| Product Type | Touchscreen Monitor |
| Model | CB-TOUCH12-T |
| Brand | Black Box |
| Display Size | 12.1 inches (diagonal) |
| Panel Type | TFT LCD with LED backlight |
| Resolution | 1024 x 768 (XGA) |
| Touch Technology | Resistive touch (single-touch) | Aspect Ratio | 4:3 |
| Brightness | 350 cd/m² (typical) |
| Contrast Ratio | 500:1 (typical) |
| Viewing Angles | 160° horizontal, 140° vertical |
| Video Inputs | VGA (D-Sub), DVI-D |
| Touch Interface | USB Type-B |
| Power Supply | 12V DC, 3A (external power adapter) |
| Power Consumption | ≤ 20W typical |
| VESA Mount | 75 x 75 mm |
| Dimensions (W x H x D) | Approx. 317 x 259 x 42 mm (without stand) |
| Weight | Approx. 2.2 kg (net) |
| Operating Temperature | 0°C to 50°C |
| Storage Temperature | -20°C to 60°C |
| Safety Certification | CE, FCC Class A |
| Cleaning Instructions | Use a soft, dry, lint-free cloth; mild screen cleaner if needed. |
| Spare Parts / Repairability | Contact Black Box support for replacement power adapters or touch controller. |
| Warranty | 2 years (standard) |
Frequently Asked Questions - CB-TOUCH12-T Black Box
User questions about CB-TOUCH12-T Black Box
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
Download the instructions for your Monitor in PDF format for free! Find your manual CB-TOUCH12-T - Black Box and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. CB-TOUCH12-T by Black Box.
USER MANUAL CB-TOUCH12-T Black Box
ControlBridge Wired Touch Panel Desk
User Manual
Control and Manage Critical Systems using the ControlBridge Wired Touch Panel Desk along with the ControlBridge Processor.

