Product Type Air Conditioner
Brand Kaden
Model KCS42
Cooling Capacity 12000 BTU
Heating Function No (cooling only)
Energy Efficiency (EER) 3.0 W/W
Power Supply 220-240 V ~ 50 Hz
Noise Level (Indoor) 56 dB
Noise Level (Outdoor) 65 dB
Dimensions (Indoor Unit) 450 x 350 x 600 mm
Weight (Indoor Unit) 30 kg
Refrigerant R32
Timer Yes (24-hour programmable)
Remote Control Yes
Dehumidification Yes (1.5 L/h)
Fan Speeds 3 (Low, Medium, High)
Installation Type Portable (single hose)
Airflow 400 m³/h
Recommended Room Size 20-30 m²
Warranty 2 years
Maintenance Clean filters every month
Safety Features Overheat protection, auto shut-off
Repairability Spare parts available

Frequently Asked Questions - KCS42 Kaden

How often should I clean the air filter?
Clean the air filter every month to maintain efficiency and air quality.
What should I do if the air conditioner does not turn on?
Check the power supply and ensure the plug is securely connected. Also, verify the circuit breaker and remote control batteries.
How do I drain the water from the unit?
Most portable models use evaporative technology; however, in high humidity, manually drain via the bottom drain plug or connect a hose.
Can I use an extension cord with this air conditioner?
No, using an extension cord is not recommended due to fire risks. Plug directly into a dedicated outlet.
How do I set the timer?
Press the Timer button on the remote, then set the desired hours using the +/- buttons. Confirm with the Set button.
What does error code E1 mean?
E1 typically indicates a temperature sensor malfunction. Try resetting the unit by unplugging for 5 minutes. If persistent, contact service.
Is the installation kit included?
Yes, the package includes a window seal kit, exhaust hose, and brackets for quick installation.
How can I reduce noise from the unit?
Place the unit on a level, hard surface to minimize vibrations. Clean filters and ensure the compressor is not obstructed.
What refrigerant type does it use?
This model uses R32 refrigerant, which is environmentally friendly and efficient.
How do I switch between cooling and fan mode?
Press the Mode button on the remote repeatedly to cycle through Cool, Fan, and Dry modes. The display shows the active mode.

User questions about KCS42 Kaden

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Air conditioner in PDF format for free! Find your manual KCS42 - Kaden and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. KCS42 by Kaden.

USER MANUAL KCS42 Kaden

CASSETTE AIR CONDITIONER

Owner's Manual

KCS Series

KCS24 | KCS36 | KCS42 | KCS48

Kaden KCS42 - Owner's Manual - 1

natural_image Isometric line drawing of a layered electronic component or circuit board structure (no text or symbols)

kaden ^

Table of contents

  1. Safety precautions 4
  2. Unit specifications and features 5

Indoor unit display 5

Operating temperature 6

Other features 7

  1. Care and maintenance 8

Cleaning your indoor unit 8

Cleaning your air filter 8

Maintenance – long periods of non-use 9

Maintenance – pre-season inspection 9

  1. Troubleshooting 10

Common issues

10

Troubleshooting

11

  1. Disposal guidelines

13

Important note

Read this manual carefully before installing

or operating your new air conditioning unit.

Make sure to save this manual for future reference.

1. Safety precautions

Read safety precautions before operation and installation

Incorrect installation due to ignoring instructions can cause serious damage or injury.

The seriousness of potential damage or injuries is classified as either a WARNING or a CAUTION.

Kaden KCS42 - Read safety precautions before operation and installation - 1

This symbol indicates the possibility of personal injury or loss of life.

Kaden KCS42 - Read safety precautions before operation and installation - 2

This symbol indicates the possibility of property damage or serious consequences.

WARNINGS FOR PRODUCT USE

  • Ask an authorised technician to install this air conditioner. Inappropriate installation may cause water leakage, electric shock, or fire.
  • The warranty will be voided if the unit is not installed by a licensed person.
  • If an abnormal situation arises (like a burning smell), turn off the power supply and call a licensed installer for instructions to avoid electric shock, fire or injury.
  • Do not let the indoor unit or the remote control get wet. It may cause electric shock or fire.
  • Do not insert fingers, rods or other objects into the air inlet or outlet. This may cause injury, since the fan may be rotating at high speeds.
  • Do not use a flammable spray such as hair spray, lacquer or paint near the unit. This may cause fire or combustion.

