3RW4037-1BB15 - Industrial Automation SIEMENS - Free user manual and instructions
Find the device manual for free 3RW4037-1BB15 SIEMENS in PDF.
| Product Type | SIRIUS 3RW40 Soft Starter |
| Model | 3RW4037-1BB15 |
| Rated Operational Current (Ie) | 37 A |
| Rated Operational Voltage (Ue) | 400 V AC |
| Control Supply Voltage | 24 V DC |
| Frequency | 50/60 Hz |
| Dimensions (W x H x D) | 70 mm x 150 mm x 200 mm |
| Weight | 1.5 kg |
| Degree of Protection | IP20 |
| Ambient Temperature (Operation) | -25°C to +60°C |
| Main Functions | Soft start, soft stop, motor protection, bypass operation |
| Parameter Setting | Via integrated keypad or software (SIRIUS Soft Starter ES) |
| Communication Interface | PROFIBUS DP (optional module) |
| Maintenance | Periodic inspection of connections and fan; clean with dry cloth |
| Cleaning | Use a dry, lint-free cloth; avoid solvents |
| Safety Features | Overload protection, short-circuit protection, phase failure detection |
| Spare Parts | Replaceable fan, terminal clamps |
| Repairability | Modular design; components replaceable by qualified personnel |
| Standards | IEC 60947-4-2, UL 508, CSA C22.2 |
| Brand | Siemens |
Frequently Asked Questions - 3RW4037-1BB15 SIEMENS
User questions about 3RW4037-1BB15 SIEMENS
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
Download the instructions for your Industrial Automation in PDF format for free! Find your manual 3RW4037-1BB15 - SIEMENS and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. 3RW4037-1BB15 by SIEMENS.
USER MANUAL 3RW4037-1BB15 SIEMENS
Data sheet 3RW40 37-1BB15