Trademarks Used in this Manual
Black Box and the Double Diamond logo are registered trademarks of BB Technologies, Inc.
Windows is a registered trademark of Microsoft Corporation in the United States and/or other countries
Any other trademarks mentioned in this manual are acknowledged to be the property of the trademark owners.
We're here to help! If you have any questions about your application or our products, contact Black Box Tech Support at 877-877-2269 or go to blackbox.com and click on "Talk to Black Box."
You'll be live with one of our technical experts in less than 60 seconds.
Federal Communications Commission and Industry Canada Radio Frequency Interference Statements
This equipment generates, uses, and can radiate radio-frequency energy, and if not installed and used properly, that is, in strict accordance with the manufacturer's instructions, may cause interference to radio communication. It has been tested and found to comply with the limits for a Class A computing device in accordance with the specifications in Subpart B of Part 15 of FCC rules, which are designed to provide reasonable protection against such interference when the equipment is operated in a commercial environment. Operation of this equipment in a residential area is likely to cause interference, in which case the user at his own expense will be required to take whatever measures may be necessary to correct the interference.
Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
This digital apparatus does not exceed the Class A limits for radio noise emission from digital apparatus set out in the Radio Interference Regulation of Industry Canada.
Black Box Network Services shall not be liable for damages of any kind, including, but not limited to, punitive, consequential or cost of cover damages, resulting from any errors in the product information or specifications set forth in this document and Black Box Network Services may revise this document at any time without notice.
- Specifications....6
- Overview 7
2.1 Introduction....7
2.2 Features....7
2.3 What's Included 8
2.4 Hardware Description....8
2.4.1 ControlBridge 7" Wired Touch Panel Desk (CB-TOUCH7-T) 8
2.4.2 ControlBridge 12" Wired Touch Panel Desk (CB-TOUCH12-T)....9
- Installation....10
3.1 Mounting 10
3.2 Cleaning the Touch Panel....10
3.3 Connection....11
3.3.1 Ethernet....11
3.3.2 Direct PC Connection....12
- Windows Local Network Settings....13
- Download User Application....15
5.1 Overview 15
5.2 Using ControlBridge Builder 15
5.3 Using Admin Control Panel 16
- Factory Default and System Default....17
- On Screen Display 18
7.1 Access On Screen Display....18
7.2 Startup Menu 18
7.3 Settings 18
7.4 Status 19
7.5 IP Settings....19
7.6 Date/Time 20
7.7 Applications....20
7.8 Exit 21
- Admin Control Panel 22
8.1 Login 22
8.2 Configuration 22
8.3 Settings 23
8.4 SMTP 24
8.5 Date and Time....24
8.6 Applications....25
8.7 File Storage....26
8.8 E-mail 27
8.9 Settings 27
8.10 System 28
8.11 Password 29
8.12 Backup....30
8.13 Reset....32
8.14 License 32
1. Specifications
Product code CB-TOUCH7-T CB-TOUCH12-T
| Display type Color a-Si TFT LCD with LED backlit | Color a-Si TFT LCD with LED backlit | |
| Display size 7" (177.8 mm) diagonal 12.1" (307.3 mm) diagonal | ||
| Resolution 1280 x 800 pixels 1280 x 800 pixels | ||
| Viewing angle ±80° horizontal, ±80° vertical ±80° horizontal, ±80° vertical | ||
| Touch overlay Projected capacitive, edge-to edge glass | Projected capacitive, edge-to edge glass | |
| Sensors Light and proximity Light and proximity | ||
| Audio Microphone and speakers Microphone and speakers | ||
| Memory | RAM 512 MB, microSD Card min. 8 GB | RAM 512 MB, microSD Card min. 8 GB |
| Network Wired 10/100 BaseT Ethernet | Wired 10/100 BaseT Ethernet | |
| Power supply | PoE, IEEE 802.3af / Class 0 | PoE+, IEEE 802.3at / Class 4 |
| Enclosure | Aluminium, glass Integrated tabletop stand | Aluminium, glass Integrated tabletop stand |
| Dimensions | 199 x 115 x 97 mm | 320 x 192 x 153 mm |
| Weight | 0.8 kg | 2.4 kg |
| Included accessories | PoE power supply, Ethernet cable | PoE+ power supply, Ethernet cable |
2. Overview
2.1 Introduction
The ControlBridge Wired Touch Panels models include 7" and 12" screen sizes. Both models provide multimedia integration, lighting automation, security monitoring, entertainment integration, and meeting and presentation control. The active matrix touch screen display supports 1280 x 800 pixels resolution for 7" and 12" screen sizes. Both models produce stunning true-color images. A Wired Ethernet connection provides easy network integration. The touch panels are equipped with Power over Ethernet (PoE for 7" and PoE+ for 12")—technology enabling an Ethernet network cable to deliver both data and power. Fully compatible with ControlBridge controllers, these touch panels provide the ultimate one-touch solution for meeting rooms, conference rooms, boardrooms, and high-tech homes
Table 2-1. Available models.
| Product Code Description |
| CB-TOUCH7-T Wired tabletop touch panel 7" |
| CB-TOUCH12-T Wired tabletop touch panel 12" |
2.2 Features
- Wired tabletop and built-in touch panels
- 7" and 12" active matrix touch screen displays
- Resolution 1280 x 800 pixels for 7" and 12"
- Colors 32-bit (True-Color), transparency 8-bit Alpha blending
• Wired Ethernet communication
• Power over Ethernet power supply
• Built-in microphone and speakers
• Built-in light and proximity sensors
• Real time clock (RTC) for scheduling applications - Aluminium enclosure, aluminium front panel for built-in models
- Bi-directional control of any IP enabled products through Ethernet port
- Web server and Admin Control Panel for setup through a standard web browser
- Programming
NOTE: Programming: The touch panels must be programmed using ControlBridge Builder.
2.3 What's Included
Table 2-2. Package contents.
| CB-TOUCH7-T | CB-TOUCH12-T | |
| PoE Adapter 1 | ||
| PoE+ Adapter 1 | ||
| Ethernet cable 1 1 | ||
| Power cable 1 1 | ||
| Cleaning tissue 1 1 | ||
| Declaration of Conformity 1 1 | ||
| Data Sheet 1 1 | ||
| ControlBridge System Connector Wiring | 1 | 1 |
2.4 Hardware Description
2.4.1 ControlBridge 7" Wired Touch Panel Desk (CB-TOUCH7-T)


