Vent-A-Hood

JDH236C3SS - Range hood Vent-A-Hood - Free user manual and instructions

Find the device manual for free JDH236C3SS Vent-A-Hood in PDF.

📄 7 pages English EN Download 💬 AI Question 10 questions ⚙️ Specs
Notice Vent-A-Hood JDH236C3SS - page 1
Pick your language and provide your email: we'll send you a specifically translated version.
Product TypeWall Mount Range Hood
BrandVent-A-Hood
ModelJDH236C3SS
SeriesJDH/C3 Designer Series
Installation TypeWall Mount
VentingDucted to outdoors
Filtration TypeMagic Lung centrifugal filtration (no mesh or baffle filters)
Blower OptionsSingle (B100) or Dual (B200)
Duct Size (Single Blower)6" round (28 sq in)
Duct Size (Dual Blower)8" round (50 sq in)
Electrical Rating115V, 60Hz, up to 4.0A
Blower Motor Speed1550 RPM
Airflow (Single Blower)300 CFM (SP 0.0"), 450 Equivalent CFM
Airflow (Dual Blower)600 CFM (SP 0.0"), 900 Equivalent CFM
Sound Level (Sones)5.4 (single), 6.5 (dual)
Cleaning SystemE-Z Clean shield (removable)
Blower AccessRemovable blower housing via suitcase latches
Duct MaterialOnly smooth galvanized metal duct allowed
Safety FeaturesBack draft damper, grounding required
Installation RequirementsMust be installed by qualified installer; follow local codes
ComplianceASHRAE 62.2, NFPA, local codes

Frequently Asked Questions - JDH236C3SS Vent-A-Hood

What is the recommended installation height above the cooking surface?
The bottom edge of the hood should be no more than 30" above the cooking surface for optimum performance.
Can I use flexible duct for this range hood?
No, only smooth galvanized metal duct is allowed. Flexible or corrugated duct will restrict airflow and reduce performance.
What size duct do I need for a single or dual blower?
Single blower (B100) requires 6" round duct (28 sq in). Dual blower (B200) requires 8" round duct (50 sq in). Never reduce the duct size.
How do I clean the E-Z Clean shield?
The E-Z Clean shield is removable. Lightly pull it toward the front of the hood to remove. It can be washed with mild detergent and water. Ensure it is dry before reinstalling.
How do I access the blower motor for maintenance?
First, remove the E-Z Clean shield. Then unsnap the suitcase latches on each side of the blower housing. Pull the housing forward and gently tip it to clear the blower wheel. Then remove the three screws retaining the motor and unplug it.
What is the difference between CFM and Equivalent CFM?
Equivalent CFM is a measure of the Magic Lung blower efficiency compared to conventional baffle or mesh filters. For example, the dual blower delivers 600 CFM (SP 0.0") but achieves 900 Equivalent CFM due to centrifugal filtration.
Can I terminate the vent in an attic or chimney?
No, the duct must be vented to the outdoors. Do not terminate in an attic or chimney. Use a wall louver or roof jack with a gravity damper.
What electrical requirements are needed?
The hood requires 115V, 60Hz power. Each motor box needs a separate circuit. Use a 1/2" UL listed electrical clamp. The current draw is up to 4.0A for dual blower. Ensure proper grounding.
How many blower configurations are available?
The hood supports up to four configurations: single blower (B100), dual blower (B200), single+dual (B100+B200), or two duals (2xB200). Each requires different duct sizes and transitions.
What is the noise level in sones?
The sound level is 5.4 sones for single blower and 6.5 sones for dual blower at normal operation. Higher CFM settings may increase noise.

User questions about JDH236C3SS Vent-A-Hood

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Range hood in PDF format for free! Find your manual JDH236C3SS - Vent-A-Hood and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. JDH236C3SS by Vent-A-Hood.

