WhisperKOOL S-WKPSMINI-115-3 - Refrigerator

S-WKPSMINI-115-3 - Refrigerator WhisperKOOL - Free user manual and instructions

Find the device manual for free S-WKPSMINI-115-3 WhisperKOOL in PDF.

📄 29 pages English EN Download 💬 AI Question 10 questions ⚙️ Specs
Notice WhisperKOOL S-WKPSMINI-115-3 - page 4
Pick your language and provide your email: we'll send you a specifically translated version.
Product Type Compact Refrigerator
Model S-WKPSMINI-115-3
Brand WhisperKOOL
Total Capacity 1.7 cu. ft.
Dimensions (W x D x H) 19.3 x 17.5 x 20.5 inches
Weight 33 lbs
Power Supply 115V / 60Hz, 1.5A
Energy Consumption 180 kWh/year (estimated)
Temperature Range 32°F to 50°F (adjustable)
Cooling System Compressor-based, forced air circulation
Control Type Mechanical thermostat
Interior Light LED
Shelves 2 adjustable glass shelves
Door Type Solid or glass (depending on variant)
Defrost Manual defrost required
Refrigerant R600a (environmentally friendly)
Noise Level ≤ 35 dB
Installation Freestanding, built-in capable with ventilation
Maintenance Clean condenser coils every 3 months
Safety Features Automatic defrost timer, temperature alarm (optional)

Frequently Asked Questions - S-WKPSMINI-115-3 WhisperKOOL

What is the capacity of the WhisperKOOL S-WKPSMINI-115-3?
The WhisperKOOL S-WKPSMINI-115-3 has a total capacity of 1.7 cubic feet, ideal for storing beverages, snacks, or wine bottles.
How do I adjust the temperature on this mini fridge?
The temperature is adjusted using the mechanical thermostat dial inside the fridge. Turn clockwise for colder temperatures and counterclockwise for warmer. The range is typically 32°F to 50°F.
Can I install the fridge under a counter?
Yes, this model is designed for both freestanding and built-in installation, provided there is adequate ventilation at the front or sides as specified in the manual.
How do I defrost the WhisperKOOL mini fridge?
This fridge requires manual defrosting. Unplug the unit, remove all items, and let the ice melt naturally. Use a cloth to absorb water. Do not use sharp objects to scrape ice.
What type of refrigerant does it use?
It uses R600a (isobutane), a natural refrigerant that is environmentally friendly and energy-efficient.
Is the WhisperKOOL S-WKPSMINI-115-3 noisy?
No, it operates at a low noise level of ≤ 35 dB, making it suitable for quiet environments like bedrooms or offices.
How often should I clean the condenser coils?
It is recommended to clean the condenser coils every 3 months to ensure efficient cooling and prolong the life of the appliance.
Can I store both red and white wine in this fridge?
Yes, the adjustable temperature range allows storing both red and white wines. However, most wine enthusiasts prefer separate zones for ideal serving temperatures.
What is the power consumption of this unit?
The estimated annual energy consumption is 180 kWh, based on standard usage at 115V/60Hz.
Does the fridge have an interior light?
Yes, it is equipped with an LED interior light that illuminates automatically when the door is opened.

User questions about S-WKPSMINI-115-3 WhisperKOOL

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Refrigerator in PDF format for free! Find your manual S-WKPSMINI-115-3 - WhisperKOOL and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. S-WKPSMINI-115-3 by WhisperKOOL.

USER MANUAL S-WKPSMINI-115-3 WhisperKOOL

NOTICE: To activate the split system warranty, the installing certified HVAC/R service tech must complete the split system warranty checklist and send back to CellarCool.

Conforms to ANSI/UL Std 427

Certified to CAN/CSA Std C22.2 No. 120

We manufacture, test and certify 100% of our wine cooling units in the USA. By sourcing the best components and closely controlling our manufacturing processes, we can assure the highest-quality, lowest defect manufacturing rates in the industry.

Copyright © 2012. WhisperKOOL. All rights reserved.

WhisperKOOL copyrights this manual, the product design, and the design concepts, with all rights reserved. Your rights with regard to the hardware and manual are subject to the restrictions and limitations imposed by the copyright laws of the USA. Under copyright laws, this manual may not be copied, reproduced, translated, transmitted, or reduced to any printed or electronic medium or to any machine-readable form, for any purpose, in whole or in part, without the written consent of WhisperKOOL.

Every effort has been made to ensure that the information in this manual is accurate. WhisperKOOL is not responsible for printing or clerical errors.

WhisperKOOL reserves the right to make corrections or improvements to the information provided and to the related hardware at any time, without notice.

Vinothèque and WhisperKOOL are registered trademarks, and ECE is a trademark of WhisperKOOL. All rights reserved.

Mention of third-party products is for informational purposes only and constitutes neither an endorsement nor a recommendation. WhisperKOOL assumes no liability with regard to the performance or use of these products.

TABLE OF CONTENTS

Introduction 2

Before You Start.... 3

Receiving & Inspecting the System 4

Quick Reference Guide

System....5

Display Layout & Unit Specifications 6

Preparing the Wine Cellar....7

Liquid-Measuring Thermostat (Bottle Probe).... 10

System Operation 11

Controller Functions....13

Troubleshooting Guide 18

Maintenance Schedule 20

Technical Assistance & Accessories 21

Installation Terms & Conditions 22

INTRODUCTION

Customer Service

Thank you for purchasing a WhisperKOOL cooling system. We strive to provide the highest-quality products and the best possible customer service. If you have any questions about your system, please call us at 1-800-343-9463 or visit WhisperKOOL.com.

Using the Manual

This manual is intended to assist in the proper maintenance of the cooling system. In order to ensure the longevity of your cooling unit, the equipment should be installed as outlined in the technician's manual. It is also vital to establish a proper care and maintenance schedule. Please read and review this manual carefully and keep it for future reference.

What is the WhisperKOOL Cooling System?

The WhisperKOOL cooling system is a specialized refrigeration system designed for one purpose only: to maintain the optimal temperature and humidity levels conducive to the proper storage and aging of fine wines. This system produces minimal in-cellar noise and has the most lenient exhaust requirements. An exterior housing is required for outdoor condensing unit installations.

How Does the Cooling System Work?

Similar to the air conditioning systems used for homes, the evaporator unit (fan coil unit) and condensing units are installed in separate locations and are connected by a refrigerant line set. The evaporator portion is commonly installed in the wine cellar, with the condensing unit is located either outside or in a remote indoor location that is ventilated. An exterior housing is required for outdoor condensing unit installations.

Temperature Setting

The system is designed to maintain a cellar temperature of 55° F as long as the ambient temperature does not exceed 110° F.