Figure 2-1. CB-TOUCH7-T.
2.4.2 ControlBridge 12" Wired Touch Panel Desk (CB-TOUCH12-T)

Figure 2-2.CB-TOUCH12-T.
Table 2-3. CB-TOUCH7-T and CB-TOUCH12-T components.
| Component Description | |
| Microphone The microphone is for future use. The functionality depends on a firmware version. | |
| Proximity sensor The Motion sensor resumes touch panel from Backlight Saver mode. Enable/Disable this function using On-Screen Display or Admin Control Panel. | |
| Light Sensor The Light Sensor automatically adjusts display backlight according ambient light level.This function has to be enabled using On-Screen Display or Admin Control Panel. | |
| Touch-screen display Touch-screen display with active matrix color LCD and resistive touch membrane overlay. | |
| Speakers Use the built-in stereo speakers to play sounds stored in the touch panels. | |
| System Default Button When you press this button, the system resets to factory defaults. For details, see ythe Factory Default and System Default chapter. You will need to use a thin screwdriver to press this button. | |
| Network Connector The 10/100BASE-T LAN is a standard network connection equipped with Power over Ethernet an using RJ-45 connector. For more details see the Connection chapter. | |
3. Installation
3.1 Mounting
Desktop models can be placed on any flat surface. To install, follow these steps:
- Don't forget to prepare the proper bushing for the cable including a standard connector. The bushing should have a minimum diameter of approximately 20mm for the Ethernet connector.
- Install the network cable as described on the following picture and connect the network connector.

Figure 3-1. Connecting the ControlBridge Wired Touch Panel to the network.
- Place the touch panel on a table.
3.2 Cleaning the Touch Panel
Clean the touch panel screen overlay after each day's use.
You will need:
1 Two clean, soft texture cloths (cotton).
2. Spray bottle of cleaning solution without alcohol (window cleaner).
3. Clean aluminium parts using a special cleaning solution.
Follow these steps:
- Turn the touch panel off.
- Spray a small amount of the cleaning solution onto one of the cloths.
- Clean the touch panel overlay with the damp cloth.
- Wipe the touch panel overlay with the dry cloth.
3.3 Connection
3.3.1 Ethernet
The standard 10/100BASE-T LAN uses an RJ-45 connector. It does not autosense polarity, which means it does not recognize straight through cable or cross-over cable. To connect directly to the PC, you must use cross-over cable; to connect directly to an toEthernet switch, use straight through cable. The length of the Ethernet cable that connects touch panel to the network must not exceed 328 feet (100 meters).
Power over Ethernet is fully compatible with:
- IEEE 802.3af (PoE) standard for 7" model
- IEEE 802.3at (PoE Plus) standard for 12" model
Power over Ethernet integrates data and power on the same wires. It keeps the structured cabling safe and does not interfere with concurrent network operation.
Power over Ethernet needs compatible Ethernet switches or injectors. You can order these from Black Box or another equipment manufacturer.
Ethernet without PoE Infrastructure

Figure 3-2. Installing the ControlBridge Touch Panel in an environment without PoE infrastructure.
Ethernet with PoE Infrastructure

Figure 3-3. Installing the ControlBridge Touch Panel in an environment with PoE infrastructure.
Table 3-1. PoE/PoE+ connector pinout.
| RJ-45 Pin Signal CAT5 Cable Color | |||
![]() | 1 TX_D1+ and PoE White / Orange | ||
| 2 TX_D1- and PoE Orange | |||
| 3 RX_D2+ and PoE White / Green | |||
| 4 | PoE +/- 48 V | Blue | |
| 5 White / Blue | |||
| 6 RX-D2- and PoE Green | |||
| 7 | PoE Common | White / Brown | |
| 8 Brown | |||
3.3.2 Direct PC Connection
The touch panel models are equipped with PoE power supply (7" models) or PoE+ power supply (12" models). That means one CATx cable is used for power supply and for data.
Make sure you use:
- PoE Adapter for 7" model
- PoE+ Adapter for 12" model
Follow these steps:
- Attach one end of an RJ-45 Ethernet straight-through cable to the LAN port on the ControlBridge touch panel and attach the other end of this cable to the OUT port of a PoE (or PoE+) Adapter.
- Attach one end of an RJ-45 Ethernet straight-through cable to the IN port of the PoE (or PoE+) Adapter and attach the other end of this cable to the LAN port of your computer.
- Attach the power supply to the PoE (PoE+) adapter.