CAUTION

  • Do not inspect the unit by yourself. Ask an authorised installer to perform the inspection.
  • To prevent product deterioration, do not use the air conditioner for preservation purposes (storage of food, plants, animals, works of art, etc.).
  • Do not touch the evaporator coils inside the indoor unit. The evaporator coils are sharp and may cause injury.
  • Do not operate the air conditioner with wet hands. It may cause electric shock.
  • Do not operate the air conditioner when using fumigant insecticides. The chemicals may become layered with the unit and endanger those who are hypersensitive to chemicals.
  • Do not let children play with the air conditioner.
  • If the air conditioner is used together with other heating devices, thoroughly ventilate the room to avoid oxygen deficiency.
  • Do not climb onto or place objects on top of the outdoor unit.
  • The air conditioner can be used by children aged 8 years and older and people with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, if they have been given instruction on how to properly and safely operate the system.
  • Do not operate the air conditioner in a wet room (e.g. bathroom or laundry room). This can cause electrical shock and cause the product to deteriorate.
  • An all-pole disconnection device which has at least 3mm separation distance in all pole and a residual current device (RCD) with the rating of above 10mA shall be incorporated in the fixed wiring according to the national rule.
  • The appliance shall be installed in accordance with national wiring regulations.
  • Children should be supervised to ensure that they do not play with the appliance.

2. Unit specifications and features

Indoor unit display

LouvreDisplay panel Air outletAir inlet

Manual button LED display Infrared receiver

MANUAL BUTTON: This button selects the mode in the following order: AUTO, FORCED COOL, OFF.

FORCED COOL MODE: In FORCED COOL mode, the Operation light flashes. The system will then turn to AUTO after it has cooled with a high fan speed for 30 minutes. The remote control will be disabled during this operation.

OFF MODE: When the panel is turned OFF, the unit turns off and the remote control is re-enabled.

Operating temperature

When your air conditioner is used outside of the following temperature ranges, certain safety protection features may activate and cause the unit to disable.

Inverter split type

COOL mode HEAT mode DRY mode
Room temperature 17°C – 32°C0°C – 30°C 10°C – 32°C
Outdoor temperature -15°C – 50°C-15°C – 24°C 0°C – 50°C

When outside temperature is below 0^ C we strongly recommend keeping the unit plugged in at all time to ensure smooth ongoing performance.

NOTE: If the air conditioner operates in excess of room relative humidity less than 80%, the surface of the air conditioner may attract condensation. Please set the vertical air flow louvre to its maximum angle (vertically to the floor), and set HIGH fan mode.

To further optimise the performance of your unit, do the following:

  • Keep doors and windows closed.
  • Limit energy usage by using TIMER ON and TIMER OFF functions.
  • Do not block air inlets or outlets.
  • Regularly inspect and clean air filters.

Other features

Default setting

When the air conditioner restarts after a power failure, it will default to the factory settings (AUTO mode, AUTO fan, 24°C (76°F)). This may cause inconsistencies on the remote control and unit panel. Use your remote control to update the status.

Auto-restart

In case of power failure, the system will immediately stop. When power returns, the Operation light on the indoor unit will flash. To restart the unit, press the ON/OFF button on the remote control. If the system has an auto restart function, the unit will restart using the same settings.

Three-minute protection feature

A protection feature prevents the air conditioner from being activated for approximately 3 minutes when it restarts immediately after operation.

Louvre angle memory function

Some models are designed with a louvre angle memory function. When the unit restarts after a power failure, the angle of the horizontal louvres will automatically return to the previous position. The angle of the horizontal louvre should not be set too small as condensation may form and drip into the machine. To reset the louvre, press the manual button, which will reset the horizontal louvre settings.

Refrigerant leak detection system

In the event of a refrigerant leak, the LCD screen will display "EC" and the LED indicator light will flash.

3. Care and maintenance

Cleaning your indoor unit

BEFORECLEANING OR MAINTENANCE

ALWAYS TURN OFF YOUR AIR CONDITIONER SYSTEM AND DISCONNECT ITS POWER SUPPLY BEFORE CLEANING OR MAINTENANCE.

CAUTION

Only use a soft, dry cloth to wipe the unit clean. If the unit is especially dirty, you can use a cloth soaked in warm water to wipe it clean.

  • Do not use chemicals or chemically treated cloths to clean the unit.
  • Do not use benzene, paint thinner, polishing powder or other solvents to clean the unit. They can cause the plastic surface to crack or deform.
  • Do not use water hotter than 40^ C to clean the front panel. This can cause the panel to deform or become discoloured.

Cleaning your air filter

A clogged air conditioner can reduce the cooling efficiency of your unit, and can also be bad for your health.