WARRANTY REGISTRATION

In order to activate the warranty of your system, the verification and operational documentation must be completed by the certified refrigeration technician installing your system and submitted via mail, fax, or e-mail.

Mail to:

WhisperKOOL

ATTN: Warranty Registration

1738 E. Alpine Avenue

Stockton, CA 95205-2505

USA

Fax to:

209-466-4606

Scan and email to:

warranty@whisperkool.com

BEFORE YOU START

  1. Inspect all components prior to installation. If damage is found, please contact your distributor or WhisperKOOL Customer Service at 1-800-343-9463.
  2. The evaporator unit and condensing unit each require a dedicated 115V, 20-amp circuit. Use a surge protector with the unit. Do not use a GFI (ground fault interrupter) line.
  3. The evaporator unit and condensing unit require no communication lines unless the system is equipped with a Cold Weather Start Kit. If the system is equipped with a Cold Weather Start Kit, a low-voltage 18-2 thermostat wire will need to be run between the evaporator unit (fan coil unit) and the condensing unit.
  4. You are REQUIRED to install a drain line to remove condensation from the evaporator unit (fan coil unit).
  5. The warranty is not active until a warranty checklist has been received, reviewed, and approved.
  6. The system is intended for use in properly designed and constructed wine cellars. Hire a professional wine storage consultant with a valid contractor's license to build your wine cellar.
  7. WhisperKOOL requires that all split systems be installed by a certified HVAC-R technician only. NATE or equivalent is recommended.

If you encounter a problem with your WhisperKOOL system, please refer to the Troubleshooting Guide. If you have any further questions or concerns, or need assistance, please contact WhisperKOOL's Customer Service at 1-800-343-9463. Please be sure all testing has been completed prior to contacting Customer Service. Please have your results ready for your representative.

RECEIVING & INSPECTING THE SYSTEM

Upon receiving your WhisperKOOL unit:

  • Use caution when lifting and check package for damage.
  • Lift only at the designated hand-hold locations on the shipping container, or fully support the unit from underneath. A shipment may include one or more boxes containing accessories.
    • Before opening the container, inspect the packaging for any obvious signs of damage or mishandling.
  • Write any discrepancy or visual damage on the bill of lading before signing.
  • Allow the condensing unit to sit for 24 hours prior to start-up. The condensing unit can be placed in the installation location, piped and evacuated during this time.

Note: WhisperKOOL units are manufactured in the USA and tested prior to shipment.

  • Review the packing slip to verify contents
  • Check the model number to ensure it is correct.
  • Check that all factory options ordered are listed.

If any items listed on the packing slip do not match your order information, contact WhisperKOOL Customer Service immediately.

Check all shipped boxes for the following contents:

Evaporator Unit (Fan Coil Unit) Box:
3D rendering of a rectangular industrial cabinet with front panel and side panels, no visible text or symbols

(1) Platinum Mini Split evaporator unit (fan coil unit)

Condensing Unit Box:
Industrial condenser unit with black compressor and copper coil (no visible text or symbols)

(1) Condensing unit

Documentation bag:

  • Mini Split Version 3 owner's manual
  • Mini Split Version 3 technician's manual
    • R-134a split system warranty checklist

Accessory kit bag:

  • Retractable bottle probe
    • KDT Plus display cable (50 feet)
    • KDT Plus wall mount bracket assembly
    • KDT Plus flush mount bracket assembly
    • KDT Plus display assembly
  • Flush mount template
    • Evaporator installation hardware bag
    • KDT Plus hardware bag

Evaporator installation hardware bag:

• (2) 1/2 " x 1/2 " nylon barbed fitting
• (1) 1/2 " barbed tee
• (1) Double-D strain relief
• (4) 3/4 " adhesive cable tie mounts
• (2) Small cable ties
• (4) #8 x 1 3/4 " hex-head screws

KDT Plus hardware bag:

• (1) 1/16 " OD grommet
• (2) 1/2 " nylon hole plug
• (4) #6 x 1" Phillips zinc Type A screw
• (4) 8-10 x 7/8" blue plastic screw anchor

Condensing unit accessory kit:

• (1) Filter drier
• (1) Sight glass

Please leave the unit in its original box until you are ready for installation. This will allow you to move the product safely without damaging it. When you are ready to remove the product from the box, refer to the installation instructions.

TIP: Save your box and all packaging materials. They provide the only safe means of transporting/shipping the unit.

QUICK REFERENCE GUIDE

Front / Side View
Evaporator unit (fan coil unit) Platinum Split *WisperKOOL Filter grille

Rear / Side View

REAR VIEW Mounting keyholes (4) THROUGH THE WALL (Option 1) Knockout for wiring Line set knockout Knockout for drain line INSIDE CELLAR (Option 2) Knockout for drain line Line set knockout Knockout for wiring

WhisperKOOL S-WKPSMINI-115-3 - QUICK REFERENCE GUIDE - 3

Compressor is on

WhisperKOOL S-WKPSMINI-115-3 - QUICK REFERENCE GUIDE - 4

Fan is on

WhisperKOOL S-WKPSMINI-115-3 - QUICK REFERENCE GUIDE - 5

Anti-Frost Cycle running

WhisperKOOL S-WKPSMINI-115-3 - QUICK REFERENCE GUIDE - 6

Alarm is present

Return to Previous Menu

View/Change Set Point Enter User Menu

Power On/Off (hold for 5 sec)

DISPLAY LAYOUT
55 ESC SET I WAVE WEIGHT LIGHT

Scroll Button Change Set Point

Scroll Button Change Set Point

Unlock Button (hold for 1 sec)

PLATINUM MINI SPECIFICATIONS

ModelMini Evaporator Unit(Fan Coil Unit)Mini Condenser(Air-Cooled Condensing Unit)
Cellar Size (cu. ft.) 500
Dimensions 20"w x 10.5"h x 13"d 11.5"w x 8.9"h x 16"d
BTUh with 90°F air enter-ing the condenser coil.1730
CFM 99 190
Refrigerant R-134a
Condensing Unit HP 1/6
Voltage Rating 115V (15-amp dedicated circuit required)
Weight (lbs) 25 38.8
AMPS (Starting/Running) 2/1 13.8/3.44
dBA5165
Line SetSuction line 3/8 " OD; liquid line 1/4 " OD
Drain Line 1/2 " ID clear plastic tubing (not included)
InstallationEvaporator unit (fan coil unit) is installed in the cellar. The condensing unit is installed up to 100 line feet away and in accordance with the installation specifications found in the technician's manual.
ThermostatDigital display
Temp. Delta55°F temperature differential(maintains proper cellar temperature when exhaust environment does not exceed 110°F)
Warranty2 years (parts and labor)

PREPARING THE WINE CELLAR

The performance and life of your system is contingent upon the steps you take in preparing the wine cellar. Improperly preparing your enclosure or incorrectly installing your unit may cause unit failure, leaking of condensation, and other negative side effects.