flowchart
graph TD
A["Monitor with network interface"] --> B["Ethernet cable straight-through"]
B --> C["PoE Adapter for 7" models\nPoE+ Adapter for 12" models"]
C --> D["Ethernet cable crossed-over"]
D --> E["Laptop"]
Figure 3-4. Direction PC connection.
4. Windows Local Network Settings
For Windows® 7, follow these steps:
-
Start Windows 7.
-
Click Start.
-
Enter ncpa.cpl to the Search Box and press Enter. Following window is displayed.

Figure 4-1. Windows 7 screen.
For Windows XP, follow these steps:
- Start Windows XP.
- Click Start, then click Control Panel choose the option to switch to Classic View.
- Double-click Network Connections.

Figure 4-2. Windows XP screen.
Follow these steps:
- Right-click on the network adapter used to connect to the touch panel and then right-click and select Properties.
- Select Internet Protocol (TCP/IP) and click the Properties button.

Figure 4-3. General tab.
- Select the "Use the following IP address" option. Set the IP address to 192.168.1.1 (or another address different from 192.168.1.127 and from 192.168.1.128) and Subnet mask to 255.255.255.0. Leave other options unchanged and click OK.

Figure 4-4. TCP/IP Properites screen.
5. Download the User Application
5.1 Overview
A user control application is dedicated to control and it is programmed by ControlBridge Builder programming tools.
5.2 Using ControlBridge Builder
Follow these steps:
- Connect the touch panel to your computer as described in the PC Connection chapter.
- Run ControlBridge Builder on your PC.
- Open the appropriate project in ControlBridge Builder. Make sure that the touch panel is properly inserted and configured.
- Use the Final button on the tool bar to open the Upload and Export Application dialog box.

Figure 5-1. Upload and Export Application dialog box.
- Be sure your touch panel is checked.
-
Use the Upload button to start the application upload.
-
If touch panel firmware isn't installed, it will be uploaded automatically first and then the application upload will finish.
5.3 Using Admin Control Panel
Follow these steps:
- Connect the touch panel to your computer as described in the PC Connection chapter.
- Run ControlBridge Builder on your PC.
- Open the appropriate project in ControlBridge Builder. The touch panel must be properly inserted and configured.
- Use the Final tool bar button to open the Upload and Export Application dialog box.

Figure 5-2. Admin Control Panel screen.
- Be sure your touch panel is checked.
- Use the Export All... button to export the application and store it in the file *.cvca.
- Run the Internet browser on your PC and type in the same touch panel IP address that you see in the ControlBridge Builder project, window Properties / IP address.
- Go to the System page and check the current firmware version. If there is no actual firmware version in touch panel, upload the firmware version that corresponds to the firmware version in the ControlBridge Builder project.
- Go to the Applications page and upload the application file *.cvca.
- To start the uploaded application, press the Start button.
6. Factory Default and System Default Settings
Every device shipped from the factory is set according to table bellow, Factory Default column.
When you press the System Default button, the system default function is performed according to table bellow, System Default column. This enables you to regain connection to the touch panel in case you lose the password or do not know the IP settings.
Table 6-1. Factory default and system default settings.
| Factory Default System | Default | |||
| Configuration | Identification Name | Empty Not changed | ||
| IP settings Host name Empty Not changed | ||||
| IP address 192.168.1.128 | 192.168.1.128 | |||
| Subnet mask 255.255.255.0 | 255.255.255.0 | |||
| Default gateway 192.168.1.1 | 192.168.1.1 | |||
| DNS | Primary DNS server | Empty Not changed | ||
| Secondary DNS server | Empty Not changed | |||
| Date and time | Date and Time | Day, month, year | Real | Not changed |
| Hour, minute, second | Real | Not changed | ||
| Time zone | (GMT+1:00 CET/CEST Belgrade, ..., Prague) | Not changed | ||
| Internet clock | Use Internet clock | Not | Not changed | |
| Primary NTP server | Empty Not changed | |||
| Secondary NTP server | Empty Not changed | |||
| Applications | Empty Not changed | |||
| File storage | Empty Not changed | |||
| System | Firmware | Current version | Not changed | |
| Password | Empty Empty | |||
7. On-Screen Display
7.1 Access On Screen Display
The multifunctional button located on front panel shows the On-Screen Display. The Startup Menu is displayed automatically if no application is running.
7.2 Startup Menu