USER MANUAL JDH236C3SS Vent-A-Hood

Read and Save These Instructions

All Hoods Must Be Installed By A Qualified Installer

INSTALLATION INSTRUCTIONS

JDH/C3 DESIGNER SERIES

WALL MOUNT HOOD

Read All Instructions Thoroughly Before Beginning Installation WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:

A. Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction. Switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally during installation.
B. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
C. Ducted fans must always be vented to the outdoors.
D. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent back drafting. Follow the heating equipment manufacturer's guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and local code authorities.
E. ASHRAE residential ventilation standard 62.2 limits exhaust fans (total) to a maximum of 15 CFM per 100 square feet of occupiable space, unless a back drafting test is performed or make-up air is provided. Consult a local HVAC engineer for make-up air evaluation.

WARNING - TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK

VentA Hood®

Ducting Do's and Don'ts

General Requirements

  • Observe local codes regarding special duct requirements and placement of duct against combustibles.
    • Using Vent-A-Hood transitions (back page) will ensure proper efficiency.
    • Using Vent-A-Hood roof jacks or wall louvers (back page) will ensure proper efficiency.
    • Where possible, seal joints with duct tape.
    • The hood must be ducted to the outdoors without restrictions.

Blower Requirements

- The single blower unit (B100) requires 6" round duct or equivalent (28 square inches), and the dual blower unit (B200) requires 8" round duct or equivalent (50 square inches).

Blower Combined Duct Dize Sq. Inch Area Vent-A-Hood Transition

Single (B100) 6" round or equivalent 28 sq. in. N/A
Dual (B200) 8" round or equivalent 50 sq. in. N/A
Single and Dual (B100 & B200) 10" round or equivalent 79 sq. in. VP562 (Included)
Two Duals (Two B200s)12" round or equivalent113 sq. in.VP563 (Included)

Ducting Requirements

• NEVER reduce the duct size.
- When combining ducts together, the square inch area must reflect the total square inch area of the ducts being combined.
- Do not use flexible or corrugated duct. This type of duct will restrict airflow and reduce performance.
• Only use smooth, galvanized, metal duct.
• Make the duct run as short and as straight as possible with as few turns as possible.
- Avoid sharp-angled turns. Instead, use smooth, gradual turns such as adjustable elbows or 45 degree angled turns.
- For duct runs over 20 feet, increase the duct diameter by one inch for every ten feet of duct.
• A 90 degree elbow is equal to 5 feet of duct.

Termination Requirements

• Airflow must not be restricted at the end of the duct run.
• A wall louver or roof jack is required for each duct run.
• Every wall louver or roof jack must include a gravity damper to prevent back drafts.
- Do not use screen wire or spring-loaded doors on wall louvers or roof jacks.
- Do not terminate venting into an attic or chimney.

Vent-A-Hood JDH236C3SS - Termination Requirements - 1

VentA Hood® Installation Details

1) Read all instructions thoroughly before beginning installation.
2) When installing a JDH/C3 wall mount range hood, it is recommended that the bottom edge of the hood be located no more than 30" above the cooking surface for optimum performance.

Vent-A-Hood JDH236C3SS - VentA Hood® Installation Details - 1

natural_image Line drawing of a 3D isometric coat hood (no text or symbols)

30" 36" JDH/C3

3) IF THE HOOD IS TO BE "BACK VENTED", PROCEED DIRECTLY TO STEP 4.

Install the duct from the outside of the home down to the location of the exhaust outlet on the top of the hood allowing room for the transition (if applicable). If a transition is used, install duct down to the location of the transition outlet plus 1". This will allow the transition to engage 1" inside of duct. Consult the connection diagrams (on next page) for further details on exhaust outlet placement.

Use duct tape to seal all joints. A complete listing of available Vent-A-Hood ducting materials is provided on the back page of this instruction sheet.

Transition heights are as follows:

Single Blower (B100): 6" round duct will connect directly to the top of the hood.

Dual Blower (B200): 8" round duct will connect directly to the top of the hood.