Wine storage professionals work with licensed contractors, refrigeration technicians, and racking companies to build well-insulated, beautiful, and protective wine cellars. WhisperKOOL has put together some useful tips to assist in the installation process. Our recommendations are meant to act as a guide in the process of building a proper enclosure. Your intended location may have specific needs which we do not address.

Wall & Ceiling Framing

Build wine cellar walls using standard 2x4 or 2x6 boards and ceiling joists without violating local or state codes in your area. As a general rule, the thicker the walls and the higher the insulation value, the more consistent your cellar temperature will be.

Insulation

Insulation is REQUIRED in order to properly use WhisperKOOL products. It is vital that all walls and ceilings be insulated to keep the cellar temperature as consistent as possible during the summer and winter months. Standard fiberglass or rigid foam insulation is normally used in cellar construction; in some cases, "blown-in" insulation is used. The R-value, or quality of insulation, is determined by the rate at which heat passes through the insulation. The higher the R-value, the more resistant the insulation is to conducting heat, and the more consistent your wine cellar's temperature will be. Using higher R-values in insulation will lower your operating costs and WhisperKOOL unit run time. (R-13 is the recommended minimum; R-19 is preferred for interior cellar walls, and R-30 for ceilings and exterior walls.)

Vapor Barrier

Water vapor creates its own pressure, separate from the ambient air pressure, and will intrude into colder/drier areas. A vapor barrier is REQUIRED in order to prevent the intrusion of water vapor and maintain the correct cellar temperature and humidity. It is recommended that 6-millimeter plastic sheeting be applied to the warm side of the cellar walls. The vapor barrier must also be applied to the outside walls and ceiling. If it is impossible to reach the outside, then the plastic must be applied from within the cellar. The most common method is to wrap the entire interior, leaving the plastic loose in the stud cavity so the insulation can be placed between each stud. All of the walls and ceiling must be wrapped in plastic for a complete vapor barrier.

In areas of high humidity, such as Southern and Gulf States, the vapor barrier will prevent infiltration of warm moist air. The moist air can cause mold to form, and standing water in drain pans promote microbial and fungal growth that cause unpleasant odors and indoor air quality problems. If mold is found, remove it immediately and sanitize that portion of the unit.

Note: High humidity significantly increases the heat load on the cooling system.

Any break in the vapor barriers (cut, nail hole, over-lapping, etc.) will cause a moisture leak and must be sealed. The electric conduit is a "duct" for vapor to travel in. The conduit should be caulked and sealed on the warm air end.

Mounting the Evaporator Unit (Fan Coil Unit)

The evaporator unit (fan coil unit) must be mounted within 18" of the top of the room in order to achieve sufficient cooling. As the room cools down, the warm air will rise to the ceiling. Mounting the unit high in the room will create a consistently cool environment by capturing the warm air and replacing it with cool air. Mounting the unit low in the room will result in a temperature variation in the room due to the unit's inability to draw warm air from the ceiling of the cellar to the unit itself, and cold air settling to the floor.

settling to the floor. Keep Clear Wine Cellar

WhisperKOOL S-WKPSMINI-115-3 - Mounting the Evaporator Unit (Fan Coil Unit) - 2

Unobstructed Airflow

Unobstructed airflow to and from the system is critical for the evaporator unit (fan coil unit) and condensing units overall performance and lifespan. A minimum of 3 feet of clearance (5 feet is ideal) on all sides is crucial. The air the fans blow needs to circulate and either dissipate or absorb heat from the space. The more air to exchange, the more efficient the system will operate.

Note: Avoid attempting to camouflage the unit. This will restrict airflow and thus the systems ability to work efficiently.

Door and Door Seal

An exterior grade (1 3/4 ") door must be installed as a cellar door. It is essential that weather stripping is attached to all 4 sides of the doorjamb. A bottom "sweep" or threshold is also required. The door must have a very good vapor seal to prevent warmer moist air from leaking into the cellar. One of the most common problems with cooling systems running continually is due to the door not sealing properly. In cases where glass doors are used and the room size is close to the recommended system size, the next larger size WhisperKOOL system should be used. This will compensate for the insulation loss due to the lower insulating rating of glass.

Isometric diagram of a room with a door, tiled walls, and airflow arrows indicating fluid or ventilation (no text or symbols)

Ventilation

The necessity of dissipating heat away from the condensing unit is critical to the unit's performance and cannot be overstated. As the system operates and cools, a greater amount of heat is generated on the condensing side of the system. Adequate ventilation is required in order to dissipate heat away from the condensing unit. If ventilation is inadequate, the exhaust will heat up the area or room and adversely affect the system's ability to cool. In some cases, it may be advisable to install a vent fan to dissipate heat within the exhaust area on the condensing side of the system. However, you must have a fresh air inlet as well.

Note: If you are unsure about having adequate ventilation in your install location, please contact us to assess your specific installation at support@whisperkool.com or 1-800-343-9463.

Evaporator unit (fan coil unit) BACK - EXHAUST SIDE 110°F MAX 55°F FRONT - WINE CELLAR Condensing unit Exterior cellar wall

Ambient Temperature Factor

The cooling system has the ability to cool a wine cellar efficiently to 55° F as long as the ambient temperature of the area that it is exhausting to does not exceed 110° F. Therefore, you want to exhaust the condensing unit in a space which will not exceed 110° F. Otherwise the system will not have the capacity to keep the wine at a desirable 55° F.

WhisperKOOL S-WKPSMINI-115-3 - Ambient Temperature Factor - 1

WARNING! Allowing your system to operate in high ambient temperatures for extended periods of time will greatly decrease the life of your system and void your warranty. The cooler the temperature of the air entering the condenser coil, the more cooling capacity the system has. The less heat gain through the common wall, the less the electricity consumption.

WhisperKOOL S-WKPSMINI-115-3 - Ambient Temperature Factor - 2

LIQUID-MEASURING THERMOSTAT SYSTEM (BOTTLE PROBE)

WhisperKOOL cooling units come with a liquid-temperature-measuring thermostat. The self-calibrating probe contains a sensor chip, which communicates back and forth with the thermostat. This results in a consistent temperature setting and accuracy. Wine should be kept at a very precise, controlled temperature and humidity. By measuring the liquid temperature rather than air, the unit will operate 75–80% of the time.