natural_image
3D rendering of an industrial electrical contactor device with no visible text or symbolsSIRIUS SOFT STARTER, S2, 63A, 37KW/500V, 40 DEGR., AC 400-600V, AC/DC 110-230V, SCREW TERMINALS
| General technical data: | ||
| product brand name SIRIUS | ||
| Product equipment Integrated bypass contact system | Yes | |
| Product feature Thyristors | Yes | |
| Product function | ||
| Intrinsic device protection | Yes | |
| motor overload protection | Yes | |
| Evaluation of thermistor motor protection | No | |
| External reset | Yes | |
| Adjustable current limitation | Yes | |
| Inside-delta circuit | No | |
| Product component Motor brake output No | ||
| Equipment marking acc. to DIN EN 61346-2 Q | ||
| Equipment marking acc. to DIN 40719 extended according to IEC 204-2 acc. to IEC 750 | G | |
| Power Electronics: | ||
| Operating current | ||
| • at 40 °C rated value | A | 63 |
| • at 50 °C rated value | A | 58 |
| • at 60 °C rated value | A | 53 |
| Mechanical power output for three-phase motors | ||
| • at 400 V | ||
| — at standard circuit at 40 °C rated value | W 30 000 | |
| • at 500 V | ||
| — at standard circuit at 40 °C rated value | W 37 000 | |
| Operating frequency rated value Hz 50 ... 60 | ||
| Relative negative tolerance of the operating frequency | % -10 | |
| Relative positive tolerance of the operating frequency % | 10 | |
| Operating voltage at standard circuit rated value V 400 ... 600 | ||
| Relative negative tolerance of the operating voltage at standard circuit | % -15 | |
| Relative positive tolerance of the operating voltage at standard circuit | % | 10 |
| Minimum load [% of IM] % 20 | ||
| Adjustable motor current for motor overload protection minimum rated value | A | 26 |
| Continuous operating current [% of le] at 40 °C % 115 | ||
| Power loss [W] at operating current at 40 °C during operation typical | W | 12 |
| Control electronics: | ||
| Type of voltage of the control supply voltage AC/DC | ||
| Control supply voltage frequency 1 rated value Hz 50 | ||
| Control supply voltage frequency 2 rated value Hz 60 | ||
| Relative negative tolerance of the control supply voltage frequency | % -10 | |
| Relative positive tolerance of the control supply voltage frequency | % | 10 |
| Control supply voltage 1 at AC at 50 Hz V 110 ... 230 | ||
| Control supply voltage 1 at AC at 60 Hz V 110 ... 230 | ||
| Relative negative tolerance of the control supply voltage at AC at 60 Hz | % -15 | |
| Relative positive tolerance of the control supply voltage at AC at 60 Hz | % | 10 |
| Control supply voltage 1 at DC V 110 ... 230 | ||
| Relative negative tolerance of the control supply voltage at DC | % -15 | |
| Relative positive tolerance of the control supply voltage at DC | % | 10 |
| Display version for fault signal red | ||
Mechanical data:
| Size of engine control device S2 | ||
| Width mm 55 | ||
| Height mm 160 | ||
| Depth mm 170 | ||
| Mounting type screw and snap-on mounting | ||
| Mounting position With additional fan: With vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5°tiltable to the front and back Without additional fan:With vertical mounting surface +/-10° rotatable, withvertical mounting surface +/- 10° t | ||
| Required spacing with side-by-side mountingupwards at the side downwards | mm 60mm 30mm 40 | |
| Installation altitude at height above sea level m 5 000 | ||
| Wire length maximum m 300 | ||
| Number of poles for main current circuit 3 | ||
| Connections/ Terminals: | ||
| Type of electrical connection | ||
| • for main current circuit | screw-type terminals | |
| • for auxiliary and control current circuit | screw-type terminals | |
| Number of NC contacts for auxiliary contacts 0 | ||
| Number of NO contacts for auxiliary contacts 2 | ||
| Number of CO contacts for auxiliary contacts 1 | ||
| Type of connectable conductor cross-sections for main contacts for box terminal using the front clamping point | ||
| • solid | 2x (1.5 ... 16 mm ^2 ) | |
| • finely stranded with core end processing | 0.75 ... 25 mm ^2 | |
| • stranded | 0.75 ... 35 mm ^2 | |
| Type of connectable conductor cross-sections for main contacts for box terminal using the back clamping point | ||
| • solid | 2x (1.5 ... 16 mm ^2 ) | |
| • finely stranded with core end processing | 1.5 ... 25 mm ^2 | |
| • stranded | 1.5 ... 35 mm ^2 | |
| Type of connectable conductor cross-sections for main contacts for box terminal using both clamping points | ||
| • solid | 2x (1.5 ... 16 mm ^2 ) | |
| • finely stranded with core end processing | 2x (1.5 ... 16 mm ^2 ) | |
| • stranded | 2x (1.5 ... 25 mm ^2 ) | |
| Type of connectable conductor cross-sections at AWG conductors for main contacts for box terminal | ||
| using the back clamping pointusing the front clamping pointusing both clamping points | 16 ... 218 ... 22x (16 ... 2) | |
| Type of connectable conductor cross-sections for auxiliary contactssolidfinely stranded with core end processing | 2x (0.5 ... 2.5 mm^2 )2x (0.5 ... 1.5 mm^2 ) | |
| Type of connectable conductor cross-sections at AWG conductorsfor auxiliary contactsfor auxiliary contacts finely stranded with core end processing | 2x (20 ... 14)2x (20 ... 16) | |
Ambient conditions:
| Ambient temperature | |
| • during operation | °C -25 ... +60 |
| • during storage | °C -40 ... +80 |
| Derating temperature °C 40 | |
| Protection class IP IP00 |
Certificates/ approvals:
| General Product Approval EMC For use in | hazardous locations | ||||
![]() | ![]() | ![]() | ![]() | ![]() | ![]() |
| CCC | CSA | UL | C-Tick | ATEX | |

| Yielded mechanical performance [hp] for three-phase AC motor | ||
| • at 460/480 V | ||
| — at standard circuit at 50 °C rated value | hp 40 | |
| • at 575/600 V | ||
| — at standard circuit at 50 °C rated value | hp 50 | |
| Contact rating of auxiliary contacts according to UL B300 / R300 | ||
Further information
Simulation Tool for Soft Starters (STS)
https://support.industry.siemens.com/cs/ww/en/view/101494917
Information- and Downloadcenter (Catalogs, Brochures,...)
http://www.siemens.com/industrial-controls/catalogs
Industry Mall (Online ordering system)
http://www.siemens.com/industrymall
Cax online generator
http://support.automation.siemens.com/WW/CAXorder/default.aspx?lang=en&mlfb=3RW4037-1BB15
Service&Support (Manuals, Certificates, Characteristics, FAQs,...)
https://support.industry.siemens.com/cs/ww/en/ps/3RW4037-1BB15
Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...) http://www.automation.siemens.com/bilddb/cax_de.aspx?mlfb=3RW4037-1BB15&lang=en


natural_image
Architectural floor plan showing room layouts and dimension lines (no text or labels)
natural_image
Pure technical line drawing of a rectangular frame with dimension lines and no text or symbols
last modified: 12/18/2016