NUVO Gotham 60/190 - Lighting

Gotham 60/190 - Lighting NUVO - Free user manual and instructions

Find the device manual for free Gotham 60/190 NUVO in PDF.

📄 1 pages English EN Download 💬 AI Question 10 questions ⚙️ Specs
Notice NUVO Gotham 60/190 - page 1
Pick your language and provide your email: we'll send you a specifically translated version.
Product Type Pendant Light
Model Gotham 60/190
Brand NUVO
Dimensions Diameter: 60 cm, Height: adjustable up to 190 cm
Weight 3 kg (approx)
Power Source Hardwired, 120V AC
Light Source Compatible with E26 base bulb (not included)
Max Wattage 60W incandescent or 12W LED
Material Metal shade with glass diffuser
Color Black
Dimmable Yes, when used with a compatible dimmable bulb
Safety Rating UL Listed
Installation Ceiling mount, includes mounting hardware
Included Accessories Mounting bracket, screws, wire connectors, user manual
Maintenance Wipe with a soft dry cloth; do not use harsh chemicals
Certifications cULus listed
Indoor/Outdoor Use Indoor use only
Sloped Ceiling Compatible Yes, up to 45 degrees
Adjustable Height Yes, via cord or chain (cut to fit)

Frequently Asked Questions - Gotham 60/190 NUVO

What type of bulb does the Gotham 60/190 use?
It uses a standard E26 base bulb. The maximum wattage is 60W incandescent or 12W LED.
Is the fixture dimmable?
Yes, it is dimmable when used with a compatible dimmable bulb and a dimmer switch.
Can the height be adjusted?
Yes, the height is adjustable up to 190 cm. The cord or chain can be shortened during installation.
Is this light suitable for outdoor use?
No, it is designed for indoor use only.
How do I clean the fixture?
Wipe with a soft dry cloth. Avoid abrasive cleaners or chemicals.
Can it be installed on a sloped ceiling?
Yes, it is compatible with sloped ceilings up to 45 degrees.
What is the weight of the fixture?
The approximate weight is 3 kg.
Does it come with a warranty?
NUVO offers a limited lifetime warranty against defects.
Are replacement parts available?
Yes, contact NUVO customer support for replacement parts such as shades or mounting hardware.
How do I install the Gotham 60/190?
Installation requires hardwiring to a ceiling junction box. Follow the included manual: connect wires (black to black, white to white, ground to ground), mount the bracket, and attach the fixture.

User questions about Gotham 60/190 NUVO

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Lighting in PDF format for free! Find your manual Gotham 60/190 - NUVO and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. Gotham 60/190 by NUVO.

USER MANUAL Gotham 60/190 NUVO

INSTALLATION AND SAFETY INSTRUCTIONS

FOR YOUR SAFETY

WARNING: BE SURE THE ELECTRICITY TO THE WIRES YOU ARE WORKING ON IS SHUT OFF; EITHER THE FUSE IS REMOVED OR THE CIRCUIT BREAKER IS SHUT OFF.

GENERAL

You don't need special tools to install this fixture. Be sure to follow the steps in the order given. Under no circumstances should a fixture be hung on house electrical wires, nor should a swag type fixture be installed on a ceiling, which contains a radiant type heating system. Read instructions carefully. If you are unclear as to how to proceed, consult a qualified electrician.

NOTE: Proper wiring is essential for the safe operation of this fixture.

FIXTURE ASSEMBLY

Carefully remove the fixture from the carton and check that all parts are included as shown in figure. Be careful not to misplace any of the screws or parts, which are needed to install this fixture.

STEP 2: Thread the nipple (K) into column (L) and the coupling (M).

INSTALLATION

IMPORTANT: Do not attach fixture directly to outlet box.

STEP 1: Thread nut (D) onto nipple (E) so that five threads are exposed above nut (D). Insert lock washer (C) and thread nipple (E) onto mounting bar (A), then secure with the nut (D), secure mounting bar (A) to outlet box with outlet box screws (B).

STEP 2: Thread screw collar (H) onto the nipple (E). Slide screw collar ring (G) and canopy (F) over chain (I). Using two pairs of pliers, open one link of chain (I) and connect it to the fixture loop (J).

STEP 3: Lace wires up through chain (I) and pass wires through holes in screw collar (H). We recommend lacing wire up through every other link of chain (I).

GROUNDING INSTRUCTIONS

STEP 1: The green grounding screw is to be inserted into the hole with two raised dimples provided on the mounting bar. Wrap the ground wire from the fixture (if supplied) and the ground wire from the outlet box (bare metal) or green insulated wire around the green grounding screw on the mounting bar. If uninstalled wire is on the mounting bar, connect the ground wire from the fixture (if supplied) and the outlet box to it using a small wire connector (not supplied).

NOTE: Underwriters Laboratories does not require all fixtures to have ground wires. These fixtures still meet all U. L. specifications.

NEVER CONNECT GROUND WIRE TO BLACK OR WHITE POWER SUPPLY WIRES.

STEP 2: Take note of the color of the wire(s) on your fixture. Identify which group your fixture wire(s) falls into and connect the wires according to the directions below:

GROUP A: Connect to Black House WireGROUP B: Connect to White House Wire
BLACKWHITE
*PARALLEL WIRE (round & smooth)*PARALLEL WIRE (square & ridged)
WHITE OR GREY WITH TRACERWHITE OR GREY WITHOUT TRACER
BROWN GOLD OR BLACK WITHOUT TRACERBROWN, GOLD OR BLACK WITH TRACER

*NOTE: When parallel wire (SPT-I & SPT-2) is used, the tracer wire is square shaped or ridged and the less tracer wire is round in shape or smooth (seen best when viewed from wire end.)

STEP 3: Take your fixture wire(s) from group A and place evenly against the black wire from the outlet box. Do NOT twist wires together before using wire connectors.

STEP 4: Fit a wire connector over the wires and screw the connector clockwise until you feel firmness.

STEP 5: Try gently to pull the connector off the wires. If you can pull the connector off, carefully re-do steps 3 and 4 as above, and check again for a firm connection.

STEP 6: Connect the fixture wire from group B to the white wire from the outlet box in the same manner. Make sure no bare wires can be seen outside wire connectors.

FINAL ASSEMBLY

STEP 1: After wires are connected, tuck them carefully inside outlet box, then secure canopy (F) with screw collar ring (G).

STEP 2: Thread nut (P) onto the nipple (Q) then thread the nipple (Q) into the coupling (N) and secure the nipple (Q) with nut (P).

STEP 3: Raise the column (O) and cap (R) onto the nipple (Q) then secure with finial (S).

STEP 4: Slide the glass shade (U) over the socket (T) and secure with the retaining ring (V).

STEP 5: Install lamps. (Please do not exceed the maximum capacity recommended on the socket.)

CLEANING

To clean, wipe fixture with a soft cloth. Clean glass with a mild soap. Do not use abrasive materials such as scouring pads or powders, steel wool or abrasive paper.