Product Type Piezoelectric Request-to-Exit Pushbutton
Model SD-6176-SSVQ (Slimline Plate with Manual Override)
Operating Voltage 12~24 VDC
Contact Rating 2.5A @ 24 VAC/VDC (relay: 5A @ 24VDC)
Output Type Relay with two independently programmable outputs (NO/NC)
Output Modes Timed (1~30 seconds) or Toggle
LED Ring Colors Standby: Red (default) or Green; Active: Green (default) or Red (configurable)
Buzzer Output Configurable ON/OFF via jumper
IP Rating IP65 (weatherproof for indoor/outdoor use)
Operating Temperature 32°F to 158°F (0°C to 70°C)
Plate Material Stainless steel
Weight (Slimline with Override) 3.1 oz (88 g)
Manual Override Yes (separate button for power failure)
Installation Requirement Waterproof backbox for weatherproof installation
Compliance Must comply with local egress and locking codes
Warranty 1 year from date of sale to original customer

Frequently Asked Questions - SD-6176-SSVQ Seco-Larm

What is the SD-6176-SSVQ used for?
It is a piezoelectric request-to-exit pushbutton designed for indoor or outdoor use, typically to release an electromagnetic lock or trigger an alarm when pressed.
How do I wire the manual override button?
Connect the included wires between the NO and COM terminals of the override button and the Output 1 or 2 terminals on the switch for N.O. operation, or between NC and COM for N.C. operation. Ensure the relay output mode matches the wiring.
Can I change the LED ring colors?
Yes, you can configure the LED ring colors using the appropriate setting. By default, the LED is red in standby and green when active. You can reverse this by turning off the default setting via the configuration option.
How do I set the output duration for timed mode?
Ensure the switch output type is set to Timer. Then gently rotate the trimpot using a Philips screwdriver. Counterclockwise decreases the time (minimum 1 second), clockwise increases it (maximum 30 seconds).
What is the difference between models like SD-6176-SSQ and SD-6176-SSVQ?
The SD-6176-SSVQ includes a manual override button for use in case of power failure to the piezoelectric pushbutton. The SD-6176-SSQ does not have this override.
Is the device weatherproof?
Yes, it has an IP65 rating, making it suitable for outdoor use. However, for a weatherproof installation, it must be mounted in a waterproof backbox and the faceplate and screws properly sealed.
What is the relay rating?
The relay is rated for 5A @ 24VDC and has two individually programmable outputs (N.O. or N.C.) that trigger simultaneously.
How do I configure the output mode (N.O. or N.C.)?
Use jumpers JP1 and JP2 on the circuit board. Place the jumper on the right for N.O. operation and on the left for N.C. operation. Each output can be set independently.
Can I use this with an electromagnetic lock?
Yes, the manual provides a sample installation with an electromagnetic lock (fail-safe) and a strobe light. Ensure proper wiring and compliance with local codes.
Where can I download the manual?
The manual is available for free download in PDF format from notice-facile.com or the Seco-Larm website. You can also request a translated version via email.

User questions about SD-6176-SSVQ Seco-Larm

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Doorbell in PDF format for free! Find your manual SD-6176-SSVQ - Seco-Larm and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. SD-6176-SSVQ by Seco-Larm.

USER MANUAL SD-6176-SSVQ Seco-Larm

Outdoor Piezoelectric

Request-to-Exit Pushbuttons

Manual

ENFORCER® EXIT SALIDA

ENFORCER® EXIT SALIDA

SD-6176-SSQ Slim|line plate "TOUCH/EXIT"

SD-6176-SS1Q Slimline plate "EXIT/SALIDA"

SD-6176-SSVQ Slimline plate, manual override

SD-6276-SSQ Single-Gang plate, "TOUCH/EXIT"

SD-6276-SS1Q | Single-Gang plate, "EXIT/SALIDA"

SD-6276-SSVQ Single-Gang plate, manual override

Features:

