Chapter 1 Description
1.1 Notice .... 3
1.2 Introduction ...... 4
1.3 Codes Read 4
1.4 Installation 4
1.5 Pin Assignment 6
1.6 Specification 8
Chapter 2 Configuration - General
2.1 Flow Chart 10
2.2 Loop of Programming 11
2.3 Factory Default Settings 11
2.4 Main Page of Configuration 12
Chapter 3 Interface and Reading Mode Selection
3.1 Interface Selection .... 13
3.2 Memory Function 13
3.3 Reading Mode Selection.... 14
Chapter 4 Communication Parameters
4.1 RS232 Mode Parameters 15
4.2 Keyboard Wedge Mode Parameters..... 17
4.3 Output Characters Parameters ..... 19
4.4 Wand Emulation Mode Parameters..... 21
4.5 OCIA Mode Parameters 22
Chapter 5 Bar Codes & Others
5.1 Symbologies Selection .... 23
5.2 UPC/EAN/JAN Parameters 26
5.3 Code 39 Parameters ...... 28
5.4 Code 128 Parameters ...... 30
5.5 Interleave 25 Parameters .... 32
5.6 Industrial 25 Parameters .... 34
5.7 Matrix 25 Parameters ...... 36
5.8 CODABAR/NW7 Parameters 38
5.9 Code 93 Parameters ...... 40
5.10 Code 11 Parameters ...... 42
5.11 MSI/PLESSEY Code Parameters ..... 44
5.12 BC412 Code Parameters .... 46
5.13 Code 2 of 6 Parameters ...... 48
5.14 Telepen Parameters 50
Chapter 6 Miscellaneous Parameters
6.1 Language Selection .... 52
6.2 Bar Code ID 54
6.3 Reading Level 57
6.4 Accuracy 57
6.5 Buzzer Beep Tone 57
6.6 Sensitivity of Continuous Reading Mode ... 58
6.7 Notebook Function 58
6.8 Reverse Output Characters 58
6.9 Set Up Deletion 59
6.10 Set Up Insertion 62
Appendix
A. Decimal Value Tables 65
B. ASCII Tables 66
C. Function Key Tables 70
Chapter 1 Description
1.1 Notice
The manufacturer shall not be liable for technical or editorial errors or omissions contained herein; nor for incidental or consequential damages in connection with the furnishing, performance, or use of this publication.
FCC Approval

This device had been test in accordance with the procedures given in ANSI C63.4 (1992) and confirmed to complies with the limits for a CLASS B digital pursuant to part 15 of the FCC Rules.
CE Standards

The CE mark as shown here indicates this product had been tested in accordance with the procedures given in European Council Directive 89/336/EEC and confirmed to comply with the European Standard EN55022:1994/A1:1995 Class B, EN 55024/1998.
1.2 Introduction
The Decoder is an advanced and versatile decoding facility for barcoding systems. It works with variety of bar code types, reading devices, and computer interfaces. It discriminates about twenty different symbologies automatically.
This menu provide an easy way to config the decoding options and interface selections by scanning bar codes listed in the menu.
1.3 Codes Read
Codes Read
ALL UPC/EAN/JAN, Code 39, Code 39 Full ASCII, Code 128, Interleave 25, Industrial 25, Matrix 25, CODABAR/NW7, Code 11, MSI/PLESSEY, Code 93, China Postage, Code32/Italian Pharmacy Others available upon request.
1.4 Installation
Unpacking –
Remove the scanner from its packing and check it for damage. If the scanner was defected in transit, please contact your vendor immediately. Be sure that you keep the packing with all accessories contains in the package for your returning of service.
Connecting the scanner –
Keyboard wedge/RS-232C/USB:
Connect the 10-pins RS-45 male connector into the bottom of the scanner and you will hear a "click" when the connection is made.
Power supply for RS-232C scanner—
There are 3 ways to supplying the power, use external +5V power supply, use optional power cable (KBDC) which taking the power from KB wedge or if the host supports +5V power from pin 9.
Installing the scanner to the Host System –
- Turn off the host system.
- Connect the power if needed.
- Connect to the proper port on the host system.
- Turn on the host system.
5.. For USB interface under DOS environment, please enable USB keyboard in Bios setting.
Switching cable –
Before removing the cable from the scanner, it is recommended that the power on the host system is off and the power supply has been disconnected from unit.
- Find the small "Pin-hole" on the bottom of the unit.
- Use a bended regular paperclip and insert the tip into the hole.
- You will head a "click", then gentle on the strain-relief of the cable and it will slide out of the scanner

natural_image
Technical line drawing of a mechanical device with exploded view and close-up views (no text or symbols)
CD-2860
1.5 Pin Assignment
A> Output Port
1. PC Keyboard Output
DIN 5 MALE DIN 5 FEMALE
Pin No. Function Pin No. Function
1 HOST CLK 1 KB CLK
2HOSTDATA2KBDATA
4 GND 4 GND
5 Vcc(+5V) 5 Vcc(+5V)