Figure 7-1. Startup Menu.
Press the Application button to download the application.
Press the On Screen Display button to launch the menu described below.
7.3 Settings

Figure 7-2. Settings menu.
The Backlight Saver automatically switches off the display backlight. Set time in minutes using - and + buttons. Time set to 0 means that Backlight Saver is disabled.
LCD Backlight sets the display backlight level.
If Adaptive Brightness is switched to Yes, the light sensor automatically adjusts the display backlight according to the ambient light level.
If Motion Sensor is switched to Yes, the Motion Sensor automatically resumes touch panel operation from Backlight Saver mode.
7.4 Status

Figure 7-3. Status screen.
This page shows the current status of the touch panel.
7.5 IP Settings

Figure 7-4. IP settings screen.
Use this page to set the communication parameters for your touch panel. The touch panel uses standard internet protocol (IP) communication parameters. You can reset certain parameters. On start up, this page will display the current IP address. Carefully note this address information (and any changes you elect to make to the IP address, subnet mask, or default gateway). Enter this information into the ControlBridge Builder program written for your specific application. For control systems with more than one unit, a unique IP address must be given to each ControlBridge unit.
Select the appropriate field using the Edit button and then use the numeric keypad.
Be sure to click the Apply button for any changes to become effective.
7.6 Date/Time

Figure 7-5. Date/Time screen.
Use this page to set the Date/Time parameters.
You can set the current date and time. Select appropriate field using the Edit button and then use the numeric keypad.
Select the time zone from the drop-down box.
The rest of the page is used for to synchronize the ControlBridge Unit's date and time with an internet clock. Select Yes to Use Internet clock. Next, enter the IP addresses (or complete address name) of the primary and secondary NTP servers.
7.7 Applications

Figure 7-6. Applications screen.
Use this screen to select, start, and stop uploaded applications. All uploaded applications are listed on this page.
Select the application and press the Start button. A "running flag" denotes the active application. The active application starts automatically after you switch on the unit. You can stop the running application by pressing the Stop button.
Files are uploaded from a personal computer to the touch panel using ControlBridge Builder software or using Admin Control Panel.
7.8 Exit

Figure 7-7. Exit screen.
8. Admin Control Panel
8.1 Login
Run the Internet browser on your PC and type in the touch panel's IP address.
The factory default IP address is 192.168.1.128. The default password is empty.

Figure 8-1. Login screen.
This screen isn't displayed if the password is empty (factory default status).
If password isn't empty, you have to login first to use these web pages with your ControlBridge Unit.
Enter your password into the Password box and click the Login button to enter the ControlBridge Unit web pages.
Remember that the password is case-sensitive. To change the password, use the Password menu after you are logged in.
8.2 Configuration

Figure 8-2. Identification tab.
Each ControlBridge Unit can be identified by a unique identification name. Unique names are most useful in applications requiring more than one ControlBridge Unit. This enables programmers and installers to reference ControlBridge Units with logical, user friendly names, like "boardroom," "lobby," etc.
To set the ControlBridge Unit identity, enter the unique name you wish to use in the Name box.
Be sure to click the Apply button for any changes to become effective!
B.3 IP Settings