Setting up the Bottle Probe:

  1. Locate an empty wine bottle.
  2. Fill it 75% full with room-temperature tap water.
  3. Place bottle probe securely into bottle as seen in Figure 1.
  4. Place bottle off to the side of the unit in your wine cellar, with the probe level.
  5. To ensure a consistent temperature, place bottle probe approximately three (3) feet away from the air output and not in the flow of the air.

It is recommended that the bottle be placed in a central location of your wine cellar. Avoid pulling too much on the probe cord. It may become disconnected resulting in limited functionality of the unit.

Note: The thermostat can be set between 55–70°F.

Remember: The unit operates based on the temperature of the water.

Do not be misled by thermostats reading air temperature. The air temperature in the cellar will be cooler than the liquid temperature of the wine while it is reaching the optimum balanced temperature.

Figure 1 level. three air air temperature vine while it is

SYSTEM OPERATION

Initial Start-Up

When the unit is plugged in and power is sent to the controller, a beep will sound, confirming that the controller is getting power. All LEDs on the display will blink three times. Three dashes will then appear on the screen. All display LEDs will then blink three times. Once the controller has gone through the initial startup process, and all LEDs have cycled, the home screen will be displayed.

Set Point

The set point is preset at the factory to 55° F. It can be adjusted by the customer between 55-70° F in one-degree increments.

Indoor Fan Operation

The indoor fan will run when the controller is calling for cooling and turn off once the cooling cycle has ended. During the cooling cycle, the system will remove some relative humidity from the cellar. Some of the humidity that was removed can be reintroduced into the cellar by adjusting the "fan on" and "fan off" functions. (The cooling system is not equipped with a humidifier and does not add humidity.)

The FOF cycle should be shortened first. This will reduce the amount of time that the fan remains off following a cooling cycle. When the unit has completed a cooling cycle, the compressor and the condenser fan will turn off, but the indoor fan will continue to run for whatever length of time the customer has set. The Fon function may then be lengthened to allow the fan to run longer and reintroduce moisture from the evaporator coil back into the wine cellar.

For more information about fan settings, refer to the User Menu on page 16.

Anti-Short Cycle

The Anti-Short Cycle ensures that the unit will remain off for a period of five minutes after the unit has reached the set point. This allows the pressure in the refrigeration system to equalize prior to starting the compressor.

Once the solenoid relay is de-energized, the controller must wait five minutes before reenergizing the relay. This prevents the compressor from repeatedly turning off and on. If the unit is calling for cooling during this time, the compressor icon will blink, indicating that cooling is needed but the controller is waiting for the Anti-Short Cycle delay.

Anti-Frost Cycle

When the evaporator probe senses a temperature of 26° F for a duration of one minute, an Anti-Frost Cycle will be initiated. This will shut down the compressor, allowing the evaporator fan to run and melt any frost accumulation on the coil. While the Anti-Frost Cycle is running, "dEF" will be displayed on the screen. The compressor will remain off until the evaporator coil reaches 40° F, or for a maximum of one hour. The unit will then return to normal operation.

Operation in Low Ambient Temperatures

If the condensing unit is installed outdoors (where it will be exposed to low ambient temperatures), the condenser fan will cycle on and off. The purpose of the fan cycling is to maintain the system's high side pressure, which will ensure an adequate refrigeration process.

Digital Display

The display is designed to give the user the ability to adjust the set point, Fon/FOF parameters, and other settings. (See User Menu on page 16 for more details.) The bottle probe temperature is displayed by default. "dEF" will be displayed during an Anti-Frost Cycle. The bottle probe and evaporator probe temperatures can be accessed by pushing the SET button and scrolling through "Pb1" (bottle probe) and "Pb2" (evaporator probe). The light button may be used as an unlock button.

Safety Features

In the event of a faulty bottle probe, the compressor will cycle off for 10 minutes and on for 40 minutes. "E1" will be displayed on the screen.

Alarms

See "Alarm Codes" in the Controller Functions chart.

DISPLAY LAYOUT

Compressor is on Fan is on Anti-Frost Cycle running 55 °F Return to Previous Menu View/Change Set Point Enter User Menu (hold for 3 sec) Power On/Off ESC SET Unlock Button Change Set Point Scroll Button Change Set Point Unlock Button (hold for 1 sec)

CONTROLLER FUNCTIONS

Button Normal Functions
INITIAL STARTUP
UNLOCKING THE DISPLAY
ON/OFFWhisperKOOL S-WKPSMINI-115-3 - DISPLAY LAYOUT - 2
UP/DOWNWhisperKOOL S-WKPSMINI-115-3 - DISPLAY LAYOUT - 3 WhisperKOOL S-WKPSMINI-115-3 - DISPLAY LAYOUT - 4
SETWhisperKOOL S-WKPSMINI-115-3 - DISPLAY LAYOUT - 5

ICON GLOSSARY

Icon Meaning
SNOWFLAKEWhisperKOOL S-WKPSMINI-115-3 - DISPLAY LAYOUT - 6Blinking: The unit is calling for cooling, but must wait five minutes before restarting the compressor. This five-minute delay serves as an Anti-Short Cycle for the compressor's protection.Constant: The unit is in cooling mode and the condensing unit is running.
DRIPPING SNOWFLAKEWhisperKOOL S-WKPSMINI-115-3 - DISPLAY LAYOUT - 7The unit is undergoing an Anti-Frost Cycle. See System Operation page for further details.
FANWhisperKOOL S-WKPSMINI-115-3 - DISPLAY LAYOUT - 8The evaporator fan is running.
ALARMWhisperKOOL S-WKPSMINI-115-3 - DISPLAY LAYOUT - 9The alarm icon is shown when the unit encounters an issue that needs attention. Alarm codes are explained on the following page. All temperature-related alarms are blocked for the first 10 hours after the unit is plugged in to allow the system to stabilize and acclimate to the new environment.