MiniDIN 6 MALE MiniDIN 6 FEMALE
Pin No. Function Pin No. Function
1 HOST DATA 1 KB DATA
3 GND 3 GND
4 Vcc 4 Vcc
5 HOST CLK 5 KB CLK


2. RS-232 Output
DB 9 Female
Pin No. Function
2 TXD
3 RXD
5 GND
7 CTS
8 RTS
Power Lead Vcc (+5V)


3. USB Interface
USB A Type Male
Pin No.
Function
1 Vcc
2
D-
3
D+
4 GND

1.6 Specification
| C D - 2 8 6 0 |
| Interface TTL, Keyboard |
| Code Read ALL UPC/EAN/JAN, Code 39, Code 39CODABAR/NW7, Code 11, MSI/PLE |
| Width of Window | 30mm |
| Depth of Field 25mm |
| Resolution |
| Ambient Light 1500Lux |
| Scan Speed 100 |
| Voltage |
| OperatingTemperature 0 | °C |
| StorageTemperature -20 | °C |
| RelativeHumidity 20% |
| Cable |
| , RS232, USB and WAND Emulation |
| Full ASCII, Code 128, Interleave 25, Industrial 25, Matrix 25, SSEY, Code 93, China Postage, Code32/Italian Pharmacy |
|
|
|
|
|
| DC +5V ± 5% |
| to 40°C (32°F to 104°F) |
| to 60°C (-4°F to 140°F) |
| to 85% (Non-Condensing) |
| Straight, 5 ft. |
Chapter 2 Configuration - General
2.1 Flow Chart

flowchart
graph TD
A["Start Configuration"] --> B["Interface Selection\nInput Port Selection\nCommunication\nParameters\nBar Codes Parameters\nMSR Parameters\nMisc .Parameters\netc."]
B --> C["Abort Configuration"]
B --> D["End Configuration"]
C --> E["Save Parameters"]
D --> E
F["Recall Parameter"] --> E
G["Set All Defaults"] --> E
2.2 Loop of Programming
The philosophy of programming parameters has been shown on the flow chart of 2.1. Basically user should
- Scan Start of Configuration.
- Scan all necessary labels for parameters that meet applications.
- Scan End of Configuration to end the programming.
- To permanently save the settings you programmed, just scan label for Save Parameters.
- To go back to the Default Settings, just scan label for Set All Defaults.
2.3 Factory Default Settings
The factory default settings are shown with < > and bold in the following sections. You can make your own settings by following the procedures in this manual. If you want to save the settings permanently, you should scan the label of "Save Parameters" in chapter 2.4, otherwise the settings will not be saved after the decoder power is off, and all settings will go back to previous settings.
By scanning "Set All Default" label, the settings will go back to the factory default settings.
2.4 Main Page of Configuration
Save Parameters

Recall Stored
Parameters

Set All Defaults

Start Configuration

End Configuration

Abort Configuration

Version Information

Save Parameters -
The parameter settings will be saved permanently.
Recall Stored Parameters -
Replace the current parameters by the parameters you saved last time.
Set All Defaults -
Set all the parameters to the factory default settings.
Abort Configuration -
Terminate current programming status.
Display the decoder version information and date code.
Chapter 3 Interface and Reading Mode Selection
3.1 Interface Selection

RS232 Mode

WAND Emulation

OCIA Mode

USB Mode

3.2 Memory Function

Disable

3.3 Reading Mode Selection

Ch.4 Communication Parameters
4.1 RS232 Mode Parameters
A> Set Up BAUD Rate

bar
| Bar | Value (%) |
|---|---|
| 600 | 70 |
| 2400 | 72 |
| <9600> | 77 |
| 38400 | 55 |
| 1200 | 71 |
| 4800 | 73 |
| 19200 | 74 |
B> Set Up Data Bits

bar
| Bit Type | Value |
|----------------------|-------|
| 7 Data Bits | % |
| <8 Data Bits | % |
| C> Set Up Stop Bits | % |
| <1 Bit | % |
| 2 Bits | % |
D> Set Up Parity

Odd

Space

Even

Mark

E> Handshaking
RTS/CTS Enable

ACK/NAK Enable

XON/XOFF Enable




4.2 Keyboard Wedge Mode Parameters A> Terminal Type

IBM PS/2 25, 30

Apple Desktop Bus(ADB)

IBM 122 Key (1)

IBM 122 Key (2)

Reserved 2

Reserved 4

IBM PC/XT

NEC 9800

IBM 5550

IBM 102 Key

Reserved 1

Reserved 3

Reserved 5

B> Upper/Lower Case

Upper Case

Lower Case

C> Send Character by ALT Method
Enable


D> Select Numerical Pad
ON


4.3 Output Characters Parameters
A> Select Terminator

B> Time-out Between Characters

4.4 Wand Emulation Mode Parameters
A> TTL Level Representation

Bar Equals Low

B> Scan Speed Selection

Slow

C> Output Format Selection