Figure 8-3. Configuration screen.
This page is used for establishing the communication parameters for your ControlBridge Unit.
The ControlBridge Unit uses standard internet protocol (IP) communication parameters. Certain parameters can be reset by the user. On start up, this page will display the ControlBridge Unit's given Physical address (MAC), Current IP address. Carefully note this addressing information (and any changes you elect to make to the IP address, subnet mask, or default gateway). This information must be entered into the ControlBridge Builder program written for your specific application. For control systems with more than one ControlBridge Units, a unique IP address must be given to each ControlBridge Unit.
Some control systems are "standalone" and not part of a larger network. For such "stand alone" systems, the Host name is optional. However, for control systems that are connected to a larger network, please obtain the Host name from the network administrator, and enter it into the corresponding box. DHCP is not supported in this release.
Be sure to click the Apply button for any changes to become effective!
8.4 SMTP

Figure 8-4. SMTP tab.
Use this page to set SMTP server parameters. Set a name or an address and the port of your SMTP server.
The SMTP server and port are used by the XPL2 commands EmailSend and PresetEmailSend.
Be sure to click the Apply button for any changes to become effective!
8.5 Date and Time

Figure 8-5. Current Date and Time.
Use this page to set the time clock on your ControlBridge Unit. The current date, time, and time zone are shown on the Current time line.
Select the applicable boxes to change:
• date: day/month/year,
• time: hour/minute/second.
Be sure to click the Apply button for any changes to become effective!

Figure 8-6. Time zone.
Use this page to set the time zone on your ControlBridge Unit. The current date, time, and time zone are shown on the Current time line. Select the time zone box to change the Time zone.
Be sure to click the Apply button for any changes to become effective!

Figure 8-7. Internet clock.
Use this page to synchronize the ControlBridge Unit's date and time with an internet clock. Begin by selecting the check box for Use Internet clock. Next, enter the IP addresses (or complete address name) of the primary and secondary NTP servers. Use the Primary NTP server and Secondary NTP server boxes.
Be sure to click the Apply button for any changes to the internet clock to become effective!
8.6 Applications

Figure 8-8. Applications screen.
Use this page to upload compiled ControlBridge Builder programs to your ControlBridge Unit.
All uploaded applications are listed on this page, along with their file properties: file name/file size/date. The ControlBridge Unit has a generous memory; unused free space is shown at the bottom of this page. ControlBridge Unit also permits other service functions like deleting files, downloading programs back to a personal computer, and starting/stopping specific applications.
A "running flag" denotes the active application. To stop the running application, press the Start/Stop button. To restart the stopped application, press the Start/Stop button.
To upload files from a personal computer to the ControlBridge Unit, select the desired application program and click the Upload button. To download files from the ControlBridge Unit to a personal computer, click the File name. Tp delete files, press the Delete button. Press the Total stop button to stop a running application. This application will not be automatically started after reset.
8.7 File Storage

Figure 8-9. File storage screen.
You can use the ControlBridge Unit's generous memory as an auxiliary file storage device. This is helpful for storing presets, archiving electronic manuals, pdf files, and other support documentation. Manage the file storage via the file storage page.
A list of existing files, folders, and their properties is shown. To delete a file or a folder, click the Delete button on the corresponding line. To delete all files and folders from the current folder, click the Delete All button.
To create a new folder, enter a name for the new folder, and click the Create button. To upload a file, select the desired file, and click the Upload button.
NOTE: Files are automatically compressed for the ControlBridge Unit's internal file system. Accordingly, the size of your uncompressed file before storing may not match the decrease of free space shown on the ControlBridge Unit.
8.8 E-mail

Figure 8-10. E-mail screen.
Use this page to set e-mail parameters and recipients' addresses.
You must set the SMTP server. See the Configuration/SMTP setting.
The sender Name and E-mail are addresses of your ControlBridge Unit. The sender Name and E-mail are used by the XPL2 commands EmailSend and PresetEmailSend.
The recipient Names and E-mails are addresses of recipients, where e-mails will be sent using the XPL2 command PresetEmailSend.
8.9 Settings

Figure 8-11. Settings screen.
On this page, you can set some display features.
The Backlight Saver automatically switches off the display backlight. Set Time in minutes. When you set Time to 0, that Backlight Saver is disabled.
LCD Backlight sets display backlight level.
If Adaptive Brightness is switched to Yes, the light sensor automatically adjusts display backlight according ambient light level.
If Motion Sensor is switched to Yes, the Motion Sensor resumes touch panel from Backlight Saver mode automatically.