WARNING: DO NOT REMOVE OR CLEAN THE FILTER BY YOURSELF

Removing and cleaning the filter can be dangerous. Removal and maintenance must be performed by an authorised technician.

  1. Unlock the grille by pushing the two tabs towards the middle simultaneously.
  2. Unplug the display panel cable from the control box on the main body.
  3. Detach the grille from the main unit by holding the grille at a 45^ angle, lifting it up slightly and then pulling the grille forward.
  4. Remove the air filter.

  5. Clean the air filter by vacuuming the surface or washing it in warm water with mild detergent.

  6. Rinse the filter with clean water and allow it to air-dry. Do not let the filter dry in direct sunlight.
  7. Reinstall the filter.
  8. Reinstall the front grille and reconnect the display panel cable to the control box on the main body.

Press tabs to release grille

Kaden KCS42 - WARNING: DO NOT REMOVE OR CLEAN THE FILTER BY YOURSELF - 2

natural_image Simple line drawing of a faucet spraying water onto a grid-patterned surface (no text or symbols)

If using water, the inlet side should face down and away from the water stream.

Kaden KCS42 - WARNING: DO NOT REMOVE OR CLEAN THE FILTER BY YOURSELF - 3

natural_image Line drawing of a hand using a vacuum cleaner to clean or store floor tiles (no text or symbols)

If using a vacuum cleaner, the inlet side should face the vacuum.

Kaden KCS42 - WARNING: DO NOT REMOVE OR CLEAN THE FILTER BY YOURSELF - 4

AUTION

  • Before changing the filter or cleaning, turn off the unit and disconnect its power supply.
  • When removing filter, do not touch metal parts in the unit. The sharp metal edges can cut you.
  • Do not use water to clean the inside of the indoor unit. This can destroy insulation and cause electrical shock.
  • Do not expose filter to direct sunlight when drying. This can shrink the filter.

Kaden KCS42 - AUTION - 1

AUTION

  • Any maintenance and cleaning of outdoor unit should be performed by an authorised technician
  • Any unit repairs should be performed by an authorised technician.

Maintenance – long periods of non-use

If you plan not to use your air conditioner for an extended period of time, do the following:

Kaden KCS42 - Maintenance – long periods of non-use - 1
Clean all filters

Kaden KCS42 - Maintenance – long periods of non-use - 2
Turn on FAN function until unit dries out completely

Kaden KCS42 - Maintenance – long periods of non-use - 3
Turn off the unit and disconnect the power

Kaden KCS42 - Maintenance – long periods of non-use - 4
Remove batteries from remote control

Maintenance – pre-season inspection

After long periods of non-use, or before periods of frequent use, do the following:

Kaden KCS42 - Maintenance – pre-season inspection - 1
Check for damaged wires

Kaden KCS42 - Maintenance – pre-season inspection - 2
Clean all filters

Kaden KCS42 - Maintenance – pre-season inspection - 3

Kaden KCS42 - Maintenance – pre-season inspection - 4
Replace batteriesCheck for leaks

Kaden KCS42 - Maintenance – pre-season inspection - 5

Kaden KCS42 - Maintenance – pre-season inspection - 6
Make sure nothing is blocking all air inlets and outlets

4. Troubleshooting

SAFETY PRECAUTIONS

If any of the following conditions occurs, turn off your unit immediately!

  • The power cord is damaged or abnormally warm
  • You smell a burning odour
  • The unit emits loud or abnormal sounds
  • A power fuse blows or the circuit breaker frequently trips
    • Water or other objects fall into or out of the unit

DO NOT ATTEMPT TO FIX THESE YOURSELF! CONTACT AN AUTHORISED TECHNICIAN IMMEDIATELY!

Common issues

The following are not malfunctions and in most situations will not require repairs.