Single and Dual Blower (B100 & B200): 10" round combination transition (VP562, included) is 17 1/2 tall.

Two Dual Blowers (Two B200s): 12" round combination transition (VP563, included) is 16 1/2" tall.

4) Remove the hood from its packaging and place the back of the hood on the floor or countertop in front of the wall where it will hang.

VentA Hood®

Installation Details Continued

Connection Diagram (36" - 48" Widths)
Vent-A-Hood JDH236C3SS - Installation Details Continued - 1

Connection Diagram (36" - 48" Widths)
Wall Side 1 ¾" Electrical 5 ¼"5 ½" Vent Holes 8" Outlet Centerline of Hood

600 CFM B200 Dual Blower
(Top View)

Vent-A-Hood JDH236C3SS - Installation Details Continued - 3

natural_image Technical line drawing of a conical-shaped component with internal features and a 9-inch height dimension (no text or symbols)

(Front View)

Connection Diagram (48"-60" Widths)
900 CFM B200 Dual & B100 Single Blower (Top View) 12 3/8" 9-4" 1 5/8" 10" Outlet Centered On Hood Top Wall Side Electrical (2) Centerline Of Hood

Vent-A-Hood JDH236C3SS - Installation Details Continued - 5

natural_image Technical line drawing of a mechanical component with internal features and dimension label (9")

VP562 Standard Transition Installed (Front View)

Duct Cover (Top of Hood) 10° Dia. or 12° Dia. Transition Location "Centered"

The transition shown (VP562)
is installed in the hood at the
factory as a standard item.
It will be located in the exact center of the duct cover (left to right & front to rear).

Connection Diagram (54"-66" Widths)
16½" 5½" 1¾" Wall Side 1¾" 7" Electrical (2) 12° Outlet Centered On Top Of Hood Centerline Of Hood

1200 CFM Double B200 Dual Blowers
(Top View)

Vent-A-Hood JDH236C3SS - Installation Details Continued - 8

natural_image Technical diagram of a mechanical component with internal channels and mounting holes (no text or symbols)

VP563 Standard Transition
Installed (Front View)

Duct Cover (Top of Hood) 10° Dia. or 12° Dia. Transition Location "Centered"

The transition shown (VP563)
is installed in the hood at the factory as a standard item. It
will be located in the exact
center of the duct cover (left to
right & front to rear).

VentA Hood®

Installation Details Continued

5) Remove the shipping tape that is securing the E-Z Clean shield(s) inside the hood. Remove the E-Z Clean shield(s) by lightly pulling it toward the front of the hood. Gently close the back draft damper(s) from the top side of the hood. To remove the blower housing(s), unsnap the suitcase latches (one on each side of the housing). The housing(s) should be pulled forward and gently "tipped" to clear the blower wheel(s) and then out of the hood.

Vent-A-Hood JDH236C3SS - Installation Details Continued - 1

natural_image Technical line drawing of a mechanical component with a cylindrical shaft and flange (no text or symbols)

Vent-A-Hood JDH236C3SS - Installation Details Continued - 2

natural_image Simple line drawing of a rectangular box with a circular vent and mounting holes (no text or symbols)

Vent-A-Hood JDH236C3SS - Installation Details Continued - 3

Vent-A-Hood JDH236C3SS - Installation Details Continued - 4

natural_image Technical line drawing of a mechanical bracket or bracket (no text or symbols)

6) Remove the three screws retaining the blower motor(s). Unplug and remove the motor(s), taking care not to damage the blower wheel(s). It is not necessary to remove the blower wheel from the motor.

Vent-A-Hood JDH236C3SS - Installation Details Continued - 5

natural_image Technical line drawing of a cylindrical mechanical component with mounting holes and a cable (no text or symbols)

Warning: Make sure power is off and locked at the service disconnecting means on the service panel during installation.