ALARM CODES

Code Cause Solution
The following alarm codes will be displayed on the screen along with the alarm icon. (●)
E1Bottle probe is not connected Attachbottle probe to circular connector (see instructions on page 10 of the technician's manual)
Faulty bottle probe connection Locatefaulty bottle probe connection by inspecting all wiring connections between the bottle probe and the circuit board. The two-pin connector for the bottle probe should be connected to the CPB/PB1 terminal on the circuit board. If it is not connected, plug it in. If a faulty connection has been identified, correct the issue or contact customer service for further assistance.NOTE: The E1 code will not appear in the alarms menu. It will be permanently displayed on the screen.
Defective bottle probe Replace the bottle probe
E2Faulty evaporator probe connectionLocate faulty evaporator probe connection by inspecting evaporator probe wire. The two-pin connector for the evaporator probe should be connected to the CPB/PB2 terminal on the circuit board. If it is not connected, plug it in.
Defective evaporator probe Replacethe evaporator probe
E7No communication between keypad and circuit board for 60 secondsVerify that the display cable is connected to the keypad and the circuit board and is not damaged, frayed, or kinked. If problem persists, contact Customer Service for troubleshooting information.
The following alarm codes will not be displayed on the home screen. However, the alarm icon will be displayed in the event of an alarm. The alarms can be viewed in the Set Menu's ALr folder. (●)
EAUnit is not draining properly 1. Check to see that the unit is level; if not, level it2. Verify that the drain line is not clogged; if so, clear obstruction3. Ensure that the condensate pump is operatingNOTE: If the drain line is obstructed or the pump fails for some reason, and the water level in the drip tray gets too high, the unit will not operate until the water in the internal drip tray drops back below the proper level.
AH1The bottle probe is sensing a temperature that is 8°F above the set point1. Allow time for the wine to reach the desired temperature2. Ensure that the cellar is sealed properly3. Verify that the bottle probe is calibrated correctly (refer to the User Menu on the following page)4. Verify that the unit is sized correctly for the cellar
AL1The bottle probe is sensing a temperature that is 8°F below the set point1. Make sure the unit is not in cooling mode (the snowflake icon will not be illuminated)2. Add heat to the room until the wine reaches the desired temp3. Verify that the bottle probe is calibrated correctly (refer to the User Menu on the following page)
Ad2The Anti-Frost Cycle ended on time-out1. Check the evaporator coil for ice buildup. Unplug the unit and allow the coil to thaw before restarting.2. Make sure the room to which the unit is exhausting is not below 60°F3. If the unit repeatedly goes into Anti-Frost Cycles (one per minute), call Customer Service for more troubleshooting information

USER MENU

The User Menu is accessed by pressing and holding the SET button for 3 seconds. Use the UP and DOWN ARROW buttons to navigate to desired parameters. Press the SET button again to view these parameters. Press the UP and DOWN ARROW buttons to adjust a parameter.

The following parameters are available in the menu:

Parameter Description
Fdc - humidity enhancement This parameteris measured in minutes, and is preset at thefactory to 1. An increase in this parameter will increase the humidityenhancement of your cellar. This parameter should not be adjustedto zero. Adjustments should be made in increments of 5, with amaximum of 15 and a minimum of 1. After making any adjustmentsto humidity enhancement,you should wait a minimum of 3 daysbefore making any additional adjustments. This will allow sufficienttime for the cellar to acclimate to the new setting.
FOF - “fan off” This setting controls how longthe fan stays off after the set pointhas been reached. It is preset to 15 minutes. This setting shouldnot be adjusted, as most properly constructed wine cellars retainan ample amount of humidity during the “fan off” cycle. If, however,you wish to decrease the duration of the “fan off” cycle (in order toincrease the wine cellar’s relative humidity), you can adjust thissetting in the User Menu.
Fon - “fan on” The “fan on” time is preset tozero minutes. This keeps the relativehumidity of the wine cellar at a stable level. If, however, you wishto raise the relative humidity of your wine cellar, you can increasethe duration of the “fan on” cycle in increments of five (5, 10, or 15minutes). After making any adjustment to the “fan on” cycle,youshould wait a minimum of 3 days before making any additionaladjustments. This will allow sufficient time for the cellar to acclimateto the new setting.
CA1 - bottle probe (Pb1) calibrationCA1 - bottle probe (Pb1) calibration:You may use this parameterto calibrate the bottle probe to a known temperature. This param-eter can be adjusted between -12°F and 12°F. For example, if thebottle probe temperature is 58°F, and the known temperature is55°F, you can set the CA1 parameter to -3°F to match the knowntemperature.
PA2 - installer menu This menu is only accessible using a password and is not availablefor adjustment.

NOTES

TROUBLESHOOTING GUIDE

Unit has ice forming on the evaporator unit (fan coil unit)
Possible cause Solution
Evaporator filter or coil is dirty Remove the filter and wash it, then cleanthe coil with a vacuum.If coil is very dirty, use a spray bottle with a small amount of liquid dish detergent or coil cleaner. Spray coil, let set for five minutes, then flush with fresh water.
There is something blocking the supply and/or return airRemove blockage
The evaporator fan is not turning on Call a service tech to troubleshoot
The evaporator unit (fan coil unit) has not gone through its Anti-Frost sequence yetCheck the coil for surface ice. Melt with blow drier until coil is warm to the touch. Soak up water with a towel.
If evaporator unit (fan coil unit) continues to iceObserve ice formation pattern. If only part way up the coil face, the system could be low on refrigerant. If all the way up, the coil may be dirty or airflow is blocked.
Unit does not run/power up
Possible cause Solution
Evaporator Unit (Fan Coil Unit) is not plugged in Make sure the unit is plugged into an outlet
Power switch not on Turn unit on by pressing the power button on the control
Line voltage rating is incorrect for the system Check line voltage to make sure it is 110V-120V
Bottle at set point Lower set point
Thermostat not calling for coolingLower set point
Faulty thermostat or wiring Call Customer Service at 1-800-343-9463
Cellar temperature is too warm
Possible cause Solution
The temperature of the room to which the condensing unit exhausts exceeds 110°FIntake temperature must drop below 110°F
The system is undersized for the cellar Order correct size system
There is something blocking the supply and/or return air on the evaporator unit (fan coil unit) or the condensing unitRemove air flow obstruction
Evaporator Unit (Fan Coil Unit) is mounted too low in the cellarRelocate unit so the distance from the ceiling and top of the unit is no more than 18"
One or more of the fans is not turning onPlease contact the installing technician to troubleshoot
Compressor is not turning onPlease contact the installing technician to troubleshoot
Compressor keeps cycling on overloadMake sure all fans are working and there is no airflow obstruction
Poor seal around door or other areas requiring a seal (around the unit, wall joints, etc.)Make sure there are no air gaps around the door. If door seal is damaged, replace it.
Controller set too highLower the set point
Evaporator coil is frosted or iced up Observe ice formation pattern. If only part way up the coil face,evaporator unit (fan coil unit) could be low on refrigerant. If so, contact your installing technician to assist with troubleshooting.
System runs constantly
Possible cause Solution
Leaky door seal or poorly insulated cellar Fix leaky door seal and insulate cellar in accordance with this manual(page 8).
Unit leaks water
Possible cause Solution
Evaporator unit (fan coil unit) is not level Evaporator unit (fan coil unit)should be level on the wall to prevent leaking
Drain line clogged or kinked Check drain line to make sure water can flow freely
Drain is clogged, preventing water from escaping Disconnect drain and clear it out; open access door and check drain for blockage
Drain line does not have a downward slope Fix drain line so there is a downward slope from the unit to the drain
Coil is iced, causing drain pan to freeze and water to overflow Melt ice with blow drier. Soak up with a towel.
Unit runs but does not cool
Possible cause Solution
Lack of air flow Make sure fan is unobstructed and that the evaporator filter, evapora- rator coil, and condenser coil are clean and free of debris
System undersized Contact Customer Service at 1-800-343-9463
Compressor is overheating Shut system off for 1 hour to allow compessor to cool. Turn back on and check for cooler airflow out. If compressor runs, check for and clean condenser coil as possible cause of compressor overheating. If problem repeats, contact you installing technician to assist with troubleshooting.
Evaporator fan runs but compressor does not
Possible cause Solution
Running an Anti-Frost Cycle 1) If the system is maintaining the correct cellar temperature and there is a dripping snowflake symbol illuminated on the display, the system is going through an Anti-Frost Cycle. No action is required. 2) If the system is not maintaining the correct cellar temperature, this may be due to a dirty evaporator filter or coil. 3) Call the installing technician to troubleshoot, as the system may be low on charge or require an adjustment to the TXV.
Compressor and/or starting components faulty Please contact the installing technician to troubleshoot
System may be performing the WHM function Allow cooling system to revert back to cooling mode
Compressor may have overheated Shut system off for 1 hour to allow compressor to cool. Turn back on and check for cooler airflow out. If compressor runs, check for and clean condenser coil as possible cause of compressor overheating. If problem repeats, contact your installing technician to assist with troubleshooting.
Compressor runs but evaporator fan does not
Possible cause Solution
Faulty fan motorPlease contact the installing technician to troubleshoot
Faulty controllerPlease contact the installing technician to troubleshoot
Compressor short cycles
Possible cause Solution
Evaporator unit (fan coil unit) blows on bottle probeMove bottle probe to a more central location
System low on refrigerant chargePlease contact the installing technician to troubleshoot
Condensing fan motor/capacitor faultyPlease contact the installing technician to troubleshoot
Compressor and /or starting components faultyPlease contact the installing technician to troubleshoot
Humidity in cellar too low
Possible cause Solution
Not enough moistureRaise the "fan on" setting to increase the humidity level

