait for a moment. "0g" and meanwhile an icon "TARE" on upper left corner of LCD mean "TARE" function is active. Max. Weight capacity is reduced by total weight of all loads.

■ Under this condition:

By pressing ZERO, you can see the total weight of all loads on the scale. If you want to weigh more loads, just press ZERO to reset LCD reading to '0' again.

■ AUTO SHUT OFF

9° 2 mins

Auto shut-off occurs if display shows '0' or shows the same weight reading for 2 minutes.

■ MANUAL SHUT OFF

ON/OFF

To maximize battery life, always press ON/OFF again to turn off the scale after using.

Note: when display shows "0", press "ON/OFF" to turn off the scale; when display shows weight reading, press "ON/OFF" for 3 seconds to turn off the scale.

■ WARNING INDICATORS

CONTINENTAL EDISON CEKT5B - ■ WARNING INDICATORS - 1

  1. Replace new battery.
  2. Scale overload. Remove item to avoid damage.Max.weight capacity is indicated on the scale.

⚠ CLEANING AND CARE

  1. Clean the scale with a slightly damp cloth. DO NOT immerse the scale in water or use chemical/abrasive cleaning agents.
  2. All plastic parts should be cleaned immediately after contact with fats, spices, vinegar and strongly flavored/colored foods. Avoid contact with acids citrus juices.
  3. Always use the scale on a hard, flat surface. DO NOT use on carpet.

CONTINENTAL EDISON CEKT5B - ⚠ CLEANING AND CARE - 1

This marking indicates that this product should not be disposed with other household wastes throughout the EU.

To prevent possible harm to the environment or human health from uncontrolled waste disposal, recycle it responsibly to promote the sustainable reuse of material resources.

To return your used device, please use the return and collection systems or contact the retailer where the product was purchased.

They can take this product for environmental safe recycling.

CONTINENTAL EDISON

120-126 Quai de Bacalan

CS11584

33000 Bordeaux

IMPORTE PAR :

A.M.C.

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : CONTINENTAL EDISON

Model : CEKT5B

Category : Kitchen appliance