Graff

G-9111 - Bathroom accessory Graff - Free user manual and instructions

Find the device manual for free G-9111 Graff in PDF.

📄 4 pages English EN Download 💬 AI Question 10 questions ⚙️ Specs
Notice Graff G-9111 - page 1
Pick your language and provide your email: we'll send you a specifically translated version.
Product Type Towel Bar
Brand Graff
Model G-9111
Installation Type Wall-mounted with mounting plates and anchors
Primary Function Holding towels and bath linens
Included Components Towel bar, mounting plates, set screws, anchors (for wall mounting)
Required Tools 1/4" (6mm) carbide drill bit, electric drill, Phillips screwdriver, level
Drilling into Tile Use masking tape to prevent drill slip; use carbide drill bit
Adjustability Mounting plates have adjustment slots to tighten or loosen bar fit
Care Instructions Clean with damp cloth and mild soap only; blot dry with soft towel
Prohibited Cleaners No abrasive cleaners, acids, solvents, or harsh polishes
Finish Warranty Limited lifetime warranty for original purchaser against finish defects
Cartridge Warranty Lifetime warranty on ceramic cartridge (if applicable)
General Warranty Defects in materials and workmanship covered for ownership period
Warranty Exclusions Damage from abrasives, chemicals, misuse, improper installation, or alteration
Customer Service Call 1-800-954-GRAF (4723) for toll-free support
Manual Languages English, Spanish
Safety Warning Ensure secure mounting; drill into grout lines on tile when possible

Frequently Asked Questions - G-9111 Graff

How do I install the Graff G-9111 towel bar?
First, position the towel bar and mark the wall. Use a level to ensure alignment. Disassemble by loosening set screws. Locate mounting plates at the marks, drill 1/4" holes, insert anchors, and screw plates to the wall. Assemble parts back and tighten set screws to grip the mounting plate stems.
What tools are required for installation?
You will need a 1/4" (6mm) carbide drill bit, an electric drill, a Phillips screwdriver, and a level.
Can I mount the towel bar on ceramic tile?
Yes. Place masking tape on the tile before marking to prevent drill slip. Try to locate holes on a grout line. Use a carbide drill bit to drill through tile.
How should I clean the Graff G-9111?
Use a soft towel with soap and water only. Wipe gently and blot dry. Never use abrasive cleaners, acids, solvents, or harsh polishes.
What is the warranty coverage?
Graff provides a limited lifetime warranty on the finish for the original purchaser. The ceramic cartridge is warranted for life. Defects in materials and workmanship are covered for the ownership period.
What voids the warranty?
Damage from improper installation, neglect, accident, misuse, or use that violates instructions voids the warranty. Also, using abrasive cleaners or chemicals will void the finish warranty.
How do I adjust the towel bar if it is too loose?
Loosen the set screws, move the mounting plates inward on the adjustment slots, and retighten. This will tighten the bar between the posts.
Are replacement parts available?
Yes, Graff offers replacement parts. Contact customer service at 1-800-954-GRAF (4723) or visit www.graffcollection.com for assistance.
Can I use this towel bar in a commercial setting?
The warranty excludes commercial, industrial, or business use. For residential use only.
Does the towel bar come with installation instructions?
Yes, the product includes a user manual with step-by-step instructions in English and Spanish. You can also download the PDF from notice-facile.com.

User questions about G-9111 Graff

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Bathroom accessory in PDF format for free! Find your manual G-9111 - Graff and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. G-9111 by Graff.

USER MANUAL G-9111 Graff

Thank you for selecting our product. We are confident we can fully satisfy your expectations by offering you a wide range of technologically advanced products which directly result from our many years of experience in faucet and fitting production.

Estimado Cliente

ESPAÑOL

For care, use soft towel with soap and water only! Under no circumstances should use any chemicals.

ATENCIÓN

→ You should have the following tools:

1/4" (6mm) carbide drill bit,
electric drill,
- Phillips screwdriver,
level.

Insert towel bar into posts and position fixture in desired location on the wall.
→ Lightly mark outline of each cover plate on the wall.
→ Disassemble product by loosening the set screws.
Locate mounting plates in centers of marked circles. Mark location of the mounting screws. On ceramic tile, try to locate the mounting hole locations on a grout line. However, the center-to-center measurement of the posts must be maintained as marked. If mounting into ceramic tile, place masking tape on the mounting area before marking the location to prevent the drill bit from sliding across the tile. To drill through ceramic tile, obtain a 1/4" (6mm) diameter carbide drill bit.
Drill 1/4" (6mm) holes and push in anchors flush with the wall. Screw mounting plates to the wall.
Assemble balance of parts to mounting plates as shown. Lightly push fixture against the wall. Tighten set screws to grip mounting plate stems.
If bar in between posts is too loose, move mounting plates inward on the adjustment slots.

ESPAÑOL

ESPAÑOL

HOTLINE FOR HELP NUMERO DE EMERGENCJA

For toll-free information and answers to your questions, call: Llame sin costo para obteiner informacion y respestas a sus preguntas:

Graff G-9111 - HOTLINE FOR HELP NUMERO DE EMERGENCJA - 1

1 - 800 - 954 - GRAF (4723)

www.graffcollection.com

→ Position fixture in desired location on the wall.
→ Lightly mark outline of each cover plate on the wall.
→ Disassemble product by loosening the set screw.
Locate mounting plate in centers of marked circles. Mark location of the mounting screws. On ceramic tile, try to locate the mounting hole locations on a grout line. If mounting into ceramic tile, place masking tape on the mounting area before marking the location to prevent the drill bit from sliding across the tile. To drill through ceramic tile, obtain a 1/4" (6mm) diameter carbide drill bit.
Drill 1/4" (6mm) holes and push in anchors flush with the wall. Screw mounting plate to the wall.
Assemble balance of parts to mounting plate as shown. Lightly push fixture against the wall. Tighten set screw to grip mounting plate stem.

ESPAÑOL

Your Graff product is designed and engineered in accordance with the highest quality and performance standards. Be sure not to damage the finish during installation. Care should be given to the cleaning of this product. Although its finish is extremely durable, it can be damaged by harsh abrasives or polish. Never use abrasive cleaners, acids, solvents, etc. to clean any Graff product. To clean, simply wipe gently with a damp cloth and blot dry with a soft towel.

Graff products, Graff 3701 W. Burnham Street, Unit B Milwaukee, WI 53215 warrants to the purchaser that the materials and workmanship of the product will be free from defects for the term of ownership for the original purchaser.

The Graff ceramic cartridge, is warranted for the lifetime of the product. If at any time a valve mechanism should fail, Graff will provide a replacement part free of charge.

A limited lifetime warranty for the finish is provided to the original purchaser of the Graff unit.

This warranty does not apply to product that has been subject to abrasives, chemicals, scratches, dents, accidents, misuse, improper installation, alteration, or that has not received reasonable care. Purchaser should return any defective or non-conforming product to the factory, freight prepaid, at the above address.

This warranty is limited to replacement parts only and does not include or cover labor charges or damage incurred in installation, replacement or repair or any consequential or incidental damages whatsoever, nor does it cover or include damages for property, personal injury or economic loss.

Any damage to this Graff faucet as a result of improper installation, neglect, accident, misuse or any use that violates the original instructions provided by us, WILL VOID THE WARRANTY. This warranty is valid to the original consumer purchaser and excludes commercial, industrial or business use of this Graff faucet.

All dimensions and drawings are for reference only. For details, please refer to actual products.

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : Graff

Model : G-9111

Category : Bathroom accessory