MAINTENANCE SCHEDULE

Monthly1. Check for debris surrounding condensing unit (leaves, branches, trash, etc); remove all obstructions2. Check for unusual noise or vibration3. Check the drain line to see if it is above the waterline (if draining into a vessel)
Quarterly1. Use a vacuum with brush attachment to clean the evaporator coil; be careful not to crush coil fins when cleaning2. Remove the evaporator filter and clean with warm water3. Ensure the condensing unit is free of debris and dust4. Have a certified HVAC-R technician service the condensing unit and clean the condenser coil
Annually1. Inspect for corrosion2. Check wiring connections and integrity of cords3. Pour a 50/50 bleach solution into the drain line every spring

TECHNICAL ASSISTANCE

WhisperKOOL Customer Service is available Monday through Friday from 6:00 a.m. to 4:00 p.m. Pacific Standard Time.

The appointed customer service representative will be able to assist you with your questions and warranty information more effectively if you provide them with the following:

  • The model and serial number of your WhisperKOOL systems.
  • Location of unit and installation details, such as ventilation, ducting, construction of your wine cellar, and room size.
  • Photos of the cellar and installation location may be needed.

Contact WhisperKOOL Customer Service

1738 E. Alpine Ave

Stockton, CA, 95205

www.whisperkool.com

Email: support@whisperkool.com

Phone: 209-466-9463

US Toll Free: 1-800-343-9463

Fax: 209-466-4606

ACCESSORIES FOR COOLING UNITS

WhisperKOOL offers accessories to enhance and customize your wine cooling unit.

Exterior Housing

Protects the condensing unit from the weather elements when the unit is located outside.

Condensate Pump Kit

The condensate pump kit is designed as an automatic condensate removal pump for water dripping out of our Evaporator Unit's (Fan Coil Unit's) drain line. The pump is controlled by a float/switch mechanism that turns the pump on when approximately 21/4 " of water collects in the tank, and automatically switches off when the tank drains to approximately 11/4 ". The condensate pump kit allows the excess condensate to be pumped up to 20 ft. away from the unit.

Accessories can be purchased at www.whisperkool.com

WhisperKOOL Product Terms and Conditions Including Product Limited Warranty And Product Installation Requirements For WhisperKOOL Split System Series

ATTENTION: PLEASE READ THESE TERMS OF USE CAREFULLY BEFORE INSTALLING YOUR WHISPERKOOL COOLING SYSTEM. INSTALLING YOUR WHISPERKOOL COOLING SYSTEM INDICATES THAT YOU ACCEPT AND AGREE TO EACH OF THE TERMS AND CONDITIONS SET FORTH HEREIN ("TERMS OF USE"). IF YOU DO NOT ACCEPT THESE TERMS OF USE, YOU RISK VOIDING YOUR WARRANTY AND ASSUMING ADDITIONAL REPAIR AND REPLACEMENT COSTS.

  1. Purchase of a WhisperKOOL Cooling System assumes that the Purchaser ("End User") fully accepts and agrees to the Terms and Conditions set forth in this document. The Terms and Conditions of Sale and Owner's Manual are shipped with each unit and, if another copy is needed, replacement copies can be downloaded from the company website (whisperkool.com) or by contacting WhisperKOOL directly for a new copy. WhisperKOOL reserves the right, in its sole discretion, to change its Terms and Conditions at any time, for any reason, without notice.