Figure 8-12. On-screen display.
Set On-Screen Display via this page.
Type of activation is defined here as well as mode of the On Screen Display. In Advanced mode all functions are available, Basic mode is more safety (for example network settings can't be changed).
In addition, you can enable or disable some settings for On-Screen Display.
8.10 System

Figure 8-13. Firmware screen.
Use this page to update the ControlBridge Unit firmware. The Current version of firmware is shown. To upload new firmware, select the desired version and click the Upload button.
The page shows basic information about your ControlBridge Unit's hardware. The CPU type, CPU frequency, and the flash and RAM memory sizes are shown.

Figure 8-14. Format data area.
To completely clear all data and restore factory default settings, click the Format data area button.
This will remove all data, including Applications and File storage files. Configuration will be cleared, including IP address, password, and touch-screen calibration values. IP address will be restored to the default 192.168.1.128.
8.11 Password

Figure 8-15. Password screen.
You will need a case-sensitive password to login to the Admin Control Panel pages. Set a new password via the New password box. You must reenter the password in the Confirm new password box. An error message will appear if the confirmation does not match, in this case, reenter your password again in both boxes.
Finally, to implement the new password, click the Apply button.
8.12 Backup

Figure 8-16. Backup screen.
Use this page to backup applications, files and folders. The Backup copies all Applications, Application data, File storage, and Web storage to one archive. This archive is saved to the PC. To start the backup process, click the Backup button.
NOTE: To see the backed-up/restored applications, click the Applications menu. To see backed-up/restored files and folders, click the File Storage menu. Use the page to backup all applications, files, and folders.
NOTE: To see the backed-up/restored applications, click the Applications menu. To see backed-up/restored files and folders, click the File Storage menu.

Figure 8-17. Restore screen.
READ ALL IMPORTANT NOTES THAT FOLLOW BEFORE USING THIS OPERATION!
The page is used for the restoring of all applications, files and folders. Restore copies of all applications, files, and folders from a backup archive on the PC to their corresponding locations on the ControlBridge Unit.
To start the restore process, select the desired backup archive, then click the Restore button. The restore process can take up to 10 minutes, depending on the size of the files being restored.
If you want ControlBridge Unit's settings to be restored, too, check the "Restore configuration" box. You can access the ControlBridge Unit's settings via the Configuration, Date and time, and Password menus.
IMPORTANT NOTE: Actual password and IP settings will be restored, too. The restore process takes from 1 to 10 minutes, depending on the sizes of the restored files.
IMPORTANT NOTE: When restoring files, the running application stops and all applications, files, and folders currently stored in the ControlBridge Unit will be deleted! If you want to retain them, use the Backup command before the Restore command.
NOTE: To see the backed-up/restored applications, click the Applications menu. To see backed-up/restored files and folders, click the File Storage menu.
8.13 Reset

Figure 8-18. Reset screen.
To restart your ControlBridge Unit, click the Reset button.
8.14 License

Figure 8-19. License screen.
This page describes the software license.
Black Box Tech Support: FREE! Live. 24/7.
Tech support the way it should be.

natural_image
Close-up portrait of a smiling man with short hair holding a small object, against a blue gradient background (no text or symbols visible)Great tech support is just 60 seconds away at 877-877-2269 or blackbox.com.

BLACK BOX®
About Black Box
Black Box provides an extensive range of networking and infrastructure products. You'll find everything from cabinets and racks and power and surge protection products to media converters and Ethernet switches all supported by free, live 24/7 Tech support available in 60 seconds or less.
© Copyright 2016. Black Box Corporation. All rights reserved. Black Box ^® and the Double Diamond logo are registered trademarks of BB Technologies, Inc. Any third-party trademarks appearing in this manual are acknowledged to be the property of their respective owners.