RSD-100C-24 - Power bank Mean Well - Free user manual and instructions
Find the device manual for free RSD-100C-24 Mean Well in PDF.
| Product Type | DC-DC Converter |
| Model | RSD-100C-24 |
| Brand | Mean Well |
| Output Voltage | 24V DC |
| Output Power | 100W |
| Output Current | 4.17A |
| EMI Filter | Internal |
| Terminal Type | Screw terminals (enclosed type) |
| Recommended Wire Gauge | AWG 16 to 8 (see manual table) |
| Grounding | FG must be connected to earth ground |
| Ventilation Clearance | 10-15 cm from heat sources |
| Mounting Orientation | Standard orientation; de-rating for other orientations |
| Operating Environment | Avoid high moisture and high temperature |
| Safety Compliance | China RoHS |
| Manufacturer | Mean Well Enterprises Co., Ltd. |
Frequently Asked Questions - RSD-100C-24 Mean Well
User questions about RSD-100C-24 Mean Well
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
Download the instructions for your Power bank in PDF format for free! Find your manual RSD-100C-24 - Mean Well and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. RSD-100C-24 by Mean Well.
USER MANUAL RSD-100C-24 Mean Well
A DC-DC converter is a device used to convert a DC source from one voltage level to another. Mean Well's DC-DC converters equipped with internal EMI filter stage that possess the required EMC performance.
- Installation
(1) Before commencing any installation or maintenance work, please disconnect your system from the utility. Ensure that it cannot be re-connected inadvertently!
(2) For PCB type, at least 5mm insulation distance around the unit should be kept.
(3) Allow good ventilation for the unit in use to prevent it from overheating. Also, a 10-15 cm clearance must be kept when the adjacent device is a heat source.
(4) Mounting orientations other than standard orientation or operate under high ambient temperature may increase the internal component temperature and will require a de-rating in output current. Please refer to the specification sheets to receive the optimum mounting position and information about the de-rating curve.
(5) Recommended input/output wires are shown as below.
| AWG | 18 | 16 | 14 | 12 | 10 | 8 |
| Rated Current of Equipment (Amp) | 6A | 6-10A | 10-16A | 16-25A | 25-32A | 32-40A |
| Cross-section of Lead( mm^2 ) | 0.75 | 1.00 | 1.5 | 2.5 | 4 | 6 |
| Note: Current each wire carries should be de-rated to 80% of the current suggested above when using 5 or more wires connected to the unit. | ||||||
(6) For PCB type, compatible mating housing please refers to the specifications
(7) For enclosed type, make sure that all strands of each stranded wire enter the terminal connection and the screw terminals are securely fixed to prevent poor contact.
(8) For other information about the products, please refer to www.meanwell.com for details.
● Warning / Caution !!
(1) Risk of electrical shock and energy hazard. All failure should be examined by a qualified technician. Please do not try to fix the converter by yourself!
(2) Risk of irreparable damage. Do not reverse polarity, both input and output.
(3) Please do not install converters in places with high moisture or near the water.
(4) Please do not install converters in places with high ambient temperature or near fire source. Please refer to the specifications about the maximum ambient temperature limitations.
(5) Output current and output wattage must not exceed the rated values on specifications.
(6) The ground (FG) must be connected to earth ground.
(7) For system considerations, PCB and enclosed type converters may require an additional inrush current limiting circuit to suppress high inrush current surges. If you are uncertain about that circuit, contact Mean Well.
(8) All of Mean Well's converters are designed in accordance with EMC regulations and the related test reports are available by request. Since they are belong to component power supplies and will be installed inside system enclosure, when they are integrated into a system, the EMC characteristics of the end system must be re-verified again.
Manufacturer :
MEAN WELL ENTERPRISES Co., LTD.
No.28, Wuquan 3rd Rd., Wugu Dist.,
New Taipei City 24891, Taiwan
Tel: +886-2-2299-6100
Web: www.meanwell.com
Branch Office :
China
MEAN WELL (GUANGZHOU)
ENTERPRISES Co., LTD.
2F, A Building, Yuean Industry Park,
Huangcun, Dongpu Yown, Tianhe
District, Gungzhou, China
Post Code:510660
Tel: +86-20-2887-1200
Web: www.meanwell.com.cn
U.S.A.
MEAN WELL USA, INC.
44030 Fremont Blvd., Fremont,
CA 94538, U.S.A.
Tel: +1-510-683-8886
Web: www.meanwellusa.com
Europe
MEAN WELL EUROPE B.V.
Langs de Werf 8, 1185XT
Amstelveen, The Netherlands
Tel: +31-20-758-6000
Web: www.meanwell.eu
Declaration of China RoHS Conformity
In order to reduce the impacts on the environment and take the more responsibility for protecting the earth, MEAN WELL is confirming and announcing the conformity to China RoHS, an Administrative Measures for the Restriction of the Use of Hazardous Substances in Electrical and Electronic Products.
Environment Friendly Use Period Label
![]() | Observing SJT 11364-2014, Marking for the Restricted Use of Hazardous Substances in Electronic and Electrical Products |
| Observing SJ/Z 11388-2009, General Guidelines of Environment-friendly Use Period of Electronic Information Products Appendix B, adopting table look-up to verify the Environment Friendly Use Period |
Names and Contents of Hazardous Substances Lists
| Part Name | Hazardous Substances | |||||
| Lead(Pb) | Mercury(Hg) | Cadmium(Cd) | Hexavalent chromium( Cr^6+ ) | Polybrominated biphenyls(PBB) | Polybrominated diphenyl ethers(PBDE) | |
| PCB and its components | X | O | X | O | O | O |
| Metal structure parts | X | O | O | O | O | O |
| Plastic structure parts | O | O | O | O | O | O |
| Accessories | O | O | O | O | O | O |
| Cables | X | O | O | O | O | O |
| O: The concentration of the hazardous substances within the homogeneous material of that product is less than the concentration limits set by GB/T 26572-2011.X: The concentration of the hazardous substances within the homogeneous material of that product is over the concentration limits set by GB/T 26572-2011; however, it follows the standard advised by 2011/65/EU. | ||||||