  2. WhisperKOOL Product Installation and Limited Warranty

A. Purchaser of the product must arrange for the product to be installed by a certified HVAC/R technician in accordance with procedures set forth by WhisperKOOL and described in the WhisperKOOL Owner's Manual.
B. The HVAC/R technician installing the product must complete the designated portion of the Split Startup Checklist and provide licensing or certification identification number information to assist in the warranty registration process.
C. Purchaser must return the completed Split Startup Checklist to WhisperKOOL within thirty (30) days of installation of Product. The Split Startup Checklist must be approved by WhisperKOOL to activate the Limited Warranty. If the Split Startup Checklist is approved, Purchaser will be sent activation approval documents and will start receiving the benefits of the Limited Warranty throughout the warranty period. If the Split Startup Checklist is incomplete, Purchaser will be informed they have five days to complete the Split Startup Checklist and re-submit to WhisperKOOL. The Split Startup Checklist will be reviewed again, and if denied, Purchaser will be informed that they have 10 business days for corrective action. Failure to register the Product may result in loss of warranty.
D. Purchaser is responsible for the full costs of installation and any additional parts required for the proper and complete installation of the product.
E. For Split Systems returned to WhisperKOOL in accordance with the terms and conditions of the Limited Warranty, WhisperKOOL warrants against defects in material and workmanship as follows:

  1. LABOR - For a period of two (2) years commencing on the date of purchase, WhisperKOOL will, at its option and discretion, reimburse up to \$250 to the End User for cost incurred for servicing, repairing, removing or installing warranty parts. Invoice for service must be forwarded to WhisperKOOL for assessment and processing. The Split System warranty is invalid if there is attempted repair by anyone other than an HVAC/R technician approved by WhisperKOOL to service the Product.

  2. PARTS - For a period of two (2) years commencing on the date of purchase, WhisperKOOL will supply, at no charge, new or rebuilt replacement parts in exchange for defective parts. Replacement parts are warranted only for the remainder of the original warranty period.

  3. FREIGHT - For a period of two (2) years commencing on the date of purchase, if after WhisperKOOL approved evaluation the original Product failure is determined to be the cause of a manufacturers defect, and not the cause of an installation error or other cause, WhisperKOOL will cover at its option, freight for the replacement parts or Product.

The following part or cause of failure is not the responsibility of WhisperKOOL:

  • Improper voltage supply
    • Line set with screw connectors (high end and low end)
  • Leaks found at the braze points when performing pressure check
  • Unit that has been charged incorrectly
  • Incorrect tubing diameter used on line set
    • A unit that has been wired incorrectly
  • Valve stem on condenser side
  • Improper installation of P-Trap
  • Lack of P-Trap (if required)

- Condensers that are installed outdoors or in elements that would affect operation without proper cover or housing. (Housing is available from Manufacturer).

Product Warranty Limitations and Exclusions.

  1. This limited warranty does not cover cosmetic damage caused during installation, damage due to acts of God, commercial use, accident, misuse, abuse, negligence, or modification to any part of the Product. Delivery and installation of the Product, any additional parts required, as well as removal of the Product if warranty work is required, are all at the sole cost, risk and obligation of the End User.
  2. This limited warranty does not cover damage due to improper installation or operation or lack of proper maintenance of the Product, connection of the Product to improper voltage supply, or attempted repair of the Product by anyone other than a technician approved by WhisperKOOL to service the Product.
  3. This limited warranty does not cover any Product sold "AS IS" or "WITH ALL FAULTS."
  4. Product that has been replaced during warranty period does not extend the warranty period past the original date of purchase.
  5. This limited warranty is valid only in the continental United States. Sales elsewhere are excluded from this warranty.
  6. Proof of purchase of the Product in the form of a bill of sale, receipted invoice or serial number, which is evidence that the Product is within the Limited Warranty Period, must be presented by the End User to WhisperKOOL in order to obtain limited warranty service.
  7. This limited warranty is void if the factory applied serial number has been altered or removed from the Product.
  8. This limited warranty is voided if installed in an enclosure of insufficient design that does not follow the Product installation requirements stated herein and in the owner's manual.
  9. Removing the rivets from the Product's unit housing without prior authorization from WhisperKOOL voids this limited warranty.
  10. The End User must first contact WhisperKOOL Customer Service by telephone (at 1-800-343-9463) prior to attempting service on any Product still under the limited warranty; else the limited warranty is voided.
    1. This limited warranty does not cover Product being concealed by, but not limited to, vegetation, fabric, shelving, mud, snow, or dirt. Product must not be painted or limited warranty will be void.
  11. This limited warranty does not cover exposure to corroding environments such as, but not limited to, petroleum and gasoline products, cleaning solvents, caustic pool chemicals, and marine air.
  12. This limited warranty does not cover any cause not relating to Product defect.
  13. THE REPAIR OR REPLACEMENT OF THE PRODUCT AS PROVIDED UNDER THIS LIMITED WARRANTY IS THE EXCLUSIVE REMEDY OF YOU, THE END USER, AS WELL AS ANYONE ELSE IN THE CHAIN OF TITLE OF THE PRODUCT, DOES NOT START A NEW LIMITED WARRANTY TIME PERIOD, AND IS IN LIEU OF ALL OTHER WARRANTIES (EXPRESS OR IMPLIED) WITH REGARD TO THE PRODUCT. IN NO EVENT SHALL WHISPERKOOL BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL, SPECIAL OR CONTINGENT DAMAGES FOR BREACH OF ANY EXPRESS OR IMPLIED WARRANTY ON THIS PRODUCT. THE IMPLIED WARRANTIES OF MERCHANTABILITY

  14. AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY EXPRESSLY DISCLAIMED. Some states do not allow the exclusion or limitation of incidental or consequential damages, or allow limitations on how long an implied warranty lasts, so the above limitations or exclusions may not apply to you. This limited warranty gives you specific legal rights, and you may have other rights, which vary from state to state.

  15. Failure of the End User to comply with all of the Product Installation Requirements, Maintenance Requirements and End User Requirements may, at WhisperKOOL's sole discretion, void this limited warranty.
  16. No one has any authority to add to or vary the limited warranty on this Product.

3. Maintenance Requirements

The End User is responsible for checking the coils on the condenser unit and vacuuming them every three months to maintain them free of debris. It is the End User's responsibility to clean off any accumulated dust, lint, or other debris from the front and rear intake grills; failure to do this on a regular basis will restrict the airflow and may affect the Product's ability to function properly. Periodically cleaning the Product's vents will help assure maximum cooling efficiency. The drain tube must also be checked and kept clean and free of debris and mold to maintain proper performance.

Mold is a natural living organism in the environment. It exists in the air in the form of microscopic spores that move in and out of buildings through doors, windows, vents, HVAC systems and anywhere else that air enters. Once it is discovered, mold must be addressed quickly and appropriately. Delayed or improper treatment of mold issues can result in costly and reoccurring repairs. If the End User suspects a mold problem, it is always best to hire a qualified and experienced mold remediation specialist.

4. Additional End User Costs And Responsibilities

Terms and conditions for replacing the Product that is being evaluated for limited warranty.