  • Piezoelectric push buttons for indoor or outdoor use (IP65)
  • LED ring around button changes from green to red or red to green when the button is pressed
  • Timed or toggle output

  • Includes separate manual override button in case power to piezoelectric push button fails

  • Relay rated 5A@24VDC with two individually programmable outputs (NO/NC)

ENFORCER Outdoor Piezoelectric Request-to-Exit Pushbuttons

Introduction:

Operating voltage 12\~24VDC

Contact rating 2.5A@24 VAC/VDC

Ring Standby

LED Active

Red

Green

Output time 1\~30s, Toggle

IP rating IP65

Operating temperature 32°158° F ( 0°70° C)

Plate material Stainless steel

Single-Gang

3.5-oz (99g)

Single-Gang w/ manual override

4-oz

(113g)

Weight

Slimline

2.6-oz

Slimline w/ manual override

3.1-oz

(88g)

Parts List:

1x Piezoelectric push button 2x Wires for manual override

1x Manual 2x Mounting screws

Overview:

SlimlineSingle-GangSide ViewRear View(Plastic switch cover removed)
15/8" (42mm) 23/4" (70mm) 15/8" (42mm)
LED RingBuzzeradjustRelay adjust
Piezoelectric pushbuttonTerminalblocksLED colorSelection
41/2'' (114mm)ManualOverrideButton*Output modeSelectionTimerAdjustment
ManualOverrideButton*

*SD-6176-SSVQ and SD-6276-SSVQ with Manual Override button shown, other models similar.

Installation:

  1. Prepare wiring to provide 12\~24 VDC power and connect devices to the relay outputs.
    NOTE: The device includes one relay with two outputs. Outputs trigger simultaneously but can be configured independently. To set the output modes, see Relay Output Modes on page 3.
  2. Remove the plastic cover from the rear of the switch and carefully pierce the rubber grommet.
  3. SD-6176-SSVQ and SD-6276-SSVQ: Wire the manual override button. See page 3.
  4. Wire the switch according to the diagram on the right.
  5. Connect (-) and (+) to a 12\~24 VDC power source.
  6. Connect other devices to Output 1 or 2.
  7. Replace the plastic switch cover and screw the plate onto the mounting surface
    Terminal Block

2 SECO-LARM U.S.A., Inc.

Wiring the Manual Override: SD-6176-SSVQ and SD-6276-SSVQ Only

Connect the manual override button with included wires

Wiring for N.O.:

Connect the two wires between the NO and COM terminals of the override button and the Output 1 or 2 terminals on the switch.

- + Output 1 Output 2 COM Power Supply N.O. Door Strike

Wiring for N.C.:

Connect the two wires between the NC and COM terminals of the override button and the Output 1 or 2 terminals on the switch.

- + Output 1 Output 2 COM N.C. Power Supply Door Strike

Notes:

  1. Remove the thin panel on the bottom of the plastic cover to allow wiring to pass through.
  2. There is only one relay, wiring the button to either output will allow the other output to trigger simultaneously.
  3. Do not connect the manual override button to more than one output.
  4. When wiring for either N.O. or N.C., be sure to also set the Relay Output Mode to N.O., as described below. If Relay Output Mode and override button wiring do not match, the product may not function as expected

Manual Override Button
Seco-Larm SD-6176-SSVQ - Notes: - 1

Configuring the Pushbutton:

1. Buzzer Output

Default:ON

Seco-Larm SD-6176-SSVQ - Buzzer Output - 1

Use the buzzer output jumper JP3 to program the buzzer output. Placing the jumper on the left turns buzzer output ON. Placing the jumper on the right turns buzzer outputs OFF.