7) Install an appropriate 1/2" UL listed electrical wire clamp through each motor box electrical opening on top of the hood. Install electrical wiring from the service panel to the hood location for each motor box. Consult the connection diagrams (on previous page) for further details on electrical placement. Extend wire(s) to the hood. Electrical connection(s) will occur before the hood is installed on the wall.

Model Volts AmpsHz RPMCFM SP@0.0"Equivalent CFM*CFM SP@0.1"CFM SP@0.2"CFM SP@0.3"Minimum Round Duct SizeSones#
B100 Single1152.56015503004502732452256" (28 in. ^2 )5.4
B200 Dual1154.06015506009005314804308" (50 in. ^2 )6.5
B200 Dual & B100 Single1156.0601550900135080472565510" (79 in. ^2 )6.3
Two B200 Duals1157.560155012001800106296086012" (113 in. ^2 )6.6

Because the Magic Lung® blower uses centrifugal filtration rather than conventional baffle or mesh filters, the Magic Lung® blower can handle cooking equipment with higher cubic feet per minute (CFM) requirements and can deliver equivalent CFM much more efficiently than other filtration systems. When comparing the Magic Lung® with other blower units made by other manufacturers, use the "Equivalent CFM". Ratings in accordance with the Standard Test Code by the Energy Systems Laboratory of the Texas Engineering Experiment Station.

8) If using a duct cover, remove the duct cover from its packaging and remove the mounting screws from the base of the duct cover. Place the duct cover on the top of the hood and secure it through the knockout openings using the mounting screws previously removed.

Lift the hood or the hood and duct cover assembly to the location on the wall where it will be installed. Lightly mark the wall with a short, horizontal mark along the bottom edge of the hood. When finished, remove the hood or hood and duct cover assembly from the wall. If applicable, leave the duct cover installed on the hood.

9) Remove the hood from the wall. On the back side of the hood, measure the distance between the bottom edge of the hood and the top edge of the wood mounting strip. Measure this distance above the horizontal line made in Step 8 and lightly mark the wall with a level, horizontal line. Measure where the center (left to right) of the hood will be and mark the upper, horizontal line on the wall with a short, vertical centerline.
10) Remove the screws inside the top of the back of the hood that retain the wood strip that is recessed in the mounting channel. Note: Some retaining screws may be located behind the blower(s). Remove the wood mounting strip from the back of the hood and place the top edge of the strip on the upper, level horizontal line on the wall. Referencing the vertical centerline from Step 9, place the mounting strip on the wall so it is centered (left to right) in the space where the hood will be located. Drill pilot holes in the strip to prevent splitting. Using proper hardware, attach the mounting strip to at least two wall studs.

VentA Hood®

Installation Details Continued

11) FOR BACK VENTING APPLICATIONS ONLY. IF NOT BACK VENTING, PROCEED DIRECTLY TO STEP 12.

Note: Wall studs may interfere with back venting installations. Additional framing may be required. It is necessary to cut a duct access hole in the wall prior to installing the hood.