Issue Possible causes

Unit does not turn on when the ON/OFF button is pressedThe unit has a 3-minute protection feature that prevents the unit from overloading. The unit cannot be restarted within three minutes of being turned off.
Cooling and heating models: If the Operation light and PRE-DEF (Pre-heating/ Defrost) indicators are lit up, the outdoor temperature is too cold and the unit's anti-cold wind is activated in order to defrost the unit.
In Cooling-only models: If the “Fan Only” indicator is lit up, the outdoor temperature is too cold and the unit's anti-freeze protection is activated in order to defrost the unit.
The unit changes from COOL/HEAT mode to FAN modeThe unit may change its setting to prevent frost from forming on the unit. Once the temperature increases, the unit will start operating in the previously selected mode again.
The set temperature has been reached, at which point the unit turns off the compressor. The unit will continue operating when the temperature fluctuates again.
The indoor unit emits white mistIn humid regions, a large temperature difference between the room's air and the conditioned air can cause white mist.
Both the indoor and outdoor units emit white mistWhen the unit restarts in HEAT mode after defrosting, white mist may be emitted due to moisture generated from the defrosting process.
The indoor unit makes noisesA rushing air sound may occur when the louvre resets its position.
A squeaking sound is heard when the system is OFF or in COOL mode. The noise is also heard when the drain pump (optional) is in operation.
A squeaking sound may occur after running the unit in HEAT mode due to expansion and contraction of the unit's plastic parts.
Both the indoor unit and outdoor unit make noisesLow hissing sound during operation: This is normal and is caused by refrigerant gas flowing through both indoor and outdoor units.
Low hissing sound when the system starts, has just stopped running, or is defrosting: This noise is normal and is caused by the refrigerant gas stopping or changing direction.
Squeaking sound: Normal expansion and contraction of plastic and metal parts caused by temperature changes during operation can cause squeaking noises.

Issue Possible causes

The outdoor unit makes noisesThe unit will make different sounds based on its current operating mode.
Dust is emitted from either the indoor or outdoor unitThe unit may accumulate dust during extended periods of non-use, which will be emitted when the unit is turned on. This can be mitigated by covering the unit during long periods of inactivity.
The unit emits a bad odourThe unit may absorb odours from the environment (such as furniture, cooking, cigarettes, etc.) which will be emitted during operations.
The unit's filters have become mouldy and should be cleaned.
The fan of the outdoor unit does not operateDuring operation, the fan speed is controlled to optimise product operation.

Troubleshooting

When troubles occur, please check the following points before contacting your qualified technician.

Problem Possible causes Solution
Poor cooling performanceTemperature setting may be higher than ambient room temperatureLower the temperature setting
The heat exchanger on the indoor or outdoor unit is dirtyContact a qualified service technician
The air filter is dirty Remove the filter and clean it according to instructions
The air inlet or outlet of either unit is blocked Turn the unit off, remove the obstruction and turn it back on
Doors and windows are open Make sure that all doors and windows are closed while operating the unit
Excessive heat is generated by sunlight Close windows and curtains during periods of high heat or bright sunshine
There are too many sources of heat in the room (people, computers, electronics, etc.)Reduce amount of heat sources
Low refrigerant due to leak or long-term use Contact a qualified service technician
The unit is not workingPower failure Wait for the power to be restored
The power is turned off Turn on the power
The fuse is burned out Contact a qualified service technician
Remote control batteries are deadReplace batteries
The unit's 3-minute protection has been activatedWait three minutes after restarting the unit
Timer is activated Turn timer off
The unit starts and stops frequentlyThere's too much or too little refrigerant in the systemContact a qualified service technician
Incompressible gas or moisture has entered the systemContact a qualified service technician
System circuit is blocked Contact a qualified service technician
The compressor is broken Contact a qualified service technician
The voltage is too high or too low Contact a qualified service technician
Poor heating performanceThe outdoor temperature is extremely low Contact a qualified service technician
Cold air is entering through doors and windows Make sure that all doors and windows are closed during use
The refrigerant level has become low due to a leak or long-term useContact a qualified service technician
Indicator lamps continue flashingThe unit may stop operation or continue to run safely. If the indicator lamps continue to flash or error codes appear, wait for about 10 minutes. The problem may resolve itself.
Error code appears and begins with the following letters in the window display of the indoor unit:• E(x), P(x), F(x)• EH(xx), EL(xx), EC(xx)• PH(xx), PL(xx), PC(xx)If not, disconnect the power, then connect it again. Turn the unit on.If the problem persists, disconnect the power and contact your nearest qualified service technician.

NOTE: If your problem persists after performing the checks and diagnostics above, turn off your unit immediately and contact your qualified service technician.

5. Disposal guidelines

The appliance contains refrigerant and other potentially hazardous materials. When disposing of this appliance, the law may require special collection and treatment. Decommissioning of this air conditioner must be performed by a trade qualified licensed technician so as to comply with Australian law.

Emitting some refrigerants to the atmosphere is illegal and is detrimental to the environment.

Kaden KCS42 - Disposal guidelines - 1

AUTION

This air conditioner contains high pressure refrigerant and oil.

Do not dispose of this product as a household waste or unsorted municipal waste.

When disposing of this appliance, you have the following options:

  • Dispose of the appliance at designated municipal electronic waste collection facility.
  • Sell the appliance to a certified scrap metal dealer.

NOTE: Disposing of this appliance in the forest or other natural surroundings endangers your health and is bad for the environment.