2. Relay Output Mode

Default: N.O

Seco-Larm SD-6176-SSVQ - Relay Output Mode - 1

Outputs 1 and 2 can be set independently using jumpers JP1 and JP2. Note: Both outputs trigger simultaneously. Place the jumper on the right for N.O. operation and on the left for N.C. operation

3. LED Ring Colors

Default: OFF

Seco-Larm SD-6176-SSVQ - LED Ring Colors - 1

ON: LED is green while in standby, and turns red when triggered. OFF: LED is red while in standby, and turns green when triggered.

4. Switch Output Type

Default: Timer

Seco-Larm SD-6176-SSVQ - Switch Output Type - 1

TIMER: When set to TIMER, pressing the switch will trigger the relay for the set time. Set the time using the trimpot as described above. TOGGLE: When set to TOGGLE, pressing the switch will cause the relay to trigger until the switch is pressed

5. Time Adjustment

Default: 1s

Seco-Larm SD-6176-SSVQ - Time Adjustment - 1

Output duration is adjustable 1\~30 seconds. (Must be set to 'Timer' in step 4) Gently rotate the trimpot using a Philips head screwdriver. Counterclockwise decreases the output time. Clockwise increases the output time.

Sample Installation: Electromagnetic Lock (Fail-Safe) with Strobe Light

Output 1 Output 2 - + - Output 1 - + - Power Supply 12-24 VDC Power Supply Power Supply

Also Available from SECO-LARM®:

Electromagnetic Locks
Exterior view of a SECO-LARM industrial enclosure with two metallic components (no visible text or symbols)

Request-to-Exit Plates
ENFORCE® EXIT SALIDA

No-Touch Request to Exit
EMFORCE NO TOUCH EXIT

IMPORTANT WARNING: For a weatherproof installation, ensure the unit is installed in a waterproof backbox, and that the faceplate and faceplate screws are properly sealed. Incorrect mounting may lead to exposure to rain or moisture in the enclosure which could cause a dangerous electric shock, damage the device and void the warranty. Users and installers of this product are responsible for ensuring this product is properly installed and sealed.

IMPORTANT: Users and installers of this product are responsible for ensuring that the installation and configuration of this product complies with all national, state, and local laws and codes related to locking and egress devices. SECO-LARM will not be held responsible for the use of this product in violation of any current laws or codes.

WARRANTY: This SECO-LARM product is warranted against defects in material and workmanship while used in normal service for one (1) year from the date of sale to the original customer. SECO-LARM's obligation is limited to the repair or replacement of any defective part if the unit is returned, transportation prepaid, to SECO-LARM. This Warranty is void if damage is caused by or attributed to acts of God, physical or electrical misuse or abuse, neglect, repair or alteration, improper or abnormal usage, or faulty installation, or if for any other reason SECO-LARM determines that such equipment is not operating properly as a result of causes other than defects in material and workmanship. The sole obligation of SECO-LARM and the purchaser's exclusive remedy, shall be limited to the replacement or repair only, at SECO-LARM's option. In no event shall SECO-LARM be liable for any special, collateral, incidental, or consequential personal or property damage of any kind to the purchaser or anyone else.

NOTICE: The SECO-LARM policy is one of continual development and improvement. For that reason, SECO-LARM reserves the right to change specifications without notice. SECO-LARM is also not responsible for misprints. All trademarks are the property of SECO-LARM U.S.A., Inc. or their respective owners. Copyright © 2019 SECO-LARM U.S.A., Inc. All rights reserved.

SECO-LARM® U.S.A., Inc.

16842 Millikan Avenue, Irvine, CA 92606 Website: www.seco-larm.com

Phone: (949) 261-2999 | (800) 662-0800 Email: sales@seco-larm.com

Seco-Larm SD-6176-SSVQ - SECO-LARM® U.S.A., Inc. - 1

PIHWK1

Order Part# xxx-xxx%

MI_SD-6x76-SSxQ_190628.docx

4 SECO-LARM U.S.A., Inc.

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : Seco-Larm

Model : SD-6176-SSVQ

Category : Doorbell