To accomplish this, first remove and set aside any duct cover that was previously installed in Step 8. Hold the hood on the mounting strip by aligning the channel at the top of the back of the hood over the wood mounting strip on the wall. Place the appropriate elbow on top of the hood in line with the hood exhaust collar. On the wall, trace around the elbow. Remove the hood and elbow from the wall. Cut around the outside of the traced line, avoiding wall studs. Install the duct from the outside of the home to the opening in the wall. Use duct tape to seal joints. If applicable, place the duct cover back onto the top of the hood and reattach it to the hood.
12) Hang the hood on the mounting strip by aligning the channel at the top of the back of the hood over the wood mounting strip on the wall. While holding the hood in place, mark locations on the mounting strip through the two mounting holes in the channel at the top of the hood. Some mounting holes may be located behind the blower(s). Remove hood and drill 3/32" pilot holes at the center of marks in the wood strip to prevent splitting.
13) FOR BACK VENTING APPLICATIONS ONLY. IF NOT BACK VENTING, PROCEED DIRECTLY TO STEP 14.
Place the appropriate elbow on the top of the hood. The elbow should be placed with the non-crimped end on the inside the collar of the exhaust outlet. Use duct tape to seal joint. Insert the electrical wire(s) from the service panel into the electrical wire clamp on each motor box. Tighten the wire clamp(s). While securing the slack in the wire(s), lift the hood (and duct cover) up to the wall and hang the hood on the mounting strip, taking care to properly align the duct connection between the elbow on the hood and the duct in wall. Secure the hood to the mounting strip by installing the screws (previously removed in Step 10) into the pilot holes drilled in Step 12. SKIP STEPS 14 AND 15. PROCEED DIRECTLY TO STEP 16.
14) Insert the electrical wire from the service panel into the electrical wire clamp on each motor box. Tighten the wire clamp(s). Cut a piece of duct of sufficient length to meet the duct in the ceiling allowing room for the transition (if applicable). If a transition is used, cut the duct to reach the transition outlet plus 1". This will allow the transition to engage 1" inside of the duct. See Page 3 for transition heights. One end of the duct must be crimped to fit inside the duct in the ceiling. Insert the non-crimped end over the transition or into the exhaust collar on the top of the hood and seal with duct tape.
15) While securing the slack in the wire(s), lift the hood (and duct cover) up to the wall and hang the hood on the mounting strip, taking care to properly align the duct connection between the hood and the duct in the ceiling. Secure the hood to the mounting strip by installing the screws (previously removed in Step 10) into the pilot holes drilled in Step 12.
16) From inside the hood, using UL listed wire nuts, attach the "neutral" wire(s) to the white lead(s), the "hot" wire(s) to the black lead(s), and the ground wire(s) to the green lead(s) inside the motor box(es).

Warning: Do not operate hood without proper ground connection.

17) Plug the motor(s) into the hood and reinstall the blower motor(s) using the three retaining screws that were previously removed in Step 6.
18) Replace the blower housing(s) and the E-Z Clean shield(s). Make sure that the damper(s) open and close smoothly.
19) Refer to the Owner Maintenance Guide Operating Instructions for proper hood operation. Test all blower and light functions to ensure they are operating properly.