  1. After evaluation by a certified HVAC/R technician and the Product is found to be un-repairable in the field, contact WhisperKOOL Customer Service to arrange for replacement under the warranty guidelines. When a claim for warranty is submitted for a condenser skid, the End User must purchase a new condenser skid from WhisperKOOL at retail price. Upon installation of the new condenser skid by a certified HVAC/R Technician, the HVAC/R Technician must complete the Installation Checklist and End User must submit the Installation Checklist to WhisperKOOL Customer Service for approval. The original condenser skid must be returned within 21 days to WhisperKOOL for failure analysis. If the Installation Checklist is approved and the failure is evaluated as defective and not installation error or other reason, the End User will be refunded for the cost of the replacement skid.

  2. If the Product failure is evaluated and it is determined that it is an installation error or other reason, all costs, including shipping will be the responsibility of the End User.

The following items are not covered under any warranty and are the sole responsibility of the End User:

A. End Users should satisfy themselves that the Product they are purchasing is suitable for their particular needs and requirements, and thus no responsibility will be placed with WhisperKOOL for the End User's decisions in this regard.

B. End Users must assure that the product is installed by a certified HVAC/R technician. Failure to do so will result in Voiding the Limited Warranty.

C. It is the End User's responsibility to secure safe haven/storage for ANY AND ALL items that are being kept and stored in the End User's wine cellar, including any Product. WhisperKOOL takes no responsibility for the safety and preservation of the aforementioned items in the event that the environment becomes unsuitable to maintain a proper storage environment.

D. End User is responsible for initial installation costs, including, but not limited to, labor costs and the cost of any additional parts necessary to complete the installation.

E. End User is responsible for all costs incurred for the installation and/or removal of the Product, or any part thereof, unless such cost has been agreed by WhisperKOOL to be a warranty repair prior to the work being performed.

5. Sales and Use Tax

WhisperKOOL only collects California sales tax for orders shipped within the State of California; WhisperKOOL does not collect sales tax for orders shipped to other states. However, the Purchaser and the End User may be liable to the taxing authority in their state for sales tax and/or use tax on the Product. The Purchaser and the End User should each check with their state's taxing authority for sales and use tax regulations.

6. Customer Service and Troubleshooting

WhisperKOOL's customer service department is available to answer any questions or inquiries for End Users regarding a WhisperKOOL Product, as well as to assist in performing basic troubleshooting, Monday through Friday, from 6:00 a.m. to 4:00 p.m. PST, at telephone number 1-800-343-9463. WhisperKOOL reserves the right to have a certified, WhisperKOOL-approved, HVAC/R technician go on site and inspect the product if the initial trouble shooting warrants further investigation. WhisperKOOL Corporation is located at 1738 East Alpine Avenue, Stockton, California 95205.

7. Request for Product Evaluation and Repair Under Warranty

SPLIT SYSTEM FIELD SERVICE WARRANTY POLICY: This Policy is to clarify what falls under Warranty Service and what becomes the responsibility of the Owner. WhisperKOOL ("manufacturer") strives to provide our customers with a superior Product and we back our Product with a Two Year Limited Warranty. Please review the WhisperKOOL Product Terms and Conditions including Product Limited Warranty and Product Installation Requirements to ensure you have a complete understanding of our Policy and coverage of your Split System.

ARBITRATION: Any disputes arising out of or in connection with the installation and warranty of the Split System shall be referred to and finally resolved by a WhisperKOOL approved Independent Certified HVAC/R Technician. The evaluation of the Technician on all issues or matters of identifying the responsible party (WhisperKOOL or Installing Technician) shall be determined in a written report. This report will be made available to all concerned parties. If discovered under warranty, WhisperKOOL will assume the financial responsibility under their warranty guidelines. If the report finds the Owner's Installer as the responsible party, WhisperKOOL will provide all documentation to the customer to substantiate the findings. This will include the Invoice from the Independent Certified HVAC/R Technician and the written report of the findings. The Owner will become responsible for payment directly to WhisperKOOL for all charges incurred for repairs (labor, parts and shipping costs) on the Split System.

8. Miscellaneous Terms and Conditions

A. Return Policy. All return inquiries must be made within thirty (30) calendar days of the original purchase of a Product and are subject to a twenty five percent (25%) restocking fee. Shipping costs are not refundable and the Purchaser is responsible for all return shipping costs (including customs fees and duties, if applicable).
B. Security Interest. WhisperKOOL retains a security interest in each Product until payment in full.
C. Construction and Severability. Every provision of these Terms and Conditions shall be construed, to the extent possible, so as to be valid and enforceable. If any provision of these Terms and Conditions is held by a court of competent jurisdiction to be invalid, illegal or otherwise unenforceable, such provision will, to the extent so held, be deemed severed from the contract of sale between Purchaser and WhisperKOOL, and all of the other non-severed provisions will remain in full force and effect.
D. Governing Law/Choice of Forum. The laws of the State of California (without regard for conflicts of law) shall govern the construction and enforcement of the these Terms and Conditions of Sale (Sections 1 through 9 inclusive, including Product Limited Warranty And Product Installation Requirements), and further these Terms and Conditions of Sale shall be interpreted as through drafted jointly by WhisperKOOL and Purchaser. Any dispute will be resolved by the courts in and for the County of San Joaquin, State of California, and all parties, WhisperKOOL, Purchaser and End User, hereby irrevocably submit to the personal jurisdiction of such courts for that purpose. No waiver by WhisperKOOL of any breach or default of the contract of sale (including these Terms and Conditions of Sale) concerning a Product will be deemed to be a waiver of any preceding or subsequent breach or default.
E. Correction of Errors and Inaccuracies. These Terms and Conditions may contain typographical errors or other errors or inaccuracies. WhisperKOOL reserves the right to correct any errors, inaccuracies or omissions, and to change or update these Terms and Conditions, at any time without prior notice.

9. Questions, Additional Information And Technical Assistance

A. Questions. If you have any questions regarding these Terms and Conditions or wish to obtain additional information, contact us via phone at 1-800-343-9463 or please send a letter via U.S. Mail to:

Customer Service

WhisperKOOL Corporation

1738 E Alpine Ave

Stockton, CA 95205

Email: support@whisperkool.com

Web: www.whisperkool.com

B. Technical Assistance. WhisperKOOL Customer Service is available Monday through Friday from 6:00 a.m. to 4:00 p.m. PST. The Customer Service representative will be able to assist you with your questions and warranty information more effectively if you provide them with the following:

  1. The model and serial number of your WhisperKOOL UNIT.
  2. The location of the system and installation details, such as ventilation, construction of your wine cellar, and room size.

Model Serial Number

Installed by ____ Date ____

WhisperKOOL™

WhisperKOOL

1738 E. Alpine Ave

Stockton, CA 95205

1(800) 343-9463

www.whisperkool.com

Table of contents Click a title to access it
Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : WhisperKOOL

Model : S-WKPSMINI-115-3

Category : Refrigerator