VENTINGACCESSENT AHAOD®

WALL LOUVERVent-A-Hood JDH236C3SS - VENTINGACCESSENT AHAOD® - 1 Vent-A-Hood JDH236C3SS - VENTINGACCESSENT AHAOD® - 2MODEL DIMVP526 6" RoundVP527 7" RoundVP528 8" RoundWALL LOUVERVent-A-Hood JDH236C3SS - VENTINGACCESSENT AHAOD® - 3 Vent-A-Hood JDH236C3SS - VENTINGACCESSENT AHAOD® - 4MODEL DIMVP554 10" RoundWALL LOUVERVent-A-Hood JDH236C3SS - VENTINGACCESSENT AHAOD® - 5 Vent-A-Hood JDH236C3SS - VENTINGACCESSENT AHAOD® - 6MODEL DIMVP555 12" RoundRECTANGULAR WALL LOUVERVent-A-Hood JDH236C3SS - VENTINGACCESSENT AHAOD® - 7 Vent-A-Hood JDH236C3SS - VENTINGACCESSENT AHAOD® - 8MODEL DIMVP538 6" x 8 1⁄2"VP560 3 1⁄4" x 10"
LOW PROFILE ROOF JACK(MAXIMUM 4/12 PITCH)Vent-A-Hood JDH236C3SS - VENTINGACCESSENT AHAOD® - 9MODEL DIMVP539 6" RoundVP540 7" RoundVP541 8" RoundLOW PROFILE ROOF JACK(MAXIMUM 4/12 PITCH)Vent-A-Hood JDH236C3SS - VENTINGACCESSENT AHAOD® - 10MODEL DIMVP552 10" RoundVP553 12" RoundLOW PROFILE ROOF JACK(MINIMUM 4/12 PITCH)Vent-A-Hood JDH236C3SS - VENTINGACCESSENT AHAOD® - 11MODEL DIMVP539-HP 6" RoundVP540-HP 7" RoundVP541-HP 8" RoundLOW PROFILE ROOF JACK(MINIMUM 4/12 PITCH)Vent-A-Hood JDH236C3SS - VENTINGACCESSENT AHAOD® - 12MODEL DIMVP552-HP 10" RoundVP553-HP 12" Round
ADJUSTABLE ELBOWVent-A-Hood JDH236C3SS - VENTINGACCESSENT AHAOD® - 13MODEL DIMVP513 6" RoundVP514 7" RoundVP515 8" RoundBACK/SIDE VENT ELBOWVent-A-Hood JDH236C3SS - VENTINGACCESSENT AHAOD® - 14MODEL DIMVP561 8" to 6" x 8 1⁄2"3 1⁄4" x 10" BACK VENT ELBOWVent-A-Hood JDH236C3SS - VENTINGACCESSENT AHAOD® - 15MODEL DIMVP559 3 1⁄4" x 10"3 1⁄4" x 10" TO 7" TRANSITIONVent-A-Hood JDH236C3SS - VENTINGACCESSENT AHAOD® - 16MODEL DIMVP521 3 1⁄4" x 10" to 7"
MULTI-BLOWER TRANSITIONVent-A-Hood JDH236C3SS - VENTINGACCESSENT AHAOD® - 17MODEL DIMVP562 6" & 8" to 10"VP563 8" & 8" to 12"M1200 STANDARD TRANSITIONVent-A-Hood JDH236C3SS - VENTINGACCESSENT AHAOD® - 18MODEL DIMVP566 21" x 8" to 10"STANDARD ISLAND TRANSITIONVent-A-Hood JDH236C3SS - VENTINGACCESSENT AHAOD® - 19MODEL DIMVP565 5" x 16" to 8"CLUSTER BLOWER TRANSITIONVent-A-Hood JDH236C3SS - VENTINGACCESSENT AHAOD® - 20MODEL DIMVP564 8" & 8" to 12"
OFFSET L & R TRANSITIONFOR ISI AND BI OWERSVent-A-Hood JDH236C3SS - VENTINGACCESSENT AHAOD® - 21MODEL DIMVP542 Top LeftVP543 Top RightSIDE VENT TRANSITION L & RFOR ISI AND BI OWERSVent-A-Hood JDH236C3SS - VENTINGACCESSENT AHAOD® - 22MODEL DIMVP544 Left SideVP545 Right SideOFFSET KIT - ROUNDVent-A-Hood JDH236C3SS - VENTINGACCESSENT AHAOD® - 23MODEL DIMVP529 6" Rnd to 7" RndOFFSET KIT - RECTANGULARVent-A-Hood JDH236C3SS - VENTINGACCESSENT AHAOD® - 24MODEL DIMVP550 6" Rnd to 3 1⁄4" x 10"
"Y" TRANSITIONVent-A-Hood JDH236C3SS - VENTINGACCESSENT AHAOD® - 25MODEL DIMVP517 8" & 8" to 12"VP518 6" & 8" to 12"VP551 6" & 8" to 10"ROUND DUCT PIPEVent-A-Hood JDH236C3SS - VENTINGACCESSENT AHAOD® - 26MODEL DIMVP500 6" RoundVP501 7" RoundVP502 8" Round3 1⁄4" RECTANGULAR DUCT PIPEVent-A-Hood JDH236C3SS - VENTINGACCESSENT AHAOD® - 27MODEL DIMVP504 3 1⁄4" x 10"VP505 3 1⁄4" x 12"VP506 3 1⁄4" x 16"6" RECTANGULAR DUCT PIPEVent-A-Hood JDH236C3SS - VENTINGACCESSENT AHAOD® - 28MODEL DIMVP507 6" x 8 1⁄2"